EME05US36
AC/DC PCB Mount Power Supply (PSU), Medical, 1 Output, 5 W, 36 VDC, 138 mA
- Manufacturer: XP POWER
- Product type: AC / DC PCB Mount Power Supplies
- No. of Outputs:1 Output; Output Power Max:5W; Output Voltage - Output 1:36V; Output Current - Output 1:138mA; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (15-Jan-2018)
- Depth: 38.1mm
- Width: 25.4mm
- Height: 15.2mm
- Product Range: EME05 Series
- No. of Outputs: 1 Output
- Output Power Max: 5W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 138mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 15.22 € |
| Current stock | 10+ |
| Lead time | 30 days |
EME05 series ## **Convection** 5W **cooled** ## **AC-DC power supplies** The EME05 is a series of open frame and encapsulated 5W AC-DC single output power supplies designed for medical (2 x MOPP) applications. The series provides two mechanical options, open frame (suffix -P) and encapsulated PCB mount. With approvals to world-wide medical safety standards, compliance with class B for both conducted and radiated emissions and a 130%, 30s peak load capability, these class II isolation parts benefit system designers with easy integration into the latest medical products and applications. ## **Features** ## **Applications** ## **Dimensions** - f Regulated single outputs 3.3V to 48VDC - f Input range 85 to 264VAC - f Encapsulated or open frame PCB mount package - f Medical approvals (2 x MOPP) **==> picture [135 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> Healthcare Home Medical<br>healthcare diagnostic<br>**----- End of picture text -----**<br> EME05: 36.1 x 25.4 x 15.2mm (1.50” x 1.00” x 0.60”) EME05-P 35.6 x 23.7 x 17.6mm (1.40” x 0.94” x 0.69” ) ## **Documentation** - f Class II - f Peak load capability For further information click the link or scan the code - f No external components required - f 3 year warranty xppower.com ## **Models & ratings** |Model number(2)|Output voltage|Output current|Output current|Output power| |---|---|---|---|---| |||Nominal|Peak(1)|| |EME05US03|3.3VDC|1510mA|1960mA|5W| |EME05US05|5.0VDC|1000mA|1300mA|5W| |EME05US09|9.0VDC|555mA|722mA|5W| |EME05US12|12.0VDC|416mA|541mA|5W| |EME05US15|15.0VDC|333mA|433mA|5W| |EME05US24|24.0VDC|208mA|270mA|5W| |EME05US36|36.0VDC|138mA|180mA|5W| |EME05US48|48.0VDC|104mA|135mA|5W| ## Notes: 1. Peak load lasting <30s with a maximum duty cycle of 10%, average output power not to exceed nominal. 2. For Open Frame version add suffix -P to model number, e.g. EME05US12-P. 1 | **AC-DC power supplies** ## EME05 series ## **Input** **==> picture [553 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Input voltage range|85||264|VAC|| |Input frequency|47||63|Hz|| |Input current - full load||0.10/0.06||A rms|At 115/230VAC| |No load input power|||0.3|W|| |Inrush current|||40|A|At 230VAC| |Earth leakage current|Class II construction no earth||||| |Input protection|Internal T1.0 A/250VAC fuse ftted in line and neutral||||| ## **Output** **==> picture [553 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Output voltage|3.3||48|VDC|| |Initial set accuracy|||±1|%|| |Minimum load|No minimum load required||||| |Line regulation|||±0.5|%|| |Load regulation|||±1|%|3% for 03 & 05 models, 2% for others from 10% to 100% load| |Start up delay|||2|s|| |Start up rise time|||14|ms|| |Hold up time|12|||ms|At full load and 115VAC| |Transient response|||4|%|Deviation, recovery within 1% in less than 500μs for a 25% load change| |Ripple & noise|||50|mV pk-pk|3.3 - 5V versions, 20MHz bandwidth| ||||90||9V versions, 20MHz bandwidth| ||||120||12 - 15V versions, 20MHz bandwidth| ||||200||24 - 48V versions, 20MHz bandwidth| |Overvoltage protection|115||140|% Vnom|Recycle input to reset| |Overload protection|130||200|%|| |Short circuit protection|Trip & restart (hiccup mode)||||| |Temperature coeffcient|||0.05|%/˚C|| ## **General** |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Effciency||80||%|| |Isolation: input to output|4000|||VAC|2 x MOPP| |Switching frequency||130||kHz|| |Power density|||0.33 (5.5)|W/cm3(W/in3)|| |Mean time between failure||>400||khrs|MIL-HDBK-217F, +25°C GB.| |Weight||14 (0.03)||g (lb)|Open frame versions (-P)| |||24 (0.053)|||Encapsulated version| Specifications subject to change without notice. 2 **AC-DC power supplies** ## EME05 series ## **Environmental** **==> picture [553 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Operating temperature|-25||+70|°C|Derate linearly from 100% at +50°C to 50% at +70°C| |Storage temperature|-40||+85|°C|| |Cooling|Convection-cooled||||| |Humidity|||95|%RH|Non-condensing| |Operating altitude|||3048|m|| |Shock|IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes||||| |Vibration|IEC68-2-6, 2 g, 10Hz to 500kHz, 10 mins/cycle, 60 mins each cycle||||| ## **Efficiency graphs** ## EME05US12 **==> picture [47 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> EME05US24<br>**----- End of picture text -----**<br> **==> picture [257 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>115VAC input<br>230VAC input<br>60<br>50<br>40<br>10 20 30 40 50 60 70 80 90 100<br>Load (%)<br>Efficiency (%)<br>**----- End of picture text -----**<br> **==> picture [252 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>115VAC input<br>230VAC input<br>60<br>50<br>40<br>10 20 30 40 50 60 70 80 90 100<br>Load (%)<br>Efficiency<br>**----- End of picture text -----**<br> ## **EMC: emissions** **==> picture [554 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Notes & conditons| |---|---|---|---| ||||| |Conducted|EN55011|Class B|| |Radiated|EN55011|Class B|| |Harmonic currents|EN61000-3-2|Class A|| |Voltage ficker|EN61000-3-3||| 3 **AC-DC power supplies** ## EME05 series ## **EMC: immunity** **==> picture [553 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Criteria|Notes & conditons| |---|---|---|---|---| |||||| |Medical device EMC|IEC60601-1-2|Ed.4.0 : 2014|A|| |ESD immunity|EN61000-4-2|±6kV contact,<br>±15kV air discharge|A|| |Radiated immunity|EN61000-4-3|10V/m|A|80% mod, 80MHz - 2.7GHz plus discrete communcation<br>proximity feld frequencies| |EFT|EN61000-4-4|3|A|| |Surge|EN61000-4-5|2|A|| |Conducted|EN61000-4-6|10Vrms|A|| |Magnetic feld|EN61000-4-8|30A/m|A|| |Dips and interruptions|EN60601-1-2<br>(100 VAC)|70% UT (70 VAC) for 500ms|A|| |||40% UT (40 VAC) for 100ms|A|Load de-rated to 50%| |||<5% UT (0 VAC) for 10ms|A|| |||<5% UT (0 VAC) for 5000ms|B|| ||EN60601-1-2<br>(240 VAC)|70% UT (168 VAC) for 500ms|A|| |||40% UT (96 VAC) for 100ms|A|| |||<5% UT (0 VAC) for 10ms|A|| |||<5% UT (0 VAC) for 5000ms|B|| ## **Safety approvals** **==> picture [554 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> Certification Standard Notes & conditions<br>CB IEC60601-1<br>UL ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08 Medical<br>TUV EN60601-1<br>CE Meets all applicable directives<br>UKCA Meets all applicable legislation<br>Means of protection Category<br>Primary to secondary 2 x MOPP (Means of Patient Protection) IEC60601-1 Ed.3<br>**----- End of picture text -----**<br> 4 **AC-DC power supplies** ## EME05 series ## **Mechanical details** **==> picture [264 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Encapsulated BOTTOM VIEW<br>**----- End of picture text -----**<br> **==> picture [543 x 546] intentionally omitted <==** **----- Start of picture text -----**<br> 25.4 (1.0)<br>5.1<br>19.05 (0.75)<br>2.53 (0.10) (0.20) 15.2 (0.60)<br>2 1<br>38.1<br>4 Ø1.02<br>(1.50)<br>(Ø0.04)<br>33.02<br>(1.30)<br>2.54<br>(0.10)<br>3 4<br>2.53 (0.10) 12.7 (0.5)<br>Pin connections<br>Pin Single<br>Open frame (-P) 12.7 1 ACN<br>35.6 (1.40)<br>(0.50) 2 ACL<br>2 3 3 -Vout<br>4 +Vout<br>23.7<br>4 (0.94)<br>1<br>9.40<br>1.28 (0.05)<br>33.02 (1.30) (0.37)<br>13.0<br>(0.51) max<br>4.4<br>(0.17)<br>3.8 17.6<br>(0.15) (0.69)<br>Ø1.0 (Ø0.039)<br>Ø1.80 (Ø0.071)<br>3.05 (0.120)<br>19.5 (0.750)<br>2.0 (0.08) max.<br>**----- End of picture text -----**<br> Notes: 1. Dimensions in mm (inches). 2. Weight: Open frame versions (-P): 14g (0.03lbs) Encapsulated: 24g (0.053lbs) 3. Tolerances: x.x = ± 0.5 (x.xx = ± 0.02) x.xx = ± 0.25 (x.xxx = ± 0.01) 29 April 2026 5
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →