EL-IOT-CO2- PROMO
Data Logger, Promo, Carbon Dioxide, Temperature & Humidity, 1 Channel, 300K Samples, WiFi, LCD
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- Display Type: LCD
- Product Range: EasyLog Series
- Data Interface: WiFi
- Maximum Samples: 300K Samples
- Data Logger Type: Carbon Dioxide, Temperature & Humidity
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 147.83 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **EL-IOT-CO2** ## **Carbon Dioxide WiFi Cloud-Connected Data Logger** ## **Your data, anytime, anywhere** - **Monitor the air quality in homes, schools and offices** - **Measures:** - **Carbon dioxide ( CO2 )** - **Temperature** - **Humidity** - **Automatically uploads data to the EasyLog Cloud** - **Display shows current, maximum and minimum readings** - **Status indicators and sounder** - **Set up instant alarms and notifications** - **Readings are recorded even if the WiFi signal is lost** - **CO2 sensor automatically self-calibrates** The EL-IOT-CO2 continuously monitors air quality and comfort levels, including CO2, a key indicator of adequate ventilation. It automatically uploads data to the EasyLog Cloud, allowing your complete set of data measurements to be viewed, analysed and downloaded from any internet-enabled device. **==> picture [82 x 93] intentionally omitted <==** **----- Start of picture text -----**<br> a<br>Carbon Dioxide Temperature<br>Humidity<br>**----- End of picture text -----**<br> It takes only a few minutes to set up your EL-IOT-CO2, and you can configure your own high and low alarms for each measured parameter. If one of your set levels is breached an instant alarm is activated on the device, and notification options include email and SMS messages to your chosen contacts. The display shows current, maximum and minimum readings for carbon dioxide, temperature and humidity, as well as alarm and device status. The EL-IOT-CO2 runs from a USB power supply (supplied with the product) and can use AA batteries to provide a short-term backup if the power supply is interrupted. It is also provided with a wall mountable bracket for easy installation. **Continuously monitors air quality** **www.lascarelectronics.com** ## **EL-IOT-CO2** ## **Carbon Dioxide WiFi Cloud-Connected Data Logger** ## **Your data, anytime, anywhere** ## **EasyLog Cloud** ## **Your Data: Anytime. Anywhere.** Easily access your most important data, anywhere Automatic emails alerts and SMS Connect data loggers from multiple sites in one account Remotely manage all of your data logger devices Graph, review and analyse your data Audits are easy with our event log system Secure Cloud storage Configurable user profiles ## **EasyLog Cloud App** Available for Android and Apple devices, the EasyLog Cloud app enables you to monitor and manage your wireless sensors on the go. Access your vital data from any internet-enabled computer, tablet or mobile device with EasyLog Cloud. From single locations to worldwide operations, the system is perfectly scalable and can run through your existing wireless networks. Critical events are notified to specific users in seconds via an alarm system that’s easily tailored to your exact requirements. Data is accessible 24/7 and powerful online tools make it simpler than ever to view, compare and analyse readings. An audit trail is automatically created that includes both system and data events. Starter and Professional accounts are available, always flexible and with no locked-in contracts. If you choose not to connect your EL-IOT-CO2 to the Cloud, it will still measure and display readings, but will not record data and you won’t be able to use any of the additional features of the EasyLog Cloud, including email and SMS notifications. > www.lascarelectronics.com « electronics **www.lascarelectronics.com** ## **EL-IOT-CO2** ## **Carbon Dioxide WiFi Cloud-Connected Data Logger** ## **Your data, anytime, anywhere** ||||Minimum Reading<br>WiFi signal strength|Minimum Reading<br>WiFi signal strength|||| |---|---|---|---|---|---|---|---| |**DISPLAY STATUS INDICATION**<br>The high-contrast LCD shows current,<br>maximum and minimum readings, as<br>well as alarm and logger status:<br>Battery level<br>Maximum Reading<br>Calibration reminder<br>Warning notification<br>CO2alarm status<br>Temperature alarm status<br>Temperature reading<br>CO2reading<br>CO2units<br>Humidity reading<br>Humidity units<br>Alarm light and mute button<br>z<br>|<br>Aux<br>= OD<br>Nooo<br>PP<br>edo~~e~~<br>m~~ee~~<br>A CAL<br>CO,<br>LL—~~—~~<br>=<br>m~~i~~ccodlocom<br>Z<br>CS|||||||| ||Temperature units|||||Humidity alarm status|| ||||||||| |**Display**<br>**Logger Status**<br>**Startup**<br>~~es~~<br>~~es~~<br>SEHre<br>if £23|**Explanation**<br>**The logger is starting up,**<br>**the number**<br>**displayed is the**<br>**firmware version**|||**Display**<br>**Logger Status**<br>**Firmware Update**<br>~~|~~<br>“oo<br>ud||**Explanation**<br>**The device is loading**<br>**new firmware (you can**<br>**check for updates on**<br>**the EasyLog Cloud)**|| |**Not configured**<br>t} oud<br>not] SEE|**The logger has not**<br>**yet been connected to the**<br>**EasyLog Cloud, readings**<br>**will be displayed but not**<br>**uploaded**|||**Update Failed**<br>PAIL<br>|||**The device has failed**<br>**to load new firmware**<br>**and will automatically**<br>**revert to the previous**<br>**version**|| |**Setup Mode**<br>SEEUP<br>~_--L---|**The device is in setup**<br>**mode, ready to connect to**<br>**the EasyLog Cloud**|||**CO2 Calibration**<br>**Due**<br>LUC!<br>LAL due||**You should activate**<br>**the CO2 Fresh Air**<br>**Calibration process**|| ||||||||| |**Connected to**<br>**App**<br>Pignin<br>App|**The device has**<br>**connected to the**<br>**EasyLog App as part**<br>**of the setup process**|||**CO2 Fresh Air**<br>**Calibration**<br>F-ESh<br>Bye23||**The device is**<br>**recalibrating the CO2**<br>**sensor, leave it exposed**<br>**to fresh air during this**<br>**process**|| |**Not logging**<br>~~“FLL~~<br>Moe<br>555 3|**The device has been**<br>**turned on but can’t con-**<br>**nect to the Cloud, readings**<br>**will be displayed but not**<br>**logged. As soon as the**<br>**device connects to the**<br>**Cloud it will start logging**|**nect to the Cloud, readings**||**CO2 Calibration**<br>**Failed**<br>°|7<br>ian<br>coe CAL||**The device was unable**<br>**to calibrate the CO2**<br>**sensor, you should**<br>**expose it to fresh air**<br>**and try again**|| |**Setup Fail**<br>~~FRL~~<br>eei|**The device has been**<br>**unable to complete the**<br>**setup process, check the**<br>**availability of**<br>**your WiFi network**<br>**and try again**||**Device warning**<br>**Press MIN/MAX to**<br>**cycle through readings**<br>**screens to see warning**<br>**screens**<br>~~a~~||||| The high-contrast LCD shows current, maximum and minimum readings, as well as alarm and logger status: • On startup, the LCD runs through a test sequence in which all elements are activated, the alarm LEDs light up and the sounder beeps. • The CO2 sensor may take a few minutes to self-calibrate after startup, before readings are given. During this time keep in fresh air. **www.lascarelectronics.com** ## **EL-IOT-CO2** ## **Carbon Dioxide WiFi Cloud-Connected Data Logger** ## **Your data, anytime, anywhere** **==> picture [152 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> CONNECTING TO THE CLOUD<br>**----- End of picture text -----**<br> Connect the power supply and the device will turn itself on. **==> picture [9 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>**----- End of picture text -----**<br> **==> picture [10 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> 2<br>**----- End of picture text -----**<br> Download and login to : the EasyLog Cloud App / on your mobile device. Select “Setup Device” } and follow the on| screen instructions to add your EL-IOT-CO2. You can now view the EL-IOT-CO2’s data **3** and change settings either in the EasyLog Cloud App or by visiting your account at: **www.easylogcloud.com** **==> picture [112 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> BUTTON FUNCTIONS<br>**----- End of picture text -----**<br> **Button Press Function Mute alarm sounder (it will TOP BUTTON** - **re-activate when a new alarm is activated) Cycle between current, MIN / MAX minimum and maximum** Short Press **readings, and any warning screens Reset the maximum and** Long Press **minimum values for all CLEAR M/M parameters Create an audit mark in the AUDIT data record and initiate** Short Press **data synchronisation with the Cloud** Long Press **Enter Setup mode CONFIG Reset all active alarms RESET ALARM (they will immediately** Short Press **re-trigger if an alarm threshold is breached) Enter CO Fresh Air** Long Press **2 CALIBRATION Calibration mode** **www.lascarelectronics.com** **Carbon Dioxide WiFi Cloud-Connected Data Logger** ## **EL-IOT-CO2** ## **Your data, anytime, anywhere** ## **CO CALIBRATION 2** - **SPECIFICATIONS** - **CO Measurement 2** - Range 0 to 40,000ppm - ~~——~~ Accuracy 400 to 2,000 ppm ±(50 ppm +5% of reading) - ~~———~~ Resolution 1ppm - ~~—————~~ Auto-calibration Yes - ~~oo~~ Units ppm - ~~————~~ **Temperature Measurement** - ~~$$ —__§—~~ Range -20 to +60°C (-4 to +140°F) - ~~EE~~ Accuracy ±0.3°C (±0.54°F) typical - ~~———EEas~~ Resolution 0.1° - ~~ee~~ Units °C or °F ~~a~~ - **Relative Humidity Measurement** - ~~a~~ Range 0 to 100%RH - ~~a~~ Accuracy ±2% typical Resolution 0.1% - ~~es~~ | Dew Point Accuracy* 1.5°C typical (40 to 100%RH) 10 seconds to 12 hours - Data Logging Rate - ~~—e~~ (user selectable) 1 minute to 24 hours - Transmission Interval (user selectable) - Internal Memory 300,000 readings Dimensions 97 x 87 x 33mm **Operating Temperature** - ~~$_—_§—~~ Battery Power -18 to +55°C (0 to +131°F) - ~~a~~ USB Power -20 to +60°C (-4 to +140°F) - ~~——~~ Environmental Rating Indoor use - ~~———— ST~~ - **Manufactured and supplied by:** Lascar Electronics Ltd Module House Whiteparish, Wiltshire SP5 2SJ United Kingdom To maintain the accuracy of your EL-IOT-CO2, there are two calibration features on the device. Automatic self-calibration ensures the long-term stability without the need for any manual action from the user. This method of calibration assumes that the sensor is exposed to atmospheric CO2 concentrations of ~400ppm at least once per week. Manual recalibration can be carried out to restore the accuracy of the CO2 reading immediately; expose the device to fresh air by placing it outside or next to an open window. Press the CALIBRATE button to start the process and the display will change to show you it is under way. After a few minutes the process will finish and the display will resume showing the current readings. If there are any issues during the process, a warning screen will inform you. Ensure the supply of fresh air is adequate and try again. If your EL-IOT-CO2 ever needs you to carry out a manual calibration, it will prompt you to do so. *Dew point measurements are only available via the EasyLog Cloud This product is not for use within 20cm of the body **www.lascarelectronics.com** **Carbon Dioxide WiFi Cloud-Connected Data Logger** ## **EL-IOT-CO2** ## **Your data, anytime, anywhere** ## **SENSOR ACCURACY AND INFORMATION** Typical and maximal tolerance for the relative humidity sensor at 25°C: Typical and maximal tolerance for the temperature sensor in °C: ## **CO SENSOR 2** **Default conditions of 25°C, 50% RH and ambient pressure of 1013 mbar apply to values in the table below.** |**Parameter**|**Conditions**|**Value**| |---|---|---| |CO2measurement range1|-|0 to 40,000 ppm| |CO2measurement accuracy2|400 to 2,000 ppm|±(50 ppm +5% of reading)| |Repeatability|Typical|±10 ppm| |Response time3|T63%, typical|60 s| |Accuracy drift per year with<br>automatic self-calibration4|Typical|±(5 ppm +0.5% of reading)| 1 Exposure to CO2 concentrations smaller than 400 ppm can affect the accuracy of the sensor if the automatic self-calibration function is used. 2 Deviation to a high-precision reference. Accuracy is fulfilled by >90% of the sensors after calibration. Rough handling or shipping reduces the accuracy of the sensor. Accuracy is restored with the automatic recalibration feature. Accuracy is based on tests with gas mixtures having a tolerance of ±1.5%. 3 Time for achieving 63% of a respective step function under test conditions. Response times can depend on the operating environment in the final application. 4 For proper automatic calibration the device has to be exposed to air with CO2 concentration 400 ppm regularly. Maximum accuracy drift per year estimated from stress tests is ± (5 ppm + 2 % of reading). Higher drift values may occur if the device is not handled according to the instructions. ## **OPERATING CONDITIONS** The performance of the humidity sensor can be affected by long-term exposure to operating conditions at the extents of the logger’s range. The sensor shows best performance when operated within the recommended normal temperature and humidity range of 5 to 55°C and 20 to 80%RH, respectively. Long-term exposure to conditions outside the normal range, especially at high humidity, may temporarily offset the RH signal (e.g. +3%RH after 60h kept at >80%RH). After returning into the normal temperature and humidity range the sensor will slowly come back within the calibration state by itself. Prolonged exposure to extreme conditions may also accelerate ageing. When tracking changes in ambient conditions, the response time of the humidity sensor in your data logger is approximately 20 minutes to reach 90% of the reading. However, if you are measuring step changes in humidity (for example if calibrating the product) it is advised that you leave the unit for up to four hours to ensure that it has enough time to settle at the new level. It is worth remembering that the value of relative humidity is of course sensitive to temperature variation. As an example, at a relative humidity of ~90%RH at ambient temperature, a variation in temperature of 1°C will result in a change of up to -5%RH. Therefore when comparing multiple devices or calibrating them, any temperature variations must be considered. The humidity measuring element in the humidity data loggers can be contaminated through exposure to a variety of compounds. These products should not be kept in proximity to volatile chemicals such as solvents and other organic compounds. Generally speaking, if a material or compound emits a strong odour you should not keep your humidity data logger in close proximity to it. If you would like more information, please contact your local Lascar Electronics office. High levels of pollutants may cause permanent damage to the internal sensor. **www.lascarelectronics.com** **EL-IOT-CO2 Carbon Dioxide WiFi Cloud-Connected Data Logger** **Your data, anytime, anywhere** ## **BATTERY INFORMATION** **==> picture [14 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> INCLUDED IN THE BOX<br>**----- End of picture text -----**<br> **==> picture [235 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> PSU 3 x ADAPTORS CABLE<br>Power supply Power cable<br>**----- End of picture text -----**<br> **EL-IOT WALL BRACKET Wall mounting bracket** This device is designed to be powered using the USB power supply provided. The logger does not lose its stored data readings when the power supply is disrupted. However, if the device has been logging, the logging process will stop and will not resume until the power supply is restored, and the device has reconnected to the WiFi network. To provide a back-up source of power in case the mains supply is lost, you can fit four AA batteries and the product will automatically switch to using them when needed. Use only AA 1.5V alkaline batteries. We recommend you replace the batteries annually. **==> picture [14 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> ACCESSORIES<br>**----- End of picture text -----**<br> **==> picture [14 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> ALSO IN THE RANGE<br>**----- End of picture text -----**<br> ## **CALIBRATION CERTIFICATES** Lascar offers a Traceable Calibration Certificate Service for temperature and humidity sensors. Using reference equipment which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or international standards. For more information please see www.lascarelectronics.com. **BAT 1V5 AA PK4 EL-IOT** calibrated by a UKAS/NIST accredited laboratory **4 x AA 1.5V WALL BRACKET** and using apparatus traceable to national or **alkaline batteries Wall mounting bracket** international standards. For more information **with magnets** please see www.lascarelectronics.com. **TECHNICAL INFORMATION** ~~Tis)~~ Power Supply Voltage 5V, 1A **EL-WEM EL-WEM+ EL-IOT-1** ~~FF~~ **WiFi Indoor Air Quality WiFi High Accuracy Indoor WiFi Ambient temperature** Logger Operating **Monitor Air Quality Monitor data logger** Environment -20 to +60°C (Power Supply) Logger Operating Environment -18 to +55°C (Battery Power) 5% to 85% RH, 75kPa to 106kPa Power Supply Operating Environment[-20 to +40°C] Transportation and **EL-IOT-TC EL-IOT-TH EL-IOT-TH+** -20 to +60°C Storage Environment CLILJ **(Coming Soon) (Coming Soon) (Coming Soon)** ~~==ff~~ **WiFi thermocouple WiFi temperature and WiFi High accuracy temperature** Net Weight 243g **temperature data logger humidity data logger and humidity data logger** ~~FF~~ **lascarelectronics.com/data-loggers to see our to see our** Recommended Wall 3.5 x 20mm, countersunk head, **full range of data loggers and measuring devices** Fixing Screws cross recessed, stainless steel ~~ee eee~~ **Vist lascarelectronics.com/data-loggers to see our to see our full range of data loggers and measuring devices** **www.lascarelectronics.com**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →