E2EW-QX22B1T30-M1
PROXIMITY SENSOR, 22MM, PNP/SPST-NO, M30
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Inductive Proximity Sensors
- Product Range:E2EW-Q Series; Sensing Range Max:22mm; Sensor Output Type:PNP / SPST-NO; Supply Voltage DC Max:30V; Supply Voltage DC Min:10V; Thread Size - Met 38AJ5402
- Sensor Type: Inductive Proximity Sensor
- Product Range: E2EW-Q Series
- Sensing Distance Nom: 22mm
- Sensor Case / Package: Cylindrical M30 Thread
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 249.93 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Welding Proximity Sensor E2EW Series DC 3-wire** ## **Stable detection in lines containing both aluminum and iron** - Equivalent sensing distances for both iron and aluminum[1] - Enables common design for lines with both iron and aluminum[1] - The exceptional sensing range[2] , which means fewer false detections and thereby fewer unexpected stoppages. - OMRON’s unique fluororesin coating technologies enable longlasting spatter resistance[4] , eliminates the need to replace for 10 years[3] . - Durable full metal body to reduce unexpected downtime - 2-output (NO+NC) models and models with IO-Link[1] are also available. - Laser printed information (sensing distance on the sensor head, model on the cable, and model on the metal part of the connector model) reduce errors during sensor replacement.[5] For the most recent information on models that have been certified for safety standards, refer to your OMRON website. - Weld field immunity cancels pulse noise from magnetic fields.[1] - UL certification (UL60947-5-2) and CSA certification (CSA C22.2 UL60947-5-2-14) Be sure to read _Safety Precautions_ on page 23. ~~A~~ 1. PREMIUM Models only. 2. Based on November 2020 OMRON investigation. 3. This value assumes that the sensor operates 10 hours a day in an arc welding environment and is cleaned once a month (12 times a year). - If our previous model (E2EF-Q) needs to be replaced once every 3 times it is cleaned, the E2EW-Q Proximity Sensor needs to be replaced once every 180 times it is cleaned. This means that there is no need to replace the E2EW-Q Proximity Sensor for 10 or more years. 4. Models with spatter-resistant coating only. 5. Models without spatter-resistant coating only. ## **E2EW Series Model Number Legend** ## **DC 3-wire** - - E2EW 9 (1) X opooooo (2) (3) (4) (5) (6) (7) (8) |**No.**<br>_|**Type**<br>Seon<br>_|**Code**<br>Seon<br>|**Meaning**| |---|---|---|---| |(1)<br>_|Case<br>Seon<br>_|Blank<br>Seon<br>|Without spatter-resistant coating| |||Q<br>Seon<br>|With spatter-resistant coating| |(2)<br>_|Sensing distance<br>_~~J~~<br>ee|Number<br>~~J~~<br>eee|Sensing distance (Unit: mm)| |(3)<br>|Output configuration<br>~~J~~<br>ee|B<br>~~J~~<br>eee|PNP open collector| |||C<br>~~J~~<br>eee|NPN open collector| |(4)|Operation mode<br>ee <br>a4<br>oo|1<br> eee<br>a4|Normally open (NO)| |||2<br>a4|Normally closed (NC)| |||3<br>a4<br>oo|Normally open, Normally closed (NO+NC)| |(5)|IO-Link baud rate<br>a4<br>oo<br>a4<br>oo<br>|Blank<br>a4<br>oo<br>a4|Non IO-Link compliant| |||D<br>a4|COM2 (38.4kbps)| |||T<br>a4<br>oo<br>——|COM3 (230.4kbps)| |(6)|Size<br>a4<br>oo<br>—<br>a<br>oo|12<br>a4<br>oo<br>—<br>——|M12| |||18<br>—<br>——|M18| |||30<br>—<br>——<br>oo|M30| |(7)|Connection method<br>—<br>a <br>oo<br>a4<br>oo|Blank<br>—<br> ——<br>oo<br>a4|Pre-wired Models| |||M1<br>a4|M12 Connector Models| |||M1TJ<br>a4<br>oo|M12 Pre-wired Smartclick Connector Models| |(8)|Cable length<br>a4<br>oo<br>J|Number M<br>a4<br>oo<br>J|Cable length| **Note:** The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number. Models are not available for all combinations of code numbers. **1** **E2EW Series Ordering Information** ## **PREMIUM Model** ## **E2EW Series (Quadruple distance model)** ## **DC 3-wire [Refer to** _**Dimensions**_ **on page 26.] Shielded[1]** |**Size**<br>**(Sensing distance)**|**Connection method**|**Operation mode**|**Model**|**Model**| |---|---|---|---|---| ||||**PNP**|**NPN**| |M12<br>(7 mm)|Pre-wired (2 m)2|NO|**E2EW-X7B1T12 2M**|**E2EW-X7C112 2M**| |||NC|**E2EW-X7B212 2M**|**E2EW-X7C212 2M**| |||NO+NC|**E2EW-X7B3T12 2M**|**E2EW-X7C312 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X7B1T12-M1TJ 0.3M**|**E2EW-X7C112-M1TJ 0.3M**| |||NC|**E2EW-X7B212-M1TJ 0.3M**|**E2EW-X7C212-M1TJ 0.3M**| |||NO+NC|**E2EW-X7B3T12-M1TJ 0.3M**|**E2EW-X7C312-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-X7B1T12-M1**|**E2EW-X7C112-M1**| |||NC|**E2EW-X7B212-M1**|**E2EW-X7C212-M1**| |||NO+NC|**E2EW-X7B3T12-M1**|**E2EW-X7C312-M1**| |M18<br>(12 mm)|Pre-wired (2 m)2|NO|**E2EW-X12B1T18 2M**|**E2EW-X12C118 2M**| |||NC|**E2EW-X12B218 2M**|**E2EW-X12C218 2M**| |||NO+NC|**E2EW-X12B3T18 2M**|**E2EW-X12C318 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X12B1T18-M1TJ 0.3M**|**E2EW-X12C118-M1TJ 0.3M**| |||NC|**E2EW-X12B218-M1TJ 0.3M**|**E2EW-X12C218-M1TJ 0.3M**| |||NO+NC|**E2EW-X12B3T18-M1TJ 0.3M**|**E2EW-X12C318-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-X12B1T18-M1**|**E2EW-X12C118-M1**| |||NC|**E2EW-X12B218-M1**|**E2EW-X12C218-M1**| |||NO+NC|**E2EW-X12B3T18-M1**|**E2EW-X12C318-M1**| |M30<br>(22 mm)|Pre-wired (2 m)2|NO|**E2EW-X22B1T30 2M**|**E2EW-X22C130 2M**| |||NC|**E2EW-X22B230 2M**|**E2EW-X22C230 2M**| |||NO+NC|**E2EW-X22B3T30 2M**|**E2EW-X22C330 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X22B1T30-M1TJ 0.3M**|**E2EW-X22C130-M1TJ 0.3M**| |||NC|**E2EW-X22B230-M1TJ 0.3M**|**E2EW-X22C230-M1TJ 0.3M**| |||NO+NC|**E2EW-X22B3T30-M1TJ 0.3M**|**E2EW-X22C330-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-X22B1T30-M1**|**E2EW-X22C130-M1**| |||NC|**E2EW-X22B230-M1**|**E2EW-X22C230-M1**| |||NO+NC|**E2EW-X22B3T30-M1**|**E2EW-X22C330-M1**| 1. When embedding the Proximity Sensor in metal, refer to _Influence of Surrounding Metal_ on page 24. 2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-X7B1T12 5M) - **Note: 1.** Models in are equipped with IO-Link (COM3). For IO-Link (COM2), select a model number with the format of "E2EW-XD" (Example ~~: E2EW-X~~ 7B1D12 2M). Operation mode NO can be changed to NC via IO-Link communications. **2.** IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. **2** **E2EW Series** ## **PREMIUM Model** ## **E2EW Series (Triple distance model)** ## **DC 3-wire [Refer to** _**Dimensions**_ **on page 26.] Shielded[1]** |**Size**<br>**(Sensing distance)**|**Connection method**|**Operation mode**|**Model**|**Model**| |---|---|---|---|---| ||||**PNP**|**NPN**| |M12<br>(6 mm)|Pre-wired (2 m)2|NO|**E2EW-X6B1T12 2M**|**E2EW-X6C112 2M**| |||NC|**E2EW-X6B212 2M**|**E2EW-X6C212 2M**| |||NO+NC|**E2EW-X6B3T12 2M**|**E2EW-X6C312 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X6B1T12-M1TJ 0.3M**|**E2EW-X6C112-M1TJ 0.3M**| |||NC|**E2EW-X6B212-M1TJ 0.3M**|**E2EW-X6C212-M1TJ 0.3M**| |||NO+NC|**E2EW-X6B3T12-M1TJ 0.3M**|**E2EW-X6C312-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-X6B1T12-M1**|**E2EW-X6C112-M1**| |||NC|**E2EW-X6B212-M1**|**E2EW-X6C212-M1**| |||NO+NC|**E2EW-X6B3T12-M1**|**E2EW-X6C312-M1**| |M18<br>(10 mm)|Pre-wired (2 m)2|NO|**E2EW-X10B1T18 2M**|**E2EW-X10C118 2M**| |||NC|**E2EW-X10B218 2M**|**E2EW-X10C218 2M**| |||NO+NC|**E2EW-X10B3T18 2M**|**E2EW-X10C318 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X10B1T18-M1TJ 0.3M**|**E2EW-X10C118-M1TJ 0.3M**| |||NC|**E2EW-X10B218-M1TJ 0.3M**|**E2EW-X10C218-M1TJ 0.3M**| |||NO+NC|**E2EW-X10B3T18-M1TJ 0.3M**|**E2EW-X10C318-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-X10B1T18-M1**|**E2EW-X10C118-M1**| |||NC|**E2EW-X10B218-M1**|**E2EW-X10C218-M1**| |||NO+NC|**E2EW-X10B3T18-M1**|**E2EW-X10C318-M1**| |M30<br>(20 mm)|Pre-wired (2 m)2|NO|**E2EW-X20B1T30 2M**|**E2EW-X20C130 2M**| |||NC|**E2EW-X20B230 2M**|**E2EW-X20C230 2M**| |||NO+NC|**E2EW-X20B3T30 2M**|**E2EW-X20C330 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X20B1T30-M1TJ 0.3M**|**E2EW-X20C130-M1TJ 0.3M**| |||NC|**E2EW-X20B230-M1TJ 0.3M**|**E2EW-X20C230-M1TJ 0.3M**| |||NO+NC|**E2EW-X20B3T30-M1TJ 0.3M**|**E2EW-X20C330-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-X20B1T30-M1**|**E2EW-X20C130-M1**| |||NC|**E2EW-X20B230-M1**|**E2EW-X20C230-M1**| |||NO+NC|**E2EW-X20B3T30-M1**|**E2EW-X20C330-M1**| 1. When embedding the Proximity Sensor in metal, refer to _Influence of Surrounding Metal_ on page 24. 2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-X6B1T12 5M) - **Note: 1.** Models in are equipped with IO-Link (COM3). For IO-Link (COM2), select a model number with the format of "E2EWXD ~~" (Exam~~ ple: E2EW-X6B1D12 2M). Operation mode NO can be changed to NC via IO-Link communications. **2.** IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. **3** **E2EW Series** ## **PREMIUM Model** ## **E2EW-Q Series (Spatter-resistant Quadruple distance model) DC 3-wire [Refer to** _**Dimensions**_ **on page 26.] Shielded[1]** |**Size**<br>**(Sensing distance)**|**Connection method**|**Operation mode**|**Model**|**Model**| |---|---|---|---|---| ||||**PNP**|**NPN**| |M12<br>(7 mm)|Pre-wired (2 m)2|NO|**E2EW-QX7B1T12 2M**|**E2EW-QX7C112 2M**| |||NC|**E2EW-QX7B212 2M**|**E2EW-QX7C212 2M**| |||NO+NC|**E2EW-QX7B3T12 2M**|**E2EW-QX7C312 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX7B1T12-M1TJ 0.3M**|**E2EW-QX7C112-M1TJ 0.3M**| |||NC|**E2EW-QX7B212-M1TJ 0.3M**|**E2EW-QX7C212-M1TJ 0.3M**| |||NO+NC|**E2EW-QX7B3T12-M1TJ 0.3M**|**E2EW-QX7C312-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-QX7B1T12-M1**|**E2EW-QX7C112-M1**| |||NC|**E2EW-QX7B212-M1**|**E2EW-QX7C212-M1**| |||NO+NC|**E2EW-QX7B3T12-M1**|**E2EW-QX7C312-M1**| |M18<br>(12 mm)|Pre-wired (2 m)2|NO|**E2EW-QX12B1T18 2M**|**E2EW-QX12C118 2M**| |||NC|**E2EW-QX12B218 2M**|**E2EW-QX12C218 2M**| |||NO+NC|**E2EW-QX12B3T18 2M**|**E2EW-QX12C318 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX12B1T18-M1TJ 0.3M**|**E2EW-QX12C118-M1TJ 0.3M**| |||NC|**E2EW-QX12B218-M1TJ 0.3M**|**E2EW-QX12C218-M1TJ 0.3M**| |||NO+NC|**E2EW-QX12B3T18-M1TJ 0.3M**|**E2EW-QX12C318-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-QX12B1T18-M1**|**E2EW-QX12C118-M1**| |||NC|**E2EW-QX12B218-M1**|**E2EW-QX12C218-M1**| |||NO+NC|**E2EW-QX12B3T18-M1**|**E2EW-QX12C318-M1**| |M30<br>(22 mm)|Pre-wired (2 m)2|NO|**E2EW-QX22B1T30 2M**|**E2EW-QX22C130 2M**| |||NC|**E2EW-QX22B230 2M**|**E2EW-QX22C230 2M**| |||NO+NC|**E2EW-QX22B3T30 2M**|**E2EW-QX22C330 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX22B1T30-M1TJ 0.3M**|**E2EW-QX22C130-M1TJ 0.3M**| |||NC|**E2EW-QX22B230-M1TJ 0.3M**|**E2EW-QX22C230-M1TJ 0.3M**| |||NO+NC|**E2EW-QX22B3T30-M1TJ 0.3M**|**E2EW-QX22C330-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-QX22B1T30-M1**|**E2EW-QX22C130-M1**| |||NC|**E2EW-QX22B230-M1**|**E2EW-QX22C230-M1**| |||NO+NC|**E2EW-QX22B3T30-M1**|**E2EW-QX22C330-M1**| 1. When embedding the Proximity Sensor in metal, refer to _Influence of Surrounding Metal_ on page 24. 2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-QX7B1T12 5M) - **Note: 1.** Models in are equipped with IO-Link (COM3). For IO-Link (COM2), select a model number with the format of "E2EW-QXD" (Example ~~: E2EW-QX~~ 7B1D12 2M). Operation mode NO can be changed to NC via IO-Link communications. **2.** IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. **4** **E2EW Series** ## **PREMIUM Model** ## **E2EW-Q Series (Spatter-resistant Triple distance model)** ## **DC 3-wire [Refer to** _**Dimensions**_ **on page 26.] Shielded[1]** |**Size**<br>**(Sensing distance)**|**Connection method**|**Operation mode**|**Model**|**Model**| |---|---|---|---|---| ||||**PNP**|**NPN**| |M12<br>(6 mm)|Pre-wired (2 m)2|NO|**E2EW-QX6B1T12 2M**|**E2EW-QX6C112 2M**| |||NC|**E2EW-QX6B212 2M**|**E2EW-QX6C212 2M**| |||NO+NC|**E2EW-QX6B3T12 2M**|**E2EW-QX6C312 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX6B1T12-M1TJ 0.3M**|**E2EW-QX6C112-M1TJ 0.3M**| |||NC|**E2EW-QX6B212-M1TJ 0.3M**|**E2EW-QX6C212-M1TJ 0.3M**| |||NO+NC|**E2EW-QX6B3T12-M1TJ 0.3M**|**E2EW-QX6C312-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-QX6B1T12-M1**|**E2EW-QX6C112-M1**| |||NC|**E2EW-QX6B212-M1**|**E2EW-QX6C212-M1**| |||NO+NC|**E2EW-QX6B3T12-M1**|**E2EW-QX6C312-M1**| |M18<br>(10 mm)|Pre-wired (2 m)2|NO|**E2EW-QX10B1T18 2M**|**E2EW-QX10C118 2M**| |||NC|**E2EW-QX10B218 2M**|**E2EW-QX10C218 2M**| |||NO+NC|**E2EW-QX10B3T18 2M**|**E2EW-QX10C318 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX10B1T18-M1TJ 0.3M**|**E2EW-QX10C118-M1TJ 0.3M**| |||NC|**E2EW-QX10B218-M1TJ 0.3M**|**E2EW-QX10C218-M1TJ 0.3M**| |||NO+NC|**E2EW-QX10B3T18-M1TJ 0.3M**|**E2EW-QX10C318-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-QX10B1T18-M1**|**E2EW-QX10C118-M1**| |||NC|**E2EW-QX10B218-M1**|**E2EW-QX10C218-M1**| |||NO+NC|**E2EW-QX10B3T18-M1**|**E2EW-QX10C318-M1**| |M30<br>(20 mm)|Pre-wired (2 m)2|NO|**E2EW-QX20B1T30 2M**|**E2EW-QX20C130 2M**| |||NC|**E2EW-QX20B230 2M**|**E2EW-QX20C230 2M**| |||NO+NC|**E2EW-QX20B3T30 2M**|**E2EW-QX20C330 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX20B1T30-M1TJ 0.3M**|**E2EW-QX20C130-M1TJ 0.3M**| |||NC|**E2EW-QX20B230-M1TJ 0.3M**|**E2EW-QX20C230-M1TJ 0.3M**| |||NO+NC|**E2EW-QX20B3T30-M1TJ 0.3M**|**E2EW-QX20C330-M1TJ 0.3M**| ||M12 Connector|NO|**E2EW-QX20B1T30-M1**|**E2EW-QX20C130-M1**| |||NC|**E2EW-QX20B230-M1**|**E2EW-QX20C230-M1**| |||NO+NC|**E2EW-QX20B3T30-M1**|**E2EW-QX20C330-M1**| 1. When embedding the Proximity Sensor in metal, refer to _Influence of Surrounding Metal_ on page 24. 2. Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-QX6B1T12 5M) - **Note: 1.** Models in are equipped with IO-Link (COM3). For IO-Link (COM2), select a model number with the format of "E2EW-QXD" (Example: ~~E2EW-QX~~ 6B1D12 2M). Operation mode NO can be changed to NC via IO-Link communications. **2.** IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. **5** **E2EW Series** ## **BASIC Model** ## **E2EW Series (Single distance model)** ## **DC 3-wire [Refer to** _**Dimensions**_ **on page 27.] Shielded** |**Size**<br>**(Sensing distance)**|**Connection method**|**Operation mode**|**Model**|**Model**| |---|---|---|---|---| ||||**PNP**|**NPN**| |M12<br>(2 mm)|Pre-wired (2 m)*|NO|**E2EW-X2B112 2M**|**E2EW-X2C112 2M**| |||NC|**E2EW-X2B212 2M**|**E2EW-X2C212 2M**| |||NO+NC|**E2EW-X2B312 2M**|**E2EW-X2C312 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X2B112-M1TJ 0.3M**|**E2EW-X2C112-M1TJ 0.3M**| |||NC|**E2EW-X2B212-M1TJ 0.3M**|**E2EW-X2C212-M1TJ 0.3M**| |||NO+NC|**E2EW-X2B312-M1TJ 0.3M**|**E2EW-X2C312-M1TJ 0.3M**| |M18<br>(5 mm)|Pre-wired (2 m)*|NO|**E2EW-X5B118 2M**|**E2EW-X5C118 2M**| |||NC|**E2EW-X5B218 2M**|**E2EW-X5C218 2M**| |||NO+NC|**E2EW-X5B318 2M**|**E2EW-X5C318 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X5B118-M1TJ 0.3M**|**E2EW-X5C118-M1TJ 0.3M**| |||NC|**E2EW-X5B218-M1TJ 0.3M**|**E2EW-X5C218-M1TJ 0.3M**| |||NO+NC|**E2EW-X5B318-M1TJ 0.3M**|**E2EW-X5C318-M1TJ 0.3M**| |M30<br>(10 mm)|Pre-wired (2 m)*|NO|**E2EW-X10B130 2M**|**E2EW-X10C130 2M**| |||NC|**E2EW-X10B230 2M**|**E2EW-X10C230 2M**| |||NO+NC|**E2EW-X10B330 2M**|**E2EW-X10C330 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-X10B130-M1TJ 0.3M**|**E2EW-X10C130-M1TJ 0.3M**| |||NC|**E2EW-X10B230-M1TJ 0.3M**|**E2EW-X10C230-M1TJ 0.3M**| |||NO+NC|**E2EW-X10B330-M1TJ 0.3M**|**E2EW-X10C330-M1TJ 0.3M**| * Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-X2B112 5M) **Note:** IO-Link is not supported for all types of BASIC Model. **6** **E2EW Series** ## **BASIC Model** ## **E2EW-Q Series (Spatter-resistant Single distance model) DC 3-wire [Refer to** _**Dimensions**_ **on page 27.] Shielded** |**Size**<br>**(Sensing distance)**|**Connection method**|**Operation mode**|**Model**|**Model**| |---|---|---|---|---| ||||**PNP**|**NPN**| |M12<br>(2 mm)|Pre-wired (2 m)*|NO|**E2EW-QX2B112 2M**|**E2EW-QX2C112 2M**| |||NC|**E2EW-QX2B212 2M**|**E2EW-QX2C212 2M**| |||NO+NC|**E2EW-QX2B312 2M**|**E2EW-QX2C312 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX2B112-M1TJ 0.3M**|**E2EW-QX2C112-M1TJ 0.3M**| |||NC|**E2EW-QX2B212-M1TJ 0.3M**|**E2EW-QX2C212-M1TJ 0.3M**| |||NO+NC|**E2EW-QX2B312-M1TJ 0.3M**|**E2EW-QX2C312-M1TJ 0.3M**| |M18<br>(5 mm)|Pre-wired (2 m)*|NO|**E2EW-QX5B118 2M**|**E2EW-QX5C118 2M**| |||NC|**E2EW-QX5B218 2M**|**E2EW-QX5C218 2M**| |||NO+NC|**E2EW-QX5B318 2M**|**E2EW-QX5C318 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX5B118-M1TJ 0.3M**|**E2EW-QX5C118-M1TJ 0.3M**| |||NC|**E2EW-QX5B218-M1TJ 0.3M**|**E2EW-QX5C218-M1TJ 0.3M**| |||NO+NC|**E2EW-QX5B318-M1TJ 0.3M**|**E2EW-QX5C318-M1TJ 0.3M**| |M30<br>(10 mm)|Pre-wired (2 m)*|NO|**E2EW-QX10B130 2M**|**E2EW-QX10C130 2M**| |||NC|**E2EW-QX10B230 2M**|**E2EW-QX10C230 2M**| |||NO+NC|**E2EW-QX10B330 2M**|**E2EW-QX10C330 2M**| ||M12 Pre-wired<br>Smartclick Connector (0.3 m)|NO|**E2EW-QX10B130-M1TJ 0.3M**|**E2EW-QX10C130-M1TJ 0.3M**| |||NC|**E2EW-QX10B230-M1TJ 0.3M**|**E2EW-QX10C230-M1TJ 0.3M**| |||NO+NC|**E2EW-QX10B330-M1TJ 0.3M**|**E2EW-QX10C330-M1TJ 0.3M**| * Models with 5-m cable length are also available with "5M" suffix. (Example: E2EW-QX2B112 5M) **Note:** IO-Link is not supported for all types of BASIC Model. **7** **E2EW Series** ## **Accessories (Sold Separately)** ## **Sensor I/O Connectors** **(Models for Pre-wired Connectors) A Sensor I/O Connector is not provided with the Sensor. It must be ordered separately as required.** ## **Round Water-resistant Connectors XS2 series** |**Cable**<br>**Specification**|**Type**|**Cable**<br>**diameter**<br>**(mm)**|**Cable Connection**<br>**Direction**|**Cable**<br>**length**<br>**(m)**|**Sensor I/O Connector**<br>**model number**| |---|---|---|---|---|---| |PVC robot cable|Sockets on One<br>Cable End|6 dia.|Straight|2<br>ee|**XS2F-M12PVC4S2M**<br>ee| |||||5<br>ee<br>ee|**XS2F-M12PVC4S5M**<br>ee<br>ee| |||||10<br>ee<br>a|**XS2F-M12PVC4S10M**<br>ee<br>| ||||Right-angle|2<br>aes|**XS2F-M12PVC4A2M**<br>es| |||||5<br>es<br>es|**XS2F-M12PVC4A5M**<br>es<br>es| |||||10<br>es<br>es|**XS2F-M12PVC4A10M**<br>es<br>es| ||Socket and Plug<br>on Cable Ends|6 dia.|Straight (Socket)/<br>Straight (Plug)|1<br>es<br>**es**|**XS2W-D421-C81-F**<br>es<br>**es**<br>e| |||||2<br>**es**|**XS2W-D421-D81-F**<br>**es**<br>e| |||||3<br>**es**|**XS2W-D421-E81-F**<br>**es**<br>e| |||||5<br>ee|**XS2W-D421-G81-F**<br>ee| |||||10<br>ee<br>a|**XS2W-D421-J81-F**<br>ee| ||||Right-angle (Socket)/<br>Right-angle (Plug)<br>eee|2<br>a<br>eee|**XS2W-D422-D81-F**<br>eee| |||||5<br>eee|**XS2W-D422-G81-F**<br>eee<br>pT| ||||Straight (Socket)/<br>Right-angle (Plug)<br>eee|2<br>eee|**XS2W-D423-D81-F**<br>eee<br>pT| |||||5|**XS2W-D423-G81-F**| ||||Right-angle (Socket)/<br>Straight (Plug)<br>—|2<br>ee|**XS2W-D424-D81-F**<br>ee| |||||5<br> ee|**XS2W-D424-G81-F**<br>ee| **8** **E2EW Series** ## **Ratings and Specifications** ## **PREMIUM Model** ## **E2EW Series (Quadruple/Triple distance model) E2EW-Q Series (Spatter-resistant Quadruple/Triple distance model)** ## **DC 3-wire** ## **Shielded** |**Type**|**Type**|**Quadruple distance model**|**Quadruple distance model**|**Quadruple distance model**|**Triple distance model**|**Triple distance model**|**Triple distance model**| |---|---|---|---|---|---|---|---| |**Size**||**M12**|**M18**|**M30**|**M12**|**M18**|**M30**| |**Item**<br>**Model**||**E2EW-(Q)X7****12**|**E2EW-(Q)X12****18**|**E2EW-(Q)X22****30**|**E2EW-(Q)X6****12**|**E2EW-(Q)X10****18**|**E2EW-(Q)X20****30**| |**Sensing distance**||7 mm ±10%|12 mm ±10%|22 mm ±10%|6 mm ±10%|10 mm ±10%|20 mm ±10%| |**Setting distance**||0 to 4.9 mm|0 to 8.4 mm|0 to 15.4 mm|0 to 4.2 mm|0 to 7.0 mm|0 to 14 mm| |**Differential travel**||15% max. of sensing distance|||||| |**Detectable object**||Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer to<br>_Engineering Data_on page 11.)|||||| |**Standard sensing object**||Iron,<br>21 × 21 × 1 mm|Iron,<br>36 × 36 × 1 mm|Iron,<br>66 × 66 × 1 mm|Iron,<br>18 × 18 × 1 mm|Iron,<br>30 × 30 × 1 mm|Iron,<br>60 × 60 × 1 mm| |**Response frequency1**||2 Hz|||||| |**Power supply voltage**||10 to 30 VDC (including 10% ripple (p-p)), Class 2|||||| |**Current consumption**||720 mW max. (Current consumption: 30 mA max. at power supply voltage of 24 V)|||||| |**Output configuration**||B Models: PNP open collector, C Models: NPN open collector|||||| |**Operation mode**||1-output models (B1, C1): NO (Normally open),<br>1-output models (B2, C2): NC (Normally closed),<br>2-output models (B3, C3): NO+NC (Normally open, Normally closed)|||||| |**Control output**|**Load current**|1-output models (B1,B2,C1,C2): 10 to 30 VDC, Class 2, 200 mA max.<br>2-output models (B3, C3): 10 to 30 VDC, Class 2, 100 mA max.|||||| ||**Residual voltage**|1-output models (B1,B2,C1,C2): 2 V max. (Load current: 200 mA, Cable length: 2 m)<br>2-output models (B3, C3): 2 V max. (Load current: 100 mA, Cable length: 2 m)|||||| |**Indicator**||In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit)<br>In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green,<br>blinking at 1 s intervals)|||||| |**Protection circuits**||Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection|||||| |**Ambient temperature range**||Operating: 0 to 85 °C, Storage: -15 to 85 °C (with no icing or condensation)**3**|||||| |**Ambient humidity range**||Operating/Storage: 35% to 95% (with no condensation)|||||| |**Temperature influence**||±20% max. of sensing distance at 23 °C in the temperature range of 0 to 85 °C|||||| |**Voltage influence**||±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range|||||| |**Insulation resistance**||50 Mmin. (at 500 VDC) between current-carrying parts and case|||||| |**Dielectric strength**||1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case|||||| |**Vibration resistance (destruction)**||10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions|||||| |**Shock resistance (destruction)**||1,000 m/s210 times each in X, Y, and Z directions|||||| |**Degree of protection**||IEC 60529: IP67|||||| |**Connection method**||Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m),<br>M12 Connector Models|||||| |**Weight**<br>**(packed state)**|**Pre-wired**|Approx. 140 g|Approx. 165 g|Approx. 225 g|Approx. 140 g|Approx. 165 g|Approx. 225 g| ||**M12 Pre-wired**<br>**Smartclick**<br>**Connector**|Approx. 70 g|Approx. 100 g|Approx. 160 g|Approx. 70 g|Approx. 100 g|Approx. 160 g| ||**M12 Connector**|Approx. 60 g|Approx. 75 g|Approx. 135 g|Approx. 60 g|Approx. 75 g|Approx. 135 g| |**Materials**|**Case**|E2EW-X:Stainless steel (SUS303), E2EW-QX:Fluororesin coating (Base material: (SUS303))|||||| ||**Sensing surface**|E2EW-X:Stainless steel (SUS303), E2EW-QX:Fluororesin coating (Base material: (SUS303))|||||| ||**Sensing surface**<br>**(Thickness)**|0.4 mm|0.4 mm|0.5 mm|0.4 mm|0.4 mm|0.5 mm| ||**Clamping nuts**|E2EW-X:Stainless steel (SUS303), E2EW-QX:Fluororesin coating (Base material: (SUS303))|||||| ||**Toothed washers**|Zinc-plated iron|||||| ||**Cable**|Vinyl chloride (PVC)|||||| |**Main IO-Link functions2**||Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting,<br>timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting<br>function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset|||||| |**IO-Link**<br>**Communication**<br>**specifications2**|**IO-Link**<br>**specification**|Ver.1.1|||||| ||**Baud rate**|E2EW(-Q) XBT: COM3 (230.4 kbps), E2EW(-Q) XBD: COM2 (38.4 kbps)|||||| ||**Data length**|PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2)|||||| ||**Minimum cycle**<br>**time**|COM2: 2.3 ms, COM3: 1.0 ms|||||| |**Accessories**||Instruction manual, Clamping nuts, Toothed washer|||||| 1. The response frequency is an average value. Factory setting: (timer function: ONOFF delay) 2. IO-Link is not supported for NC-type PNP outputs or all types of NPN outputs. 3. UL temperature rating is between 0 °C to 60 °C. **9** **E2EW Series** ## **BASIC Model** ## **E2EW Series (Single distance model) E2EW-Q Series (Spatter-resistant Single distance model)** ## **DC 3-wire** ## **Shielded** |**Type**|**Type**|**Single distance model**|**Single distance model**|**Single distance model**| |---|---|---|---|---| |**Size**||**M12**|**M18**|**M30**| |**Item**<br>**Model**||**E2EW-(Q)X2****12**|**E2EW-(Q)X5****18**|**E2EW-(Q)X10****30**| |**Sensing distance**||2 mm ±10%|5 mm ±10%|10 mm ±10%| |**Setting distance**||0 to 1.4 mm|0 to 3.5 mm|0 to 7 mm| |**Differential travel**||10% max. of sensing distance||| |**Detectable object**||Ferrous metals and non-ferrous metals (The sensing distance depends on the material of the sensing object. Refer<br>to_Engineering Data_on page 11.)||| |**Standard sensing object**||Iron,<br>12 × 12 × 1 mm|Iron,<br>18 × 18 × 1 mm|Iron,<br>30 × 30 × 1 mm| |**Response frequency1**||100 Hz|80 Hz|40 Hz| |**Power supply voltage**||10 to 30 VDC (including 10% ripple (p-p)), Class 2||| |**Current consumption**||1-output models (B1, B2, C1, C2): 16 mA max.<br>2-output models (B3, C3): 20 mA max.||| |**Output configuration**||B Models: PNP open collector,<br>C Models: NPN open collector||| |**Operation mode**||1-output models (B1, C1): NO (Normally open),<br>1-output models (B2, C2): NC (Normally closed),<br>2-output models (B3, C3): NO+NC (Normally open, Normally closed)||| |**Control output**|**Load current**|1-output models (B1, B2, C1, C2): 10 to 30 VDC, Class 2, 200 mA max.<br>2-output models (B3, C3): 10 to 30 VDC, Class 2, 100 mA max.||| ||**Residual voltage**|1-output models (B1, B2, C1, C2): 2 V max. (Load current: 200 mA, Cable length: 2 m)<br>2-output models (B3, C3): 2 V max. (Load current: 100 mA, Cable length: 2 m)||| |**Indicator**||Operation indicator (orange, lit) and communication indicator (green, not lit)||| |**Protection circuits**||Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity<br>protection||| |**Ambient temperature range**||Operating: 0 to 85 °C, Storage: -15 to 85 °C (with no icing or condensation) **2**||| |**Ambient humidity range**||Operating/Storage: 35% to 95% (with no condensation)||| |**Temperature influence**||±20% max. of sensing distance at 23 °C in the temperature range of 0 to 85 °C||| |**Voltage influence**||±1.5% max. of sensing distance at rated voltage in the rated voltage ±15% range||| |**Insulation resistance**||50 Mmin. (at 500 VDC) between current-carrying parts and case||| |**Dielectric strength**||1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case||| |**Vibration resistance (destruction)**||10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions||| |**Shock resistance (destruction)**||1,000 m/s210 times each in X, Y, and Z directions||| |**Degree of protection**||IEC 60529: IP67||| |**Connection method**||Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m)||| |**Weight**<br>**(packed state)**|**Pre-wired**|Approx. 140 g|Approx. 160 g|Approx. 225 g| ||**M12 Pre-wired Smartclick**<br>**Connector**|Approx. 70 g|Approx. 95 g|Approx. 160 g| |**Materials**|**Case**|E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303))||| ||**Sensing surface**|E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303))||| ||**Sensing surface**<br>**(Thickness)**|0.8 mm|0.8 mm|0.8 mm| ||**Clamping nuts**|E2EW-X: Stainless steel (SUS303), E2EW-QX: Fluororesin coating (Base material: (SUS303))||| ||**Toothed washers**|Zinc-plated iron||| ||**Cable**|Vinyl chloride (PVC)||| |**Accessories**||Instruction manual, Clamping nuts, Toothed washer||| 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2. UL temperature rating is between 0 °C to 60 °C. **10** **E2EW Series** ## **Engineering Data (Reference Value)** ## **Sensing Area** ## **PREMIUM Model** ## **Quadruple distance model/ Spatter-resistant Quadruple distance model Shielded** **==> picture [507 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> Sensing object: iron Sensing object: Aluminum<br>24 24<br>22 22<br>20 20<br>E2EW-(Q)X22@30<br>18 18<br>E2EW-(Q)X22@30<br>16 16<br>14 14<br>12 12<br>108 E2EW-(Q)X12@18 108 E2EW-(Q)X12@18<br>6 6 E2EW-(Q)X7@12<br>4 E2EW-(Q)X7@12 4<br>2 2<br>0 0<br>-35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35<br>Distance Y (mm) Distance Y (mm)<br>Distance X (mm) Distance X (mm)<br>Y<br>X<br>Y<br>X<br>**----- End of picture text -----**<br> ## **Triple distance model/ Spatter-resistant Triple distance model Shielded** **Sensing object: iron** ## **Sensing object: Aluminum** **==> picture [506 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> 24 24<br>22 22<br>20 20<br>18 18 E2EW-(Q)X20@30<br>16 16<br>E2EW-(Q)X20@30<br>14 14<br>12 12<br>10 10<br>8 E2EW-(Q)X10@18 8 E2EW-(Q)X10@18<br>6 6<br>4 E2EW-(Q)X6@12 4 E2EW-(Q)X6@12<br>2 2<br>0 0<br>-35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35<br>Distance Y (mm) Distance Y (mm)<br>Distance X (mm) Distance X (mm)<br>Y<br>X<br>Y<br>X<br>**----- End of picture text -----**<br> ## **BASIC Model** ## **Single distance model/ Spatter-resistant Single distance model Shielded** ## **Sensing object: iron** **==> picture [247 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> 14<br>12<br>10<br>E2EW-(Q)X10@30<br>8<br>6<br>4 E2EW-(Q)X5@18<br>2<br>E2EW-(Q)X2@12<br>0<br>-25 -20 -15 -10 -5 0 5 10 15 20 25<br>Distance Y (mm)<br>Distance X (mm)<br>Y<br>X<br>**----- End of picture text -----**<br> **11** **E2EW Series** ## **Influence of Sensing Object Size and Material** ## **PREMIUM Model** ## **Quadruple distance model/ Spatter-resistant Quadruple distance model Shielded** **Size: M12 E2EW-(Q)X7** **12** **==> picture [202 x 274] intentionally omitted <==** **----- Start of picture text -----**<br> 10<br>Brass Iron<br>8<br>6<br>Aluminum Copper<br>4<br>Stainless steel @d t=3mm<br>(SUS304) X<br>2<br>0<br>0 10 20 30 40 50 60 70 80 90<br>Side length of sensing object: d (mm)<br>Size: M18 E2EW-(Q)X12 18<br>16<br>Brass Iron<br>14<br>12<br>10<br>8 Aluminum Copper<br>6<br>@d<br>4 X t=3mm<br>Stainless steel<br>2 (SUS304)<br>0<br>0 10 20 30 40 50 60 70 80 90<br>Side length of sensing object: d (mm)<br>Distance X (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> ## **Size: M18 E2EW-(Q)X12** **18** ## **Size: M30 E2EW-(Q)X22** **30** **==> picture [204 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> 25<br>Brass Iron<br>20<br>Aluminum<br>15<br>Copper<br>10<br>@d<br>t=3mm<br>Stainless steel X<br>5 (SUS304)<br>0<br>0 10 20 30 40 50 60 70 80 90 100 110 120<br>Side length of sensing object: d (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> ## **Triple distance model/ Spatter-resistant Triple distance model Shielded Size: M12 E2EW--(Q)X6** **12** **==> picture [204 x 421] intentionally omitted <==** **----- Start of picture text -----**<br> 10<br>Brass Iron<br>8<br>6<br>Aluminum Copper<br>4<br>@d<br>Stainless steel X t=3mm<br>2 (SUS304)<br>0<br>0 10 20 30 40 50 60 70 80 90<br>Side length of sensing object: d (mm)<br>Size: M18 E2EW-(Q)X10 18<br>14<br>Brass<br>Aluminum<br>12<br>10<br>8<br>Iron Copper<br>6<br>4 @d t=3mm<br>Stainless steel X<br>2 (SUS304)<br>0<br>0 10 20 30 40 50 60 70 80 90<br>Side length of sensing object: d (mm)<br>Size: M30 E2EW-(Q)X20 30<br>25<br>Brass Iron<br>20<br>Aluminum<br>15<br>Copper<br>10<br>@d<br>t=3mm<br>Stainless steel X<br>5 (SUS304)<br>0<br>0 10 20 30 40 50 60 70 80 90 100 110 120<br>Side length of sensing object: d (mm)<br>Distance X (mm)<br>Distance X (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> **12** **E2EW Series** ## **BASIC Model** ## **Single distance model/ Spatter-resistant Single distance model Shielded** **Size: M12 E2EW-(Q)X2** **12** **==> picture [204 x 277] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>@d t=3mm Iron<br>X<br>2<br>1 Brass Stainless steel<br>(SUS304)<br>Aluminum Copper<br>0<br>0 10 20 30 40 50 60 70 80 90<br>Side length of sensing object: d (mm)<br>Size: M18 E2EW-(Q)X5 18<br>8<br>@d<br>7 X t=3mm<br>Iron<br>6<br>5<br>4<br>Stainless steel<br>3 (SUS304)<br>2<br>Brass<br>1 Aluminum<br>0<br>0 10 20 30 40 50 60 70 80 90<br>Side length of sensing object: d (mm)<br>Distance X (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> ## **Size: M18 E2EW-(Q)X5** **18** ## **Size: M30 E2EW-(Q)X10** **30** **==> picture [202 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> 14<br>@d<br>12 X t=3mm Iron<br>10<br>Stainless steel<br>8 (SUS304)<br>6<br>4 Brass<br>2 Aluminum<br>0<br>0 10 20 30 40 50 60 70 80 90<br>Side length of sensing object: d (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> **13** **E2EW Series** ## **Influence of Sensing Object Thickness and Material** ## **PREMIUM Model** **==> picture [470 x 527] intentionally omitted <==** **----- Start of picture text -----**<br> Quadruple distance model/ Triple distance model/<br>Spatter-resistant Quadruple distance model Spatter-resistant Triple distance model<br>Shielded Shielded<br>Size: M12 E2EW-(Q)X7 12 Size: M12 E2EW-(Q)X6 12<br>10 10<br>Aluminum<br>Brass Aluminum Brass<br>8 8<br>6 Iron 6<br>Copper<br>Copper Iron<br>4 t 4 t<br>X X<br>Stainless steel Stainless steel<br>(SUS304) (SUS304)<br>2 2<br>Sensing object size: Sensing object size:<br>21 × 21 mm 18 × 18 mm<br>0<br>0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br>Thickness of sensing object: t (mm) Thickness of sensing object: t (mm)<br>Size: M18 E2EW-(Q)X12 18 Size: M18 E2EW-(Q)X10 18<br>16<br>16<br>14<br>14<br>Brass Brass<br>12<br>12<br>10<br>10<br>Iron<br>8 Aluminum Copper 8 Iron [Aluminum] Copper<br>6 t 6 t X<br>Stainless steel X 4 Stainless steel<br>4 (SUS304) (SUS304)<br>2<br>2 Sensing object size: Sensing object size:<br>36 × 36 mm 30 × 30 mm<br>0<br>0 0 5 10 15 20<br>0 5 10 15 20<br>Thickness of sensing object: t (mm)<br>Thickness of sensing object: t (mm)<br>Size: M30 E2EW-(Q)X22 30 Size: M30 E2EW-(Q)X20 30<br>30 30<br>25 Brass 25<br>Brass<br>20 20<br>15 Iron Aluminum Copper 15<br>t Iron Aluminum Copper<br>10 Stainless steel X 10 t X<br>(SUS304) Stainless steel<br>(SUS304)<br>5 Sensing object size: 5<br>66 × 66 mm Sensing object size:<br>60 × 60 mm<br>0 0 5 10 15 20 0 0 5 10 15<br>Thickness of sensing object: t (mm) Thickness of sensing object: t (mm)<br>Distance X (mm) Distance X (mm)<br>Distance X (mm) Distance X (mm<br>Distance X (mm) Distance X (mm)<br>**----- End of picture text -----**<br> ## **Quadruple distance model/ Spatter-resistant Quadruple distance model Shielded** **==> picture [209 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> 10<br>Aluminum Brass<br>8<br>6<br>Copper Iron<br>4 t<br>X<br>Stainless steel<br>(SUS304)<br>2<br>Sensing object size:<br>18 × 18 mm<br>0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br>Thickness of sensing object: t (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> **==> picture [209 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 30<br>25<br>Brass<br>20<br>15<br>Iron Aluminum Copper<br>t<br>10 X<br>Stainless steel<br>(SUS304)<br>5<br>Sensing object size:<br>60 × 60 mm<br>0<br>0 5 10 15 20<br>Thickness of sensing object: t (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> **14** **E2EW Series** ## **BASIC Model** ## **Single distance model/ Spatter-resistant Single distance model Shielded** **Size: M12 E2EW-(Q)X2** **12** **==> picture [207 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>Iron<br>t<br>X<br>2<br>Stainless steel (SUS304) Sensing object size: 12 × 12 mm<br>1<br>Brass<br>Aluminum Copper<br>0<br>0 5 10 15 20<br>Thickness of sensing object: t (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> ## **Size: M18 E2EW-(Q)X5** **18** **==> picture [209 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 8<br>7<br>Iron<br>6<br>5 t<br>X<br>4 Stainless steel<br>(SUS304)<br>3 Sensing object size: 18 × 18 mm<br>2<br>1 Brass Aluminum<br>0<br>0 5 10 15 20<br>Thickness of sensing object: t (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> ## **Size: M30 E2EW-(Q)X10** **30** **==> picture [209 x 133] intentionally omitted <==** **----- Start of picture text -----**<br> 14<br>12 Iron<br>t<br>10 X<br>Stainless steel<br>8 (SUS304)<br>Sensing object size: 30 × 30 mm<br>6<br>4<br>2 Brass Aluminum<br>0<br>0 5 10 15 20<br>Thickness of sensing object: t (mm)<br>Distance X (mm)<br>**----- End of picture text -----**<br> **15** **E2EW Series** ## **Monitor Output vs. Sensing Distance** ## **PREMIUM Model** ## **Quadruple distance model/ Spatter-resistant Quadruple distance model Shielded** **Size: M12 E2EW-(Q)X7** **12** **==> picture [218 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> 300<br>@d=21 mm<br>250 t=3 mm X<br>200<br>Iron Aluminum<br>150<br>100<br>Stainless steel<br>(SUS304)<br>50<br>0<br>0 2 4 6 8 10<br>Distance X (mm)<br>Detection level<br>**----- End of picture text -----**<br> **Size: M18 E2EW-(Q)X12** **18** **==> picture [216 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> 300<br>@d=36 mm<br>t=3 mm<br>250 X<br>Aluminum<br>200<br>Iron<br>150<br>100<br>Stainless steel<br>(SUS304)<br>50<br>0<br>0 5 10 15<br>Distance X (mm)<br>Detection level<br>**----- End of picture text -----**<br> **Size: M30 E2EW-(Q)X22** **30** **==> picture [217 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> 300<br>@d=66 mm<br>250 t=3 mm X<br>Aluminum<br>200<br>Iron<br>150<br>100<br>Stainless steel<br>(SUS304)<br>50<br>0<br>0 5 10 15 20 25 30<br>Distance X (mm)<br>Detection level<br>**----- End of picture text -----**<br> ## **Triple distance model/ Spatter-resistant Triple distance model Shielded** **==> picture [114 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Size: M12 E2EW-(Q)X6 12<br>**----- End of picture text -----**<br> **==> picture [218 x 470] intentionally omitted <==** **----- Start of picture text -----**<br> 300<br>@d=18 mm<br>250 t=3 mm X<br>Aluminum<br>200<br>Iron<br>150<br>100<br>50 Stainless steel<br>(SUS304)<br>0<br>0 2 4 6 8 10<br>Distance X (mm)<br>Size: M18 E2EW-(Q)X10 18<br>300<br>@d=30 mm<br>t=3 mm<br>250 X<br>Aluminum<br>200<br>Iron<br>150<br>100<br>50 Stainless steel<br>(SUS304)<br>0<br>0 5 10 15<br>Distance X (mm)<br>Size: M30 E2EW-(Q)X20 30<br>300<br>@d=60 mm<br>t=3 mm<br>250 X<br>200 Aluminum<br>Iron<br>150<br>100<br>Stainless steel<br>50 (SUS304)<br>0<br>0 5 10 15 20 25 30<br>Distance X (mm)<br>Detection level<br>Detection level<br>Detection level<br>**----- End of picture text -----**<br> **16** **E2EW Series** ## **I/O Circuit Diagrams/Timing charts** ## **DC 3-wire** ## **PNP output** ## **PREMIUM Model** |**Operation**<br>**mode**|**Model**||||**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| ||||||**Standard I/O mode (SIO mode)**<br>**When using as a general**|||||||||**IO-Link Communication mode (COM mode)**<br>**When using the Sensor connected to**<br>**IO-Link Master Unit**|||||||||||| |NO|E2EW-(Q)XB1|Pro<br>se<br>m<br>ci|||||||||OUT<br>0V<br>+V<br>DC10 to 30V<br>Brown (1)<br>Black (4)<br>Blue (3)<br>Load|||Proximity<br>sensor<br>main<br>circuit||||||Black (4)<br>Blue (3)<br>Brown (1)<br>IO-Link master<br>+V<br>C/Q<br>0V<br>+V (1)<br>0V (3)<br>C/Q (4)|||||| ||||Pro<br>se<br>m<br>ci||||||||||||Proximity<br>sensor<br>main<br>circuit|||||||||Black (4)<br>Blue (3)<br>Brown (1)<br>+V<br>C/Q<br>0V|+V (1)<br>0V (3)<br>C/Q (4)| ||||||ximity<br>nsor<br>ain<br>rcuit||||||||||||||imity<br>sor<br>in<br>uit||||||| ||||||||||||||||||||||||||| ||||||||||||||||||||||||||| ||||||||||||||||||||||||||| ||||||||||||||||||||||||||| ||||||||||||||||||||||||||| |NC|E2EW-(Q)XB2|P|||||||||OUT<br>0V<br>+V<br>Brown (1)<br>Black (2)<br>Blue (3)<br>Load<br>DC10 to 30V|||||||||---|||||| |||||P|roximity<br>sensor<br>main<br>circuit||||||||||||||||||||| |||||||ximity<br>nsor<br>ain<br>cuit|||||||||||||||||||| ||||||||||||Blue (3)<br>L||||||||||||||| ||||||||||||||||||||||||||| ||||||||||||||||||||||||||| |NO+NC|E2EW-(Q)XB3|Proximity<br>sensor<br>main<br>circuit|||||||||V<br>Brown (1)<br>DC10 to 30V|||||||||0V<br>C/Q (4)<br>+V (1)<br>0V (3)<br>DI (2)<br>C/Q<br>DO<br>0V<br>+V<br>Brown (1)<br>Black (4)<br>White (2)<br>Blue (3)<br>IO-Link master|||||| ||||Proximity<br>sensor<br>main<br>circuit||||||||||||||||||||||| |||||||mity|||||+||||||||||||C/Q<br>DO<br>0V<br>Brown (1)<br>Black (4)<br>White (2)||| ||||||||||||OUT1<br>Black (4)||||Prox|||imity|||||||| |||||se<br>m<br>ci|ns<br>ai<br>rcu|or<br>n<br>it|||||OUT2<br>Lo<br>Ld<br>White (2)||ad|||se<br>m<br>cir||nsor<br>ain<br>cuit|||||||| ||||||||||||||||||||||||||| ||||||||||||0V<br>oa<br>Blue (3)|a|||||||||||||| ||||||||||||||||||||||||||| ||||||||||||||||||||||||||| In the IO-Link mode, the cord between the IO-Link master and sensor must have a length of 20 m or less. ## **Connector Pin Arrangement** **M12 Connector M12 Smartclick Connector** 1 2 4 3 **17** **E2EW Series** ## **PNP output** |||||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Output mode|Operation<br>mode 1|||||||||||||||| |||||||nce||||||||||| |||||||||||||||||| ||||||dista|||||||||||| ||||(%)<br>1|||||||||||||| |Standard<br>I/O mode<br>(SIO mode) 2|NO|||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| ||NC|||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| ||NO+NC|||||||ON<br>OFF<br>ON<br>OFF<br>ON<br>OFF<br>ON<br>OFF<br>Comunication indicator (green) : Always OFF<br>Operation indicator (orange)<br>Control output 1 3<br>Control output 2 3|**ON delay**|||||||| ||||||||||1<br>0<br>1<br>0<br>NO<br>NC<br>ON<br>OFF<br>ON<br>OFF<br>Present<br>Not<br>present<br>Sensing<br>object|~~T~~<br>|||NO<br>ON<br><br>1<br><br>Presen<br>Not<br>presen<br>Sensing<br>object|||| |||||||||||||||||| ||||||||||||T||NC<br>OFF<br>ON<br>OFF<br>0<br>1<br>||~~T~~|| |||||||||||||||||| ||||||||||**One shot**||||**ONOFF**|||| ||||||||||1<br>0<br>1<br>0<br>NO<br>NC<br>ON<br>OFF<br>ON<br>OFF<br>Presen<br>Not<br>presen<br>Sensing<br>object|T<br><br><br>t<br>t|||1<br><br>NO<br>ON<br><br>Presen<br>Not<br>present<br>Sensing<br>object|||| |IO-Link<br>Communication<br>mode<br>(COM mode)|NO|||||||||||||||| ||||||||||||||||T|| ||||||||||||~~T~~||0<br>1<br>0<br>NC<br>OFF<br>ON<br>OFF||~~T~~|~~T~~| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| ||||||5|||||||||||| |||||||||||||||||| ||||||||4|||||||||| |||||||||||||||||| ||NC|||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| ||||||5|||||||||||| |||||||||||||||||| ||||||||4|||||||||| |||||||||||||||||| ||NO+NC|||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| ||||||5|||||||||||| |||||||||||||||||| ||||||||4|||||||||| |||||||||||||||||| Please contact your OMRON sales representative regarding assignment of data. 1. For models with IO-Link, the operation mode can be changed by the IO-Link communications. 2. If using a model with IO-Link as a general sensor or using a model without IO-Link, it operates in the standard I/O mode (SIO mode). **18** **E2EW Series** ## **DC 3-wire** |**DC 3-wire**|**DC 3-wire**||||||| |---|---|---|---|---|---|---|---| |**PNP output**||<br>**BASIC Model**|||||| ||||||||| |**Operation**<br>**mode**||**Model**||**Timing chart**|||**Output circuit**| |NO|E2EW-(Q)XB1|||Sensing<br>object<br>(%)<br>100<br>0<br>Nonsensing<br>area<br>Rated Sensing distance<br>Stable<br>sensing area<br>ProximitySensor<br>Operation indicator<br>(orange)<br>ON<br>OFF<br>ON<br>OFF<br>Control output||OUT<br>0V<br>Proximity<br>sensor<br>main<br>circuit<br>Brown (1)<br>DC10 to 30V<br>+V<br>Load<br>Blue (3)<br>Black (4)|| |NC|E2EW-(Q)XB2||Sensing<br>object<br>(%)<br>100<br>0<br>Nonsensing<br>area<br>Rated Sensing distance<br>Stable<br>sensing area<br>ProximitySensor<br>ON<br>OFF<br>Control output<br>ON<br>OFF<br>Operation indicator<br>(orange)|Nonsensing<br>area||OUT<br>0V<br>Brown (1)<br>DC10 to 30V<br>+V<br>Load<br>Blue (3)<br>Black (2)<br>Proximity<br>sensor<br>main<br>circuit|| ||||||ing distance||| |NO+NC|E2EW-(Q)XB3|||Sensing<br>object<br>(%)<br>100<br>0<br>Nonsensing<br>area<br>Rated Sensing distance<br>Stable<br>sensing area<br>ProximitySensor<br>ON<br>OFF<br>ON<br>OFF<br>Control output 1<br>Control output 2<br>ON<br>OFF<br>Operation indicator<br>(orange)||OUT1<br>OUT2<br>0V<br>Load<br>Load<br>Brown (1)<br>Black (4)<br>DC10 to 30V<br>+V<br>Blue (3)<br>Proximity<br>sensor<br>main<br>circuit<br>White (2)|| |||||Sensing<br>object<br>Rated Sen|sing distance||| |||||(%)<br>1<br>|||| ||||||||| ||||||||| ||||||||| ||||||||| ||||||||| ||||||||| ## **Connector Pin Arrangement** **M12 Connector M12 Smartclick Connector** 1 2 4 3 **19** **E2EW Series** ## **DC 3-wire** |**DC 3-wire**|**DC 3-wire**|||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**NPN OUTPUT**||<br>**PREMIUM Model**||||||||||||| |||||||||||||||| |**Operation**<br>**mode**||**Model**||**Timing chart**|||||**Output circuit**|||||| |NO|E2EW-(Q)XC1||100<br>0<br>Nonsensing<br>area<br>Stable<br>sensing area<br>Sensing<br>object<br>Rated Sensing distance<br>ProximitySensor<br>(%)<br>ON<br>OFF<br>ON<br>OFF<br>Operation indicator<br>(orange)<br>Control output|||||||||||| |||||||||||||||| |||||||||Proxi<br>sen<br>ma<br>circ||||||| |||||||||||||||| |||||||||||||||| |NC|E2EW-(Q)XC2||100<br>0<br>Nonsensing<br>area<br>Stable<br>sensing area<br>Sensing<br>object<br>(%)<br>Rated Sensing distance<br>ProximitySensor<br>Operation indicator<br>(orange)<br>Control output<br>ON<br>OFF<br>ON<br>OFF||||||OUT<br>0V<br>roximity<br>sensor<br>main<br>circuit<br>Brown (1)<br>Black (2)<br>Blue (3)<br>+V<br>DC10 to 30V<br>Load|||||| |||||||||P|roximity<br>sensor<br>main<br>circuit|||||| |||||||||||||||| |NO+NC|E2EW-(Q)XC3|||100<br>0<br>ON<br>OFF<br>ON<br>OFF<br>ON<br>OFF<br>Nonsensing<br>area<br>Stable<br>sensing area<br>Sensing<br>object<br>Rated Sensing distance<br>ProximitySensor<br>Operation indicator<br>(orange)<br>Control output 1<br>Control output 2<br>(%)||OUT1<br>OUT2<br>0V<br>DC10 to 30V<br>+V<br>Brown (1)<br>Black (4)<br>Blue (3)<br>White (2)<br>Proximity<br>sensor<br>main<br>circuit<br>Load<br>Load||||||||| |||||Sensing<br>object<br>Rated Sens|ing distance|||||||||| ||||||||Proximity<br>sensor<br>main<br>circuit|||||||| ||||||||||mity<br>sor<br>in<br>uit||||Black (4)<br>Lo|| |||||||||||||||L<br>ad| |||||1<br>(%)||||||||||| |||||||||||||||| |||||||||||||||| |||||||||||||||| |||||||||||||||| |||||||||||||||| |||||||||||||||| ## **Connector Pin Arrangement** **M12 Connector M12 Smartclick Connector** 1 2 4 3 **20** **E2EW Series** ## **DC 3-wire** ## **NPN OUTPUT BASIC Model** |**Operation**<br>**mode**|**Model**||**Timing chart**||||||**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**|**Output circuit**| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |NO|E2EW-(Q)XC1|Sensing<br>object<br>(%)<br>100<br>0<br>Nonsensing<br>area<br>Rated Sensing distance<br>Stable<br>sensing area<br>ProximitySensor<br>ON<br>OFF<br>ON<br>OFF<br>Operation indicator<br>(orange)<br>Control output||||||||||||||||| ||||||||Proximity<br>sensor<br>main<br>circuit|||||||||||| |||||||||||||||||||| |NC|E2EW-(Q)XC2|Operation indicator<br>(orange)<br>Control output<br>ON<br>OFF<br>ON<br>OFF<br>Sensing<br>object<br>(%)<br>100<br>0<br>Nonsensing<br>area<br>Rated Sensing distance<br>Stable<br>sensing area<br>ProximitySensor||||||||||||||||| ||||||||Proximity<br>sensor<br>main<br>circuit|||||||||||| |||||||||||||||||||| |NO+NC|E2EW-(Q)XC3|Sensing<br>object<br>(%)<br>100<br>0<br>Nonsensing<br>area<br>Rated Sensing distance<br>Stable<br>sensing area<br>ProximitySensor<br>ON<br>OFF<br>ON<br>OFF<br>ON<br>OFF<br>Operation indicator<br>(orange)<br>Control output 1<br>Control output 2||OUT1<br>0V<br>OUT2<br>Brown (1)<br>Black (4)<br>Blue (3)<br>White (2)<br>Load<br>Load<br>+V<br>DC10 to 30V<br>Proximity<br>sensor<br>main<br>circuit||||||||||||||| ||||||Proximity<br>sensor<br>main<br>circuit|||||||||||||| ||||||||||||||Black (4)<br>Lo|||||| |||||||||||||||Lo|ad||Lo|ad| |||||||Prox<br>se<br>m<br>cir||imity<br>nsor<br>ain<br>cuit||||||||||| |||||||||||||||||||| ## **Connector Pin Arrangement** **M12 Connector M12 Smartclick Connector** 1 2 4 3 **21** **E2EW Series** ## **Connections for Sensor I/O Connectors** ## **DC 3-Wire** ||**Proximity Sensor**|**Proximity Sensor**|**Proximity Sensor**|||**Sensor I/O Connectors**|**Sensor I/O Connectors**| |---|---|---|---|---|---|---|---| |**Types**|**Output**|**Operation**<br>**mode**|**Model**|**Model**|||**Connections1**| |DC 3-Wire<br>(M12 Connector)|PNP|NO|E2EW-(Q)XB1- M1TJ/M1|XS2F-<br>M124M<br>XS2W-D42-81-F|E2EW Serie<br>Main<br>circuit|**1**<br>**2**<br>**3**<br>**4**<br>**1**<br>**2**<br>**3**<br>**4**<br>XS<br>s|Brown (+)<br>White (not connected)<br>Blue (–)<br>Black (Output)<br>2| |||NC|E2EW-(Q)XB2-M1TJ/M1||E2EW Serie<br>Main<br>circuit|**1**<br>**2**<br>**3**<br>**4**<br>**1**<br>**2**<br>**3**<br>**4**<br>XS<br>s|Brown (+)<br>White (Output)<br>Blue (-)<br>Black (not connected)<br>2<br>2| |||NO+NC|E2EW-(Q)XB3-M1TJ/M1||E2EW Serie<br>Main<br>circuit|**1**<br>**2**<br>**3**<br>**4**<br>**1**<br>**2**<br>**3**<br>**4**<br>XS<br>s|Brown (+)<br>White (Output 2)<br>Blue (-)<br>Black (Output 1)<br>2| ||NPN|NO|E2EW-(Q)XC1-M1TJ/M1||E2EW Serie<br>Main<br>circuit|**1**<br>**2**<br>**3**<br>**4**<br>**1**<br>**2**<br>**3**<br>**4**<br>XS<br>s|Brown (+)<br>White (not connected)<br>Blue (-)<br>Black (Output)<br>2| |||NC|E2EW-(Q)XC2-M1TJ/M1||E2EW Serie<br>Main<br>circuit|**1**<br>**2**<br>**3**<br>**4**<br><br><br><br><br>XS<br>s|**1**<br>**2**<br>**3**<br>**4**<br>Brown (+)<br>White (Output)<br>Blue (-)<br>Black (not connected)<br>2<br>2| |||NO+NC|E2EW-(Q)XC3-M1TJ/M1||E2EW Serie<br>Main<br>circuit|**1**<br>**2**<br>**3**<br>**4**<br>**1**<br>**2**<br>**3**<br>**4**<br>XS<br>s|Brown (+)<br>White (Output 2)<br>Blue (-)<br>Black (Output 1)<br>2| 1. If the XS2W Series Connector which has a socket and plug on the cable ends is connected to the Sensor, this part will be a plug. 2. Different from Proximity Sensor wire colors. **22** **E2EW Series** ## **Safety Precautions** ## **Be sure to read the precautions for all models in the website at: http://www.automation.omron.com/. Warning Indications** ## **Precautions for Correct Use** ## **Warning level** Do not use the product in any atmosphere or environment that exceeds the ratings. Indicates a potentially hazardous situation **WARNING** which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. ## **Operating Environment** **1.** Do not install the Sensor in the following locations. - (1) Outdoor locations directly subject to sunlight, rain, snow, waterdroplets, or oil. **Precautions** Supplementary comments on what to do or **for Safe Use** avoid doing, to use the product safely. - (2) Locations subject to atmospheres with chemical vapors, inparticular solvents and acids. - (3) Locations subject to corrosive gases. **Precautions** Supplementary comments on what to do or avoid doing, to prevent failure to operate, **for Correct** malfunction or undesirable effect on product **Use** performance. **2.** The Sensor may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a high-frequency electric field. Please refer to the Precautions for Correct Use on the OMRON website (www.ia.omron.com) for typical measures. ## **Meaning of Product Safety Symbols** **3.** Laying the Proximity Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in incorrect operation and damage due to induction. Wire the Sensor using a separate conduit or independent conduit. ## **General prohibition** Indicates the instructions of unspecified prohibited action. **4.** Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. ## **Caution, explosion** **5.** When turning on the power by influence of temperature environment, an outputmis-pulse sometimes occurs. After the sensor has passed for 300 msec after turning on, please use in the stable state. Indicates the possibility of explosion under specific conditions. **6.** The sensor is adjusted with a high degree of accuracy, so do not use in the environment with sudden temperature change. ## **WARNING** **7.** Operation check is performed using an OMRON's IO-Link master. If using an IO-Link master from another company, perform the operation check in advance. **This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes.** **8.** When connecting non IO-Link compliant models to the IO-Link master, use the SIO mode. **9.** In the IO-Link mode, the cord between the IO-Link master and sensor must have a length of 20 m or less. **Otherwise, explosion may result. Never use the product with an AC power supply.** **10.** The Sensor cannot be used embedded in where pressure is constantly applied to the sensing surface, such as hydraulic cylinders and hydraulic valves. ## **Precautions for Safe Use** The following precautions must be observed to ensure safe operation. **1.** Do not use the product in environments subject to flammable or explosive gases. **2.** Do not attempt to disassemble, repair, or modify the product. **3.** Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in explosion or fire. **4.** Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or fire. **5.** If the power supply is connected directly without a load, the internal elements may explode or burn. **6.** Dispose of the product according to applicable regulations (laws). **23** **E2EW Series** ## **Design** ## **Influence of Surrounding Metal** When mounting the Proximity Sensor, ensure that the minimum distances given in the following table are maintained. If you use a nut, only use the provided nut. And ensure that the minimum distances between the sensing surface and nut is bigger than the "L" given in the following table. |When mounting the Proximity Sensor, ensure that the minimum<br>distances given in the following table are maintained.<br>If you use a nut, only use the provided nut. And ensure that the<br>minimum distances between the sensing surface and nut is bigger<br>than the "L" given in the following table.|When mounting the Proximity Sensor, ensure that the minimum<br>distances given in the following table are maintained.<br>If you use a nut, only use the provided nut. And ensure that the<br>minimum distances between the sensing surface and nut is bigger<br>than the "L" given in the following table.|When mounting the Proximity Sensor, ensure that the minimum<br>distances given in the following table are maintained.<br>If you use a nut, only use the provided nut. And ensure that the<br>minimum distances between the sensing surface and nut is bigger<br>than the "L" given in the following table.| |---|---|---| |Other non-ferrous metals affect sensor's performance in the same||| |way as aluminum. Perform the operation check in advance.||| |**(Unit: mm)**<br>**Mounting panel material: Iron**<br>**Mounting panel material: Aluminum**<br>**Models**<br>**Model**<br>**L**<br>**d**<br>**D**<br>**m**<br>**Quadruple**<br>**distance model**<br>**E2EW-(Q)X7****12**<br>4<br>30<br>4<br>28<br>**E2EW-(Q)X12****18**<br>6<br>54<br>6<br>36<br>**E2EW-(Q)X22****30**<br>8<br>90<br>8<br>66<br>**Triple distance**<br>**model**<br>**E2EW-(Q)X6****12**<br>4<br>30<br>4<br>24<br>**E2EW-(Q)X10****18**<br>2<br>54<br>2<br>30<br>**E2EW-(Q)X20****30**<br>0<br>30<br>0<br>60<br>**Single distance**<br>**model**<br>**E2EW-(Q)X2****12**<br>0<br>12<br>0<br>8<br>**E2EW-(Q)X5****18**<br>0<br>18<br>0<br>20<br>**E2EW-(Q)X10****30**<br>0<br>30<br>0<br>40<br>**Models**<br>**Model**<br>**L**<br>**d**<br>**D**<br>**m**<br>**Quadruple**<br>**distance model**<br>**E2EW-(Q)X7****12**<br>12<br>70<br>12<br>28<br>**E2EW-(Q)X12****18**<br>12<br>80<br>12<br>36<br>**E2EW-(Q)X22****30**<br>16<br>120<br>16<br>66<br>**Triple distance**<br>**model**<br>**E2EW-(Q)X6****12**<br>12<br>70<br>12<br>24<br>**E2EW-(Q)X10****18**<br>12<br>80<br>12<br>30<br>**E2EW-(Q)X20****30**<br>16<br>120<br>16<br>60<br>**_*_1**<br>**d**dia.<br>|<br>a<br>mi<br>+B~~.~~<br>~~=~~<br>ee<br>ee ee ee<br>PS———a<br>~~==~~<br>es<br>|<br>ee eee ee<br>PF<br>CE<br>———a<br>———a||**(Unit: mm)**<br>**n**<br>36<br>54<br>90<br>36<br>54<br>90<br>40<br>60<br>100<br>**n**<br>70<br>80<br>120<br>70<br>80<br>120| |**Single distance**<br>**model**<br>**E2EW-(Q)X2****12**<br>12<br>70<br>12<br>8<br>**E2EW-(Q)X5****18**<br>12<br>80<br>12<br>20<br>**E2EW-(Q)X10****30**<br>16<br>120<br>16<br>40<br>~~—~~—||70<br>80<br>120| |1.<br>If you use the model E2EW-(Q)X2230, or E2EW-(Q)X2030,||| |the panel thickness (t) is 3 mm or less.||| When the Proximity Sensor is mounted in metal, ensure that the minimum distances given in the following table are maintained. |Ls<br>eF,<br>38|| |---|---| |**d**dia.<br>Ls<br>eF,<br>38<br>[~~2 ~~el|| |**(Unit: mm)**|| |**Embedded material: Iron**<br>*2.If the thickness of the mounting bracket (t) is less than 10 mm, be<br>**Models**<br>**Model**<br>**l**<br>**d**<br>**D**<br>**m**<br>**Quadruple**<br>**distance model**<br>**E2EW-(Q)X7****12**<br>4<br>30<br>4<br>28<br>**E2EW-(Q)X12****18**<br>6<br>54<br>6<br>36<br>**E2EW-(Q)X22****30**<br>8<br>90<br>8<br>66<br>**Triple distance**<br>**model**<br>**E2EW-(Q)X6****12**<br>02<br>122<br>02<br>24<br>**E2EW-(Q)X10****18**<br>0<br>18<br>0<br>30<br>**E2EW-(Q)X20****30**<br>0<br>30<br>0<br>60<br>**Single distance**<br>**model**<br>**E2EW-(Q)X2****12**<br>0<br>12<br>0<br>8<br>**E2EW-(Q)X5****18**<br>0<br>18<br>0<br>20<br>**E2EW-(Q)X10****30**<br>0<br>30<br>0<br>40<br>To<br>LLL<br>~~——r~~<br>PS<br>ee<br>~~———~~aa<br>~~=~~<br>Eeee|If the thickness of the mounting bracket (t) is less than 10 mm, be<br>**n**<br>36<br>54<br>90<br>36<br>54<br>90<br>40<br>60<br>100| *2. If the thickness of the mounting bracket (t) is less than 10 mm, be sure to install the Sensor so that l 2, d (dia.) 30, and D 2. ## **Embedded material: Aluminum** |**Models**|**Model**<br>~~e~~|**l**<br>~~ee~~|**d**<br>~~e~~|**D**<br>~~e~~|**m**<br>~~e~~|**n**| |---|---|---|---|---|---|---| |**Quadruple**<br>**distance model**|**E2EW-(Q)X7****12**<br>~~e~~|12<br>~~ee~~|70<br>~~e~~|12<br>~~e~~|28<br>~~e~~|70| ||**E2EW-(Q)X12****18**|12|80|12|36|80| ||**E2EW-(Q)X22****30**|16|120|16|66|120| |**Triple distance**<br>**model**<br>SP|**E2EW-(Q)X6****12**<br>~~P~~|12<br>~~P~~E|70<br>E|12<br>E|24<br>E|70| ||**E2EW-(Q)X10****18**<br>~~P~~<br>~~e~~|12<br>~~P~~E<br>~~e~~e<br>ee|80<br>E<br>e<br>ee|12<br>E<br>e<br>ee|30<br>E<br>e|80| ||**E2EW-(Q)X20****30**<br>~~P~~<br>~~e~~<br>SP<br>re|16<br>~~P~~E<br>~~e~~e<br>ee<br>EE|120<br>E<br>e<br>ee<br>EE|16<br>E<br>e<br>ee<br>EE|60<br>E<br>e<br>EE|120| |**Single distance**<br>**model**<br>SP|**E2EW-(Q)X2****12**<br>~~e~~<br>SP<br>re|12<br>~~e~~e<br>ee<br>EE|70<br>e<br>ee<br>EE|12<br>e<br>ee<br>EE|8<br>e<br>EE|70| ||**E2EW-(Q)X5****18**<br>SP<br>re<br>————|12<br>ee <br>EE<br>————|80<br> ee <br>EE<br>————|12<br> ee<br>EE<br>————|20<br>EE<br>————|80| ||**E2EW-(Q)X10****30**<br>————|16<br>————|120<br>————|16<br>————|40<br>————|120| **24** **E2EW Series** ## **Mutual Interference** When installing two or more Proximity Sensors face-to-face or sidebyside, ensure that the minimum distances given in the following table are maintained. **==> picture [156 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> B<br>A<br>A<br>**----- End of picture text -----**<br> ## **(Unit: mm)** |**Models**|**Model**|**Item**|**Item**| |---|---|---|---| |||**A**|**B**| |**Quadruple**<br>**distance model**|E2EW-(Q)X712|45|40| ||E2EW-(Q)X1218|80|60| ||E2EW-(Q)X2230|135|110| |**Triple distance**<br>**model**|E2EW-(Q)X612|45|40| ||E2EW-(Q)X1018|80|60| ||E2EW-(Q)X2030|135|110| |**Single distance**<br>**model**|E2EW-(Q)X212|40|35| ||E2EW-(Q)X518|65|60| ||E2EW-(Q)X1030|110|100| ## **Chips from Cutting Aluminum** Normally, chips from cutting aluminum will not cause a detection signal to be output even if it adheres to or accumulates on the detection surface. In the following cases, however, a detection signal may be output. ## **Mounting** ## **Tightening Force** Do not tighten the nut with excessive force. A washer must be used with the nut. The tightening force must be the same or less than the figures in the following table. **==> picture [52 x 31] intentionally omitted <==** **==> picture [7 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Tr<br>**----- End of picture text -----**<br> ## **Quadruple distance model, Triple distance model** ## **(Unit: N·m)** |**Size**|**Torque**| |---|---| |M12|20 (15)| |M18|70 (35)| |M30|180 (60)| * Tighten the nut of the E2EW-Q to a torque in parentheses. ## **Single distance model** ## **(Unit: N·m)** |**Size**|**Torque**| |---|---| |M12|30 (15)| |M18|70 (35)| |M30|180 (60)| * Tighten the nut of the E2EW-Q to a torque in parentheses. **Note:** When mounting the Proximity Sensor, only use the provided nut. Do not use set screws. The Sensor may malfunction. Remove the cutting chips in these cases. |1. If d ≥ 2/3D at|the center of the detection|the center of the detection|||d||| |---|---|---|---|---|---|---|---| |surface where d is the cutting chip size and|||D is||||| |the detection surface size|||||||Cutting<br>chips| |||**(Unit: mm)**|||D||Detection| |**Model**|**Dimension**|**D**|||||surface| |**E2EW-(Q)X****12**||10|||||| |**E2EW-(Q)X****18**||16|||||| |**E2EW-(Q)X****30**||28|||||| ||||||||| 2.If the cutting chips are pressed down **==> picture [54 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> Pressed down<br>Cutting<br>chips<br>**----- End of picture text -----**<br> **==> picture [42 x 51] intentionally omitted <==** **25** **E2EW Series Dimensions** **(Unit: mm)** Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. ## **Sensors** ## ~~[Lo~~ **PREMIUM Model E2EW/E2EW-Q Series** **(Quadruple distance/Triple distance/Spatter-resistant Quadruple distance, Spatter-resistant Triple distance model)** ## **Pre-wired Model/** **M12 Connector Model** **Pre-wired Connector Model** |**Pre-wired Model/**<br>**Pre-wired Connector Model**<br>eS|**M12 Connector Model**<br>x| |---|---| |C<br>B<br>A<br>D<br>E<br>(Operation mode):<br>Output configuration (B1, C1): NO<br>(B2, C2): NC<br>Vinyl-insulated round cable with<br>3 conductors size: 6-dia.<br>(Conductor cross section: 0.3 mm2(AWG24),<br>Insulator diameter: 1.05 mm),<br>Standard length: 2 m<br>(Operation mode):<br>Output configuration (B3, C3): NO+NC<br>Vinyl-insulated round cable with<br>4 conductors size: 6-dia.<br>(Conductor cross section: 0.3 mm2(AWG24),<br>Insulator diameter: 1.05 mm),<br>Standard length: 2 m<br>Toothed washer<br>M12×P1<br>Pre-wired Model<br>Pre-wired Connector Model (M1TJ)<br>Two clamping nuts<br>F<br>G<br>* Models with IO-Link only.<br>Indicators<br>Standard I/O mode (SIO mode):<br>Operation indicator (orange/ON),<br>communication indicator (green/OFF)<br>IO-Link Communication mode<br>(COM mode):<br>Operation indicator (orange/ON),<br>comunication indicator<br>(green/Flashing (1sec cycle)*<br>(Operation mode):<br>Output configuration (B1, C1): NO<br>(B2, C2): NC<br>Vinyl-insulated round cable with<br>3 conductors size: 6-dia.<br>(Conductor cross section: 0.3 mm2(AWG24),<br>Insulator diameter: 1.05 mm),<br>Standard length:0.3 m<br>(Operation mode):<br>Output configuration (B3, C3): NO+NC<br>Vinyl-insulated round cable with<br>4 conductors size: 6-dia.<br>(Conductor cross section: 0.3 mm2(AWG24),<br>Insulator diameter: 1.05 mm),<br>Standard length: 0.3 m<br>**Models**<br>**Model**<br>**A**<br>**B**<br>**C**<br>**D**<br>**E**<br>**F**<br>**G**<br>Quadruple<br>distance<br>model<br>E2EW-(Q)X7<br>12(-M1TJ)<br>M12P1<br>41.5<br>30<br>4<br>10<br>21 dia.<br>17<br>E2EW-(Q)X12<br>18(-M1TJ)<br>M18P1<br>41.5<br>30<br>4<br>13<br>29 dia.<br>24<br>E2EW-(Q)X22<br>30(-M1TJ)<br>M30P1.5<br>41.5<br>30<br>5<br>13<br>42 dia.<br>36<br>Triple<br>distance<br>model<br>E2EW-(Q)X6<br>12(-M1TJ)<br>M12P1<br>41.5<br>30<br>4<br>10<br>21 dia.<br>17<br>E2EW-(Q)X10<br>18(-M1TJ)<br>M18P1<br>41.5<br>30<br>4<br>13<br>29 dia.<br>24<br>E2EW-(Q)X20<br>30(-M1TJ)<br>M30P1.5<br>41.5<br>30<br>5<br>13<br>42 dia.<br>36<br>~~==~~<br>.<br>~~__v~~<br>~~N~~<br>~~:~~<br>~<br>ee<br>~~|~~<br>tT<br>ft<br>a eee<br>ee ee<br>a<br>aeee|C<br>B<br>D<br>F<br>E<br>A<br>* Models with IO-Link only.<br>Indicators<br>Standard I/O mode (SIO mode):<br>Operation indicator (orange/ON),<br>communication indicator (green/OFF)<br>IO-Link Communication mode<br>(COM mode):<br>Operation indicator (orange/ON),<br>comunication indicator<br>(green/Flashing (1sec cycle)*<br>M12×P1<br>G<br>H<br>Toothed washer<br>Two clamping nuts<br>**Models**<br>**Model**<br>**A**<br>**B**<br>**C**<br>**D**<br>**E**<br>**F**<br>**G**<br>**H**<br>Quadruple<br>distance<br>model<br>E2EW-(Q)<br>X712-M1<br>M12P1<br>54.4<br>---<br>4<br>28<br>8<br>21 dia.<br>17<br>E2EW-(Q)<br>X1218-<br>M1<br>M18P1<br>54.4<br>32<br>4<br>28<br>11<br>29 dia.<br>24<br>E2EW-(Q)<br>X2230-<br>M1<br>M30P1.5<br>54.4<br>32<br>5<br>28<br>11<br>42 dia.<br>36<br>Triple<br>distance<br>model<br>E2EW-(Q)<br>X612-M1<br>M12P1<br>54.4<br>---<br>4<br>28<br>8<br>21 dia.<br>17<br>E2EW-(Q)<br>X1018-<br>M1<br>M18P1<br>54.4<br>32<br>4<br>28<br>11<br>29 dia.<br>24<br>E2EW-(Q)<br>X2030-<br>M1<br>M30P1.5<br>54.4<br>32<br>5<br>28<br>11<br>42 dia.<br>36<br>ee<br>a~~EA~~<br>FA<br>aee<br>FA| **Mounting Hole Dimensions Angle R of the Bending Wire** |F|**Dimensions**<br>**F (mm)**<br>M12<br>12.5 dia.<br>M18<br>18.5 dia.<br>M30<br>30.5 dia.<br>+0.5<br>0<br>+0.5<br>0<br>+0.5<br>0<br>~~—~~|||10 mm<br>R|**Dimensions**<br>M12<br>M18<br>M30|**R (mm)**<br>18| |---|---|---|---|---|---|---| **26** **E2EW Series** **Dimensions** **(Unit: mm)** Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. ## **Sensors** ## ~~Loo~~ **BASIC Model E2EW/E2EW-Q Series (Single distance model/Spatter-resistant Single distance model)** |**Pre-wired Model/**|**Pre-wired Model/**|**Pre-wired Model/**|**Pre-wired Model/**||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |**Pre-wired Connector Model**|||||||||||||||||| |||x<br>ay”||||||P<br>,|||||||||| |||||||B|||||||||||| ||||C<br>F||||||||||||||| ||||D<br>G|||~~E~~|||Operation indicator||||||||| ||||||||||(orange)||||||||| ||||||||||||||||||| ||A<br>Toothed washer<br>Two clamping nuts<br>Wyy ~~AN~~ BR||||||||||||||||| |||Pre-wired Model|||||||Pre-wired Connector Model (M1TJ)||||||||| |(Operation mode):<br>Output configuration (B1, C1): NO<br>(B2, C2): NC<br>~~.~~|||||Output configuration (B1, C1): NO<br>(B2, C2): NC|||Output configuration (B1, C1): NO<br>(B2, C2): NC|~~See~~|||||||M12×P1|| ||||Vinyl-insulated round cable with<br>3 conductors size: 6-dia.<br>(Conductor cross section:<br>0.3 mm2(AWG24),<br>Insulator diameter: 1.05 mm),||||||(Operation mode):<br>Output configuration (B1, C1): NO<br>(B2, C2): NC<br>Vinyl-insulated round cable with<br>3 conductors size: 6-dia.||||||||| ||||Standard length: 2 m||||||(Conductor cross section:||||||||| ||||||||||0.3 mm2 (AWG24),||||||||| ||||||||||Insulator diameter: 1.05 mm),||Insulator diameter: 1.05 mm),||||||| ||||||||||Standard length: 0.3 m||||||||| ||||(Operation mode):||||||||||||||| ||||Output configuration (B3, C3):|||Output configuration (B3, C3):|||(Operation mode):||(Operation mode):||||||| ||||NO+NC||||||Output configuration (B3, C3): NO+NC||||||||| ||||Vinyl-insulated round cable with||||||Vinyl-insulated round cable||||||||| ||||4 conductors size: 6-dia.||||||with 4 conductors size: 6-dia.||||||||| ||||(Conductor cross section:||||||(Conductor cross section:||||||||| ||||0.3 mm2(AWG24),||||||0.3 mm2(AWG24),||||||||| ||||Insulator diameter: 1.05 mm),||||||Insulator diameter: 1.05 mm),||Insulator diameter: 1.05 mm),||||||| ||||Standard length: 2 m||||||Standard length: 0.3 m||||||||| |**Models**<br>**Model**||||||||**A**|**B**<br>**C**||**D**||**E**|||**F**|**G**| ||||E2EW-(Q)X2<br>12(-M1TJ)|||M12P1<br>41.9<br>30.4|||||4||7||21 dia.|21 dia.|17| |Single<br>distance<br>model<br>E2EW-(Q)X5<br>18(-M1TJ)||||||M18P1<br>41.9<br>30.4|||||4||10||29 dia.|29 dia.|24| ||||E2EW-(Q)X10<br>30(-M1TJ)||M30P1.5<br>41.9<br>30.3||||||5||10||42 dia.|42 dia.|36| **Mounting Hole Dimensions** ## **Angle R of the Bending Wire** 10 mm **Dimensions F (mm) Dimensions R (mm)** M12 12.5 dia. +0.50 M12 M18 18.5 dia. +0.50 M18 18 F ~~=~~ M30 30.5 dia. +0.50 R ~~i~~ M30 **27** **OMRON AUTOMATION AMERICAS HEADQUARTERS •** Chicago, IL USA **•** 847.843.7900 **•** 800.556.6766 **•** automation.omron.com ## **OMRON CANADA, INC. • HEAD OFFICE** Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com ## **OMRON ELECTRONICS DE MEXICO • HEAD OFFICE** Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com ## **OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE** São Paulo, SP, Brasil • 55 11 5171-8920 • automation.omron.com ## **OMRON ARGENTINA • SALES OFFICE** Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483 mela@omron.com ## **OMRON ELECTRONICS DE MEXICO • SALES OFFICE** San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron. com ## **OTHER OMRON LATIN AMERICA SALES** +54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com ## **OMRON ELECTRONICS DE MEXICO • SALES OFFICE** Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com ## _Authorized Distributor:_ ## **Controllers & I/O** - Machine Automation Controllers (MAC) • Motion Controllers • Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O **Robotics** • Industrial Robots • Mobile Robots ## **Operator Interfaces** - Human Machine Interface (HMI) ## **Motion & Drives** - Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems • Frequency Inverters **Vision, Measurement & Identification** - Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems ## **Sensing** - Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors • Rotary Encoders • Ultrasonic Sensors ## **Safety** - Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems • Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices • Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays **Control Components** • Power Supplies • Timers • Counters • Programmable Relays • Digital Panel Meters • Monitoring Products **Switches & Relays** - Limit Switches • Pushbutton Switches • Electromechanical Relays • Solid State Relays ## **Software** - Programming & Configuration • Runtime D122DI-E3-02 Note: Specifications are subject to change. © 2021 Omron. All Rights Reserved. Printed in U.S.A. _Printed on recycled paper._
Updated at June 8, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →