AC/DC Enclosed Power Supply (PSU), Ring Lug, ITE & Industrial, 1 Outputs, 500 W, 15 V, 26.67 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EOS POWER
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: EPG500 Series
- No. of Outputs: 1Outputs
- Output Power Max: 500W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 26.67A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 15V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Industrial
| Delivery and price | |
|---|---|
| Units per pack | 42 |
| Price | 337.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
## EPG500 Series 500 W AC-DC Power Supply **Industrial** The EOS Power EPG500 Series of Industrial AC-DC Power Supplies provides up to 500 W of regulated output power over a wide input range of 90–264 VAC. The power supplies are available in six single output voltages ranging from 12 V to 58 V. The EPG500 Series can be used in a broad array of spaceconstrained applications in which minimal power loss and easy thermal management are required. RoHS compliant and CE marked, the power supplies are safety agency certified and meet the latest regulatory requirements. ## **KEY FEATURES & BENEFITS** - New Efficient GaN power technology design - High efficiency up to 94% - Form factor 5 x 3 x 1.6 in (127 x 76.2 x 40.64 mm) - Output power 500 W (Forced air cooling), - 300 W (Convection cooling) - 550 W Peak power (Up to 10 sec) - High power density 20.83 W/inch[3] - Operating temperature - 40°C to +70°C - Thermal shut-down feature - Available with metal enclosures / accessories - IEC / EN / UL 62368 Ed 3.0 - I²C interface communication provision added in future - Over temperature, OV, OC and SC protection - Stand by 5 VDC / PGPF Signal / Remote ON-OFF features (optional) - Fan 12 VDC, 0.5 A output & Remote sense signal ## **APPLICATIONS** - Industrial Process Control / Automation & Monitoring - Test & Measurement / Advertising Signage / Video Walls - Broadcasting / Networking / Telecommunication **belfuse.com** EPG500 Series 2 ## **1. MODEL SELECTION** **==> picture [511 x 285] intentionally omitted <==** **----- Start of picture text -----**<br> MODEL CONNECTION OUTPUT VOLTAGE MIN LOAD MAX LOAD RIPPLE [ 3]<br>NUMBER [ 1] [V] [A] [A] [%]<br>CONVECTION 400 LFM<br>EPG500-1012 [ 2] Screw Terminal 12 0.0 20.0 33.33 2<br>EPG500-1212 [ 2] Ring Lug Terminal 12 0.0 20.0 33.33 2<br>EPG500-1312 [ 2] Molex Connector 12 0.0 20.0 24.00 2<br>EPG500-1015 [ 2] Screw Terminal 15 0.0 16.0 26.67 2<br>EPG500-1215 [ 2] Ring Lug Terminal 15 0.0 16.0 26.67 2<br>EPG500-1315 [ 2] Molex Connector 15 0.0 16.0 24.00 2<br>EPG500-1024 Screw Terminal 24 0.0 12.5 20.83 1<br>EPG500-1224 Ring Lug Terminal 24 0.0 12.5 20.83 1<br>EPG500-1324 Molex Connector 24 0.0 12.5 20.83 1<br>EPG500-1030 Screw Terminal 30 0.0 10.0 16.67 1<br>EPG500-1230 Ring Lug Terminal 30 0.0 10.0 16.67 1<br>EPG500-1330 Molex Connector 30 0.0 10.0 16.67 1<br>EPG500-1048 Screw Terminal 48 0.0 6.25 10.41 1<br>EPG500-1248 Ring Lug Terminal 48 0.0 6.25 10.41 1<br>EPG500-1348 Molex Connector 48 0.0 6.25 10.41 1<br>EPG500-1058 Screw Terminal 58 0.0 5.17 08.62 1<br>EPG500-1258 Ring Lug Terminal 58 0.0 5.17 08.62 1<br>EPG500-1358 Molex Connector 58 0.0 5.17 08.62 1<br>**----- End of picture text -----**<br> - **1** When used in Cover Kit, de-rate output power to 70% under all operating conditions. > **2** See Derating Curves, page 9. > **3** Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. ## **2. MODEL SELECTION EPG500-G** **==> picture [511 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> MODEL CONNECTION OUTPUT VOLTAGE MIN LOAD MAX LOAD RIPPLE [ 3]<br>NUMBER [ 1] [V] [A] [A] [%]<br>CONVECTION 400 LFM<br>EPG500-2412-G [2] Dual Row header 12 0.0 20 33.33 2<br>EPG500-2415-G [2] Dual Row header 15 0.0 16 26.67 2<br>EPG500-2424-G Dual Row header 24 0.0 12.5 20.83 1<br>EPG500-2430-G Dual Row header 30 0.0 10 16.67 1<br>EPG500-2448-G Dual Row header 48 0.0 6.25 10.41 1<br>EPG500-2458-G Dual Row header 58 0.0 5.17 8.62 1<br>**----- End of picture text -----**<br> > **1** When used in Cover Kit, de-rate output power to 70% under all operating conditions. > **2** See Derating Curves, page 9. > **3** Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. **==> picture [71 x 37] intentionally omitted <==** tech.support@psbel.com **belfuse.com** EPG500 Series 3 ## **3. MODEL NUMBER KEY** ## **EPG500 - Z X VV - YYYW - MMMM** **Product Series EPG500** = EOS Power GaN 500 W Series ## **Output Type** **1** = Single output **2** = Standby 5V SB model series ## **Type of Connector** - **0** = Screw terminal **2** = Ring lug connector **3** = Molex connector **4** = Dual Row header (Only for - G) **Accessories Blank** = Open frame **U** = U - channel **L** = L- bracket **CK** = Cover kit **CKF** = Cover kit with Fan (On top / Inside) ## **W-Mounting Hole** **Blank** = 4.55 x 2.55 Inch **G** = 4.68 x 2.68 Inch **Minor o/p variation / Circuit** Any alpha, numberic or alphanumeric character or blank ## **Output Voltage** **12** = 12 V **15** = 15 V **24** = 24 V **30** = 30 V **48** = 48 V **58** = 58 V ## **4. INPUT SPECIFICATIONS** **==> picture [511 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>Input voltage Derate linearly from 100% at 115 VAC to 80% at 90 VAC 4 90 264 VAC<br>Input frequency 47 63 Hz<br>Input current 6.3 A<br>Inrush current 75 A<br>Leakage current 300 µA<br>Touch current 100 µA<br>Power factor 0.95<br>**----- End of picture text -----**<br> > **4** Refer to Derating curves **==> picture [71 x 38] intentionally omitted <==** **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023 EPG500 Series 4 ## **5** ## **5. OUTPUT SPECIFICATIONS** **==> picture [511 x 254] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>Forced air cooling 400 LFM (115 to 264 VAC) 500<br>Output power W<br>Convection cooling (115 to 264 VAC) 300<br>Efficiency At 230 VAC 92 94 %<br>Hold-up time 10 ms<br>Line regulation -0.5 +0.5 %<br>Load regulation -0.5 +0.5 %<br>Output voltage adjustability -3 +3 %<br>Rise time 55 ms<br>Set point tolerance -1 +1 %<br>Max excursion 5%; 75%-100% step load change at 0.1 A / µs<br>Transient response slew rate, 50% duty cycle, 50 Hz<br>Recovery time 5 ms<br>PFC 130<br>Switching frequency kHz<br>PWM 100 200<br>Start up delay 115 / 230 VAC Full Load 2 s<br>Drift After 20 minutes warm-up - 0.2 + 0.2 %<br>Over / Undershoot Turn On / Off 5 %<br>Temperature coefficient 0.02 %/°C<br>**----- End of picture text -----**<br> > **5** Specifications are for nominal input voltage 230 VAC, 25°C unless otherwise stated. ## **6. PROTECTIONS** **==> picture [512 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>Over current protection - V1 Hiccup mode; auto recovery 110 %<br>Over voltage protection Hiccup mode; auto recovery 110 140 %<br>Short circuit protection Hiccup mode; auto recovery<br>**----- End of picture text -----**<br> ## **7. ENVIRONMENTAL SPECIFICATIONS** **==> picture [511 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>Operating temperature -40 to 0°C start-up is guaranteed with spec. deviation [6] -40 +70 °C<br>Storage temperature -40 +85 °C<br>Humidity Relative 5 95 %<br>Operating, RH, non-condensing 16000 ft<br>Altitude<br>Non operating, non-condensing 40000 ft<br>**----- End of picture text -----**<br> > **6** Output ripple can be more than 10 % of the output voltage. **==> picture [71 x 37] intentionally omitted <==** tech.support@psbel.com **belfuse.com** EPG500 Series 5 ## **8. SIGNALS & CONTROLS - EPG500-2XXX Series (Multifunctional card optional)** **==> picture [489 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |PARAMETER|DESCRIPTION / CONDITIONS| |Power Good|Is a TTL signal which goes high after main output reaches 90% of its set value. The delay is 0.1 s to 0.5 s| |Power Fail|The same signal goes low at least 1ms before main output falls to 90% of set value at AC Power off| |Remote on/off|Shorting Pin 3 to Pin 4 enables main output while keeping the Pins open disables main output| |SB output voltage|[7]|5 VDC / 0.3 A @ 40°C, Derate linearly to 0.25 A @ 70°C| **----- End of picture text -----**<br> > **7** Tolerance including set point accuracy, line and load regulation is +/-10 %. Ripple and noise is less than 5 %. ## **9. REMOTE ON / OFF** Figure 1. Remote On / Off diagram (available only for EPG500-2XXX option) **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023 EPG500 Series 6 ## **10. POWER GOOD / POWER FAIL SIGNAL** Figure 2. PG / PF Signal diagram (available only for EPG500-2XXX option) ## **11. VOLTAGE SENSE DRAWING** Figure 3. Voltage sense diagram tech.support@psbel.com **belfuse.com** EPG500 Series 7 ## **12. EMC SPECIFICATIONS** **==> picture [511 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS CLASS / LEVEL / CRITERION<br>Conducted emissions EN 55011 / EN 55032, CISPR22-B, FCC PART15-B Level B<br>Radiated emissions EN 55011 / EN 55032, Level A<br>With external core (King core K5B RC 25x12x15-M or equivalent in input cable) Level B<br>Harmonic current EN 61000-3-2 Class A<br>Fluctuation and Flicker EN 61000-3-3 Compliance<br>ESD immunity EN 61000-4-2 Level 4, Criterion A<br>Radiated field immunity EN 61000-4-3 Level 3, Criterion A<br>Electrical fast transient EN 61000-4-4 Level 3, Criterion A<br>Surge immunity EN 61000-4-5 Level 3, Criterion A<br>Conducted immunity EN 61000-4-6 Level 3, Criterion A<br>Magnetic field immunity EN 61000-4-8 Level 4, Criterion A<br>Voltage dips, interruptions EN 61000-4-11 Criterion A & B<br>**----- End of picture text -----**<br> ## **13. AFETY SPECIFICATIONS** **==> picture [511 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>Safety approvals IEC 62368-1, EN 62368-1<br>Information Technology<br>(Pending) UL 62368-1 & CAN/CSA C22.2 No. 62368-1<br>Equipment protection class Class I<br>Input to Output 4000<br>Isolation Input to Ground 2500 VDC<br>Output to Ground 2500<br>MTBF Telcordia -SR332-issue 3 800 khrs<br>**----- End of picture text -----**<br> ## **14. MECHANICAL SPECIFICATIONS** **==> picture [511 x 76] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>127 x 76.2 x 40.64 mm<br>Dimensions<br>5 x 3 x 1.6 in<br>Weight 450 g<br>Forced air cooling 400 LFM<br>Cooling<br>Convection cooling Natural air flow<br>**----- End of picture text -----**<br> **==> picture [71 x 38] intentionally omitted <==** **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023 EPG500 Series 8 ## **15. CONNECTORS & PIN DESCRIPTION** **==> picture [509 x 279] intentionally omitted <==** **----- Start of picture text -----**<br> CONNECTION PIN PIN DESCRIPTION CONNECTOR MANUFACTURER PN<br>Pin 1 AC LINE<br>Molex: 26-60-4030<br>AC Input J1 Pin 2 NOT FITTED<br>Mating: 09-50-3031; Pins: 08-50-0106<br>Pin 3 AC NEUTRAL<br>6-32 inches Screw Pan HD Vertical<br>Screw terminal Mating: Designed to accept Ring Tongue Terminal<br>AMP: 8-31886-1<br>Molex MPN: Header Molex p/n: 26-60-4080 or equivalent<br>Pin 1,2,3,4 V1 +VE<br>DC Output J2 Molex connector Mating part no: A: Hosuing Molex p/n: 09-50-3081 or equivalent<br>Pin 5,6,7,8 V1 -VE<br>B: Pins Molex p/n: 08-50-0106 or equivalent<br>The DC output terminals are designed to accept a ring-lug<br>Ring Lug<br>terminal. These terminal use 6-32 screw.<br>terminal<br>Ring terminal: Tyco 35148 or KST RV3-4 or equivalent<br>Pin 1 FAN+ AMP: 640456-2<br>Aux Output (Fan) J6<br>Pin 2 FAN- Mating: 640440-2<br>Header 2 POS 2.54MM) p/n: P9102-40-12-1<br>Aux Output Pin 1 +VS Mating part no: CONN RCPT HSNG 2POS CST-100 II<br>J9<br>(Signal) Pin 2 - VS p/n: 1375820 - 2<br>Pins: CONN SOCKET 22-26AWG CRIMP TIN p/n: 1375819-1<br>Pin 1 5 VDC Header 5 POS 2.54MM) p/n: P9102-40-12-1<br>Multifunction Pin 2,3 GND Mating part no: CONN RCPT HSNG 5POS CST-100 II p/n:<br>J10<br>Connector Pin 4 ON / OFF 1375820-5<br>Pin 5 PGPF Pins: CONN SOCKET 22-26AWG CRIMP TIN p/n: 1375819-1<br>Molex: 19705-4301<br>Earth J4<br>Mating: 19003-0001<br>**----- End of picture text -----**<br> ## **16. CONNECTORS & PIN DESCRIPTION FOR EPG500-G** **==> picture [511 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> CONNECTION PIN PIN DESCRIPTION CONNECTOR MANUFACTURER PN<br>Pin 1 AC LINE<br>Molex: 41671-3473<br>AC Input J1 Pin 2 NOT FITTED<br>Mating: 09-50-8031; Pins: 08-50-0106<br>Pin 3 AC NEUTRAL<br>Pin 1,2,3,4 V1 +VE Molex: 172298-1208<br>DC Output J2 Header Dual Row<br>Pin 5,6,7,8 V1 -VE Mating: 172258-3108<br>Pin 1 FAN+ AMP: 640456-2<br>Aux Output (Fan) J6<br>Pin 2 FAN- Mating: 640440-2<br>Pin A1,A2 5 VDC<br>Pin A3,B1 NC<br>Pin A4 +VS<br>Multifunction FCI: 98414-G04-10ULF<br>J10 Pin A5 -VS Header Dual Row<br>Connector Mating part no: FCI 90311-010LF<br>Pin B2,B3 GND<br>Pin B4 PG<br>Pin B5 ON / OFF<br>Molex: 19705-4301<br>Earth J4<br>Mating: 19003-0001<br>**----- End of picture text -----**<br> **==> picture [71 x 37] intentionally omitted <==** tech.support@psbel.com **belfuse.com** EPG500 Series 9 ## **17. DERATING CURVES** Notes: De-rate linearly from 100% at 115 VAC to 80% at 90 VAC Figure 4. Output Power Derating w.r.t. Input Notes: Convection load: 300 W up to 40°C; derate above 40°C @ 1.67% per °C Forced air load for Airflow Option A: 500 W up to 40°C derate above 40°C @ 1.67 % per °C Forced air load for Airflow Option B: 450 W up to 40°C derate above 40°C @ 1.67 % per °C Figure 5. Power Derating of 24 V, 30 V, 48 V & 58 V models (Open frame / L channel / U bracket options) **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023 EPG500 Series 10 Notes: Convection load: 240 W up to 40°C; derate above 40°C @ 1.67% per °C Forced air load for Airflow Option A: 400 W up to 40°C derate above 40°C @ 1.67 % per °C Forced air load for Airflow Option B: 350 W up to 40°C derate above 40°C @ 1.67 % per °C Figure 6. Power Derating of 12 V & 15 V models (Open frame / L channel / U bracket options) Notes: Convection load for 24 V to 58 V: 210 W up to 40°C; derate above 40°C @ 1.67% per °C Convection load for 12 V,15 V: 168 W up to 40°C derate above 40 °C @ 1.67 % per °C Figure 7. Power Derating of 12 V to 58 V models (Cove kit option) tech.support@psbel.com **belfuse.com** EPG500 Series 11 ## **18. MECANICAL DRAWINGS** **EPG500-1XXX WITHOUT MULTI CARD** Figure 8. Mechanical Drawing – EPG500-1XXX Without Multi card **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023 EPG500 Series 12 ## **EPG500-2XXX WITH MULTI CARD** Figure 9. Mechanical Drawing – EPG500-2XXX With Multi card tech.support@psbel.com **belfuse.com** EPG500 Series ## **EPG500-1XXX L** Figure 10. Mechanical Drawing – EPG500-1XXX L **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023 EPG500 Series 14 **EPG500-1XXX U** Figure 11. Mechanical Drawing – EPG500-1XXX U tech.support@psbel.com **belfuse.com** EPG500 Series ## **EPG500-1XXX-COVER KIT** Figure 12. Mechanical Drawing – EPG500-1XXX Cover Kit **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023 EPG500 Series 16 ## **EPG500-1XXX-COVER KIT WITH FAN** Figure 13. Mechanical Drawing – EPG500-1XXX Cover Kit with Fan tech.support@psbel.com **belfuse.com** EPG500 Series ## **EPG500-2XXX L** Figure 14. Mechanical Drawing – EPG500-2XXX L **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023 EPG500 Series 18 **EPG500-2XXX U** Figure 15. Mechanical Drawing – EPG500-2XXX U tech.support@psbel.com **belfuse.com** EPG500 Series ## **EPG500-24XX G** ## Figure 16. Mechanical Drawing – EPG500-24XX G **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com** © 2023 Bel Fuse Inc. EPG500 Series_1 31 May 2023
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →