- Manufacturer: MEAN WELL
- Product type:
- Battery Charger Type:Desktop; Battery Technologies Supported:Lead Acid, Li-Ion; Supply Voltage:60V; Battery Size Code:-; Battery IEC Code:-; Battery NEDA Code:-; Product Range:ENC-360 Seri
- SVHC: No SVHC (25-Jun-2025)
- Plug Type: -
- Product Range: ENC-360 Series
- Charge Current: 6A
- Output Voltage: 36V to 60V
- Supply Voltage: 60V
- Battery Size Code: -
- Battery Charger Type: Desktop
- No. of Cells Charged: -
- Battery Technologies Supported: Lead Acid, Li-Ion
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 63.51 € |
| Current stock | 10+ |
| Lead time | 30 days |
**ENC - 360 series** 360W Programmable Desktop Type Battery Charger ## ■ ## ■ ## ■ ℃ **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:ENC-360-SPEC 2018-11-05_ **ENC - 360 series** 360W Programmable Desktop Type Battery Charger ## **SPECIFICATION** |**ENC-360-24**<br>**ENC-360-48**<br>**ENC-360-12**<br>**MODEL**<br>**BOOST CHARGE VOLTAGE(Vfloat)(default)**<br>**FLOAT CHARGE VOLTAGE(Vfloat)(default)**<br>**RATED POWER**<br>**RECOMMENDED BATTERY**<br>**CAPACITY (AMP HOURS) Note.4**<br>**LEAKAGE CURRENT FROM**<br>**BATTERY (Typ.)**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**REVERSE POLARITY**<br>**SAFETY STANDARDS**<br>**FUNCTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**TEMPERATURE COMPENSATION**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>14.4V<br>28.8V<br>57.6V<br>13.8V<br>27.6V<br>55.2V<br>345.6W<br>345.6W<br>345.6W<br>24A<br>12A<br>6A<br>85 ~ 250AH<br>45 ~ 125AH<br>25 ~ 65AH<br><1mA<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.95/230VAC at full load<br>93%<br>94%<br>91%<br>COLD START 80A at 230VAC<br><3.5mA / 240VAC<br>31 ~ 36.5V<br>62.1 ~ 72.9V<br>15.5 ~ 18.2V<br>Protection type : Shut down and latch off o/p voltage, re-power on to recover<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>By internal fuse<br>IEC60950-1, UL60950-1 EAC TP TC 004<br>approved<br>,<br>,BSMI CNS14336-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>By NTC<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>138.7K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>192*178*45.5mm (L*W*H)<br>1.5Kg; 10pcs/16Kg /1.38CUFT<br>3.8A/115VAC 1.9A/230VAC<br>**AC CURRENT (Typ.)**<br>**CHARGE VOLTAGE RANGE Note.3** 9 ~ 15V<br>18 ~ 30V<br>36 ~ 60V<br>**OUTPUT CURRENT(CC) (default)**<br>**SHORT CIRCUIT**<br>**Note.6**<br>**OVER VOLTAGE**<br>**Note.7**<br>Protection type : Shut down O/P voltage, re-power on to recover<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>3. This is the range when programming Vboost or Vfloat by using SBP-001, the smart battery charging programmer.<br>4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.<br>℃<br>℃<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024, BSMI CNS13438<br>**Standard**<br>**Standard**<br>**Test Level / Note**<br>**Test Level / Note**<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 2, 3V/m<br>Level 2, 1KV<br>Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth<br>Level 2, 3Vrms<br>Level 1, 1A/m<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>-----<br>-----<br>~~a~~<br>~~RO~~<br>ee<br>a<br>a<br>sn<br>a<br>a~~ee~~<br>a<br>a<br>a<br>I<br>~~a~~<br>PO<br>~~re~~<br>~~a~~<br>aee<br>a<br>~~ee~~<br>Es<br>a<br>a~~ee~~<br>~~ee~~<br>~~GO~~<br>~~Ge~~<br>~~eG~~<br>~~GO~~<br>~~GO~~<br>~~Pd~~<br>~~eG~~<br>~~GO~~<br>~~GC~~<br>~~es~~<br>~~eG~~<br>~~GO~~<br>~~GO~~<br>a<br>a<br>a<br>7. Each model incorporates<br>a MCU-controlled dynamic over voltage protection, which is about 115% of Vboost over Constant Current stage and Constant<br>Voltage stage whereas 115% of Vfloat over Float stage.<br>8. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**ENC-360-24**<br>**ENC-360-48**<br>**ENC-360-12**<br>**MODEL**<br>**BOOST CHARGE VOLTAGE(Vfloat)(default)**<br>**FLOAT CHARGE VOLTAGE(Vfloat)(default)**<br>**RATED POWER**<br>**RECOMMENDED BATTERY**<br>**CAPACITY (AMP HOURS) Note.4**<br>**LEAKAGE CURRENT FROM**<br>**BATTERY (Typ.)**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ENVIRONMENT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**REVERSE POLARITY**<br>**SAFETY STANDARDS**<br>**FUNCTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**WORKING TEMP.**<br>**TEMPERATURE COMPENSATION**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**PROTECTION**<br>14.4V<br>28.8V<br>57.6V<br>13.8V<br>27.6V<br>55.2V<br>345.6W<br>345.6W<br>345.6W<br>24A<br>12A<br>6A<br>85 ~ 250AH<br>45 ~ 125AH<br>25 ~ 65AH<br><1mA<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>PF>0.98/115VAC, PF>0.95/230VAC at full load<br>93%<br>94%<br>91%<br>COLD START 80A at 230VAC<br><3.5mA / 240VAC<br>31 ~ 36.5V<br>62.1 ~ 72.9V<br>15.5 ~ 18.2V<br>Protection type : Shut down and latch off o/p voltage, re-power on to recover<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>By internal fuse<br>IEC60950-1, UL60950-1 EAC TP TC 004<br>approved<br>,<br>,BSMI CNS14336-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>By NTC<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>138.7K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>192*178*45.5mm (L*W*H)<br>1.5Kg; 10pcs/16Kg /1.38CUFT<br>3.8A/115VAC 1.9A/230VAC<br>**AC CURRENT (Typ.)**<br>**CHARGE VOLTAGE RANGE Note.3** 9 ~ 15V<br>18 ~ 30V<br>36 ~ 60V<br>**OUTPUT CURRENT(CC) (default)**<br>**SHORT CIRCUIT**<br>**Note.6**<br>**OVER VOLTAGE**<br>**Note.7**<br>Protection type : Shut down O/P voltage, re-power on to recover<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>3. This is the range when programming Vboost or Vfloat by using SBP-001, the smart battery charging programmer.<br>4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.<br>℃<br>℃<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024, BSMI CNS13438<br>**Standard**<br>**Standard**<br>**Test Level / Note**<br>**Test Level / Note**<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>EN61000-3-2<br>EN61000-3-3<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 2, 3V/m<br>Level 2, 1KV<br>Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth<br>Level 2, 3Vrms<br>Level 1, 1A/m<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class B<br>-----<br>-----<br>~~a~~<br>~~RO~~<br>ee<br>a<br>a<br>sn<br>a<br>a~~ee~~<br>a<br>a<br>a<br>I<br>~~a~~<br>PO<br>~~re~~<br>~~a~~<br>aee<br>a<br>~~ee~~<br>Es<br>a<br>a~~ee~~<br>~~ee~~<br>~~GO~~<br>~~Ge~~<br>~~eG~~<br>~~GO~~<br>~~GO~~<br>~~Pd~~<br>~~eG~~<br>~~GO~~<br>~~GC~~<br>~~es~~<br>~~eG~~<br>~~GO~~<br>~~GO~~<br>a<br>a<br>a<br>7. Each model incorporates<br>a MCU-controlled dynamic over voltage protection, which is about 115% of Vboost over Constant Current stage and Constant<br>Voltage stage whereas 115% of Vfloat over Float stage.<br>8. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|**ENC-360-12**|**ENC-360-24**|**ENC-360-48**| |---|---|---|---|---| ||**BOOST CHARGE VOLTAGE(Vfloat)(default)**<br>~~a~~|14.4V<br>~~a~~|28.8V<br>~~a~~|57.6V<br>~~a~~| ||**FLOAT CHARGE VOLTAGE(Vfloat)(default)**<br>~~a~~<br>~~RO~~<br>ee|13.8V<br>~~a~~<br>~~RO~~|27.6V<br>~~a~~<br>~~RO~~|55.2V<br>~~a~~<br>~~RO~~| ||**CHARGE VOLTAGE RANGE Note.3** <br>~~RO~~<br>ee|9 ~ 15V<br>~~RO~~|18 ~ 30V<br>~~RO~~|36 ~ 60V<br>~~RO~~| ||**OUTPUT CURRENT(CC) (default)**<br>ee<br>a|24A|12A|6A| ||**RATED POWER**<br>a<br>a|345.6W|345.6W|345.6W| ||**RECOMMENDED BATTERY**<br>**CAPACITY (AMP HOURS) Note.4**<br>a|85 ~ 250AH|45 ~ 125AH|25 ~ 65AH| ||**LEAKAGE CURRENT FROM**<br>**BATTERY (Typ.)**|<1mA||| ||**VOLTAGE RANGE**<br>**Note.5**<br>sn<br>a|90 ~ 264VAC 127 ~ 370VDC<br>sn||| ||**FREQUENCY RANGE**<br>a<br>a|47 ~ 63Hz<br>||| ||**POWER FACTOR (Typ.)**<br>a<br>a|PF>0.98/115VAC, PF>0.95/230VAC at full load<br>||| ||**EFFICIENCY (Typ.)**<br>a~~ee~~|91%<br>~~ee~~|93%<br>~~ee~~|94%<br>~~ee~~| ||**AC CURRENT (Typ.)**<br>a<br>a|3.8A/115VAC 1.9A/230VAC||| ||**INRUSH CURRENT (Typ.)**<br>a<br>a|COLD START 80A at 230VAC||| ||**LEAKAGE CURRENT**<br>a<br>a<br>I|<3.5mA / 240VAC<br>~~a~~||| ||**SHORT CIRCUIT**<br>**Note.6**<br>a<br>I|Protection type : Shut down O/P voltage, re-power on to recover<br>~~a~~||| ||**OVER VOLTAGE**<br>**Note.7**<br>I<br>PO<br>~~re~~|31 ~ 36.5V<br>62.1 ~ 72.9V<br>15.5 ~ 18.2V<br>Protection type : Shut down and latch off o/p voltage, re-power on to recover<br>~~a~~<br>PO||| ||**REVERSE POLARITY**<br>PO<br>~~re~~<br>~~a~~<br>|By internal fuse<br>PO||| ||**OVER TEMPERATURE**<br>PO<br>~~re~~<br>~~a~~<br>|Shut down O/P voltage, recovers automatically after temperature goes down<br>PO||| ||**TEMPERATURE COMPENSATION**<br>~~a~~<br>ee|By NTC||| ||**WORKING TEMP.**<br>ee<br>a|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃||| ||**WORKING HUMIDITY**<br>ee<br>a<br>~~ee~~|20 ~ 95% RH non-condensing<br>~~ee~~||| ||**STORAGE TEMP., HUMIDITY**<br>~~ee~~<br>Es|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>~~ee~~||| ||**TEMP. COEFFICIENT**<br>Es|±<br>℃<br>℃<br>0.05%/<br>(0 ~ 50<br>)||| ||**VIBRATION**<br>Es<br>a<br>a|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>||| ||**SAFETY STANDARDS**<br>a|IEC60950-1, UL60950-1 EAC TP TC 004<br>approved<br>,<br>,BSMI CNS14336-1<br>||| ||**WITHSTAND VOLTAGE**<br>a~~ee~~|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>~~ee~~||| ||**ISOLATION RESISTANCE**<br>~~ee~~|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~ee~~||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>a<br>a|**Parameter**<br>~~GO~~|**Standard**<br>~~GO~~|**Test Level / Note**<br>~~GO~~| |||Conducted<br>~~Ge~~|EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>~~Ge~~|Class B<br>~~Ge~~| |||Radiated<br>~~eG~~|EN55032 (CISPR32) / FCC PART15 (CISPR22)<br>~~eG~~|Class B<br>~~eG~~| |||Harmonic Current<br>~~GO~~|EN61000-3-2<br>~~GO~~|-----<br>~~GO~~| |||Voltage Flicker<br>~~GO~~|EN61000-3-3<br>~~GO~~|-----<br>~~GO~~| |||EN55024, BSMI CNS13438<br>~~Pd~~||| |||**Parameter**<br>~~eG~~|**Standard**<br>~~eG~~|**Test Level / Note**<br>~~eG~~| |||ESD<br>~~GO~~|EN61000-4-2<br>~~GO~~|Level 3, 8KV air ; Level 2, 4KV contact<br>~~GO~~| |||Radiated<br>~~GC~~|EN61000-4-3<br>~~GC~~|Level 2, 3V/m<br>~~GC~~| |||EFT / Burst<br>~~es~~|EN61000-4-4<br>~~es~~|Level 2, 1KV<br>~~es~~| |||Surge<br>~~eG~~|EN61000-4-5<br>~~eG~~|Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth<br>~~eG~~| |||Conducted<br>~~GO~~|EN61000-4-6<br>~~GO~~|Level 2, 3Vrms<br>~~GO~~| |||Magnetic Field<br>~~GO~~|EN61000-4-8<br>~~GO~~|Level 1, 1A/m<br>~~GO~~| |||Voltage Dips and Interruptions|EN61000-4-11|>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| |||138.7K hrs min. MIL-HDBK-217F (25<br>)<br>℃||| ||**DIMENSION**<br>a<br>a<br>a|192*178*45.5mm (L*W*H)||| ||**PACKING**<br>1.5Kg; 10pcs/16Kg /1.38CUFT<br>1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.<br>2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>3. This is the range when programming Vboost or Vfloat by using SBP-001, the smart battery charging programmer.<br>4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.<br>℃<br>℃<br>a<br>7. Each model incorporates<br>a MCU-controlled dynamic over voltage protection, which is about 115% of Vboost over Constant Current stage and Constant<br>Voltage stage whereas 115% of Vfloat over Float stage.<br>8. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on http:/Wwww.meanwell.com)<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).|||| 3. This is the range when programming Vboost or Vfloat by using SBP-001, the smart battery charging programmer. 4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on. ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating altitude higher than 2000m(6500ft). _File Name:ENC-360-SPEC 2018-11-05_ **ENC - 360 series** 360W Programmable Desktop Type Battery Charger ## **Block Diagram** **==> picture [498 x 350] intentionally omitted <==** **----- Start of picture text -----**<br> POLARITY<br>EMI FILTER PFC POWER RECTIFIERS PROTECTIONREVERSE +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.C.P.<br>O.L.P.<br>DETECTION<br>FG<br>PWM CIRCUIT<br>PFC CONTROL<br>CONTROL<br>O.V.P.<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>80<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-30 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 100 115 120 140 160 180 190 200 220 240 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:ENC-360-SPEC 2018-11-05_ **ENC - 360 series** ## 360W Programmable Desktop Type Battery Charger ## **Function Manual** ## **1.Charging Curve** - ※ This series provides a 3 stage charging. The default curve is programmable, whereas other pre-defined curves can be activated by the means of the DIP switch; please refer to the table below and the Mechanical Specification. - ※ To accommodate the parameters of the charging curve, SBP-001, the smart battery charging programmer designed by MEAN WELL, and a personal computer are needed. Please contact MEAN WELL for details. - ◎ Default 3 stage charging curve **==> picture [267 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Start<br>Vboost<br>Vfloat<br>Charge Voltage<br>100% CC<br>10% CC<br>Charge Current Constant Current Constant Voltage Float<br>stage 1 stage 2 stage 3<br>Color of LED Orange Green<br>Status Indicator<br>**----- End of picture text -----**<br> - Suitable for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese). - Embedded 3 stage charging curve **==> picture [280 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> MODEL Description CC(default) Vboost Vfloat<br>Default, programmable 14.4 13.8<br>Pre-defined, gel batter 14 13.6<br>12V 24A<br>Pre-defined, flooded battery 14.2 13.4<br>Pre-defined, AGM battery 14.5 13.5<br>Default, programmable 28.8 27.6<br>Pre-defined, gel battery 28 27.2<br>24V 12A<br>Pre-defined, flooded battery 28.4 26.8<br>Pre-defined, AGM battery 29 27<br>Default, programmable 57.6 55.2<br>Pre-defined, gel battery 56 54.4<br>48V 6A<br>Pre-defined, flooded battery 56.8 53.6<br>Pre-defined, AGM battery 58 54<br>**----- End of picture text -----**<br> ## **2. Front Panel LED Indicators & Corresponding Signal at Function Pins** |LED|Description| |---|---| |Green|Float (stage 3)| |Orange|Charging (stage 1 or stage 2)| _File Name:ENC-360-SPEC 2018-11-05_ **ENC - 360 series** ## 360W Programmable Desktop Type Battery Charger ## **Mechanical Specification** **==> picture [493 x 325] intentionally omitted <==** **----- Start of picture text -----**<br> Case No. 252 Unit:mm<br>192 45.5 4.3<br>LED<br>TB1<br>1 47.5<br>2<br>3<br>4<br>DIP<br>CN31 SW 2- M3 L=5<br>CN31 1 2<br>1 5<br>2 6<br>SWITCH<br>INLET<br>50<br>78 178<br>**----- End of picture text -----**<br> |DIP SW:<br>1<br>2<br>OFF<br>OFF<br>ON<br>OFF<br>OFF<br>ON<br>ON<br>ON<br>Description<br>Default, programmable<br>Pre-defined, Gel battery<br>Pre-defined, flooded battery<br>Pre-defined, AGM battery<br>Terminal Pin No. Assignment (TB1):<br>Pin No.<br>1,2<br>3,4<br>Assignment<br>+V<br>-V|DIP SW:<br>1<br>2<br>OFF<br>OFF<br>ON<br>OFF<br>OFF<br>ON<br>ON<br>ON<br>Description<br>Default, programmable<br>Pre-defined, Gel battery<br>Pre-defined, flooded battery<br>Pre-defined, AGM battery<br>Terminal Pin No. Assignment (TB1):<br>Pin No.<br>1,2<br>3,4<br>Assignment<br>+V<br>-V|DIP SW:<br>1<br>2<br>OFF<br>OFF<br>ON<br>OFF<br>OFF<br>ON<br>ON<br>ON<br>Description<br>Default, programmable<br>Pre-defined, Gel battery<br>Pre-defined, flooded battery<br>Pre-defined, AGM battery<br>Terminal Pin No. Assignment (TB1):<br>Pin No.<br>1,2<br>3,4<br>Assignment<br>+V<br>-V|Connector Pin No. Assignment (CN31) :<br>HRS DF11-6DP-2DS or equivalent|Connector Pin No. Assignment (CN31) :<br>HRS DF11-6DP-2DS or equivalent|Connector Pin No. Assignment (CN31) :<br>HRS DF11-6DP-2DS or equivalent|Connector Pin No. Assignment (CN31) :<br>HRS DF11-6DP-2DS or equivalent| |---|---|---|---|---|---|---| ||||Pin No.|Assignment|Mating Housing|Terminal| ||||1|Prog- +3.3V|or equivalent<br>HRS DF11-6DS|or equivalent<br>HRS DF11-**SC| ||||2|Prog- GND||| ||||3|Prog- RX||| ||||4|Prog- TX||| |1|2|Description|5|RTH+||| |OFF|OFF|Default, programmable|6|RTH-||| |ON|OFF|Pre-defined, Gel battery||||| |OFF|ON|Pre-defined, flooded battery||||| |ON|ON|Pre-defined, AGM battery||||| _File Name:ENC-360-SPEC 2018-11-05_
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →