E3X-HD0
Amplifier Unit, with Connector, Sensor Communications Unit
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 265.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
CSM_E3X-HD_DS_E_7_2 ## **Smart Fiber Amplifier Unit E3X-HD** ## **Easy and optimum settings for anyone Smart Fiber Amplifier Unit with Long-term Stable Detection** - Equipped with Smart Tuning, which automatically configures the settings to their optimum values with the press of a single button. - Highly usable design enables anyone to configure the settings easily. - Detects dirt, vibrations, and LED deterioration, and automatically compensates the incident level and the light intensity. - Unparalleled best-in-class power provides stable detections for low- - reflective workpieces and large workpieces (equipped with GIGA RAY II). **Refer to the** _**Fiber Sensors Technical Guide**_ **and** _**Safety Precautions**_ **on page 9.** ~~ao~~ For the most recent information on models that have been certified for safety standards, refer to your OMRON website. ## **Features** ## **Easy Greater operability and visibility** ~~a~~ **are realized by a universal design** **==> picture [507 x 467] intentionally omitted <==** **----- Start of picture text -----**<br> Greater operability and visibility Indications<br>are realized by a universal design Visibility is improved with digital displays and visible indicators.<br>New Concept: Visible Indicators<br>Operations L D DPC ST<br>Operation mode Flashing indicator Indicates that the<br>Symbolic buttons are easy to remember anywhere even for operators overseas. indicator to prevent enables preventive optimum settings<br>} 5 incorrect settings. maintenance. have been made.<br>L D DPC ST<br>OUT indicator OUT<br>TUNE UP DOWN MODE L/D Threshold (green) Incident level (red)<br>Compatibility for easy operation and incorrect operation prevention. Smart Tuning<br>Smart tuning for the optimum<br>settings with just one button.<br>Buttons are arranged<br>in a straight line. Smart Tuning<br>Pleasing operation even with gloves on. Automatically configure the settings to their<br>Hard to optimum values with the press of a single button.<br>operate.<br>With workpiece Without workpiece<br>Finger gets Settings are<br>c caught. “ a simultaneously<br>Conventional Models E3X-HD completed.<br>Sliding switches Pushbutton switches Incident level adjustment<br>(no sliding switches) Arc Design with workpiece<br>— A strong accent line gives a Ts " Press only twice. ea > Be Threshold setting<br>compact look to improve (Set to intermediate value<br>equipment design between the incident levelswith and without a workpiece. )<br>N—<br>Li Incident level adjustmentwithout workpiece<br>Stable<br>a<br>Long-term stable detection with no maintenance<br>| Smart Power Control APC Always ON Long-term stability<br>Maintenance-free operation by double compensation of light intensity (AUTO POWER CONTROL)<br>and incident level With APC<br>Automatically Without APC<br>Vibration LED — compensate light T e<br>Dirt Aged intensity Time<br>deterioration<br>Compensated =— OUT 5000L D DPC ST 9999 No Maintenance == OUT 5000L D DPC ST 9000Decreased DPC (DYNAMIC POWER CONTROL) incident level)Target value(displayed Incident level Compen-sated. Compen-sated. Compen-sated. no longer possible.compensation isFlashes when<br>Smart Power Automatically DPC<br>Control Setting value<br>compensate (threshold value)<br>+ incident level<br>Time<br>Light intensity compensation Incident level compensation<br>Light intensity<br>**----- End of picture text -----**<br> ## **Stable** a **1** omRON ~~a~~ **E3X-HD** ## **Ordering Information** ## **Fiber Amplifier Units** **Standard models (Dimensions** ➜ **page 12)** |**Appearance**|**Connecting method**|**Models**|**Models**| |---|---|---|---| |||**NPN output**|**PNP output**| ||Pre-wired (2 m)|**E3X-HD11 2M**|**E3X-HD41 2M**| ||Wire-saving Connector|**E3X-HD6**|**E3X-HD8**| ||M8 Connector|**E3X-HD14**|**E3X-HD44**| **==> picture [264 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Model for Sensor Communications Unit (Dimensions ➜ page 12)<br>**----- End of picture text -----**<br> ## **Accessories (sold separately)** ## **Wire-saving connectors (Required for models for Wire-saving Connectors.)** Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. * Protective stickers: provided. |**Type**<br>**Appearance**|**Cable length**<br>**Number of conductors**|**Cable length**<br>**Number of conductors**|**Cable length**<br>**Number of conductors**||**Models**||| |---|---|---|---|---|---|---|---| |Master<br>Connector|||3||**E3X-CN11**||| ||2 m||||||| |Slave<br>Connector|||1||**E3X-CN12**||| |**Sensor I/O Connectors (Required for models with M8 Connectors.)**|||||||| |Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.|||Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.||||| |**Size**<br>**Cable**|**Appearance**<br>**Cable type**<br>~~[|~~||||**Models**||| |M8<br>Standard<br>2 m<br>4-wire<br>5 m<br>2 m<br>5 m<br>Straight<br>L-shaped<br>~~oe~~<br>~~soe~~|||||**XS3F-M421-402-A**<br>**XS3F-M421-405-A**<br>**XS3F-M422-402-A**<br>**XS3F-M422-405-A**||| |**Mounting Bracket**|||**DIN Track**||||| |A Mounting Bracket is not provided with the Fiber Amplifier Unit and must be|A Mounting Bracket is not provided with the Fiber Amplifier Unit and must be||A Din Track is not provided with the Fiber Amplifier Unit and must be ordered||||| |ordered separately as required.|||separately as required.||||| |**Appearance**<br>**Model**|**Quantity**||**Appearance**||**Type**|**Models**|**Quantity**| ||||||Shallow type, total length: 1 m|**PFP-100N**|| |**E39-L143**|1||gZ||Shallow type, total length: 0.5 m|**PFP-50N**|1| ||||||Deep type, total length: 1 m|**PFP-100N2**|| **End Plate** Two End Plates are provided with the Sensor Communications Unit. End Plates are not provided with the Fiber Amplifier Unit and must be ordered separately as required. |**Appearance**|**Model**|**Quantity**| |---|---|---| ||**PFP-M**|1| **2** **E3X-HD** ## **Ratings and Specifications** |**Item**|**Item**|**Type**|**Standard**|**Standard**|**Standard**|**Model for Sensor Communications Unit *1**| |---|---|---|---|---|---|---| |||**NPN**<br>**output**|**E3X-HD11**|**E3X-HD6**|**E3X-HD14**|**E3X-HD0**| |||**PNP**<br>**output**|**E3X-HD41**|**E3X-HD8**|**E3X-HD44**|| |||**Connecting**<br>**method**|**Pre-wired**|**Wire-saving**<br>**Connector*2**|**M8 Connector**|**Connector for Sensor**<br>**Communications Unit**| |**Light source (wavelength)**|||Red, 4-element LED (625 nm)|||| |**Power supply voltage**|||12 to 24 VDC±10%, ripple (P-P) 10% max.|||Supplied from the connector through<br>the Sensor Communications Unit| |**Power**<br>**consump**<br>**tion**|**Normal mode**||720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)|||| ||**Eco ON**||530 mW max. (Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC)|||| ||**Eco LO**||640 mW max.(Current consumption: 26 mA max. at 24 VDC, 53 mA max.<br>at 12 VDC)|||−| |**Control output**|||Load power supply voltage: 26.4 VDC max., open-collector output<br>Load current: Groups of 1 to 3 Amplifier Units: 100mA max.,<br>Groups of 4 to 16 Amplifier Units: 20mA max.<br>Residual voltage:At load current of less than 10 mA: 1 V max.,<br>At load current of 10 to 100 mA: 2 V max.<br>OFF current: 0.1 mA max.|||−| |**Protection circuits**|||Power supply reverse polarity protection, output short-circuit<br>protection and output reverse polarity protection|||Power supply reverse polarity<br>protection and output short-circuit<br>protection| |**Response**<br>**time**|**Super-high-speed**<br>**mode (SHS)*3**||NPN outputs: Operate or reset: 50μs<br>PNP outputs: Operate or reset: 55μs|||−| ||<br>**High-speed mode (HS)**||Operate or reset: 250μs (default setting)|||| ||**Standard mode (Stnd)**||Operate or reset: 1 ms|||| ||**Giga-power mode (GIGA)**||Operate or reset: 16 ms|||| |**Maximum**|**connectable Units**||16 units|||with E3X-CRT: 16 units<br>with E3X-ECT: 30 units| |**Mutual interference prevention**|||Possible for up to 10 units (optical communications sync)*3|||| |**Auto power control (APC)**|||Always ON|||| |**Other functions**|||Power tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot),<br>zero reset, resetting settings, and Eco mode|||| |**Ambient illumination**<br>**(Receiver side)**|||Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.|||| |**Ambient temperature range**|||Operating:<br>Groups of 1 to 2 Amplifiers:−25 to 55°C,<br>Groups of 3 to 10 Amplifiers:−25 to 50°C,<br>Groups of 11 to 16 Amplifiers:−25 to 45°C<br>Storage:−30 to 70°C<br>(with no icing or condensation)|||Operating:<br>Groups of 1 to 2 Amplifiers: 0 to 55°C,<br>Groups of 3 to 10 Amplifiers: 0 to 50°C,<br>Groups of 11 to 16 Amplifiers: 0 to 45°C,<br>Groups of 17 to 30 Amplifiers: 0 to 40°C<br>Storage:−30 to 70°C<br>(with no icing or condensation)| |**Ambient humidity range**|||Operating and storage: 35% to 85% (with no condensation)|||| |**Insulation resistance**|||20 MΩmin. (at 500 VDC)|||| |**Dielectric strength**|||1,000 VAC at 50/60 Hz for 1 minute|||| |**Vibration resistance**<br>**(destruction)**|||10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X,<br>Y, and Z directions|||10 to 150 Hz with a 0.7-mm double<br>amplitude for 80 minutes each in X, Y,<br>and Z directions| |**Shock resistance (destruction)**|||500 m/s2for 3 times each in X, Y, and Z directions|||150 m/s2for 3 times each in X, Y, and<br>Z directions| |**Degree of protection**|||IEC 60529 IP50 (with Protective Cover attached)|||−| |**Weight (packed state/unit only)**|||Approx. 105 g/<br>Approx. 65 g|Approx. 60 g/<br>Approx. 20 g|Approx. 70 g/<br>Approx. 25 g|Approx. 65 g/Approx. 25 g| |**Materials**|**Case**||Polycarbonate (PC)|||Heat-resistant ABS (connector: PBT)| ||**Cover**||Polycarbonate (PC)|||| ||**Cable**||PVC|−||| |**Accessories**|||Instruction Manual|||| - *1. The E3X-ECT EtherCAT Sensor Communications Unit and the E3X-CRT CompoNet Sensor Communications Unit can be used. - *2. Use either the E3X-CN11 (master connector, 3 conductors) or the E3X-CN12 (slave connector, 1 conductor). *3. The communications function and mutual interference prevention function are disabled when the detection mode is set to Super-high-speed mode (SHS). When including E3X-DA-S with activated power tuning, mutual interference prevention is possible for up to 6 units. When including E3X-MDA with activated power tuning, mutual interference prevention is possible for up to 5 units. **3** **E3X-HD** ## **Sensing Distances** ## **Threaded Models** |**Sensing**<br>**method**|**Sensing direction**|**Size**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|Right-angle|M4|E32-T11N 2M|2,000|1,000|700|280| ||||E32-LT11N 2M|4,000*|3,500|2,300|920| ||Straight||E32-T11R 2M|2,000|1,000|700|280| ||||E32-LT11 2M|4,000*|4,000*|2,700|1,080| ||||E32-LT11R 2M|4,000*|3,500|2,300|920| |Reflective|Right-angle|M3|E32-C31N 2M|110|50|46|14| ||||E32-C21N 2M|290|130|90|39| |||M4|E32-D21N 2M|840|350|240|100| |||M6|E32-C11N 2M|780|350|320|100| ||||E32-LD11N 2M|840|350|240|100| ||Straight|M3|E32-D21R 2M|140|60|40|16| ||||E32-C31 2M|330|150|100|44| ||||E32-C31M 1M||||| |||M4|E32-D211R 2M|140|60|40|16| |||M6|E32-D11R 2M|840|350|240|100| ||||E32-CC200 2M|1,400|600|400|180| ||||E32-LD11 2M|860|360|250|110| ||||E32-LD11R 2M|840|350|240|100| * The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. ## **Cylindrical Models** |**Sensing**<br>**method**|**Size**|**Sensing direction**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|1 dia.|Top-view|E32-T223R 2M|450|250|150|60| ||1.5 dia.||E32-T22B 2M|680|400|220|90| ||3 dia.||E32-T12R 2M|2,000|1,000|700|280| |||Side-view|E32-T14LR 2M|750|450|260|100| |Reflective|1.5 dia.|Top-view|E32-D22B 2M|140|60|40|16| ||1.5 dia. +<br>0.5 dia.||E32-D43M 1M|28|12|8|4| ||3 dia.||E32-D22R 2M|140|60|40|16| ||||E32-D221B 2M|300|140|90|40| ||||E32-D32L 2M|700|300|200|90| ||3 dia. +<br>0.8 dia.||E32-D33 2M|70|30|20|8| ## **Flat Models** |**Sensing**<br>**method**|**Sensing direction**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---| ||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|Top-view|E32-T15XR 2M|2,000|1,000|700|280| ||Side-view|E32-T15YR 2M|750|450|260|100| ||Flat-view|E32-T15ZR 2M||||| |Reflective|Top-view|E32-D15XR 2M|840|350|240|100| ||Side-view|E32-D15YR 2M|200|100|52|24| ||Flat-view|E32-D15ZR 2M||||| ## **Sleeve Models** |**Sensing**<br>**method**|**Sensing direction**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---| ||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|Side-view|E32-T24R 2M|170|100|50|20| |||E32-T24E 2M|450|250|150|60| ||Top-view|E32-T33 1M|150|90|50|20| |||E32-T21-S1 2M|510|300|170|68| |||E32-TC200BR 2M|2,000|1,000|700|280| |Reflective|Side-view|E32-D24R 2M|70|30|20|8| |||E32-D24-S2 2M|120|53|45|14| ||Top-view|E32-D43M 1M|28|12|8|4| |||E32-D331 2M|14|6|4|2| |||E32-D33 2M|70|30|20|8| |||E32-D32-S1 0.5M|63|27|18|7| |||E32-D31-S1 0.5M||||| |||E32-DC200F4R 2M|140|60|40|16| |||E32-D22-S1 2M|250|110|72|30| |||E32-D21-S3 2M||||| |||E32-DC200BR 2M|840|350|240|100| |||E32-D25-S3 2M|250|110|72|30| **4** **E3X-HD** ## **Small-spot, Reflective Models** |**Type**|**Spot diameter**|**Center**<br>**distance**<br>**(mm)**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Variable spot|0.1 to 0.6 dia.|6 to 15|E32-C42 1M+E39-F3A|Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.|||| ||0.3 to 1.6 dia.|10 to 30|E32-C42 1M+E39-F17|Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm.|||| |Parallel light|4 dia.|0 to 20|E32-C31 2M+E39-F3C|Spot diameter of 4 mm max. at 0 to 20 mm.|||| ||||E32-C31N 2M+E39-F3C||||| |Integrated lens|0.1 dia.|5|E32-C42S 1M|Spot diameter of 0.1 mm at 5 mm.|||| ||6 dia.|50|E32-L15 2M|Spot diameter of 6 mm at 50 mm.|||| |Small-spot|0.1 dia.|7|E32-C41 1M+E39-F3A-5|Spot diameter of 0.1 mm at 7 mm.|||| ||0.5 dia.||E32-C31 2M+E39-F3A-5|Spot diameter of 0.5 mm at 7 mm.|||| ||||E32-C31N 2M+E39-F3A-5||||| ||0.2 dia.|17|E32-C41 1M+E39-F3B|Spot diameter of 0.2 mm at 17 mm.|||| ||0.5 dia.||E32-C31 2M+E39-F3B|Spot diameter of 0.5 mm at 17 mm.|||| ||||E32-C31N 2M+E39-F3B||||| ||3 dia.|50|E32-CC200 2M+E39-F18|Spot diameter of 3 mm at 50 mm.|||| ||||E32-C11N 2M+E39-F18||||| ## **High-power Beam Models** |**Type**|**Sensing direction**|**Aperture**<br>**angle**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam<br>models with<br>integrated lens|Right-angle|15°|E32-LT11N 2M|4,000*2|3,500|2,300|920| ||Top-view|10°|E32-T17L 10M|20,000*1|20,000*1|20,000*1|8,000| |||15°|E32-LT11 2M|4,000*2|4,000*2|2,700|1,080| ||||E32-LT11R 2M|4,000*2|3,500|2,300|920| ||Side-view|30°|E32-T14 2M|4,000*2|4,000*2|4,000*2|1,800| |Through-beam<br>models with<br>lenses|Right-angle|12°|E32-T11N 2M+E39-F1|4,000*2|4,000*2|4,000*2|2,000| |||6°|E32-T11N 2M+E39-F16|4,000*2|4,000*2|4,000*2|3,600| ||Top-view|12°|E32-T11R 2M+E39-F1|4,000*2|4,000*2|4,000*2|2,000| |||6°|E32-T11R 2M+E39-F16|4,000*2|4,000*2|4,000*2|3,600| ||Side-view|60°|E32-T11R 2M+E39-F2|1,450|800|500|200| ||Top-view|12°|E32-T11 2M+E39-F1|4,000*2|4,000*2|4,000*2|1,860| |||6°|E32-T11 2M+E39-F16|4,000*2|4,000*2|4,000*2|4,000*2| ||Side-view|60°|E32-T11 2M+E39-F2|2,300|1,320|860|320| ||Top-view|12°|E32-T51R 2M+E39-F1|4,000*2|4,000*2|3,900|1,500| |||6°|E32-T51R 2M+E39-F16|4,000*2|4,000*2|4,000*2|4,000*2| ||Side-view|60°|E32-T51R 2M+E39-F2|1,400|720|500|200| ||Top-view|12°|E32-T81R-S 2M+E39-F1|4,000*2|4,000*2|2,700|1,000| |||6°|E32-T81R-S 2M+E39-F16|4,000*2|4,000*2|4,000*2|1,800| ||Side-view|60°|E32-T81R-S 2M+E39-F2|1,000|550|360|140| ||Top-view|12°|E32-T61-S 2M+E39-F1|4,000*2|4,000*2|4,000*2|1,800| |||6°|E32-T61-S 2M+E39-F16|4,000*2|4,000*2|4,000*2|3,100| ||Side-view|60°|E32-T61-S 2M+E39-F2|1,680|900|600|240| ||Top-view|12°|E32-T51 2M+E39-F1-33|4,000*2|4,000*2|2,300|1,400| |||6°|E32-T51 2M+E39-F16|4,000*2|4,000*2|4,000*2|4,000*2| |Reflective<br>models with<br>integrated lens|Top-view|4°|E32-D16 2M|40 to 2,800|40 to 1,400|40 to 900|40 to 480| *1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. - *2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. ## **Narrow View Models** |**Sensing**<br>**method**|**Sensing direction**|**Aperture angle**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|Side-view|1.5°|E32-A03 2M|3,220|1,780|1,200|500| ||||E32-A03-1 2M||||| |||3.4°|E32-A04 2M|1,280|680|450|200| |||4°|E32-T24SR 2M|4,000*|2,200|1,460|580| ||||E32-T24S 2M|4,000*|2,600|1,740|700| ||||E32-T22S 2M|4,000*|3,800|2,500|1,000| * The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. **5** **E3X-HD** ## **Models for Detection without Background Interference** |**Sensing method**|**Sensing direction**|**Model**|**Sensing distance (mm)**|**Sensing distance (mm)**|**Sensing distance (mm)**|**Sensing distance (mm)**| |---|---|---|---|---|---|---| ||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Limited-reflective|Flat-view|E32-L16-N 2M|0 to 15|||0 to 12| |||E32-L24S 2M|0 to 4|||| ||Side-view|E32-L25L 2M|5.4 to 9 (center 7.2)|||| ## **Transparent Object Detection (Retro-reflective Models)** |**Sensing method**|**Feature**|**Size**|**Model**|**Sensing distance (mm)**|**Sensing distance (mm)**|**Sensing distance (mm)**|**Sensing distance (mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Retro-reflective|Film detection|M3|E32-C31 2M<br>+E39-F3R<br>+E39-RP37|250||200|---| ||Square|---|E32-R16 5M|150 to 1,500|||| ||Threaded|M6|E32-R21 2M|10 to 250|||| ||Hex-shaped||E32-LR11NP 2M<br>+E39-RP1|1,350|1,200|1,000|550| ## **Transparent Object Detection (Limited-reflective Models)** |**Sensing method**|**Feature**|**Sensing direction**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Limited-reflective|Small size|Flat-view|E32-L24S 2M|0 to 4|||| ||Standard||E32-L16-N 2M|0 to 15|||0 to 12| ||Glass substrate<br>alignment, 70°C||E32-A08 2M|10 to 20|||---| ||Standard/long-distance||E32-A12 2M|12 to 30|||---| ||Side-view form|Side-view|E32-L25L 2M|5.4 to 9 (center 7.2)|||| ||Glass substrate<br>mapping, 70°C|Top-view|E32-A09 2M|15 to 38|||---| ## **Chemical-resistant, Oil-resistant Models** |**Sensing**<br>**method**|**Type**|**Sensing direction**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-<br>beam|Oil-resistant|Right-angle|E32-T11NF 2M|4,000*1|4,000*1|4,000*1|2,200| ||Chemical/oil-resistant|Top-view|E32-T12F 2M|4,000*1|4,000*1|4,000*1|1,600| ||||E32-T11F 2M|4,000*1|4,000*1|2,600|1,000| |||Side-view|E32-T14F 2M|1,400|800|500|200| ||Chemical/oil-resistant at<br>150°C|Top-view|E32-T51F 2M|4,000*1|2,800|1,800|700| |Reflective|Semiconductors: Cleaning,<br>developing, and etching;<br>60°C|Top-view|E32-L11FP 5M|8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),<br>19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)|||| ||Semiconductors: Resist<br>stripping; 85°C||E32-L11FS 5M|8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),<br>32 to 44 mm from center of mountinghole A(Recommended sensingdistance: 35 mm)|||| ||Chemical/oil-resistant||E32-D12F 2M|--- *2|190|130|60| ||Chemical-resistant cable||E32-D11U 2M|840|350|240|100| *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. - *2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin. ## **Bending-resistant Models** |**Sensing method**|**Size**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---| ||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|1.5 dia.|E32-T22B 2M|680|400|220|90| ||M3|E32-T21 2M||||| ||M4|E32-T11 2M|2,500|1,350|900|360| ||Square|E32-T25XB 2M|500|300|170|70| |Reflective|1.5 dia.|E32-D22B 2M|140|60|40|16| ||M3|E32-D21 2M||||| ||3 dia.|E32-D221B 2M|300|140|90|40| ||M4|E32-D21B 2M||||| ||M6|E32-D11 2M|840|350|240|100| ||Square|E32-D25XB 2M|240|100|60|30| **6** **E3X-HD** ## **Heat-resistant Models** |**Sensing method**|**Size**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---| ||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|100°C|E32-T51R 2M|1,600|800|560|225| ||150°C|E32-T51 2M|2,800|1,500|1,000|400| ||200°C|E32-T81R-S 2M|1,000|550|360|140| ||350°C|E32-T61-S 2M|1,680|900|600|240| |Reflective|100°C|E32-D51R 2M|670|280|190|80| ||150°C|E32-D51 2M|1,120|450|320|144| ||200°C|E32-D81R-S 2M|420|180|120|54| ||300°C|E32-A08H2 2M|10 to 20|||---| |||E32-A09H2 2M|20 to 30(center 25)|||---| ||350°C|E32-D611-S 2M|420|180|120|54| |||E32-D61-S 2M||||| ||400°C|E32-D73-S 2M|280|120|80|36| ## **Area Detection Models** |**Sensing method**|**Type**|**Sensing width**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|Area|11 mm|E32-T16PR 2M|3,100|1,700|1,120|440| ||||E32-T16JR 2M|2,750|1,500|960|380| |||30 mm|E32-T16WR 2M|4,000*|2,600|1,700|680| |Reflective|Array|11 mm|E32-D36P1 2M|700|300|200|90| - The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. ## **Liquid-level Detection Models** |**Sensing method**|**Tube diameter**|**Feature**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Tube-mounting|3.2, 6.4,<br>or 9.5 dia.|Stable residual<br>quantitydetection|E32-A01 5M|Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm,<br>Recommended wall thickness: 1 mm|||| ||8 to 10 dia.|Mounting at<br>multiple levels|E32-L25T 2M|Applicable tube: Transparent tube with a diameter of 8 to 10 mm,<br>Recommended wall thickness: 1 mm|||| ||No restrictions|Large tubes|E32-D36T 5M|Applicable tube: Transparent tube(no restrictions on diameter)|||| |Liquid contact (heat-resistant<br>up to 200°C)|---|---|E32-D82F1 4M|Liquid-contact type|||| ## **Vacuum-resistant Models** |**Sensing method**|**Heat-resistant temperature**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---| ||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Through-beam|120°C|E32-T51V 1M|720|400|260|100| |||E32-T51V 1M+E39-F1V|2,000*|2,000*|1,360|520| ||200°C|E32-T84SV 1M|1,760|950|640|260| * The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm. ## **Models for FPD, Semiconductors, and Solar Cells** |**Sensing method**|**Application**|**Operating**<br>**temperature**|**Model**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**|**Sensing distance(mm)**| |---|---|---|---|---|---|---|---| |||||**Giga mode**|**Standard mode**|**High-speed**<br>**mode**|**Super-high-**<br>**speed mode**| |Limited-reflective|Glass presence detection|70°C|E32-L16-N 2M|0 to 15|||0 to 12| ||Glass substrate alignment||E32-A08 2M|10 to 20|||---| |||300°C|E32-A08H2 3M||||| |||70°C|E32-A12 2M|12 to 30|||---| ||Glass substrate mapping||E32-A09 2M|15 to 38|||---| |||300°C|E32-A09H2 2M|20 to 30 (center 25)|||---| ||Wet processes: Cleaning, Resist<br>developingand etching|60°C|E32-L11FP 5M|8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),<br>19 to 31 mm from center of mountinghole A(Recommended sensingdistance: 22 mm)|||| ||Wet process:<br>Resist stripping|85°C|E32-L11FS 5M|8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm),<br>32 to 44 mm from center of mountinghole A(Recommended sensingdistance: 35 mm)|||| |Through-beam|Wafer mapping|70°C|E32-A03 2M|3,220|1,780|1,200|500| ||||E32-A03-1 2M||||| ||||E32-A04 2M|1,280|680|450|200| ||||E32-T24SR 2M|4,000*|2,200|1,460|580| ||||E32-T24S 2M|4,000*|2,600|1,740|700| - The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. **7** **E3X-HD** **I/O Circuit Diagrams** ## **NPN Output** **==> picture [533 x 473] intentionally omitted <==** **----- Start of picture text -----**<br> Models Operation mode Timing chart indicatorsL/D Output circuit<br>Incident light<br>OUT indicatorNo incident lightLit Display OUT indicator (orange) Brown<br>Light-ON (orange)Output Not litON Es L lit. 'f=] @ O 1 Black Load<br>transistor OFF 4<br>Load Set Photoelectric Control output 12 to<br>E3X-HD11 (e.g., relay) Reset (Between blue andblack leads) pax)pad Sensor maincircuit 24 VDC<br>E3X-HD6<br>E3X-HD14 Incident light ,<br>OUT indicatorNo incident lightLit a 3 Blue<br>(orange) Not lit<br>Dark-ON Outputtransistor OFFON a D lit. • M8 Connector Pin Arrangement 2 4<br>Load Set oO 1 O 3<br>(e.g., relay) Reset (Between blue and Note: Pin 2 is not used.<br>black leads)<br>PNP Output<br>Models Operation mode Timing chart indicatorsL/D Output circuit<br>Incident light<br>OUT indicatorNo incident lightLit s Display OUT indicator (orange) A Brown<br>(orange) Not lit =l 1<br>E3X-HD41E3X-HD8 Light-ON OutputtransistorLoad(e.g., relay) ResetOFFSetON = (Between blue andblack leads) - L lit. Pfc PhotoelectricSensor maincircuit 4 Black Control outputLoad 12 to 24 VDC<br>E3X-HD44 Incident light Blue<br>No incident light a O 3<br>OUT indicator Lit<br>(orange) Not lit<br>Dark-ON Outputtransistor OFFON D lit. • M8 Connector Pin Arrangement 2 4<br>Load Set 1 3<br>(e.g., relay) Reset = Note: Pin 2 is not used. OO<br>(Between blue and<br>black leads)<br>ON delay OFF delay One-shot Plug (Sensor I/O Connector)<br>| Terminal number<br>Incident light Incident light Incident light Wire color<br>No incident lightON T No incident lightON T No incident lightON T 3 4 2 1 123 BrownWhiteBlue<br>Light-ON Light-ON Light-ON 4 Black<br>OFF OFF OFF<br>T T T<br>ON ON ON<br>Dark-ON Dark-ON Dark-ON XS3F-M421-402-A XS3F-M422-402-A<br>OFF OFF OFF XS3F-M421-405-A XS3F-M422-405-A<br>Note: Timing Charts for Timer Settings (T: Set Time) Wire color Connection pin Application<br>Brown 1 Power supply (+V)<br>White 2 ---<br>Blue 3 Power supply (0 V)<br>Black 4 Output<br>**----- End of picture text -----**<br> ## **PNP Output** **Note:** Timing Charts for Timer Settings (T: Set Time) **Note:** Pin 2 is not used. ## **Nomenclature** **==> picture [352 x 169] intentionally omitted <==** **----- Start of picture text -----**<br> [L/D Indicator] [DPC Indicator] [ L/D Button] A<br>Indicates the setting status: Turns ON when Dynamic Power Control is effective. Use to switch between<br>Light-ON (L) or Dark-ON (D).<br>Light-ON (L) and Dark-ON (D).<br>[OUT Indicator] [ST Indicator]<br>Turns ON when Turns ON when Smart Tuning<br>the output is ON. is in progress.<br>on! Aitenne =—_ =<br> vFF pee<br>2 @rune ii lend uP | DOWN ian<br>Threshold Level Incident Level [ MODE Button] O<br>Green digital display Red digital display Use to switch between Detection<br>Mode and Setting Mode.<br>[ TUNE Button] e [+−UP/DOWN Button]<br>Automatically sets the emitter Used to fine-tune the threshold<br>power and set values. or change set values.<br>**----- End of picture text -----**<br> **8** **E3X-HD** ## **Safety Precautions** **Refer to the** _**Fiber Sensors Technical Guide**_ **for precautions that apply to all Fiber Sensors.** ## **Warning** **This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes.** **Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire.** **Never use the product with AC power supply. Otherwise, explosion may result.** ## **Precautions for Safe Use** The following precautions must be observed to ensure safe operation of the product. Doing so may cause damage or fire. **1.** Do not install the product in the following locations. - Locations subject to direct sunlight - Locations subject to condensation due to high humidity - Locations subject to corrosive gas - Locations subject to vibration or mechanical shocks exceeding the rated values - Locations subject to exposure to water, oil, chemicals - Locations subject to stream - Locations subjected to strong magnetic field or electric field **2.** Do not use the product in environments subject to flammable or explosive gases. **3.** To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. **4.** High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage. **5.** Do not apply load exceeding the ratings. Otherwise, damage or fire may result. **6.** Do not short the load. Otherwise, damage or fire may result. **7.** Connect the load correctly. **8.** Do not miswire such as the polarity of the power supply. **9.** Do not use the product if the case is damaged. **10.** Burn injury may occur. The product surface temperature rises depending on application conditions, such as the ambient temperature and the power supply voltage. Attention must be paid during operation or cleaning. **11.** When setting the Sensor, be sure to check safety, such as by stopping the equipment. **12.** Be sure to turn off the power supply before connecting or disconnecting wires. **13.** Do not attempt to disassemble, repair, or modify the product Unit in any way. ## **Precautions for Correct Use** - Be sure to mount the unit to the DIN track until it clicks. - Use an extension cable with a minimum thickness of 0.3 mm[2] and less than 100 m long. - Do not subject the cable to more than the following forces. ⋅ - Pull: 40 N; torque: 0.1 N m; pressure: 20 N; bending: 29.4 N - The Sensor is ready to operate 200 ms after the power supply is turned ON. - When using Amplifier Units with Wire-saving Connectors, attach the protective stickers (provided with E3X-CN-series Connectors) on the unused power pins to prevent electrical shock and short circuiting. When using Amplifier Units with Connectors for Communications Units, attach the protective caps (provided with E3X-CRT/ECT Sensor Communications Unit). **==> picture [211 x 82] intentionally omitted <==** **----- Start of picture text -----**<br> Amplifier Unit with Amplifier Unit with Connector<br>Wire-saving Connector for Communications Unit<br>Protective Sticker<br>Power Supply Protective Cap<br>Connecting Terminal<br>**----- End of picture text -----**<br> - Output pulses may occur when the power supply is turned OFF. Turn OFF the power supply to the load or load line first. - Excessive incident light cannot be sufficiently handled by the mutual interference prevention function and may cause malfunction. To prevent this, set a higher threshold level. - Make sure that the power supply is turned OFF before connecting, separating, or adding Amplifier Units. - Do not pull on or apply excessive pressure or force to the Fiber Unit when it is attached to the Amplifier Unit. - The E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S Mobile Consoles cannot be used. - Mutual interference prevention on the E3X-HD Series does not function among the E3NX-FA, E3X-DA-N, E3X-SD, or E3X-NA Fiber Amplifier Units. - Mutual interference prevention on the E3X-HD Series does function among the E3X-DA-S and E3X-MDA Fiber Amplifier Units. - The E3X-CRT and E3X-ECT Sensor Communications Unit can be used with the E3X-HD0, but the E3X-DRT21-S and E3NW-ECT Sensor Communications Units cannot be used. - Always keep the protective cover in place when using the Amplifier Unit. - Do not use thinner, benzine, acetone, and kerosene for cleaning. **For technical information and product FAQs, refer to the** _**Technical Guide**_ **on your OMRON website.** **14.** When disposing of the product, treat it as industrial waste. **15.** Do not use the Sensor in water, rainfall, or outdoors. **9** **E3X-HD** ## **Mounting the Fiber Amplifier Units** ## � **Mounting on DIN Track** 1. Let the hook on the Amplifier Unit’s Fiber Unit connection side catch the track and push the unit until it clicks. **==> picture [215 x 24] intentionally omitted <==** **----- Start of picture text -----**<br> Fiber Unit Connection Side Hook<br>� Removing from DIN Track<br>1. Push the unit in the direction 1. 2 1<br>**----- End of picture text -----**<br> 2. Lift it up in the direction 2. **Note:** Refer to _I/O Circuit Diagrams_ or check the side of the unit for wire color and role indications. ## � **Mounting Amplifier Units in Group (Connector Type Models)** 1. Mount the Fiber Amplifier units one at a time onto the DIN track and DIN Track push them until they click. 2 2. Slide the Fiber Amplifier units in the direction 2. 3. Use End Plates (PFP-M: separately sold) at the both ends of the grouped Fiber Amplifier units to prevent them from separating due to vibration or other cause. 4. Tighten the screw on the End Plates using a driver. 3 4 Tighten the screw while pressing the End Plate. - Under environments such as vibration, use an end plates even with a single Fiber Amplifier Unit. - The maximum numbers of connectable Amplifier Units are given in the following table. |||**Maximum**<br>**number of**<br>**interconnected**<br>|**Maximum**<br>**number of**<br>**mutual**<br>**interference**| |---|---|---|---| |**E3X-HD series standard models**<br>**(E3X-HD11/HD41/HD6/HD8)**<br>**With E3X-ECT**||16<br>30|**prevention**<br>10<br>10| |**E3X-HD0**|<br>**With E3X-CRT**|16|10| - The mutual interference prevention function cannot be used if the detection mode is set to super-high-speed mode (SHS). - If Units are to be connected, the allowable ambient temperature will change with the number of Units that are connected. Check the Ratings and Specifications. ## **Mounting Fiber Units** ## � **Use Fiber Cutter** Cut a thin fiber as follows. For standard fibers, insert to the desired cutting position and cut. **==> picture [243 x 268] intentionally omitted <==** **----- Start of picture text -----**<br> The fiber is Thin Fiber Attachment<br>shipped loosely (E39-F9)<br>1. tightened as<br>shown in the<br>figure at the right. Loosely tighten.<br>Adjust the fiber<br>to the desired<br>2.<br>length and fully<br>tighten.<br>Fiber Cutter<br>Insert the Fiber E39-F4<br>3. Unit into E39-F4<br>and cut it. Thin-diameter<br>Fiber Unit Hole × 2<br>Standard Fiber<br>Unit Hole<br>(dia. 2.2 mm) × 3<br>About 0.5 mm<br>Finished state.<br>4. (Correctly cut Insertion direction<br>end) Note: The insertion direction into the Fiber<br> Amplifier Unit is shown in the above figure.<br>**----- End of picture text -----**<br> ## � **Mount Fiber Unit** 1. Open the protective cover. 2. Raise the lock lever. Lock Lever Lock 3. Insert the Fiber Unit in the fiber Release 4 Protective unit hole to the bottom. 2 1 Cover 4. Return the lock lever to the original position and fix the 3 Fiber Unit. Fiber Unit • When mounting a coaxial reflective Fiber Unit, insert the single-core Fiber Unit to the upper hole (Emitter side) and the multi-core Fiber Unit to the lower hole (Receiver side). The cables for the Single-core Fiber Single Core Units (Emitters) have identification Multi Core marks. Refer to the dimensions diagrams for details. - When removing the Fiber Unit, follow the above steps in reverse order. To maintain the characteristics of the Fiber Unit, make sure the lock is released before removing the Fiber Unit. - Always turn OFF the power before connecting or disconnecting Units. **10** **E3X-HD** **(Unit: mm)** **Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.** ## **Dimensions** ## **Fiber Amplifier Units** ## **Pre-wired Amplifier Units E3X-HD11 E3X-HD41** **==> picture [481 x 239] intentionally omitted <==** **----- Start of picture text -----**<br> DPC indicator<br>L/D indicator ST indicator<br>21.7 27.1<br>Vinyl-insulated round cable, 4 dia., 3 conductors<br>OUT indicator Incident level (conductor cross-section: 0.2 mm [2] , insulation diameter: 1.1 mm),<br>Threshold level red digital display standard cable length: 2 m<br>green digital display Minimum bending radius: 12 mm<br>Vd 10 aE = gee6 0908} —<br>DIN track mounting With Mounting Braket Attached<br>5.1 146.9<br>170° (max. value with cover open) Note: When using E39-L143 Mounting<br>104.8 Brackets, there will be small gaps<br>(max. value 5.1 between the Amplifier Units if they<br>with cover are mounted side by side.<br>open)<br>Ad Two, —<— ct | |<br>2.4-dia. 49.2<br>4.5 b:all holes 33.5 3.4 (16.5) ( —=™ io 33.5 3.4 (16.5) | rea——<br>5.65 ' ES) Tp 20.5 (37.9) (20.3) Optical communications12.7 Two, 3.2-dia.holes ee a 20.5 (9.4) SE 16 4.3 ae Opticalcommunications12.7<br>= 71.8 2a 71.8<br>PFP-@N DIN Track E39-L143 Mounting Bracket<br>(sold separately) Mouting Holes (sold separately, SUS304)<br>Fiber Attachment (E39-F9) attached Two-M3<br>3.4 4.4<br>10.3<br>ft 16 —obeSeES-<br>29.9 16<br>**----- End of picture text -----**<br> ## **Amplifier Units with Wire-saving Connectors E3X-HD6 E3X-HD8** **==> picture [467 x 292] intentionally omitted <==** **----- Start of picture text -----**<br> DPC indicator<br>L/D indicator ST indicator<br>iw 21.7 27.1<br>-<br>CL - sessseeee|—— Hr -<br>OUT indicator Incident level<br>Threshold level red digital display<br>green digital display<br>10<br>DIN track mounting With Mounting Braket Attached<br>5.1 146.9<br>170° (max. value with cover open) Note: When using E39-L143 Mounting<br> Brackets, there will be small gaps<br> between the Amplifier Units if they<br>104.8 5.1 are mounted side by side.<br>(max. value<br>with cover<br>open) 4.5 5 Two,2.4-dia. holes 33.5 3.4 (16.5) \ 7 La, A * 49.2 33.5 3.4 (16.5) (| 7 =a A *<br>(13) (13)<br>Optical<br>5.65 (=) ng 20.5 ee 4 Two, 3.2-dia. eS e e 4.3 ee communications<br>(37.9) (20.3) holes 20.5 (9.4) 16<br>71.8 PFP-@N DIN Track 71.8 E39-L143 Mounting Bracket<br>(sold separately) (sold separately, SUS304)<br>Fiber Attachment (E39-F9) attached<br>Mouting Holes 3.4 4.4<br>Two-M3<br>10.3<br>29.9 16<br>16<br>* The cable diameters are as follows:<br>E3X-CN11 (3 conductors) 4.0 dia.<br>E3X-CN12 (1 conductor) 2.6 dia.<br>**----- End of picture text -----**<br> **11** **E3X-HD** ## **Amplifier Units with M8 Connectors E3X-HD14 E3X-HD44** **==> picture [466 x 293] intentionally omitted <==** **----- Start of picture text -----**<br> DPC indicator<br>L/D indicator ST indicator<br>21.7 27.1<br>— — [sexes egee|— — I -<br>OUT indicator Incident level<br>Threshold level red digital display<br>green digital display<br>10<br>DIN track mounting With Mounting Braket Attached<br>5.1 146.9<br>170° (max. value with cover open) Note: Brackets, there will be small gaps When using E39-L143 Mounting<br> between the Amplifier Units if they<br>104.8 5.1 are mounted side by side.<br>(max. value<br>with cover<br>open)<br>4.5 i Two,2.4-dia.holes 33.5 3.4 (16.5) (ACRE A * 49.2 33.5 3.4 (16.5) (EE A *<br>Lad —b (I fri en 12.7 ree GG : 12.7<br>5.65 EES a 20.5 e (37.9) aee (20.3) 11.2 IN M8 connector Two, 3.2-dia.holes aiW 20.5 (9.4) 16 4.3 Opticalcommunications<br>71.8 71.8<br>PFP-@N DIN Track E39-L143 Mounting Bracket<br>(sold separately) (sold separately, SUS304)<br>Fiber Attachment (E39-F9) attached<br>Mouting Holes 4.4 3.4<br>Two-M3<br>10.3<br>29.9 16<br>16<br>* The cable diameters are as follows:<br>E3X-CN11 (3 conductors) 4.0 dia.<br>E3X-CN12 (1 conductor) 2.6 dia.<br>**----- End of picture text -----**<br> ## **Amplifier Unit with Connector for Sensor Communications Unit E3X-HD0** **==> picture [261 x 254] intentionally omitted <==** **----- Start of picture text -----**<br> DPC indicator<br>L/D indicator ST indicator<br>_— 21.7 aaa 27.1 =<br>esses— FE<br>OUT indicator Incident level<br>Threshold level red digital display<br>green digital display<br>13.8<br>11.5<br>10 DIN track mounting<br>| I<br>100° (max. value with cover open)<br>103.5<br>104.8<br>(max. value 5.1 71.8<br>with cover<br>open) [ \ _ f ) Two,2.4-dia. iy<br>4.5 holes<br>33.5 (16.5)<br>3.4 9.9<br>5.65<br>20.5<br>3.4<br>(37.9) (39.3)<br>4 90.8 \<br>Optical communications<br>PFP-@N DIN Track (sold separately)<br>Fiber Attachment (E39-F9) attached<br>**----- End of picture text -----**<br> **Refer to** _**E32 Series**_ **for details on Fiber Units.** ~~CT~~ **12** ## Terms and Conditions Agreement ## Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. ## Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. ## Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. ## Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ## Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. ## Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. ## Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. ## Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. **In the interest of product improvement, specifications are subject to change without notice.** ## **OMRON Corporation** ## **Industrial Automation Company** 2016.6 **http://www.ia.omron.com/** (c)Copyright OMRON Corporation 2016 All Right Reserved.
Updated at June 9, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →