Image not available
Illustrative purposes only
EPP-200-27
AC/DC Open Frame Power Supply (PSU), ITE, 1 Output, 200W @ 10CFM, 140 W, 80V AC to 264V AC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):140W; Power Rating (Forced Cooling):200W @ 10CFM; Input Voltage VAC:80V AC to 264V AC; Power Supply Output Type:Adjustable, Fixed;
- SVHC: No SVHC (27-Jun-2024)
- Product Range: EPP-200 Series
- No. of Outputs: 1 Output
- Output Power Max: 143.1W
- Input Voltage VAC: 80V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 80V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 5.3A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 27VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
- Power Rating (Forced Cooling): 200W @ 10CFM
- Power Rating (Convection Cooling): 140W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 40.43 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- EPP 200 series** 200W Single Output with PFC Function BauarSicherheitbeegelodwacmat geprufto ges g ® cALis ~~4)~~ www.ID 2000000000tuv.com CBCE ## ■ **** - ‧× - ‧ - ‧ - ‧Ⅰ - Ⅱ ## ■ **** - ‧ - ‧ - ‧ - ‧ - - ‧ - ‧ - ‧ - - ‧ - - ‧ - ‧ ## ‧ ## ■ **** ⅠⅡ ## ■ **** TLeb ** ** _File Name:EPP-200-SPEC 2016-03-05_ 200W Single Output with PFC Function ## **- EPP 200 series** ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**10CFM**<br>**10CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**FAN SUPPLY**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>12ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.94/230VAC PF>0.98/115VAC at full load<br>93%<br>93%<br>94%<br>16.5 ~ 19.5V<br>94%<br>26.4 ~ 31.2V<br>94%<br>29.7 ~ 35V<br>52.8 ~ 62.4V<br>1.8A/115VAC 1A/230VAC<br>COLD START 30A/115VAC 60A/230VAC<br>110 ~ 140% rated output power<br>13.2 ~ 15.6V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-30 ~ +70℃(Refer to "Derating Curve")<br>12V@0.5A for driving a fan ; tolerance +15% ~ -15%<br>Protection type : Shut down o/p voltage, re-power on to recover<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>500.2Khrs min. MIL-HDBK-217F (25℃)<br>101.6*50.8*29mm (L*W*H)<br>0.19Kg; 72pcs/14.7Kg/0.82CUFT<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±2.0%<br>±2.5%<br>±1.0%<br>±1.0%<br>±1.0%<br>100mVp-p<br>11.4~12.6V<br>14.3~15.8V<br>22.8~25.2V<br>25.6 ~ 28.4V<br>45.6 ~50.4V<br>100mVp-p<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>15V<br>24V<br>27V<br>48V<br>16.7A<br>11.7A<br>13.4A<br>9.4A<br>8.4A<br>5.9A<br>7.5A<br>5.3A<br>4.2A<br>3A<br>200.4W<br>140.4W<br>141W<br>201W<br>141.6W<br>201.6W<br>143.1W<br>202.5W<br>144W<br>201.6W<br>**EPP-200-12**<br>**EPP-200-15**<br>**EPP-200-24**<br>**EPP-200-27**<br>**EPP-200-48**<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br><br><br><br><br><br> <br> <br><br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A<br>UL60950-1, TUV EN60950-1, IEC60950-1 approved<br>12V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br><0.75mA / 240VAC<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**10CFM**<br>**10CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**FAN SUPPLY**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>12ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.94/230VAC PF>0.98/115VAC at full load<br>93%<br>93%<br>94%<br>16.5 ~ 19.5V<br>94%<br>26.4 ~ 31.2V<br>94%<br>29.7 ~ 35V<br>52.8 ~ 62.4V<br>1.8A/115VAC 1A/230VAC<br>COLD START 30A/115VAC 60A/230VAC<br>110 ~ 140% rated output power<br>13.2 ~ 15.6V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-30 ~ +70℃(Refer to "Derating Curve")<br>12V@0.5A for driving a fan ; tolerance +15% ~ -15%<br>Protection type : Shut down o/p voltage, re-power on to recover<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>500.2Khrs min. MIL-HDBK-217F (25℃)<br>101.6*50.8*29mm (L*W*H)<br>0.19Kg; 72pcs/14.7Kg/0.82CUFT<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±2.0%<br>±2.5%<br>±1.0%<br>±1.0%<br>±1.0%<br>100mVp-p<br>11.4~12.6V<br>14.3~15.8V<br>22.8~25.2V<br>25.6 ~ 28.4V<br>45.6 ~50.4V<br>100mVp-p<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>15V<br>24V<br>27V<br>48V<br>16.7A<br>11.7A<br>13.4A<br>9.4A<br>8.4A<br>5.9A<br>7.5A<br>5.3A<br>4.2A<br>3A<br>200.4W<br>140.4W<br>141W<br>201W<br>141.6W<br>201.6W<br>143.1W<br>202.5W<br>144W<br>201.6W<br>**EPP-200-12**<br>**EPP-200-15**<br>**EPP-200-24**<br>**EPP-200-27**<br>**EPP-200-48**<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br><br><br><br><br><br> <br> <br><br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A<br>UL60950-1, TUV EN60950-1, IEC60950-1 approved<br>12V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br><0.75mA / 240VAC<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|**MODEL**<br>**DC VOLTAGE**<br>**CURRENT**<br>**10CFM**<br>**10CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**OUTPUT**<br>**LINE REGULATION**<br>**VOLTAGE ADJ. RANGE**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME(Typ.)**<br>**VOLTAGE RANGE Note.4**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY(Typ.)**<br>**INPUT**<br>**FUNCTION**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**FAN SUPPLY**<br>**OVER TEMPERATURE**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT(Typ.)**<br>500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load<br>12ms/230VAC 12ms/115VAC at full load<br>80 ~ 264VAC 113 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.94/230VAC PF>0.98/115VAC at full load<br>93%<br>93%<br>94%<br>16.5 ~ 19.5V<br>94%<br>26.4 ~ 31.2V<br>94%<br>29.7 ~ 35V<br>52.8 ~ 62.4V<br>1.8A/115VAC 1A/230VAC<br>COLD START 30A/115VAC 60A/230VAC<br>110 ~ 140% rated output power<br>13.2 ~ 15.6V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>20 ~ 90% RH non-condensing<br>-30 ~ +70℃(Refer to "Derating Curve")<br>12V@0.5A for driving a fan ; tolerance +15% ~ -15%<br>Protection type : Shut down o/p voltage, re-power on to recover<br>-40 ~ +85℃, 10 ~ 95% RH<br>±0.03%/℃(0 ~ 50℃)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>500.2Khrs min. MIL-HDBK-217F (25℃)<br>101.6*50.8*29mm (L*W*H)<br>0.19Kg; 72pcs/14.7Kg/0.82CUFT<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±1.0%<br>±0.5%<br>±0.5%<br>±1.0%<br>±1.0%<br>±0.5%<br>±2.0%<br>±2.5%<br>±1.0%<br>±1.0%<br>±1.0%<br>100mVp-p<br>11.4~12.6V<br>14.3~15.8V<br>22.8~25.2V<br>25.6 ~ 28.4V<br>45.6 ~50.4V<br>100mVp-p<br>150mVp-p<br>150mVp-p<br>200mVp-p<br>15V<br>24V<br>27V<br>48V<br>16.7A<br>11.7A<br>13.4A<br>9.4A<br>8.4A<br>5.9A<br>7.5A<br>5.3A<br>4.2A<br>3A<br>200.4W<br>140.4W<br>141W<br>201W<br>141.6W<br>201.6W<br>143.1W<br>202.5W<br>144W<br>201.6W<br>**EPP-200-12**<br>**EPP-200-15**<br>**EPP-200-24**<br>**EPP-200-27**<br>**EPP-200-48**<br>**SAFETY STANDARDS**<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCENote.3**<br><br><br><br><br><br> <br> <br><br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**PROTECTION**<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A<br>UL60950-1, TUV EN60950-1, IEC60950-1 approved<br>12V<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br><0.75mA / 240VAC<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|**EPP-200-12**|**EPP-200-15**|**EPP-200-24**|**EPP-200-27**|**EPP-200-48**| |---|---|---|---|---|---|---|---|---| |||**DC VOLTAGE**||12V|15V|24V|27V|48V| |||**CURRENT**<br>**10CFM**<br>**10CFM**<br>**Convection**<br>**Convection**<br>**RATED**<br>**POWER**<br>**RIPPLE & NOISE (max.)Note.2**|**10CFM**|16.7A|13.4A|8.4A|7.5A|4.2A| ||||**Convection**|11.7A|9.4A|5.9A|5.3A|3A| ||||**10CFM**|200.4W|201W|201.6W|202.5W|201.6W| ||||**Convection**|140.4W|141W|141.6W|143.1W|144W| |||||100mVp-p|100mVp-p|150mVp-p|150mVp-p|200mVp-p| |||**VOLTAGE ADJ. RANGE**||11.4~12.6V|14.3~15.8V|22.8~25.2V|25.6 ~ 28.4V|45.6 ~50.4V| |||**VOLTAGE TOLERANCENote.3**||±2.0%|±2.5%|±1.0%|±1.0%|±1.0%| |||**LINE REGULATION**||±0.5%|±0.5%|±0.5%|±0.5%|±0.5%| |||**LOAD REGULATION**||±1.0%|±1.0%|±1.0%|±1.0%|±1.0%| |||**SETUP, RISE TIME**||500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load||||| |||**HOLD UP TIME(Typ.)**||12ms/230VAC 12ms/115VAC at full load||||| |||**VOLTAGE RANGE Note.4**||80 ~ 264VAC 113 ~ 370VDC||||| |||**FREQUENCY RANGE**||47 ~ 63Hz||||| |||**POWER FACTOR**||PF>0.94/230VAC PF>0.98/115VAC at full load||||| |||**EFFICIENCY(Typ.)**||93%|93%|94%|94%|94%| |||**AC CURRENT(Typ.)**||1.8A/115VAC 1A/230VAC||||| |||**INRUSH CURRENT(Typ.)**||COLD START 30A/115VAC 60A/230VAC||||| |||**LEAKAGE CURRENT**<br>**OVEROAD**||110 ~ 140% rated output power<br><0.75mA / 240VAC||||| |||**L**<br>||16.5 ~ 19.5V<br>26.4 ~ 31.2V<br>29.7 ~ 35V<br>52.8 ~ 62.4V<br>13.2 ~ 15.6V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed||||| |||**OVER VOLTAGE**||Protection type : Shut down o/p voltage, re-power on to recover||||| |||**OVER TEMPERATURE**||Protection type : Shut down o/p voltage, re-power on to recover||||| |||**FAN SUPPLY**||12V@0.5A for driving a fan ; tolerance +15% ~ -15%||||| |||**WORKING TEMP.**||-30 ~ +70℃(Refer to "Derating Curve")||||| |||**WORKING HUMIDITY**||20 ~ 90% RH non-condensing||||| |||**STORAGE TEMP., HUMIDITY**||-40 ~ +85℃, 10 ~ 95% RH||||| |||**TEMP. COEFFICIENT**||±0.03%/℃(0 ~ 50℃)||||| |||**VIBRATION**||10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes||||| |||**SAFETY STANDARDS**||UL60950-1, TUV EN60950-1, IEC60950-1 approved||||| |||**WITHSTAND VOLTAGE**||I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC||||| |||**ISOLATION RESISTANCE**||I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH||||| |||**EMC EMISSION**||Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3||||| |||**EMC IMMUNITY**||Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A||||| |||**MTBF**||500.2Khrs min. MIL-HDBK-217F (25℃)||||| |||**DIMENSION**||101.6*50.8*29mm (L*W*H)||||| |||**PACKING**<br>0.19Kg; 72pcs/14.7Kg/0.82CUFT<br><br><br><br><br><br> <br> <br>||||||| _File Name:EPP-200-SPEC 2016-03-05_ **- EPP 200 series** ## 200W Single Output with PFC Function **==> picture [79 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram<br>**----- End of picture text -----**<br> **==> picture [495 x 350] intentionally omitted <==** **----- Start of picture text -----**<br> fosc : 65KHz<br>EMI EMI FILTER POWER RECTIFIERS +V<br>I/P FILTER & SWITCHING & -V<br>RECTIFIER FILTER<br>RECTIFIERS<br>& +12V FAN<br>FG FILTER supply<br>DETECTION<br>CIRCUIT<br>O.T.P. O.L.P. CONTROL<br>O.V.P.<br>Derating Curve Output Derating VS Input Voltage<br>100<br>100<br>With 10CFM Fan<br>With 10CFM Fan 90<br>80<br>80<br>70<br>60 Convection 70<br>for 24~48V<br>60<br>40 Convection<br>for 12V~15V<br>50<br>20<br>40<br>-30 0 10 20 30 40 45 50 60 70 (HORIZONTAL) 80 90 115 120 120 140 160 180 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:EPP-200-SPEC 2016-03-05_ **- EPP 200 series** 200W Single Output with PFC Function ## **Mechanical Specification** **==> picture [378 x 321] intentionally omitted <==** **----- Start of picture text -----**<br> Unit:mm<br>FAN<br>※Note 10CFM<br>Air flow<br>direction<br>LED<br>SVR1<br>CN2<br>CN1 1<br>2<br>3<br>2 3<br>1 4<br>FS1 CN101 5<br>2 1 6<br>T4A/250V<br>FS2<br>F4A/250V<br>3.175 95.25<br>101.6<br>4-<br>ψ<br>3.3<br>3.175 50mm<br>50.8 44.45<br>29<br>3 max.<br>**----- End of picture text -----**<br> |AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>JST SVH-21T-P1.1<br>or equivalent<br>or equivalent<br>Terminal<br>: Grounding required|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>JST SVH-21T-P1.1<br>or equivalent<br>or equivalent<br>Terminal<br>: Grounding required|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>JST SVH-21T-P1.1<br>or equivalent<br>or equivalent<br>Terminal<br>: Grounding required|AC Input Connector (CN1) : JST B3P-VH or equivalent<br>Pin No.<br>1<br>2<br>3<br>Assignment<br>AC/L<br>No Pin<br>AC/N<br>Mating Housing<br>JST VHR<br>JST SVH-21T-P1.1<br>or equivalent<br>or equivalent<br>Terminal<br>: Grounding required|DC Output Connector (CN2) : JST B6P-VH or equivalent<br>Pin No.<br>1,2,3<br>4,5,6<br>Assignment<br>-V<br>+V<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>MatingHousing<br>JST PHR-2<br>or equivalent<br>Terminal<br>JSTSPH-002T-P0.5S<br>or equivalent<br>FAN Connector(CN101) :<br>or equivalent<br>JST B2B-PH-K-S<br>Pin No.<br>1<br>2<br>Assignment<br>+12V<br>DC COM|DC Output Connector (CN2) : JST B6P-VH or equivalent<br>Pin No.<br>1,2,3<br>4,5,6<br>Assignment<br>-V<br>+V<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>MatingHousing<br>JST PHR-2<br>or equivalent<br>Terminal<br>JSTSPH-002T-P0.5S<br>or equivalent<br>FAN Connector(CN101) :<br>or equivalent<br>JST B2B-PH-K-S<br>Pin No.<br>1<br>2<br>Assignment<br>+12V<br>DC COM|DC Output Connector (CN2) : JST B6P-VH or equivalent<br>Pin No.<br>1,2,3<br>4,5,6<br>Assignment<br>-V<br>+V<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>MatingHousing<br>JST PHR-2<br>or equivalent<br>Terminal<br>JSTSPH-002T-P0.5S<br>or equivalent<br>FAN Connector(CN101) :<br>or equivalent<br>JST B2B-PH-K-S<br>Pin No.<br>1<br>2<br>Assignment<br>+12V<br>DC COM|DC Output Connector (CN2) : JST B6P-VH or equivalent<br>Pin No.<br>1,2,3<br>4,5,6<br>Assignment<br>-V<br>+V<br>Mating Housing<br>JST VHR<br>or equivalent<br>Terminal<br>JST SVH-21T-P1.1<br>or equivalent<br>MatingHousing<br>JST PHR-2<br>or equivalent<br>Terminal<br>JSTSPH-002T-P0.5S<br>or equivalent<br>FAN Connector(CN101) :<br>or equivalent<br>JST B2B-PH-K-S<br>Pin No.<br>1<br>2<br>Assignment<br>+12V<br>DC COM| |---|---|---|---|---|---|---|---| |Pin No.|Assignment|Mating Housing|Terminal||||| |1|AC/L|JST VHR<br>or equivalent|JST SVH-21T-P1<br>or equivalent||||| |2|No Pin||||||| |3|AC/N||||||| |: Grounding required|||||||| ||||||Assignment|MatingHousing|Terminal| ||||||DC COM|JST PHR-2<br>or equivalent|JSTSPH-002T-P0.5S<br>or equivalent| ||||||+12V||| - ※Note : 1. The FAN supply is designed to serve as the source of the additive external fan for the cooling of the power supply, enabling the full load delivery and assuring the best life span of the product. Please do not use this FAN supply to drive other devices. - 2. EMI Class B for both conducted emission and radiated emission for the power supply, when configured into either Class Ⅰ(with FG) or Class Ⅱ (without FG) system. ## **Installation Manual** Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html _File Name:EPP-200-SPEC 2016-03-05_
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →