Image not available
Illustrative purposes only
EL-USB-2-LCD+
Data Logger, -35°C to 80°C Temp Range, 0 to 100%RH, Temperature, Humidity & Dew Point, 1 Channel
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:USB Temperature & Humidity; No. of Channels:2Channels; Reading Capacity:16379; Product Range:EasyLog; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (07-Nov-2024)
- Display Type: LCD
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 16382 Samples
- Data Logger Type: Temperature, Humidity & Dew Point
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 96.74 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **EL-USB-2-LCD+** High Accuracy Temperature, Humidity and Dew Point Data Logger with LCD Screen ▪ -35 to +80°C (-31 to +176°F) and 0 to 100%RH measurement range - Stores over 16,000 readings for both temperature and humidity - EasyLog software available as a free download - High contrast LCD, with two and a half digit temperature and humidity display function - Logging rates between 10 seconds and 12 hours - Immediate, delayed and push-to-start logging - User-programmable alarm thresholds for both temperature and humidity - Status indication via red/green LEDs - Environmental protection to IP67 This standalone data logger measures and stores over 16,000 temperature and humidity readings from -35 to +80°C (-31 to +176°F) and 0 to 100%RH range at a resolution of 0.5°C (1°F) and 0.5%RH. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the free EasyLog software. Data, including calculated dew point, can then be graphed, printed and exported to other applications for detailed analysis. The high contrast LCD can show a variety of temperature and humidity information. At the touch of a button, the user can cycle between the current temperature and humidity, along with the maximum and minimum stored values for temperature and humidity. **==> picture [527 x 438] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |The data logger is supplied with a lithium metal battery, giving up to 2 years’ logging life. The logger is protected against ingress from| |water and dust to IP67 standard when the cap is fitted.| |SPECIFICATIONS|ACCESSORIES| |Temperature|Measurement range|-35°C to 80°C (-31°F to 176°F)| |BAT 3V6 1/2AA|Replacement battery| |Internal resolution|0.5°C (1°F)| |Accuracy (overall error)*|0.45°C (0.86°F) typical (5 to 60°C)|INCLUDED IN THE BOX| |Long term stability|<0.02°C (0.04°F) / year| |Relative Humidity|Measurement range|0 to 100%RH|BAT 3V6 1/2AA|Battery| |Internal resolution|0.5%RH|EL-LCD WALL BRACKET|Mounting Bracket| |Accuracy (overall error)*|2.05%RH typical (10 to 90%RH)| |Long term stability|<0.25%RH / year| |Dew Point|Accuracy (overall error)*|1.5°C typical| |(-35 to 80°C, 40 to 100%RH)| |Logging rate|User selectable between 10| |seconds & 12 hours| |Operating temperature range|-35 to +80°C (-31 to +176°F)| |Battery life|2 years (at 25°C and 1 minute| |logging rate)| |Readings|16,382 temperature,| |16,382 relative humidity| |Dimensions|126 x 25 x 22mm| |(4.96 x 0.98 x 0.86”)| |=_| |* The overall error takes in to account the sensor accuracy (as shown on page 4) and the| |resolution of the data logger| |CALIBRATION CERTIFICATES NOW AVAILABLE| |Lascar now offers a Traceable Calibration Certificate Service on Temperature Data Loggers. Using reference equipment| |which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or|www.lascarelectronics.com/data-loggers|GS| |international standards. For more information, please see|www.lascarelectronics.com|.| |Issue 12 04/2024 Page 1 of 5| |Kes| **----- End of picture text -----**<br> ## **EL-USB-2-LCD+** High Accuracy Temperature, Humidity and Dew Point Data Logger with LCD Screen ## EASYLOG SOFTWARE Lascar’s EasyLog control software is available as a free download from www.easylogusb.com. Easy to install and use, the control software is compatible with 32-bit and 64-bit versions of Windows 7, 8 & 10. The software is used to set up the logger, download, graph and annotate data or export in Excel, PDF and jpeg formats. The software allows the following parameters to be configured: - Logger name - Measurement parameter (°C or °F) - Logging rate (user selectable between 10 seconds and 12 hours) - High and low alarms ▪ Immediate and delayed logging start - **Download the latest version of the software free of charge from www.easylogusb.com** - ~~LL~~ ## DISPLAY STATUS INDICATION The EL-USB-2-LCD+ features a high contrast LCD which shows logged temperature and humidity values using seven segment numbes, along with annunciators. The LCD can also show information regarding the loging status. The LCD shows six different recorded readings, which can be cycled through using the built-in push button. The most recent logged value, maximum logged value and minimum logged value can be displayed separately for humidity and temperature. **==> picture [217 x 131] intentionally omitted <==** **----- Start of picture text -----**<br> Maximum logged Relative Humidity<br>value symbol symbol<br>| |<br>Negative symbol _ AITIT %RH<br>VILILIS°C°F<br>| | |<br>Minimum logged Reading Temperature<br>value symbol scale<br>**----- End of picture text -----**<br> |~~a~~||| |---|---|---| |**Display**<br>~~a~~|**Logger Status**|**Explanation**| |~~a~~<br>~~ee~~|Delayed Start<br>~~ee~~|This is shown when the logger is set to start at a specific date and time. If the logger is set to ‘LCD off’ or<br>‘LCD on for 30 seconds’ mode, then this will only be shown after the button is pressed. Otherwise the<br>display will remain blank| |~~ee~~|Push to Start<br>~~ee~~|This is shown when the logger is setup for ‘Push to Start’ logging| |~~ee~~|Logging<br>~~ee~~|This is shown when the logger is running in ‘LCD off’ mode, and the button is pressed. The display clears<br>again after three seconds| |~~ee~~|Stopped<br>~~ee~~|If the logger has not been set to log and the button is pressed, three dashes are displayed for three<br>seconds| **www.lascarelectronics.com/data-loggers** Issue 12 04/2024 Page 2 of 5 ## **EL-USB-2-LCD+** High Accuracy Temperature, Humidity and Dew Point Data Logger with LCD Screen ## LED STATUS INDICATION The EL-USB-2-LCD+ features two green/red LEDs, one to represent temperature measurement and the other to represent humidity measurement. Each is clearly marked on the logger. To save power, the status indication alternates between the two channels every 10 seconds. First you will see the status of the temperature channel and 10 seconds later you will see the status of the RH channel and so on. 10 seconds later **RH% °C (°F) RH% °C (°F)** In normal operation the green LED will flash, but will change to red if an alarm condition has been triggered. Using EasyLog software it is possible to set the alarm to remain active even if the reading has returned to normal, in which case the alarm LED will continue to flash red. This ‘Hold’ feature in the software ensures the user is notified that at some point an alarm level has been exceeded, without needing to download the data. |1,~~OO~~|**Green double flash**<br>The data logger is not currently logging, but is primed to start at a later date and time (delayed start)<br>~~OO~~| |---|---| |~~OO~~<br>~~1~~<br>~~Fe~~|**Green single flash**<br>The data logger is currently logging. No alarm on the channel<br>~~OO~~<br>| |~~Fe~~|**Red single flash**<br>The data logger is currently logging. Low alarm on the channel<br>| |~~FeOS~~|**Red double flash**<br>The data logger is currently logging. High alarm on the channel<br>~~OS~~| |~~OS~~<br>~~CO~~<br>~~Fe~~|**Green triple flash**<br>The data logger is full and has stopped logging. No alarm on the channel<br>~~OS~~<br>~~CO~~| |~~Fe~~|**Red triple flash**<br>The data logger is full and has stopped logging. Alarm (high, low or both) on the channel| |~~Fe~~<br>~~OO~~|**No LEDs flash**<br>The data logger is stopped, the battery is empty or there is no battery<br>~~OO~~| |~~OO~~|**Dual Red flash (every 60 seconds)**<br>The data logger battery is running low as it’s voltage has dropped below 2.9V<br>~~OO~~| **www.lascarelectronics.com/data-loggers** Issue 12 04/2024 Page 3 of 5 ## **EL-USB-2-LCD+** ## High Accuracy Temperature, Humidity and Dew Point Data Logger with LCD Screen ## SENSOR ACCURACY & INFORMATION Typical and maximal tolerance for temperature sensor in °C. Typical and maximal tolerance at 25°C for relative humidity. **==> picture [153 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> ΔT (°C)<br>± 2.0<br>maximum accuracy<br>± 1.5 typical accuracy<br>± 1.0<br>± 0.5<br>± 0.0<br>-40 -20 0 20 40 60 80<br>Temperature (°C)<br>**----- End of picture text -----**<br> **==> picture [198 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> Δ RH (%RH)<br>± 10<br>maximum accuracy<br>± 8 typical accuracy<br>± 6<br>± 4<br>± 2<br>± 0<br>0 10 20 30 40 50 60 70 80 90 100<br>Relative H umidity (%RH)<br>**----- End of picture text -----**<br> Typical accuracy of r ~~elatve humidity measurements given in~~ %RH f ~~or temperatures 0 to 80°C.~~ **==> picture [186 x 150] intentionally omitted <==** **----- Start of picture text -----**<br> 100 ±3 ±2.5 ±3 ±3.5<br>90 ±2 ±2.5 ±3<br>80 ±2.5 ±3<br>70 ±2.5 ±2 ±2.5<br>60<br>50 ±2 ±1.8<br>40<br>30<br>2 0<br>10 ±2.5 ±2<br>0 ±3 ±2.5<br>0 10 20 30 40 50 60 70 80<br>Temperature (°C)<br>)H<br>R<br>%<br>( ytidi<br>m<br>u<br>H<br> e<br>vitale<br>R<br>**----- End of picture text -----**<br> Operating conditions **==> picture [213 x 182] intentionally omitted <==** **----- Start of picture text -----**<br> 100 PTT Ty yy TPT Ty TTT<br>80 We}ht |] yy yyyyy<br>60 ni tt Ty |AN<br>rit itVT |tT Py | | Normal |PtPre yy Max. Py yt<br>40 pt Range PR Range<br>res IV}TVE T f}TT]ft || dy| rdtTrT PNAT IN I<br>20 PIS}; XP PytN<br>CORSET<br>0 i i eee ee<br>-40 -20 0 20 40 60 80 100 120<br>Temperature (°C)<br>Long term exposure to humidity levels outside of the<br>‘normal’ range may temporarily offset RH measurements<br>(±3%RH after 60 hours). Once returned to less extreme<br>conditions the device will slowly return towards calibration<br>state.<br>Relative Humidity (%)<br>**----- End of picture text -----**<br> When tracking changes in ambient conditions, the response time of the humidity sensor in your data logger is approximately 20 minutes to reach 90% of the reading. However, if you are measuring step changes in humidity (for example if calibrating the product) it is advised that you leave the unit for up to four hours to ensure that it has enough time to settle at the new level. It is worth remembering that the value of relative humidity is of course sensitive to temperature variation. As an example, at a relative humidity of ~90%RH at ambient temperature, a variation in temperature of 1°C will result in a change of up to -5%RH. Therefore when comparing multiple devices or calibrating them, any temperature variations must be considered. **www.lascarelectronics.com/data-loggers** Issue 12 04/2024 Page 4 of 5 ## **EL-USB-2-LCD+** ## High Accuracy Temperature, Humidity and Dew Point Data Logger with LCD Screen ## SENSOR ACCURACY & INFORMATION The humidity measuring element in the humidity data loggers can be contaminated through exposure to a variety of compounds. These products should not be kept in proximity to volatile chemicals such as solvents and other organic compounds. Generally speaking, if a material or compound emits a strong odour you should not keep your humidity data logger in close proximity to it. If you would like more information, please contact your local Lascar Electronics office. Exposure to extreme conditions or chemical vapours will require the following reconditioning procedure to bring the internal sensor back to calibration state: _**Baking**_ 80°C (176°F) at < 5%RH for 36 hours. _**Re-hydration**_ 20 to 30°C (70 to 90°F) at > 74%RH for 48 hours. High levels of pollutants may cause permanent damage to the internal sensor. ## BATTERY INFORMATION ## **Replacement** We recommend that you replace the battery annually, or prior to logging critical data. Only use 3.6V ½AA lithium metal batteries. The data logger does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and will not resume until the battery is replaced and the logger restarted by EasyLog software. Before replacing the battery, remove the data logger from the PC. Please note that leaving the data logger plugged into the USB port for extended periods will cause some of the battery capacity to be lost. ## **Passivation** If left unused for extended periods of time the lithium metal batteries, including those used in the EasyLog range of data loggers, naturally form a non-conductive internal layer preventing them from self-discharge and effectively increasing their shelf life. When first installed in the data logger, this may cause a momentary drop in the battery voltage (the Transient Minimum Voltage) as the internal layer is broken down, resulting in the data logger resetting. Inserting the batteries in the data logger and leaving it connected to a PC for about 30 seconds will remove this layer. After this, remove and re-install the batteries to reset the data logger. Overall battery life will not be affected. ## WARNING Handle lithium metal batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. **www.lascarelectronics.com/data-loggers** Issue 12 04/2024 Page 5 of 5
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →