Image not available
Illustrative purposes only
EM2696AV53HO3S1XX
DIGITAL PANEL INSTRUMENTATION
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type: Digital Panel Meters
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 809.17 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **EM26 96Energy Management Energy Analyzer Type EM26 96** - **Class 1 (kWh) according to EN62053-21** - **Class B (kWh) according to EN50470-3** - **Class 2 (kvarh) according to EN62053-23** - **Accuracy ±0.5% RDG (current/voltage)** - **Dual colour backlight: no backlight, blue or white (selectable)** - **Energy analyzer** - **Instantaneous variables readout: 4 DGT** - **Energies/gas/water readout: 8 DGT** - **System variables: VLL, VLN, Admd, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd max, var, PF, Hz, Phase-sequence.** - **Single phase variables: VLL, VLN, A, VA, W, var, PF** - **Energy measurements: total and partial kWh and kvarh or based on 4 different tariffs; single phase measurements** - **Gas, cold water, hot water, kWh remote heating measurements** - **Hour counter (6+2 DGT)** - **Harmonic analysis (FFT) up to 15th harmonic (current/voltage)** - **TRMS measurements of distorted sine waves (voltages/currents)** - **M-bus communication by means of VMU-B adapter** - **Application adaptable display and programming procedure (Easyprog function)** - **Easy connections management** - **Certified according to MID Directive (option PF only): see “how to order” below** - **Other versions available (not certified, option XX):** - **see “how to order” on the next page** - **Universal power supply: 90 to 260AC/VDC** - **3 digital inputs for tariff selection, DMD synch or gas/water (hotcold) and remote heating metering (on request)** - **3 digital outputs for pulses or for alarms or as a mix of them (on request)** - **Front dimensions: 96x96mm** - **Protection degree (front): IP50** - **RS485 serial output (on request) (MODBUS-RTU), iFIX SCADA compatibility** ## **Product Descri tion p** Three-phase energy analyzer and for cost allocation. Houswith built-in configuration joying for panel mounting with stick and LCD data displaying; IP50 (front) protection degree. particularly indicated for active External Current and potential and reactive energy metering transformers connection. More- Certified according to MID Directive, Module B and Module D of Annex II, for legal metrology **MID** relevant to active electrical energy meters (see Annex V, MI003, of MID). Can be used for fiscal (legal) metrology. Only the total positive energy meter is certified according to MID. over the meter can be provided outputs, or for remote control. with digital outputs that can be RS485 communication port and used: for pulses proportional to 3 digital inputs are available as the active and reactive energy an option. being measured or for alarm ## **How to order EM26 96 AV5 3 H O3 S1 PF A** **Model Range code System Power supply Inputs/Outputs Communications Option Measurement** ## **T e Selection yp** ## **Communication** ## **System** ## **Range codes** **AV5:** 230 VLN/400VLL **3:** 3-phase, 4-wire; 1/5(10)A VLN : 160 V to 480 VLN VLL : 277 V to 830 VLL **Power supply AV6:** 120 VLN/208VLL 1/5(10)A VLN : 40 V to 144 VLN **H:** VLL : 70 V to 250 VLL - **XX:** none **S1:** RS485 port **Input/Output O1:** single open collector type (pulse or alarm) - **O3:** 3 open collector type (mixed combination of pulse, alarm and/or remote output) - **R2:** dual relay type (functions as per “O3”) **H:** 90 to 260VAC/DC (48 to 62Hz) - **I3:** 3 digital inputs for tariff selection or Gas/water/ energy/remote heating metering **==> picture [263 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> AV5 3 H O1 XX<br>po fo of ft | |<br>AV6 O3 S1<br>A<br>R2 PF<br>B<br>inthe I3 iF mH S1 i: al<br>Range System Power supplyInput/OutputCommunicationOption Measurement<br>**----- End of picture text -----**<br> **NOTE: please check the availability of the needed code on the verification path diagram on left before order.** ## **Options** **PF:** Certified according to MID Directive. Can be used for fiscal (legal) metrology. **1** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** **==> picture [72 x 72] intentionally omitted <==** ## **STANDARD** Not certified according to MID directive. Cannot be used for fiscal (legal) metrology. ## **How to order EM26 96 AV5 3 H O3 S1 XX** **Model Range code System Power supply Input/Output Communication Options** ## **T e Selection yp** ## **System** ## **Range codes** **AV5:** 230 VLN/400VLL **3:** balanced and 1/5(10)A unbalanced load: VLN : 160 V to 480 VLN 3-phase, 4-wire; VLL : 277 V to 830 VLL 3-phase, 3-wire; **AV6:** 120 VLN/208VLL 2-phase, 3-wire; 1/5(10)A 1-phase, 2-wire VLN : 40 V to 144 VLN VLL : 70 V to 250 VLL ## **Power supply** **H:** 90 to 260VAC/DC (48 to 62Hz) **Communication XX:** none **S1:** RS485 port ## **Input/Output** **O1:** single open collector type (pulse or alarm) **O3:** 3 open collector type (mixed combination of pulse, alarm and/or remote output) **R2:** dual relay type (functions as per “O3”) **I3:** 3 digital inputs for tariff selection or Gas/water/ energy/remote heating metering ## **Options** **XX:** none **==> picture [209 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> AV5 3 H O1 XX XX<br>AV6 O3 S1<br>R2<br>I3<br>Range System Power supplyInput/OutputCommunicationOption<br>**----- End of picture text -----**<br> **NOTE: please check the availability of the needed code on the verification path tables on left before order.** **2** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **In ut s ecifications p p** **==> picture [72 x 72] intentionally omitted <==** |**Rated inputs**<br>System type: 3<br>Current type<br>Galvanic insulation by<br>means of built-in CT’s<br>Current range (by CT)<br>AV5 and AV6: 1/5(10)<br>A<br>Voltage by direct connection<br>or VT/PT<br>AV5: 230 VLN/400VLL;<br>AV6: 120 VLN/208VLL<br>**Accuracy**(Display + RS485)<br>Ib: see below, Un: see below<br>(@25°C ±5°C, R.H. ≤60%,<br>50±5Hz/60±5Hz)<br>AV5 model<br>In: 5A, Imax: 10A; Un: 160<br>to 480VLN (277 to 830VLL)<br>AV6 model<br>In: 5A, Imax: 10A; Un: 40 to<br>144VLN (70 to 250VLL)<br>Current<br>AV5, AV6 models<br>From 0.002In to 0.2In:<br>±(0.5% RDG +3DGT)<br>From 0.2In to Imax:<br>±(0.5% RDG +1DGT).<br>Phase-neutral voltage<br>In the range Un: ±(0,5%<br>RDG +1DGT)<br>Phase-phase voltage<br>In the range Un: ±(1% RDG<br>+1DGT)<br>Frequency<br>±0.1Hz (50±5Hz/60±5Hz)<br>Active and Apparent power<br>±(1%RDG +2DGT)<br>Power Factor<br>±[0.001+1%(1.000 - “PF<br>RDG”)]<br>Reactive power<br>±(2%RDG +2DGT)<br>Active Energy<br>Class 1 according to<br>EN62053-21; class B<br>according to EN50470-3.<br>Reactive Energy<br>Class 2 according to<br>EN62053-23<br>AV5, AV6 models<br>In: 5A, Imax: 10A;<br>0.1 In: 0.5A.<br>Start up current: 10mA<br>Harmonic distortion<br>THD up to 15th harmonic<br>±3% reading<br>**Energy additional errors**<br>Influence quantities<br>According to EN62053-21,<br>EN62053-23<br>**Temperature drift**<br> ≤200ppm/°C<br>**Sampling rate**<br>1600 samples/s @ 50Hz<br>1900 samples/s @ 60Hz<br>**Display refresh time**<br>750 msec<br>**Display**<br>3 lines (1 x 8 DGT;<br>2 x 4 DGT)<br>Type<br>LCD, h 9.5mm, dual colour<br>backlight (selectable)<br>Instantaneous variables read-out 4 DGT<br>Energies<br>Exported: Total<br>6+1DGT or 7DGT (with “-“<br>sign).<br>Imported: 6+2, 7+1 or<br>8DGT|Overload status<br>EEEE indication when the<br>value being measured is<br>exceeding the “Continuous<br>inputs overload” (maximum<br>measurement capacity)<br>Max. and Min. indication<br>Max. instantaneous<br>variables: 9999; energies:<br>99 999 999. Min. instanta-<br>neous variables: 0; ener-<br>gies 0.00<br>**LEDs**<br>Red LED (Energy<br>consumption), according to<br>EN50470-3, EN62052-11<br>0.001 kWh/kvarh by pulse<br>if CT ratio by VT ratio is≤7;<br>0.01 kWh/kvarh by pulse if<br>CT ratio by VT ratio is > 7.1<br>≤70.0;<br>0.1 kWh/kvarh pulse if CT<br>ratio by VT ratio is > 70.1<br>≤700.0;<br>1 kWh/kvarh by pulse if CT<br>ratio by VT ratio is > 700.1;<br>1000 imp./kWh/kvarh.<br>Max frequency: 16Hz<br>**Measurements**<br>See “List of the variables<br>that can be connected to:”<br>Method<br>TRMS measurements of<br>distorted wave forms.<br>Couplingtype<br>Bymeans of external CT’s<br>**Crest factor**<br>≤3(15A max.peak)<br>**Current Overloads**<br>Continuous<br>10A, @ 50Hz<br>For 500ms<br>200A,@ 50Hz<br>**Voltage Overloads**<br>Continuous<br>1.2 Un<br>For 500ms<br>2 Un<br>**Input impedance**<br>208VL-L (AV6)<br>>1MΩ<br>400VL-L (AV5)<br>>1MΩ<br>1/5(10)A(AV5-AV6)<br>< 0.3VA<br>**Frequency**<br>50±5Hz/60±5Hz<br>**Joystick**<br>For variable selection:<br>programming of the<br>instrument working<br>parameters and Wdmd<br>max reset| |---|---| **3** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **Out ut s ecifications p p** **==> picture [72 x 72] intentionally omitted <==** |**Output specifications**|| |---|---| |**Digital outputs**<br>Pulse type<br>Number of outputs<br>Up to 3, independent.<br>Programmable from 0.001<br>to 10.00 kWh/kvarh per<br>pulse.<br>Type<br>Outputs connectable to the<br>energy meters (Wh/varh)<br>Pulse duration<br>TONselectable (30 ms<br>or 100 ms) according to<br>EN62053-31<br>TOFF:≥120ms, according to<br>EN62052-31<br>Alarm type<br>Number of outputs<br>Up to 3, independent<br>Alarm modes<br>Up alarm, down alarm (see<br>the table “List of the<br>variables that can be<br>connected to”)<br>Set-point adjustment<br>From 0 to 100% of the<br>display scale<br>Hysteresis<br>From 0 to full scale<br>On-time delay<br>0 to 255s<br>Output status<br>Selectable: normally<br>de-energized or normally<br>energized<br>Min. response time<br>≤ 700ms, filters excluded.<br>Set-point on-time delay: “0 s”<br>Remote control<br>The digital ouputs status can<br>be managed by means of<br>serial communication RS485,<br>if programmed as remote.<br>**Note**<br>The 3 digital outputs can<br>also work as a triple pulse<br>output, triple alarm output,<br>or in anyother combination.<br>**Static output**<br> Physical outputs<br>Max. 3<br>Purpose<br>For pulse output, alarm<br>output or remote control.<br>Signal<br>VON1.2 VDC/ max. 100 mA<br>VOFF30 VDC max.<br>Insulation<br>By means of optocouplers,<br>4000 VRMS output to<br>measuring inputs,<br>4000 VRMS output to<br>power supply input.|**Relay output**<br> Physical outputs<br>Max. 2<br>Purpose<br>For alarm output, pulse<br>output or remote control.<br>Type<br>Relay, SPST type<br>AC 1-5A @ 250VAC<br>DC 12-5A @ 24VDC<br>AC 15-1.5A @ 250VAC<br>DC 13-1.5A @ 24VDC<br>Insulation<br>4000 VRMS outputs to<br>measuring input.<br>4000 VRMS outputs to<br>power supplyinput.| ||**RS485**<br>Type<br>Multidrop, bidirectional<br>(static and dynamic<br>variables)<br>Connections<br>2-wire<br>Max. distance 1000m<br>(without amplifier)<br>Termination directly on the<br>instrument<br>Addresses<br>247, selectable by means<br>of the front joystick<br>Protocol<br>MODBUS/JBUS (RTU)<br>Data (bidirectional)<br>Dynamic (reading only)<br>System and phase<br>variables: see table “List of<br>variables...”<br>Static (reading and writing) All the configuration<br>parameters.<br>Data format<br>1 start bit, 8 data bit, no<br>parity,1 stop bit<br>Baud-rate<br>4800, 9600 bits/s<br>Driver input capability<br>1/5 unit load<br>Maximum 160 transceivers<br>on the same bus, which<br>can be expanded with<br>signal amplifiers.<br>Insulation<br>By means of optocouplers,<br>4000 VRMS output to<br>measuring input.<br>4000 VRMS output to<br>power supply input| ## **Di ital in ut s ecifications g p p** Number of inputs Input frequency Prescaler adjustment Contact measuring voltage Contact measuring current Input impedance Contact resistance 3 20Hz max, duty cycle 50% From 0.001 to 999.9 m[3] or kWh/pulse 5VDC +/- 5% 10mA max 680 Ω ≤ 100 Ω , closed contact ≥ 500k Ω , open contact Working modes Selectable: • total and partial energy meters (kWh and kvarh) managed by time periods (t1-t2-t3-t4), W dmd synchronisation (the synchronisation is made every time the tariff changes) and GAS (m[3] ) or WATER (hot-cold m[3] ) **4** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **Digital input specifications (cont.)** **==> picture [72 x 72] intentionally omitted <==** or remote heating (kWh) meters or external kWh meter; • total and partial energy meters (kWh and kvarh) managed by time periods (t1-t2), W dmd synchronisation (the synchronisation is made independently of the tariff selection) and GAS (m[3] ) or WATER (hot-cold m[3] ) or remote heating (kWh) meters or external kWh meter; Note Insulation • total energy (kWh, kvarh) and GAS, WATER (hotcold m[3] ) and remote heating meters or external kWh meter, 3 choices only. The energy metering is only made by means of the analogue inputs. By means of optocouplers, 4000 VRMS digital inputs to measuring inputs. 4000 VRMS digital inputs to power supply input. ## **Software functions** |**Password**<br>Numeric code of max. 4<br>digits; 2 protection levels<br>of the programming data:<br>1st level<br>Password “0”, no protec-<br>tion;<br>2nd level<br>Password from 1 to 9999,<br>all data areprotected<br>**System selection**<br>System 3-Pn unbalanced load<br>3-phase (4-wire);<br>3-phase (3-wire).<br>System 3-P 1 balanced load<br>3-phase (3-wire) one cur-<br>rent and 3-phase to phase<br>voltage measurements.<br>3-phase (4-wire) one cur-<br>rent and one-phase (L1) to<br>neutral voltage measure-<br>ment.<br>System 2-P<br>2-phase (3-wire).<br>System 1-P<br>1-phase(2-wire).<br>**Transformer ratio**<br>VT (PT)<br>1.0 to 999.9 / 1000 to<br>6000.<br>CT<br>1.0 to 999.9 / 1000 to 9999<br>/ 10.00k to 60.00k.<br>Transformer ratio: VT<br>(PT): 1.0 to 999.9 / 1000<br>to 6000, CT: 1.0 to 999.9<br>/ 1000 to 9999 / 10.00k<br>to 60.00k (only AV5_X<br>and AV6_X). VT (PT) = 1.0<br>(fixed) for AV5_PF models.<br>The maximum VT by CT<br>ratio is 3150 for AV5_PF<br>models, 4629 for AV5_X<br>models.The maximum VT<br>by CT ratio is 5448 for<br>AV6_PF models, 14529<br>for AV6_X models. Note 1:<br>for MID complaint applica-<br>tions the maximum power<br>being measured is 25 MW<br>for AV5_PF models. Note<br>2: for non-MID complaint<br>applications the maximum<br>power (calculated as maxi-<br>mum input voltage and|current) being measured<br>cannot exceed 66 MW for<br>AV5_X models and 62 MW<br>for AV6_X models. If the<br>currents and/or voltages<br>being measured exceed<br>their maximum limits, the<br>display shows the error<br>message “EEEE”.<br>For EN50470-3 compliant<br>applications the maximum<br>power being measured is<br>25 MW.| |---|---| ||**Filter**<br>Operating range<br>0 to 100% of the input dis-<br>play scale<br>Filtering coefficient<br>1 to 32<br>Filter action<br>Measurements, serial out-<br>put (fundamental variables:<br>V, A, W and their derived<br>ones).| ||**Displaying**<br>Up to 3 variables per page<br>See « Display pages » 8<br>different set of variables<br>available (see « Display<br>pages ») according to the<br>application beingselected| ||**Alarm highlight**<br>In case of alarm and if the<br>relevant function is ena-<br>bled, the display changes<br>the colour alternatively<br>from white backlight to<br>blue backlight and vice<br>versa.| ||**Reset**<br>By means of the front<br>joystick:<br>- dmd and max. dmd;<br>- total energies and gas/<br>water: kWh, kvarh;<br>- partial energies and<br>tariffs: kWh,kvarh| ||**Harmonic analysis**<br>Up to the 15th harmonics<br>on single current and<br>voltage| **5** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **Software functions (cont.)** **Easy connection function** For all the display selections, both energy and power measurements are independent of the current direction. The displayed energy is always “imported” with the only exception of “F” and “H” types (see “display pages” table). **==> picture [72 x 72] intentionally omitted <==** For these latter selections the energies can be either “imported” or “exported” depending on the current direction. ## **General s ecifications p** |**Operating temperature**|-25°C to +55°C (-13°F to| |---|---| ||131°F) (R.H. from 0 to 90%| ||non-condensing @ 40°C)| ||according to EN62053-21| ||and EN62053-23| |**Storage temperature**|-30°C to +70°C (-22°F<br>to 158°F) (R.H. < 90%| ||non-condensing @ 40°C)| ||according to EN62053-21| ||and EN62053-23| |**Installation category**<br>**Insulation (for 1 minute)**|Cat. III (IEC60664,<br>EN60664)<br>4000 VRMS between meas-<br>uring inputs and power<br>supply.<br>4000 VRMS between power<br>supply and RS485 digital<br>outputs| |**Dielectric strength**<br>**Noise rejection**CMRR<br>**EMC**<br>Electrostatic discharges<br>Immunity to irradiated<br>Electromagnetic fields|4000 VRMS for 1 minute<br>100 dB,48 to 62 Hz<br>According to EN62052-11<br>15kV air discharge;<br>Test with current: 10V/m<br>from 80 to 2000MHz;<br>Test without any cur-<br>rent: 30V/m from 80 to| |Burst|2000MHz;<br>On current and voltage| ||measuring inputs circuit:| ||4kV| |Immunity to conducted|| |---|---| |disturbances|10V/m from 150KHz to| ||80MHz| |Surge|On current and voltage| ||measuring inputs circuit:| ||4kV;| |Radio frequencysuppression|Accordingto CISPR 22| |**Standard compliance**|| |Safety|IEC60664, IEC61010-1| ||EN60664, EN61010-1| ||EN62052-11| |Metrology|EN62053-21, EN50470-3,| ||EN62053-23.| |Pulse output|DIN43864, IEC62053-31| |Approvals|CE, cULus listed, MID (PF| ||option only)| |**Connections**|Screw-type| |Cable cross-section area|Max. 1.5 mm2| |**Housing**|| |Dimensions (WxHxD)|96 x 96 x 63 mm| |Material|ABS,| ||self-extinguishing: UL 94 V-0| |Mounting|Panel mounting| |**Protection degree**|| |Front|IP50| |Screw terminals|IP20| |**Weight**|Approx. 400 g (packing| ||included)| ## **Power su l s ecifications pp y p** **Auxiliary power supply** H: 90 to 260VAC/DC (48 to 62Hz) **Power consumption** AC: 6VA DC: 3.5 W **6** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **Accuracy (according to EN50470-3 and EN62053-23)** **==> picture [490 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> kWh , accuracy (RDG) depending on the current kvarh , accuracy (RDG) depending on the current<br>Percentage error limits for class index B<br>+1.5% +2,5%<br>+1% +2%<br>0% 0%<br>-1% -2%<br>-1,5% -2,5%<br>a a eer<br>PF=1 0.05A (Imin) 0.25A (Itr) 5A (In) 10A (Imax) sin j =1 0.1A 0.25A 5A (In) 10A (Imax)<br>PF=L0.5 0.25A (Itr) 5A (In) 10A (Imax) sin j =0.5 0.25A 0.5A 5A (In) 10A (Imax)<br>or C0.8<br>Accuracy limits (Active energy) Accuracy limits (Reactive energy)<br>Start-up current: 10mA Start-up current: 10mA<br>**----- End of picture text -----**<br> ## **MID compliance (PF option only)** **Accuracy** 0.9 Un ≤ U ≤ 1.1 Un; 0.98 fn ≤ f ≤ 1.02 fn; fn: 50Hz; cos j : 0.5 inductive to 0.8 capacitive. AV5-AV6 models Class B. I st: 0.01A; I min: 0.05A; I tr: 0.25A; I n: 5A; I max: 10A **Operating temperature** -25°C to +55°C (-13°F to 131°F) (R.H. from 0 to 90% non-condensing @ 40°C) |**EMC compliance**<br>**Mechanical compliance**|E2<br>M2| |---|---| |**Protection degree**|in order to achieve the<br>protection against dust<br>and water required by the<br>norms harmonized to MID,<br>the meter must be used<br>only installed in IP51 (or<br>better) cabinets.| ## **Used calculation formulas** ## **Phase variables** ## **System variables** ## **Energy metering** Instantaneous effective voltage > Instantaneous active power hy fa God m ~~L~~ SOA) Instantaneous power factor ## PF Instantaneous effective current Instantaneous apparent power Equivalent three-phase voltage bap ep Three-phase reactive power ~~a~~ var, = (var, + var, + var, ) Three-phase active power Three-phase apparent power Three-phase power factor (TPF) Where: **P** = active power; **Q** = reactive power; **t1, t2** =starting and ending time points of consumption recording; **nj** = time unit; ∆ **t** = time interval between two successive power consumptions; **n1, n2** = starting and ending discrete time points of consumption recording Instantaneous reactive power Where: **n** = sample number **7** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **List of the variables that can be connected to:** **==> picture [72 x 72] intentionally omitted <==** ## • RS485 communication port - Alarm outputs (“max” variable”, “energies” and “hour counter” excluded) • Pulse outputs (only positive “energies”) |**No**|**Variable**|**1-phase**<br>**system**|**2-phase**<br>**system**|**3-ph. 4-wire**<br>**balanced sys.**|**3-ph. 4-wire**<br>**unbal. sys.**|**3 ph. 3-wire**<br>**bal. sys.**|**3 ph. 3-wire**<br> <br>**unbal. sys.**|**Notes**| |---|---|---|---|---|---|---|---|---| |1|V L-N sys||x|x|x|x|x<br>|sys=system| |2|<br>V L1|x|x|x|x|x|<br>x|| |3|V L2|o|x|x|x|x|x|| |4|V L3|o|o|x|x|x|x|| |5|V L-L sys|o|x|x|x|x|x<br>|sys=system| |6|<br>V L1-2|o|x|x|x|x|<br>x|| |7|V L2-3|o|o|x|x|x|x|| |8|V L3-1|o|o|x|x|x|x|| |9|A dmd max||x|x|x|x|x<br> <br> <br>|Highest “dmd”<br>current among<br>the phases (1)| |10|A L1|x|x|x|x|x|<br>x|| |11|A L2|o|x|x|x|x|x|| |12|A L3|o|o|x|x|x|x|| |13|VA sys|x|x|x|x|x|x<br>|sys=system| |14|<br>VA sys dmd|x|x|x|x|x|<br>x<br>|<br>sys=system (1)| |15|<br>VA L1|x|x|x|x|x|<br>x|| |16|VA L2|o|x|x|x|x|x|| |17|VA L3|o|o|x|x|x|x|| |18|var sys|x|x|x|x|x|x<br>|sys=system| |19|<br>var L1|x|x|x|x|x|<br>x|| |20|var L2|o|x|x|x|x|x|| |21|var L3|o|o|x|x|x|x|| |22|W sys|x|x|x|x|x|x<br>|sys=system| |23|<br>W sys dmd|x|x|x|x|x|<br>x<br>|<br>sys=system (1)| |24|<br>W L1|x|x|x|x|x|<br>x|| |25|W L2|o|x|x|x|x|x|| |26|W L3|o|o|x|x|x|x|| |27|PF sys|x|x|x|x|x|x|| |28|<br>PF L1|x|x|x|x|x|x|| |29|PF L2|o|x|x|x|x|x|| |30|PF L3|o|o|x|x|x|x|| |31|Hz|x|x|x|x|x|x|| |32|Phase seq.|o|o|x|x|x|x|| |33|<br>Hours|x|x|x|x|x|x|| |34|kWh (+)|x|x|x|x|x|x<br>|Total or by user| |35|<br>kvarh (+)|x|x|x|x|x|<br>x<br>|<br>Total or by user| |36|<br>kWh (+)|x|x|x|x|x|<br>x<br>|<br>Partial or by tariff| |37|<br>kvarh (+)|x|x|x|x|x|<br>x<br>|<br>Partial or by tariff| |38|<br>kWh (-)|x|x|x|x|x|<br>x<br>|<br>Total| |39|<br>kvarh (-)|x|x|x|x|x|x|Total| |40|<br>m3Gas|x|x|x|x|x|x<br>|Total| |41|m3Cold H2O|x|x|x|x|x|x<br>|Total| |42|m3Hot H2O|x|x|x|x|x|x<br>|Total| |43|kWh H2O|x|x|x|x|x|x<br>|Total| |44|kWh out|x|x|x|x|x|x<br>|Total| |45|A L1 THD|x|x|x|x|x|x|| |46|A L2 THD|o|x|x|x|x|x|| |47|A L3 THD|o|o|x|x|x|x|| |48|V L1 THD|x|x|x|x|x|x|| |49|V L2 THD|o|x|x|x|x|x|| |50|V L3 THD|o|o|x|x|x|x|| |51|V L1-2 THD|x|x|x|x|x|x|| |52|V L2-3 THD|o|x|x|x|x|x|| |||||||||| |53<br>V L3-1 THD<br>o<br>o<br>x<br>x<br>x<br>x||||||||| (x) = available; (o) = not available (zero indication on the display); (1) Max. value with data storage. **8** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **Display pages** **==> picture [72 x 72] intentionally omitted <==** **==> picture [499 x 587] intentionally omitted <==** **----- Start of picture text -----**<br> Sel. 1st variable 2nd variable 3rd variable Applications<br>No Note<br>pos. (1st line) (2nd line) (3rd line) A B C D E F G H<br>1 Total kWh (+) W sys dmd W sys dmd max x x x x x x x<br>2 kWh (+) A dmd max “PArt” “PArt” = Partial kWh (+) x x x<br>3 Total kvarh (+) VA sys dmd VA sys dmd max x x x x x<br>4 kvarh (+) VA sys “PArt” “PArt” = Partial kvarh (+) x x x<br>5 Totalizer 1 (2) W sys (text) (3) (1) x x x x<br>6 Totalizer 2 (2) W sys (text) (3) (1) x x x x<br>7 Totalizer 3 (2) W sys (text) (3) (1) x x x x<br>8 kWh (+) t1 (text) (4) W sys dmd (1) digital input enabled x x x x<br>9 kWh (+) t2 (text) (4) W sys dmd (1) digital input enabled x x x x<br>10 kWh (+) t3 (text) (4) W sys dmd (1) digital input enabled x x x x<br>11 kWh (+) t4 (text) (4) W sys dmd (1) digital input enebled x x x x<br>12 kvarh (+) t1 (text) (4) W sys dmd (1) digital input enabled x x x x<br>13 kvarh (+) t2 (text) (4) W sys dmd (1) digital input enabled x x x x<br>14 kvarh (+) t3 (text) (4) W sys dmd (1) digital input enabled x x x x<br>15 kvarh (+) t4 (text) (4) W sys dmd (1) digital input enabled x x x x<br>16 kWh (+) X W X User X (1) specific function enabled x<br>17 kWh (+) Y W Y User Y (1) specific function enabled x<br>18 kWh (+) Z W Z User Z (1) specific function enabled x<br>19 Total kvarh (-) VA sys dmd VA sys dmd max x x<br>20 Total kWh (-) W sys dmd W sys dmd max x x x<br>21 Hours W sys PF sys x x x x<br>22 Hours var sys PF sys x x x x<br>23 W L1 W L2 W L3 x x x<br>24 VA L1 VA L2 VA L3 x x<br>25 var L1 var L2 var L3 x x<br>26 PF L1 PF L2 PF L3 x x<br>27 V L1 V L2 V L3 x x x x x<br>28 V L1-2 V L2-3 V L3-1 x x<br>29 A L1 A L2 A L3 x x x<br>30 Phase seq. V LN sys Hz x x x x x x x<br>31 Phase seq. V LL sys Hz x x x<br>32 ASY V LL sys % x x x<br>33 ASY V LN sys % x x x<br>34 THD A1 THD A2 THD A3 x x<br>35 THD V1 THD V2 THD V3 x x<br>36 THD V12 THD V23 THD V 31 x x<br>37 Lot number Year DMD time x x x x x x x x<br>38 CT ratio Value of CT System x x x x x x x x<br>39 VT/PT ratio Value of VT Connection x x x x x x x x<br>40 a Alarm 1 status Set-point value Variable type x x x x<br>41 a Alarm 2 status Set-point value Variable type x x x x<br>42 a Alarm 3 status Set-point value Variable type x x x x<br>40 b Pulse 1 status Output pulse x x x x x x x x<br>41 b Pulse 2 status Output pulse x x x x x x x x<br>42 b Pulse 3 status Output pulse x x x x x x x x<br>43 Serial port Address RS485 status x x x x x x x x<br>0 Selector position which can be linked to any of the variable combinations listed above (No. from 1 to 36)<br>1 Selector position which can be linked to any of the variable combinations listed above (No. from 1 to 36)<br>2 Selector position which can be linked to any of the variable combinations listed above (No. from 1 to 36)<br>Selector position which can be linked to any of the variable combinations listed above (No. from 1 to 36).<br>3<br>In this position the front LED blinks proportionally to the reactive energy (kvarh) being measured<br>**----- End of picture text -----**<br> **(1)** The page is available according to the enabled measurement. **(2)** m[3] Gas, m[3] Water, kWh remote heating, external kWh counter. **(3)** Hot or Cold (water), gas, ENE (external energy meter). **(4)** The active tariff is displayed with an “A” before the “t1-t2-t3-t4” simbols. **9** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **Additional available information on the dis la p y** |**Type**|**1st line**|**2nd line**|**3rd line**| |---|---|---|---| |Meter information pag. 1|Firmware release|Year|Year of production| |Meter information pag. 2|Pulse|LED|Value| |Meter information pag. 3|System|2w, 3w or 4w|| |Meter information pag. 4|CT ratio|Value of CT ratio|| |Meter information pag. 5|PT ratio|Value of PT ratio|| |In case of alarm output<br>pag.6a|Alarm output 1, 2 or 3 status<br>(ON/OFF)|Set-point value|Variable type| |pag.6a<br>In case of pulse output<br>pag. 6b|(ON/OFF)<br>Pulse output 1,2 or 3 variable<br>link(kWh/kvarh)|Output pulse weight (kWh/<br>kvarh per pulse)|| |pag. 6b<br>In case of communication<br>port pag.7|Serial port|kvarh per pulse)<br>Address|RS485 status (RX-TX)| |port pag.7<br>In case of communication<br>port pag.8|Secondary address<br>(for M-bus protocol)|Sn|| ## **List of selectable a lications pp** ||**Description**|**Notes**| |---|---|---| |**A**|Basic domestic******|Main energy metering| |**B**|Shopping centres******|Main energy metering| |**C**|Advanced domestic******|Main energy metering (total and based on tariff), gas and<br>water metering| |**D**|Multi domestic (also camping and marinas)***/ ****|Main energy metering (3 by single phase)| |**E**|Solar*****|Energy meter with some basic power analyzer functions| |**F**|Industrial*****|Main energy metering| |**G**|Advanced industrial******|Energy metering and power analysis| |**H**|Advanced industrial for power generation*****|Complete energy metering and power analysis| **Notes** : ***** Not available with option PF A. ****** Not available with option PF B ## **Insulation between inputs and outputs** ||Measuring Inputs|Relay<br>output|Open collector<br>outputs|Comm. port|Digital inputs|Auxiliary power supply| |---|---|---|---|---|---|---| |Measuring Inputs|-|4kV|4kV|4kV|4kV|4kV| |Relay output|4kV|-|-|4kV|-|4kV| |Open collector<br>outputs<br>Comm. port|4kV<br>4kV|-<br>4kV|-<br>4kV|4kV<br>-|-<br>4kV|4kV<br>4kV| |Digital inputs|4kV|-|-|4kV|-|4kV| |Aux. power supply|4kV|4kV|4kV|4kV|4kV|-| **NOTE:** all the models with auxiliary power supply have, mandatory, to be connected to external current transformers because the insulation among the current inputs is just functional (100VAC). ## **Tam er roof and dis la a e selection p p p y p g** Lock of programming with seal. Selection of up to 4 main pages (programmable by the user). Easy access to specific display pages. **10** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **Wiring diagrams** **==> picture [72 x 72] intentionally omitted <==** ## **System type selection: 3P.n** **==> picture [155 x 153] intentionally omitted <==** **==> picture [330 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> 3-ph, 4-wire, unbalanced load Fig. 1 3-ph, 4-wire, unbalanced load Fig. 2<br>3-CT connection 3-CT and 3-VT/PT connections<br>**----- End of picture text -----**<br> ## **System type selection: 3P.n** **==> picture [500 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> 3-ph, 3-wire, unbalanced load Fig. 3 3-ph, 3-wire, unbalanced load Fig. 4 3-ph, 3-wire, unbalanced load Fig. 5<br>3-CT connection 3-CT and 2-VT/PT connections 2-CT connections (ARON)<br>**----- End of picture text -----**<br> ## **System type selection: 3P.1** **==> picture [499 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> 3-ph, 3-wire, unbalanced load Fig. 6 3-ph, 3-wire, balanced load Fig. 7 3-ph, 3-wire, balanced load Fig. 8<br>1-CT connection<br>NOTE: a 2-wire connection for voltage measure-<br>2-CT and 2-VT/PT connections ARON ment is available across 15 and 17 . 1-CT and 2-VT/PT connections<br>**----- End of picture text -----**<br> **11** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **Wiring diagrams** **==> picture [72 x 72] intentionally omitted <==** **==> picture [500 x 193] intentionally omitted <==** **----- Start of picture text -----**<br> System type selection: 2P System type selection: 1P<br>2-ph, 3-wire Fig. 9 2-ph, 3-wire Fig. 10 1-ph, 2-wire Fig. 11<br>2-CT connection 2-CT and 2-VT/PT connections 1-CT connection<br>**----- End of picture text -----**<br> ## **System type selection: 1P** ## **Auxiliary power supply wiring diagrams** **==> picture [329 x 171] intentionally omitted <==** **----- Start of picture text -----**<br> 1-ph, 2-wire Fig. 12 100 to 230VAC/DC (“H” option) Fig.13<br>1-CT and 1-VT connections F= 250V [T] 100mA<br>**----- End of picture text -----**<br> ## **Digital inputs and RS485 port wiring diagrams** **==> picture [499 x 114] intentionally omitted <==** **----- Start of picture text -----**<br> Digital Inputs RS485 port<br>**----- End of picture text -----**<br> **RS485 NOTE:** additional devices provided with RS485 are connected in parallel. The termination of the serial output is carried out only on the last instrument of the network, by means of a jumper between (A-) and (T). **12** Specifications are subject to change without notice EM2696 DS ENG 130117 **EM26 96** ## **O en collector and rela out uts wirin dia rams p y p g g** **==> picture [408 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> Open Collector Open Collector Relay<br>© O ® O4 0 @ ® O ® M 0 ®<br>1 2 3 1 2 3<br>GND reference VDC reference<br>Out 1 VDC GND Out 2 VDC GND Out 3 VDC GND VDC Out 1 GND VDC Out 2 GND VDC Out 3 GND<br>RC RC RC RC RC RC<br>**----- End of picture text -----**<br> The load resistances (RC) must be designed so that the close contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC. ## **Front anel descri tion p p** **1. Display** - LCD-type with alphanumeric indications to: - display configuration parameters; **==> picture [186 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> mw e y 0 1<br>ao NGS<br>Aaa [ = ow Nee<br>2 3<br>rt t w<br>4<br>= Energy Analyzer EM26-96 O<br>**----- End of picture text -----**<br> - display all the measured variables. **2. Selector** - To select the desired display pages and to lock the programming. **3. Joystick** - To program the configuration parameters and scroll the variables on the display. **4. LED** - Red LED blinking proportionally to the energy being measured. ## **Dimensions and Panel Cut-out** **==> picture [156 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> WA So<br>91mm<br>f g<br>**----- End of picture text -----**<br> **13** Specifications are subject to change without notice EM2696 DS ENG 130117
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →