Image not available
Illustrative purposes only
E2FX10E1
INDUCTIVE PROXIMITY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: OMRON / PARTNER STOCK
- Product type: Inductive Proximity Sensors
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 382.43 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Resin-case Proximity Sensor E2F** CSM_E2F_DS_E_6_2 ## **Proximity Sensor with Resin Case with Superb Water Resistance** - IP68 protection. - Mutual interference prevention with models with different frequencies is also available. Be sure to read _Safety Precautions_ on page 5. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. ## **Ordering Information** **Sensors [Refer to** _**Dimensions**_ **on page** _**6**_ **.]** |**Model**|**Model**|**Sensing distance**<br>~~==~~|**Sensing distance**<br>~~==~~|**Sensing distance**<br>~~==~~|**Sensing distance**<br>~~==~~|**Output configuration**<br>~~==~~<br>~~ee~~|**Model**<br>~~==~~|**Model**<br>~~==~~| |---|---|---|---|---|---|---|---|---| ||||||||**Operation mode**<br>~~==~~|| ||||||||**NO**<br>~~==~~<br>~~ee~~|**NC**| |Shielded<br>~~Fo~~|M8|1.5 mm|1.5 mm|||DC 3-wire, NPN<br>~~ee~~<br>~~es~~|**E2F-X1R5E1 2M**<br>~~ee~~<br>~~ee~~|**E2F-X1R5E2 2M**| |||||||DC 3-wire, PNP<br>~~ee~~<br>~~es~~<br>~~es~~|**E2F-X1R5F1 2M**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**E2F-X1R5F2 2M**| |||||||AC 2-wire<br>~~es~~<br>~~es~~<br>~~es~~|**E2F-X1R5Y1 2M**<br>~~ee~~<br>~~ee~~<br>~~ee~~|**E2F-X1R5Y2 2M**| ||M12|2 mm|2 mm|||DC 3-wire, NPN<br>~~es~~<br>~~es~~<br>~~es~~|**E2F-X2E1 2M***<br>~~ee~~<br>~~ee~~<br>~~ee~~|**E2F-X2E2 2M***| |||||||DC 3-wire, PNP<br>~~es~~<br>~~es~~|**E2F-X2F1 2M**<br>~~ee~~<br>~~ee~~|**E2F-X2F2 2M**| |||||||AC 2-wire<br>~~es~~<br>~~**e**s~~<br>~~s~~|**E2F-X2Y1 2M***<br>~~ee~~<br>~~s~~<br>~~ee~~|**E2F-X2Y2 2M***| ||M18|5 mm|5 mm|||DC 3-wire, NPN<br>~~**e**s~~<br>~~s~~<br>~~es~~|**E2F-X5E1 2M***<br>~~s~~<br>~~ee~~<br>~~ee~~|**E2F-X5E2 2M***| |||||||DC 3-wire, PNP<br>~~**e**s~~<br>~~s~~<br>~~es~~|**E2F-X5F1 2M***<br>~~s~~<br>~~ee~~<br>~~ee~~|**E2F-X5F2 2M**| |||||||AC 2-wire<br>~~es~~<br>~~es~~<br>~~ee~~|**E2F-X5Y1 2M***<br>~~ee~~<br>~~es~~<br>~~ee~~|**E2F-X5Y2 2M***| ||M30||10 mm|||DC 3-wire, NPN<br>~~es~~<br>~~ee~~<br>~~ee~~|**E2F-X10E1 2M***<br>~~es~~<br>~~ee~~<br>~~ee~~|**E2F-X10E2 2M***| |||||||DC 3-wire, PNP<br>~~ee ~~<br>~~ee~~|**E2F-X10F1 2M**<br> ~~ee~~<br>~~ee~~|**E2F-X10F2 2M**| |||||||||| |||||||AC 2-wire<br>~~ee~~<br>~~ee~~|**E2F-X10Y1 2M***<br>~~ee~~<br>~~ee~~|**E2F-X10Y2 2M***| * Models with different frequencies are also available. The model numbers are E2F-X @@@ 5 (e.g., E2F-X5E15). ## **Accessories (Order Separately)** **Protective Covers** Refer to _Y92_ @ for details. **1** omron ~~a~~ **E2F** ## **Ratings and Specifications** |**Model**|**Model**|**E2F-X1R5E**@<br>**E2F-X1R5F**@<br>**E2F-X1R5Y**@|**E2F-X2E**@<br>**E2F-X2F**@<br>**E2F-X2Y**@|**E2F-X5E**@<br>**E2F-X5F**@<br>**E2F-X5Y**@|**E2F-X10E**@<br>**E2F-X10F**@<br>**E2F-X10Y**@| |---|---|---|---|---|---| |**Item**|||||| |**Sensing distance**||1.5 mm±10%|2 mm±10%|5 mm±10%|10 mm±10%| |**Set distance**||0 to 1.2 mm|0 to 1.6 mm|0 to 4 mm|0 to 8 mm| |**Differential travel**||10% max. of sensing distance|||| |**Detectable object**||Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to_Engineering Data_on page 3.)|||| |**Standard sensing**<br>**object**||Iron, 8×8×1 mm|Iron, 12×12×1 mm|Iron, 18×18×1 mm|Iron, 30×30×1 mm| |**Response frequency**<br>***1**||E/F Models: 2 kHz,<br>Y Models: 25 Hz|E/F Models: 1.5 kHz,<br>Y Models: 25 Hz|E/F Models: 600 Hz,<br>Y Models: 25 Hz|E/F Models: 400 Hz,<br>Y Models: 25 Hz| |**Power supply voltage**<br>**(operating voltage**<br>**range)**||E/F Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.<br>Y Models: 24 to 240 VAC (20 to 264 VAC)|||| |**Current consumption**||E/F Models: 17 mA max.|||| |**Leakage current**||Y Models: 1.7 mA max. at 200 VAC (Refer to_Engineering Data_on page 3.)|||| |**Control**<br>**output**|**Load**<br>**current**|E/F Models: 200 mA max.<br>Y Models: 5 to 100 mA||E/F Models: 200 mA max.<br>Y Models: 5 to 300 mA|| ||**Residual**<br>**voltage**|E/F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m)<br>Y Models: Refer to_Engineering Data_on page 3.|||| |**Indicators**||E1 Models: Detection indicator (red), E2/F1/F2 Models: Operation indicator (red)<br>Y Models: Operation indicator (red)|||| |**Operation mode**<br>**(with sensing object**<br>**approaching)**||E1/F1/Y1 Models: NO<br>E2/F2/Y2 Models: NC<br>Refer to the timing charts under_I/O Circuit Diagrams_on page 4 for details.|||| |**Protection circuits**||E/F Models: Reverse polarity protection, Load short-circuit protection, Surge suppressor; Y Models: None|||| |**Ambient**<br>**temperature range**||Operating/Storage:−25 to 70°C (with no icing or condensation)|||| |**Ambient**<br>**humidity range**||Operating/Storage: 35% to 95%|||| |**Temperature influence**||±10% max. of sensing distance at 23°C in the temperature range of−25 to 70°C|||| |**Voltage influence**||E/F Models:±2.5% max. of sensing distance at rated voltage in rated voltage±15% range<br>Y Models:±1% max. of sensing distance at rated voltage in rated voltage±10% range|||| |**Insulation resistance**||50 MΩmin. (at 500 VDC) between current-carrying parts and case|||| |**Dielectric strength**||E/F Models:<br>1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case<br>Y Models: (M8 Models): 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case<br>(Other M8 Models):<br>4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case|||| |**Vibration resistance**||Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions|||| |**Shock resistance**||Destruction: 1,000 m/s210 times each in X, Y, and Z directions|||| |**Degree of protection**||IEC 60529 IP68, in-house standards: oil-resistant *2|||| |**Connection method**||Pre-wired Models (Standard cable length: 2 m)|||| |**Weight (packed state)**||Approx. 40 g|Approx. 50 g|Approx. 130 g|Approx. 170 g| |**Materials**|**Case**|Polyarylate resin|||| ||**Sensing**<br>**surface**||||| ||**Clamping**<br>**nuts**|Polyacetal|||| |**Accessories**||Instruction manual|||| - *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. - *2. When using the Sensor in environments subject to splashing cutting oil, deterioration may result due to the additives in the oil. The E2E is recommended in such environments. ## **OMRON Test Method** Usage conditions: 10 m or less under water in natural conditions 1. No water ingress after 1 hour under water at 2 atmospheres of pressure. 2. Sensing distance and insulation resistance specifications must be met after 20 repetitions of 1 hour in 0 ° C water and 1 hour in 70 ° C water. **==> picture [539 x 34] intentionally omitted <==** **2** **E2F** **Engineering Data (Reference Value)** ## **Sensing Area** ## **E2F-X1R5** @@ **/-X2** @@ ## **E2F-X5** @@ **/-X10** @@ **Leakage Current** **E2F-X** @ **Y** @ **==> picture [511 x 657] intentionally omitted <==** **----- Start of picture text -----**<br> 2.0<br>Protective resistance<br>2 10 mA<br>E2F-X2 E2F-X10<br>[V]<br>Proximity AC power<br>Sensor (OFF) 50/60 Hz<br>E2F-X1R5 1.5<br>E2F-X5<br>1 5<br>1.0<br>0−6 −4 −2 0 2 4 6 0−15 −10 −5 0 5 10 15 0 50 100 150 200 250<br>E 2F-X1R5 Sensing Head E2F-X5 Sensing Head Power supply voltage (V)<br>E 2F-X2 Sensing Head E2F-X10 Sensing Head<br>Distance Y (mm) Distance Y (mm)<br>Influence of Sensing Object Size and Material<br>E2F-X1R5 @@ E2F-X2 @@<br>2.5 d d× t = 1 mm 2.4 2.2 d d× t = 1 mm<br>X X Iron<br>2<br>2.0<br>1.8<br>Stainless steel<br>Iron 1.6 (SUS304)<br>1.5 1.4<br>Stainless steel 1.2<br>(SUS304)<br>1.0 1<br>Brass<br>0.8<br>Brass<br>0.6<br>0.5 Aluminum Aluminum<br>0.4<br>0.2<br>0 5 10 15 20 25 0 5 10 15 20 25<br>Side length of sensing object: d (mm) Side length of sensing object: d (mm)<br>E2F-X5 @@ E2F-X10 @@<br>7 d d× t = 1 mm 1211 d d× t = 1 mm<br>6 X 10 X Iron<br>Iron 9<br>5<br>8<br>Stainless steel (SUS304)<br>4 7<br>Stainless steel (SUS304)<br>6<br>3 5<br>Brass<br>Brass 4<br>2<br>3<br>Aluminum Aluminum<br>1 2<br>1<br>0 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60<br>Side length of sensing object: d (mm) Side length of sensing object: d (mm)<br>Residual Output Voltage<br>E2F-X @ Y @ at 24 VAC E2F-X @ Y @ at 100 VAC E2F-X @ Y @ at 200 VAC<br>30 120 240<br>Residual output voltage Residual output voltage<br>25 100 200<br>ON ON<br>20 Residual Output 80 160<br>Voltage ON V V<br>15 60 VL 120 VL<br>V A 100 VAC A 200 VAC<br>10 40 80<br>VL<br>24 VAC<br>A<br>5 20 40<br>Residual Residual Residual<br>Load load load<br>Voltage OFF voltage OFF voltage OFF<br>0 0<br>1 3 5 10 30 50 100 300 500 01 3 5 10 30 50 100 300 500 1 3 5 10 30 50 100 300 500<br>Load current (mA) Load current (mA) Load current (mA)<br>Distance X (mm) Distance X (mm) Leakage current (mA)<br>Distance X (mm) Distance X (mm)<br>Distance X (mm) Distance X (mm)<br>Load voltage VL (V) Load voltage VL (V) Load voltage VL (V)<br>Y<br>X<br>Y<br>X<br>**----- End of picture text -----**<br> **==> picture [539 x 34] intentionally omitted <==** **3** **E2F** ## **I/O Circuit Diagrams** **==> picture [511 x 706] intentionally omitted <==** **----- Start of picture text -----**<br> Output con-figuration Operation mode Model Timing chart Output circuit<br>E2F-X1R5E@<br>Brown<br>+V<br>Sensing object Present 330 Ω<br>Not present Load<br>NO E2F-X1R5E1E2F-X2E1E2F-X5E1E2F-X10E1 Load (between brown and black leads)Output voltage (between black and blue leads) Operate Reset HighLow Proximity Sensor circuitmain 4.7 kΩ Output Black*2*1 Tr<br>ON<br>Detection indicator (red) OFF Blue 0 V<br>*1. Load current: 200 mA max.<br>DC 3-wire *2. When a transistor is connected.<br>NPN<br>Except the E2F-X1R5E@.<br>Brown<br>+V<br>100 Ω<br>Present<br>Sensing object Load<br>Not present<br>NC E2F-X1R5E2E2F-X2E2E2F-X5E2E2F-X10E2 Load (between brown and black leads)Output voltage (between black and blue leads) OperateReset High Low Proximity Sensor circuitmain 4.7 kΩ2.2 Ω BlackOutput *2*1 Tr<br>Detection indicator (red) OFFON Blue 0 V<br>*1. Load current: 200 mA max.<br>*2. When a transistor is connected.<br>E2F-X1R5F@<br>Brown<br>+V<br>Sensing object Present<br>Not present<br>NO E2F-X1R5F1E2F-X2F1E2F-X5F1E2F-X10F1 Load (between blue and black leads)Output voltage (between black and blue leads) OperateResetHighLow Proximity Sensor circuitmain Output Black*1*2 Tr<br>4.7 kΩ Load<br>ON<br>Detection indicator (red) OFF 330 Ω Blue 0 V<br>*1. Load current: 200 mA max.<br>DC 3-wire *2. When a transistor is connected.<br>PNP<br>Except the E2F-X1R5F@.<br>Brown<br>+V<br>Present<br>Sensing object<br>Not present Tr<br>E2F-X1R5F2 Load (between blue Operate Proximity *2<br>NC E2F-X2F2E2F-X5F2E2F-X10F2 and black leads)Output voltage (between black and blue leads) ResetHighLow Sensor circuitmain 4.7 kΩ 2.2 Ω BlackOutput *1 Load<br>Detection indicator (red) ON 100 Ω Blue<br>OFF 0 V<br>*1. Load current: 200 mA max.<br>*2. When a transistor is connected.<br>E2F-X1R5Y1 Sensing object Present<br>Not present<br>E2F-X2Y1<br>NO E2F-X5Y1 Load Operate<br>Reset Brown<br>E2F-X10Y1 Load<br>Operation ON<br>indicator (red)<br>OFF<br>Proximity<br>AC 2-wire Sensor main<br>circuit<br>E2F-X1R5Y2 Sensing object Present Blue<br>Not present<br>E2F-X2Y2<br>NC E2F-X5Y2 Load Operate<br>Reset<br>E2F-X10Y2<br>Operation indicator ON<br>(red) OFF<br>**----- End of picture text -----**<br> **==> picture [539 x 34] intentionally omitted <==** **4** **E2F** ## **Safety Precautions** ## **Refer to** _**Warranty and Limitations of Liability**_ **.** ## **WARNING** **This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes.** ## **Precautions for Correct Use** Do not use this product under ambient conditions that exceed the ratings. ## ● **Design** ## **Influence of Surrounding Metal** When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the Sensor. ## ● **Mounting** Do not tighten the nut with excessive force. |**Model**|**Torque**| |---|---| |**E2F-X1R5**@@|0.78 N·m| |**E2F-X2**@@|| |**E2F-X5**@@|2 N·m| |**E2F-X10**@@|| ## ● **Maintenance and Inspection** Do not use AC 2-Wire Models in water or in locations subject to water if the sensing surface or any other part of the Sensor is damaged, e.g., from contact with the sensing object. Electric shock may result. **==> picture [242 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> l<br>φd n<br>m<br>D<br>m l<br>Influence of Surrounding Metal (Unit: mm)<br>**----- End of picture text -----**<br> |**Model**<br>**Item**|**l**|**d**|**D**|**m**|**n**|| |---|---|---|---|---|---|---| |**E2F-X1R5**@@|0|8|0|4.5|12|| |**E2F-X2**@@||12||8|18|| |**E2F-X5**@@||18||20|27|| |**E2F-X10**@@||30||40|45|| ## **Mutual Interference** When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. |**Mutual Interference**<br>(Unit: mm)<br>A<br>B|**Mutual Interference**<br>(Unit: mm)<br>A<br>B|**Mutual Interference**<br>(Unit: mm)<br>A<br>B| |---|---|---| |**Model**<br>**Item**|**A**|**B**| |**E2F-X1R5**@@|20|15| |**E2F-X2**@@|30 (20)|20 (12)| |**E2F-X5**@@|50 (30)|35 (18)| |**E2F-X10**@@|100 (50)|70 (35)| Note: Values in parentheses apply to Sensors operating at different frequencies. Models numbers for Sensors with different frequencies are E2F-X@@@5. **==> picture [539 x 34] intentionally omitted <==** **5** **E2F** (Unit: mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. ## **Dimensions** **==> picture [511 x 621] intentionally omitted <==** **----- Start of picture text -----**<br> DC 3-Wire Models AC 2-Wire Models<br>E2F-X1R5E @/-X1R5F@ E2F-X1R5Y @<br>30 40<br>15 dia. 22 15 dia. 32<br>13 20 13 29<br>* *<br>M8 × 1 Detection indicator (red) M8 × 1 Operation indicator (red)<br>4 Two clamping nuts 4 Two clamping nuts<br>Two washers Two washers<br>* 3.5-dia. vinyl-insulated round cable with 3 * 3.5-dia. vinyl-insulated round cable with 2<br>conductors (Conductor cross section: 0.14 mm [2] , conductors (Conductor cross section: 0.14 mm [2] ,<br>Insulator diameter: 1 mm), Standard length: 2 m Insulator diameter: 1 mm), Standard length: 2 m<br>The cable can be extended up to 200 m The cable can be extended up to 200 m<br>(separate metal conduit). (separate metal conduit).<br>E2F-X2E @/-X2F@ E2F-X2Y @<br>38 43<br>27 32<br>17 24 17 29<br>* *<br>M12 × 1 Detection indicator (red) M12 × 1 Operation indicator (red)<br>4 Two clamping nuts 4 Two clamping nuts<br>* 6-dia. vinyl-insulated round cable with 3 conductors (Conductor * 6-dia. vinyl-insulated round cable with 2 conductors (Conductor<br>cross section: 0.5 mm [2] , Insulator diameter: 1.9 mm), Standard cross section: 0.5 mm [2] , Insulator diameter: 1.9 mm), Standard<br>length: 2 m length: 2 m<br>The cable can be extended up to 200 m (separate metal conduit). The cable can be extended up to 200 m (separate metal conduit).<br>E2F-X5E @/-X5F@ E2F-X5Y @<br>47 47<br>40 40<br>32 32<br>24 29 24 29<br>* *<br>M18 × 1 Detection indicator (red) M18 × 1 Operation indicator (red)<br>4 Two clamping nuts 4 Two clamping nuts<br>* 6-dia. vinyl-insulated round cable with 3 conductors (Conductor * 6-dia. vinyl-insulated round cable with 2 conductors (Conductor<br>cross section: 0.5 mm [2] , Insulator diameter: 1.9 mm), Standard cross section: 0.5 mm [2] , Insulator diameter: 1.9 mm), Standard<br>length: 2 m length: 2 m<br>The cable can be extended up to 200 m (separate metal conduit). The cable can be extended up to 200 m (separate metal conduit).<br>E2F-X10E @/-X10F@ E2F-X10Y @<br>57 57<br>50 50<br>41 41<br>36 38 36 38<br>* *<br>Detection indicator (red) Operation indicator (red)<br>M30 × 1.5 M30 × 1.5<br>5 Two clamping nuts 5 Two clamping nuts<br>* 6-dia. vinyl-insulated round cable with 3 conductors (Conductor * 6-dia. vinyl-insulated round cable with 2 conductors (Conductor<br>cross section: 0.5 mm [2] , Insulator diameter: 1.9 mm), Standard cross section: 0.5 mm [2] , Insulator diameter: 1.9 mm), Standard<br>length: 2 m length: 2 m<br>The cable can be extended up to 200 m (separate metal conduit). The cable can be extended up to 200 m (separate metal conduit).<br>**----- End of picture text -----**<br> ## **Mounting Hole Dimensions** **Model E2F-X1R5** @@ **E2F-X2** @@ **E2F-X5** @@ **E2F-X10** @@ **F (mm)** 8.5 +0.50 dia. 12.5 +0.50 dia. 18.5 +0.50 dia. 30.5 +0.50 dia. F **==> picture [539 x 34] intentionally omitted <==** **6** ## Terms and Conditions Agreement ## Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. ## Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. ## Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. ## Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ## Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. ## Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. ## Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. ## Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. **In the interest of product improvement, specifications are subject to change without notice.** ## **OMRON Corporation** ## **Industrial Automation Company** 2017.4 **http://www.ia.omron.com/** (c)Copyright OMRON Corporation 2017 All Right Reserved.
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →