ECP60UT01
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 3 Output, 60 W, 85V AC to 264V AC
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- Product Range: ECP60 Series
- No. of Outputs: 3 Output
- Output Power Max: 60W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Approvals: ITE & Medical
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 7A
- Output Current - Output 2: 3A
- Output Current - Output 3: 300mA
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: 12VDC
- Output Voltage - Output 3: -12VDC
- Power Rating (Convection Cooling): 60W
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 38.43 € |
| Current stock | 10+ |
| Lead time | 30 days |
**60 Watts** xppower.com ## **ECP Series** - Low Profile Design - Compact Size, 4” x 2” - IT & Medical Approvals - Dual and Triple Output - <0.5 W No Load Input Power - Peak Load Capability - 3 Year Warranty ## ~~**Specification**~~ ## **Input** |**Inputputut**|| |---|---| |Input Voltage|• 85-264 VAC, derate from 100% load at| ||90 VAC to 90% load at 85 VAC| |Input Frequency|• 47-63 Hz| |Input Current|• 0.85 A max at 115 VAC| |Inrush Current|• 100 A max at 230 VAC, cold start at 25 °C| |Power Factor|• EN61000-3-2, class A| |No Load Input Power|• <0.5 W| |Earth Leakage Current<br>Input Protection|• <250μA at 264 VAC, 60 Hz<br>• Internal T2 A/250 V fuse in both| ||line and neutral| ## **Output** - Output Voltage • See table Output Voltage Trim • ±10% on V1 only, output 2 on multi output models will track by the same percentage - Minimum Load • 10% minimum load required on all outputs of multi output models - Start Up Delay • 1.3 s max Start Up Rise Time • 15 ms typical Hold Up Time • 16 ms min at full load at 115 VAC Total Regulation • Output 1: 2% from 0% load to 100% load Output 2: 5% from 20% load to 100% load Output 3: 5% from 10% load to 100% load - Transient Response • 4% max deviation, recovering to less than 1% within 500 μ s for 50% step load change at 1 A/ μ s - Ripple & Noise • 1% pk-pk measured with 20 MHz bandwidth - Overvoltage Protection • 115-140% of nominal output voltage on V1 only, recycle input to reset - Overload Protection • 120-160% of nominal power Short Circuit Protection • Trip and restart (hiccup mode) Temperature • ±0.02%/°C max Coefficient ## **General** - Efficiency • 88% typical at 230 VAC and full load Isolation • 4000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground - Switching Frequency • 30-130 kHz variable MTBF • >400 kHrs to MIL-HDBK-217F at 25 °C, GB ## **Environmental** |**Environmental**|| |---|---| |Operating Temperature|• -20 °C to +70 °C, derate from 100% load| ||at 50 °C to 50% load at 70 °C| |Cooling|• Natural convection| |Operating Humidity|• 5% to 95% RH, non condensing| |Operating Altitude|• 3000 m max| |Storage Temperature|• -40 °C to +85 °C| |Shock|• 30 g pk, half sine, 6 axes| |Vibration|• 2 g rms, 5 Hz to 500 Hz, 3 axes| ## **EMC & Safety** - Emissions • EN55011/32, level B conducted & level A radiated - Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, ±4 kV indirect contact, Perf Criteria A - Radiated Immunity • EN61000-4-3, 3 V/m, Perf Criteria A EFT / Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 2 Perf Criteria A Conducted Immunity • EN61000-4-6, 3 V Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - Safety Approvals • UL62368-1, IEC62368-1, EN62368-1, ANSI/AAMI ES 60601-1, IEC60601-1, EN60601-1, CE & UKCA meets all applicable directives & legislation. **ECP60** ## ~~**Models and Ratings**~~ |Output<br>Power|Output 1|Output 1|Output 1|Output 2|Output 2|Output 2|Output 3|Output 3|Model Number| |---|---|---|---|---|---|---|---|---|---| ||Voltage|Current|Peak(1)|Voltage|Current|Peak(|1)<br>Voltage|Current|| |60 W|+5.0 VDC|7.0 A|9.1 A|+12.0 VDC|3.0 A|3.90|A||ECP60UD01| |60 W|+5.0 VDC|7.0 A|9.1 A|+15.0 VDC|2.0 A|2.60|A||ECP60UD02| |60 W|+5.0 VDC|7.0 A|9.1 A|+24.0 VDC|1.5 A|1.95|A||ECP60UD03| |60 W|+5.0 VDC|7.0 A|9.1 A|+15.0 VDC|2.0 A|2.60|A<br>-15.0 V|0.30 A|ECP60UT02| |60 W|+5.0 VDC|7.0 A|9.1 A|+24.0 VDC|1.5 A|1.95|A<br>-12.0 V|0.30 A|ECP60UT04| ## ~~**Notes**~~ _1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal._ ## ~~**Mechanical Details**~~ **==> picture [524 x 290] intentionally omitted <==** **----- Start of picture text -----**<br> 4.00 (101.6)<br>3.75 (95.2)<br>Voltage Adj.<br>CN1 - Input Connector<br>Pin 1 Neutral<br>Pin 2 Not Fitted 1<br>1 CN3<br>Pin 3 Line<br>CN2 6<br>Mates with JST housing 2.00<br>VHR-3N and JST Series (50.8) CN2<br>SVH-21T-P1.1 crimp terminals 6<br>1.75<br>1.75<br>Mounting holes marked with must be connected to safety earth CN1 3 (44.4) 1 (44.4)<br>1<br>CN2 Output Connector<br>UD/UT US05<br>0.13 ±0.01 (3.4 ±0.3)<br>UD/UT<br>Mounting hole need to be isolated from ground<br>Pin 1 V2<br>Pin 2 V1<br>Pin 3 V1<br>Pin 4 RTN<br>Pin 5 RTN 1.04 1.20<br>Pin 6 V3 (26.3) (30.4)<br>Mates with JST housing<br>VHR-6N and JST Series<br>SVH-21T-P1.1 crimp terminals<br>0.06 (1.6) 0.1 (2.5)<br>**----- End of picture text -----**<br> ## ~~**Notes**~~ 1. All dimensions are in inches (mm). 3. Tolerance: ±0.02 (±0.5) unless stated 2. Weight: 0.34 lbs (155 g) approx. ## ~~**Derating Curve**~~ **==> picture [230 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>40<br>20<br>0<br>-20 -10 0 10 20 30 40 50 60 70 80<br>Ambient Temperature (ºC)<br>Output Power (%)<br>**----- End of picture text -----**<br> 05 Feb 2024
Updated at February 9, 2023
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →