- Manufacturer: DWYER
- Product type: Pressure Switches
- Pressure Type:Differential; Pressure Port Type:-; Operating Pressure Min:0.08Inch-H2O; Operating Pressure Max:1.2Inch-H2O; Contact Configuration:SPDT; Switching 82AK4498
- SVHC: No SVHC (25-Jun-2025)
- Deadband Max: 0.05Inch-H2O
- Deadband Min: 0.04Inch-H2O
- Pressure Type: Differential
- Product Range: EDPS Series
- Sensor Mounting: Panel Mount
- Pressure Port Size: 1/4"
- Pressure Port Type: -
- Contact Configuration: SPDT
- Electrical Connection: Screw
- Switching Current Max: 1.5A
- Switching Voltage Max: 250VAC
- Operating Pressure Max: 1.2Inch-H2O
- Operating Pressure Min: 0.08Inch-H2O
- Operating Temperature Max: 85°C
- Operating Temperature Min: -20°C
- Transducer Connection / Termination: Screw
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 41.15 € |
| Current stock | 10+ |
| Lead time | 30 days |
Duyer **SERIES ADPS/EDPS/BDPA** ## HVAC DIFFERENTIAL PRESSURE SWITCHES With Dual Scale Field Adjustable Set Point Knob **==> picture [540 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> 2-9/16 [65]<br>HVAC DIFFERENTIAL PRESSURE SWITCHES Ø11/64 2-1/4 [57] 1-31/32<br>With Dual Scale Field Adjustable Set Point Knob IP 54[Ø4.5] 21/64 45/64[18] [50] YEAR LIMITEDWARRANTY<br>[8.5]<br>LED<br>Audible Test/snooze 2-21/64<br>buzzer button [59]<br>; e. - N -/ 4 NN 8 OO<br>: N Lis 5 rq Battery AP Pred ] | | a<br>9/32 [7] Ø15/64<br>(* a Power i i a Contact 51/64 [18] Je - + AE [Ø6]<br>input output CABLE GLAND INSERT [P2] [P1]<br>ADPS EDPS BDPA ADPS<br>2-9/16 [65]<br>Ø11/64 2-1/4 [57] 1-31/32 2-17/64 2-9/16 [65]<br>IP 54[Ø4.5] 21/64 45/64[18] [50] Ø11/64[Ø4.5] [57.5] [22]7/8 1-31/32[50]<br>[8.5] 21/64<br>[8.5]<br>(( O )) I 2-21/64 ho) (es 5 (eel<br>2-21/64<br>[59]<br>[59]<br>51/64 [18] - + 9/32 [7] Ø15/64[Ø6] 51/64 [18] 19/64 [7.5] Ø15/64[Ø6]<br>CABLE GLAND INSERT [P2] [P1] [P2] - + [P1]<br>>>) _|-i lL a J-i ak<br>N EDPS S BDPA<br>VIDEOONLINE<br>**----- End of picture text -----**<br> The **Series ADPS/EDPS/BDPA HVAC Differential Pressure Switches** are designed for pressure, vacuum, and differential pressures. The dual scaled adjustment knob in inches water column and pascals allows changes to the switching pressure to be made without a pressure gage. The ADPS/EDPS/BDPA are available with settings from 0.08 in w.c. (20 Pa) up to 20 in w.c. (5000 Pa). The silicone diaphragm and PA 6.6 body make the series ADPS ideal for use with air and other noncombustible gases. Series EDPS models meet UL508 and are constructed of plenum rated plastics. The series BDPA Adjustable Differential Pressure Alarms offer a versatile range of configurations allowing utilization of their many features including buzzer and LED notification, and battery or line powered. The compact size, adjustment knob and low cost make the ADPS/EDPS/BDPA the perfect choice for HVAC applications. ## **SPECIFICATIONS** **Service:** Air and non-combustible, compatible gases. **Wetted Materials:** ADPS: Diaphragm material: Silicone; Housing material: POM; Switch body: PA 6.6; Cover: Polystyrene; EDPS: Diaphragm material: Silicone; Housing material: Switch body: PA 6.6; Cover: Polystyrene; Materials UL 94 V-0 rated. **Temperature Limits:** Process and ambient temperature from -4 to 185°F (-20 to 85°C). **Storage:** -40 to 185°F (-40 to 85°C). **Pressure Limits:** Max. operating pressure: 40 in w.c. (10 kPa) for all pressure ranges. **Switch Type:** Single-pole double-throw (SPDT). ## **BENEFITS/FEATURES** **Electrical Rating:** Max. 1.5 A res./0.4 A ind./250 VAC, 50/60 Hz; Max. switching rate: 6 cycles/min. - Adjustment knob changes switching pressure easily with a pressure gage reducing components for application **Electrical Connections:** Push-on screw terminals. M20x1.5 with cable strain relief or optional 1/2˝ NPT. - Low cost device makes it an excellent solution in BAS and HVAC applications requiring duct control and monitoring **Process Connections:** 5/16˝ (7.94 mm) outside diameter tubing, 1/4˝ (6.0 mm) inside diameter tubing. - Relay contact allows simple integration with DDC or building systems **Enclosure Rating:** NEMA 13 (IP54). ## **APPLICATIONS** **Mounting Orientation:** Vertically, with pressure connections pointing downwards. **Mechanical Working Life:** Over 10[[6]] switching operations. **Weight:** 4.4 oz (125 g). • Air filter and ventilator monitoring • Ventilation duct monitoring **Mechanical Working Life:** Over 10[[6]] switching operations. • Industrial cooling circuits • Fan heater overheating protection **Weight:** 4.4 oz (125 g). • Fire-protection damper control • Heat exchanger frost protection **Compliance:** ETL approved to UL508 and CSA C22.2#14 (EDPS only). **MODEL CHART - ADPS ACCESSORIES Set Point Range Approx. Dead Band @ Approx. Deadband @ Model Description Model in w.c. (Pa) Min Set Point in w.c. (Pa) Max Set Point in w.c. (Pa) A-288** “L” type metal mounting bracket with screws **ADPS-08-2-N** 0.08 to 1.20 (20-300) 0.04 (10) 0.05 (12) **A-289** “S” type metal mounting bracket with screws **ADPS-04-2-N** 0.12 to 1.60 (30-400) 0.06 (15) 0.09 (23) **A-480** Plastic static pressure tip **ADPS-03-2-N** 0.20 to 2.00 (50-500) 0.08 (20) 0.09 (23) **A-481** Installer kit, includes 2 plastic static pressure tips and 7´ **ADPS-05-2-NADPS-06-2-N** 0.80 to 4.00 (200-1000)2.00 to 10.00 (500-2500) 0.4 (100)0.6 (150) 0.5 (130)0.8 (200) **A-489** (2.1 m) of PVC tubing4˝ straight static pressure tip with fange **ADPS-07-2-N** 4.00 to 20.00 (1000-5000) 1.0 (250) 1.4 (350) **Note:** For optional 1/2˝ NPT conduit connection, change -2-N to-1-N. Models that include installer kit add -C to the end of the model number (-2-N cable gland models only). Installer kit includes two static tips and 7 ft of PVC tubing. Order installer kit separately with 1/2˝ NPT conduit connection models. ~~i~~ See A-481 in the accessories list. Consult factory for bulk packaging option. ~~ap~~ :; **A-480 MODEL CHART - EDPS Set Point Range Approx. Dead Band @ Approx. Dead Band @ Model in w.c. (Pa) Min Set Point in w.c. (Pa) Max Set Point in w.c. (Pa) EDPS-08-1-N** 0.08 to 1.20 (20-300) 0.04 (10) 0.05 (12) **EDPS-04-1-N** 0.12 to 1.60 (30-400) 0.06 (15) 0.09 (23) **EDPS-03-1-N** 0.20 to 2.00 (50-500) 0.08 (20) 0.09 (23) **EDPS-05-1-N** 0.80 to 4.00 (200-1000) 0.4 (100) 0.5 (130) **EDPS-06-1-N** 2.00 to 10.00 (500-2500) 0.6 (150) 0.8 (200) **EDPS-07-1-N** 4.00 to 20.00 (1000-5000) 1.0 (250) 1.4 (350) **Note:** For optional M20 cable gland connection, change -1-N to-2-N. ## **MODEL CHART - BDPA** |**Model**|**Set Point Range**<br>**in w.c.(Pa)**|**Approx. Dead Band @**<br>**Min Set Point in w.c.(Pa)**| |---|---|---| |**BDPA-08-2-N**<br>**BDPA-04-2-N**<br>**BDPA-03-2-N**<br>**BDPA-05-2-N**<br>**BDPA-06-2-N**<br>**BDPA-07-2-N**|0.08 to 1.20 (20 to 300)<br>0.12 to 1.60 (30 to 400)<br>0.20 to 2.00 (50 to 500)<br>0.80 to 4.00 (200 to 1000)<br>2.00 to 10.00 (500 to 2500)<br>4.00 to 20.00(1000 to 5000)|)<br>0.04 (10)<br>0.06 (15)<br>0.08 (20)<br>0.4 (100)<br>0.6 (150)<br>1.0(250)| **Process Tubing Options: See page 453 (Gage Tubing Accessories)** DWYER INSTRUMENTS, LLC | dwyer-inst.com **45**
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →