ECF40US36
AC/DC Open Frame Power Supply (PSU), ITE & Medical, 1 Output, 40 W, 80V AC to 264V AC
- Manufacturer: XP POWER
- Product type: AC / DC Open Frame Power Supplies
- No. of Outputs:1 Output; Power Rating (Covection Cooling):40W; Power Rating (Forced Cooling):-; Input Voltage VAC:80V AC to 264V AC; Power Supply Output Type:Adjustable, Fixed; Output Vol
- SVHC: No SVHC (15-Jan-2018)
- Product Range: ECF40 Series
- No. of Outputs: 1 Output
- Output Power Max: 40W
- Input Voltage VAC: 80V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 80V
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 1.11A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 36VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Medical
- Power Rating (Forced Cooling): -
- Power Rating (Convection Cooling): 40W
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 21.1 € |
| Current stock | 10+ |
| Lead time | 30 days |
ECF40 series ## 40W **Convectioncooled** **AC-DC power supplies** The ECF40 series is designed to minimize the no load power consumption and maximize efficiency to facilitate equipment design to meet the latest environmental legislation. Approved for medical (2 x MOPP) and ITE applications in either Class I or Class II installations and has two AC line fuses and low leakage currents required by medical applications. This range of single output AC-DC power supplies are packaged in a low profile 28.0mm height with a foot print of just 76.2 x 38.1mm. The ECF40 provides up to 40W convection-cooled over the full 90-264VAC input range, and operates down to 80VAC with minimal de-rating. The low profile, low noise and safety approvals covering ITE and medical standards allows the versatile series to be used in a wide range of applications. **==> picture [271 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> Features Applications<br>ge<br>Instrumentation Robotics IoT<br>ez @<br>Healthcare Process control<br>**----- End of picture text -----**<br> - f 40W convection cooled - f 76.2 x 38.1mm (3” x 1.5”) footprint, 28.0mm profile - f Regulated single outputs 12 to 48VDC - f Input range 80 to 264VAC - f Medical (2 x MOPP) & ITE approvals - f Class I & Class II installations ## **Dimensions** 76.2 x 38.1 x 28.0mm (3.00” x 1.50” x 1.10”) **==> picture [74 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Documentation<br>**----- End of picture text -----**<br> **==> picture [136 x 46] intentionally omitted <==** **----- Start of picture text -----**<br> For further information click the link or scan<br>the code<br>: xppower.com<br>**----- End of picture text -----**<br> - f Less than 0.15W no load input power - f 3 year warranty ## **Models & ratings** |Model number(2)|Output voltage|Output current|Efficiency|Output power| |---|---|---|---|---| |ECF40US12|12.0VDC|3.34A|91%|40W| |ECF40US15|15.0VDC|2.67A|92%|40W| |ECF40US18|18.0VDC|2.23A|93%|40W| |ECF40US24|24.0VDC|1.67A|91%|40W| |ECF40US36|36.0VDC|1.11A|90%|40W| |ECF40US48|48.0VDC|0.83A|90%|40W| Notes: 1. Typical efficiency measured at full load and 230VAC input. 1 [| **AC-DC power supplies** ## ECF40 series ## **Input** **==> picture [554 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Input voltage range|80|115/230|264|VAC|Derate output from 100% at 90VAC to 90% at 85VAC and 80% at 80VAC| |Input frequency|47|50/60|63|Hz|Agency approval, 47-63Hz| |No load input power|||0.15|W|| |Inrush current|||70|A|264VAC cold start, 25°C| |Earth leakage current|||250|µA|264VAC/60Hz| |Input protection|T3.15A/250A, 250V Internal fuse ftted in line and neutral.||||| |Power factor|EN61000-3-2 Class A||||| ## **Output** |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| |Output voltage|12||48|48|See models and ratings| |Initial set accuracy|||±1|%|50% load, 115/230VAC| |Output voltage adjustment|10||||| |Minimum load|No minimum load required||||| |Line regulation|||±0.5|%|90-264VAC| |Load regulation|||1||0-100% load.| |Start up delay||1|2|s|| |Start up rise time||50||ms|| |Hold up time|8.3/20||||At full load and 115VAC| |Transient response|||4|%|Recovery within 1% in less than 500µs for a 50-75% and 75-50% load<br>step| |Ripple & noise|||3/2|% pk-pk|12V/15-48V models| |Overvoltage protection|115||140|% Vnom|Vnom, recycle input to reset| |Overload protection|140||160|%|Of total power| |Over/undershoot|||5|%/°C|| |Short circuit protection|Continuous trip & restart (hiccup mode)||||| |Temperature coeffcient|||0.05|%/°C|| ## **General** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & Conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| ||||||| |Effciency|See models & ratings||||| |Isolation|4000|||VAC|Input to output (2 MOPP)| ||1500||||Input to ground (1 MOPP)| ||500||||Output to ground (1 MOPP at output voltage)| |Switching frequency||||kHz|| |Power density|||0.4 (8.1)|W/cm3(W/in3)|PCB mount version| |Mean time between failure|500|||khrs|MIL-HDBK-217F, Notice 2 +25°C GB| |Weight||69.0 (0.15)||g (lbs)|| Specifications subject to change without notice. 2 **AC-DC power supplies** ## ECF40 series ## **Environmental** **==> picture [553 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Operating temperature|-20||+70|°C|See derating curve| |Storage temperature|-40||+85|°C|| |Cooling|Convection-cooled||||| |Humidity|||95|%RH|Non-condensing| |Operating altitude|||5000/4000|m|ITE/Medical| |Shock|±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (±0.5msecs), half sine. Conforms to EN60068-2-27||||| |Vibration|Single axis 10-500Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6||||| ## **Emissions - EMC** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Notes & conditons| |---|---|---|---| ||||| |Conducted|EN55011/32|Class B|| |Radiated|EN55011/32|Class A|| |Harmonic current|EN61000-3-2|Class A|| |Voltage ficker|EN61000-3-3||| ## **Safety approvals** |Certfcaton|Standard|Notes & conditons| |---|---|---| |CB|IEC60950-1, IEC62368-1|Information technology| ||IEC60601-1 Ed 3.1 Including Risk Management|Medical| |UL|UL62368-1 2nd Ed., CSA C22.2 No. 62368-1-14|Information technology| ||ANSI/AAMI ES60601-1: & CSA C22.2 No.6061-1:08|Medical| |EN|EN62368-1|Information technology| ||EN60601-1|Medical| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| Specifications subject to change without notice. 3 **AC-DC power supplies** ## ECF40 series ## **Emissions - Immunity** **==> picture [554 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Criteria|Notes & conditons| |---|---|---|---|---| |||||| |Medical device EMC|IEC60601-1-2|Ed.4.0 : 2014|as below|| |Low voltage PSU EMC|EN61204-3|High severity level|as below|| |ESD|EN61000-4-2|±8kV contact, ±15kV air|A|| |Radiated|EN61000-4-3|3|A|| |EFT|EN61000-4-4|3|A|| |Surge|EN61000-4-5|Installation class 3|A|| |Conducted|EN61000-4-6|3|A|| |Magnetic felds|EN61000-4-8|4|A|| |Dips and interruptions|EN61000-4-11 (100VAC)|Dip 100% (0VAC), 8.4ms|A|25% derating| |||Dip 100% (0VAC), 16.7ms|B|| |||Dip 60% (40VAC), 200ms|B|| |||Dip 30% (70VAC), 500ms|B|| |||Dip 20% (80VAC), 5000ms|B|| |||Int 100% (0VAC), 5000ms|B|| ||EN61000-4-11 (115VAC)|Dip 100% (0VAC), 8.4ms|A|| |||Dip 100% (0VAC), 16.7ms|B|| |||Dip 60% (40VAC), 200ms|B|| |||Dip 30% (70VAC), 500ms|B|| |||Dip 20% (80VAC), 5000ms|B|| |||Int 100% (0VAC), 5000ms|B|| ||EN61000-4-11 (240VAC)|Dip 100% (0VAC), 10ms|A|| |||Dip 100% (0VAC), 20ms|B|| |||Dip 60% (96VAC), 200ms|B|| |||Dip 30% (168VAC), 500ms|B|| |||Dip 20% (192VAC), 5000ms|B|| |||Int 100% (0VAC), 5000ms|B|| ||EN60601-1-2 (100VAC)|Dip 100% (0VAC), 10ms|A|30% derating| |||Dip 100% (0VAC), 20ms|A|60% derating| |||Dip 60% (40VAC), 100ms|A|75% derating| |||Dip 30% (70VAC), 500ms|A|| |||Int 100% (0VAC), 5000ms|B|| ||EN60601-1-2 (240VAC)|Dip 100% (0VAC), 10ms|A|| |||Dip 100% (0VAC), 20ms|A|| |||Dip 60% (96VAC), 100ms|A|| |||Dip 30% (168VAC), 500ms|A|| |||Int 100% (0VAC), 5000ms|B|| Specifications subject to change without notice. 4 **AC-DC power supplies** ## ECF40 series ## **Application notes** Efficiency vs load ## ECF40US12 **==> picture [207 x 258] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>95<br>90<br>85<br>80<br>75<br>70<br>25 50 75 100<br>Load (%)<br>Temperature derating curve<br>100<br>50<br>0<br>-25 -20 0 +50 +70<br>Ambient Temperature (ºC)<br>Efficiency (%)<br>Output Load (%) may not be met<br>Some specification parameters<br>**----- End of picture text -----**<br> Temperature derating curve ## ECF40US24 **==> picture [288 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>95<br>90 115VAC<br>85 230VAC<br>80<br>75<br>70<br>25 50 75 100<br>Load (%)<br>Efficiency (%)<br>**----- End of picture text -----**<br> Thermal considerations In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using thermocouples placed on the hottest part of the component (out of direct air flow). See mechanical details for component locations. |Temperature measurements (at maximum ambient)|Temperature measurements (at maximum ambient)| |---|---| |Component|Max temperature (°C)| |TR1 coil|120°C| |L1 coil|120°C| |C2|105°C| |C13|105°C| |C14|105°C| Specifications subject to change without notice. 5 **AC-DC power supplies** ## ECF40 series ## **Application notes** ## Service life The estimated service life of the ECF40 is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of key capacitors with in the product when installed by the end application. The graph below expresses the estimated lifetime based on the temperature of these key components based on the average temperature over the lifetime of the equipment. Estimate service life vs component temperature **==> picture [554 x 444] intentionally omitted <==** **----- Start of picture text -----**<br> 80000<br>70000<br>60000<br>50000<br>C2<br>40000<br>C13 & 14<br>30000<br>20000<br>10000<br>0<br>105 95 85 75 65<br>C2 + C52 Temperature (ºC)<br>Mechanical details<br>Output Voltage Control<br> 76.2 (3.00) Ø3.6 (0.14) through in 4 posi�ons<br>L1<br>C2 C13 -VE Output<br>Line +VE Terminals<br>C14<br>Neutral<br>TR1<br>3.18 3.18 69.85 (2.75)<br>(0.13) (0.13)<br>CN1 - input connector CN1 - input connector<br>Pin 1 Neutral 28.14 Pin 1 -Vout<br>Pin 2 Not fitted (1.11) Pin 2 +Vout<br>Pin 3 Line Mates with JST housing VHR-3N<br>Mates with JST housing VHR-3N and and JST Series SVH-21T-P1.1<br>JST Series SVH-21T-P1.1 crimp terminals crimp terminals<br>Lifetime (Hrs)<br>1.5) 1.25)<br> ( (<br> 38.1 31.57<br>**----- End of picture text -----**<br> Mounting hole marked with must be connected to safety earth for class I applications ## Notes: 1. All dimensions in mm (inches). 2. Weight: 66g (0.14lb) 28 July 2025 **6**
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →