Image not available
Illustrative purposes only
ENP-360-24
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 359 W, 24 VDC, 13 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- No. of Outputs:1Outputs; Output Power Max:359W; Output Voltage - Output 1:24V; Output Current - Output 1:13A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - Outp
- SVHC: No SVHC (25-Jun-2025)
- Product Range: ENP-360 Series
- No. of Outputs: 1Outputs
- Output Power Max: 359W
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 13A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 97.59 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- ENP 360 series** 360W Level Ⅵ Desktop Type Power Supply ## ■ ## ■ ## Ⅵ ## ■ > ℃ ~+70 ℃ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:ENP-360-SPEC 2018-05-07_ **- ENP 360 series** 360W Level Ⅵ Desktop Type Power Supply **- series** C **e** eeeeeeeeeeeeeeeeeeeeeeee reer reer reer reer r eee eee ee ~~ee~~ ## **SPECIFICATION** **MODEL** |**ENP-360-24**<br>**ENP-360-48**<br>**ENP-360-12**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>**SETUP, RISE TIME**<br>**Note.7**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.8**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**NO LOAD POWER CONSUMPTION**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**SHORT CIRCUIT**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>27.6V<br>55.2V<br>13.8V<br>13A<br>6.5A<br>26A<br>150mVp-p<br>350mVp-p<br>150mVp-p<br>11.5 ~ 15V<br>23.5 ~ 30V<br>47.5 ~ 58.8V<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±0.5%<br>±2.0%<br>1000ms, 100ms at full load<br>20ms at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.95/230VAC at full load<br>93%<br>94%<br>91%<br>COLD START 60A at 230VAC<br><3.5mA / 240VAC<br><0.5W<br>Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with<br>auto-recovery after the peak load condition is removed<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>31 ~ 36.5V<br>62.1 ~ 72.9V<br>15.5 ~ 18.2V<br>Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>IEC60950-1, UL60950-1 EAC TP TC 004 approved<br>,<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>147.5K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>192*178*45.5mm (L*W*H)<br>1.5Kg; 10pcs/16Kg /1.38CUFT<br>3.8A/115VAC 1.9A/230VAC<br>**AC CURRENT (Typ.)**<br>16.3A<br>8.2A<br>32.6A<br>359W<br>450W<br>359W<br>453W<br>359W<br>450W<br>0 ~ 13A<br>0 ~ 6.5A<br>0 ~ 26A<br>**CURRENT**<br>**WATTAGE**<br>**PEAK**<br>**Note.2**<br>**PEAK**<br>**Note.2**<br>**RATED**<br>**RATED**<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 2, 3V/m<br>Level 2, 1KV<br>Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth<br>Level 2, 3Vrms<br>Level 1, 1A/m<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>-----<br>-----<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance : includes set up tolerance, line regulation and load regulation.<br>5. Line regulation is measured from low line to high line at rated load.<br>6. Load regulation is measured from 0% to 100% rated load.<br>7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.<br>8. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>℃<br>℃<br>2. Peak current or peak power up to 3 seconds is provided.<br>9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>10. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**ENP-360-24**<br>**ENP-360-48**<br>**ENP-360-12**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>**SETUP, RISE TIME**<br>**Note.7**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.8**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**NO LOAD POWER CONSUMPTION**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**SHORT CIRCUIT**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>27.6V<br>55.2V<br>13.8V<br>13A<br>6.5A<br>26A<br>150mVp-p<br>350mVp-p<br>150mVp-p<br>11.5 ~ 15V<br>23.5 ~ 30V<br>47.5 ~ 58.8V<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±0.5%<br>±2.0%<br>1000ms, 100ms at full load<br>20ms at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.95/230VAC at full load<br>93%<br>94%<br>91%<br>COLD START 60A at 230VAC<br><3.5mA / 240VAC<br><0.5W<br>Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with<br>auto-recovery after the peak load condition is removed<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>31 ~ 36.5V<br>62.1 ~ 72.9V<br>15.5 ~ 18.2V<br>Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>IEC60950-1, UL60950-1 EAC TP TC 004 approved<br>,<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>147.5K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>192*178*45.5mm (L*W*H)<br>1.5Kg; 10pcs/16Kg /1.38CUFT<br>3.8A/115VAC 1.9A/230VAC<br>**AC CURRENT (Typ.)**<br>16.3A<br>8.2A<br>32.6A<br>359W<br>450W<br>359W<br>453W<br>359W<br>450W<br>0 ~ 13A<br>0 ~ 6.5A<br>0 ~ 26A<br>**CURRENT**<br>**WATTAGE**<br>**PEAK**<br>**Note.2**<br>**PEAK**<br>**Note.2**<br>**RATED**<br>**RATED**<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 2, 3V/m<br>Level 2, 1KV<br>Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth<br>Level 2, 3Vrms<br>Level 1, 1A/m<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>-----<br>-----<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance : includes set up tolerance, line regulation and load regulation.<br>5. Line regulation is measured from low line to high line at rated load.<br>6. Load regulation is measured from 0% to 100% rated load.<br>7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.<br>8. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>℃<br>℃<br>2. Peak current or peak power up to 3 seconds is provided.<br>9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>10. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**ENP-360-24**<br>**ENP-360-48**<br>**ENP-360-12**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RIPPLE & NOISE (max.) Note.3**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**VOLTAGE TOLERANCE Note.4**<br>**LINE REGULATION**<br>**Note.5**<br>**LOAD REGULATION**<br>**Note.6**<br>**SETUP, RISE TIME**<br>**Note.7**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.8**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**NO LOAD POWER CONSUMPTION**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**SHORT CIRCUIT**<br>**OVER VOLTAGE**<br>**PROTECTION**<br>27.6V<br>55.2V<br>13.8V<br>13A<br>6.5A<br>26A<br>150mVp-p<br>350mVp-p<br>150mVp-p<br>11.5 ~ 15V<br>23.5 ~ 30V<br>47.5 ~ 58.8V<br>±1.0%<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>±0.5%<br>±1.0%<br>±0.5%<br>±2.0%<br>1000ms, 100ms at full load<br>20ms at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.95/230VAC at full load<br>93%<br>94%<br>91%<br>COLD START 60A at 230VAC<br><3.5mA / 240VAC<br><0.5W<br>Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with<br>auto-recovery after the peak load condition is removed<br>Protection type : Constant current limiting, recovers automatically after fault condition is removed<br>31 ~ 36.5V<br>62.1 ~ 72.9V<br>15.5 ~ 18.2V<br>Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>IEC60950-1, UL60950-1 EAC TP TC 004 approved<br>,<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>147.5K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>192*178*45.5mm (L*W*H)<br>1.5Kg; 10pcs/16Kg /1.38CUFT<br>3.8A/115VAC 1.9A/230VAC<br>**AC CURRENT (Typ.)**<br>16.3A<br>8.2A<br>32.6A<br>359W<br>450W<br>359W<br>453W<br>359W<br>450W<br>0 ~ 13A<br>0 ~ 6.5A<br>0 ~ 26A<br>**CURRENT**<br>**WATTAGE**<br>**PEAK**<br>**Note.2**<br>**PEAK**<br>**Note.2**<br>**RATED**<br>**RATED**<br>**SAFETY &**<br>**EMC**<br>**(Note 9)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024<br>**Standard**<br>**Standard**<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 2, 3V/m<br>Level 2, 1KV<br>Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth<br>Level 2, 3Vrms<br>Level 1, 1A/m<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>-----<br>-----<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance : includes set up tolerance, line regulation and load regulation.<br>5. Line regulation is measured from low line to high line at rated load.<br>6. Load regulation is measured from 0% to 100% rated load.<br>7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.<br>8. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>℃<br>℃<br>2. Peak current or peak power up to 3 seconds is provided.<br>9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>10. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**ENP-360-12**|**ENP-360-24**|**ENP-360-48**| |---|---|---|---|---|---| ||**DC VOLTAGE**||13.8V|27.6V|55.2V| ||**RATED CURRENT**||26A|13A|6.5A| ||**CURRENT**|**PEAK**<br>**Note.2**<br>**RATED**|32.6A<br>0 ~ 26A|16.3A<br>0 ~ 13A|8.2A<br>0 ~ 6.5A| ||**WATTAGE**|**PEAK**<br>**Note.2**<br>**RATED**|359W<br>450W|359W<br>450W|359W<br>453W| ||**RIPPLE & NOISE (max.) Note.3**||150mVp-p|150mVp-p|350mVp-p| ||**VOLTAGE ADJ. RANGE**||11.5 ~ 15V|23.5 ~ 30V|47.5 ~ 58.8V| ||**VOLTAGE TOLERANCE Note.4**||±1.0%|±1.0%|±1.0%| ||**LINE REGULATION**<br>**Note.5**||±0.5%|±0.5%|±0.5%| ||**LOAD REGULATION**<br>**Note.6**||±2.0%|±1.0%|±0.5%| ||**SETUP, RISE TIME**<br>**Note.7**||1000ms, 100ms at full load||| ||**HOLD UP TIME (Typ.)**||20ms at full load||| ||**VOLTAGE RANGE**<br>**Note.8**||90 ~ 264VAC 127 ~ 370VDC||| ||**FREQUENCY RANGE**||47 ~ 63Hz||| ||**POWER FACTOR (Typ.)**||PF>0.98/115VAC, PF>0.95/230VAC at full load||| ||**EFFICIENCY (Typ.)**||91%|93%|94%| ||**AC CURRENT (Typ.)**||3.8A/115VAC 1.9A/230VAC||| ||**INRUSH CURRENT (Typ.)**||COLD START 60A at 230VAC||| ||**LEAKAGE CURRENT**||<3.5mA / 240VAC||| ||**NO LOAD POWER CONSUMPTION**||<0.5W||| ||**SHORT CIRCUIT**||Protection type : Constant current limiting, recovers automatically after fault condition is removed||| ||**OVERLOAD**||Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with<br>auto-recovery after the peak load condition is removed<br>Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed||| ||**OVER VOLTAGE**||31 ~ 36.5V<br>62.1 ~ 72.9V<br>15.5 ~ 18.2V<br>Protection type : Shut down o/p voltage, re-power on to recover||| ||**OVER TEMPERATURE**||Shut down O/P voltage, recovers automatically after temperature goes down||| ||**WORKING TEMP.**||-30 ~ +70<br>(Refer to "Derating Curve")<br>℃||| ||**WORKING HUMIDITY**||20 ~ 95% RH non-condensing||| ||**STORAGE TEMP., HUMIDITY**||-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃||| ||**TEMP. COEFFICIENT**||±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)||| ||**VIBRATION**||10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes||| ||**SAFETY STANDARDS**||IEC60950-1, UL60950-1 EAC TP TC 004 approved<br>,||| ||**WITHSTAND VOLTAGE**||I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC||| ||**ISOLATION RESISTANCE**||I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**||**Parameter**|**Standard**|**Test Level / Note**| ||||Conducted|EN55032 (CISPR32) / FCC PART15 (CISPR22)|Class B| ||||Radiated|EN55032 (CISPR32) / FCC PART15 (CISPR22)|Class B| ||||Harmonic Current|EN61000-3-2|-----| ||||Voltage Flicker|EN61000-3-3|-----| ||||EN55024||| ||||**Parameter**|**Standard**|**Test Level / Note**| ||||ESD|EN61000-4-2|Level 3, 8KV air ; Level 2, 4KV contact| ||||Radiated|EN61000-4-3|Level 2, 3V/m| ||||EFT / Burst|EN61000-4-4|Level 2, 1KV| ||||Surge|EN61000-4-5|Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth| ||||Conducted|EN61000-4-6|Level 2, 3Vrms| ||||Magnetic Field|EN61000-4-8|Level 1, 1A/m| ||||Voltage Dips and Interruptions|EN61000-4-11|>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| ||||147.5K hrs min. MIL-HDBK-217F (25<br>)<br>℃||| ||**DIMENSION**||192*178*45.5mm (L*W*H)||| ||**PACKING**<br>1.5Kg; 10pcs/16Kg /1.38CUFT<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance : includes set up tolerance, line regulation and load regulation.<br>5. Line regulation is measured from low line to high line at rated load.<br>6. Load regulation is measured from 0% to 100% rated load.<br>7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.<br>8. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>℃<br>℃<br>2. Peak current or peak power up to 3 seconds is provided.<br>9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Awww.meanwell.com)<br>10. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).||||| 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Load regulation is measured from 0% to 100% rated load. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 8. Derating may be needed under low input voltages. Please check the derating curve for more details. ℃ /1000m with fanless models and of 5 ℃ /1000m _File Name:ENP-360-SPEC 2018-05-07_ **- ENP 360 series** 360W Level Ⅵ Desktop Type Power Supply ## **Block Diagram** **==> picture [475 x 343] intentionally omitted <==** **----- Start of picture text -----**<br> EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & &<br>CIRCUIT SWITCHING -V<br>RECTIFIERS FILTER<br>CONSTANT<br>CURRENT<br>O.L.P.<br>LIMITING &<br>FG DETECTION<br>PWM CIRCUIT<br>PFC CONTROL<br>CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 100 115 120 140 160 180 190 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:ENP-360-SPEC 2018-05-07_ 360W Level Ⅵ Desktop Type Power Supply ## **- ENP 360 series** **==> picture [103 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>**----- End of picture text -----**<br> **==> picture [460 x 452] intentionally omitted <==** **----- Start of picture text -----**<br> Case No. 252 Unit:mm<br>192 45.5 4.3<br>LED<br>TB1<br>1 47.5<br>2<br>3<br>4<br>2- M3 L=5<br>VR<br>SWITCH<br>INLET<br>Terminal Pin No. Assignment (TB1):<br>Pin No. Assignment<br>1,2 +V<br>3,4 -V<br>50<br>78 178<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:ENP-360-SPEC 2018-05-07_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →