EMC 1500
Panel Mount Timer, Elapsed, Single Hole Mounting, 5 VDC, 27 VDC, 0 s, 99999 h, 5.5 mm Dia
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type: Hour Meters
- Supply Voltage Min:5VDC; Supply Voltage Max:27VDC; Time Min:0s; Time Max:99999h; Panel Cutout Height:21mm; Panel Cutout Width:44mm; Product Range:-; SVHC:No SVHC (15-Jan-2019); Character
- SVHC: No SVHC (07-Nov-2024)
- Time Max: 99999h
- Time Min: 9999.9h
- Product Range: -
- Panel Cutout Width: -
- Supply Voltage Max: 27VDC
- Supply Voltage Min: 5VDC
- Panel Cutout Height: -
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 42.32 € |
| Current stock | 10+ |
| Lead time | 30 days |
Single Hole Mounting Elapsed Hour Meter ## **EMC 1500** ## _eee-— No: 716 - Page 1 of 2 EMC 1500 is an easy to mount LCD digital elapsed hour meter. The module features 9999.9 and 99999 hour ranges, resulting in 1/10 hour and 1 hour resolution respectively. A leading zero blanking input is provided allowing the user to switch off unwanted leading zeros. The module incorporates an output that pulses high after every hour counted. This is particularly useful in applications where maintenance or inspection is required at regular time intervals. The timer features Trip and Total ranges. The Trip range can be reset to zero. The meter's readings are stored in the module's internal memory and are retained even when the unit is not powered. To mount the module, drill a single 5.5mm / / " hole, locate its screw threaded stud through the hole and secure with the washer and nut provided. The module's 8 connection wires pass through the hollow stud into the target application. A rubber seal is included, providing splashproof protection for the unit when fitted to the meter during installation. - **Single Hole Mounting** - **9999.9 and 99999 Hour Ranges** - **9mm / 0.35" LCD Digit Height** - **Reset and Trip/Total Inputs** **==> picture [82 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> TRIP TOTAL Hrs<br>LOLOLe bene<br>4055.4<br>- - - - - - - - - -<br>**----- End of picture text -----**<br> - **Leading Zero Blanking Input** - **Pulse Output Every Hour** Shown Actual Size - **Splashproof** **Stock Number Easy Mounting Elapsed Hour Meter EMC 1500** Seal es **Specification Min.** ~~es~~ **T** ~~ee~~ **yp. Max. Unit** Panel 8 Wires - 30cm (12.0) Resolution ~~SS~~ Range 9999.9 0.1 Hour ~~PF~~ Range 99999 1 Hour Elapsed ~~eS~~ Accuracy* ±2 ±6 Sec./24Hrs. Hour Meter ~~SS ES~~ Operating temperature range 0 50 °C yn ~~ES~~ _ / ~~eS~~ Supply voltage (V+) 5 27 V d.c. \ Supply current ~~SS ES~~ 1.5 mA ~~= [[es]~~ InInput High Voltageput Low Voltage ((VVILIH))***** 20 ~~es es~~ V+0.5 ~~es ee~~ VV Nut * Based upon constant running. There is potential for ±2 seconds error each time 9.0 Washer (0.35) the module is powered down and then up again. Over time, the accumulated error - Based upon constant running. There is potential for ±2 seconds error each time the module is powered down and then up again. Over time, the accumulated error approximates to zero. - ** Applies to the inputs: Range, V-Sense, LZB, Reset and Trip/Total *** Applies to V-Sense input only. ## **SAFETY** To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s wires must not exceed 60Vd.c. The user must ensure that the incorporation of the meter into equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for ElectricalEquipmentforMeasuring,ControlandLaboratoryUse). **DIMENSIONS All dimensions in mm (inches)** LCD shown in power-on self-test mode. **CONNECTION** TRIP ~~©~~ TOTAL Hrs 0 Black 0V 1 Brown 9999.9/99999 2 Red V+ Lee he Lane 3 Orange Voltage Sense - - - - - - - - - - 4 Yellow 1 Hr Pulse ~~|~~ Tere ree 5 Green Leading Zero Blanking 6 Blue Reset ~~>|~~ 44.0 (1.73) 7 Violet Trip/Total 10.5 REAR VIEW (0.41) **FITTING THE Hour Meter** 5.00 Drill a 5.5mm / / " hole in the panel. Fit seal to the rear of the module. Fit the module to (0.20) 10.5 the panel by passing its screw threaded stud and the wires through the hole, fitting the (0.41) washer and spring washer and tightening the nut provided. Take care not to trap any of theconnectingwires. Do notovertightenthenutasthismaydamagethemeter. DO NOT PULL THE WIRES AND DO NOT ALLOW SCREW TERMINALS OR OTHER 22.0 (0.87) 22.0 (0.87) WIRES TO HANG FROM THE MODULE'S WIRES, AS THIS MAY DAMAGE THE Module thickness: 5.5mm (0.22") DO NOT PULL THE WIRES AND DO NOT ALLOW SCREW TERMINALS OR OTHER WIRES TO HANG FROM THE MODULE'S WIRES, AS THIS MAY DAMAGE THE PRODUCT. **WEBSITE: http://www.lascarelectronics.com/** **LASCAR ELECTRONICS (HK) LTD. 8th FLOOR, CHINA AEROSPACE CENTRE, 143 HOI BUN ROAD, KWUN TONG, KOWLOON, HONG KONG TEL: +852 2389 6502 FAX: +852 2389 6535 E-mail: saleshk@lascar.com.hk** **LASCAR ELECTRONICS LTD. MODULE HOUSE, WHITEPARISH, WILTSHIRE SP5 2SJ UK** **LASCAR ELECTRONICS INC. 4258 West 12th Street, Erie, PA 16505 USA** **E-mail: sales@lascar.co.uk E-mail: us-sales@lascarelectronics.com** **TEL: +44 (0)1794 884567 FAX: +44 (0)1794 884616 TEL: +1 (814) 835 0621 FAX: +1 (814) 838 8141** ## **WIRE FUNCTIONS** 0. Black 0V Negativepowersupplyconnection. 1. Brown RANGE Donotconnectfor99999Hourrange. Connectto0Vfor9999.9Hourrange. 2. Red V+ Positivepowersupplyconnection. 3. Orange V-SENSE ConnecttoV+tostart/continuecountingelapsedhours. Connectto0VordonotconnecttoreadTRIPorTOTALvaluewithoutcountingelapsedhours. 4. Yellow PULSE Normallyat0V,thisoutputgoesHigh(+3.3V)everyhourintheselectedmode. 5. Green LZB Donotconnecttodisplayleadingzeros. Connectto0Vtoblankallleadingzeros. Whenreadingis0000.0or00000,leadingzerosarenotblanked. 6. Blue RESET Connectmomentarily to 0Vtoresetthedisplaytozero(internallyconnectedtoV+viapull-upresistor). 7. Violet TRIP/TOTAL DonotconnectforTOTALmodeoperation.InTOTALmode,theelapsedhourmetercannotberesettozero. Connectto0VforTRIPmodeoperation.InTRIPmode,theelapsedhourmetercanberesettozero. **Warning : Do not connect the following wires to V+: RANGE, PULSE, LZB, RESET, TRIP/TOTAL, as this may damage the meter. The user must incorporate suitable protection circuitry in applications where the voltage to any of the meter's wires can exceed 27V d.c., including transient conditions, else damage to the meter may occur. In particular, for applications in harsh electrical environments, e.g. automotive, suitable external protection must be provided to protect against "load dump" conditions, transients, etc.** ## **DISPLAY FUNCTIONS** 8888.8 The 5 digit readout displays elapsed time in hours. TRIP Thissymbolisdisplayedwhentripmodeisselected(seeWireFunctionsabove) TOTAL Thissymbolisdisplayedwhentotalmodeisselected(seeWireFunctionsabove) ---------The10-segmentincrementingbarindicatesthatthemoduleisworkingcorrectlyandcountinghours. ## **APPLICATIONS** **==> picture [478 x 372] intentionally omitted <==** **----- Start of picture text -----**<br> V+ V+<br>S1<br>Red Orange Orange Red<br>Li i<br>© TOTAL Hrs © TOTAL Hrs<br>mr ac fa BD<br>MALS fol af al 2 2!<br>- -<br>Black Black Green Violet<br>S1<br>L 0V tt} 0V<br>Basic 3-wire operation: Leading zeros blanked.<br>- 99999 Hour range Close S1 to select TRIP mode.<br>- Leading Zeros are displayed<br>- Timing in TOTAL mode<br>Open S1 to read TOTAL value<br>without counting hours.<br>V+ V+<br>Orange Red Orange Red LED<br>TRIP © Hrs TRIP © Hrs R<br>Yellow<br>be 028 ol af be 08 of al<br>- -<br>Black Brown Violet Black Brown Violet<br>mic o3 0V m ac O23 : 0V<br>9999.9 Hour range Using the PULSE O/P to drive an LED.<br>- Leading Zeros are displayed The LED will illuminate once after every hour.<br>- Timing in TRIP mode<br>**----- End of picture text -----**<br> _**Specifications liable to change without prior warning**_ **EMC 1500 Issue 12 06/2010** **S.L. Applies to EMC 1500/3** **IRCN 0539**
Updated at April 24, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →