E58-CIFQ2-E
USB Communication Cable, Temperature Controller
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Controller Accessories
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 55.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **E5_C TEMPERATURE CONTROLLER** H i g h p e r fo r m a n ce w i t h s i m p l i c i ty » Easy set-up and operation » High-contrast display » DIN-Track mounting type joined the lineup 2 ## The new standard in temperature control… _Omron has been an active innovator in temperature control since introducing its first temperature controller in 1967. Now temperature control has taken a giant leap forward with Omron’s next generation of controllers – the E5_C, which set new_ _global standards in the crucial areas of precision, user friendliness and control performance. The E5_C_ _series will save you time and effort in set-up and operation, while enabling faster and more accurate_ ## **Key features** - High-contrast, white LCD display visible from large distances and from any angle - Easy to set up, and operate intuitively via CX-Thermo without power supply - 50 ms sampling period for fast and precise regulation - Functions for diagnosis for secure operations (see note 1) - Useful timer and logic operation functions eliminating the need of a PLC _monitoring/control of your process. The highvisibility display of the new series is also extremely easy to read and virtually eliminates any possibility for human error._ **==> picture [138 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> NEW GENERATION<br>@ ’<br> Note 1: Alarm for loop break or PV change rate, heater<br>burnout or sensor burnout detection<br>**----- End of picture text -----**<br> 3 ## …is higher in every respect ## **Clearer LCD display** The large, high-contrast, white LCD display contributes to the exceptional clarity and therefore readability of the E5_C series. The display can be read unambiguously from greater distances and from much wider viewing angles than normal. ## **Easy set-up and operation** Coupled with the autotuning algorithms, which greatly reduce set-up and commissioning time, Omron’s CX-Thermo support software has been specially developed for use with the E5_C series. This enables faster parameter set-up, easier device adjustment and simpler maintenance. ## **Unique performance** Although intrinsic high sampling speed and high precision are built into the E5_C series, Omron’s 2-PID control is a key factor behind the advantage it offers over standard controllers. Using a powerful algorithm, it makes all the difference to control stability and thus the quality of your products. 4 ## **High-contrast display** White LCD offers the greatest contrast to the black instrumentation backgrounds found in panels and the lighting conditions found in most control rooms. Despite the compact dimensions of the E5_C series, the use of white LCD technology means that the 15-25 mm display height gives maximum clarity for its size. The distance and viewing angle of the high-contrast, white LCD light display is also far less critical for viewers, ensuring correct readings every time.* * Excluding E5DC The white LCD display is easy to read in the subdued lighting conditions found in most control rooms. The display remains easy to read even from wide viewing angles. ## **Save space!** The compact and space-saving design of the new E5_C controller generation requires less panel depth (60 mm), allowing quick snap-mounting and easy installation even under very cramped conditions. Thanks to the IP66 protection of the front cover, the E5_C can withstand humid environments and also be cleaned with non-aggressive fluids.[*] > * Excluding E5DC 5 ## **Easy to connect, set-up and operate** The E5_C series is extremely easy to connect, set-up and operate in just a few simple steps using the instrument’s five front keys. Omron’s CX-Thermo software and new navigation assistant for intuitive settings offers the fastest possible parameter setting, easier device adjustment and simpler maintenance. ## **Ready to operate in only three steps:** Connect – no extra wiring necessary[*] Navigate and set-up Operate - CX-Thermo V4.6 must be preinstalled. It is available as a bundle together with USB converter E58-CIFQ2 and E58-CIFQ2-E ## **Time-saving ‘shift key’ for changing the set value** Key assignment can be changed for RUN/ STOP or AT execution/STOP according to the user’s setting! **==> picture [38 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Five front keys<br>**----- End of picture text -----**<br> **==> picture [189 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> Push the<br>shift key<br> Units digit setting Tens digit setting<br>**----- End of picture text -----**<br> 6 ## **The New E5DC with DIN-Track Mounting Capability Joins the E5_C Series, Next-generation Temperature Controllers. The E5DC Inherits the Features of the E5_C Series.** - Provides the unified design, operability, and functions of the E5_C Series. - Setup Tool Port on the front panel. - Width of 22.5 mm and mounts to DIN Track. - On-panel mounting is also possible. (Mounting Adapter required; sold separately.) **==> picture [176 x 32] intentionally omitted <==** **----- Start of picture text -----**<br> Removable Terminal Block for<br>Easy Mounting and Replacement.<br>**----- End of picture text -----**<br> **==> picture [154 x 26] intentionally omitted <==** **----- Start of picture text -----**<br> Removing from the Terminal Block<br>The image is for illustration purpose only.<br>* Hooks must be pressed to remove from the terminal block.<br>**----- End of picture text -----**<br> **==> picture [247 x 239] intentionally omitted <==** **----- Start of picture text -----**<br> E5DC — Life size<br>Ee<br>ou ay<br>any<br>96 mm<br>85 mm<br>K/<br>22.5 mm<br>**----- End of picture text -----**<br> 7 ## **Even Though the E5DC Mounts to DIN Track, the Same Displays and Same Settings as the Rest of the E5_C Series Make It Just as Easy to Use** You can make the following settings with the front-panel display and keys on the E5DC to reduce the workload: • Settings during machine commissioning • Easy confirmation of display:settings /process temperature when designing or evaluationg machines • Confirmation of settings when troubleshooting **==> picture [459 x 230] intentionally omitted <==** **----- Start of picture text -----**<br> < Previous In-panel Temperature Controllers > < E5DC ><br>HMI HMI<br>Any settings made from the<br>host can be easily confirmed<br>on the Temperature<br>Controller.<br>Temperature Temperature Controller: Temperature Easy confirmation if the<br>sensor with no displays or settings. sensor process temperature is<br>E5DC updated at the host.<br>with displays and settings:<br>You can confirm the<br>Support Software<br>process temperature at<br>Confirming Temperature Controller<br>the Temperature<br>status was not possible without Controller.<br>Support Software. —— oe<br>**----- End of picture text -----**<br> ## **Contributes to Machine Downsizing** The E5DC is only 22.5 mm wide and enables to install multi channel controls in limited space. The E5DC has a short body of only 85 mm in depth for easy mounting in control panels with 120-mm depths. **==> picture [152 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> Control panel<br>Previously<br>WV<br>E5DC<br>Requires<br>only half<br>the space.<br>**----- End of picture text -----**<br> **==> picture [156 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> 120 mm<br>,<br>107 mm<br>Previously<br>Previous Temperature<br>Controller Vv<br>E5DC<br>E5DC<br>Requires<br>85 mm only 85 mm<br>of depth.<br>**----- End of picture text -----**<br> 8 ## **Unique performance with simplicity…** ## **…and more control functionality** ## Extended inputs & outputs - Remote SP input With key features like simplicity in operation, Omron’s patented PID control, 50ms sampling period and the ability to handle multi-funtional input and output types, the E5_C sets a new standard in fast and precise temperature regulation. It has all the familiar functionality available from existing Omron temperature controllers to cover virtually any general-purpose demand. And naturally, the versatile E5_C series is available with input/output combinations to perfectly match all of your requirements. - Transfer output (voltage 1-5 V output) added - Event input - Auxiliary output ## New feature - Program-less communication - Position-proportional control 9 **EUROPE** LF. “a **AMERICA** **==> picture [65 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> CHINA<br> ASIA-PACIFIC<br>**----- End of picture text -----**<br> **JAPAN** ## **Global availability, support and network** ## **Providing you with the support you need to operate globally** ## Facts and figures - Over 35,000 employees - Almost 200 locations Whether you want to take your existing products into new industrial sectors, or whether you want to expand your business into entirely new geographical markets, Omron can help. We aim to offer the same level of support globally, without forgetting local needs. We have production facilities on every continent. Our smart communications network and seamless global support means we can provide you with parts and technical support wherever you sell your machines. And all of our components comply with major international standards, to ensure problem-free integration. It’s all there for you. - Presence in every continent - Knowledge-sharing through our global infrastructure - Local R&D facilities synchronised to local needs - Local factories to ensure quick response - Global pricing terms - Global support 10 ## **E5CC model list (all models 3 auxiliary outputs)** |**Output**|||**Option No.***<br>**Order code**<br>AC100-240V<br>**Order code**<br>AC/DC24V| |---|---|---|---| ||||E5CC-RX3A5M-000<br>E5CC-RX3D5M-000| ||||001<br>E5CC-RX3A5M-001<br>E5CC-RX3D5M-001| |**Out 1:**Relay|||003<br>E5CC-RX3A5M-003<br>E5CC-RX3D5M-003| |**Out 2:**non|||005<br>E5CC-RX3A5M-005<br>E5CC-RX3D5M-005| ||||006<br>E5CC-RX3A5M-006<br>E5CC-RX3D5M-006| ||||007<br>E5CC-RX3A5M-007<br>E5CC-RX3D5M-007| |**Out 1:**Voltage (pulse)<br>**Out 2:**non<br>003<br>001<br>005<br>006<br>007<br>E5CC-QX3A5M-006<br>E5CC-QX3D5M-006<br>E5CC-QX3A5M-005<br>E5CC-QX3D5M-005<br>E5CC-QX3A5M-001<br>E5CC-QX3D5M-001<br>E5CC-QX3A5M-000<br>E5CC-QX3D5M-000<br>E5CC-QX3A5M-007<br>E5CC-QX3D5M-007<br>E5CC-QX3A5M-003<br>E5CC-QX3D5M-003<br>~~eS~~<br>~~aEe S=sS=~~<br>—~~__~~_~~_~~_-<br>_~~—_~~=~~.~~00<br>~~a~~<br>—#_—_ ~~wa~~<br>—~~_—~~_~~7~~?.<br>da~~s~~——|||| ||||E5CC-QQ3A5M-000<br>E5CC-QQ3D5M-000| ||||001<br>E5CC-QQ3A5M-001<br>E5CC-QQ3D5M-001| |**Out 1:**Voltage (pulse)|||003<br>E5CC-QQ3A5M-003<br>E5CC-QQ3D5M-003| |**Out 2:**Voltage<br>(pulse)|||005<br>E5CC-QQ3A5M-005<br>E5CC-QQ3D5M-005| ||||006<br>E5CC-QQ3A5M-006<br>E5CC-QQ3D5M-006| ||||007<br>E5CC-QQ3A5M-007<br>E5CC-QQ3D5M-007| |**Out 1:**Linear current<br>**Out 2:**non<br>004<br>005<br>006<br>007<br>E5CC-CX3A5M-005<br>E5CC-CX3D5M-005<br>E5CC-CX3A5M-004<br>E5CC-CX3D5M-004<br>E5CC-CX3A5M-007<br>E5CC-CX3D5M-007<br>E5CC-CX3A5M-006<br>E5CC-CX3D5M-006<br>E5CC-CX3A5M-000<br>E5CC-CX3D5M-000<br>~~SS~~<br>~~a~~<br>—#_—~~___ITs~~<br>—~~_~~—~~_?~~.<br>~~dT ——~~<br>——#_~~—__.~~<br>~~a~~|||| ||||E5CC-CQ3A5M-000<br>E5CC-CQ3D5M-000| |**Out 1:**Linear|||001<br>E5CC-CQ3A5M-001<br>E5CC-CQ3D5M-001| |current|||003<br>E5CC-CQ3A5M-003<br>E5CC-CQ3D5M-003| |**Out 2:**Voltage|||005<br>E5CC-CQ3A5M-005<br>E5CC-CQ3D5M-005| |(pulse)|||006<br>E5CC-CQ3A5M-006<br>E5CC-CQ3D5M-006| ||||007<br>E5CC-CQ3A5M-007<br>E5CC-CQ3D5M-007| As well as these models other models are available on request. Please contact the local sales office for special requests. *** Option No.: 001 003 004 005 006** Event Input 2, Communication Event Input 2, Event Input 4 Event Input 2, Heater Burnout SSR 3-phase heater Communication Transfer output defect detection alarm 11 ## **E5EC/E5AC Model list (all models 4 auxiliary outputs)** |**Output**|||**Option No.***<br>**Order code**<br>AC100-240V<br>**Order code**<br>AC/DC24V| |---|---|---|---| ||||E5_C-RX4A5M-000<br>E5_C-RX4D5M-000| |**Out 1:**Relay|||009<br>E5_C-RX4A5M-009<br>E5_C-RX4D5M-009| |**Out 2:**non|||010<br>011<br>E5_C-RX4A5M-010<br>E5_C-RX4D5M-010<br>E5_C-RX4A5M-011<br>E5_C-RX4D5M-011<br>~~_~~| |**Out 1:**Voltage (pulse)<br>**Out 2:**non<br>009<br>011<br>010<br>E5_C-QX4A5M-011<br>E5_C-QX4D5M-011<br>E5_C-QX4A5M-009<br>E5_C-QX4D5M-009<br>E5_C-QX4A5M-000<br>E5_C-QX4D5M-000<br>E5_C-QX4A5M-010<br>E5_C-QX4D5M-010<br>~~Eee~~<br>——~~—-~~<br>~~——~~-|||| ||||E5_C-RR4A5M-000<br>E5_C-RR4D5M-000| |**Out 1:**Relay|||009<br>E5_C-RR4A5M-009<br>E5_C-RR4D5M-009| |**Out 2:**Relay|||010<br>011<br>E5_C-RR4A5M-010<br>E5_C-RR4D5M-010<br>E5_C-RR4A5M-011<br>E5_C-RR4D5M-011<br>~~yw~~<br>~~.~~| |**Out 1:**Voltage (pulse)<br>**Out 2:**Voltage<br>(pulse)||009<br>011<br>010<br>E5_C-QQ4A5M-011<br>E5_C-QQ4D5M-011<br>E5_C-QQ4A5M-010<br>E5_C-QQ4D5M-010<br>E5_C-QQ4A5M-000<br>E5_C-QQ4D5M-000<br>E5_C-QR4A5M-000<br>E5_C-QR4D5M-000<br>E5_C-QQ4A5M-009<br>E5_C-QQ4D5M-009<br>~~EE EES~~<br>a<br>~~————-~~<br>——~~—-~~|| |**Out 1:**Voltage (pulse)|||009<br>E5_C-QR4A5M-009<br>E5_C-QR4D5M-009| |**Out 2:**Relay|||011<br>010<br>E5_C-QR4A5M-011<br>E5_C-QR4D5M-011<br>E5_C-QR4A5M-010<br>E5_C-QR4D5M-010<br>~~_~~<br>~~7~~| |**Out 1:**Linear current<br>**Out 2:**non<br>004<br>013<br>014<br>005<br>E5_C-CX4A5M-000<br>E5_C-CX4D5M-000<br>E5_C-CC4A5M-000<br>E5_C-CC4D5M-000<br>E5_C-CX4A5M-014<br>E5_C-CX4D5M-014<br>E5_C-CX4A5M-005<br>E5_C-CX4D5M-005<br>E5_C-CX4A5M-004<br>E5_C-CX4D5M-004<br>E5_C-CX4A5M-013<br>E5_C-CX4D5M-013<br>~~es~~<br>———@~~”™“.~~-—22_!~~.:~~_-0W"w<br>_—~~_. ~~_—0~~n~~WYY"<br>~~a~~<br>~~———-~~|||| ||||004<br>E5_C-CC4A5M-004<br>E5_C-CC4D5M-004| |**Out 1:**Linear current<br>**Out 2:**Linear current|||005<br>E5_C-CC4A5M-005<br>E5_C-CC4D5M-005| ||||013<br>014<br>E5_C-CC4A5M-013<br>E5_C-CC4D5M-013<br>E5_C-CC4A5M-014<br>E5_C-CC4D5M-014<br>~~_~~<br>~~1~~| |**Out 1:**Linear<br>current<br>**Out 2:**Voltage<br>(pulse)<br>**Out 1:**Relay*<br>**Out 2:**Relay*<br>_ <br>~~_o—~~|<br>~~_o—~~|009<br>014<br>011<br>004<br>010<br>E5_C-PR4A5M-014<br>E5_C-PR4D5M-014<br>E5_C-PR4A5M-004<br>E5_C-PR4D5M-004<br>E5_C-CQ4A5M-011<br>E5_C-CQ4D5M-011<br>E5_C-PR4A5M-000<br>E5_C-PR4D5M-000<br>E5_C-CQ4A5M-009<br>E5_C-CQ4D5M-009<br>E5_C-CQ4A5M-000<br>E5_C-CQ4D5M-000<br>E5_C-CQ4A5M-010<br>E5_C-CQ4D5M-010<br> ~~=——~~<br>To :~~d]@__' ~~----_.+-.-.-~~-—~~=-=2“’"6+¢:W<br>——~~—-~~<br>~~_o—~~<br>~~a~~<br>~~H~~|| * Position proportional control model **007 009 010 011 013 014** Event Input 2, Event Input 2, Event Input 4 Event Input 6, Event Input 6, Event Input 4, Remote SP Communication Heater Burnout SSR Remote SP Heater Remote SP, Transfer Communication 3-phase heater defect detection Burnout SSR defect output Remote SP, Transfer alarm detection, Transfer output output 12 ## **E5DC model list (models 0 or 2 auxiliary outputs)** |**Output**|**Option No.* 1**|**Order code**<br>AC100-240V<br>**Order code**<br>AC/DC24V| |---|---|---| |||E5DC-RX2ASM-000<br>E5DC-RX2DSM-000| |**Out 1:**Relay|015<br>002|E5DC-RX0ASM-015*2<br>E5DC-RX0DSM-015*2<br>E5DC-RX2ASM-002<br>E5DC-RX2DSM-002| ||017|E5DC-RX2ASM-017<br>E5DC-RX2DSM-017| |*** 1Option No.:**<br>**002**<br>Communication,<br>Heater Burnout SSR<br>defect detection<br>**015**<br>Communication<br>**016**<br>Event Input 1<br>**017**<br>Event Input 1 ,<br>Heater Burnout SSR<br>defect detection<br>**Out 1:**Liner cuurent<br>002<br>015<br>017<br>015<br>015<br>016<br>E5DC-CX2ASM-015<br>E5DC-CX2DSM-015<br>E5DC-CX0ASM-015*2<br>E5DC-CX0DSM-015*2<br>E5DC-QX2ASM-017<br>E5DC-QX2DSM-017<br>E5DC-CX2ASM-016<br>E5DC-CX2DSM-016<br>E5DC-CX2ASM-000<br>E5DC-CX2DSM-000<br>E5DC-QX2ASM-002<br>E5DC-QX2DSM-002<br>E5DC-QX2ASM-000<br>E5DC-QX2DSM-000<br>E5DC-QX0ASM-015*2<br>E5DC-QX0DSM-015*2<br>**Out 1:**Voltage (pulse~~)mE SS~~<br>~~——=—|~~<br>|||| *** 2 Auxiliary outputs are not possible for these models.** **E5_C** General purpose temperature controllers ## **High performance & simplicity** The next generation E5_C temperature controller is setting a new global standard in terms of precision and user-friendly design. Best control performance, easy set-up and outstanding visibility of the white IP66 LCD display have been integrated into a space-saving housing with only 60 mm of depth. e Best contrast display using white LCD technology which is visible from a far distance and from any angle ## **Specifications** |||**E5CC**|**E5EC**|**E5AC**| |---|---|---|---|---| |**Power supply voltage**||A in model number: 100 to 240 VAC, 50/60 Hz<br>D in model number: 24 VAC, 50/60 Hz; 24 VDC||| |**Operating voltage range**||85% to 110% of rated supply voltage||| |**Power consumption**||6.5 VA max. at 100 to 240 VAC, and<br>4.1 VA max. at 24 VAC or<br>2.3 W max. at 24 VDC|8.3 VA max. at 100 to 240 VAC, and<br>5.5 VA max. at 24 VAC or<br>3.2 W max. at 24 VDC|9.0 VA max. at 100 to 240 VAC, and<br>5.6 VA max. at 24 VAC or<br>3.4 W max. at 24 VDC| |**Sensor input**||– Temperature input<br>Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II<br>Platinum resistance thermometer: Pt100 or JPt100<br>Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C<br>– Analog input<br>Current input (mA): 4 to 20 or 0 to 20<br>Voltage input (V): 1 to 5, 0 to 5, or 0 to 10||| |**Input impedance**||Current input: 150 Ω max., Voltage input: 1 Ω M min.<br>(Use a 1:1 connection when connecting the ES2-HB/THB.)||| |**Control method**||ON/OFF control or 2-PID control (with auto-tuning)||| |**Indication accuracy**||Thermocouple input: (±0.3% of PV<br>or ±1°C, whichever is greater) ±1<br>digit max.<br>Platinum resistance thermometer input:<br>(±0.2% of PV or ±0.8°C,<br>whichever is greater) ±1 digit max.<br>Analog input: ±0.2% FS ±1 digit max.<br>CT input: ±5% FS ±1 digit max.|Thermocouple input: (±0.3% of PV or ±1°C, whichever is greater) ±1<br>digit max.<br>Platinum resistance thermometer input: (±0.2% of PV or ±0.8°C,<br>whichever is greater) ±1 digit max.<br>Analog input: ±0.2% FS ±1 digit max.<br>CT input: ±5% FS ±1 digit max.<br>Potentiometer input: ±5% FS ±1 digit max.|| |**Auto-Tuning**||Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment||| |**Self-Tuning**||Yes||| |**Control outputs**|**Relay output**|SPST-NO, 250 VAC, 3 A (resistive load),<br>electrical life: 100,000 operations,<br>minimum applicable load: 5 V, 10 mA|SPST-NO, 250 VAC, 5 A (resistive load),<br>electrical life: 100,000 operations,<br>minimum applicable load: 5 V, 10 mA|| ||**Voltage output (for driving SSR)**|Output voltage: 12 VDC ±20% (PNP), max.<br>load current: 21 mA, with short-circuit pro-<br>tection circuit|Output voltage: 12 VDC ±20% (PNP), max.<br>load current: 40 mA, with short-circuit protection circuit<br>(The maximum load current is 21 mA for models with two control outputs.)|| ||**Linear current output**|4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000||| |**Auxiliary outputs**|**Number of outputs**|3|4|| ||**Output specifications**|SPST-NO relay outputs, 250 VAC,<br>Models with 3 outputs: 2 A (resistive load),<br>electrical life: 100,000 operations,<br>minimum applicable load: 5 V, 10 mA|SPST-NO relay outputs, 250 VAC,<br>Models with 4 outputs: 2 A (resistive load),<br>electrical life: 100,000 operations,<br>minimum applicable load: 5 V, 10 mA|| |**Event inputs**|**Number of inputs**|2 or 4 or 6 max (depends on the model)||| ||**External contact input specifications**|Contact input: ON: 1 k Ω max., OFF: 100 k Ω min.||| |||Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.||| |||Current flow: Approx. 7 mA per contact||| |**Setting method**||Digital setting using front panel keys or via Remote Software CX-Thermo V4.5||| |**Indication method**||11-segment digital display and individual indicators||| |**Multi SP**||Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.||| |**Other functions**||Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (including SSR<br>failure detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection func-<br>tions, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple programming, automatic<br>cooling coefficient adjustment||| |**Ambient operating temperature**||–10 to 55°C (with no condensation or icing)||| |**Ambient operating humidity**||25% to 85%||| |**Storage temperature**||–25 to 65°C (with no condensation or icing)||| |**Degree of protection**||Front panel: IP66, Rear case: IP20, Terminals: IP00||| |**Sampling period**||50 ms||| |**Size in mm (HxWxD)**||48x48x64|48x96x64|96×96×64| 12 13 **E5_C** General purpose temperature controllers ## **High performance & DIN-Track Mounting** The next generation E5_C temperature controller is setting a new global standard in terms of precision and user-friendly design. Best control performance, easy set-up and outstanding visibility of the white LCD display have been integrated into a space-saving housing with only 22.5mm wide. ## **Specifications** |||**E5DC**|| |---|---|---|---| |**Power supply voltage**||A in model number: 100 to 240 VAC,50/60 Hz|| |||D in model number: 24 VAC, 50/60 Hz; 24 VDC|D in model number: 24 VAC, 50/60 Hz; 24 VDC| |**Operating voltage range**||85% to 110% of rated supply voltage|| |**Power consumption**||4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC|| |**Sensor input**||– Temperature input|| |||Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II|| |||Platinum resistance thermometer: Pt100 or JPt100|| |||Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C|| |||– Analog input|| |||Current input (mA): 4 to 20 or 0 to 20|| |||Voltage input (V): 1 to 5, 0 to 5, or 0 to 10|| |**Input impedance**||Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB/THB.)|| |**Control method**||ON/OFF control or 2-PID control (with auto-tuning)|| |**Indication accuracy**||Thermocouple;*1 (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max.|| |**(ambient temperature of 23**°C**)**||Platinum resistance thermometer: (±0.2% of PV or ±0.8°C, whichever is greater) ±1 digit max.|| |||Analog input: ±0.2% FS ±1 digit max.|| |||CT input: ±5% FS ±1 digit max.|| |**Auto-Tuning**||Yes,40%/10% MV output limit selection, When using Heat /Cool : Automatic cool gain adjustment|| |**Self-Tuning**||Yes|| |**Control output**|**Relay output**|SPST-NO, 250 VAC, 3 A (resistive load), electrical life; 100,000 operations minimum.applicable load: 5 V, 10 mA|| ||**Voltage output (for driving SSR)**|Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit|Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit| ||**Linear current output**|4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000|| |**Auxiliary outputs**|**Number of outputs**|2 (depends on model)|| ||**Output specifications**|SPST-NO relay outputs: 250 VAC, 2 A (resistive load),|| |||Electrical life: 100,000 operations, Minimum applicable load:5 V, 10 mA|| |**Event inputs**|**Number of inputs**|1 (depends on model)|| ||**External contact input specifications**|Contact input ON: 1 kΩ max., OFF: 100 kΩ min.|| |||Non-contact input ON: Residual voltage 1.5 V max.; OFF: Leakage current 0.1 mA max.|| |||Current flow: approx. 7 mA per contact|| |**Setting method**||Digital setting using front panel keys|| |**Indication method**||11-segment digital displays and individual indicators|| |||Character height: PV 8.5 mm, SV: 8.0 mm|| |**Multi SP**||Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.*|Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.*| |**Other functions**||Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater|| |||burnout (HB) alam (including SSR failure (HB) alam), 40% AT, 100% AT, MV limiter, input digital filter, self|| |||tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change|| |||rate limit, simple calculations, temperature status display, simple programming, moving average of input|| |||value, and display brightness setting|| |**Ambient operating temperature**||–10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C (with no condensation or icing)|| |**Ambient operating humidity**||25% to 85%|| |**Storage temperature**||–25 to 65°C (with no condensation or icing)|| |**Degree of protection**||Main unit: IP20, Terminal unit: IP00|| |**Sampling Period**||50 ms|| |**Size in min (H×W×D)**||96x22.5x85|| * Only two set points are selectable for event inputs. 14 **E5_C** General purpose temperature controllers ## **USB communication cable E58-CIFQ2** **==> picture [441 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> E5CC E5EC E5AC E5DC<br>E58-CIFQ2<br>E58-CIFQ2-E ‒<br>E58-CIFQ2<br>7<br>st<br>E58-CIFQ2-E Exchange this head for E5EC/E5AC/E5DC<br>|<br>**----- End of picture text -----**<br> ## **E5CC/E5EC/E5AC optional tools** |**Option**|**Order code**| |---|---| |USB based configuration cable|E58-CIFQ2, E58-CIFQ2-E (for E5EC/E5AC/E5DC)| |PC based configuration and tuning software|EST2-2C-MV4| 1513 **==> picture [97 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> OMRON Corporation<br>**----- End of picture text -----**<br> **==> picture [136 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Industrial Automation Company<br>**----- End of picture text -----**<br> **==> picture [87 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Authorized Distributor:<br>**----- End of picture text -----**<br> Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. OMRON ELECTRONICS LLC Wegalaan 67-69-2132 JD Hoofddorp One Commerce Drive Schaumburg, The Netherlands IL 60173-5302 U.S.A. Tel: (31)2356-81 -300/Fax: (31)2356-81-388 Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRONNo. ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., Site ©In oeOMRON ems daeetion 2011-2013arseAllrantsRights RResenved L 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, specifications are subject to change without notice Alexandra Technopark, 200 Yin Cheng Zhong Road, . Singapore 119967 PuDong New Area, Shanghai, 200120, China Tel: (65) 6835-3011/Fax: (65) 6835-2711 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Cat. No. H176-E1-03 0613(1111) 0613(1111)
Updated at April 22, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →