EL-GFX-D2
Data Logger, -30 to 80°C Temperature, 0 to 100% RH, Temperature, Humidity & Dew Point, 2 Channel
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:USB Temperature, Humidity & Dew Point; No. of Channels:2Channels; Reading Capacity:250000; Product Range:EasyLog Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (07-Nov-2024)
- Display Type: LCD
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 250K Samples
- Data Logger Type: Temperature, Humidity & Dew Point
- No. of Channels / Inputs: 2 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 165.36 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **EL-GFX-D2** Dual Channel Temperature, Humidity and Dew Point Data Logger with External Probe ## FEATURES - Dual channel Temp, RH and Dew Point data logger with external probe (supplied with x1 probe) - -30 to +80°C (-22 to +176°F) and 0 to 100%RH measurement ranges - Stores over 250,000 readings per channel for temperature and humidity - Logging rates between 10 seconds and 1 hour - On screen menu and graphing to start, stop, review and restart the logger in the field - Triggered logging mode to start recording data once a user defined level is met - User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs - Supplied with EasyLog software for Windows This standalone data logger measures and stores over 250,000 temperature and humidity readings over a -30 to +80°C (-22 to +176°F) and 0 to 100%RH range at a resolution of 0.1°C (0.2°F) and 0.1%RH. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the EasyLog USB software, free to download from **www.lascarelectronics.com/sofware/easylog-usb** . Data can then be graphed, printed and exported to other applications. The data logger features a high contrast dot-matrix LCD and three buttons to navigate through an on-screen menu. This menu provides the user with access to real-time trend analysis, data summaries and the ability to start, stop and restart the data logger without the need to connect the data logger to the host-PC. Users can reset the maximum / minimum reading using the onscreen menu; this introduces an ‘event marker’ into the data which can later be viewed in the graphing software (‘Mark Events’ option) and the data file after download. The data logger is supplied complete with two lithium metal batteries, which can typically allow logging for up to 1 year. It can also be powered from USB. ## SPECIFICATIONS |**Temperature**|**Measurement Range**|-30°C to 80°C (-22°F to 176°F)| |---|---|---| ||**Internal Resolution**|0.1°C (0.2°F)| ||**Accuracy (overall error)**|± 0.3°C (0.6°F) typical| |**Relative Humidity**|**Measurement Range**|0 to 100%RH| ||**Internal Resolution**|0.1%RH| ||**Accuracy (overall error)**|± 2.05%RH typical (20 to 80%RH)| ||**Long Time Stability**|0.5%RH / year| |**Dew Point**|**Accuracy (overall error)**|± 1.1°C typical (±2.0°F)| |**Logging Rate**||Between 10 seconds and 1 hour| |**Battery Life***||1 year2 x ½ AA 3.6V| |**Dimensions of logger**||101 x 48.5 x 30.5mm (3.98 x 1.91 x 1.20”)| |**Probe Dimensions**||37 x 12 x 8mm (1.5 x 0.5 x 0.3”)| |**Cable Length**||2000mm (79”)| * At 25°C and 10 minute logging rate with no alarm LEDs or sounder and minimal LCD use. www.lascarelectronics.com/data-loggers Issue 3 07/2022 Page 1 of 4 ## **EL-GFX-D2** Dual Channel Temperature, Humidity and Dew Point Data Logger with External Probe ## EASYLOG SOFTWARE Lascar’s EasyLog USB control software is available to download from www.lascarelectronics.com/software. Easy to install and use, the control software runs under Windows™ 7/8/10 (32 & 64bit). The software is used to set-up the data logger as well as download, graph and export data to Excel. Each stored logging session is saved as a separate file. The software allows the following parameters to be configured: - Logger name - Measurement parameter (°C or °F) - Logging rate (customisable between 10 seconds and 1 hour) - High and low temperature alarms on each channel - Immediate, delayed, triggered and push-to-start logging - Disable or enable LEDs and sounder with delayed activation - Display off, on for 30 seconds after button press, or permanently on ## **Download the latest version of the software free of charge from www.lascarelectronics.com/software** ## MENU BUTTON FUNCTIONS AND LCD SCREEN INDICATION **==> picture [497 x 248] intentionally omitted <==** **----- Start of picture text -----**<br> START LOGGER ¢ q DISPLAY DATA<br>ARMED! button | DELAYED START|. DELAYED START ▪ Loggers can be started immediately 26 8 ° 26.8°C ▪ Data can be displayed on screen in tabular or graphical format<br>start logging Starts logging at hentemacrare on a button press, delayed to a specific time or delayed to specific . . ▪ You can switch between these views by<br>v p.0:30:00 04/03/42] |" pn ag °c temperature reading gfx a Ee EE: a7 ES pressing the / buttons at the bottom-left of your screen<br>ON-SCREEN ICONS STOP/START LOGGING<br>a a Dy & MUTE ALARM<br>ma +tALARMSLoARKSLARM+ a | @OLogger Stop LoggingSettings | |@StartOLogger LoggingSettings | |@Mute© Stop Logging Alarm ▪ By pressing the button, you can stop your logger, or view logger settings. Ea<br>OLogger Settings If you have already stopped logging, this<br>▪ When the EasyLog cube is ▪ High/Low Alarm indicators ▪ This icon indicates that your option will change to ‘Start Logging’.<br>shown in the top-left corner are displayed at the top of battery is low and will need elyvivielvivtelviv The audible alarm can be muted from<br>your logger is logging your screen to be replaced soon this menu if enabled<br>Temperature SUMMARY DATA LOCKED MODE<br>Max 34.8°C Mem Used 32% ▪ Summary screen displays max/min ▪ When in locked mode - an option<br>Min 22.8°C Readings 6336 log and last log. Reset function clears during PC set-up - the logger can only<br>Since summary if required Locked Mode be stopped and re-started using a PC<br>10:30 24/09/2012 ▪ These screens can be reached by loaded with the unit’s configuration<br>wv | reset p>) pressing the button |i | gix i ~< software<br>‘SuneeerStart Li eats. EasyLogSampleLow. AlmRate10°CUSB6, 10s ▪ To view a summary of the logger’s LOGGER SETTINGS StartTimenotunit & set datelogging DownloadMemory90% fulldatais loggerMemoryDownloadstoppeddatafull, ▪ A message will overlay the screen - if there is an issue - the next time a POP-UP MESSAGES<br>S/NHigh Alm000000001 40°C settings press the button, then click ‘Logger Settings’ using PC to a PC to clear to a PC toclear button is pressed, e.g. if the logger is running low on memory<br>**----- End of picture text -----**<br> _Please note that screens may vary slightly depending on model._ www.lascarelectronics.com/data-loggers Issue 3 07/2022 Page 2 of 4 ## **EL-GFX-D2** Dual Channel Temperature, Humidity and Dew Point Data Logger with External Probe ## DIMENSIONS All dimensions in mm (inches) **==> picture [439 x 282] intentionally omitted <==** **----- Start of picture text -----**<br> 33 (13)<br>30 (11.8)<br>[<br>(Lt Wy LU<br>(| ll (7<br>61 (24)<br>hp Ce<br>van 49 (19.3) \)<br>30 (11.8)<br>100 (39.4)<br>**----- End of picture text -----**<br> ## BATTERY INFORMATION We recommend that you replace the batteries every 4 months, or prior to logging critical data. ## **Replacement** The EL-GFX-D2 does not lose its stored readings when the batteries are discharged or when the batteries are replaced; however, the data logging process will be stopped. If the batteries are changed within a 2 minute window the EL-GFX-D2 will retain its settings (internal clock and logging mode). This will allow logging to be restarted without additional connection to a PC via USB. Only use 2 x 3.6V ½AA lithium batteries. Do not mix battery types and do not mix new and old batteries. Before replacing the batteries, unplug the EL-GFX-D2 from the PC. ## **Passivation** If left unused for extended periods of time, the Lithium batteries used in the EasyLog range of data loggers naturally form a nonconductive internal layer, preventing them from self-discharge and effectively increasing their shelf life. When first installed in the data logger, this may cause a momentary drop in the battery voltage (the Transient Minimum Voltage) as the internal layer is broken down, resulting in the data logger resetting. Inserting the batteries in the data logger and leaving it connected to a PC for about 30 seconds will remove this layer. After this, remove and re-install the batteries to reset the data logger. Overall battery life will not be affected. ## WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. www.lascarelectronics.com/data-loggers Issue 3 07/2022 Page 3 of 4 ## **EL-GFX-D2** Dual Channel Temperature, Humidity and Dew Point Data Logger with External Probe ## SENSOR ACCURACY & INFORMATION TH probe = Sensirion, SHT21 accuracy graph (EL-GFX-SP-2) ## **ΔT (°C)** **==> picture [213 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> ± 2.0<br> maximum error<br>± 1.5 typical accuracy<br>± 1.0 \<br>RK Wa<br>± 0.5<br>± 0.0<br>-40 -20 0 20 40 60 80<br>Temperature (°C)<br>**----- End of picture text -----**<br> Typical and maximal tolerance for temperature sensor in °C. ## **ΔRH (%RH)** **==> picture [268 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> ± 10<br> maximum error<br>± 8 typical accuracy<br>± 6<br>“XN L<br>± 4 je ee ec<br>± 2<br>± 0<br>0 10 20 30 40 50 60 70 80 90 100<br>Relative Humidity (%RH)<br>**----- End of picture text -----**<br> Typical and maximal tolerance at 25°C for relative humidity. ## Operating conditions **==> picture [531 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> 100 ±3.5 ±3 ±3.5 ±4 100 PT | TT PET<br>90 ±2.5 ±3 ±3.5<br>80 het ret<br>80 ±3 ±3.5 we} ft|| ETtT tr<br>70 ±3 ±2.5 ±3 60 et EE<br>60 i i}itt | tT | tT | te Normal tt | ttte TN Max. NY<br>50 ±2.5 ±2 40 P\E Range PER Range<br>Py} T V}NE | | TttT tT tE t EE ATA<br>40 20 Post XP ey ttNS<br>30<br>CESSES<br>20 0 ieeeeee eee ee<br>10 ±3 ±2.5<br>-40 -20 0 20 40 60 80 100 120<br>0 ±3.5 ±3 Temperature (°C)<br>0 10 20 30 40 50 60 70 80<br>Temperature (°C)<br>Relative Humidity (%)<br>Relative Humidity (%RH)<br>**----- End of picture text -----**<br> Long term exposure to humidity levels outside of the ‘normal’ range may temporarily offset RH measurements (±3%RH after 60 hours). Once returned to less extreme conditions the device will slowly return towards calibration state. Typical accuracy of relative humidity measurements given in %RH for temperatures 0 to 80°C. www.lascarelectronics.com/data-loggers Issue 3 07/2022 Page 4 of 4
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →