Image not available
Illustrative purposes only
EL-21CFR-1-LCD
Data Logger, -35 to +80°C Measurement Range, Temperature, 1 Channel, 16379 Samples, USB, LCD
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:USB Temperature; No. of Channels:1Channels; Reading Capacity:16379; Product Range:EL-21CFR Series; SVHC:No SVHC (15-Jan-2019)
- SVHC: No SVHC (07-Nov-2024)
- Display Type: LCD
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 16379 Samples
- Data Logger Type: Temperature
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 84.35 € |
| Current stock | 10+ |
| Lead time | 30 days |
**EL-21CFR-1-LCD** EasyLog 21CFR Compatible Temperature Data Logger with LCD Screen - -35 to +80°C (-31 to +176°F) measurement range - Stores over 16,000 readings - EasyLog 21CFR software available as a free download - Logging rates between 10 seconds and 12 hours - High contrast LCD, with two and a half digit temperature display function - Immediate, delayed and push-to-start logging - User-programmable alarm thresholds - Use as part of a 21CFR Part 11 compliant system This standalone data logger measures and stores more than 16,000 temperature readings over a -35 to +80°C (-31 to +176°F) range with a resolution of 0.5°C (1°F). The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the free EasyLog 21CFR software. Data can then be graphed, printed and exported to other applications for detailed analysis. The encrypted data has full audit tracking to comply with the requirements of 21CFR Part 11. The high contrast LCD can show a variety of temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored values for temperature. The data logger is supplied with a lithium metal battery which gives two years’ logging life. The logger is protected against ingress from water and dust to IP67 standard when the cap is fitted. ## SPECIFICATIONS ## ACCESSORIES **==> picture [309 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Measurement range|-35 to +80°C (-31 to +176°F)| |Internal resolution|0.5°C (1°F)| |Accuracy (overall error)|+/- 0.5°C typical (see graph on page 4)| |Logging rate|User selectable between 10 seconds & 12 hours| |Operating temperature range|-35 to +80°C (-31 to +176°F)| |Battery Life|2 years (at 25°C and 1 minute logging rate, LCD on)| |Readings|16,379| |Dimensions|120 x 25 x 22mm (4.72 x 0.98 x 0.86”)| **----- End of picture text -----**<br> **==> picture [169 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |BAT 3V6 1/2AA|Replacement battery| |INCLUDED IN THE BOX| |BAT 3V6 1/2AA|Battery| |EL-LCD WALL BRACKET|Mounting Bracket| **----- End of picture text -----**<br> ## CALIBRATION CERTIFICATES NOW AVAILABLE Lascar now offers a Traceable Calibration Certificate Service on Temperature Data Loggers. Using reference equipment which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or international standards. For more information, please see **www.lascarelectronics.com** . www.lascarelectronics.com/data-loggers Issue 5 02/2017 Page 1 of 4 **EL-21CFR-1-LCD** EasyLog 21CFR Compatible Temperature Data Logger with LCD Screen ## STORE DATA IN COMPLIANCE WITH THE REGULATIONS OF 21CFR PART 11 Easy to install and use, Lascar’s **EasyLog 21CFR software** is compatible with all latest versions of Windows (7, 8 & 10 - both 32-bit & 64-bit) and is available as a free download from **www.lascarelectronics.com/software/easylog-21cfr** . All data collected from the logger and associated audit trails are stored in an encrypted format which cannot be edited. ## CONTROL YOUR LOGGER Users can configure their loggers with the following parameters: - Logger name - Temperature measurement parameter (°C or °F) - Logging rate (user selectable between 10 seconds and 12 hours) - High and low alarms for temperature - Immediate, delayed and push-to-start logging mode Once users have recorded data, the built-in graphing software allows them to graph and annotate their data, or export it to Excel, PDF or jpeg formats. ## CONTROL YOUR DATA EasyLog 21CFR software ensures digital security and compliance: - Assign individual users with specific permissions - Full software & session data audit trails - Receive email alerts for failed log in attempts - Digital signatures added to all reports - Add comments to specific readings For more information, and to download the latest version of the software free of charge, visit: www.lascarelectronics.com/software/easylog-21cfr www.lascarelectronics.com/data-loggers Issue 5 02/2017 Page 2 of 4 ## **EL-21CFR-1-LCD** ## EasyLog 21CFR Compatible Temperature Data Logger with LCD Screen ## DISPLAY STATUS INDICATION The EL-21CFR-1-LCD features a high contrast LCD which shows logged temperature values using seven segment numbers, along with annunciators. The LCD can also show information regarding the logging status. The LCD shows three different recorded readings, which can be cycled through using the built-in push button. The most recent logged temperature, maximum logged temperature and minimum logged temperature can be displayed. **Maximum logged value symbol** | **Negative symbol** yoo VILILES°C°F | | | **Minimum logged Reading Temperature value symbol scale** |**Display**<br>~~es~~|**Logger Status**<br>~~nsnn~~|**Explanation**<br>~~nn~~| |---|---|---| |~~es~~|Delayed Start<br>~~nsnn~~|This is shown when the logger is set to start at a specific date and time. If the logger is set to ‘LCD off’ or ‘LCD<br>on for 30 seconds’ mode, then this will only be shown after the button is pressed. Otherwise the display will<br>remain blank<br>~~nn~~| |~~re~~|Push to Start|This is shown when the logger is set up for ‘Push to Start’ logging| |~~re~~<br>~~ee~~|Logging|This is shown when the logger is running in ‘LCD off’ mode, and the button is pressed. The display clears again<br>after three seconds| |~~re~~<br>~~ee~~|Stopped|If the logger has not been set to log and the button is pressed, three dashes are displayed for a few seconds| ## LED STATUS INDICATION The EL-21CFR-1-LCD features two LEDs: - The first LED flashes **red** to indicate that the EL-21CFR-1-LCD is in an alarm condition. It will flash when the logged temperature has exceeded a Low or High alarm level. - The second LED flashes **green** to indicate that the EL-21CFR-1-LCD is not in an alarm condition. Using EasyLog 21CFR it is possible to set the alarm to remain active even if the reading has returned to normal, in which case the alarm LED will continue to flash red. This ‘Hold’ feature in the software ensures the user is notified that at some point an alarm level has been exceeded, without needing to download the data. Hold is enabled by default, and can be turned off via the control software. The red LED will then only flash whilst the logger is in an alarm condition. When the temperature returns to normal, the green LED will flash. **Green single flash (every 10 seconds)** The data logger is not currently logging, but is primed to start at a later ~~Co~~ date and time (delayed start) **Green single flash (every 20 seconds)** The data logger is currently logging. No alarm ~~Oo.~~ **Green single flash (every 30 seconds)** oO The data logger is full and has stopped logging. No alarm **Green double flash (every 20 seconds)** The data logger is currently logging. Low alarm ~~6~~ **Red single flash (every 10 seconds)** The data logger is full and has stopped logging. Low alarm ~~oO~~ **Red single flash (every 20 seconds)** The data logger is currently logging. High alarm ~~Oo.~~ **Red double flash (every 10 seconds)** The data logger is full and has stopped logging. High alarm ~~6~~ **Red double flash (every 20 seconds)** The battery is running low. Data logging will continue until the battery ~~Ce~~ voltage drops below 2.8V **Red/Green single flash (every 20 seconds)** The battery is running low. Data logging will continue until the battery voltage drops below 2.8V ~~Co~~ **No LEDs flash** ~~Oo.~~ The data logger is stopped, the battery is empty or there is no battery www.lascarelectronics.com/data-loggers Issue 5 02/2017 Page 3 of 4 ## **EL-21CFR-1-LCD** ## EasyLog 21CFR Compatible Temperature Data Logger with LCD Screen **==> picture [109 x 38] intentionally omitted <==** ## MEASUREMENT ACCURACY **==> picture [194 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> ± 2.0<br>± 1.5<br>± 1.0<br>± 0.5<br>± 0.0<br>-40 -20 0 20 40 60 80<br>Temperature (°C)<br>Accuracy (°C)<br>**----- End of picture text -----**<br> ## BATTERY INFORMATION ## **Replacement** We recommend that you replace the battery annually, or prior to logging critical data. Only use 3.6V ½AA lithium metal batteries. The data logger does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and will not resume until the battery is replaced and the logger restarted by the EasyLog 21CFR Software. Before replacing the battery, remove the data logger from the PC. Please note that leaving the data logger plugged into the USB port for extended periods will cause some of the battery capacity to be lost. ## **Passivation** If left unused for extended periods of time lithium metal batteries, including those used in the EasyLog range of data loggers, naturally form a non-conductive internal layer preventing them from self-discharge and effectively increasing their shelf life. When first installed in the data logger, this may cause a momentary drop in the battery voltage (the Transient Minimum Voltage) as the internal layer is broken down, resulting in the data logger resetting. Inserting the batteries in the data logger and leaving it connected to a PC for about 30 seconds will remove this layer. After this, remove and re-install the batteries to reset the data logger. Overall battery life will not be affected. ## WARNING Handle lithium metal batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. www.lascarelectronics.com/data-loggers Issue 5 02/2017 Page 4 of 4
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →