EL-GFX-VAC2
Data Logger, -40 to 60°C Measurement Range, Thermistor Probe, 2 Channel, 250K Samples, USB, LCD
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:USB Thermistor; No. of Channels:2Channels; Reading Capacity:250000; Product Range:EL-GFX Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (07-Nov-2024)
- Display Type: LCD
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 250K Samples
- Data Logger Type: Thermistor Probe
- No. of Channels / Inputs: 2 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 254.67 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **EL-GFX-VAC2**
## Dual Channel High Accuracy Thermistor Glycol Probe Data Logger with Graphic Screen
▪ -40 to +60°C (-40 to +140°F) measurement range
- Stores over 250,000 readings
- Logging rates between 2 seconds and 1 hour
- On screen menu and graphing to start, stop, review and restart the logger in the field
- Triggered logging mode to start recording data once a user defined level is met
- High contrast, greyscale, backlit, graphic LCD screen to denote status and alarm levels
- User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
- EasyLog software available as a free download
This standalone data logger measures and stores over 250,000 temperature readings over a -40 to +60°C (-40 to +140°F) range at a resolution of 0.1°C (0.2°F).
The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the available free downloadable EasyLog software. Data can then be graphed, printed and exported to other applications.
The data logger features a high contrast dot-matrix LCD and three buttons to navigate through an on-screen menu. This menu provides the user with access to real-time trend analysis, data summaries and the ability to start, stop and restart the data logger without the need to connect the data logger to the host-PC. Users can reset the maximum / minimum reading using the on-screen menu. This introduces an ‘event marker’ into the data which can later be viewed in the graphing software (‘Mark Events’ option) and the data file after download.
The data logger is supplied complete with two lithium metal batteries, which can typically allow logging for up to 4 months.
## SPECIFICATIONS
## ACCESSORIES
**Type 2 Probe Measurement Range** -40 to 60°C (-40 to 140°F) _(Supplied)_ **Accuracy** _(-10 to 70°C / 14 to 158°F)_ ±0.3°C (±0.5°F) **Accuracy** _(-40 to 60°C / -40 to 140°F)_ ±1°C (±1.8°F) **Accuracy** _(Logger error)_ ±0.1°C (±0.2°F) **Internal Resolution** 0.1°C (0.2°F) ~~———~~ **Logging Rate** Every 2 seconds to 1 hour **Operating temperature Range** -10 to 40°C (14 to 104°F) 4 months ~~a~~ **2X 1/2 AA 3.6V Lithium Battery Life Dimensions** 101 x 48.5 x 30.5mm (3.97 x 1.90 x 1.20”) ~~ee eee~~
**BAT 3V6 1/2AA** Replacement battery (2 required) **EL-P-VAC** Replacement thermistor glycol probe
## INCLUDED IN THE BOX
**x2 BAT 3V6 1/2AA** Battery **CABLE USB A-MICRO B** USB cable **EL-GFX WALL BRACKET** Magnetic mounting bracket **x2 EL-P-VAC** Thermistor glycol probes **CAL-TEMP-UK** Temperature Calibration certificate
## CALIBRATION CERTIFICATES INCLUDED
The EL-GFX-VAC2 comes with a calibration certificate issued at 2 and 8°C, using reference equipment which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or international standards. For more information, please see **www.lascarelectronics.com** .
## **EL-GFX-VAC2** Dual Channel High Accuracy Thermistor Glycol Probe Data Logger with Graphic Screen
## EASYLOG SOFTWARE
Lascar’s EasyLog control software is available as a free download from www.easylogusb.com. Easy to install and use, the control software is compatible with 32-bit and 64-bit versions of Windows 7, 8 and 10. The software is used to set up the logger, download, graph and annotate data or export in Excel, PDF and jpeg formats.
## The software allows the following parameters to be configured:
- Logger name ▪ Measurement parameter (°C or °F) ▪ Logging rate (user selectable between 2 seconds and 1 hour) ▪ Display off, on for 30 seconds after button press, or permanently on ▪ High and low alarms ▪ Disable or enable LEDs and sounder with delayed activation ▪ Immediate, delayed, triggered and push-to-start logging
## **Download the latest version of the software free of charge from www.easylogusb.com**
## MENU BUTTON FUNCTIONS AND LCD SCREEN INDICATION
**==> picture [497 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
START LOGGER c Ly DISPLAY DATA<br>ARMED! button | /bELAYED START|. |DELAYED START ▪ Loggers can be started immediately 26 8 ° 268°C ▪ Data can be displayed on screen in tabular or graphical format<br>start logging h0:30:00Starts logging04/03/12 at whenStarts temperature logging on a button press, delayed to a specific time or delayed to specific . Cc ▪ You can switch between these views by<br>v 30 above 36.2°C temperature reading gfx i: jo<ee tt | zt: [ow pressing the / buttons at the bottom-left of your screen<br>ON-SCREEN ICONS STOP/START LOGGING<br>7 7 ° EE & MUTE ALARM<br>ma +ALARMSLARM# { fj @OLoggerStop LoggingSettings | |@StartOLogger LoggingSettings | |@Mute© Stop AlarmLogging ▪ By pressing the button, you can stop your logger, or view logger settings. =at<br>OLogger Settings If you have already stopped logging, this<br>▪ When the EasyLog cube is ▪ High/Low Alarm indicators ▪ This icon indicates that your option will change to ‘Start Logging’.<br>shown in the top-left corner are displayed at the top of battery is low and will need elyvivielviv feliviv The audible alarm can be muted from<br>your logger is logging your screen to be replaced soon this menu if enabled<br>Temperature SUMMARY DATA LOCKED MODE<br>Max 34.8°C Mem Used 32% ▪ Summary screen displays max/min ▪ When in locked mode - an option<br>Min 22.8°C Readings 6336 log and last log. Reset function clears during PC set-up - the logger can only<br>Since summary if required Locked Mode be stopped and re-started using a PC<br>10:30 24/09/2012 ▪<br>These screens can be reached by loaded with the unit’s configuration<br>wv | reset Be pressing the button |i | ok | 7 [me software<br>POP-UP MESSAGES<br>‘@OstartLogger LoggingSettingsA EasyLogSampleLowHighow AlmAlmANT Rate40°C10°CUSB10s ▪ To view a summary of the logger’s LOGGER SETTINGS ‘StartTimenotunit &ha setoeloggingdate DownloadM90%emoryfulldatais7 loggerMIDownloadlemorystoppedfulldatafull, ▪ A message will overlay the screen - if there is an issue - the next time a<br>S/N [000000001] settings press the button, then click ‘Logger Settings’ using PC to a PC to clear to a PC to clear button is pressed, e.g. if the logger is running low on memory<br>**----- End of picture text -----**<br>
_Please note that screens may vary slightly depending on model._
www.lascarelectronics.com/data-loggers
Issue 4 08/2021 Page 2 of 3
## **EL-GFX-VAC2**
## Dual Channel High Accuracy Thermistor Glycol Probe Data Logger with Graphic Screen
## PROBE MESUREMENT ACCURACY
## BATTERY INFORMATION
## **Replacement**
We recommend that you replace the battery every year, or prior to logging critical data. Only use 3.6V ½AA lithium batteries. The data logger does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and will not resume until the battery is replaced and the logger restarted by EasyLog software.
Before replacing the battery, remove the data logger from the PC. Please note that leaving the data logger plugged into the USB port for extended periods will cause some of the battery capacity to be lost.
## **Passivation**
If left unused for extended periods of time, lithium batteries including those used in the EasyLog range of data loggers naturally form a non-conductive internal layer, preventing them from self-discharge and effectively increasing their shelf life. When first installed in the data logger, this may cause a momentary drop in the battery voltage (the Transient Minimum Voltage) as the internal layer is broken down, resulting in the data logger resetting. Inserting the batteries in the data logger and leaving it connected to a PC for about 30 seconds will remove this layer. After this, remove and re-install the batteries to reset the data logger. Overall battery life will not be affected.
## WARNING
Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations.
www.lascarelectronics.com/data-loggers
Issue 4 08/2021 Page 3 of 3
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →