Image not available
Illustrative purposes only
EL-OEM-3
Data Logger, 0 to 24V DC Measurement Range, Voltage, 1 Channel, 64K Samples, USB
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:Voltage; No. of Channels:1Channels; Reading Capacity:64000; Product Range:EasyLog; SVHC:No SVHC (15-Jan-2019); Input Voltage:3.6V DC
- SVHC: No SVHC (07-Nov-2024)
- Display Type: -
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 64K Samples
- Data Logger Type: Voltage
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 31.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **EL-OEM-3** ## OEM Packaged Voltage Data Logger ## FEATURES - PCB Mounted (2.54mm pitch, header sockets) - 0 to 2.4V d.c. Measurement Range - Logging Rates between 1s and 12hr - Stores 64,000 readings - USB interface for set-up and data download (USB connector not included on module. Module not designed to be permanently connected to USB) - User-programmable alarm thresholds - EasyLog software available as a free download This component style data logger measures and stores up to 64,000 voltage readings over a 0 to 2.4V d.c. measurement range. It can be incorporated into new and existing products without the need to specifically develop a hardware and software platform. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the available free downloadable EasyLog software. Data can then be graphed, printed and exported to other applications. ## SPECIFICATIONS **==> picture [292 x 101] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Measurement range|0 to 2.4V d.c.| |Internal resolution|2.4mV| |Accuracy (overall error)|±1%| |Logging rate|User selectable between 1 second & 12 hours| |Supply voltage|2.75 to 3.6V| |Operating current|0.01 to 3mA| |Operating temperature range|-40 to 85°C (-40 to 185°F)| **----- End of picture text -----**<br> ## ACCESSORIES **EL-OEM-TEST** www.lascarelectronics.com Issue 16 07/2016 N.R Page 1 of 5 ## **EL-OEM-3** OEM Packaged Voltage Data Logger ## EL-WIN-USB Lascar’s EasyLog control software is available as a free download from www.easylogusb.com. Easy to install and use, the control software is compatible with 32-bit and 64-bit versions of Windows 7, 8 and 10. The software is used to set up the logger, download, graph and annotate data or export in Excel, PDF and jpeg formats. The software allows the following parameters to be configured: ▪ Logger name ▪ Logging rate (customisable between 1 second and 12 hours) ▪ High and low alarms ▪ Immediate and delayed logging start **Download the latest version of the software free of charge from www.easylogusb.com** ## APPLICATION NOTES AND PIN FUNCTIONS 1. USB +5 +5V rail for USB interface 2. USB D+ Positive data line for USB interface 3. USB D- Negative data line for USB interface 4. USB 0V Ground rail for USB interface 5. 0V Module ground 6. ALM1 Logging status* 7. ALM2 Logging status* 8. VIN 0 – 2.4V d.c. signal input 9. N.C. Not Connected - do not connect to this pin 10. V+ Supply voltage input, suitable for voltages between 2.75V and 3.6V - *See the alarm section www.lascarelectronics.com Issue 16 07/2016 N.R Page 2 of 5 ## **EL-OEM-3** OEM Packaged Voltage Data Logger ## POWER SUPPLY OPTIONS The logger is suitable for voltages between 2.75V and 3.6V. This can either be from a battery or using an external voltage regulator. If the voltage drops below 2.75V, the logger will reset to a stopped condition (i.e. in the event of a depleted battery). ## ALARM/INDICATOR OUTPUT Maximum output current 10mA. ALM1 shows logging status when the hardware isn’t in an alarm condition. ALM2 shows logging status when the hardware is in an alarm condition. www.lascarelectronics.com Issue 16 07/2016 N.R Page 3 of 5 ## **EL-OEM-3** OEM Packaged Voltage Data Logger ## VOLTAGE INPUT D.C. voltages of less than 2.4V can be measured using VIN directly. Voltages greater than 2.4V require rescaling, as per the table below: **==> picture [248 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> Required F.S.R. Ra Rb<br>5V 36K 30k<br>10V 51K 15k<br>30V 56K 4K7<br>————<br>Vsig can be connected to the positive supply rail and used to record the<br>supply voltage.<br>**----- End of picture text -----**<br> ## DIMENSIONS All dimensions in mm (inches) **==> picture [40 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 12.48 (0.49)<br>**----- End of picture text -----**<br> **==> picture [128 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> 2.5 max (0.1)<br>1.6 nom (0.06)<br>2.54 nom (0.1)<br>5.84 nom (0.23)<br>1.68 (0.06)<br>**----- End of picture text -----**<br> **==> picture [342 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> 6.87 (0.27)<br>2.54 (0.1)<br>19.0 (0.74) 15.24 (0.6)<br>24.0 (0.94)<br>**----- End of picture text -----**<br> www.lascarelectronics.com Issue 16 07/2016 N.R Page 4 of 5 ## **EL-OEM-3** ## OEM Packaged Voltage Data Logger ## ALARM OUTPUT MODES EL-OEM-3 features a two alarm outputs - ALM 1 and ALM 2. By default hold is disabled. In this mode the ALM 1 will no longer continue to pulse after the logged reading has returned to normal from an alarm condition. Hold can be turned on via the control software. In this mode ALM 1, that indicates an alarm condition, will continue to pulse even after the logged reading has returned to normal. This feature ensures that the user is notified that an alarm level has been exceeded, without the need to download the data from the logger. |**ALM 1**<br>**ALM 1**<br>**ALM 1**<br>**ALM 1**<br>**ALM 1**|**ALM 2**<br>**ALM 2**<br>**ALM 2**<br>**ALM 2**<br>**ALM 2**|ALM 2 single pulse (10 seconds)<br>The data logger is currently logging. No alarm.| |---|---|---| |||ALM 2 single pulse (20 seconds)<br>The data logger is currently logging. No alarm. However, the batery is low and should be replaced before<br>logging important data.| |||ALM 2 single pulse (30 seconds)<br>The data logger is not currently logging, but is primed to start at a later date and tme (delayed start).| |||ALM 2 double pulse (20 seconds)<br>The data logger is full and has stopped logging. No alarm.| |||ALM 1 single pulse (10 seconds)<br>The data logger is currently logging. Low alarm.| |||ALM 1 single pulse (20 seconds)<br>The data logger is currently logging. Low alarm. However, the batery is low and should be replaced before logging<br>important data.| |||ALM 1 double pulse (10 seconds)<br>The data logger is currently logging. High alarm.| |||ALM 1 double pulse (20 seconds)<br>The data logger is currently logging. High alarm. However, the batery is low and should be replaced before logging<br>important data.| |||ALM 1/ ALM 2 single pulse (20 seconds)<br>The data logger is full and has stopped logging. Alarm (high, low or both).| |||No pulse<br>The data logger is stopped, the batery is empty or there is no batery fted.| www.lascarelectronics.com Issue 16 07/2016 N.R Page 5 of 5
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →