ECP130PS48
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 130W @ 10CFM, 100 W
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):100W; Power Rating (Forced Cooling):130W @ 10CFM; Input Voltage VAC:85V AC to 264V AC; Power Supply Output Type:Fixed; O
- SVHC: No SVHC (15-Jan-2018)
- Product Range: ECP130 Series
- No. of Outputs: 1 Output
- Output Power Max: 100W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.08A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): 130W @ 10CFM
- Power Rating (Convection Cooling): 100W
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 52.03 € |
| Current stock | 10+ |
| Lead time | 30 days |
ECP130 series ## 130W **Fancooled** 100W **Convection cooled** **AC-DC power supplies** The ECP130 series is designed to minimize the no load power consumption and maximize efficiency to facilitate equipment design to meet the latest environmental legislation. Approved for medical (2 x MOPP), industrial electronics and ITE applications. The power supply contains two fuses and a low leakage current as required for medical applications, it is safety approved to operate in a 70°C ambient. The low profile and safety approvals covering ITE and medical standards along with conducted emissions to EN55011/32 level B allow the versatile ECP130 series to be used in a vast range of applications. **==> picture [276 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> Features Applications<br>ar<br>Instrumentation Robotics IoT<br>@<br>Process control<br>**----- End of picture text -----**<br> - f 130W fan cooled 100W convection cooled - f 76.2 x 50.8mm (3” x 2”) footprint, 28.0mm profile - f Regulated single outputs 12 to 48VDC - f Input range 85 to 264VAC - f High efficiency – up to 95% - f Medical (2 x MOPP) & ITE approvals - f 4.0kVAC input to output isolation ## **Dimensions** 76.2 x 50.8 x 28.0mm (3.00” x 2.00” x 1.10”) **==> picture [154 x 76] intentionally omitted <==** **----- Start of picture text -----**<br> Documentation<br>[LT<br>Click the link or scan the code<br>- xppower.com<br>**----- End of picture text -----**<br> - f <0.5W no load input power - f -20°C to +70°C operating temperature - f Full load to +50°C - f 3 year warranty ## **Models & ratings** |Model number(1)|Output current|Output current|Output voltage|Efficiency(2)| |---|---|---|---|---| ||Convection-cooled|Forced Cooled (10CFM)||| |ECP130PS12|8.33 A|10.83A|12.0VDC|93%| |ECP130PS15|6.66 A|8.66A|15.0VDC|93%| |ECP130PS18|5.55 A|7.22A|18.0VDC|93%| |ECP130PS24|4.16 A|5.41A|24.0VDC|93%| |ECP130PS28|3.57 A|4.64A|28.0VDC|93%| |ECP130PS36|2.77 A|3.61A|36.0VDC|93%| |ECP130PS48|2.08 A|2.70A|48.0VDC|93%| Notes: 1. Add suffix ‘-S’ for input and output screw terminals e.g. ECP130PS24-S 2. Typical efficiency measured at full load and 230VAC input. 1 [| **AC-DC power supplies** ## ECP130 series ## **Input** **==> picture [554 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Input Voltage - Operating|80|115/230|264|VAC|Derate output from 100% at 90 VAC to 85% at 85 VAC| |Input Frequency|47|50/60|63|Hz|Agency approval, 47-63 Hz| |Power Factor|0.8||||230 VAC, 100% load EN61000-3-2 class A| |Input Current - Full Load||1.3/0.65||A|115/230 VAC| |Inrush Current||120||A|230 VAC cold start, 25°C| |Earth Leakage Current||20/40|50|µA|115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max)| |No load Input Power|||0.5|W|| |Input Protection|F3.15 A/250 V Internal fuse ftted in line and neutral.||||| ## **Output** |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Output Voltage|12||48|VDC|See models and ratings table| |Initial Set Accuracy|||±1|%|50% load, 115/230VAC| |Output Voltage Adjustment||||%|None| |Minimum Load|No minimum load required||||| |Start Up Delay|||2|s|115/230 VAC full load.| |Hold Up Time|10|15/11||ms|Min at full load, 115VAC. Typical at 100W/ 130W| |Drift|||±0.02|%|After 20 min warm up| |Line Regulation|||±0.5|%|90-264 VAC| |Load Regulation|||±0.5|%|0-100% load.| |Transient Response|||4|%|Recovery within 1% in less than 500µs for a 50-75% and 75-50% load<br>step| |Over/Undershoot|||7|%|Full load| |Ripple & Noise|||1|% pk-pk|<2% from no load to 10% load, <1% above 10% load. 20MHz bandwidth<br>and 10 µF electrolytic capacitator in parallel with 0.1µF ceramic<br>capacitator.| |Overvoltage Protection|110||140|%|Vnom, recycle input to reset| |Overload Protection|110||170|% I nom|| |Short Circuit Protection|||||Trip & Restart| |Temperature Coeffcient|||0.02|%/˚C|| ## **General** **==> picture [554 x 29] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>Efficiency 95 % 230 VAC (see fig. 1 & 2)<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Effciency||95||%|230 VAC (see fg. 1 & 2)| |Isolation: Input to output<br>Input to ground<br>Output to ground|4000|||VAC|2 x MOPP| ||1500|||VAC|1 x MOPP| ||500|||VDC|1 x MOPP| |Switching frequency|40||130|kHz|PFC| ||50||135||Main converter| |Power density|||1.2 (19.7)|W/cm3(W/in3)|Fan cooled| ||||0.92 (15.1)||Convection cooled| |MTBF||680||khrs|MIL-HDBK-217F at 25°C, GB| |Weight||115 (0.25)||g (lbs)|| Specifications subject to change without notice. 2 **AC-DC power supplies** ## ECP130 series ## **Environmental** **==> picture [553 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Operating temperature|-30||+70|°C|See derating curve, fg.3| |Storage temperature|-40||+85|°C|| |Cooling|10|||CFM|Forced-cooled >100W| |Humidity|5||95|%RH|Non-condensing| |Operating altitude|||5000|m|| |Shock|±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27||||| |Vibration|Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6||||| ## **Emissions - EMC** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Notes & conditons| |---|---|---|---| ||||| |Conducted|EN55011/32|Class B|| |Radiated|EN55011/32|Class A|Class B with additional KINGCORE K5B RC<br>20 x 30 x 5 - MB ferrite on input cable. L & N require 2 turns and earth<br>cable 1 turn.| |Harmonic current|EN61000-3-2|Class A|| |Voltage ficker|EN61000-3-3||| ## **Immunity - EMC** |Phenomenon|Standard|Test Level|Criteria|Notes & conditons| |---|---|---|---|---| |Medical device EMC|IEC60601-1-2|3|as below|| |Low voltage PSU EMC|EN61204-3|3|as below|| |ESD|EN61000-4-2|3|A|| |Radiated|EN61000-4-3||A|| |EFT|EN61000-4-4|3|A|| |Surge|EN61000-4-5|30% for 10ms|A|| |Conducted|EN61000-4-6|Conducted|A|| |Magnetic felds|EN61000-4-8|Magnetic Fields|A|| |Dips and interruptions|EN55035 (100 VAC)|Dip >95% (0 VAC), 8.3ms|A|| |||Dip 30% (70 VAC), 416ms|A|| |||Dip >95% (0 VAC), 4160ms|B|| ||EN55035 (240 VAC)|Dip >95% (0 VAC), 10.0ms|A|| |||Dip 30% (168 VAC), 500ms|A|| |||Dip >95% (0 VAC), 5000ms|B|| ||EN60601-1-2<br>(100 VAC)|Dip 100% (0 VAC), 10.0ms|A|| |||Dip 100% (0 VAC), 20ms|A|| |||Dip 60% (40 VAC), 100ms|B|Performance criteria A <25 W| |||Dip 30% (70 VAC), 500ms|A|| |||Dip 100% (0 VAC), 5000ms|B|| ||EN60601-1-2<br>(240 VAC)|Dip 100% (0 VAC), 10.0ms|A|| |||Dip 100% (0 VAC), 20ms|A|| |||Dip 60% (96 VAC), 100ms|A|| |||Dip 30% (168 VAC), 500ms|A|| |||Dip 100% (0 VAC), 5000ms|B|| Specifications subject to change without notice. 3 **AC-DC power supplies** ## ECP130 series ## **Safety approvals** |Certfcaton|Standard|Notes & Ccnditons| |---|---|---| |CB|IEC62368-1|Information technology| ||IEC60601-1 Ed 3.1 Including Risk Management|Medical| |UL|CSA 22.2 No.62368-1-11 Ed 2, UL62368-1|Information technology| ||ANSI/AAMI ES60601-1: & CSA C22.2 No.6061-1:08|Medical| |EN|EN62368-1|Information technology| ||EN60601-1|Medical| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| |||| |Isolaton|Standard|Notes & Ccnditons| |Primary to Secondary|2 x MOPP (Means of Patient Protection)|IEC60601-1 Ed 3.1| |Primary to Earth|1 x MOPP (Means of Patient Protection)|| |Secondary to Earth|1 x MOPP (Means of Patient Protection)|| ## **Application notes** ## Thermal considerations In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). See mechanical details for component locations. |Temperature measurements (at maximum ambient)|Temperature measurements (at maximum ambient)| |---|---| |Component|Max temperature (°C)| |TR1 Coil|120°C| |L4 Coil|120°C| |C2|105°C| |C50|105°C| ## Service life The estimated service life of the ECP225-A is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor with in the product when installed by the end application. The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature. Estimate service life vs component temperature **==> picture [209 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> 80000<br>70000<br>60000<br>50000<br>C2 & C50<br>40000<br>30000<br>20000<br>10000<br>0<br>105 95 85 75 65<br>C2 + C52 Temperature (ºC)<br>Lifetime (Hrs)<br>**----- End of picture text -----**<br> Specifications subject to change without notice. 4 **AC-DC power supplies** ## ECP130 series ## **Efficiency vs load** ## Figure 1, ECP130PS12, 12 V at 130 W ## Figure 2, ECP130PS24, 24 V at 130 W **==> picture [548 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> 100% 100%<br>95% 95%<br>90% 90%<br>115Vac input<br>85% Convection-Cooled Forced-Cooled 85% Convection-Cooled Forced-Cooled 230Vac input<br>80% 80%<br>75% 75%<br>70% 70%<br>10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100<br>Load (%) Load (%)<br>Efficiency Efficiency<br>**----- End of picture text -----**<br> ## **Mechanical details** **==> picture [319 x 424] intentionally omitted <==** **----- Start of picture text -----**<br> 76.2 (3.00)<br>69.9 (2.75)<br>L4<br>1<br>CN2<br>44.5<br>(1.75) 4<br>3 C50<br>CN1<br>1 TR1<br>C2<br>2.4 (0.094)<br>CN1 - Input Connector CN2 - Output Connector<br>Pin 1 Neutral Pin 1 +Vout<br>Pin 2 Not Fitted Pin 2 +Vout<br>Pin 3 Line Pin 3 Com<br>Pin 4 Com<br>Mates with JST housing<br>VHR-3N and JST Series Mates with JST housing<br>SVH-21T-P1.1 crimp terminals VHR-4N and JST Series<br>SVH-21T-P1.1 crimp terminals<br>Mounting hole marked with<br> must be connected to safety earth<br>3.4 (0.13)<br>3.4 (0.13)<br>50.8 (2.00)<br>23.8 (0.937)<br>1.6 (0.063)<br>**----- End of picture text -----**<br> Notes: 1. All dimensions in mm (inches). Tolerance .xx = 0.50 (±0.02); .xxx = 0.25 (±0.01) 2. Weight: 115g (0.0.25lbs) Specifications subject to change without notice29 May 2025 . **5**
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →