ECE80US12
AC/DC PCB Mount Power Supply (PSU), ITE, 1 Output, 80 W, 12 VDC, 6.67 A
- Manufacturer: XP POWER
- Product type: AC / DC PCB Mount Power Supplies
- No. of Outputs:1 Output; Output Power Max:80W; Output Voltage - Output 1:12V; Output Current - Output 1:6.67A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage - O
- SVHC: No SVHC (15-Jan-2018)
- Depth: 91.4mm
- Width: 45.72mm
- Height: 28mm
- Product Range: ECE80 Series
- No. of Outputs: 1 Output
- Output Power Max: 80W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264V
- Input Voltage AC Min: 85V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 6.67A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 66.63 € |
| Current stock | 10+ |
| Lead time | 30 days |
ECE80 series ## 80W **Convectioncooled** **AC-DC power supplies** The ECE80 series as standard is an encapsulated PCB mount device, it can also be supplied in an encapsulated chassis mount package with screw terminals (-S option), also available with a DIN rail mounting (-SD option). With approvals to world-wide safety standards, compliance with class B for conducted & radiated emissions and a 20%, 30s peak load capability. Not requiring any external components, these class II isolation parts benefit system designers with easy integration into a wide range of applications. **==> picture [333 x 122] intentionally omitted <==** **----- Start of picture text -----**<br> Features Applications<br>f 80W convection cooled<br>ge<br>f Regulated single outputs 12 to 48VDC Instrumentation Robotics IoT<br>f Input range 85 to 264VAC<br>f Encapsulated PCB or chassis/DIN rail mount package<br>f Peak load capability<br>Process control<br>®<br>**----- End of picture text -----**<br> - f 4.0kVAC input to output isolation - f No external components required ## **Dimensions** ECE80 91.4 x 45.72 x 28.0mm (3.60 x 1.80 x 1.10”) ECE80-S 113.0 x 47.5 x 28.5mm (4.45 x 1.87 x 1.12) **Documentation** Lo For further information click the link or scan the code - f -25°C to +70°C operating temperature - f Full load to +50°C **==> picture [61 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> xppower.com<br>**----- End of picture text -----**<br> - f 3 year warranty ## **Models & ratings** |Model number(2,3)|Output voltage|Output current|Output current|Efficiency(4)|Output power| |---|---|---|---|---|---| |||Nominal|Peak(1)||| |ECE80US12|12.0VDC|6.67A|8.67A|88%|80W| |ECE80US15|15.0VDC|5.33A|6.93A|88%|80W| |ECE80US24|24.0VDC|3.33A|4.33A|87%|80W| |ECE80US36|36.0VDC|2.22A|2.89A|87%|80W| |ECE80US48|48.0VDC|1.67A|2.17A|87%|80W| ## Notes: 1. Peak load lasting <30s with a maximum duty cycle of 10%, average output power not to exceed nominal power. 2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE80US12-S. 3. A screw terminal version (-S) is available with DIN Clip attached. Add suffix ‘D’, e.g. ECE80US24-SD. DIN Rail mounting clip is available as a separate item, order code ECE80 DIN CLIP. 4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230VAC input. 1 [| **AC-DC power supplies** ## ECE80 series ## **Input** **==> picture [554 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Input voltage range|85||264|VAC|Derate load from 100% at 90VAC to 90% at 85VAC| |Input frequency|47||63|Hz|| |Power factor|||||EN61000-3-2 class A compliant| |Input current||1.4/0.87||A rms|At 115/230VAC| |No load input power|||0.3|W|12-36VAC versions| ||||0.5||48VAC versions| |Inrush current||60/120||A|115/230VAC cold start at +25°C| |Earth leakage current|||||Class II construction no earth| |Input protection|Internal T2A/250 VAC fuse||||| ## **Output** **==> picture [554 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Output voltage|12||48|VDC|See models and ratings table| |Initial set accuracy|||1|%|| |Minimum load|No minimum load required||||| |Start Up Delay|||0.6|s|| |Start Up Rise Time|||30|ms|| |Hold up time|8.4|15||ms|At full load and 115VAC| |Line regulation|||±0.5|%|| |Load regulation|||±1|%|ECE80US03/05-S| |Transient response|||4|%|Recovery within 1% in less than 500µs for a 25% load change| |Ripple & noise|||1|% pk-pk|ECE80 models, 20MHz bandwidth| ||||2||ECE80-S models, 20MHz bandwidth| |Overvoltage protection|115||140|% Vnom|ECE80US03 models| |Overload protection|110||185|%|| |Short circuit protection|Trip & restart (hiccup mode)||||| |Temperature coeffcient|||0.02|%/°C|| ## **General** |Characteristc|Minimum|Typical|Maximum|Units|Notes & Conditons| |---|---|---|---|---|---| |Effciency|86|87|88|%|See models and ratings table| |Isolation: input to output|3000|||VAC|Input to output| |Switching frequency||65||kHz|| |Power density|||0.68 (11.2)|W/cm3(W/in3)|| |Mean time between failure||>300||khrs|MIL-HDBK-217F, +25°C GB| |Weight||260 (0.57)||g (lbs)|ECE80| |||280 (0.62)|||ECE80-S| Specifications subject to change without notice. 2 **AC-DC power supplies** ## ECE80 series ## **Environmental** **==> picture [553 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Minimum Typical Maximum Units Notes & conditions<br>**----- End of picture text -----**<br> |Characteristc|Minimum|Typical|Maximum|Units|Notes & conditons| |---|---|---|---|---|---| ||||||| |Operating temperature|-40||+70|°C|Some specifcation parameters may not met below -25°C. Derate linearly<br>from 100% load at +50°C to 50% load at +70°C.| |Storage temperature|-40||+85|°C|| |Cooling|Convection-cooled||||| |Humidity|||95|%RH|Non-condensing| |Operating altitude|||5000|m|| |Vibration|2g, 10Hz to 500Hz, 10 mins/cycle, 60 mins each cycle||||| ## **Emissions - EMC** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test level Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test level|Notes & conditons| |---|---|---|---| ||||| |Conducted|EN55032|Class B|| |Radiated|EN55032|Class B|| |Harmonic current|EN61000-3-2||| |Voltage ficker|EN61000-3-3||| ## **Emissions - Immunity** **==> picture [554 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> Phenomenon Standard Test Level Criteria Notes & conditions<br>**----- End of picture text -----**<br> |Phenomenon|Standard|Test Level|Criteria|Notes & conditons| |---|---|---|---|---| |||||| |ESD immunity|EN61000-4-2|±6kV/±8kV|A|Contact/air discharge| |Radiated immunity|EN61000-4-3|10 V/m, 80% mod|A|| |EFT/burst|EN61000-4-4|3|A|| |Surge|EN61000-4-5|2|A|| |Conducted|EN61000-4-6|3|A|| |Magnetic felds|EN61000-4-8|3||| |Dips and interruptions|EN61000-4-11|>95% for 10ms|A|DIP (100VAC and 230VAC)| |||30% for 500ms|A|DIP (100VAC and 230VAC)| |||>95% for 5000ms|B|INT(100VAC and 230VAC)| ## **Safety approvals** |Certfcaton|Standard|Notes & Ccnditons| |---|---|---| |CB|IEC62368-1, IEC60950-1|| |UL|UL62368-1, UL60950-1, CSA 22.2 No.234 per cUL|| |EN|EN60950-1|| |CE|Meets all applicable directives|| |UKCA|Meets all applicable legislation|| Specifications subject to change without notice. 3 **AC-DC power supplies** ## ECE80 series ## **Mechanical details** Encapsulated (-E) Screw terminal (-S) **==> picture [379 x 581] intentionally omitted <==** **----- Start of picture text -----**<br> ( )<br> 3.54 (0.139) (0.50)<br>ACN<br>+Vo<br>45.7 30.0<br>(1.80) (1.18) TOP VIEW -Vo<br>7.8<br>(0.31)<br>ACL<br>3.55 84.3 (3.32)<br>(0.14)<br>28.0<br>(1.10)<br>4 x ø1.5 (ø0.06)<br> 10.2 (0.4)<br> 4.5 (0.18) 104.0 (4.09) 4 x ø3.5<br>(4 x ø0.14)<br>11.2<br>(0.44)<br>+Vo<br>ACN TOP VIEW 21.3<br>47.5 ACL (0.84) 38.1<br>(1.87) -Vo<br>(1.50)<br> 89.7 (3.50)<br>4.7<br>(0.20)<br>13.8 (0.54) 1º<br>28.5<br>(1.12)<br>113.0 (4.45)<br>6.2 2.5<br>(0.24) (0.10)<br>Op�onal 14.73<br>DIN clip<br>(0.58)<br> 35.0 (1.38)<br>**----- End of picture text -----**<br> Notes: 1. All dimensions in mm (inches). 2. Weight: ECE80: 260g (0.57lbs) ECE80-S: 280g (0.62lbs) 3. Tolerances: x.xx (x.x) = ±0.5 (±0.02). x.xxx (x.xx) = ±0.25 (±0.01) 25 June 2025 **4**
Updated at June 8, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →