Image not available
Illustrative purposes only
EL-USB-1-RCG
Data Logger, -20 to 60°C Temperature Range, Temperature, 1 Channel, 32510 Samples, USB
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:USB Temperature; No. of Channels:1Channels; Reading Capacity:32510; Product Range:EL-USB Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (07-Nov-2024)
- Display Type: LED Indicator
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 32510 Samples
- Data Logger Type: Temperature
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 113.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
Temperature Data Logger with Rechargeable Battery ## **EL-USB-1-RCG** - -20 to +60°C (-4 to +140°F) measurement range - Stores over 32,000 readings - EasyLog software available as a free download - Stainless steel (316 grade) case - Rechargeable Lithium-Ion battery - Logging rates between 1 second and 12 hours - Immediate and delayed logging start - User-programmable alarm thresholds - Red & green status LEDs behind protective glass window - Environmental protection to IP67 - Supplied with Type A-Mini B USB cable This standalone data logger measures and stores more than 32,000 temperature readings over a -20 to +60°C (-4 to +140°F) range with a resolution of 0.1°C (0.2°F). The polycarbonate window and stainless steel 316 assembly provides protection from corrosion, impact and water ingress to IP67/NEMA 4X. The user can easily set up the logger and view downloaded data by connecting the data logger to a PC’s USB port and using the free EasyLog software. Data can then be graphed, printed and exported to other applications for detailed analysis. The data logger is powered by a Lithium-Ion battery which can typically allow for logging for up to 1 month. ## SPECIFICATIONS ## INCLUDED IN THE BOX **==> picture [292 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Measurement range|-20 to +60°C (-4 to +140°F)| |Internal resolution|0.1°C (0.2°F)| |Accuracy (overall error)|±1°C (±2°F)| |Logging rate|User selectable between 1 second & 12 hours| |Operating temperature range|-20 to +60°C (-4 to +140°F)| |Battery Life|4 weeks (at 20°C and 1 minute logging rate)| |Recharging time|5 hours| |Charging temperature range|+10 to +30°C (+50 to +86°F)| |Readings|32,510| |Dimensions|93 x 20mm (3.66 x 0.78”)| **----- End of picture text -----**<br> **CABLE USB A-MF** Type A - Mini B USB Cable ## CALIBRATION CERTIFICATES NOW AVAILABLE Lascar now offers a Traceable Calibration Certificate Service on Temperature Data Loggers. Using reference equipment which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or international standards. For more information, please see **www.lascarelectronics.com** . ## **EL-USB-1-RCG** ## Temperature Data Logger with Rechargeable Battery ## LED STATUS INDICATION EL-USB-1-RCG features two LEDs: - The first LED flashes **red** to indicate that the EL-USB-1-RCG is in an alarm condition. It will flash when the logged temperature has exceeded a Low or High alarm level. - The second LED flashes **green** to indicate that the EL-USB-1-RCG is not in an alarm condition. Using EL-WIN-USB it is possible to set the alarm to remain active even if the reading has returned to normal, in which case the alarm LED will continue to flash red. This ‘Hold’ feature in the software ensures the user is notified that at some point an alarm level has been exceeded, without needing to download the data. Hold is enabled by default, and can be turned off via the control software. The red LED will then only flash whilst the logger is in an alarm condition. When the temperature returns to normal, the green LED will flash. |~~0~~|**Green single flash (every 30 seconds)**<br>The data logger is not currently logging, but is primed to start at a later date and time (delayed start)| |---|---| |~~0~~<br>~~0~~|**Green single flash (every 10 seconds)**<br>The data logger is currently logging. No alarm<br>| |~~0OS~~<br>~~OS~~|**Red single flash (every 10 seconds)**<br>The data logger is currently logging. Low alarm<br>~~OS~~<br>~~OS~~| |~~OS~~<br>~~OS~~|**Red double flash (every 10 seconds)**<br>The data logger is currently logging. High alarm<br>~~OS~~<br>~~OS~~| |~~OS~~<br>~~0~~<br>~~oe~~|**Green single flash (every 20 seconds)**<br>The data logger is currently logging. Low battery<br>~~OS~~| |~~0~~<br>~~oe~~<br>~~oe~~|**Red single flash (every 20 seconds)**<br>The data logger is currently logging, however the battery is running low. Low alarm<br>| |~~oe~~<br>~~oeOO~~|**Red double flash (every 20 seconds)**<br>The data logger is currently logging, however the battery is running low. High alarm<br>~~OO~~| |~~oeOO~~|**Green double flash (every 20 seconds)**<br>The data logger is full and has stopped logging<br>~~OO~~| |~~OO1~~<br>~~00~~|**Red & Green single flash alternately (every 20 seconds)**<br>The data logger is full and has stopped logging. High or low alarm<br>~~OO1~~<br>~~00~~| |~~1~~<br>~~00~~|**No LEDs flash**<br>The data logger is stopped, the battery is empty or there is no battery<br>~~1~~<br>~~00~~| **www.lascarelectronics.com/data-loggers** Issue 7 02/2021 Page 2 of 3 ## **EL-USB-1-RCG** ## Temperature Data Logger with Rechargeable Battery ## EASYLOG SOFTWARE Lascar’s EasyLog control software is available as a free download from www.easylogusb.com. Easy to install and use, the control software is compatible with 32-bit and 64-bit versions of Windows 7, 8 & 10. The software is used to set up the logger, download, graph and annotate data or export in Excel, PDF and jpeg formats. The software allows the following parameters to be configured: ▪ Logger name ▪ Measurement parameter (°C or °F) ▪ Logging rate (user selectable between 1 second and 12 hours) ▪ High and low alarms ▪ Immediate and delayed logging start **Download the latest version of the software free of charge from www.easylogusb.com** ## BATTERY INFORMATION The EL-USB-1-RCG is fitted with a 280mAh capacity (nominal) rechargeable Lithium-Ion battery. The logger must be connected to an active USB port to recharge the battery; this may take up to 5 hours, depending on the level of discharge. The battery charge status is indicated by the status LEDs. The red LED indicates that charging is ongoing; the green LED indicates that the battery is fully charged. The fully charged capacity of the rechargeable battery will reduce over time. The battery operates best at temperatures of +10 to +30°C (+50 to +86°F). Recharging should only be performed within this temperature range. **www.lascarelectronics.com/data-loggers** Issue 7 02/2021 Page 3 of 3
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →