Image not available
Illustrative purposes only
EL-USB-3
Data Logger, 0 to 30V DC Measurement Range, Voltage, 1 Channel, 32510 Samples, USB, LED Indicator
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:USB Voltage; No. of Channels:1Channels; Reading Capacity:32510; Product Range:EasyLog; SVHC:No SVHC (15-Jan-2019); External Depth:27mm; External Length / Height:112mm; Ext
- SVHC: No SVHC (07-Nov-2024)
- Display Type: LED Indicator
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 32510 Samples
- Data Logger Type: Voltage
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 58.62 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **EL-USB-3** Voltage Data Logger - 0 to 30V d.c. measurement range - Stores over 32,000 readings - Logging rates between 1 second and 12 hours - Connection via two screw terminals - Immediate and delayed logging start - User-programmable alarm thresholds - Status indication via red and green LEDs - EasyLog software available as a free download This standalone data logger measures and stores over 32,000 voltage readings over a 0 to 30V d.c. range at a resolution of 50mV d.c. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the available free downloadable EasyLog software. Data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a lithium metal battery, which gives three year’s logging life. The data logger is also issued with a 0 to 30V d.c. cap and features a pair of screw terminals, a set of equitable measurement leads and then followed up with a set of durable crocodile clips. ## EASYLOG SOFTWARE Lascar’s EasyLog control software is available as a free download from www.easylogusb.com. Easy to install and use, the control software is compatible with 32-bit and 64-bit versions of Windows XP, Vista, 7 & 8. The software is used to set up the logger, download, graph and annotate data or export in Excel, PDF and jpeg formats. The software allows the following parameters to be configured: - Logger name - Logging rate (customisable between 1 second and 12 hours) - High and low alarms • Immediate and delayed logging start ~~ee~~ **Download the latest version of the software free of charge from www.lascarelectronics.com/software/easylog-usb** SPECIFICATIONS ## ACCESSORIES **==> picture [292 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Measurement range|0 to 30 V d.c.| |Internal resolution|50 mV d.c.| |Accuracy (overall error)|±1%| |Logging rate|User selectable between 1 second & 12 hours| |Operating temperature range|-35 to +80°C (-31 to +176°F)| |Battery Life|3 Years| |Readings|32,510| |Dimensions|98 x 26.8 x 26.8 mm| **----- End of picture text -----**<br> **==> picture [177 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |BAT 3V6 1/2AA|Replacement battery| |USB-CAP-30V|Replacement Cap,| |0 to 30V d.c. range| **----- End of picture text -----**<br> ## INCLUDED IN THE BOX **==> picture [182 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |BAT 3V6 1/2AA|Battery| |USB-CAP-30V|0 to 30V d.c. Range Cap| |EL-USB-LEADS|Measurement Leads| |EL-USB WALL BRACKET|Mounting Bracket| **----- End of picture text -----**<br> **www.lascarelectronics.com/data-loggers** Issue 18 02/2021 Page 1 of 3 ## **EL-USB-3** Voltage Data Logger ## LED STATUS INDICATION The EL-USB-3 features two LEDs: a green/red LED to indicate logging and alarm status. In normal operation the green LED will flash, but will change to red if an alarm condition has been triggered. Using EasyLog software it is possible to set the alarm to remain active even if the reading has returned to normal, in which case the alarm LED will continue to flash red. This ‘Hold’ feature in the software ensures the user is notified that at some point an alarm level has been exceeded, without needing to download the data. **Green single flash** _(Every 10 Seconds)_ ~~OO~~ The data logger is currently logging, no alarm. **Green single flash** _(Every 20 Seconds)_ ~~OO~~ The data logger is currently logging. No alarm. Although, battery is low and should be replaced before logging important data. **Green single flash** _(Every 30 Seconds)_ The data logger is not currenty logging, but is primed to start at a later date and time. _(Delayed start)_ ly **Green double flash** _(Every 20 Seconds)_ The data logger is full and has stopped logging, no alarm. ~~OO~~ **Red single flash** _(Every 10 Seconds)_ The data logger is currently logging. Low alarm. ~~[2~~ **Red single flash** _(Every 20 Seconds)_ The data logger is currently logging. Low alarm. Although, battery is low and should be replaced before logging important data. ~~OO~~ **Red double flash** _(Every 10 Seconds)_ The data logger is currently logging. High alarm. ~~OO~~ **Red double flash** _(Every 20 Seconds)_ The data logger is currently logging. High alarm. Although, battery is low and should be replaced before logging important data. ~~OO~~ **Red & green single flash** _(Every 20 Seconds)_ The data logger is full and has stopped logging. High, Low or both alarms. ~~CO~~ **No LEDs flash** The data logger is stopped, the battery is empty or there is no battery. ## CONNECTION & APPLICATIONS **==> picture [76 x 63] intentionally omitted <==** **----- Start of picture text -----**<br> Battery<br>+ _<br>**----- End of picture text -----**<br> **==> picture [106 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> +ve supply to sensor<br>Signal out<br>Sensor<br>-ve/GND supply to sensor<br>+ _<br>**----- End of picture text -----**<br> _Logging a battery voltage_ _Logging a sensor voltage_ **www.lascarelectronics.com/data-loggers** Issue 18 02/2021 Page 2 of 3 ## **EL-USB-3** Voltage Data Logger ## BATTERY INFORMATION ## **Replacement** We recommend that you replace the battery annually, or prior to logging critical data. Only use 3.6V ½AA lithium metal batteries. The data logger does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and will not resume until the battery is replaced and the logger restarted by EasyLog software. Before replacing the battery, remove the data logger from the PC. Please note that leaving the data logger plugged into the USB port for extended periods will cause some of the battery capacity to be lost. ## **Passivation** If left unused for extended periods of time, the lithium metal batteries used in the EasyLog range of data loggers naturally form a non-conductive internal layer, preventing them from self-discharge and effectively increasing their shelf life. When first installed in the data logger, this may cause a momentary drop in the battery voltage (the Transient Minimum Voltage) as the internal layer is broken down, resulting in the data logger resetting. Inserting the batteries in the data logger and leaving it connected to a PC for about 30 seconds will remove this layer. After this, remove and re-install the batteries to reset the data logger. Overall battery life will not be affected. ## WARNING Handle lithium metal batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. **www.lascarelectronics.com/data-loggers** Issue 18 02/2021 Page 3 of 3
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →