ECS25US24
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 25 W, 80V AC to 264V AC
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):25W; Power Rating (Forced Cooling):-; Input Voltage VAC:80V AC to 264V AC; Power Supply Output Type:Adjustable, Fixed; O
- SVHC: No SVHC (15-Jan-2018)
- Product Range: ECS25 Series
- No. of Outputs: 1 Output
- Output Power Max: 25W
- Input Voltage VAC: 80V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 80V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 1.04A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 25W
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 21.99 € |
| Current stock | 10+ |
| Lead time | 30 days |
**25-60 Watts** ~~AE~~ xppower.com **ECS Series** - IT & Medical Safety Approvals - Very Small 2” x 3” x 0.95” Package - <0.3 W No Load Input Power - 25, 45 & 60 W - Convection Cooled Ratings - Class I & Class II Installations - -20 °C to +70 °C Operation - 3 Year Warranty ## ~~**Specification**~~ ## **Input** - Input Voltage • 80-264 VAC (120-370 VDC), derate linearly from 100% at 90 VAC to 80% at 80 VAC - Input Frequency • 47-63 Hz Input Current • 25 W: 0.45 A, 45 W: 0.75 A, 60 W: 0.95 A typical at 115 VAC, full load, 25 W: 0.30 A, 45 W: 0.45 A, 60 W: 0.60 A, typical at 230 VAC, full load - Inrush Current • 40 A max at 230 VAC, cold start 25 ˚ C Power Factor • EN61000-3-2, class A No Load Input Power • US05, 12 & 24 models: <0.3 W, US48 and all ECS60 models: <0.5 W - Earth Leakage Current • 260 μ A at 264 VAC/60 Hz max, 80/160 μ A typical 115/230 VAC - Input Protection • T3.15 A/250 V internal fuse in line and neutral ## **Output** Output Voltage • 5-48 VDC (see tables) Output Voltage Trim • ±10% Initial Set Accuracy • ±1% Minimum Load • No minimum load required Start Up Delay • 1 s typical Start Up Rise Time • 50 ms Hold Up Time • 16 ms min at 115 VAC Drift • ±0.2% after 20 min warm up Line Regulation • ±0.5% max Load Regulation • ±1% Over/Undershoot • 5% typical Transient Response • 4% max. deviation, recovery to within 1% in 500 μ s for a 50-75-50% load change Ripple & Noise • 1% pk-pk V1, 20 MHz bandwidth[(1) ] Overvoltage Protection • 115-140% Vnom, recycle input to reset Overload Protection • 110-160% Short Circuit Protection • Continuous trip and restart (hiccup mode) Temperature • 0.05%/ ˚ C Coefficient ## ~~**Notes**~~ _1. ECS60US12 1.5% pk-pk, 20 MHz bandwidth under certain line/load conditions._ _2. See longform datasheet or contact sales for details._ ## **General** - Efficiency • Up to 90%, model dependant Isolation • 4000 VAC In to Out, 2 x MOPP, 1500 VAC In to Earth, 1 x MOPP, 500 VDC Out to Earth, 1 x MOPP - Switching Frequency • 65 KHz typical Power Density • Up to 7.9 W/in[3] MTBF • 25 & 45 W: 1072 kHrs, 60 W: 471 kHrs to MIL-HDBK-217F at 25 ˚ C, GB ## **Environmental** - Operating Temperature • at 2.5%/-20 ˚ C to +70 ˚ C to 50% load at +70 ˚ C derate linearly from +50 ˚ C. ˚ C Cooling • Convection, see thermal considerations Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 ˚ C to +85 ˚ C Operating Altitude • 3000 m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes - **EMC & Safetyy** Low Voltage PSU EMC • EN61204-3, high severity level Emissions • All models: EN55011/32 level B conducted. 45 & 60 W: EN55011/32 level A radiated, ECS25 & ECS60US24/48 models: level B radiated - Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, installation class 3 Perf Criteria A - Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A Dips & Interruptions • EN61000-4-11 , 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B , EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation. - Safety Approvals • IEC60950-1:2005 Ed 2 / IEC62368-1:2014 UL 62368-1 & CAN/CSA C22.2 No. 623681-14, EN62368-1:2014/A11:2017, IEC60601-1 CB report, ANSI/AAMI ES60601-1, TUV 60601-1, Including Risk Management, CE & UKCA meets all applicable directives & legislation. ## **EMC & Safetyy** - Equipment Protection • Class I and Class II Class **ECS25** ## ~~**Models and Ratings**~~ |Output Power|Output Voltage|Output Current|Model Number(1)| |---|---|---|---| |25 W|12.0 VDC|2.08 A|ECS25US12| |25 W|15.0 VDC|1.67 A|ECS25US15| |25 W|24.0 VDC|1.04 A|ECS25US24| |25 W|48.0 VDC|0.52 A|ECS25US48| ## ~~**Notes**~~ _1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations, derate output power by 20% with cover._ ## ~~**Mechanical Details**~~ **==> picture [293 x 192] intentionally omitted <==** **----- Start of picture text -----**<br> 4 x Ø.156 (3.96) Mounting Holes<br>2.75 (69.8) Ø.312 (7.92) Clearance Top and Bottom<br>2 1<br>J1 2<br>1 C5 C18 3 J2<br>4<br>1.75 2.00<br>(44.4) 1.65 (50.8)<br>1.31 (41.8)<br>(33.3) T1<br>k= | = er<br>0.27 Q1 0.20<br>(7.0) _ 0.25 (0.6) Faston Ground Tab L L (5.1)<br>3.00 (76.2)<br>0.14 (3.6)<br>0.95 (24.2) SMD Height<br>ane<br>**----- End of picture text -----**<br> **==> picture [112 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> In put Connector J1<br>Molex PN 09-65-2038<br>Pin 1 Line<br>Pin 2 Neutral<br>0.25” Faston Earth<br>Output Connector J2<br>Molex PN 09-65-2048<br>Pin 1 +V1<br>Pin 2 +V1<br>Pin 3 RTN<br>Pin 4 RTN<br>**----- End of picture text -----**<br> J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series 5194 Crimp Terminals Faston ground tab requires insolated receptacle ## **Notes** 1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 2. Weight 0.22 lbs (100 g) ## ~~**Covered version (All ECS25-60 Models)**~~ **==> picture [519 x 246] intentionally omitted <==** **----- Start of picture text -----**<br> 4 x M3 x 0.5 THD 4 x M3 x 0.5 THD<br>0.16 (4.0) Max 0.16 (4.0) Max<br>Screw Penetration Screw Penetration 1.26 0.63<br>(32.0) (16.0)<br>J2 Output Connector 0.22 (5.7)<br>essa] 1 4 G80 Z80 a<br>O@ckRQRO Oxo | |<br>OROXOROS OHO | | 3.03<br>3.48 (76.99)<br>(88.4) 3.03 OROROROS Coo | |<br>(76.9) @Reearee © ! |<br>O-MORD OL | |<br>a) OO | |<br>2 J1 1<br>0.22 (5.7) — i J L | b v8] | O 4 4<br>0.70 InputConnector Top View 0.25 (0.6) Faston Ground Tab 2.52<br>(17.79) (64.0)<br>Bottom View<br>, 1.23 (31.28) - SO J<br>1.40<br>(35.6)<br>Notes<br>1. All dimensions in inches (mm).<br>Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)<br>2. Weight 0.5 lbs (230 g)<br>**----- End of picture text -----**<br> **ECS45** ## ~~**Models and Ratings**~~ |Output Power|Output Voltage|Output Current|Model Number(1)| |---|---|---|---| |30 W|5.0 VDC|6.00 A|ECS45US05| |45 W|12.0 VDC|3.75 A|ECS45US12| |45 W|15.0 VDC|3.00 A|ECS45US15| |45 W|24.0 VDC|1.90 A|ECS45US24| |45 W|48.0 VDC|0.95 A|ECS45US48| ## ~~**Notes**~~ _1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations, derate output power by 20% with cover._ ## ~~**Mechanical Details**~~ **==> picture [473 x 463] intentionally omitted <==** **----- Start of picture text -----**<br> 4 x Ø.156 (3.96) Mounting Holes<br>5 V version 2.75 (69.9) Ø.312 (7.92) Clearance Top and Bottom<br>2<br>J1 1<br>1 C5 C18 32 J2 2.00<br>Molex PN 09-65-2038In put Connector J1 1.75 4 (50.8)<br>(44.5) 1.58<br>Pin 1 Line (40.3)<br>Pin 2 Neutral 1.30<br>0.25” Faston Earth (33.0) T1<br>Out put Connector J2<br>Molex PN 09-65-2048<br>Q1<br>Pin 1 +V1 0.28 0.20<br>(7.0) 0.25 (0.6) Faston Ground Tab (5.1)<br>Pin 2 +V1<br>Pin 3 RTN 3.00 (76.2)<br>Pin 4 RTN<br>rs :<br>J1 mates with Molex Housing PN 09-50-1031, 1.05<br>J2 mates with Molex Housing (26.7)<br>PN 09-50-1041 and both with Molex Series<br>5194 Crimp Terminals 0.14 (3.6) SMD Height Limit<br>Faston ground tab requires insolated receptacle Ped<br>12-48 V version 2.75 (69.9) 4 x Ø.156 (3.96) Mounting HolesØ.312 (7.92) Clearance Top and Bottom<br>2 1<br>J1 2<br>In put Connector J1 1 C5 C18 3 J2<br>Molex PN 09-65-2038 4 2.00<br>Pin 1 Line 1.75 1.65 (50.8 )<br>(44.5) (41.8)<br>Pin 2 Neutral<br>0.25” Faston Earth (33.3)1.31 T1<br>Out put Connector J2<br>Molex PN 09-65-2048<br>Pin 1 +V1 Q1<br>0.28 0.20<br>Pin 2 +V1 (7.0) 0.25 (0.6) Faston Ground Tab (5.1)<br>Pin 3 RTN 3.00 (76.2)<br>Pin 4 RTN<br>J1 mates with Molex Housing PN<br>09-50-1031, J2 mates with Molex Housing PN 09-50-1041 and (24.2)0.95 SMD Height0.14 (3.6)<br>**----- End of picture text -----**<br> J2 mates with Molex Housing PN 09-50-1041 and both with Molex Series 5194 Crimp Terminals Faston ground tab requires insolated receptacle ## **Notes** 1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 2. Weight 0.22 lbs (100 g) **ECS60** ## ~~**Models and Ratings**~~ |Output Power|Output Voltage|Output Current|Model Number(1)| |---|---|---|---| |40 W|5.0 VDC|8.00 A|ECS60US05| |60 W|12.0 VDC|5.00 A|ECS60US12| |60 W|15.0 VDC|4.00 A|ECS60US15| |60 W|24.0 VDC|2.50 A|ECS60US24| |60 W|48.0 VDC|1.25 A|ECS60US48| ## ~~**Notes**~~ _1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations, derate output power by 20% with cover._ ## ~~**Mechanical Details**~~ **==> picture [404 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> 4 x ø0.156 (3.96) mounting holes 0.28 (7.1) 0.20 (5.1) 1.05 (26.7)<br>ø3.12 (7.92) clearance top and bottom<br>A<br>1 J2<br>C18<br>2.00 C5<br>(50.8)<br>1.75 4<br>T (44.4) EA B o p<br>1.62<br>1.30 (41.1)<br>(33.0) T1<br>A<br>Q1<br>! (3.18)0.12 0.25 faston ground tab Components may extend beyond 0.14 (3.5)<br>0.12 2.75 (69.8) edge of PCB<br>(3.1) by 0.04 (1.0)<br>3.00 (76.2)<br>Mounting points A should be connected together for optimum EMI performance<br>**----- End of picture text -----**<br> |In put Connector J1||Out put Connector J2|| |---|---|---|---| |Molex PN 09-65-2038||Molex PN 09-65-2048|| |Pin 1<br>Line||Pin 1<br>+V1<br>Pin 2<br>+V1|| |Pin 2<br>Neutral||Pin 3<br>RTN|| |0.25” Faston<br>Earth||Pin 4<br>RTN|| |J1 mates with Molex Housing PN 09-50-1031||J2 mates with Molex Housing PN 09-50-1041|J2 mates with Molex Housing PN 09-50-1041| |Faston ground tab requires insolated receptacle||and both with Molex Series 5194 Crimp Terminals|| |||Faston ground tab requires insolated receptacle|| ## **Notes** 1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25) 2. Weight: 0.22 lbs (100 g) ## ~~**Thermal Considerations (All ECS25-60 Models)**~~ In order to ensure safe operation of the PSU in the most adverse conditions permitted in the end-use equipment, the temperature of the components listed in the table must not be exceeded. See mechanical drawings for component locations. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). |Temperature Measurements(Ambient≤50 °C)|Temperature Measurements(Ambient≤50 °C)| |---|---| |Component|Max Temperature ºC| |T1|120 °C| |Q1|110 °C| |C5|105 °C| |C18|105 °C| 27 July 2022
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →