Image not available
Illustrative purposes only
EL USB-1
Data Logger, -35 to 80°C Measurement Range, Temperature, 1 Channel, 16382 Samples, USB
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: LASCAR
- Product type:
- Data Logger Type:USB Temperature; No. of Channels:-; Reading Capacity:16382; Product Range:EasyLog; SVHC:No SVHC (15-Jan-2019); Input Voltage:3.6V
- SVHC: No SVHC (07-Nov-2024)
- Display Type: LED Indicator
- Product Range: EasyLog Series
- Data Interface: USB
- Maximum Samples: 16382 Samples
- Data Logger Type: Temperature
- No. of Channels / Inputs: 1 Channel
- Sensor / Measurement Type: -
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 39.64 € |
| Current stock | 25+ |
| Lead time | 30 days |
## **EL-USB-1** Temperature Data Logger - -35 to +80°C (-31 to +176°F) measurement range - Stores over 16,000 readings - EasyLog software available as a free download - Logging rates between 10 seconds and 12 hours - Immediate and delayed logging start - User-programmable alarm thresholds - Status indication via red/green and amber LEDs - Environmental protection to IP67 This standalone data logger measures and stores more than 16,000 temperature readings over a -35 to +80°C (-31 to +176°F) range with a resolution of 0.5°C (1°F). The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the free EasyLog software. Data can then be graphed, printed and exported to other applications for detailed analysis. The data logger is supplied with a lithium metal battery which gives three year’s logging life. The logger is protected against ingress from water and dust to IP67 standard when the cap is fitted. ## EASYLOG SOFTWARE Lascar’s EasyLog control software is available as a free download from www.easylogusb.com. Easy to install and use, the control software is compatible with 32-bit and 64-bit versions of Windows 7, 8 and 10. The software is used to set up the logger, download, graph and annotate data or export in Excel, PDF and jpeg formats. The software allows the following parameters to be configured: - Logger name - Measurement parameter (°C or °F) - Logging rate (user selectable between 10 seconds and 12 hours) - High and low alarms • Immediate and delayed logging start ## ~~ee~~ **Download the latest version of the software free of charge from www.lascarelectronics.com/software/easylog-usb** |SPECIFICATIONS|SPECIFICATIONS||ACCESSORIES| |---|---|---|---| ||**Measurement range**<br>**Internal resolution**<br>**Accuracy (overall error)**|-35 to +80°C (-31 to +176°F)<br>0.5°C (1°F)<br>+/- 0.5°C typical(see graph on page 2)|**BAT 3V6 1/2AA**<br>Replacement<br>battery<br>**EL-USB-CASE**<br>Protective metal<br>case| ||**Logging rate**|User selectable between 10 seconds & 12 hours|| ||**Operating temperature range**|-35 to +80°C (-31 to +176°F)|INCLUDED IN THE BOX| ||**Battery Life**<br>**Readings**<br>**Dimensions**|3 years(at 25°C and 1 minute logging rate)<br>16,382<br>99 x 25 x 23mm (3.89 x 0.98 x 0.90”)|**BAT 3V6 1/2AA**<br>Battery<br>**EL-USB WALL BRACKET** Mounting Bracket| ## CALIBRATION CERTIFICATES NOW AVAILABLE Lascar now offers a Traceable Calibration Certificate Service on Temperature Data Loggers. Using reference equipment which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or **www.lascarelectronics.com/data-loggers** international standards. For more information, please see **www.lascarelectronics.com** . > Issue 18 04/2024 Page 1 of 2 <SZS ## **EL-USB-1** Temperature Data Logger ## LED STATUS INDICATION The EL-USB-1 features two LEDs: a green/ red LED to indicate logging and alarm status, and an amber LED to indicate a possible problem. In normal operation the green LED will flash, but will change to red if an alarm condition has been triggered. Using EasyLog software it is possible to set the alarm to remain active even if the reading has returned to normal, in which case the alarm LED will continue to flash red. This ‘Hold’ feature in the software ensures the user is notified that at some point an alarm level has been exceeded, without needing to download the data. |ly,~~Co~~<br>~~Co~~|**Green double flash**<br>The data logger is not currently logging, but is primed to start at a later date<br>and time (delayed start)<br>~~Co~~<br>~~Co~~| |---|---| |~~Co~~<br>~~Co~~<br>~~COC~~|**Green single flash**<br>The data logger is currently logging. No alarm<br>~~Co~~<br>~~Co~~<br>~~COC~~| |~~Co~~<br>~~COC~~<br>~~COO~~|**Green and Amber single flash**<br>The data logger is full and has stopped logging. No alarm<br>~~Co~~<br>~~COC~~<br>~~COO~~| |~~COC~~<br>~~COO~~<br>~~COC~~|**Red single flash**<br>The data logger is currently logging. Low alarm<br>~~COC~~<br>~~COO~~<br>~~COC~~| |~~COO~~<br>~~COC~~<br>~~CO~~|**Red and Amber single flash**<br>The data logger is full and has stopped logging. Low alarm<br>~~COO~~<br>~~COC~~| |~~COC~~<br>~~CO~~<br>~~OC~~|**Red double flash**<br>The data logger is currently logging. High alarm<br>~~COC~~<br>~~OC~~| |~~CO~~<br>ly<br>ly,<br>~~OC~~|**Red and Amber double flash**<br>The data logger is full and has stopped logging. High alarm<br>~~OC~~| |~~OCOo~~|**Amber single flash**<br>The battery is running low. Data logging will continue until the battery voltage<br>drops below 2.8V<br>~~OCOo~~| |~~Oo~~|**No LEDs flash**<br>The data logger is stopped, the battery is empty or there is no battery<br>~~Oo~~| ## BATTERY INFORMATION ## **Replacement** We recommend that you replace the battery annually, or prior to logging critical data. Only use 3.6V ½AA lithium metal batteries. The data logger does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will stop and will not resume until the battery is replaced and the logger restarted by EasyLog software. Before replacing the battery, remove the data logger from the PC. Please note that leaving the data logger plugged into the USB port for extended periods will cause some of the battery capacity to be lost. ## **Passivation** If left unused for extended periods of time lithium metal batteries, including those used in the EasyLog range of data loggers, naturally form a non-conductive internal layer preventing them from self-discharge and effectively increasing their shelf life. When first installed in the data logger, this may cause a momentary drop in the battery voltage (the Transient Minimum Voltage) as the internal layer is broken down, resulting in the data logger resetting. Inserting the batteries in the data logger and leaving it connected to a PC for about 30 seconds will remove this layer. After this, remove and re-install the batteries to reset the data logger. Overall battery life will not be affected. ## WARNING Handle lithium metal batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. ## MEASUREMENT ACCURACY **==> picture [194 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> ± 2.0<br>± 1.5<br>± 1.0<br>± 0.5<br>± 0.0<br>-40 -20 0 20 40 60 80<br>Temperature (°C)<br>Accuracy (°C)<br>**----- End of picture text -----**<br> ~~|~~ **www.lascarelectronics.com/data-loggers** Issue 18 04/2024 Page 2 of 2
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →