Image not available
Illustrative purposes only
EL-MOTE-TH
Data Logger, WiFi Temperature & Humidity, 1 Channel, Humidity, Temperature, WiFi, LED
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:WiFi Temperature & Humidity; No. of Channels:1Channels; Reading Capacity:-; Product Range:EL-MOTE Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (14-Jun-2023)
- Display Type: LED
- Product Range: EL-MOTE Series
- Data Interface: WiFi
- Maximum Samples: -
- Data Logger Type: WiFi Temperature & Humidity
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: Humidity, Temperature
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 107.04 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **EL-MOTE-TH** Temperature & Humidity Cloud-Connected Data Logger - Measures ambient temperature between -30 to +80 °C/-22 to +176 °F and relative humidity 0 to 100 %RH - Records and uploads temperature and humidity data to the EasyLog Cloud - Access live temperature and humidity data via any Internet Browser or the EasyLog Cloud App - Set up alarm options for temperature and humidity zone breaches - email alerts, beeper alarms or LED flash alerts - Suitable for indoor and outdoor use - Battery life of up to 2 years The EL-MOTE-TH kit has been designed to monitor air temperature and relative humidity in a large range of applications. Its external temperature and humidity probe made it an ideal choice for applications where it may be problematic to locate the whole device such as museum display cases and HVAC systems. Products in the EL-MOTE range are simple to set-up and easy to use. Download the EasyLog Cloud App and set-up a device in minutes over your WiFi network. After set-up, the device can be placed anywhere within range of the WiFi network, continually monitoring and recording your data to the EasyLog Cloud. Access your data on any Internet Browser or the EasyLog Cloud App, enabling you to monitor the ambient temperature and humidity of your chosen location from anywhere at any time. EL-MOTE devices can be programmed with high and low temperature and humidity alarm zones. If a temperature or humidity zone is breached, an alarm will be activated. Alarm options include: email alerts (which can be sent to one or multiple email addresses), beeper sound alarms, and LED flash alerts. EL-MOTE devices can be powered using the supplied batteries or a mains adapter (sold separately), and are provided with a wall mountable bracket for installation. **www.lascarelectronics.com/data-loggers** Issue 4 03/2019 Page 1 of 3 ## **EL-MOTE-TH** Temperature & Humidity Cloud-Connected Data Logger |Logger Specification|Minimum|Typical|Maximum|Unit| |---|---|---|---|---| |**Battery Life**||2*||years| |**Battery Type**|4 x 1.5V AA cells|||| |**Operating Temperature (Powered by Batteries Supplied)**|-18 (-0.4)||+55 (+131)|˚C (˚F)| |**Operating Temperature (Mains Adapter Powered)**|-20 (-4)||+60 (+140)|˚C (˚F)| |**Logging Period (User Configurable)**|10 sec|10 min|12 hrs|| |**Transmission Period (User Configurable)**|1 min|1 hour|24 hours|| |**Dimensions**<br>~~a~~|93 x 93 x 32 (3.7 x 3.7 x 1.3)|||mm (inches)| |**IP Rating**<br>~~a~~|67|||| |Probe Specification|Minimum|Typical|Maximum|Unit| |---|---|---|---|---| |**Temperature Range**|-30 to +80 (-22 to +176)|||˚C (˚F)| |**Temperature Resolution**|0.1 (0.1)|||˚C (˚F)| |**Temperature Accuracy**||±0.3 (+5 to +60)<br>(±0.6 (+41 to +140))|±0.8 (-20 to +60)<br>(±1.6 (-4 to +140))|˚C (range)<br>(˚F (range))| |**Humidity Range**|0 to 100|||%RH| |**Humidity Resolution**<br>~~a~~|1|||%RH| |**Humidity Accuracy (@25˚C)**<br>~~a~~||±2** (20 to 80)|±5** (0 to 100)|%RH (%RH)<br>|| |**Probe Dimensions (Without Bracket)**<br>~~a~~|37 x 12 x 8 (1.5 x 0.5 x 0.3)|||mm (inches)| |**Cable Length**|2000 (79)|||mm (inches)| The sensor is IEEE 802.11bgn (2.4GHz) compliant, supports WEP, WPA/WPA2 encryption and enterprise networks (PEAP, TTLS, FAST). **211-140401 CONTAINS FCC ID:** FE Ce & **YOPGS2011MIZ** * Battery life is dependent on: transmission period, WiFi encryption method, WiFi encryption key rotation frequency (determined by the router/access point), signal strength between router/access point and WiFi device, presence, volume and type of WiFi traffic from other devices, sample rate and operating temperature. Logging period and transmission period can be configured in Settings via the EasyLog Cloud App. **Please refer to the charts in this datasheet for more detailed accuracy specifications. ## WHAT’S IN THE BOX? ## WHAT EXTRA ACCESSORIES ARE AVAILABLE? |PART NUMBER<br>DESCRIPTION|||PART NUMBER|DESCRIPTION| |---|---|---|---|---| |**EL-MOTE WALL BRACKET**<br>Wall Mounting Bracket for EL-MOTE Device<br>**BATTERIES**<br>1.5V AA x 4<br>**EL-SP-TH**<br>Temperature and Humidity Probe on 2m Cable<br>|<br>|<br>|<br>~~es~~<br>~~ee~~||**EL-MOTE-PSU**<br>Mains Power Adapter<br>**EL-SP-TH**<br>Temperature and Humidity Probe on 2m Cable<br>**EL-MOTE WALL BRACKET**<br>Wall Mounting Bracket for EL-MOTE Device<br>|<br>|||| Specifications liable to change without prior warning ## CALIBRATION CERTIFICATES NOW AVAILABLE EasyLog offers a Traceable Calibration Certificate Service on Temperature and Humidity Data Loggers using reference equipment which has been calibrated by a UKAS/NIST/HKAS or CNAS accredited laboratory and using apparatus traceable to national or international standards. For more information please see **www.lascarelectronics/calibration** Issue 4 03/2019 Page 2 of 3 ## **EL-MOTE-TH** Temperature & Humidity Cloud-Connected Data Logger **==> picture [39 x 53] intentionally omitted <==** ## SENSOR ACCURACY & INFORMATION Typical and maximal tolerance for temperature sensor in °C. **==> picture [163 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> ΔT (°C)<br>± 2.0<br> maximum error<br>± 1.5 typical accuracy<br>± 1.0<br>± 0.5<br>± 0.0<br>-40 -20 0 20 40 60 80<br>Temperature (°C)<br>**----- End of picture text -----**<br> Typical and maximal tolerance at 25°C for relative humidity. **==> picture [209 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> ΔRH (%RH)<br>± 10<br> maximum error<br>± 8 typical accuracy<br>± 6<br>± 4<br>± 2<br>± 0<br>0 10 20 30 40 50 60 70 80 90 100<br>Relative Humidity (%RH)<br>**----- End of picture text -----**<br> Typical accuracy of r ~~elatve humidity measurements given in~~ %RH for temperatur ~~es 0 to 80~~ ° ~~C.~~ **==> picture [196 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> 100 ±3.5 ±3 ±3.5 ±4<br>90 ±2.5 ±3 ±3.5<br>80 ±3 ±3.5<br>70 ±3 ±2.5 ±3<br>60<br>50 ±2.5 ±2<br>40<br>30<br>20<br>10 ±3 ±2.5<br>0 ±3.5 ±3<br>0 10 20 30 40 50 60 70 80<br>Temperature (°C)<br>Relative Humidity (%RH)<br>**----- End of picture text -----**<br> Operating conditions **==> picture [207 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>Normal Max.<br>40 Range Range<br>20<br>0<br>-40 -20 0 20 40 60 80 100 120<br>Temperature (°C)<br>Relative Humidity (%)<br>**----- End of picture text -----**<br> Long term exposure to humidity levels outside of the ‘normal’ range may temporarily offset RH measurements (±3%RH after 60 hours). Once returned to less extreme conditions the device will slowly return towards calibration state. When tracking changes in ambient conditions, the response time of the humidity sensor in your data logger is approximately 20 minutes to reach 90% of the reading. However, if you are measuring step changes in humidity (for example if calibrating the product) it is advised that you leave the unit for up to four hours to ensure that it has enough time to settle at the new level. It is worth remembering that the value of relative humidity is of course sensitive to temperature variation. As an example, at a relative humidity of ~90%RH at ambient temperature, a variation in temperature of 1°C will result in a change of up to -5%RH. Therefore when comparing multiple devices or calibrating them, any temperature variations must be considered. **www.lascarelectronics.com/data-loggers** Issue 4 03/2019 Page 3 of 3
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →