EHL05US24
AC/DC PCB Mount Power Supply (PSU), ITE, Industrial & Household, 1 Output, 5 W, 24 VDC, 210 mA
- Manufacturer: XP POWER
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: No SVHC (23-Jan-2024)
- Depth: 52.4mm
- Width: 27.2mm
- Height: 23mm
- Product Range: EHL05 Series
- No. of Outputs: 1 Output
- Output Power Max: 5W
- Input Voltage VAC: 85V AC to 528V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 210mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE, Industrial & Household
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 11.49 € |
| Current stock | 10+ |
| Lead time | 30 days |
AC-DC POWER SUPPLIES ## **EHL05** Series ## 5W The EHL05 series of PCB mount single output power supplies deliver 5W of power and offer single output voltages ranging from 3.3V to 48V. The EHL05 series is available in both open-frame and encapsulated mechanical formats. These high power-density power supplies feature a wide 85-528 VAC input, specifically designed for phase-to-phase operation in a 480 VAC system. The EHL05 series also offers OVC III compliance, Class II construction, worldwide industrial and household safety approvals, making it suitable for a wide range of industrial applications and control systems in commercial and residential buildings. ## **Features** ## **Applications** - Phase to neutral or phase to phase operation - Overvoltage category III - Wide 85-528VAC input range - Single voltage outputs from 3.3V to 48VDC **==> picture [125 x 25] intentionally omitted <==** **----- Start of picture text -----**<br> Industrial Security 3 Phase<br>Electronics Power Supplies<br>& Robotics<br>**----- End of picture text -----**<br> - Encapsulated or open-frame formats - IEC Class II construction - Industrial and household safety approvals - -40°C to +80°C operating temperature ## **Dimensions** EHL05: 52.4 x 27.2 x 23.0mm (2.06” x 1.07” x 0.91”) ## EHL05-P: 49.3 x 25.0 x 22.4mm (1.94” x 0.98” x 0.88”) ## **Models & Ratings** |Model Number(1)<br>EHL05US03|Output Voltage<br>3.3VDC|Output Current<br>1.52A|Efficiency(2)<br>75%|Output Power<br>5W| |---|---|---|---|---| |EHL05US05|5.0VDC|1.00A|80%|5W| |EHL05US09|9.0VDC|0.56A|83%|5W| |EHL05US12|12.0VDC|0.42A|83%|5W| |EHL05US15|15.0VDC|0.33A|83%|5W| |EHL05US24|24.0VDC|0.21A|84%|5W| |EHL05US48|48.0VDC|0.105A|85%|5W| Notes: 1. For Open Frame version add suffix -P to model number, e.g. EHL05US12-P. 2. Typical efficiency at 115VAC and full load. AC-DC POWER SUPPLIES ## **EHL05** Series ## **Summary** **==> picture [541 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons|Notes & Conditons| |---|---|---|---|---|---|---| |Input Voltage Range|85||528|VAC|Derate from 100% at 90 VAC to 90% at 85VAC|| |No Load Input Power|||0.3|W||| |Effciency||85||%|Model dependent, see Models & Ratings|| |Operating Temperature|-25||+80|°C|3V3 & 5V models|Derate output linearly from 100% at +45°C to<br>60% at +80°C for encapuslated, +70°C for open<br>frame| ||-40||+80||Other models|Derate output linearly from 100% at +60°C to<br>60% at +80°C for encapsulated, +75°C for open<br>frame| |EMC|EN55032 Level B Conducted & Radiated, EN61000-3-2, EN61000-3-3, EN55035|||||| |Safety Approvals|IEC62368-1, EN62368-1, UL62368-1, IEC60335-1|||||| ## **Input** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Input Voltage Range|85||528|VAC|Derate from 100% at 90VAC to 90% at 85VAC| |Input Frequency|47||63|Hz|| |Input Current - Full Load||0.2/0.1||A rms|At 115/230VAC| |No Load Input Power|||0.3|W|| |Inrush Current|||40|A|At 230VAC, cold start 25°C| |Earth Leakage Current|Class II construction no earth||||| |Input Protection|External 2.0A/600V fuse required||||| |Overvoltage Category|OVC III||||| ## **Output** **==> picture [540 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Output Voltage|3.3||48|VDC|| |Initial Set Accuracy|||1.0|%|At 50% load| |Minimum Load|0|||A|No minimum load required| |Line Regulation|||0.5|%|| |Load Regulation|||1.0||| |Start Up Delay|||2|s|| |Start Up Rise Time|||35|ms|| |Hold Up Time|8|14||ms|At full load and 115VAC| |Transient Response|||4|%|Deviation, recovery within 1% in less than 500μs for a 25% load<br>change| |Ripple & Noise|||50|mV pk-pk|3.3-9V models, 20MHz bandwidth at 25°C and 230VAC input| ||||0.5|% pk-pk|Other models, 20MHz bandwidth at 25°C and 230VAC input| |Overvoltage Protection|115||140|% Vnom|Auto recovery| |Overload Protection|110||200|%|| |Short Circuit Protection|Trip & Restart (hiccup mode)||||| |Temperature Coeffcient|||0.05|%/°C|| 2 AC-DC POWER SUPPLIES ## **EHL05** Series ## **General** |Characteristic<br>Efficiency|Minimum|Typical<br>85|Maximum|Units<br>%|Notes & Conditions<br>Model dependent| |---|---|---|---|---|---| |Isolation: Input to Output|4000|||VAC|| |Switching Frequency|17||75|kHz|Varies with load| |Power Density|||19.5|W/cm3|For ‘-P’ version| |Mean Time Between Failure|550|600||khrs|MIL-HDBK-217F, +25°C GB| |Weight||23.0 (0.051)||g (lb)|Open frame versions (-P)| |||70.0 (0.154)|||Encapsulated version| ## **Environmental** |Characteristic<br>Operating Temperature|Minimum<br>-25|Typical|Maximum<br>+80|Units<br>°C|Notes & Conditions<br>3V3 & 5V models<br>Derate output linearly from 100% at +45°C<br>to 60% at +80°C for encapsulated, +70°C<br>for open frame|Notes & Conditions<br>3V3 & 5V models<br>Derate output linearly from 100% at +45°C<br>to 60% at +80°C for encapsulated, +70°C<br>for open frame| |---|---|---|---|---|---|---| ||-40||||Other models|Derate output linearly from 100% at 60°C to<br>60% at +80°C for encapsulated, +75°C for<br>open frame| |Storage Temperature|-40||+85|°C||| |Cooling|Convection-cooled|||||| |Humidity|||95|%RH|Non-condensing|| |Operating Altitude|||4000|m||| |Shock|IEC68-2-27, 30g, 11ms half sine, 3 times in each of 6 axes|||||| |Vibration|IEC68-2-6, 2g, 10Hz to 500kHz, 10 mins/cycle, 60 mins each cycle|||||| **==> picture [524 x 283] intentionally omitted <==** **----- Start of picture text -----**<br> Efficiency Graphs<br>EHL05US12-P EHL05US24-P<br>100% 100%<br>90% 90%<br>80% 80%<br>70% 115VAC230VAC 70% 115VAC230VAC<br>60% 60%<br>50% 50%<br>40% a 40%<br>10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100<br>Load Load<br>EMC: Emissions<br>Phenomenon Standard Test Level Notes & Conditions<br>Conducted EN55032 Class B Class B with external components, see application notes<br>Radiated EN55032 Class B Class B with external components, see application notes<br>Harmonic Current EN61000-3-2 Class A<br>Voltage Flicker EN61000-3-3<br>Efficiency<br>**----- End of picture text -----**<br> **==> picture [53 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> EHL05US12-P<br>**----- End of picture text -----**<br> 3 AC-DC POWER SUPPLIES ## **EHL05** Series ## **EMC: Immunity** **==> picture [540 x 599] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & Conditions<br>±6kV contact,<br>ESD Immunity EN61000-4-2 A<br>±8kV air discharge<br>Radiated Immunity EN61000-4-3 10 V/m A<br>EFT/Burst EN61000-4-4 3 A<br>Surge EN61000-4-5 2 A Line to line<br>Conducted EN61000-4-6 10Vrms A<br>Magnetic Fields EN61000-4-8 10A/m A<br>70% UT (80.5VAC) for 100ms A<br>EN61000-4-11 40% UT (46VAC) for 200ms B<br>(115VAC) <5% UT (0VAC) for 10ms A<br>Dips and Interruptions <5% UT (0VAC) for 5000ms B<br>70% UT (161VAC) for 100 ms A<br>EN61000-4-11 40% UT (92VAC) for 200ms A<br>(230VAC) <5% UT (0VAC) for 10ms A<br><5% UT (0VAC) for 5000ms B<br>Safety Approvals<br>Certification Standard Notes & Conditions<br>CB IEC62368-1 ITE<br>UL UL62368-1 ITE<br>EN62368-1 ITE<br>TUV<br>EN60335-1 Household and similar<br>CE Meets all applicable directives<br>UKCA Meets all applicable legislation<br>Application Notes<br>EMC with Output Grounded<br>L2<br>L3<br>CX1 +Vo<br>CX2 EHL05<br>L1 CY1 -Vo<br>PE<br>Pin Connections<br>CX1, CX2 X2 CAP 15mm 18 x 14.5 8.5mm 0.47μF/305VAC 10% X2(MPX) B STE<br>L3 CMCK DIP UU-9.8 Φ 0.20mm/150T 35mH (min)<br>CY1 Y1 CAP 7.5mm 680pF/400VAC 10% JD B JEC<br>**----- End of picture text -----**<br> This product will meet Class A emissions with no external components. For Class B operation, additional components are required. 4 AC-DC POWER SUPPLIES ## **EHL05** Series ## **Mechanical Details** **==> picture [398 x 566] intentionally omitted <==** **----- Start of picture text -----**<br> Encapsulated 52.4 (2.06)<br>13.6<br>45.72 (1.800) (0.54)<br>3.3 (0.13)<br>10.16<br>(0.400)<br>2<br>27.2<br>(1.07) TOP VIEW 3<br>3.4<br>(0.14)<br>1 4<br>20.32<br>(0.800) 23.0<br>(0.91)<br>10.0<br>(0.39)<br>4-ø 1.00 (0.039)<br>10.16<br>49.3 (1.94) (0.400)<br>12.5<br>Open Frame (-P)<br>(0.49)<br>1.8 (0.07)<br>2<br>25.0<br>3<br>2.3 (0.98)<br>(0.09)<br>1 4<br>20.32 (0.800)<br>19.0<br>(0.75)<br>3.4 max<br>(0.13)<br>3.8<br>(0.15)<br>22.4<br>4-ø 1.00 (0.039) 2.5 (0.88)<br>(0.10)<br>4-ø 1.80 (0.071)<br>45.72 (1.800)<br>**----- End of picture text -----**<br> |Pin Connectons|Pin Connectons| |---|---| |Pin|Single| |1|L1| |2|L2| |3|+Vout| |4|-Vout| ## **Notes:** 1. Dimensions in mm (inches). 2. Weight: Open frame versions (-P): 23g (0.051lbs) Encapsulated: 70g (0.154lbs) 3. Tolerances: x.xx = (x.x = ±0.5) ±0.02) x.xxx = x.xx = ±0.25 (±0.01) **==> picture [148 x 49] intentionally omitted <==** 5 22 Jan 2024
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →