Image not available
Illustrative purposes only
EPBAP86
TB, POWER DISTRIBUTION, 2POLE, 14AWG
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MARATHON SPECIAL PRODUCTS
- Product type: Power Distribution Blocks
- Ra; TB, POWER DISTRIBUTION, 2POLE, 14AWG; Rated Current:760A; Rated Voltage:600V; No. of Poles:2 Pole; Line Side Connections Per Pole:2; Line Side Connection Method:Screw; Line Side
- SVHC: No SVHC (21-Jan-2025)
- No. of Poles: 2 Pole
- Product Range: -
- Rated Current: 760A
- Rated Voltage: 600V
- Line Side Wire Size Max: 4AWG
- Load Side Wire Size Max: 4AWG
- Line Side Connection Method: Screw
- Load Side Connection Method: Screw
- Line Side Connections Per Pole: 2
- Load Side Connections Per Pole: 12
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 154.17 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Product Data Sheet EPBAP86 Power Distribution Block, Enclosed ## **760 Amps 600 Volts AC/DC** ## Wire Range - Line: (2) 500 kcmil - #4 AWG - Load: (12) #4 - #14 AWG ## Electrical Ratings - 760 Amps (675A CSA) - 600V per UL 1059 & CSA 22.2 No.158, class B & C requirements - Short circuit current ratings (SCCR): See SCCR section below for specifications. - CU7AL - 75°C connector terminal rating with copper or aluminum wire - Touch protection: IP-20 (IEC 60529) - Factory & Field Wiring ## Agency Compliance - UL Listed, Investigated to UL 1953, File QPQS.E309401. 760A - CSA - certifed to C22.2 No. 158, File No. LR19766 (wire classes B & C only) 675A - CE compliant to IEC 60947-7-1 (Pending) ## Material Information - Insulator base: - Thermoplastic - Flammability rating of insulator base UL94V0 - Insulator base temperature rating: -40°C to 125°C (UL RTI) - Connector: plated aluminum - Terminal set screws: plated steel - Connector mounting screws: plated steel - RoHS compliant A Regal Brand **1** **www.marathonsp.com** ## **Termination Specifications** |**Line Side**|**Wire Size**<br>**(CU Stranded)**|**Torque**<br>~~ee~~|**Wires /**<br>**Terminal**<br>~~ee~~|**Wire Class (UL)1**| |---|---|---|---|---| ||500 kcmil - 2 AWG<br>~~ae~~|42.3 N·m (375 lbf·in)<br>~~ae~~<br>~~ee~~<br>~~ee~~|1<br>~~ae~~<br>~~ee~~<br>~~ee~~|B, C<br>~~ae~~| ||350 kcmil - 2 AWG<br>~~ee~~|42.3 N·m (375 lbf·in)<br>~~ee ~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~<br>~~es~~|B, C, G, H, I<br>~~ee~~| ||4 AWG<br>~~ee~~|42.3 N·m (375 lbf·in)<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~es~~|B, C<br>~~ee~~| - Aluminum stranded wire range: 3/0 - 6 AWG - Wire strip length: 1-7/16 in. (36.5mm) - IP-20 protection: - With break-away tab - 3/0-4 AWG - Without break-away tab - 500 kcmil - 4/0 AWG - No wire present-remove tab and use plug (Catalog No. EPB-Plug-500) - Terminal screw drive: 5/16 inch hex |**Load Side**|**Wire Size**<br>**(CU Stranded)**|**Torque**|**Wires /**<br>**Terminal**|**Wire Class (UL)1**| |---|---|---|---|---| |~~**|**~~|4<br>~~a~~<br>~~ee~~|4 N·m (35 lbf·in)<br>~~a~~|1<br>~~a~~|B, C<br>~~a~~| ||6 - 8<br>~~ee~~|4 N·m (35 lbf·in)|1|B, C, G, H, I| ||10<br>~~ee~~<br>~~a~~~~**|**~~|4 N·m (35 lbf·in)|1 - 2|B, C, I| ||12 - 14<br>~~**|**~~|4 N·m (35 lbf·in)|1 - 2|I| ||||1 - 4<br>~~sf~~|B, C<br>~~sf~~| - Solid copper wire range: #10 - 14 - Aluminum wire range: #4 - #6 AWG - Wire strip length: - top row: 1-3/16 in. (21mm) - bottom row: 1-1/4 in. (32mm) - Terminal screw drive: 1/8 inch hex drive - IP-20 protection: 4 - 14 1 For information on copper stranded wire classes please reference: http://www.marathonsp.com/CatalogPDFs/Flexible-Stranded-Wire.pdf PDS 0499 REV-B 03/08/17 **2** **www.marathonsp.com** ## **Short Circuit Current Ratings (SCCR)** - The suitable conductor ranges are limited to the table values only for achieving the SCCR in excess of the default rating of 10,000A. - Other conductor combinations within the “Terminal Specifications” noted are suitable for achieving a SCCR of 10,000A (the default rating of terminal blocks). - Enclosure size – Investigated with a minimum 16X12X6 enclosure. Use in smaller enclosures is subject to end use evaluation. ## SCCR With Fuses |Wire<br>Class|Suitable<br>Conductors|Suitable<br>Conductors|Max Overcurrent ProtectionFuseRequired<br>AmpRating/ Class|Max Overcurrent ProtectionFuseRequired<br>AmpRating/ Class|Max Overcurrent ProtectionFuseRequired<br>AmpRating/ Class|Max Overcurrent ProtectionFuseRequired<br>AmpRating/ Class|Max Overcurrent ProtectionFuseRequired<br>AmpRating/ Class|Max Overcurrent ProtectionFuseRequired<br>AmpRating/ Class|SCCR RMS<br>Sym. Amps<br>600V. Max| |---|---|---|---|---|---|---|---|---|---| ||Line|Load|J|T|RK1|RK5|G|CC|| |B,C|500-4|4-10|350|350|200|100|60|30|100,000| |G,H,I|350-4|6-10|350|350|200|100|60|30|100,000| |(*)|500 - 6|4 - 14|None||||||10,000| * Any wire class evaluated (see terminal specification section) ## **Installation & Accessories** - Mounting (Panel) - For use with 1/4” (6 mm) fasteners. - Terminal Allen wrench sizes: - Line side 5/16 inch hex drive - Load side 1/8 inch hex drive PDS 0499 REV-B 03/08/17 **3** **www.marathonsp.com** ## **Drawing** PDS 0499 REV-B 03/08/17 **4** **www.marathonsp.com**
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →