EPBAP45
ENCLOSED POWER DISTRIBUTION BLOCK, 4 POSITION, 14-3/0AWG
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MARATHON SPECIAL PRODUCTS
- Product type: Power Distribution Blocks
- Rated Current:200A; Rated Voltage:600V; No. of Poles:5 Pole; Line Side Connections Per Pole:1; Line Side Connection Method:Screw; Line Side Wi 47T4542
- SVHC: No SVHC (21-Jan-2025)
- No. of Poles: 5 Pole
- Product Range: EPB Series
- Rated Current: 200A
- Rated Voltage: 600V
- Line Side Wire Size Max: 000AWG
- Load Side Wire Size Max: 2AWG
- Line Side Connection Method: Screw
- Load Side Connection Method: Screw
- Line Side Connections Per Pole: 1
- Load Side Connections Per Pole: 4
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 78.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Product Data Sheet EPBAP45 Power Distribution Block ## 200 Amps 600 Volts AC/DC ## Wire Range - Line: (1) 3/0 - #14 AWG (70 mm[2] - 2.5 mm[2] ) - Load: (4) #2 - #14 AWG (25 mm[2] - 2.5 mm[2] ) ## Electrical Ratings - 200 Amps - 600V per UL 1953 & CSA 22.2 No.158, class B & C requirements - 1000 V AC/DC per IEC 60947-7-1 (CE) - Short circuit current ratings (SCCR): See SCCR section below for specifications. - CU7AL - 75°C connector terminal rating with copper or aluminum wire - Touch protection: IP-20 (IEC 60529) - Factory & Field Wiring ## Agency Compliance - UL Listed, Investigated to UL 1953, File QPQS.E309401 - CSA - certifed to C22.2 No. 158, File No. LR19766 (Copper wire only, Class B,C) - CE compliant to IEC 60947-7-1 ## Material Information - Insulator base: - Thermoplastic - Flammability rating of insulator base UL94V0 - Insulator base temperature rating: -40°C to 125°C (UL RTI) - Connector: aluminum, tin plated - Terminal set screws: steel, nickel plated - Connector mounting screws: steel, zinc plated - RoHS compliant A Regal Brand 1 www.marathonsp.com ## Termination Specifications |Termination Specificationspecificationsecifications|Termination Specificationspecificationsecifications|Termination Specificationspecificationsecifications| |---|---|---| |Termination Specificationspecificationsecifications<br>Line Side<br>Wire Size<br>(CU Stranded)<br>Torque<br>Wires /<br>Terminal<br>Wire Class (UL)1<br>3/0<br>20.3 N·m<br>(180 lbf·in)<br>1<br>B, C<br>2/0 - 2<br>20.3 N·m<br>(180 lbf·in)<br>1<br>B, C, G, H, I (DLO)<br>4<br>20.3 N·m<br>(180 lbf·in)<br>1<br>B, C, G, H, I (DLO)<br>4<br>20.3 N·m<br>(180 lbf·in)<br>1 - 2<br>B, C<br>~~esee~~<br>~~ee~~<br>(~~Oe~~<br>~~eee~~<br>~~ee~~||| |||6 - 8<br>20.3 N·m<br>(180 lbf·in)<br>1 - 2<br>B, C, G, H, I (DLO)<br>~~ee~~| |||10 - 14<br>5.6 N·m (50 lbf·in)<br>1 - 2<br>B, C, I (DLO)<br>~~ee~~| ||•|Aluminum stranded wire range: 3/0 - 6 AWG| ||•|Copper solid wire range: 10 - 14 AWG| ||•|Wire strip length: 7/8 in. (18mm)| ||•|IP-20 protection: 3/0 - 2| ||•|Terminal screw drive: 6 mm. hex| |Load Side<br>Wire Size<br>(CU Stranded)<br>Torque<br>Wires /<br>Terminal<br>Wire Class (UL)1<br>2<br>5.7 N·m (50 lbf·in)<br>1<br>B, C<br>4 - 6<br>5.7 N·m (50 lbf·in)<br>1<br>B, C, G, H, I (DLO)<br>8<br>5.7 N·m (50 lbf·in)<br>1 - 2<br>B, C, G, H, I (DLO)<br>10<br>4.5 N·m (40 lbf·in)<br>1 - 2<br>B, C, I (DLO)<br>12 - 14<br>4.5 N·m (40 lbf·in)<br>1 - 4<br>B, C, I (DLO)<br>•<br>Aluminum stranded wire range: 2 - 6 AWG<br>~~esre~~<br>~~re~~<br>59 ~~Ff~~<br>~~re~~<br>~~es~~||| - Copper solid wire range: 10 - 14 AWG - Wire strip length: 11/16 in. (17mm) - IP-20 protection: 2 - 14 - Terminal screw drive: 4 mm. hex 1 For information on copper stranded wire classes please visit: http://www.marathonsp.com/CatalogPDFs/Flexible-Stranded-Wire.php PDS 0419 REV-G 12/19/17 2 www.marathonsp.com ## Short Circuit Current Ratings (SCCR) - The suitable conductor ranges are limited to the table values only for achieving the SCCR in excess of the default rating of 10,000A. - Other conductor combinations within the “Terminal Specifications” noted are suitable for achieving a SCCR of 10,000A (the default rating of terminal blocks). - Enclosure size – Investigated with a minimum 16X12X6 enclosure. Use in smaller enclosures is subject to end use evaluation. SCCR With Fuses |Wire<br>Class<br>~~EEE~~|Suitable<br>Conductors<br>~~EEE~~|Suitable<br>Conductors<br>~~EEE~~|Max Overcurrent Protection Fuse Required<br>AmpRating/ Class<br>~~EEE~~|Max Overcurrent Protection Fuse Required<br>AmpRating/ Class<br>~~EEE~~|Max Overcurrent Protection Fuse Required<br>AmpRating/ Class<br>~~EEE~~|Max Overcurrent Protection Fuse Required<br>AmpRating/ Class<br>~~EEE~~|Max Overcurrent Protection Fuse Required<br>AmpRating/ Class<br>~~EEE~~|Max Overcurrent Protection Fuse Required<br>AmpRating/ Class<br>~~EEE~~|SCCR RMS<br>Sym. Amps<br>600V. Max<br>~~EEE~~| |---|---|---|---|---|---|---|---|---|---| ||Line<br>~~EEE~~|Load<br>~~EEE~~|J<br>~~EEE~~|T<br>~~EEE~~|RK1<br>~~EEE~~|RK5<br>~~EEE~~|G<br>~~EEE~~|CC<br>~~EEE~~|| |B,C<br>~~Pe~~<br>~~FR~~|3/0 - 8<br>~~Pe~~<br>~~ee~~|2 - 8<br>~~ee~~<br>~~ee~~|225<br>~~ee ee~~|225<br>~~ee~~|200<br>~~ee~~|60|60|30|100,000| |B,C<br>~~FR~~<br>~~a~~|3/0 - 8<br>~~ee~~<br>|8 - 14<br>~~ee~~|100|110|100|30|60|30<br>~~ee~~|100,000<br>~~ee~~| |B, C<br>~~FR~~<br>~~a~~<br>~~a~~<br>~~a~~|3/0 - 10<br>~~ee~~<br>~~ee~~<br>~~a~~<br>|2 - 14<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>|60<br>~~ee~~<br>~~ee~~<br>|60<br>~~ee~~<br>|30<br>~~ee~~<br>~~ee~~<br>|-<br>~~ee~~<br>~~ee~~<br>|50<br>~~ee~~<br>~~ee~~<br>|30<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>|100,000<br>~~ee~~<br>~~ee~~<br>~~eee~~<br>| |B,C<br>~~a ~~<br>~~a~~<br>~~a~~|(1)8<br> ~~a~~<br>~~a~~|(2)14<br>~~ee~~<br>~~ee~~|225<br>~~ee~~<br>~~ee~~|225<br>~~ee~~|100<br>~~ee~~<br>~~ee~~|60<br>~~ee~~<br>~~ee~~|60<br>~~ee~~<br>~~ee~~|30<br>~~ee ~~<br>~~ee~~<br>~~ee~~|100,000<br> ~~ee~~<br>~~eee~~<br>~~ee~~| |G,H,I<br> <br>~~a ~~<br>~~a~~<br>~~a~~|2/0 - 8<br> ~~a~~<br> ~~a~~<br>~~ee~~|4 - 8<br>~~ee~~<br>~~ee~~<br>~~ee~~|225<br>~~ee~~<br>~~ee~~<br>~~ee~~|225<br>~~ee~~<br>~~ee~~|200<br>~~ee~~<br>~~ee~~<br>~~ee~~|60<br>~~ee~~<br>~~ee~~|60<br>~~ee ~~<br>~~ee~~|30<br> ~~ee ~~<br>~~ee~~|100,000<br> ~~eee~~<br>~~ee~~| |G,H,I<br> <br>~~a~~<br>~~a~~|2/0 - 8<br> ~~a ~~<br>~~ee~~|8 - 12<br> ~~ee~~<br>~~ee~~|100<br>~~ee ~~<br>~~ee~~|110<br> ~~ee~~<br>~~ee~~|100<br>~~ee ~~<br>~~ee~~|30<br> ~~ee ~~|60<br> ~~ee ~~|30<br> ~~ee ~~|100,000<br> ~~ee~~| |(*)<br>~~a~~|3/0 - 14<br>~~ee ~~<br>~~a~~|2 - 14<br> ~~ee~~<br>~~ee~~|None<br>~~ee ee~~<br>~~ee~~||||||10,000<br>~~ee~~| * Any wire class evaluated (see terminal specification section) ## SCCR With Circuit Breakers |Wire<br>Class|Suitable<br>Conductors|Suitable<br>Conductors|Overcurrent Protection Circuit Required|Overcurrent Protection Circuit Required|Overcurrent Protection Circuit Required|Overcurrent Protection Circuit Required|Voltage AC<br>Max| |---|---|---|---|---|---|---|---| ||Line|Load|Manufacturer|Type|Max Amperage|SCCR RMS<br>sym AMPs|| |B, C|3/0 - 8|2 - 12|Allen Bradley|140G-J6<br>140G-J0<br>140G-J15<br>140MG-J8|250|65kA|480| |B, C|3/0 - 4|2 - 10|Square D|JDL36250|250|18kA|480| |||||JGL36250|250|35kA|| |||||JJL36250|250|65kA|| |||||JLL36250|250|65kA|| PDS 0419 REV-G 12/19/17 3 www.marathonsp.com ## Installation & Accessories - Mounting (Panel): - For use with M6 or #10 fastener. - Mounting torque to be determined in end use application not to exceed 30 lbf·in (3.4 N·m). - Marker cards: - White plastic inserts: EPB Marker Card - Allen wrenches (6mm): - 4 mm 6 mm - • S & K tools 45954 45956 • Snap-on tools FAML4E FAML6E • MAC tools XDLS4MM XDLS6MM • McMaster Carr 8367A22 8367A24 • Armstrong 38-709 38-711 ## Drawing PDS 0419 REV-G 12/19/17 4 www.marathonsp.com
Updated at April 27, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →