Image not available
Illustrative purposes only
EL-GFX-DTP+
Data Logger, -40 to 125°C Measurement Range, Temperature Probe, 2 Channel, 250K Samples, USB, LCD
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:USB Thermistor; No. of Channels:2Channels; Reading Capacity:250000; Product Range:EL-GFX Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (07-Nov-2024)
- Display Type: LCD
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 250K Samples
- Data Logger Type: Temperature Probe
- No. of Channels / Inputs: 2 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 175.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Probes** ## Thermistor Probes (Temperature) - Compatible with all EasyLog thermistor probe data loggers listed below - Variety of measurement ranges covering -40 to +125°C temperature range Lascar’s range of thermistor probes are suitable for use with all EasyLog thermistor probe data loggers. They incorporate high accuracy thermistor temperature sensing elements encapsulated in a sealed stainless steel end-cap. The probes can be used in a wide range of applications including manufacturing processes, cold and hot storage and environmental monitoring. A thin and flexible connection cable makes the probes suitable for use within a closed measurement environment e.g. refrigerator, incubator etc. ## EL-P-TP Standard thermistor probe to get you started - -40 to 125°C (-40 to 257°F) measurement range - Accuracy of ±0.5ºC (-10 to 70°C), ±1.0ºC (-40 to 125°C) - 5mm diameter, 25mm length stainless steel capped isolated probe on 1m cable. ## For use with: EL-USB-TP-LCD EL-GFX-DTP EL-WiFi-TP EL-21CFR-TP-LCD EL-WiFi-21CFR-TP EL-SMS-2G-TP EL-SGD 43-ATP EL-SGD 70-ATP ## EL-P-TP+ High accuracy thermistor probe - -40 to 125°C (-40 to 257°F) measurement range - Accuracy of ±0.1ºC (-10 to 70°C), ±0.3ºC (-40 to 125°C) - 5mm diameter, 75mm length stainless steel capped, isolated probe on 3m cable. ## For use with: EL-USB-TP-LCD+ EL-GFX-DTP+ EL-WiFi-TP+ EL-WiFi-DTP+ EL-21CFR-TP-LCD+ EL-WIFI-21CFR-TP+ EL-WIFI-21CFR-DTP+ EL-SMS-2G-TP+ ## EL-P-VAC High accuracy vaccine temperature probe - -40 to 60°C (-40 to 140°F) measurement range - Accuracy of ±0.1ºC (-10 to 60°C), ±0.3ºC (-40 to 60°C) - 40 minute T90 response* - Glycol filled bottle with 3m cable *Based on response to a step temperature change of -10 to 21°C ## For use with: EL-USB-VAC EL-GFX-VAC-2 EL-SMS-2G-VAC EL-WiFi-VAC EL-WiFi-VAC2 EL-21CFR-VAC EL-WiFi-21CFR-VAC EL-WiFi-21CFR-VAC2 www.lascarelectronics.com /data-loggers Issue 3 04/2024 Page 1 of 4 Smart Probes Lascar’s smart probe technology eliminates down time due to calibration testing. No need to send your data logger away for testing. Simply order a pre-calibrated smart probe and swap the new probe for your old one. EL-P-VACX For use with: High accuracy smart vaccine temperature probe EL-WIFI-VACX • -40 to +60°C (-40 to +140°F) measurement range • Accuracy of ±0.1ºC (-10 to 60°C), ±0.3ºC (-40 to 60°C) • Glycol filled bottle with 3m cable EL-P-TPX+ For use with: High accuracy smart temperature probe EL-WIFI-TPX+ • -40 to +125°C (-40 to +257°F) measurement range • ±0.2/±0.4 (-15 to +80˚C / +5 to +176˚F) ±0.6/±1.1 (-40 to +125˚C / -40 to +257˚F) • 75mm stainless steel capped, 3m cable ~ EL-PROBE-EXTENDER For use with: A choice of 1.5m, 3m, 5m or 10m extender cables EL-P-TP EL-WiFi-TP for all probes EL-P-TP+ EL-21CFR-TP-LCD EL-P-VAC EL-WiFi-21CFR-TP • Male 3.5mm Jack to Female 3.5mm Socket EL-P-VACX EL-SMS-2G-TP • Gold plated connections to limit signal loss EL-P-TPX+ EL-SGD 43-ATP EL-USB-TP-LCD EL-SGD 70-ATP EL-GFX-DTP ~~&~~ EL-MOTE-P-TP For use with: Temperature thermistor probe EL-MOTE-TP EL-MOTE-TP+ • -40 to +125˚C (-40 to +257˚F) measurement range EL-MOTE-DTP • Accuracy of ±0.8 (-15 to +70˚C) ±1.5 (-40 to +125˚C) ~~ EL-MOTE-DTP+ - -40 to +125˚C (-40 to +257˚F) measurement range • Accuracy of ±0.8 (-15 to +70˚C) ±1.5 (-40 to +125˚C) • 75mm stainless steel capped, 3m cable ## For use with: ## EL-MOTE-P-TP+ High accuracy temperature thermistor probe EL-MOTE-TP EL-MOTE-TP+ EL-MOTE-DTP EL-MOTE-DTP+ - -40 to +125˚C (-40 to +257˚F) measurement range - Accuracy of ±0.2 (-15 to +80˚C) ±0.6 (-40 to +125˚C) - 5mm diameter, 75mm stainless steel capped, 3m cable ## EL-MOTE-P-T Temperature thermistor probe ## For use with: EL-MOTE-T - -20 to +60˚C (-4 to +140˚F) measurement range - Accuracy of ±0.5 (-20 to +60˚C) ## EL-MOTE-P-T+ High accuracy temperature thermistor probe ## For use with: EL-MOTE-T+ - -20 to +60˚C (-4 to +140˚F) measurement range - Accuracy ±0.15 (0 to +60˚C) ±0.21 (-20 to +60˚C) www.lascarelectronics.com /data-loggers Issue 3 04/2024 Page 2 of 4 ## Thermocouple Probes (High & low temperature ranges) - Compatible with all EasyLog thermocouple data loggers listed below - Mini-thermocouple type connector - Variety of measurement ranges covering -100 to 700°C (-148 to 1292°F) Lascar’s range of EasyLog thermocouple data loggers are designed to work with K, J and T-Type thermocouples fitted with a mini-thermocouple type connector. Your particular application will determine which probe is most suitable based on temperature range, accuracy, form and price. For specialist applications or advice, please contact your EasyLog distributor. ## EL-P-TC-K Basic thermocouple probe to get you started - 0 to 200°C (32 to 392°F) measurement range - Accuracy of ±2.5ºC (±4.5ºF) - 3mm diameter, 100mm stainless steel isolated - probe on 1.5mm cable. ## EL-P-TC-K-SPIKE High accuracy temperature probe with a wide measurement range - -100 to 700°C (-148 to 1292°F) measurement range - Accuracy of ±1.5°C (±3°F)** - 3.3mm diameter stainless steel isolated probe on 125m cable - ** Over -40 to 375°C range ## EL-P-TC-T-SURFACE Silicone Rubber patch thermocouple - -50 to 150°C (-58 to 302°F) Measurement range - Accuracy of ±0.5°C - 30 x 14 x 3.4mm Patch on 1.5m cable ## For use with: EL-USB-TC EL-USB-TC-LCD EL-GFX-TC EL-GFX-DTC EL-WiFi-TC EL-WiFi-DTC EL-21CFR-TC EL-WiFi-21CFR-TC EL-WiFi-21CFR-DTC WA-PRO-TC ## For use with: EL-USB-TC EL-USB-TC-LCD EL-GFX-TC EL-GFX-DTC EL-WiFi-TC EL-WiFi-DTC EL-21CFR-TC EL-WiFi-21CFR-TC EL-WiFi-21CFR-DTC WA-PRO-TC ## For use with: EL-USB-TC EL-USB-TC-LCD EL-GFX-TC EL-GFX-DTC EL-WiFi-TC EL-WiFi-DTC EL-21CFR-TC EL-WiFi-21CFR-TC EL-WiFi-21CFR-DTC WA-PRO-TC ## EL-SP-TC Smart thermocouple probe including EL-P-TC-K - Temperature measurement range of -200 to +1300°C (-328 to +2372°F). The K-type probe provided with the product measures between 0 to +200°C (+32 to +392°F) and other electrically isolated thermocouple probes can be used. - Accuracy of ±1ºC (±2ºF) + Probe error ## For use with: EL-MOTE-TC EL-MOTE-DTC EL-IOT-TC EL-SIE-TC WA-PRO-TC WA-PRO-ULT WA-PRO-ULT+ - 3mm diameter, 100mm stainless steel isolated probe on 1.5m cable - Compatible with all K, J & T type thermocouples for extended range* - Probe tips must be kept electrically isolated. If metal sheathed probes are used, check thet the sheath is isolated from the probe junction. If it is not or you are using an unsheathed probe, ensure that the probe tip is insulated. www.lascarelectronics.com /data-loggers Issue 3 04/2024 Page 3 of 4 For use with: ## EL-P-TC-T-ULT Ultra Low Temperature probes for cryogenic vaccine monitoring - -100 to +100°C (-148 to +212°F) - measurement range - Accuracy of ±2.5°C (±4.5°F) typical - 150mm stainless steel isolated probe on a 2m cable EL-USB-ULT EL-USB-ULT-LCD EL-21CFR-USB-ULT EL-WiFi-ULT EL-WiFi-DULT EL-21CFR-WiFi-ULT EL-21CFR-WiFi-DULT EL-MOTE-ULT EL-MOTE-DULT EL-IOT-ULT EL-SIE-ULT WA-PRO-ULT ## EL-P-TC-T-ULT+ ## For use with: EL-USB-ULT+ EL-USB-ULT-LCD+ (¥ High Accuracy Ultra Low Temperature probes for cryogenic vaccine monitoring EL-USB-ULT+ EL-USB-ULT-LCD+ EL-21CFR-USB-ULT+ EL-WiFi-ULT+ EL-WiFi-DULT+ EL-21CFR-WiFi-ULT+ EL-21CFR-WiFi-DULT+ EL-MOTE-ULT+ EL-MOTE-DULT+ EL-IOT-ULT+ EL-SIE-ULT+ WA-PRO-ULT+ - -100 to +100°C (-148 to +212°F) - measurement range - Accuracy of ±1.8°C (±3.2°F) typical - 300mm stainless steel isolated probe on 2m cable ## Temperature and Humidity Probe ## EL-SP-TH Temperature and humidity probe - -30 to +80ºC (-22 to +176ºF) temperature measurement range ## For use with: EL-MOTE-TH EL-IOT-TH EL-SIE-TH - Temperature accuracy of ±0.3 (+5 to +60ºC) ±0.8 (-20 to +60ºC) - 0 to 100%RH humidity range - Humidity accuracy of ±2%RH (20 to 80%RH) at 25ºC - 2m cable ## EL-SP-TH+ High accuracy temperature and humidity probe - -30 to +80ºC (-22 to +176ºF) temperature measurement range ## For use with: EL-MOTE-TH+ EL-IOT-TH+ EL-SIE-TH+ - Temperature accuracy of ±0.2 (+5 to +60ºC) ±0.8 (-20 to +60ºC) - 0 to 100%RH humidity range - ±1.8%RH (20 to 80) ±4%RH (0 to 100) humidity accuracy at 25ºC - 2m cable ## EL-GFX-SP-2 Temperature and humidity probe ## For use with: EL-GFX-D2 - -30°C to 80°C (-22°F to 176°F) - temperature measurement range - 0 to 100%RH humidity measurement range - 2m cable www.lascarelectronics.com /data-loggers Issue 3 04/2024 Page 4 of 4
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →