Image not available
Illustrative purposes only
EA05TML3AN
DELAY AND TIMING RELAYS EA05TML3AN IN
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type: Signal Relays
- SVHC: No SVHC (21-Jan-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 109.45 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Monitoring Relays AC Current Transformer Type E 83-20-50** - **7 input ranges in one unit: 0 - 5 AAC** - **0 - 10 AAC 0 - 15 AAC 0 - 20 AAC** **0 - 25 AAC** - **0 - 30 AAC** - **0 - 50 AAC** - **Output 4-20 mADC** - **Easy interface to PLC or setpoint relays** - **For mounting on DIN-rail in accordance with DIN/EN 50 022** - **22.5 mm small Euronorm housing** ## **Product Descri tion p** Small AC current metering transformer with 7 knob selectable ranges. Output from the transformer is 4-20 mADC in accordance with IEC 60381-1. Can be used with relays DIB01, PIB01, DIC01 or PIC01 or directly connected to a PLC. Power supply ON is indicated by a green LED. 12 mm hole for isolated current carrying wire makes it suitable for most applications. For mounting on DINrail or directly on surface by screws. ## **Orderin Ke g y** **Type Output Input current (highest range)** ## **E 83-20 50** ## **T e Selection yp** |**Input current**|**Output current**|**Switch position**|**Type no.**| |---|---|---|---| |0- 5 AAC|4 - 20 mA|5|**E83-20 50**| |0-10 AAC|4 - 20 mA|10|**E83-20 50**| |0-15 AAC|4 - 20 mA|15|**E83-20 50**| |0-20 AAC|4 - 20 mA|20|**E83-20 50**| |0-25 AAC|4 - 20 mA|25|**E83-20 50**| |0-30 AAC|4 - 20 mA|30|**E83-20 50**| |0-50 AAC|4 - 20 mA|50|**E83-20 50**| ## **Input Specifications** |**Current range**|0 - 5 AAC|0 - 10 AAC|0 - 15 AAC|0 - 20 AAC| |---|---|---|---|---| |**Max. current** (continuously)|100 AAC|100 AAC|100 AAC|100 AAC| |**Max. overload current**(t = 30 s)|300 AAC|300 AAC|300 AAC|300 AAC| |**Overvoltage category**|III(IEC 60664)|III(IEC 60664)|III(IEC 60664)|III(IEC 60664)| |**Frequency range**|40 Hz - 1 kHz|40 Hz - 1 kHz|40 Hz - 1 kHz|40 Hz - 1 kHz| |**Current range**|0 - 25 AAC|0 - 30 AAC|0 - 50 AAC|| |**Max. current** (continuously)|100 AAC|100 AAC|100 AAC|| |**Max. overload current**(t = 30 s)|300 AAC|300 AAC|300 AAC|| |**Overvoltage category**|III(IEC 60664)|III(IEC 60664)|III(IEC 60664)|| |**Frequency range**|40 Hz - 1 kHz|40 Hz - 1 kHz|40 Hz - 1 kHz|| **1** Specifications are subject to change without notice (12.09.07) **E 83-20-50** ## **Out ut S ecifications p p** |**Output current**(sink)|4-20 mADC| |---|---| |**Maximum output current**|30 mADC| |**Tolerance of output current**|| |@ 50 Hz|± 2%| |**Temperature variation**<br>**Frequency variation**<br>**Power supply**(loop voltage)|± 400ppm/°C<br>10ppm/Hz<br>10-40 VDC| ## **General S ecifications p** |**Power ON delay**|< 2 s| |---|---| |**Reaction time**|T < 200 ms| |**Indication for**|| |Power supplyON|LED, green| |**Environment**|| |Degree of protection|IP 20| |Pollution degree|3| |Operatingtemperature|-20° to +50°C(-4° to +122°F)| |**Housing**|| |Dimensions|22.5 x 56 x 49 mm| |Material|ABS| |**Weight**|70g| |**Approval**|UL| |**CE Marking**|Yes| |**EMC**|Electromagnetic Compatibility| |Immunity|According toEN 61000-6-1| ||(tolerance of output current:| ||± 2%)| ||According toEN 61000-6-2| ||(tolerance of output current:| ||± 5%)| |Emission|According toEN 61000-6-3| ## **Mode of Operation** The E 83-20 is a small AC current metering transformer with standardized 4-20 mADC output. This makes it very useful as an AC current interface to a PLC with 4-20 mADC input. or more setpoints can monitor the current and signal alarm. In the 5 A range the E 83-20 is often used as a 4-20 mADC signal converter for larger standard AC current transformers with 5 AAC secondary output. Used with relays DIB01, PIB01, DIC01 or PIC01, one ## **Input/Output Curve** **==> picture [244 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> Output<br>(mADC)<br>20<br>16<br>12<br>8<br>4<br>Input<br>50 100 (% of range)<br>**----- End of picture text -----**<br> The metered conductor is drawn through the central hole of the current metering transformer. It is possible to measure currents below the nominal range by drawing the conductor through the hole several times. If the conductor is drawn through the central hole e.g. 5 times, the transformer will register 5 AAC when the current in the conductor is 1 AAC. ## **Resistance/Voltage Curve** **==> picture [190 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> Max. R load ( Ω )<br>(V)<br>Loop voltage<br>**----- End of picture text -----**<br> **Max. load resistance versus loop voltage** **2** Specifications are subject to change without notice (12.09.07) **E 83-20-50** ## **Wiring Diagram** ## **Dimensions** **==> picture [288 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>I ~ ⁄⁄ I<br>2 Ø<br>i<br>R load<br>ø<br>**----- End of picture text -----**<br> **3** Specifications are subject to change without notice (12.09.07)
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →