Image not available
Illustrative purposes only
ELG-200-48DA
LED Driver, LED Lighting, 199.68 W, 48 VDC, 4.16 A, Constant Current, Constant Voltage, 100 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (25-Jun-2025)
- Product Range: ELG-200
- Output Current: 4.16A
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 199.68W
- Input Voltage Max: 305VAC
- Input Voltage Min: 100VAC
- Output Voltage Max: 48VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 47.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [512 x 763] intentionally omitted <==** |**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>500ms, 100ms/230VAC, 1000ms, 100ms/115VAC<br>10ms/ 230VAC 10ms/ 115VAC<br>47 ~ 63Hz<br>1.8A / 115VAC 1.2A / 230VAC 1.0A/277VAC<br><0.75mA / 277VAC<br>Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;GB17625.1,GB17743<br>≧<br>;EAC TP TC 020; KC KN15 KN61547<br>,<br>20 ~ 95% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>90℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down output voltage, re-power on to recover<br>Shut down output voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.6**<br>**HOLD UP TIME (Typ.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>**CONSTANT CURRENT REGION Note.2**<br>**OVER CURRENT**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>COLD START 60A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>510μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (<br>)<br>surge immunity Line-Earth 6KV, Line-Line 4KV ;EAC TP TC 020; KC KN15 KN61547<br>,<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC<br>℃<br>.<br>℃<br>℃<br>℃<br>95 ~ 108%<br>Hiccup mode, recovers automatically after fault condition is removed<br>Constant current limiting, recovers automatically after fault condition is removed<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>No load power consumption <0.5W for Blank / A / Dx / D-Type<br>**NO LOAD / STANDBY**<br>**POWER CONSUMPTION Note.7** Standby power consumption <0.5W for B / AB / DA-Type<br>Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**ELG-200-54**<br>**ELG-200-48**<br>**ELG-200-36**<br>**ELG-200-12**<br>**ELG-200-42**<br>54V<br>48V<br>36V<br>12V<br>42V<br>16A<br>4.76A<br>5.55A<br>4.16A<br>350mVp-p<br>27 ~ 54V<br>200.88W<br>3.72A<br>250mVp-p<br>24 ~ 48V<br>199.68W<br>250mVp-p<br>18 ~ 36V<br>199.8W<br>150mVp-p<br>6 ~ 12V<br>192W<br>250mVp-p<br>21 ~ 42V<br>199.9W<br>11.2 ~ 12.8V<br>33.5 ~ 38.5V<br>39 ~ 45V<br>44.8 ~ 51.2V<br>50 ~ 57V<br>1.86 ~ 3.72A<br>2.08 ~ 4.16A<br>2.78 ~ 5.55A<br>8 ~ 16A<br>2.38 ~ 4.76A<br>±3.0%<br>±0.5%<br>±2.0%<br>±2.0%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>93%<br>93%<br>92%<br>90%<br>92.5%<br>60 ~ 67V<br>54 ~ 63V<br>42 ~ 49V<br>13.5 ~ 18V<br>47 ~ 54V<br>244 71<br>*<br>*37.5mm (L*W*H)<br>1.22Kg; 12pcs / 15.2Kg / 0.72CUFT<br>**ELG-200-24**<br>24V<br>8.4A<br>200mVp-p<br>12 ~ 24V<br>201.6W<br>4.2 ~ 8.4A<br>±2.0%<br>±0.5%<br>±0.5%<br>92%<br>27 ~ 34V<br>22.4 ~ 25.6V<br>**SAFETY STANDARDS**<br>UL8750<br>independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;IEC/EN/AS/NZS 61347-1, IEC/EN/AS/NZS 61347-2-13<br>EAC TP TC 004;BIS IS15885(for 12/12B/24/24B/36/36A/42A/48/48A/54A only) GB19510.14,GB19510.1; IP65 or IP67;<br>;<br>approved<br>KC61347 1 KC61347 2 13<br>- ,<br>- -<br>Compiy with IEC62386-101,102,207 for DA-Type only<br>**DALI STANDARDS**<br>826.7K hrs min.<br>Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>150W<br>144W<br>149.94W<br>149.76W<br>149.76W<br>150.12W<br>200VAC ~ 305VAC<br>100VAC ~ 180VAC<br>~~———~~<br>~~—————~~<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _ ofambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7. No load/standby power consumption<br>is specified for 230VAC inpu<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. This series meetsthe typical lifeexpectancy of>50,000 hours of operation when Tcase, particularly(©)point (orTMP, per DLC), is about 70<br>or less.<br>10.Please refer to the warranty statement on MEAN WELL's website at ~~http:/Awww.meanwell.com~~<br>11.The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)|<br>12.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https:/Avww.meanwell.com/Upload/PDF/LED_EN.pdf|**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>500ms, 100ms/230VAC, 1000ms, 100ms/115VAC<br>10ms/ 230VAC 10ms/ 115VAC<br>47 ~ 63Hz<br>1.8A / 115VAC 1.2A / 230VAC 1.0A/277VAC<br><0.75mA / 277VAC<br>Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;GB17625.1,GB17743<br>≧<br>;EAC TP TC 020; KC KN15 KN61547<br>,<br>20 ~ 95% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>90℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down output voltage, re-power on to recover<br>Shut down output voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**VOLTAGE ADJ. RANGE**<br>**CURRENT ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.6**<br>**HOLD UP TIME (Typ.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>**CONSTANT CURRENT REGION Note.2**<br>**OVER CURRENT**<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>Adjustable for A/AB-Type only (via built-in potentiometer)<br>COLD START 60A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>510μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (<br>)<br>surge immunity Line-Earth 6KV, Line-Line 4KV ;EAC TP TC 020; KC KN15 KN61547<br>,<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC<br>℃<br>.<br>℃<br>℃<br>℃<br>95 ~ 108%<br>Hiccup mode, recovers automatically after fault condition is removed<br>Constant current limiting, recovers automatically after fault condition is removed<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>No load power consumption <0.5W for Blank / A / Dx / D-Type<br>**NO LOAD / STANDBY**<br>**POWER CONSUMPTION Note.7** Standby power consumption <0.5W for B / AB / DA-Type<br>Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**ELG-200-54**<br>**ELG-200-48**<br>**ELG-200-36**<br>**ELG-200-12**<br>**ELG-200-42**<br>54V<br>48V<br>36V<br>12V<br>42V<br>16A<br>4.76A<br>5.55A<br>4.16A<br>350mVp-p<br>27 ~ 54V<br>200.88W<br>3.72A<br>250mVp-p<br>24 ~ 48V<br>199.68W<br>250mVp-p<br>18 ~ 36V<br>199.8W<br>150mVp-p<br>6 ~ 12V<br>192W<br>250mVp-p<br>21 ~ 42V<br>199.9W<br>11.2 ~ 12.8V<br>33.5 ~ 38.5V<br>39 ~ 45V<br>44.8 ~ 51.2V<br>50 ~ 57V<br>1.86 ~ 3.72A<br>2.08 ~ 4.16A<br>2.78 ~ 5.55A<br>8 ~ 16A<br>2.38 ~ 4.76A<br>±3.0%<br>±0.5%<br>±2.0%<br>±2.0%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>±2.0%<br>±0.5%<br>±0.5%<br>93%<br>93%<br>92%<br>90%<br>92.5%<br>60 ~ 67V<br>54 ~ 63V<br>42 ~ 49V<br>13.5 ~ 18V<br>47 ~ 54V<br>244 71<br>*<br>*37.5mm (L*W*H)<br>1.22Kg; 12pcs / 15.2Kg / 0.72CUFT<br>**ELG-200-24**<br>24V<br>8.4A<br>200mVp-p<br>12 ~ 24V<br>201.6W<br>4.2 ~ 8.4A<br>±2.0%<br>±0.5%<br>±0.5%<br>92%<br>27 ~ 34V<br>22.4 ~ 25.6V<br>**SAFETY STANDARDS**<br>UL8750<br>independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;IEC/EN/AS/NZS 61347-1, IEC/EN/AS/NZS 61347-2-13<br>EAC TP TC 004;BIS IS15885(for 12/12B/24/24B/36/36A/42A/48/48A/54A only) GB19510.14,GB19510.1; IP65 or IP67;<br>;<br>approved<br>KC61347 1 KC61347 2 13<br>- ,<br>- -<br>Compiy with IEC62386-101,102,207 for DA-Type only<br>**DALI STANDARDS**<br>826.7K hrs min.<br>Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>150W<br>144W<br>149.94W<br>149.76W<br>149.76W<br>150.12W<br>200VAC ~ 305VAC<br>100VAC ~ 180VAC<br>~~———~~<br>~~—————~~<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _ ofambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7. No load/standby power consumption<br>is specified for 230VAC inpu<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. This series meetsthe typical lifeexpectancy of>50,000 hours of operation when Tcase, particularly(©)point (orTMP, per DLC), is about 70<br>or less.<br>10.Please refer to the warranty statement on MEAN WELL's website at ~~http:/Awww.meanwell.com~~<br>11.The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)|<br>12.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https:/Avww.meanwell.com/Upload/PDF/LED_EN.pdf|**ELG-200-12**|**ELG-200-24**|**ELG-200-36**|**ELG-200-42**|**ELG-200-48**|**ELG-200-54**| |---|---|---|---|---|---|---|---| ||**DC VOLTAGE**<br>~~———~~|12V<br>~~———~~|24V<br>~~———~~|36V<br>~~———~~|42V<br>~~———~~|48V<br>~~———~~|54V<br>~~———~~| ||**CONSTANT CURRENT REGION Note.2**<br>~~———~~|6 ~ 12V<br>~~———~~|12 ~ 24V<br>~~———~~|18 ~ 36V<br>~~———~~|21 ~ 42V<br>~~———~~|24 ~ 48V<br>~~———~~|27 ~ 54V<br>~~———~~| ||**RATED CURRENT**<br>~~———~~|16A<br>~~———~~|8.4A<br>~~———~~|5.55A<br>~~———~~|4.76A<br>~~———~~|4.16A<br>~~———~~|3.72A<br>~~———~~| ||**RATED POWER**<br>~~———~~|200.88W<br>199.68W<br>199.8W<br>192W<br>199.9W<br>201.6W<br>150W<br>144W<br>149.94W<br>149.76W<br>149.76W<br>150.12W<br>200VAC ~ 305VAC<br>100VAC ~ 180VAC<br>~~———~~|||||| ||**RIPPLE & NOISE (max.) Note.3**<br>~~———~~|150mVp-p<br>~~———~~|200mVp-p<br>~~———~~|250mVp-p<br>~~———~~|250mVp-p<br>~~———~~|250mVp-p<br>~~———~~|350mVp-p<br>~~———~~| ||**VOLTAGE ADJ. RANGE**<br>~~———~~|Adjustable for A/AB-Type only (via built-in potentiometer)<br>11.2 ~ 12.8V<br>33.5 ~ 38.5V<br>39 ~ 45V<br>44.8 ~ 51.2V<br>50 ~ 57V<br>22.4 ~ 25.6V<br>~~———~~|||||| ||**CURRENT ADJ. RANGE**<br>~~———~~|Adjustable for A/AB-Type only (via built-in potentiometer)<br>1.86 ~ 3.72A<br>2.08 ~ 4.16A<br>2.78 ~ 5.55A<br>8 ~ 16A<br>2.38 ~ 4.76A<br>4.2 ~ 8.4A<br>~~———~~|||||| ||**VOLTAGE TOLERANCE Note.4**<br>~~———~~|±3.0%<br>~~———~~|±2.0%<br>~~———~~|±2.0%<br>~~———~~|±2.0%<br>~~———~~|±2.0%<br>~~———~~|±2.0%<br>~~———~~| ||**LINE REGULATION**<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~| ||**LOAD REGULATION**<br>~~———~~|±2.0%<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~|±0.5%<br>~~———~~| ||**SETUP, RISE TIME**<br>**Note.6**<br>~~———~~|500ms, 100ms/230VAC, 1000ms, 100ms/115VAC<br>~~———~~|||||| ||**HOLD UP TIME (Typ.)**<br>~~———~~|10ms/ 230VAC 10ms/ 115VAC<br>~~———~~|||||| ||**VOLTAGE RANGE**<br>**Note.5**|(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC|||||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||||| ||**POWER FACTOR**|PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)|||||| ||**TOTAL HARMONIC DISTORTION**|THD< 20%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)|||||| ||**EFFICIENCY (Typ.)**|90%|92%|92%|92.5%|93%|93%| ||**AC CURRENT**|1.8A / 115VAC 1.2A / 230VAC 1.0A/277VAC|||||| ||**INRUSH CURRENT(Typ.)**|COLD START 60A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>510μ<br>;Per NEMA 410|||||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC|||||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC|||||| ||**NO LOAD / STANDBY**<br>**POWER CONSUMPTION Note.7**|No load power consumption <0.5W for Blank / A / Dx / D-Type<br> Standby power consumption <0.5W for B / AB / DA-Type|||||| ||**OVER CURRENT**|95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed|||||| ||**SHORT CIRCUIT**|Hiccup mode, recovers automatically after fault condition is removed|||||| ||**OVER VOLTAGE**|Shut down output voltage, re-power on to recover<br>60 ~ 67V<br>54 ~ 63V<br>42 ~ 49V<br>13.5 ~ 18V<br>47 ~ 54V<br>27 ~ 34V|||||| ||**OVER TEMPERATURE**|Shut down output voltage, re-power on to recover|||||| ||**WORKING TEMP.**|Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃|||||| ||**MAX. CASE TEMP.**|Tcase=+90℃|||||| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +<br>, 10 ~ 95% RH<br>90℃|||||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||||| ||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||||| ||**SAFETY STANDARDS**|UL8750<br>independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;IEC/EN/AS/NZS 61347-1, IEC/EN/AS/NZS 61347-2-13<br>EAC TP TC 004;BIS IS15885(for 12/12B/24/24B/36/36A/42A/48/48A/54A only) GB19510.14,GB19510.1; IP65 or IP67;<br>;<br>approved<br>KC61347 1 KC61347 2 13<br>- ,<br>- -|||||| ||**DALI STANDARDS**|Compiy with IEC62386-101,102,207 for DA-Type only|||||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC|||||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||||| ||**EMC EMISSION**|Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;GB17625.1,GB17743<br>≧<br>;EAC TP TC 020; KC KN15 KN61547<br>,|||||| ||**EMC IMMUNITY**<br>~~—————~~|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (<br>)<br>surge immunity Line-Earth 6KV, Line-Line 4KV ;EAC TP TC 020; KC KN15 KN61547<br>,<br>~~—————~~|||||| ||**MTBF**<br>~~—————~~|826.7K hrs min.<br>Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~—————~~|||||| ||**DIMENSION**<br>~~—————~~|244 71<br>*<br>*37.5mm (L*W*H)<br>~~—————~~|||||| ||**PACKING**<br>~~—————~~|1.22Kg; 12pcs / 15.2Kg / 0.72CUFT<br>~~—————~~|||||| ||℃<br>.<br>℃<br>℃<br>℃<br>~~—————~~<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _ ofambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7. No load/standby power consumption<br>is specified for 230VAC inpu<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. This series meetsthe typical lifeexpectancy of>50,000 hours of operation when Tcase, particularly(©)point (orTMP, per DLC), is about 70<br>or less.<br>10.Please refer to the warranty statement on MEAN WELL's website at ~~http:/Awww.meanwell.com~~<br>11.The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)|<br>12.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https:/Avww.meanwell.com/Upload/PDF/LED_EN.pdf||||||| ## **SPECIFICATION** **NOTE** . ℃ ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** ## **Block Diagram** **==> picture [464 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>EMI FILTER PFC POWER RECTIFIERS Vo+<br>I/P & CIRCUIT SWITCHING & Vo-<br>RECTIFIERS FILTER<br>O.L.P.<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>PFC CONTROL<br>O.V.P.<br>CASE :Protective Earth<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** - ※ This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs. **==> picture [216 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>(B)<br>(A) Constant<br>Constant<br>Current area<br>Voltage area<br>50<br>(min.)<br>(C)<br>Hiccup<br>Protection<br>50 100 Io(%)<br>Typical output current normalized by rated current (%)<br>Vo(%)<br>**----- End of picture text -----**<br> In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Should there be any compatibility issues, please contact MEAN WELL. _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** ## **DIMMING OPERATION** **==> picture [471 x 620] intentionally omitted <==** **----- Start of picture text -----**<br> Vo-(Black)<br>ACN(Blue) ELG-200 Vo+(Red)<br>ACL(Brown) DIM+(Blue)*<br>DIM-(White)**<br>* DIM+ for B/AB-Type<br>※ 3 in 1 dimming function (for B/AB-Type) DA+ for DA-TypePROG+ for D2-Type<br>�Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: * *DIM- for B/AB-Type<br>DA- for DA-Type<br>0 ~ 10VDC, or 10V PWM signal or resistance. PROG- for D2-Type<br>�Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.<br>�Dimming source current from power supply: 100μA (typ.)<br>◎ Applying additive 0 ~ 10VDC 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>◎ Applying additive resistance: 100%<br>90%<br>Vo+ + + 80%<br>70%<br>-<br>Vo- - 60%<br>DIM+ 50%<br>40%<br>Additive Resistance<br>30%<br>DIM- 20%<br>“DO NOT connect "DIM- to Vo-" 10%<br>0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.<br>2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> _File Name:ELG-200-SPEC 2018-09-30_ ## 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** - ※ **DALI Interface (primary side; for DA-Type)** Apply DALI signal between DA+ and DA-. - DALI protocol comprises 16 groups and 64 addresses. First step is fixed at 8% of output. - ※ **Smart timer dimming function (for Dxx-Type by User definition)** MEAN WELL Smart timer dimming primarily provides the adaptive proportion dimming profile for the output constant current level to perform up to 14 consecutive hours. 3 dimming profiles hereunder are defined accounting for the most frequently seen applications. If other options may be needed, please contact MEAN WELL for details. **==> picture [209 x 123] intentionally omitted <==** **----- Start of picture text -----**<br> Ex : ◎ D01-Type: the profile recommended for residential lighting<br>100iere |<br>||<br>ue |<br>- ||<br>40<br>30<br>Dimming Level(%)<br>**----- End of picture text -----**<br> ||T1|T2|T3|T4| |---|---|---|---|---| |TIME**|06:00|07:00|11:00|---| |LEVEL**|100%|70%|50%|70%| Operating Time(HH:MM) **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a residential lighting application adopts D01-Type, when turning on the power supply at 6:00pm, for instance: [1] The power supply will switch to the constant current level at 100% starting from 6:00pm. [2] The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on. The constant current level remains till 8:00am, which is 14:00 after the power supply turns on. Ex: ◎ D02-Type: the profile recommended for street lighting 100_i | 80 70 | el | so 40 30 Set up for D02-Type in Smart timer dimming software program: ||T1|T2|T3|T4|T5| |---|---|---|---|---|---| |TIME**|01:00|03:00|8:00|11:00|---| |LEVEL**|50%|80%|100%|60%|80%| ## Operating Time(HH:MM) **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance: [1] The power supply will switch to the constant current level at 50% starting from 5:00pm. [2] The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on. [5] The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on. _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** |Ex:|◎|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|D03-Type: the profile recommended for tunnel lighting|||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||100||||||||||||||| |||90||||||||Set up for D03-Type in Smart timer dimming software program:|||||| |||80|||||||||||||| |Dimming Level(%)||70<br>60<br>50<br>40<br>30|||||||||TIME**<br>LEVEL**|01:30<br>T1<br>70%|T2<br>11:00<br>100%|T3<br>---<br>70%|| |||20|||||||||||||| |||10|||||||||||||| |||0|||||||||||||| |||00:00|02:00|04:00|06:00|08:00|10:00|12:00|14:00||||||| ||||||Operating Time(HH:MM)|Operating Time(HH:MM)|||||||||| **: TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level. Example: If a tunnel lighting application adopts D03-Type, when turning on the power supply at 4:30pm, for instance: [1] The power supply will switch to the constant current level at 70% starting from 4:30pm. [2] The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on. [3] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on. _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** ## **OUTPUT LOAD vs TEMPERATURE(Note.10)** **==> picture [498 x 384] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>others<br>80 80<br>230VAC 230VAC<br>input only 12V input only<br>60 60<br>40 110VAC 40 110VAC<br>20 20<br>-40 -25 0 10 20 30 50 60 70 (HORIZONTAL) -40 -25 0 20 45 55 65 75 90 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>◎ If ELG-200 operates in Constant Current mode with the<br>rated current, the maximum workable Ta is 50℃ for<br>12V-model whereas 60℃ for other models.<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 80℃<br>Constant Current Mode<br>100<br>90 1<br>0.98<br>80<br>75 0.96<br>70 0.94<br>60 0.92 277V(200W)<br>0.9 230V(200W)<br>50<br>0.88 115V(150W)<br>40<br>0.86<br>0.84<br>100 120 140 160 180 200 240 250 260 270 280 305 50% 60% 70% 80% 90% 100%<br>INPUT VOLTAGE (V) 60Hz<br>LOAD<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>**----- End of picture text -----**<br> - ※De-rating is needed under low input voltage. ## **TOTAL HARMONIC DISTORTION (THD)** - ※ 48V Model, Tcase at 80℃ **==> picture [241 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> 18%<br>16%<br>14%<br>12% 277V(200W)<br>230V(200W)<br>10% 115V(150W)<br>8%<br>6%<br>4%<br>50% 60% 70% 80% 90% 100%<br>LOAD<br>THD<br>**----- End of picture text -----**<br> ## **EFFICIENCY vs LOAD** ELG-200 series possess superior working efficiency that up to 93% can be reached in field applications. ※ 48V Model, Tcase at 80℃ **==> picture [249 x 122] intentionally omitted <==** **----- Start of picture text -----**<br> 96<br>94<br>92<br>90 277V(200W)<br>88 230V(200W)<br>86 115V(150W)<br>84<br>82<br>80<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> **==> picture [20 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> LOAD<br>**----- End of picture text -----**<br> _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** ## **LIFE TIME** **==> picture [383 x 216] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>20 30 40 50 60 70 80 90<br>Tcase (℃ )<br>LIFETIME(Kh)<br>**----- End of picture text -----**<br> _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** ## **MECHANICAL SPECIFICATION** **==> picture [468 x 489] intentionally omitted <==** **----- Start of picture text -----**<br> ※ Blank-Type (for 12V model) CASE NO.: 262A Unit:mm<br>244<br>233<br>300±20 220 300±20<br>ACL(Brown)ACN(Blue) tc 90 Vo+(Red)Vo-(Black)<br>SJOW 17AWGx2C SJTW 14AWGx2C<br>&H05RN-F 1.0mm2<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>※ Blank-Type (for other models)<br>244<br>233<br>300±20 220 300±20<br>ACL(Brown)ACN(Blue) tc 90 Vo+(Red)Vo-(Black)<br>&H05RN-F 1.0mmSJOW 17AWGx2C2 SJOW 17AWGx2C &05RN-F 1.0mm2<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>71 53.8<br>32<br>37 37.5<br>71 53.8<br>32<br>37 37.5<br>**----- End of picture text -----**<br> _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ A-Type (for 12V model)<br>244<br>233<br>300±20 220 300±20<br>ACL(Brown)ACN(Blue) tc 90 Vo+(Red)Vo-(Black)<br>SJOW 17AWGx2C SJTW 14AWGx2C<br>&H05RN-F 1.0mm2<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>14.5 38.5<br>※ A-Type (for other models)<br>244<br>233<br>300±20 220 300±20<br>ACL(Brown)ACN(Blue) tc 90 Vo+(Red)Vo-(Black)<br>SJOW 17AWGx2C 2<br>&H05RN-F 1.0mm2 SJOW 17AWGx2C &05RN-F 1.0mm<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>14.5 38.5<br>71 53.8<br>32<br>37 37.5<br>21.01<br>71 53.8<br>32<br>37 37.5<br>21.01<br>**----- End of picture text -----**<br> _File Name:ELG-200-SPEC 2018-09-30_ ## 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ AB-Type (for 12V model)<br>244<br>233<br>300±20 220 300±20<br>SJTW 14AWGx2C Vo-(Black)<br>ACL(Brown)ACN(Blue) tc 90 DIM+(Vo+(Red)Blue)<br>SJOW 17AWGx2C DIM-(White)<br>&H05RN-F 1.0mm2 UL2517 20AWGx2C<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>14.5 38.5<br>※ AB-Type (for other models)<br>244<br>233<br>300±20 220 300±20<br>SJOW 17AWGx2C<br>&05RN-F 1.0mm2 Vo-(Black)<br>ACL(Brown)ACN(Blue) tc 90 DIM+(Vo+(Red)Blue)<br>&H05RN-F 1.0mmSJOW 17AWGx2C2 UL2517 20AWGx2C DIM-(White)<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>14.5 38.5<br>71 53.8<br>32<br>37 37.5<br>21.01<br>71 53.8<br>32<br>37 37.5<br>21.01<br>**----- End of picture text -----**<br> _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ B/DA/D2-Type (for 12V model)<br>244<br>233<br>300±20 220 300±20<br>SJTW 14AWGx2C Vo-(Black)<br>ACL(Brown)ACN(Blue) tc 90 DIM+(Vo+(Red)Blue)*<br>SJOW 17AWGx2C DIM-(White)**<br>&H05RN-F 1.0mm2 UL2517 20AWGx2C<br>4-ψ4.5 * DIM+ for B-Type<br>DA+ for DA-Type<br>�tc : Max. Case Temperature * *DIM- for B-TypePROG+ for D2-Type<br>DA- for DA-Type<br>PROG- for D2-Type<br>※ B/DA/D2-Type (for other models)<br>244<br>233<br>300±20 220 300±20<br>SJOW 17AWGx2C<br>&05RN-F 1.0mm2 Vo-(Black)<br>ACL(Brown)ACN(Blue) tc 90 DIM+(Vo+(Red)Blue)*<br>&H05RN-F 1.0mmSJOW 17AWGx2C2 UL2517 20AWGx2C DIM-(White)**<br>4-ψ4.5 * DIM+ for B-Type<br>DA+ for DA-Type<br>�tc : Max. Case Temperature * *DIM- for B-TypePROG+ for D2-Type<br>DA- for DA-Type<br>PROG- for D2-Type<br>71 53.8<br>32<br>37 37.5<br>71 53.8<br>32<br>37 37.5<br>**----- End of picture text -----**<br> _File Name:ELG-200-SPEC 2018-09-30_ > 144~200W Constant Voltage + Constant Current LED Driver **ELG - 200 series** **==> picture [394 x 195] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 3Y Model (3-wire input)<br>244<br>233<br>300±20 220<br>AC/N(Blue)<br>AC/L(Brown) tc 90<br>PE (Green/Yellow) &H05RN-F 1.0mmSJOW 17AWGx3C2 SJOW 17AWGx2C&05RN-F 1.0mm2<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>◎ Note1: Please connect the case to PE for the complete EMC deliverance and safety use.<br>◎ Note2: Please contact MEAN WELL for input wiring option with PE.<br>71 53.8<br>32<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** Please refer to : http://www.meanwell.com/manual.html _File Name:ELG-200-SPEC 2018-09-30_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →