Image not available
Illustrative purposes only
DX-KEY-OLED
OLED Remote Keypad, Power XL Series Motor Starters, Full Text Display, Multi Line Text
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: EATON MOELLER
- Product type: Controller Accessories
- Current Rating:-; Product Range:-; SVHC:No SVHC (17-Dec-2015)
- Product Range: -
- Current Rating: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 252.98 € |
| Current stock | 10+ |
| Lead time | 30 days |
## Adjustable Frequency Drives
## **PowerXL DC1**
## **PowerXL DG1**
## **Enclosed 18-Pulse Drive**
|**_OEM Drives_**|**_OEM Drives_**||**2**|
|---|---|---|---|
|**2.1**|**PowerXL DC1 Series Drives**|||
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-2**|**2**|
|**2.2**|**PowerXL DA1 Series Drives**||**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-11**|**2**|
|**2.3**|**M-Max Series Drives**<br>Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-20**|**2**|
|**_General Purpose Industrial Drives_**|||**2**|
|**2.4**|**PowerXL DG1 Series Drives**||**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-30**|**2**|
|**2.5**|**SVX9000 Drives**<br>Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-45**|**2**|
||SVX9000 Drives||**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>SVX9000 Enclosed Drives|**V6-T2-48**|**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-87**|**2**|
||SVX9000 VFD Pump Panels|||
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-111**|**2**|
|**_General Purpose HVAC Drives_**|||**2**|
|**2.6**|**H-Max Series Drives**||**2**|
||Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-131**||
||H-Max Drives||**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>H-Max IntelliPass and IntelliDisconnect Drives|**V6-T2-132**|**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-141**|**2**|
|**_Performance Drives_**|||**2**|
|**2.7**|**SPX9000 Drives**<br>Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-158**|**2**|
|**2.8**|**Low Harmonic Drives**||**2**|
||Enclosed Passive Filtered Drives||**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-200**||
||Enclosed 18-Pulse Drives||**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-233**|**2**|
|**2.9**|**LCX9000 Liquid Cooled Drives**|||
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-263**|**2**|
|**2.10**|**SPA9000/SPN9000/SPI9000 Common DC Bus Drives**||**2**|
||Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-280**|**2**|
Learn Drawings An Eaton Online Online a Green Solution
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-1**
Adjustable Frequency Drives
2.1
PowerXL DC1 Series Drives
## **PowerXL DC1 Series Drives**
## **Contents**
## _**Description Page**_
**2**
## **Product Description**
Eaton’s PowerXL™ DC1 variable frequency drives are the next generation of drives specifically engineered for today’s machinery applications.
The DC1 is compact with only 14 basic parameters, SmartWire-DT™ connectivity, and outstanding ease of mounting and installation. The DC1 is perfect for quick commissioning and is ideal for panel builders. This drive supports single-phase motor applications, and detachable terminal blocks make control wiring much easier.
Models rated at 480 volts, three-phase, 50/60 Hz are available in sizes ranging from 1 to 15 hp. Models rated at 240 volts, single- or threephase, 50/60 Hz are available in sizes ranging from 0.5 to 7.5 hp. Models rated at 115 volts, single-phase, 50/60 Hz are available in the 0.5 to 3 hp size range.
## **Features**
- Compact, space-saving design
- Rugged and reliable—175% for 2s, 50°C rated
- DIN rail and screw mountable (FS1 and FS2)
- Side-by-side installation
- Industry-leading efficiency delivers energy savings to the customer
- Optional integrated EMC filters make the unit suitable for commercial and industrial networks
|**_Description_**|**_Page_**|
|---|---|
|PowerXL DC1 Series Drives||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V6-T2-3**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-4**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-6**|
|Technical Data and Specifications . . . . . . . . . .|**V6-T2-7**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-9**|
## **Standards and Certifications**
- Brake chopper as standard in frames 2 and higher
## _**Product**_
- Temperature-controlled fan
- Complies with EN61800-3 (2004)
- RS-485/Modbus[®] and CANopen™ as standard
- PI controller as standard
## _**EMC (At Default Settings)**_
- SmartWire capability
- EMC Category C1, C2 and C3 at default settings (1m, 5m, 25m)
- Removable I/O terminal blocks
- Contactor style power wiring
## _**Safety**_[1]
- 61800-5-1
- Compatibility with singlephase motors
- EN 60529
- CE
- UL
- cUL
- UkrSepro
- c-Tick
- RoHS compliant
## _**Note**_
- 1 See unit nameplate for more detailed approvals.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-2**
Adjustable Frequency Drives
2.1
PowerXL DC1 Series Drives
## **Catalog Number Selection**
## **DC1 Series Adjustable Frequency AC Drives**
**==> picture [427 x 237] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC1 - 1 2 4D1 F N - A 20 N<br>Device Series Type<br>DC1 = Variable frequency drive, compact, Series 1 N = Standard basic device<br>( D = Drives, C = Compact, 1 = Series 1)<br>Degree of Protection<br>Connection in Power Section 20 = IP20/NEMA 0<br> = Single-phase mains connection/three-phase motor connection 66 = IP66/NEMA 4<br> = Three-phase mains connection/three-phase motor connection 6S = IP66 with disconnect/NEMA 4<br> = Single-phase mains connection/single-phase motor connection<br>Display Unit (Display)<br>Mains Voltage Category A = LED display<br>1 = 110V (110–115V ±10%)<br>2 = 230V (200–240V ±10%)<br>4 = 460V (380–480V ±10%) Brake Chopper<br>D = 110V input/230V output (voltage doubler)<br>N = No internal brake chopper<br>B = Brake chopper<br>Rated<br>Operational Current<br>EMC (Radio Interference Suppression Filter)<br>Examples—<br>2D2 = 2.2A N = No internal RFI filter<br>4D1 = 4.1A F = Internal RFI filter<br>024 = 24A<br>**----- End of picture text -----**<br>
**==> picture [234 x 225] intentionally omitted <==**
**----- Start of picture text -----**<br>
Device Series<br>DC1 = Variable frequency drive, compact, Series 1<br>( D = Drives, C = Compact, 1 = Series 1)<br>Connection in Power Section<br>1 = Single-phase mains connection/three-phase motor connection<br>3 = Three-phase mains connection/three-phase motor connection<br>S = Single-phase mains connection/single-phase motor connection<br>Mains Voltage Category<br>1 = 110V (110–115V ±10%)<br>2 = 230V (200–240V ±10%)<br>4 = 460V (380–480V ±10%)<br>D = 110V input/230V output (voltage doubler)<br>Rated<br>Operational Current<br>Examples—<br>2D2 = 2.2A<br>4D1 = 4.1A<br>024 = 24A<br>**----- End of picture text -----**<br>
**==> picture [196 x 215] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type<br>N = Standard basic device<br>Degree of Protection<br>20 = IP20/NEMA 0<br>66 = IP66/NEMA 4<br>6S = IP66 with disconnect/NEMA 4<br>Display Unit (Display)<br>A = LED display<br>Brake Chopper<br>N = No internal brake chopper<br>B = Brake chopper<br>EMC (Radio Interference Suppression Filter)<br>N = No internal RFI filter<br>F = Internal RFI filter<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-3**
Adjustable Frequency Drives
2.1
PowerXL DC1 Series Drives
**2 IP20** ~~=~~ **2**
## **Product Selection**
**DC1 Series IP20 Enclosure Drives**[1]
|**hp**2|**kW**|**Volts**|**100% Continuous**<br>**Current In (A)**|**Frame**<br>**Size**3|**Catalog Number**|
|---|---|---|---|---|---|
|0.5|0.37|115V single-phase in/|7|1|**DC1-S17D0NN-A20N**|
|0.75|0.55|115V single-phase out|10.5|2|**DC1-S1011NB-A20N**|
|0.5|0.37|200–240V single-phase in/|4.3|1|**DC1-S24D3NN-A20N**4|
|1|0.75|200–240V single-phase out|7|1|**DC1-S27D0NN-A20N**4|
|1.5<br>0.5<br>1|1.1<br>0.37<br>0.75|115V single-phase in/<br>230V three-phase out|10<br>2.3<br>4.3|2<br>1<br>1|**DC1-S2011NB-A20N**4<br>**DC1-1D2D3NN-A20N**4<br>**DC1-1D4D3NN-A20N**|
|1.5|1.1||5.8|2|**DC1-1D5D8NB-A20N**|
|0.5|0.37|200–240V single-phase in/|2.3|1|**DC1-122D3NN-A20N**4|
|1|0.75|230V three-phase out|4.3|1|**DC1-124D3NN-A20N**4|
|2|1.5||7|1|**DC1-127D0NN-A20N**4|
|2<br>3|1.5<br>2.2||7<br>10.5|2<br>2|**DC1-127D0NB-A20N**4<br>**DC1-12011NB-A20N**4|
|5|4||15|3|**DC1-12015NB-A20N**|
|0.5|0.37|200–240V three-phase in/|2.3|1|**DC1-322D3NN-A20N**|
|1|0.75|230V three-phase out|4.3|1|**DC1-324D3NN-A20N**|
|2|1.5||7|1|**DC1-327D0NN-A20N**|
|2|1.5||7|2|**DC1-327D0NB-A20N**4|
|3|2.2||10.5|2|**DC1-32011NB-A20N**4|
|5|4||18|3|**DC1-32018NB-A20N**4|
|1<br>2|0.75<br>1.5|380–480V three-phase in/<br>460V three-phase out|2.2<br>4.1|1<br>1|**DC1-342D2NN-A20N**4<br>**DC1-344D1NN-A20N**4|
|2|1.5||4.1|2|**DC1-344D1NB-A20N**4|
|3<br>5|2.2<br>4||5.8<br>9.5|2<br>2|**DC1-345D8NB-A20N**4<br>**DC1-349D5NB-A20N**4|
|7.5|5.5||14|3|**DC1-34014NB-A20N**4|
|10|7.5||18|3|**DC1-34018NB-A20N**4|
|15|11||24|3|**DC1-34024NB-A20N**4|
## _**Notes**_
1 These are constant torque/high overload rated drives.
- 2 For all applications, select the unit such that the motor current is less than or equal to the rated continuous output current.
- 3 Brake chopper circuit available as standard in frames 2 and 3.
- 4 RFI version available. Substitute with DC1-*** F** *-**** for this option.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-4**
Adjustable Frequency Drives
2.1
PowerXL DC1 Series Drives
**IP66 DC1 Series IP66 Enclosure Drives**[1]
|**IP66**||**DC1 Series IP66 Enclosure Drives**|**DC1 Series IP66 Enclosure Drives**|**DC1 Series IP66 Enclosure Drives**[1]|||||
|---|---|---|---|---|---|---|---|---|
||||||**100% Continuous**|**100% Continuous**|**Frame**||
||ha|**hp**2|**kW**|**Volts**|**Current In (A)**||**Size**3|**Catalog Number**|
|0.5<br>0.37<br>115V single-phase in/<br>115V single-phase out<br>7<br>1<br>**DC1-S17D0NN-A6SN**4<br>0.75<br>0.55<br>10.5<br>2<br>**DC1-S1011NB-A6SN**4<br>0.5<br>0.37<br>200–240V single-phase in/<br>4.3<br>1<br>**DC1-S24D3NN-A6SN**45<br>|~~rr~~<br>ae|||||||||
|s|ha|1<br>0.75<br>1.5<br>1.1<br>~~ee~~||200–240V single-phase out|7<br>1<br>**DC1-S27D0NN-A6SN**45<br>10<br>2<br>**DC1-S2011NB-A6SN**45<br>~~oo~~<br>~~co~~||||
|**IP66S**||0.5|0.37|115V single-phase in/|2.3||1|**DC1-1D2D3NN-A6SN**4|
||ha|1<br>0.75<br> ~~a~~||230V three-phase out|4.3<br>1<br>**DC1-1D4D3NN-A6SN**4<br>~~a~~||||
|Hl<br>eae!|l,|1.5<br>1.1<br>0.5<br>0.37<br>1<br>0.75<br>2<br>1.5<br> ~~oo~~||200–240V single-phase in/<br>230V three-phase out|5.8<br>2<br>**DC1-1D5D8NB-A6SN**4<br>2.3<br>1<br>**DC1-122D3NN-A6SN**45<br>4.3<br>1<br>**DC1-124D3NN-A6SN**45<br>7<br>1<br>**DC1-127D0NN-A6SN**45<br>~~a~~||||
|as||2|1.5||7<br>2<br>**DC1-127D0NB-A6SN**45<br>~~rs~~||||
|||3|2.2||10.5||2|**DC1-12011NB-A6SN**45|
|||5|4||15||3|**DC1-12015NB-A6SN**4|
|||0.5|0.37|200–240V three-phase in/|2.3||1|**DC1-322D3NN-A6SN**4|
|||1|0.75|230V three-phase out|4.3||1|**DC1-324D3NN-A6SN**4|
|||2|1.5||7||1|**DC1-327D0NN-A6SN**4|
|||2|1.5||7||2|**DC1-327D0NB-A6SN**45|
|||3|2.2||10.5||2|**DC1-32011NB-A6SN**45|
|||5|4||18||3|**DC1-32018NB-A6SN**45|
|||1|0.75|380–480V three-phase in/|2.2||1|**DC1-342D2NN-A6SN**45|
|||2|1.5|460V three-phase out|4.1||1|**DC1-344D1NN-A6SN**45|
|||2|1.5||4.1||2|**DC1-344D1NB-A6SN**45|
|||3|2.2||5.8||2|**DC1-345D8NB-A6SN**45|
|||5|4||9.5||2|**DC1-349D5NB-A6SN**45|
|||7.5|5.5||14||3|**DC1-34014NB-A6SN**45|
|||10|7.5||18||3|**DC1-34018NB-A6SN**45|
**2**
## _**Notes**_
- 1 These are constant torque/high overload rated drives.
- 2 For all applications, select the unit such that the motor current is less than or equal to the rated continuous output current.
- 3 Brake chopper circuit available as standard in frames 2 and 3.
- 4 Non-disconnect version available. Substitute with **-A66N** .
- 5 RFI version available. Substitute with DC1-*** F** *-**** for this option.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-5**
Adjustable Frequency Drives
2.1
PowerXL DC1 Series Drives
**2**
## **Accessories**
## **DC1 Series**
## **PC Communication Kit and Copy/Paste Module**
|**Description**|**Catalog Number**|
|---|---|
|Bluetooth copy/paste communication stick|**DX-COM-STICK**|
|USB PC connection kit|**DX-COM-PCKIT**|
## **Encoder Feedback Plug-In Option Module and Miscellaneous Cards**
|**and Miscellaneous Cards**||
|---|---|
|**Description**|**Catalog Number**|
|Local control/test option card|**DXC-EXT-LOCSIM**|
|HVACO drive running and tripped relay output card<br>Dual relay output card|**DXC-EXT-2RO1AO**<br>**DXC-EXT-2RO**|
|110V logic input card<br>230V logic input card|**DXC-EXT-IO110**<br>**DXC-EXT-IO230**|
## **Remote Keypad**
## **Extension Cables and Data Cable Splitter**
|**Description**|**Catalog Number**|
|---|---|
|RJ45 communication cable w/terminating resistor|**DX-CBL-TERM**|
|RS-485 data cable, RJ45, 0.5m|**DX-CBL-RJ45-0M5**|
|RS-485 data cable, RJ45, 1.0m|**DX-CBL-RJ45-1M0**|
|RS-485 data cable, RJ45, 3.0m|**DX-CBL-RJ45-3M0**|
|RS-485 three-way data cable splitter, RJ45|**DX-SPL-RJ45-3SL**|
|RS-485 data cable splitter, RJ45, (1 connector to 2 socket)|**DX-SPL-RJ45-2SL1PL**|
|**SmartWire Modules**||
|**Description**|**Catalog Number**|
|SmartWire-DT interface for DC1 IP20|**DX-NET-SWD3**|
## **SmartWire Modules**
## _**Note**_
> 1 Includes 1m RS-485 data cable.
|**Remote Keypad**||
|---|---|
|**Description**|**Catalog Number**|
|LED remote keypad—7-segment display, IP54 rated|**DX-KEY-LED**1|
|OLED remote keypad—full text display, multi-line text,|**DX-KEY-OLED**1|
|multi-language, IP54||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-6**
Adjustable Frequency Drives
2.1
PowerXL DC1 Series Drives
## **Technical Data and Specifications**
## **DC1 Series**
**2**
## _**Ratings**_
## **PowerXL DC1 Basic Controller IP20 Standard Ratings**
|**Description**|**Specification**|
|---|---|
|**Protections**||
|Overload protection|150% for 60s for every 600 seconds|
|Overvoltage protection|Yes|
|Undervoltage protection|Yes|
|Ground fault protection|Yes|
|Overtemperature|Yes|
|protection||
|Motor overload protection|Yes|
|Motor stall protection|Yes|
## **Programmable Parameters**
## **Description**
Built-in Help card 14 Standard operation parameters Reference scaling Programmable start and stop functions DC-brake at start and stop Programmable V/Hz curve Adjustable switching frequency Autorestart function after fault Protections and supervisions Power section fault indication External fault Fieldbus communication Second deceleration time Analog input range selection, signal scaling and filtering PI controller Skip frequencies
## _**Specifications**_
## **PowerXL DC1 Series Drives**
|**Description**<br>**Input Ratings**|**Specification**|
|---|---|
|Input voltage (Vin)|±10%|
|Input frequency (fin)|50/60 Hz (variation up to 48–62 Hz)|
|Connection to power|Maximum of one time every 30 seconds|
|**Output Ratings**<br>Output voltage|0 to Vin 1|
|Continuous output<br>current|Continuous rated current INat ambient temperature max.<br>122°F (50°C), 150% for 60 seconds, 175% for 2 seconds|
|Output frequency<br>Frequency resolution|0 to 500 Hz<br>0.1 Hz|
|Initial output current (IH)|175% for 2s for every 20 seconds<br>Torque depends on motor|
|**Control Characteristics**||
|Operation mode|U/f control, slip compensation|
|Switching frequency|4 to 32 kHz|
|Voltage reference|10 Vdc (max. 10 mA)|
|Field weakening point|0 to 500 Hz|
|Acceleration time<br>Deceleration time|0.1 to 600 seconds<br>0.1 to 600 seconds|
|**Brake Resistor (Minimum Values)**2||
|230V Series|FS2 and FS3 47 ohms|
|400V Series|FS2 100 ohms, FS3 47 ohms|
|**Ambient Conditions**||
|Ambient operating|+14°F (–10°C), no frost to +122°F (+50°C): Rated loadability IN|
|temperature|IP20—NEMA 0|
|Storage temperature|–40°F (–40°C) to +140°F (+60°C)|
|Relative humidity<br>Enclosure class|0 to 95% RH, noncondensing, non-corrosive, no dripping water<br>IP20 (FS1–FS3)|
## _**Notes**_
- 1 Exception: 115V single-phase in, 230V three-phase out.
- 2 Only FS2 and FS3 drives are equipped with brake chopper circuit.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-7**
Adjustable Frequency Drives
2.1
PowerXL DC1 Series Drives
## **Standards—DC1 Series**
## _**I/O Specifications**_
- **2** ● Digital inputs DI1–DI4 are programmable
- Digital, relay and analog outputs are programmable
Includes:
- Four inputs (two digital and two digital/analog)
- Analog inputs
- 4–20 mA
- 0–10V
- One output (analog or digital)
## _**Reliability**_
- Pretested components
- Computerized testing
- Final test with full load
- Conformal-coated boards
- Eaton’s Electrical Services & Systems: national network of AF drive specialists
- One relay output
- RS-485 interface
## **DC1 Series I/O Interface**
|**Terminal**|**Signal**<br>**Factory Preset**<br>**Description**|
|---|---|
|1|+24 Vdc<br>Control voltage for DI1–DI4<br>—<br>Maximum load 100 mA<br>Reference potential V|
|2|DI1<br>Digital Input 1<br>Start Enable FWD<br>8 to +30V (High, R1> 6 kΩ)|
|3|DI2<br>Digital Input 2<br>Start Enable REV<br>8 to +30V (High, R1> 6 kΩ)|
|4|DI3<br>Digital Input 3<br>Fixed frequency FF1<br>Digital: 8–30V (high)|
||AI2<br>Analog Input 2<br>Fixed frequency FF1<br>Analog: 0 to +10V (Ri>72 kΩ)<br>0/4–20 mA (Rß= 500 Ω)<br>Can be switched with parameter P16|
|5|+10 Vdc<br>Reference voltage, Output (+10V)<br>—<br>Maximum load 10 mA<br>Reference potential 0V|
|6|AI1<br>Analog Input 1<br>Frequency reference value1<br>(fixed frequency)<br>Analog: 0 to +10V (Ri>72 kΩ)<br>0/4–20 mA (Rß= 500 Ω)<br>Can be switched with parameter P16|
||DI4<br>Digital Input 5<br>Frequency reference value1<br>(fixed frequency)<br>Digital: 8–30V (high)|
|7|0V<br>Reference potential<br>—<br>0V = connection terminal 9|
|8|AO1<br>Analog Output 1<br>Output frequency<br>Analog: 0 to +10V, maximum 4–20 mA<br>Can be switched with parameter P-25|
||DO1<br>Digital Output 1<br>Output frequency<br>Digital: 8 to +24V|
|9|0V<br>Reference potential<br>—<br>0V connection terminal 7|
|10|K13<br>Relay 1, normally open contact<br>Active = RUN<br>Maximum switching load: 250 Vac/6A or 30 Vdc/5A|
|11|K14<br>Relay 1, normally open contact<br>Active = RUN<br>Maximum switching load: 250 Vac/6A or 30 Vdc/5A|
_**Note**_ 1 Programmable function.
**==> picture [134 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3 4 6 8<br>CPU<br>24V FWD REV FF1 f-Soll 0 to +10V/20 mA f-Out 0 to +10V/20 mA<br>+24V Out < 100 mA DI1 DI2 DI3 (AI2) AI1 (DI4) AO (DO)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-8**
Adjustable Frequency Drives PowerXL DC1 Series Drives
2.1
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **DC1, Sizes FS1–FS3, Degree of Protection IP20/NEMA 0**
**2**
**==> picture [505 x 587] intentionally omitted <==**
**----- Start of picture text -----**<br>
B2<br>Ø<br>Ø1<br>Ø2<br>B<br>B1<br>A1 C1<br>A C<br>Frame Weight<br>Size A A1 B B1 B2 C C1 Ø1 Ø2 lbs (kg)<br>FS1 3.19 (81.0) 1.97 (50.0) 7.24 (184.0) 6.69 (170.0) 0.28 (7.0) 4.88 (124.0) 0.16 (4.0) 0.24 (6.0) 0.47 (12.0) 2.43 (1.1)<br>FS2 4.21 (107.0) 2.95 (75.0) 9.09 (231.0) 8.46 (215.0) 0.31 (8.0) 5.98 (152.0) 0.20 (5.0) 0.24 (6.0) 0.47 (12.0) 5.73 (2.6)<br>FS3 5.16 (131.0) 3.94 (100.0) 10.75 (273.0) 10.04 (255.0) 0.33 (8.5) 6.89 (175.0) 0.20 (5.0) 0.24 (6.0) 0.47 (12.0) 8.82 (4.0)<br>DC1, Sizes FS1–FS3, Degree of Protection IP66/NEMA 4<br>Ø1<br>Ø2<br>B<br>B1<br>B1<br>A1<br>B2<br>A1 C1<br>A C<br>Frame Weight<br>Size A A1 B B1 B2 C C1 Ø1 Ø2 lbs (kg)<br>FS1 6.34 (161.0) 5.85 (148.5) 9.13 (232.0) 7.44 (189.0) 0.98 (25.0) 7.24 (184.0) 0.14 (3.5) 0.15 (4.0) 0.31 (8.0) 5.51 (2.5)<br>FS2 7.40 (188.0) 6.93 (176.0) 10.12 (257.0) 7.87 (200.0) 1.12 (28.5) 7.58 (192.0) 0.14 (3.5) 0.16 (4.2) 0.33 (8.5) 10.36 (4.7)<br>FS3 8.29 (210.5) 7.78 (197.5) 12.20 (310.0) 9.90 (251.5) 1.31 (33.4) 9.21 (234.0) 0.14 (3.5) 0.16 (4.2) 0.33 (8.5) 17.42 (7.9)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-9**
Adjustable Frequency Drives
PowerXL DC1 Series Drives
## 2.1
Approximate Dimensions in Inches (mm)
**2**
## **DC1, Sizes FS1–FS3, Degree of Protection IP66/NEMA 4, with Local Controls**
|||B<br>B1<br>B2|||||
|---|---|---|---|---|---|---|
||||||||
||A1<br>A||||||
||||||||
||||||||
|<br>**A**|**A1**<br>**B**<br>**B1**||||||
|6.34 (161.0)|5.85 (148.5)<br>9.13 (232.0)<br>7.44 (189.0)<br>0.98 (25.0)<br>7.24 (184.0)<br>0.14 (3.5)<br>0.15 (4.0)<br>0.31 (8.0)<br>6.17 (2.8)||||||
|7.40 (188.0)|6.93 (176.0)<br>10.12 (257.0)<br>7.87 (200.0)<br>1.12 (28.5)<br>7.58 (192.0)<br>0.14 (3.5)<br>0.16 (4.2)<br>0.33 (8.5)<br>11.02 (5.0)||||||
|8.29 (210.5)|7.78 (197.5)<br>12.20 (310.0)<br>9.90 (251.5)<br>1.31 (33.4)<br>9.21 (234.0)<br>0.14 (3.5)<br>0.16 (4.2)<br>0.33 (8.5)<br>18.08 (8.2)||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-10**
Adjustable Frequency Drives
2.2
PowerXL DA1 Series Drives
## **PowerXL DA1 Series Drives**
## **Contents**
|**Contents**||**2**|
|---|---|---|
|**_Description_**|**_Page_**||
|PowerXL DA1 Series Drives||**2**|
|Catalog Number Selection . . . . . . . . . . . . . . . .<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-12**<br>**V6-T2-13**|**2**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V6-T2-15**<br>**V6-T2-16**|**2**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-18**|**2**|
## **Product Description**
Eaton’s PowerXL™ DA1 variable frequency drives are the next generation of drives specifically engineered for today’s machinery applications.
DA1 is the perfect match for demanding OEM applications. High-performance processor, safe torque off, multiple fieldbus protocols including SmartWire-DT, sensorless vector control and the possibility to operate permanent magnet motors are sure to leave a lasting impression.
Models rated at 480 volts, three-phase, 50/60 Hz are available in sizes ranging from 1 to 15 hp. Models rated at 240 volts, single- or threephase, 50/60 Hz are available in sizes ranging from 0.5 to 7.5 hp. Models rated at 575 volts, three-phase, 50/60 Hz are available in sizes ranging from 1 to 20 hp.
## **Features**
- Compact, space-saving design
- Rugged and reliable—200% for 4s 50°C rated
- DIN rail and screw mountable (FS1 and FS2)
- Side-by-side installation
- Industry-leading efficiency delivers energy savings to the customer
- Integrated EMC filters make the unit suitable for commercial and industrial networks
- Communication cards that integrate into the drive—
- EtherNet/IP
- DeviceNet
- PROFIBUS-DP
- EtherCAT
- PROFINET
- Modbus TCP
- BACnet
- Brake chopper as standard in frames 2 and higher
- Temperature-controlled fan
- RS-485/Modbus[®] and CANopen™ as standard
- PID controller as standard
- Several fieldbus options
- SmartWire capability
- Removable I/O terminal blocks
- Contactor style power wiring
- 200% torque at zero speed
- Ability to run permanent magnet motors
- PLC programming
- Closed loop
- Conformal coated boards
## **Standards and Certifications**
## _**Product**_
- Complies with EN61800-3 (2004)
## _**EMC (At Default Settings)**_
- EMC Category C1, C2 and C3 at default settings (1m, 5m, 25m)
## _**Safety**_[1]
- 61800-5-1
- EN 60529
- CE
- UL
- cUL
- UkrSepro
- c-Tick
- RoHS compliant
## _**Note**_
- 1 See unit nameplate for more detailed approvals.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-11**
Adjustable Frequency Drives
2.2
PowerXL DA1 Series Drives
## **Catalog Number Selection**
**2**
## **DA1 Series Adjustable Frequency AC Drives**
**DA1 - 1 2 4D1 F B - A 20 C**
**==> picture [448 x 210] intentionally omitted <==**
**----- Start of picture text -----**<br>
Device Series Type<br>DA1 = Variable frequency drive, compact, Series 1 C = Coated printed circuit boards<br>( D = Drives, A = Advanced, 1 = Series 1)<br>Degree of Protection<br>Connection in Power Section 20 = IP20/NEMA 0<br>1 = Single-phase mains connection/three-phase motor connection 66 = IP66/NEMA 4<br>3 = Three-phase mains connection/three-phase motor connection 6S = IP66 with disconnect/NEMA 4<br>Mains Voltage Category Display Unit (Display)<br>2 = 230V (200–240V ±10%) A = LED display<br>4 = 400V (380–480V ±10%)<br>5 = 575V (500–600V ±10%)<br>Brake Chopper<br>B = Brake chopper<br>Rated<br>Operational Current<br>Examples— EMC (Radio Interference Suppression Filter)<br>2D2 = 2.2A F = Internal RFI filter<br>4D1 = 4.1A<br>024 = 24A<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-12**
Adjustable Frequency Drives
2.2
PowerXL DA1 Series Drives
## **Product Selection**
## **IP20**
**DA1 Series IP20 Enclosure Drives**[1]
**2**
|||||**100% Continuous**|**Frame**||
|---|---|---|---|---|---|---|
|**hp**|**hp**2|**kW**|**Volts**|**Current In (A)**|**Size**3|**Catalog Number**|
|1||0.75|200–240V single-phase in/|4.3|2|**DA1-124D3FB-A20C**|
|2||1.5|230V three-phase out|7|2|**DA1-127D0FB-A20C**|
|3||2.2||10.5|2|**DA1-12011FB-A20C**|
|1||0.75|200–240V three-phase in/|4.3|2|**DA1-324D3FB-A20C**|
|2||1.5|230V three-phase out|7|2|**DA1-327D0FB-A20C**|
|3||2.2||10.5|2|**DA1-32011FB-A20C**|
|5||4||18|3|**DA1-32018FB-A20C**|
|7.5||5.5||24|3|**DA1-32024FB-A20C**|
|1||0.75|380–480V three-phase in/|2.2|2|**DA1-342D2FB-A20C**|
|2||1.5|460V three-phase out|4.1|2|**DA1-344D1FB-A20C**|
|3||2.2||5.8|2|**DA1-345D8FB-A20C**|
|5||4||9.5|2|**DA1-349D5FB-A20C**|
|7.5||5.5||14|3|**DA1-34014FB-A20C**|
|10||7.5||18|3|**DA1-34018FB-A20C**|
|15||11||24|3|**DA1-34024FB-A20C**|
|1||0.75|500–600V three-phase in/|2.1|2|**DA1-352D1NB-A20C**|
|2||4.5|575V three-phase out|3.1|2|**DA1-353D1NB-A20C**|
|3||2.2||4.1|2|**DA1-354D1NB-A20C**|
|5||4||6.5|2|**DA1-356D5NB-A20C**|
|7.5||5.5||9|2|**DA1-359D0NB-A20C**|
|10||7.5||12|3|**DA1-35012NB-A20C**|
|15||11||17|3|**DA1-35017NB-A20C**|
|20||15||22|3|**DA1-35022NB-A20C**|
## _**Notes**_
- 1 These are constant torque/high overload rated drives.
- 2 For all applications, select the unit such that the motor current is less than or equal to the rated continuous output current.
- 3 Brake chopper circuit available as standard in frames 2 and 3.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-13**
Adjustable Frequency Drives
2.2
PowerXL DA1 Series Drives
**2** ~~“a~~
**==> picture [13 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
IP66<br>**----- End of picture text -----**<br>
## **IP66S**
## **DA1 Series IP66 Enclosure Drives**[1]
|||**100% Continuous**|**Frame**||
|---|---|---|---|---|
|**hp**2<br>**kW**<br>**Volts**<br>**Current In (A)**<br>**Size**3<br>**Catalog Number**<br>1<br>0.75<br>200–240V single-phase in/<br>230V three-phase out<br>4.3<br>2<br>**DA1-124D3FB-A6SC**4<br>2<br>1.5<br>7<br>2<br>**DA1-127D0FB-A6SC**4<br>3<br>2.2<br>10.5<br>2<br>**DA1-12011FB-A6SC**4<br>~~Cy~~<br>~~iw~~<br>~~ee~~<br>~~—---—--->;re~~<br>~~eT~~<br>~~993939800595~~|||||
|1<br>0.75|200–240V three-phase in/|4.3|2|**DA1-324D3FB-A6SC**4|
|2<br>1.5|230V three-phase out|7|2|**DA1-327D0FB-A6SC**4|
|3<br>2.2||10.5|2|**DA1-32011FB-A6SC**4|
|5<br>4<br>1<br>0.75|380–480V three-phase in/|18<br>2.2|3<br>2|**DA1-32018FB-A6SC**4<br>**DA1-342D2FB-A6SC**4|
|2<br>1.5<br>~~——~~|460V three-phase out|4.1<br>2<br>**DA1-344D1FB-A6SC**4<br>~~oo~~|||
|3<br>2.2<br>5<br>4<br>7.5<br>5.5<br>10<br>7.5<br>~~a~~||5.8<br>2<br>**DA1-345D8FB-A6SC**4<br>9.5<br>2<br>**DA1-349D5FB-A6SC**4<br>14<br>3<br>**DA1-34014FB-A6SC**4<br>18<br>3<br>**DA1-34018FB-A6SC**4<br>~~So~~|||
|1<br>0.75<br>2<br>4.5|500–600V three-phase in/<br>575V three-phase out|2.1<br>3.1|2<br>2|**DA1-352D1NB-A6SC**<br>**DA1-353D1NB-A6SC**|
|3<br>2.2||4.1|2|**DA1-354D1NB-A6SC**|
|5<br>4||6.5|2|**DA1-356D5NB-A6SC**|
|7.5<br>5.5||9|2|**DA1-359D0NB-A6SC**|
|10<br>7.5<br>15<br>11||12<br>17|3<br>3|**DA1-35012NB-A6SC**<br>**DA1-35017NB-A6SC**|
## _**Notes**_
- 1 These are constant torque/high overload rated drives.
- 2 For all applications, select the unit such that the motor current is less than or equal to the rated continuous output current.
- 3 Brake chopper circuit available as standard in frames 2 and 3.
- 4 Non-disconnect version available. Substitute with **-A66C** .
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-14**
Adjustable Frequency Drives
2.2
PowerXL DA1 Series Drives
## **Accessories**
## **DA1 Series**
**2**
**PC Communication Kit and Copy/Paste Module**
|**Description**|**Catalog Number**|
|---|---|
|Bluetooth copy/paste communication stick|**DX-COM-STICK**|
|USB PC connection kit|**DX-COM-PCKIT**|
## **Remote Keypad**
|**Remote Keypad**||
|---|---|
|**Description**|**Catalog Number**|
|LED remote keypad—7-segment display, IP54 rated<br>OLED remote keypad—full text display, multi-line text,|**DX-KEY-LED**1<br>**DX-KEY-OLED**1|
|multi-language, IP54||
## **Optional Communication Modules**
|**Description**|**Catalog Number**|
|---|---|
|DeviceNet plug-in interface module|**DX-NET-DEVICENET**|
|PROFIBUS-DP plug-in interface module|**DX-NET-PROFIBUS**|
|EtherNet/IP plug-in interface module|**DX-NET-ETHERNET-2**|
|EtherCAT plug-in interface module|**DX-NET-ETHERCAT-2**|
|PROFINET plug-in interface module|**DX-NET-PROFINET-2**|
|Modbus TCP plug-in interface module|**DX-NET-MODBUSTCP-2**|
|BACnet plug-in interface module|**DX-NET-BACNETIP-2**|
## **Encoder Feedback Plug-In Option Module and Miscellaneous Cards**
|**Encoder Feedback Plug-In Option**<br>**and Miscellaneous Cards**|**Module**|
|---|---|
|**Description**|**Catalog Number**|
|Relay output option module|**DXA-EXT-3RO**|
|Encoder feedback plug-in option module|**DXA-EXT-ENCOD**|
## **Extension Cables and Data Cable Splitter**
|**Description**|**Catalog Number**|
|---|---|
|RJ45 communication cable w/terminating resistor|**DX-CBL-TERM**|
|RS-485 data cable, RJ45, 0.5m|**DX-CBL-RJ45-0M5**|
|RS-485 data cable, RJ45, 1.0m|**DX-CBL-RJ45-1M0**|
|RS-485 data cable, RJ45, 3.0m<br>RS-485 three-way data cable splitter, RJ45|**DX-CBL-RJ45-3M0**<br>**DX-SPL-RJ45-3SL**|
|RS-485 data cable splitter, RJ45, (1 connector to 2 socket)|**DX-SPL-RJ45-2SL1PL**|
|**SmartWire Modules**||
|**Description**|**Catalog Number**|
|SmartWire-DT interface for DA1 IP20|**DX-NET-SWD1**|
## **SmartWire Modules**
## _**Note**_
> 1 Includes 1m RS-485 data cable.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-15**
Adjustable Frequency Drives
2.2
PowerXL DA1 Series Drives
**2**
## **Technical Data and Specifications**
## **DA1 Series**
## _**Ratings**_
## **PowerXL DA1 Basic Controller IP20 Standard Ratings**
|**Description**<br>**Protections**|**Specification**|
|---|---|
|Overload protection|150% for 60s for every 600 seconds|
|Overvoltage protection|Yes|
|Undervoltage protection|Yes|
|Ground fault protection<br>Overtemperature|Yes<br>Yes|
|protection||
|Motor overload protection|Yes|
|Motor stall protection|Yes|
## **Programmable Parameters**
**Description** Built-in Help card 14 Standard operation parameters Reference scaling Programmable start and stop functions DC-brake at start and stop Programmable V/Hz curve Adjustable switching frequency Autorestart function after fault Protections and supervisions Power section fault indication External fault Fieldbus communication Safe torque off (STO) function Analog input range selection, signal scaling and filtering PI controller Skip frequencies
## _**Specifications**_
## **PowerXL DA1 Series Drives**
|**Description**|**Specification**|
|---|---|
|**Input Ratings**||
|Input voltage (Vin)|±10%|
|Input frequency (fin)|50/60 Hz (variation up to 48–62 Hz)|
|Connection to power|Maximum of one time every 30 seconds|
|**Output Ratings**||
|Output voltage|0 to Vin 1|
|Continuous output|Continuous rated current INat ambient temperature max. 122°F (50°C),|
|current|150% for 60 seconds, 200% for 4 seconds|
|Output frequency|0 to 500 Hz|
|Frequency resolution|0.1 Hz|
|Initial output current (IH)|200% for 4s for every 40 seconds|
||Torque depends on motor|
|**Control Characteristics**||
|Operation mode|U/f control, slip compensation, sensorless vector control (SLV),|
||vector control with feedback (CLV)|
|Switching frequency|4 to 32 kHz|
|Voltage reference|10 Vdc (max. 10 mA)|
|Field weakening point|0 to 500 Hz|
|Acceleration time|0.1 to 600 seconds|
|Deceleration time|0.1 to 600 seconds|
|**Brake Resistor (Minimum Values)**2||
|230V Series|FS2 and FS3 15 ohms|
|400V Series|FS2 33 ohms, FS3 22 ohms|
|**Ambient Conditions**||
|Ambient operating|+14°F (–10°C), no frost to +122°F (+50°C): Rated loadability IN|
|temperature|IP20—NEMA 0|
|Storage temperature|–40°F (–40°C) to +140°F (+60°C)|
|Relative humidity|0 to 95% RH, noncondensing, non-corrosive, no dripping water|
|Enclosure class|IP20 (FS1–FS3)|
## _**Notes**_
> 1 Exception: 115V single-phase in, 230V three-phase out.
> 2 Only FS2 and FS3 drives are equipped with brake chopper circuit.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-16**
Adjustable Frequency Drives
2.2
PowerXL DA1 Series Drives
## **Standards—DA1 Series**
## _**I/O Specifications**_
- Digital inputs DI1–DI5 are programmable
- Digital, relay and analog outputs are programmable
Includes:
- Five inputs (three digital and two digital/analog)
- Analog inputs
- 4–20 mA
- 0–10V
- Two outputs (analog or digital)
## _**Reliability**_
- Pretested components
- Computerized testing
- Final test with full load
- Conformal-coated boards
- Eaton’s Electrical Services & Systems: national network of AF drive specialists
**2**
- Two relay outputs
- RS-485 interface
## **DA1 Series I/O Interface**
|**DA1 Series I/O Interface**|**DA1 Series I/O Interface**|
|---|---|
|**Terminal**<br>**Signal**<br>**Factory Preset**<br>**Description**||
|1|+24 Vdc<br>Control voltage for DI1–DI5<br>—<br>Maximum load 100 mA<br>Reference potential V|
|2|DI1<br>Digital Input 1<br>Start Enable FWD1<br>8 to +30V (High, R1> 6 kΩ)|
|3|DI2<br>Digital Input 2<br>Start Enable REV1<br>8 to +30V (High, R1> 6 kΩ)|
|4|DI3<br>Digital Input 3<br>Fixed frequency FF1/FF21<br>8 to +30V (High, R1> 6 kΩ)|
|5|+10 Vdc<br>Reference voltage, Output (+10V)<br>—<br>Maximum load 10 mA<br>Reference potential 0V|
|6|AI1<br>Analog Input 1<br>Frequency reference value1<br>Analog: 0 to +10V (Ri>72 kΩ)<br>0/4–20 mA (Ri= 500 Ω)<br>Can be switched with parameter P2-30|
||DI4<br>Digital Input 5<br>Frequency reference value1<br>Digital: 8–30V (high)|
|7|0V<br>Reference potential<br>—<br>0V = connection terminal 9|
|8|AO1<br>Analog Output 1<br>Output frequency<br>Analog: 0 to +10V, maximum 20 mA<br>Can be switched with parameter P2-11|
||DO1<br>Digital Output 1<br>Output frequency<br>Digital: 8–24V|
|9|0V<br>Reference potential<br>—<br>0V connection terminal 7|
|10|DI4<br>Digital Input 4<br>Fixed frequency FF21<br>Analog: 0 to +10V (Ri>72 kΩ)<br>0/4–20 mA (Ri= 500 Ω)<br>Can be switched with parameter P2-30|
||AI2<br>Analog Input 2<br>Fixed frequency FF21<br>Digital: 8–30V (high)|
|11|AO2<br>Analog output 2<br>Output current1<br>Analog: 0 to +10V, maximum 4–20 mA<br>Can be switched with parameter P2-11|
||DO2<br>Digital output 2<br>Output current1<br>Digital: 8–24V|
|12|STO+<br>Safe Torque Off +<br>—<br>Enable = +24V|
|13|STO-<br>Safe Torque Off –<br>—<br>Enable = 0V|
|14|K11<br>Relay 1, changeover contact<br>Active = FAULT1<br>Maximum switching load: 250 Vac/6A or 30 Vdc/5A|
|15|K14<br>Relay 1, changeover contact (N/O)<br>Active = FAULT1<br>Maximum switching load: 250 Vac/6A or 30 Vdc/5A|
|16|K12<br>Relay 1, changeover contact (N/C)<br>Active = FAULT1<br>Maximum switching load: 250 Vac/6A or 30 Vdc/5A|
|17|K23<br>Relay 2, N/O contact<br>Active = FAULT1<br>Maximum switching load: 250 Vac/6A or 30 Vdc/5A|
|18|K24<br>Relay 2, N/C contact<br>Active = FAULT1<br>Maximum switching load: 250 Vac/6A or 30 Vdc/5A|
|**_Note_**<br>1 Programmable function.<br>2<br>DI1<br>FWD<br>+24V<br>4<br>DI3<br>FF1/FF2<br>3<br>DI2<br>REV<br>10<br>DI4<br>(AI2)<br>FF2<br>1<br>+24V Out<br>< 100 mA<br>6<br>AI1<br>(DI5)<br>CPU<br>8<br>AO1<br>(DO1)<br>f-Out<br>0 to +10V/20 mA<br>f-Soll<br>0 to +10V/20 mA<br>11<br>AO2<br>(DO2)<br>A-Out<br>0 to +10V/20 mA||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-17**
Adjustable Frequency Drives
PowerXL DA1 Series Drives
## 2.2
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2**
## **DA1, Sizes FS2 and FS3, Degree of Protection IP20/NEMA 0**
**==> picture [505 x 574] intentionally omitted <==**
**----- Start of picture text -----**<br>
B2<br>Ø<br>Ø1<br>Ø2<br>B<br>B1<br>A1 C1<br>A C<br>Frame Weight<br>Size A A1 B B1 B2 C C1 Ø1 Ø2 lbs (kg)<br>FS2 4.21 (107.0) 2.95 (75.0) 9.09 (231.0) 8.46 (215.0) 0.31 (8.0) 7.32 (186.0) 0.20 (5.0) 0.24 (6.0) 0.47 (12.0) 3.97 (1.8)<br>FS3 5.16 (131.0) 3.94 (100.0) 10.75 (273.0) 10.04 (255.0) 0.33 (8.5) 8.03 (204.0) 0.20 (5.0) 0.24 (6.0) 0.47 (12.0) 7.72 (3.5)<br>DA1, Sizes FS2 and FS3, Degree of Protection IP66/NEMA 4<br>Ø1<br>Ø2<br>B<br>B1<br>B1<br>A1<br>B2<br>A1 C1<br>A C<br>Frame Weight<br>Size A A1 B B1 B2 C C1 Ø1 Ø2 lbs (kg)<br>FS2 7.40 (188.0) 6.93 (176.0) 10.12 (257.0) 7.87 (200.0) 0.79 (20.0) 9.42 (239.3) 0.14 (3.5) 0.16 (4.2) 0.33 (8.5) 10.4 (4.5)<br>FS3 8.29 (211.0) 7.78 (198.0) 12.20 (310.0) 9.90 (252.0) 0.98 (25.0) 10.48 (266.3) 0.14 (3.5) 0.16 (4.2) 0.33 (8.5) 15.9 (7.0)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-18**
Adjustable Frequency Drives
2.2
PowerXL DA1 Series Drives
Approximate Dimensions in Inches (mm)
## **DA1, Sizes FS2 and FS3, Degree of Protection IP66/NEMA 4, with Local Controls**
**==> picture [505 x 305] intentionally omitted <==**
**----- Start of picture text -----**<br>
Ø1<br>Ø2<br>B<br>B1<br>B1<br>A1<br>B2<br>A1 C1<br>A C<br>Frame Weight<br>Size A A1 B B1 B2 C C1 Ø1 Ø2 lbs (kg)<br>FS2 7.40 (188.0) 6.93 (176.0) 10.12 (257.0) 7.87 (200.0) 0.79 (20.0) 9.42 (239.3) 0.14 (3.5) 0.16 (4.2) 0.33 (8.5) 10.6 (4.8)<br>FS3 8.29 (211.0) 7.78 (198.0) 12.20 (310.0) 9.90 (252.0) 0.98 (25.0) 10.48 (266.3) 0.14 (3.5) 0.16 (4.2) 0.33 (8.5) 16.1 (7.3)<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-19**
Adjustable Frequency Drives
2.3
M-Max Series Drives
**2** ~~mS~~
**==> picture [140 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
M-Max Series Drives for Machinery Applications<br>**----- End of picture text -----**<br>
## **Product Description**
Eaton’s M-Max™ Series Sensorless Vector Adjustable Frequency AC Drives are the next generation of drives specifically engineered for today’s machinery applications. These microprocessor-based drives have standard features that can be programmed to tailor the drive’s performance to suit a wide variety of application requirements. The M-Max product line uses a 32-bit microprocessor and insulated gate bipolar transistors (IGBTs) that provide quiet motor operation, high motor efficiency, and smooth lowspeed performance. The size and simplicity of the M-Max make it ideal for hassle-free installation. Models rated at 575 volts, three-phase, 50/60 Hz are available in sizes ranging from 1 to 7-1/2 hp. Models rated at 480 volts, three-phase, 50/60 Hz are available in sizes ranging from 1/2 to 25 hp. Models rated at 240 volts, single- or three-phase, 50/60 Hz are available in sizes ranging from 1/4 to 15 hp. Models rated at 115 volts, single-phase, 50/60 Hz are available in the 1/4 to 1-1/2 hp size range.
The standard drive includes a digital display, and operating and programming keys on a visually appealing, efficient application programming interface. The display provides drive monitoring, as well as adjustment and diagnostic information. The keys are used for digital adjustment and programming of the drive, as well as for operator control. Separate terminal blocks for control and power wiring are provided for customer connections.
## **Contents**
**==> picture [243 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|M-Max Series Drives|
|Catalog Number Selection . . . . . . . . . . . . . . . .|V6-T2-21|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V6-T2-22|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|V6-T2-23|
|Technical Data and Specifications . . . . . . . . . .|V6-T2-24|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V6-T2-26|
**----- End of picture text -----**<br>
## **Features**
- Ease of use—preset ● Integrated EMC filters application macros, startup make the unit suitable for wizard, diagnostic commercial and industrial capabilities networks
- Compact, space-saving ● IP21 as standard, option design for NEMA[®] 1 (FS4 and FS5)
- Rugged and reliable— ● IP20 as standard, option 150% torque for one for IP21 and NEMA 1 minute, 50C rated, (FS1–FS3) conformal coated boards ● Brake chopper as standard
- ● DIN rail and screw in three-phase, applications mountable of frames 2 (FS2) and
- ● larger
- Side-by-side installation
- Temperature-controlled fan
- Industry leading efficiency delivers energy savings to ● RS-485/Modbus[®] as the customer standard
- Integrated 5% DC choke ● PID controller as standard (FS4 and FS5) ● Several fieldbus options
- PID controller as standard
## **Standards and Certifications**
## _**EMC (At Default Settings)**_
## _**Product**_
- Complies with EN61800-3 ● EMC Category C2, C3, and (2004) C4 (Level H): With an internal RFI filter option
## _**Safety**_[1]
- 61800-5-1
- EN60204-1
- CE
- UL
- cUL
- IEC
- RoHS compliant
_**Note**_
- 1 See unit nameplate for more detailed approvals.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-20**
Adjustable Frequency Drives
2.3
M-Max Series Drives
## **Catalog Number Selection**
**==> picture [488 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
–<br>MMX 1 1 AA 1D1 F 0 0<br>Description Option<br>MMX = Base catalog number Phase Enclosure Class 0 = Full version<br>1 = Single-phase 0 = NEMA 0 or IP20<br>3 = Three-phase<br>Voltage Software Output Current EMC Filter<br>1 = 120V 4 = 480V Designation Series 1D6 = 1.6A F = Filter<br>2 = 230V 5 = 575V AA 010 = 10A N = No filter<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-21**
Adjustable Frequency Drives
2.3
## M-Max Series Drives
## **Product Selection**
**2**
## **M-Max M-Max Basic Controller**
|**M-Max Basic Controller**|**M-Max Basic Controller**|||||
|---|---|---|---|---|---|
|||**100% Continuous**|**Nominal Input**|**Frame**||
|**hp**1|**Volts**2|**Current IN (A)**|**Current (A)**|**Size**|**Catalog Number**|
|1/4|100–120V single-phase in|1.7|9.2|FS2|**MMX11AA1D7N0-0**|
|1/2<br>3/4|230V three-phase out|2.4<br>2.8|11.6<br>12.4||**MMX11AA2D4N0-0**<br>**MMX11AA2D8N0-0**|
|1<br>1-1/2||3.7<br>4.8|15<br>16.5|FS3|**MMX11AA3D7N0-0**<br>**MMX11AA4D8N0-0**|
|1/4<br>1/2|200–240V single-phase in<br>230V three-phase out|1.7<br>2.4|4.2<br>5.7|FS1|**MMX12AA1D7F0-0**3<br>**MMX12AA2D4F0-0**3|
|3/4||2.8|6.6||**MMX12AA2D8F0-0**3|
|1||3.7|8.3|FS2|**MMX12AA3D7F0-0**3|
|1-1/2||4.8|11.2||**MMX12AA4D8F0-0**3|
|2<br>3||7<br>9.6|14.1<br>15.8|FS3|**MMX12AA7D0F0-0**3<br>**MMX12AA9D6F0-0**3|
|1/4<br>1/2|200–240V three-phase in<br>230V three-phase out|1.7<br>2.4|2.7<br>3.5|FS1|**MMX32AA1D7N0-0**<br>**MMX32AA2D4N0-0**|
|3/4||2.8|3.8||**MMX32AA2D8N0-0**|
|1||3.7|4.3|FS2|**MMX32AA3D7N0-0**|
|1-1/2||4.8|6.8||**MMX32AA4D8N0-0**|
|2<br>3||7<br>11|8.4<br>13.4|FS3|**MMX32AA7D0N0-0**<br>**MMX32AA011N0-0**|
|5||17|17|FS4|**MMX32AA017F0-0**4|
|7-1/2||25|25||**MMX32AA025F0-0**4|
|10||31|31|FS5|**MMX32AA031F0-0**4|
|15||38|38||**MMX32AA038F0-0**4|
|1/2|380–480V three-phase in|1.3|2.2|FS1|**MMX34AA1D3F0-0**3|
|3/4<br>1|460V three-phase out|1.9<br>2.4|2.8<br>3.2||**MMX34AA1D9F0-0**3<br>**MMX34AA2D4F0-0**3|
|1-1/2<br>2||3.3<br>4.3|4<br>5.6|FS2|**MMX34AA3D3F0-0**3<br>**MMX34AA4D3F0-0**3|
|3||5.6|7.3||**MMX34AA5D6F0-0**3|
|4||7.6|9.6|FS3|**MMX34AA7D6F0-0**3|
|5||9|11.5||**MMX34AA9D0F0-0**3|
|7-1/2||12|14.9||**MMX34AA012F0-0**3|
|10||14|18.7||**MMX34AA014F0-0**3|
|10<br>15||16<br>23|16<br>23|FS4|**MMX34AA016F0-0**4<br>**MMX34AA023F0-0**4|
|20||31|31|FS5|**MMX34AA031F0-0**4|
|25||38|38||**MMX34AA038F0-0**4|
|1|575V three-phase in|1.7|2.0|FS3|**MMX35AA1D7N0-0**|
|2|575V three-phase out|2.7|3.6||**MMX35AA2D7N0-0**|
|3||3.9|5.0||**MMX35AA3D9N0-0**|
|5<br>7-1/2||6.1<br>9.0|7.6<br>10.4||**MMX35AA6D1N0-0**<br>**MMX35AA9D0N0-0**|
## _**Notes**_
- 1 Horsepower ratings are based on the use of a 240V, 460V, and 575V NEMA B, four- or six-pole squirrel cage induction motor and are for reference only. Units are to be selected such that the motor current is less than or equal to the MMX rated continuous output current.
- 2 For 208V, 380V, or 415V applications, select the unit such that the motor current is less than or equal to the MMX rated continuous output current.
- 3 Units are also available without EMC filters. Substitute -N0-0 for this option.
- 4 Units are also available without EMC filters and 5% DC choke. Substitute -N0-0 for this option.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-22**
Adjustable Frequency Drives
2.3
M-Max Series Drives
## **Accessories**
## **M-Max Copy/Paste Module**
|**M-Max Copy/Paste Module**||
|---|---|
|**Description**|**Catalog Number**|
|Module is plugged onto the front of the drive to provide: upload/download of all parameters,|**MMX-COM-PC**|
|direct link to a PC via USB interface for parameter assignment via MaxConnect software, and||
|copying of parameters for a series of devices or when exchanging devices. No PC required||
**2**
## **PC Cable**
|**PC Cable**||
|---|---|
|**Description**|**Catalog Number**|
|Remote download USB to RJ-45 cable with software driver disk|**REM-USB-DOWN**|
## **NEMA Type 1 Kits**[1]
|**NEMA Type 1 Kits**1||
|---|---|
|**Description**|**Catalog Number**|
|NEMA Type 1 and IP21 kit for frame 1|**MMX-IP21-FS1**|
|NEMA Type 1 and IP21 kit for frame 2|**MMX-IP21-FS2**|
|NEMA Type 1 and IP21 kit for frame 3|**MMX-IP21-FS3**|
|NEMA Type 1 for frame 4|**MMX-CKIT-FS4**|
|NEMA Type 1 for frame 5|**MMX-CKIT-FS5**|
## **Optional Communication Modules**[2]
|**Optional Communication Modules**2||
|---|---|
|**Description**|**Catalog Number**|
|Communication adapter kit (FS1–FS3)|**MMX-NET-XA**|
|Communication adapter kit (FS4 and FS5)|**MMX-NET-XA-45**|
|PROFIBUS DP network card with serial connection|**XMX-NET-PS-A**|
|PROFIBUS DP network card with Sub-D connection|**XMX-NET-PD-A**|
|DeviceNet network card|**XMX-NET-DN-A**|
## **Remote Keypad**[3]
|**Remote Keypad**3||
|---|---|
|**Description**|**Catalog Number**|
|Keypad, bezel and cable|**OPTRMT-BP-HMAX**|
|Remote copy/paste keypad|**MMX-REMKEY-TEXT**|
|VFD adapter|**MMX-ADAPTER-RJ45**|
## _**Notes**_
> 1 NEMA Type 1 kit provides conduit entry plate.
> 2 Additional input and output reactors are available. Consult Eaton representative for a complete listing.
> 3 All three components are required for remote keypad operation.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-23**
Adjustable Frequency Drives
2.3
M-Max Series Drives
## **Technical Data and Specifications**
**2**
## **Ratings**
## **M-Max Basic Controller IP20 Standard Ratings**
|**Description**|**Specification**|
|---|---|
|**Protections**||
|Overcurrent protection|Trip limit 4.0 x IHinstantaneously|
|Overvoltage protection|115/230V series: 437 Vdc; 400V series: 874 Vdc;<br>575V series: 1048 Vdc trip level|
|Undervoltage protection|115/230V series: 183 Vdc; 400V series: 333 Vdc;<br>575V series: 460 Vdc trip level|
|Ground fault protection|Ground fault is tested before every start. In case of ground fault in|
||motor or motor cable, only the frequency converter is protected|
|Overtemperature|Yes|
|protection||
|Motor overload protection|Yes|
|Motor stall protection|Yes|
|Motor underload protection|Yes|
## **Programmable Parameters**
## **Description**
Application macros: basic, pump, fan and high load (hoist) Programmable start/stop and reverse signal logic (sinking or sourcing) Reference scaling Programmable start and stop functions DC-brake at start and stop Programmable V/Hz curve Adjustable switching frequency Autorestart function after fault Protections and supervisions (all fully programmable; off, warning, fault) Current signal input fault External fault Fieldbus communication Eight preset speeds Analog input range selection, signal scaling and filtering PID controller Skip frequencies
## **Specifications**
## **M-Max Series Drives**
|**Description**|**Specification**|
|---|---|
|**Input Ratings**||
|Input voltage (Vin)|+10%/–15%|
|Input frequency (fin)|50/60 Hz (variation up to 45–66 Hz)|
|Connection to power|Once per minute or less (typical operation)|
|**Output Ratings**||
|Output voltage|0 to Vin 1|
|Continuous output|Continuous rated current INat ambient temperature max.|
|current|122°F (50°C), overload 1.5 x INmax. 1 min/10 min|
|Output frequency|0 to 320 Hz|
|Frequency resolution|0.01 Hz|
|Initial output current (IH)|Current 2 x INfor 2 seconds in every 20-second period|
||Torque depends on motor|
|**Control Characteristics**||
|Control method|Frequency control (V/Hz) open loop or sensorless vector control|
|Switching frequency|1.5 to 16 kHz; default 4 kHz|
|Frequency reference|Analog input: resolution 0.1% (10-bit), accuracy ± 1% V/Hz|
||Panel reference: resolution 0.01 Hz|
|Field weakening point|30 to 320 Hz|
|Acceleration time|0 to 3000 sec|
|Deceleration time|0 to 3000 sec|
|Braking torque|DC brake: 30% x Tn(without brake option)|
|**Brake Resistor (Minimum Values)**2||
|230V Series|FS2 35 ohms and FS3 26 ohms, FS4 14 ohms, FS5 9 ohms|
|400V Series|FS2 75 ohms and FS3 54 ohms, FS4 28 ohms, FS5 17 ohms|
|575V Series|FS3 103 ohms|
|**Ambient Conditions**||
|Ambient operating|14°F (–10°C), no frost to 122°F (+50°C): Rated loadability IN|
|temperature||
|Storage temperature|–40°F (–40°C) to 158°F (70°C)|
|Relative humidity|0 to 95% RH, noncondensing, non-corrosive, no dripping water|
|Air quality|Chemical vapors: IEC 721-3-3, unit in operation, Class 3C2; Mechanical|
||particles: IEC 721-3-3, unit in operation, Class 3S2|
|Altitude|100% load capacity (no derating) up to 3280 ft (1000m);|
||1% derating for each 328 ft (100m) above 3280 ft (1000m);|
||max. 6560 ft (2000m)|
|Vibration|EN 60068-2-6; 3 to 150 Hz, displacement amplitude 1 mm (peak) at 3 to|
||15.8 Hz, max. acceleration amplitude 1G at 15.8 to 150 Hz|
|Shock|EN 50178, IEC 68-2-27 UPS Drop test (for applicable UPS weights);|
||storage and shipping: max. 15G, 11 ms (in package)|
|Enclosure class|IP20 (FS1–FS3)|
||IP21 (FS4 and FS5)|
## _**Notes**_
> 1 Exception: 115V single-phase in, 230V three-phase out.
> 2 Only three-phase FS2 and FS3 drives are equipped with brake chopper circuit.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-24**
Adjustable Frequency Drives
2.3
M-Max Series Drives
## **Standards**
## _**I/O Specifications**_
- Digital inputs DI1–DI6 are freely programmable. The user can assign multiple functions to a single input
- Digital, relay, and analog outputs are freely programmable
Includes:
- Six digital inputs
- Two analog inputs
- 4–20 mA
- 0–10V
- One analog output
- One digital output
## _**Reliability**_
- Pretested components
- Computerized testing
- Final test with full load
- Conformal-coated boards
- Eaton’s Electrical Services & Systems: national network of AF drive specialists
**2**
- Two relay outputs
- RS-485 interface
## **M-Max I/O Interface**
|Analog<br>OUT<br>AUTOGEN<br>Ref<br>Current|Analog<br>OUT<br>AUTOGEN<br>Ref<br>Current|Analog<br>OUT<br>AUTOGEN<br>Ref<br>Current|||||**Terminal**<br>**Signal**<br>**Factory Preset**<br>**Description**|**Terminal**<br>**Signal**<br>**Factory Preset**<br>**Description**|
|---|---|---|---|---|---|---|---|---|
||||||||~~1~~<br>+10V<br>Ref. output voltage<br>—<br>Maximum load 10 mA||
||||||||||
||||||||~~2~~<br>AI1<br>Analog signal in 1<br>Freq. referenceP)<br>0–+10V Ri = 200k ohms [min.]||
||||||||3<br>GND<br>I/O signal ground<br>—<br>—||
||||||||||
||||||||6<br>24V<br>24V outut for DIs<br>—<br>±20% max load 50 mA||
||TOGEN<br>f<br>rrent||||||p<br>, .||
||||||||7<br>GND<br>I/O signal ground<br>—<br>—||
||||||||8<br>DI1<br>Digital input 1<br>Start forwardP)<br>0–+30V Ri = 12k ohms min.||
||||||||||
||||||||9<br>DI2<br>Digital input 2<br>Start reverseP)<br>—||
||||||||||
||||||||10<br>DI3<br>Digital input 3<br>Preset speedP)<br>—||
||||||||||
||||||||A<br>A<br>RS-485 signal A<br>FB communication<br>—||
||||||||B<br>B<br>RS-485 signal B<br>FB communication<br>—||
||||||||4<br>AI2<br>Analog signal in 2<br>PI actual valueP)<br>0[4]–20 mA, Ri = 200k ohms||
||||||||||
||||||||5<br>GND<br>I/O signal ground<br>—<br>—||
||alog<br>T||||||||
||||||||13<br>GND<br>I/O signal ground<br>—<br>—||
||||||||14<br>DI4<br>Digital input 4<br>Preset speed B1P)<br>0–+30V Ri = 12k ohms min.||
||||||||||
||||||||15<br>DI5<br>Digital input 5<br>Fault resetP)<br>0–+30V Ri = 12k ohms min.||
||||||||||
||||||||16<br>DI6<br>Digital input 6<br>Disable PI contr.P)<br>0–+30V Ri = 12k ohms min.||
||||||||||
||||||||18<br>AO<br>Analog output<br>Output frequencyP)<br>0(2)–10V, RL = 500 ohms||
||||||||<br> <br>||
||||||||20<br>DO<br>Digital signal out<br>Active = READYP)<br>Open collector, max. load 48V/50 mA||
||||||||22<br>RO11|Relay out 1<br>Active = RUNP)<br>Max. switching load: 250 Vac/2A or 250 Vdc/0.4A|
||||||||||
||||||||23<br>RO12||
||||||||24<br>RO21|Relay out 2<br>Active = FAULTP)<br>Max. switching load: 250 Vac/2A or 250 Vdc/0.4A|
||||||||25<br>RO22||
||||||||||
||||||||||
||||||||26<br>RO23||
## _**Note**_
P) Parameter-selectable function.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-25**
Adjustable Frequency Drives
M-Max Series Drives
## 2.3
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2**
## **Dimensions and Frame Sizes, FS1–FS3 (FS = Frame Size)**
**==> picture [243 x 227] intentionally omitted <==**
**----- Start of picture text -----**<br>
a a<br>a1 a1<br>FS1<br>FS2<br>b1 b<br>b1 b<br>**----- End of picture text -----**<br>
**==> picture [124 x 267] intentionally omitted <==**
**----- Start of picture text -----**<br>
a<br>a1<br>b1 b<br>**----- End of picture text -----**<br>
**==> picture [11 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FS3<br>**----- End of picture text -----**<br>
**==> picture [99 x 143] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.28 in<br>(7 mm)<br>c<br>b2<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-26**
Adjustable Frequency Drives
2.3
M-Max Series Drives
Approximate Dimensions in Inches (mm)
## **Dimensions and Frame Sizes, FS4 and FS5 (FS = Frame Size)**
**==> picture [357 x 448] intentionally omitted <==**
**----- Start of picture text -----**<br>
a<br>0.28<br>a1<br>(7.0)<br>Ø<br>c<br>Ø1<br>a1<br>Ø2<br>b1 b b2<br>b1<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-27**
Adjustable Frequency Drives
2.3
M-Max Series Drives
## **Dimensions and Frame Sizes**
**2**
||**Approximate**|**Dimensions in inches (mm)**|**Dimensions in inches (mm)**||||||**Installation**|
|---|---|---|---|---|---|---|---|---|---|
|**Part Number**|**a**|**a1**|**b**|**b1**|**b2**|**c**|**Ø, Ø1**|**Ø2**|**Size**|
|**MMX12AA1D7_**|2.60|1.50|6.30|5.79|1.26|4.02|0.18|—|FS1|
|**MMX12AA2D4_**<br>**MMX12AA2D8_**|(66)|(38)|(160)|(147)|(32)|(102)|(4.5)|||
|**MMX32AA1D7_**<br>**MMX32AA2D4_**||||||||||
|**MMX32AA2D8_**<br>**MMX34AA1D3_**||||||||||
|**MMX34AA1D9_**||||||||||
|**MMX34AA2D4_**||||||||||
|**MMX11AA1D7_**|3.54|2.46|7.68|7.17|1.26|4.14|2.17|—|FS2|
|**MMX11AA2D4_**<br>**MMX11AA2D8_**|(90)|(62.5)|(195)|(182)|(32)|(105)|(5.5)|||
|**MMX11AA3D7_**<br>**MMX12AA3D7_**||||||||||
|**MMX12AA4D8_**||||||||||
|**MMX12AA7D0_**||||||||||
|**MMX32AA3D7_**||||||||||
|**MMX32AA4D8_**<br>**MMX32AA7D0_**||||||||||
|**MMX34AA3D3_**<br>**MMX34AA4D3_**||||||||||
|**MMX34AA5D6_**||||||||||
|**MMX11AA4D8_**|3.94|2.95|9.96|9.53|1.34|4.41|2.17|—|FS3|
|**MMX12AA9D6_**<br>**MMX32AA011_**|(100)|(75)|(253)|(242)|(34)|(112)|(5.5)|||
|**MMX34AA7D6_**<br>**MMX34AA9D0_**||||||||||
|**MMX34AA012_**<br>**MMX34AA014_**||||||||||
|**MMX35AA1D7_**||||||||||
|**MMX35AA2D7_**||||||||||
|**MMX35AA3D9_**||||||||||
|**MMX35AA6D1_**<br>**MMX35AA9D0_**||||||||||
|**MMX32AA012_**<br>**MMX32AA017_**|6.50<br>(165.0)|5.51<br>(140.0)|14.57<br>(370.0)|13.82<br>(351.0)|13.27<br>(337.0)|6.61<br>(168.0)|0.28<br>(7.0)|0.55<br>(14.0)|FS4|
|**MMX32AA025_**||||||||||
|**MMX34AA016_**||||||||||
|**MMX34AA023_**||||||||||
|**MMX32AA031_**<br>**MMX32AA038_**|6.50<br>(165.0)|5.51<br>(140.0)|14.57<br>(414.0)|13.82<br>(398.0)|15.08<br>(383.0)|8.07<br>(205.0)|0.28<br>(7.0)|0.55<br>(14.0)|FS5|
|**MMX34AA031_**<br>**MMX34AA038_**||||||||||
## _**Note**_
1 in = 25.4 mm, 1 mm = 0.0394 in
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-28**
Adjustable Frequency Drives
2.3
M-Max Series Drives
**2**
Approximate Dimensions in Inches (mm)
**NEMA 1/IP21 M-Max Drives and Communication Adapter Kit**
||||W2<br>W3|D||
|---|---|---|---|---|---|
|H||||||
|||||||
|||||||
||W1|||||
|**Frame Typ**|**e**<br>**H**|**W1**|**W2**<br>**W3**|**D**||
|**FS1**|8.14 (206.|7)<br>3.77 (95.7)<br>2.99 (75.9)<br>3.98 (101.2)||||
|**FS2**|9.90 (251.|5)<br>4.72 (120.0)<br>3.97 (100.8)<br>4.94 (125.5)||||
|**FS3**|12.26 (31|1.5)<br>5.12 (130.1)<br>4.36 (110.8)<br>5.33 (135.3)||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-29**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
**2**
## **DG1 General Purpose Drive**
## **Product Description**
The DG1 general purpose drives are part of Eaton’s next generation PowerXL Series of adjustable frequency drives specifically engineered for today’s more demanding commercial and industrial applications. The power unit makes use of the most sophisticated semiconductor technology and a highly modular construction that can be flexibly adapted to meet the customer’s needs.
The control module was designed to include today’s standard communication protocols and I/O while still having the modularity to add additional option cards.
Eaton’s patented Active Energy Control is also a standard feature on DG1 drives, offering customers increased efficiency, safety and reliability.
These drives continue the tradition of robust performance and raise the bar on features and functionality, ensuring the best solution at the right price.
## **Product Range**
## **Features and Benefits**
## **Hardware**
- Brake chopper standard on Frames 1, 2, 3
- Dual overload ratings
- 110% variable torque (IL)
- 150% constant torque (IH)
- Type 1/IP21 and Type 12/ IP54 enclosures available
- Integrated common mode reduction 5% DC link choke with input surge protection
- EMI/RFI filters standard on all drives—meets EMC Category C2
- Real-time clock—supports calendaring and PLC functionality
- Graphic LCD display and keypad—supports simple menu navigation as well as on-screen diagnostics and troubleshooting
- LOCAL/REMOTE operation from keypad and two configurable soft keys
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|PowerXL DG1 Series Drives||
|Standards and Certifications . . . . . . . . . . . . . .|**V6-T2-31**|
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V6-T2-31**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-32**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-34**|
|Replacement Parts . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-38**|
|Technical Data and Specifications . . . . . . . . . .|**V6-T2-40**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-44**|
## **Software**
- Active energy control— minimizes energy losses in your motor, resulting in industry-leading energy efficiency for your application
- Control logic can be powered from an external auxiliary control panel— internal drive functions and fieldbus if necessary
- Standard I/O:
- Quick Start Wizard upon initial power-up supports fast, easy installation
- 8DI, 1DO
- 2AI, 2AO
- Three relays
- Standard applications:
- Meets needs of most communication requirements
- Standard
- Multi-pump and fan Control
- Standard communications:
- Multi-PID
- EtherNet/IP, Modbus TCP
- Multi-purpose
- RS-485: Modbus RTU, BACnet MS/TP ● Copy/paste functionality
- ● Meets the needs of on drive keypad—allows most communication for fast setup of multiple drives
- Meets the needs of most communication requirements
- Pre-programmed I/O— supports fast, easy installation for most applications
- Seamless integration into EtherNet/IP networks via EIP-Assist I/O tag-generation tool
- Dynamic motor regenerative energy management
- Two expansion slots— intended to support additional I/O or communication protocols as necessary
- Advanced PC Tool with diagnostic capabilities
- Two configurable keypad soft keys
- Quick disconnect terminals for I/O connections— supports fast easy installation
- 230V to 125 hp, 310A, 90 kW
- 480V to 250 hp, 310A, 160 kW
- 575V to 250 hp, 250A, 160 kW
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-30**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
## **Standards and Certifications**
## **Product**
- IEC/EN 61800-5-1
- IEC/EN 61800-5-2
- UL 508C
- IEC 61508
- EN 62061
## **EMC**
- Immunity: IEC/EN 61800-3
- Category C2
## **Certification**
- UL
- cUL
- CE
- C-Tick
- RoHS
**2**
- EN ISO 13849-1
## **Catalog Number Selection**
**PowerXL Series—DG1 General Purpose Drive Series Power Part Options – – D G1 3 4 4D8 F B C 21 C Basic Naming Coating of Boards D** = Drive **C** = Coated **Series Phase Reference Internal Brake Chopper Enclosure (IP Rating) G1** = General purpose **3** = 3[~] INPUT/3[~] OUTPUT **N** = No brake chopper **21** = IP21/Type 1 **B** = Brake chopper **54** = IP54/Type 12 **Input/Output Voltage Rating 2** = 230V (208–240V, –15%, +10%) **4** = 400V (380–500V, –15%, +10%) **Internal EMC Filter Display Option 5** = 575V (525–600V, –15%, +10%) **F** = Internal EMC filter **C** = LCD (graphical) ~~===~~ **Output Current Rating (CT) 208–240V 380–500V 525–600V 3D7** = 3.7A, 0.55 kW, 0.75 hp **2D2** = 2.2A, 0.75 kW, 1 hp **3D3** = 3.3A, 1.5 kW, 2 hp **4D8** = 4.8A, 0.75 kW, 1 hp **3D3** = 3.3A, 1.1 kW, 1.5 hp **4D5** = 4.5A, 2.2 kW, 3 hp **6D6** = 6.6A, 1.1 kW, 1.5 hp **4D3** = 4.3A, 1.5 kW, 2 hp **7D5** = 7.5A, 3.7 kW, 5 hp **7D8** = 7.8A, 1.5 kW, 2 hp **5D6** = 5.6A, 2.2 kW, 3 hp **010** = 10A, 5.5 kW, 7.5 hp **011** = 11A, 2.2 kW, 3 hp **7D6** = 7.6A, 3 kW, 5 hp **013** = 13.5A, 7.5 kW, 10 hp **012** = 12.5A, 3 kW, 5 hp (VT) **9D0** = 9A, 4 kW, 7.5 hp (VT) **018** = 18A, 11 kW, 15 hp **017** = 17.5A, 3.7 kW, 5 hp **012** = 12A, 5.5 kW, 7.5 hp **022** = 22A, 15 kW, 20 hp **025** = 25A, 5.5 kW, 7.5 hp **016** = 16A, 7.5 kW, 10 hp **027** = 27A, 18 kW, 25 hp **031** = 31A, 7.5 kW, 10 hp **023** = 23A, 11 kW, 15 hp **034** = 34A, 22 kW, 30 hp **048** = 48A, 11 kW, 15 hp **031** = 31A, 15 kW, 20 hp **041** = 41A, 30 kW, 40 hp **061** = 61A, 15 kW, 20 hp **038** = 38A, 18 kW, 25 hp **052** = 52A, 37 kW, 50 hp **075** = 75A, 18.5 kW, 25 hp **046** = 46A, 22 kW, 30 hp **062** = 62A, 45 kW, 60 hp **088** = 88A, 22 kW, 30 hp **061** = 61A, 30 kW, 40 hp **080** = 80A, 55 kW, 75 hp **114** = 114A, 30 kW, 40 hp **072** = 72A, 37 kW, 50 hp **100** = 100A, 75 kW, 100 hp **143** = 143A, 37 kW, 50 hp **087** = 87A, 45 kW, 60 hp **125** = 125A, 90 kW, 125 hp **170** = 170A, 45 kW, 60 hp **105** = 105A, 55 kW, 75 hp **144** = 144A, 110 kW, 150 hp **211** = 211A, 55 kW, 75 hp **140** = 140A, 75 kW, 100 hp **208** = 208A, 160 kW, 200 hp **261** = 261A, 75 kW, 100 hp **170** = 170A, 90 kW, 125 hp **205** = 205A, 110 kW, 150 hp **261** = 261A, 132 kW, 200 hp
**PowerXL Series—DG1 General Purpose Drive Option Boards**
**– – DX G NET PROFB Basic Naming Series Type Function DX** = PowerXL Drive **G** = General purpose **NET** = Communication card **PROFIBUS** = PROFIBUS **EXT** = I/O card **DEVICENET** = DeviceNet **ACC** = Accessory **LONWORKS** = LonWorks **SPR** = Spare part **CANOPEN** = CANopen **KEY** = Keypad **SWD** = SmartWire **CBL** = Cable See Accessories on **Page V6-T2-34** ~~=~~ for full offering
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014
**V6-T2-31**
www.eaton.com
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
## **Product Selection**
**2**
## **DG1 Series Drives—208–240 Volt**
|**PowerXL Series—DG1**<br>bs~~a~~|**Type 1/IP21**<br>**Frame Size**<br>FR1<br>FR2<br>~~a~~|**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>**Current**<br>**A (VT/IL)**<br>**Catalog Number**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>4.8<br>**DG1-323D7FB-C21C**<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>6.6<br>**DG1-324D8FB-C21C**<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>7.8<br>**DG1-326D6FB-C21C**<br>1.5<br>2.2<br>2<br>3<br>7.8<br>11<br>**DG1-327D8FB-C21C**<br>2.2<br>3<br>3<br>—<br>11<br>12.5<br>**DG1-32011FB-C21C**<br>3<br>3.7<br>—<br>5<br>12.5<br>17.5<br>**DG1-32012FB-C21C**<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>25<br>**DG1-32017FB-C21C**<br>5.5<br>7.5<br>7.5<br>10<br>25<br>31<br>**DG1-32025FB-C21C**<br>~~a~~|**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>**Current**<br>**A (VT/IL)**<br>**Catalog Number**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>4.8<br>**DG1-323D7FB-C21C**<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>6.6<br>**DG1-324D8FB-C21C**<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>7.8<br>**DG1-326D6FB-C21C**<br>1.5<br>2.2<br>2<br>3<br>7.8<br>11<br>**DG1-327D8FB-C21C**<br>2.2<br>3<br>3<br>—<br>11<br>12.5<br>**DG1-32011FB-C21C**<br>3<br>3.7<br>—<br>5<br>12.5<br>17.5<br>**DG1-32012FB-C21C**<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>25<br>**DG1-32017FB-C21C**<br>5.5<br>7.5<br>7.5<br>10<br>25<br>31<br>**DG1-32025FB-C21C**<br>~~a~~|**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>**Current**<br>**A (VT/IL)**<br>**Catalog Number**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>4.8<br>**DG1-323D7FB-C21C**<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>6.6<br>**DG1-324D8FB-C21C**<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>7.8<br>**DG1-326D6FB-C21C**<br>1.5<br>2.2<br>2<br>3<br>7.8<br>11<br>**DG1-327D8FB-C21C**<br>2.2<br>3<br>3<br>—<br>11<br>12.5<br>**DG1-32011FB-C21C**<br>3<br>3.7<br>—<br>5<br>12.5<br>17.5<br>**DG1-32012FB-C21C**<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>25<br>**DG1-32017FB-C21C**<br>5.5<br>7.5<br>7.5<br>10<br>25<br>31<br>**DG1-32025FB-C21C**<br>~~a~~|**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>**Current**<br>**A (VT/IL)**<br>**Catalog Number**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>4.8<br>**DG1-323D7FB-C21C**<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>6.6<br>**DG1-324D8FB-C21C**<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>7.8<br>**DG1-326D6FB-C21C**<br>1.5<br>2.2<br>2<br>3<br>7.8<br>11<br>**DG1-327D8FB-C21C**<br>2.2<br>3<br>3<br>—<br>11<br>12.5<br>**DG1-32011FB-C21C**<br>3<br>3.7<br>—<br>5<br>12.5<br>17.5<br>**DG1-32012FB-C21C**<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>25<br>**DG1-32017FB-C21C**<br>5.5<br>7.5<br>7.5<br>10<br>25<br>31<br>**DG1-32025FB-C21C**<br>~~a~~|**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>**Current**<br>**A (VT/IL)**<br>**Catalog Number**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>4.8<br>**DG1-323D7FB-C21C**<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>6.6<br>**DG1-324D8FB-C21C**<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>7.8<br>**DG1-326D6FB-C21C**<br>1.5<br>2.2<br>2<br>3<br>7.8<br>11<br>**DG1-327D8FB-C21C**<br>2.2<br>3<br>3<br>—<br>11<br>12.5<br>**DG1-32011FB-C21C**<br>3<br>3.7<br>—<br>5<br>12.5<br>17.5<br>**DG1-32012FB-C21C**<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>25<br>**DG1-32017FB-C21C**<br>5.5<br>7.5<br>7.5<br>10<br>25<br>31<br>**DG1-32025FB-C21C**<br>~~a~~|**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>**Current**<br>**A (VT/IL)**<br>**Catalog Number**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>4.8<br>**DG1-323D7FB-C21C**<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>6.6<br>**DG1-324D8FB-C21C**<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>7.8<br>**DG1-326D6FB-C21C**<br>1.5<br>2.2<br>2<br>3<br>7.8<br>11<br>**DG1-327D8FB-C21C**<br>2.2<br>3<br>3<br>—<br>11<br>12.5<br>**DG1-32011FB-C21C**<br>3<br>3.7<br>—<br>5<br>12.5<br>17.5<br>**DG1-32012FB-C21C**<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>25<br>**DG1-32017FB-C21C**<br>5.5<br>7.5<br>7.5<br>10<br>25<br>31<br>**DG1-32025FB-C21C**<br>~~a~~|**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>**Current**<br>**A (VT/IL)**<br>**Catalog Number**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>4.8<br>**DG1-323D7FB-C21C**<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>6.6<br>**DG1-324D8FB-C21C**<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>7.8<br>**DG1-326D6FB-C21C**<br>1.5<br>2.2<br>2<br>3<br>7.8<br>11<br>**DG1-327D8FB-C21C**<br>2.2<br>3<br>3<br>—<br>11<br>12.5<br>**DG1-32011FB-C21C**<br>3<br>3.7<br>—<br>5<br>12.5<br>17.5<br>**DG1-32012FB-C21C**<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>25<br>**DG1-32017FB-C21C**<br>5.5<br>7.5<br>7.5<br>10<br>25<br>31<br>**DG1-32025FB-C21C**<br>~~a~~|
|---|---|---|---|---|---|---|---|---|
||FR3|7.5|11|10|15|31|48|**DG1-32031FB-C21C**|
|||11|15|15|20|48|61|**DG1-32048FB-C21C**|
||FR4|15|18.5|20|25|61|75|**DG1-32061FN-C21C**|
|||18.5<br>22|22<br>30|25<br>30|30<br>40|75<br>88|88<br>114|**DG1-32075FN-C21C**<br>**DG1-32088FN-C21C**|
||FR5|30|37|40|50|114|143|**DG1-32114FN-C21C**|
|||37|45|50|60|143|170|**DG1-32143FN-C21C**|
|||45|55|60|75|170|211|**DG1-32170FN-C21C**|
||FR61|55|75|75|100|211|261|**DG1-32211FN-C21C**|
|||75|90|100|125|261|312|**DG1-32261FN-C21C**|
## **Type 12/IP54**
|**PowerXL Series—DG1**<br>bs|**Type 12/IP54**<br>**Frame Size**<br>FR1<br>FR2<br>FR3<br>|**Type 12/IP54**<br>**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>1.5<br>2.2<br>2<br>3<br>7.8<br>2.2<br>3<br>3<br>—<br>11<br>3<br>3.7<br>—<br>5<br>12.5<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>5.5<br>7.5<br>7.5<br>10<br>25<br>7.5<br>11<br>10<br>15<br>31<br> ~~Oe~~|**Type 12/IP54**<br>**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>1.5<br>2.2<br>2<br>3<br>7.8<br>2.2<br>3<br>3<br>—<br>11<br>3<br>3.7<br>—<br>5<br>12.5<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>5.5<br>7.5<br>7.5<br>10<br>25<br>7.5<br>11<br>10<br>15<br>31<br> ~~Oe~~|**Type 12/IP54**<br>**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>1.5<br>2.2<br>2<br>3<br>7.8<br>2.2<br>3<br>3<br>—<br>11<br>3<br>3.7<br>—<br>5<br>12.5<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>5.5<br>7.5<br>7.5<br>10<br>25<br>7.5<br>11<br>10<br>15<br>31<br> ~~Oe~~|**Type 12/IP54**<br>**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>1.5<br>2.2<br>2<br>3<br>7.8<br>2.2<br>3<br>3<br>—<br>11<br>3<br>3.7<br>—<br>5<br>12.5<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>5.5<br>7.5<br>7.5<br>10<br>25<br>7.5<br>11<br>10<br>15<br>31<br> ~~Oe~~|**Type 12/IP54**<br>**230V, 50 Hz**<br>**kW Rating (CT/IH)**<br>**230V, 50 Hz**<br>**kW Rating (VT/IL)**<br>**230V, 60 Hz**<br>**hp (CT/IH)**<br>**230V, 60 Hz**<br>**hp (VT/IL)**<br>**Current**<br>**A (CT/IH)**<br>0.55<br>0.75<br>0.75<br>1<br>3.7<br>0.75<br>1.1<br>1<br>1.5<br>4.8<br>1.1<br>1.5<br>1.5<br>2<br>6.6<br>1.5<br>2.2<br>2<br>3<br>7.8<br>2.2<br>3<br>3<br>—<br>11<br>3<br>3.7<br>—<br>5<br>12.5<br>3.7<br>5.5<br>5<br>7.5<br>17.5<br>5.5<br>7.5<br>7.5<br>10<br>25<br>7.5<br>11<br>10<br>15<br>31<br> ~~Oe~~|**Current**<br>**A (VT/IL)**<br>4.8<br>6.6<br>7.8<br>11<br>12.5<br>17.5<br>25<br>31<br>48|**Catalog Number**<br>**DG1-323D7FB-C54C**<br>**DG1-324D8FB-C54C**<br>**DG1-326D6FB-C54C**<br>**DG1-327D8FB-C54C**<br>**DG1-32011FB-C54C**<br>**DG1-32012FB-C54C**<br>**DG1-32017FB-C54C**<br>**DG1-32025FB-C54C**<br>**DG1-32031FB-C54C**|
|---|---|---|---|---|---|---|---|---|
|||11|15|15|20|48|61|**DG1-32048FB-C54C**|
||FR4|15|18.5|20|25|61|75|**DG1-32061FN-C54C**|
|||18.5|22|25|30|75|88|**DG1-32075FN-C54C**|
|||22|30|30|40|88|114|**DG1-32088FN-C54C**|
||FR5|30<br>37|37<br>45|40<br>50|50<br>60|114<br>143|143<br>170|**DG1-32114FN-C54C**<br>**DG1-32143FN-C54C**|
|||45|55|60|75|170|211|**DG1-32170FN-C54C**|
||FR61|55|75|75|100|211|261|**DG1-32211FN-C54C**|
|||75|90|100|125|261|312|**DG1-32261FN-C54C**|
## _**Note**_
1 FR6 available in 2015.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-32**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
## **DG1 Series Drives—380–500 Volt**
**PowerXL Series—DG1 Type 1/IP21**
|**PowerXL Series—DG1**|**Type 1/IP21**|**Type 1/IP21**|||||||
|---|---|---|---|---|---|---|---|---|
|||**400V, 50 Hz**|**400V, 50 Hz**|**460V, 60 Hz**|**460V, 60 Hz**|**Current**|**Current**||
||**Frame Size**<br>FR1|**kW Rating (CT/IH)**<br>0.75|**kW Rating (VT/IL)**<br>1.1|**hp (CT/IH)**<br>1|**hp (VT/IL)**<br>1.5|**A (CT/IH)**<br>2.2|**A (VT/IL)**<br>3.3|**Catalog Number**<br>**DG1-342D2FB-C21C**|
|coe||1.1<br>1.5<br>1.5<br>2<br>3.3<br>4.3<br>**DG1-343D3FB-C21C**<br>1.5<br>2.2<br>2<br>3<br>4.3<br>5.6<br>**DG1-344D3FB-C21C**<br>2.2<br>3<br>3<br>5<br>5.6<br>7.6<br>**DG1-345D6FB-C21C**<br> ~~OO~~|||||||
|||3|4|5|—|7.6|9|**DG1-347D6FB-C21C**|
|||4|5.5|—|7.5|9|12|**DG1-349D0FB-C21C**|
||FR2|5.5<br>7.5|7.5<br>11|7.5<br>10|10<br>15|12<br>16|16<br>23|**DG1-34012FB-C21C**<br>**DG1-34016FB-C21C**|
|||11|15|15|20|23|31|**DG1-34023FB-C21C**|
||FR3|15|18.5|20|25|31|38|**DG1-34031FB-C21C**|
|||18.5|22|25|30|38|46|**DG1-34038FB-C21C**|
|||22|30|30|40|46|61|**DG1-34046FB-C21C**|
||FR4|30|37|40|50|61|72|**DG1-34061FN-C21C**|
|||37<br>45|45<br>55|50<br>60|60<br>75|72<br>87|87<br>105|**DG1-34072FN-C21C**<br>**DG1-34087FN-C21C**|
||FR5|55|75|75|100|105|140|**DG1-34105FN-C21C**|
|||75|90|100|125|140|170|**DG1-34140FN-C21C**|
|||90|110|125|150|170|205|**DG1-34170FN-C21C**|
||FR61|110|132|150|200|205|261|**DG1-34205FN-C21C**|
|||132|160|200|250|261|310|**DG1-34261FN-C21C**|
|**PowerXL Series—DG1**|**Type 12/IP54**<br>**400V, 50 Hz**||**400V, 50 Hz**|**460V, 60 Hz**|**460V, 60 Hz**|**Current**|**Current**||
|=|**Frame Size**<br>FR1<br>|**kW Rating (CT/IH)**<br>**kW Rating (VT/IL)**<br>**hp (CT/IH)**<br>**hp (VT/IL)**<br>0.75<br>1.1<br>1<br>1.5<br>1.1<br>1.5<br>1.5<br>2<br>1.5<br>2.2<br>2<br>3<br>2.2<br>3<br>3<br>5<br> ~~OO~~||||**A (CT/IH)**<br>2.2<br>3.3<br>4.3<br>5.6|**A (VT/IL)**<br>3.3<br>4.3<br>5.6<br>7.6|**Catalog Number**<br>**DG1-342D2FB-C54C**<br>**DG1-343D3FB-C54C**<br>**DG1-344D3FB-C54C**<br>**DG1-345D6FB-C54C**|
|||3|4|5|—|7.6|9|**DG1-347D6FB-C54C**|
|||4|5.5|—|7.5|9|12|**DG1-349D0FB-C54C**|
||FR2|5.5<br>7.5|7.5<br>11|7.5<br>10|10<br>15|12<br>16|16<br>23|**DG1-34012FB-C54C**<br>**DG1-34016FB-C54C**|
|||11|15|15|20|23|31|**DG1-34023FB-C54C**|
||FR3|15|18.5|20|25|31|38|**DG1-34031FB-C54C**|
|||18.5|22|25|30|38|46|**DG1-34038FB-C54C**|
||FR4|22<br>30|30<br>37|30<br>40|40<br>50|46<br>61|61<br>72|**DG1-34046FB-C54C**<br>**DG1-34061FN-C54C**|
|||37|45|50|60|72|87|**DG1-34072FN-C54C**|
|||45|55|60|75|87|105|**DG1-34087FN-C54C**|
||FR5|55|75|75|100|105|140|**DG1-34105FN-C54C**|
|||75|90|100|125|140|170|**DG1-34140FN-C54C**|
|||90|110|125|150|170|205|**DG1-34170FN-C54C**|
||FR61|110<br>132|132<br>160|150<br>200|200<br>250|205<br>261|261<br>310|**DG1-34205FN-C54C**<br>**DG1-34261FN-C54C**|
**PowerXL Series—DG1 Type 12/IP54**
**2**
## _**Note**_
1 FR6 available in 2015.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-33**
## 2.4
## Adjustable Frequency Drives
## PowerXL DG1 Series Drives
## **Accessories**
The PowerXL Series—DG1 drives can accommodate a wide **2** selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is **2** designed to accept a total of two additional option boards.
The PowerXL Series—DG1 drives come with a factory-installed standard board configuration including the following:
- Standard I/O:
- 8DI, 1DO
- 2AI, 2AO
- Three relays
## **PowerXL Series—DG1 Conversion and Flange Kits**
The Type 12/IP54 option kit is used to convert a Type 1/IP21 to a Type 12/IP54 drive. The kit includes cover, fan and grommets.
## **Type 12/IP54 Conversion Kits**
|**Type 12/IP54 Conversion Kits**||
|---|---|
|**Description**|**Catalog Number**|
|Frame 1 230V Type 12/IP54 kit|**DXG-ACC-2FR1N12KIT**|
|Frame 1 480V Type 12/IP54 kit|**DXG-ACC-4FR1N12KIT**|
|Frame 2 Type 12/IP54 kit|**DXG-ACC-FR2N12KIT**|
|Frame 3 Type 12/IP54 kit|**DXG-ACC-FR3N12KIT**|
- Standard communications:
- EtherNet/IP, Modbus TCP
- RS-485: Modbus RTU, BACnet MS/TP
## **PowerXL Series—DG1 I/O Card Kits**
|**PowerXL Series—DG1 I/O Card Kits**||
|---|---|
|**Description**|**Catalog Number**|
|3 x DI, 3 x DO, 1 x thermistor, 24 Vdc/EXT option card|**DXG-EXT-3DI3DO1T**|
|1 x AI, 2 x AO (isolated to control board) option card|**DXG-EXT-1AI2AO**|
|3 x relay dry contact (2NO + 1NO/NC) option card|**DXG-EXT-3RO**|
|3 x PT100 RTD thermistor input option card<br>6 x DI 240 Vac input option card|**DXG-EXT-THER1**<br>**DXG-EXT-6DI**|
The flange kit is used when the power section heat sink is mounted through the back panel of an enclosure. The kit includes hardware, top flange plate, bottom flange plate and two side flange plates.
## **Flange Kits**
|**Flange Kits**||
|---|---|
|**Description**|**Catalog Number**|
|Frame 1 flange kit Type 12/IP54|**DXG-ACC-FR1N12FK**|
|Frame 2 flange kit Type 12/IP54|**DXG-ACC-FR2N12FK**|
|Frame 3 flange kit Type 12/IP54|**DXG-ACC-FR3N12FK**|
|Frame 4 flange kit Type 12/IP54|**DXG-ACC-FR4N12FK**|
|Frame 5 flange kit Type 12/IP54|**DXG-ACC-FR5N12FK**|
## **PowerXL Series—DG1 Communication Card Kits**
|**Description**|**Catalog Number**|
|---|---|
|PROFIBUS-DP communication card|**DXG-NET-PROFIBUS**|
|CANopen communication card|**DXG-NET-CANOPEN**|
|DeviceNet communication card|**DXG-NET-DEVICENET**|
|PROFIBUS DB9 to 5-pin adapter card<br>SmartWire communication card and module|**DXG-MNT-PROFIBUS**<br>**DXG-NET-SWD**|
|LonWorks communication card|**DXG-NET-LONWORKS**|
## **PowerXL Series—DG1 Demo Units**
## **Demo Units**
|**Demo Units**||
|---|---|
|**Description**|**Catalog Number**|
|DG1 control module demo stand|**DG1-DEMO1**|
|DG1 full drive demo case|**DG1-DEMO2**|
## **PowerXL Series—DG1 Keypad Kits**
|**PowerXL Series—DG1 Keypad Kits**||
|---|---|
|**Description**|**Catalog Number**|
|Standard keypad|**DXG-KEY-LCD**|
|Remote keypad kit (0.5m cable)|**DXG-KEY-RMTKIT**|
|1m remote keypad cable<br>3m remote keypad cable|**DXG-CBL-1M0**<br>**DXG-CBL-3M0**|
|Remote keypad mounting holder only|**DXG-KEY-HOLDER**|
|Type 12/IP54 keypad hole plug (maintain rating without keypad)|**DXG-KEY-N12PLUG**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-34**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
## **PowerXpert** _**in**_ **Control Software**
The PowerXL Series PC Tool is designed for programming, controlling and monitoring of the DG1 drives. Features include loading parameters that can be saved to a file or printed, setting references, starting and stopping the motor, monitoring signals in graphical or text form, and real-time display.
**2**
## **PowerXpert** _**in**_ **Control Software**
**Description Catalog Number** ~~SSS~~ Software kit (software, cable, manual) **DXG-ACC-SOFTWARE** Software cable (USB to RJ45 [RS-485]) **DXG-CBL-PCCABLE** Real-time clock battery **DXG-ACC-RTBATT**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-35**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
## **Brake Chopper Options**
The brake chopper circuit option is used for applications **2** that require dynamic braking. Dynamic braking resistors are **2** not included with drive purchase. Consult the factory **2** for additional dynamic braking resistor selections that are **2** supplied separately. A list of common resistors are listed below and are complete **2** indoor assemblies, include a pre-wired terminal block and **2** a thermal switch, and are not UL Listed.
## _**Duty Cycle**_
The duty cycle rating is based on a 60-second period. For example, the 20% duty cycle resistor can carry 100% current for 12 seconds out of every 60 seconds, while the 50% duty cycle resistor can carry 150% current for 30 seconds out of every 60 seconds.
## _**Torque**_
If the braking torque required is less than 15%, dynamic braking is not required because the regenerated energy will be dissipated in the drive and motor losses.
## **Dynamic Brake Resistor—Catalog Number Selection**
## **– – DBR R100 W0800**
**==> picture [266 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
Dynamic Brake Resistor Resistance Rated Watts<br>1D0 = 1.0 Ohms 0800 = 800 Watts<br>100 = 100 Ohms 8000 = 8000 Watts<br>080K = 80,000 Watts<br>**----- End of picture text -----**<br>
## **230V Brake Resistors**
|**Drive hp**|**Minimum**|**20% Duty Cycle, 100%**|**Torque**|**50% Duty Cycle, 150%**|**Torque**|
|---|---|---|---|---|---|
|**(CT/IH)**|**Ohms**|**Catalog Number**|**Dimensions**|**Catalog Number**|**Dimensions**|
|0.75|15.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W0800**|12W x 7D x 5H|
|1|15.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W0800**|12W x 7D x 5H|
|1.5|15.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R036-W1200**|12W x 10D x 5H|
|2|15.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R036-W1200**|12W x 10D x 5H|
|3|15.0|**DBR-R036-W0800**|12W x 7D x 5H|**DBR-R036-W2000**|12W x 16D x 5H|
|4|9.0|**DBR-R036-W0800**|12W x 7D x 5H|**DBR-R012-W2400**|19W x 10D x 5H|
|5|9.0|**DBR-R036-W0800**|12W x 7D x 5H|**DBR-R020-W2800**|19W x 13D x 5H|
|7.5|9.0|**DBR-R020-W1200**|12W x 10D x 5H|**DBR-R012-W4800**|26.5W x 10D x 5H|
|10|7.0|**DBR-R015-W1600**|12W x 13D x 5H|**DBR-R112-W6000**|26.5W x 13D x 5H|
|15<br>20|7.0<br>2.0|**DBR-R012-W2400**<br>**DBR-R9D3-W3200**|19W x 10D x 5H<br>19W x 10D x 5H|**DBR-R7D8-W9000**<br>**DBR-R3D4-W012K**|28W x 10D x 10H<br>28W x 10D x 10H|
|25|2.0|**DBR-R5D5-W4000**|26.5W x 10D x 5H|**DBR-R5D1-W015K**|28W x 16D x 10H|
|30|2.0|**DBR-R4D8-W4800**|26.5W x 10D x 5H|**DBR-R4D1-W020K**|28W x 16D x 10H|
|40|2.0|**DBR-R004-W6000**|26.5W x 13D x 5H|**DBR-R3D4-W025K**|30W x 18D x 16H|
|50|2.0|**DBR-R3D1-W7500**|26.5W x 16D x 5H|**DBR-R2D1-W030K**|30W x 18D x 24H|
|60|2.0|**DBR-R2D8-W9000**|26.5W x 16D x 5H|**DBR-R002-W036K**|30W x 18D x 24H|
|75<br>100|2.0<br>2.0|**DBR-R2D6-W012K**<br>**DBR-R002-W015K**|28W x 10D x 10H<br>28W x 16D x 10H|**DBR-R002-W045K**<br>**DBR-R002-W060K**|30W x 18D x 32H<br>30W x 18D x 48H|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-36**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
**480V Brake Resistors**
|**Drive hp**|**Minimum**|**20% Duty Cycle, 100%**|**Torque**|**50% Duty Cycle, 150%**|**Torque**|
|---|---|---|---|---|---|
|**(CT/IH)**|**Ohms**|**Catalog Number**|**Dimensions**|**Catalog Number**|**Dimensions**|
|1|36.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W0800**|12W x 7D x 5H|
|1.5|36.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W1200**|12W x 10D x 5H|
|2|36.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W1200**|12W x 10D x 5H|
|3|36.0|**DBR-R100-W0800**|12W x 7D x 5H|**DBR-R100-W2000**|12W x 16D x 5H|
|5|36.0|**DBR-R100-W0800**|12W x 7D x 5H|**DBR-R100-W2800**|19W x 13D x 5H|
|6|36.0|**DBR-R100-W1200**|12W x 10D x 5H|**DBR-R070-W4000**|19W x 16D x 5H|
|7.5|18.0|**DBR-R100-W1200**|12W x 10D x 5H|**DBR-R020-W4800**|26.5W x 13D x 5H|
|10|18.0|**DBR-R063-W1600**|12W x 13D x 5H|**DBR-R030-W6000**|26.5W x 16D x 5H|
|15|18.0|**DBR-R030-W2400**|19W x 10D x 5H|**DBR-R030-W9000**|28W x 10D x 10H|
|20|13.0|**DBR-R030-W3200**|19W x 13D x 5H|**DBR-R023-W012K**|28W x 13D x 10H|
|25|13.0|**DBR-R030-W4000**|19W x 16D x 5H|**DBR-R013-W015K**|28W x 16D x 10H|
|30|13.0|**DBR-R020-W4800**|26.5W x 13D x 5H|**DBR-R014-W020K**|30W x 18D x 24H|
|40|2.0|**DBR-R112-W6000**|26.5W x 13D x 5H|**DBR-R007-W025K**|30W x 18D x 16H|
|50|2.0|**DBR-R013-W7500**|26.5W x 16D x 5H|**DBR-R8D5-W030K**|30W x 18D x 24H|
|60|2.0|**DBR-R010-W9000**|28W x 10D x 10H|**DBR-R7D3-W036K**|30W x 18D x 24H|
|75|2.0|**DBR-R009-W012K**|28W x 13D x 10H|**DBR-R002-W045K**|30W x 18D x 32H|
|100|2.0|**DBR-R5D1-W015K**|28W x 16D x 10H|**DBR-R004-W060K**|30W x 18D x 40H|
|125|2.0|**DBR-R4D1-W020K**|28W x 16D x 10H|**DBR-R004-W070K**|30W x 18D x 48H|
|150|2.0|**DBR-R3D4-W025K**|30W x 18D x 16H|**DBR-R3D5-W085K**|30W x 18D x 56H|
|200|2.0|**DBR-R3D3-W030K**|30W x 18D x 24H|**DBR-R2D6-W110K**|30W x 18D x 64H|
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-37**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
**2**
## **Replacement Parts**
## **Frame 1**
|**Frame 1**||||
|---|---|---|---|
||**Catalog Number**|**Catalog Number**|**Catalog Number**|
|**Description**<br>Standard keypad1|**230V**<br>**DXG-KEY-LCD**|**480V**<br>**DXG-KEY-LCD**|**575V**<br>**DXG-KEY-LCD**|
|Main control board1<br>Control board cover|**DXG-SPR-CTRLBOARD**<br>**DXG-SPR-BCOVER**|**DXG-SPR-CTRLBOARD**<br>**DXG-SPR-BCOVER**|**DXG-SPR-CTRLBOARD**<br>**DXG-SPR-BCOVER**|
|Type 1/IP21 standard cover|**DXG-SPR-FR1CVR**|**DXG-SPR-FR1CVR**|2|
|Main fan kit1|**DXG-SPR-FR1FAN**|**DXG-SPR-FR1FAN**|2|
|Control fan|**DXG-SPR-2FR1CF**|**DXG-SPR-4FR1CF**|2|
|Main power board|**DXG-SPR-2FR1MPB**|**DXG-SPR-4FR1MPB**|2|
|EMI board|**DXG-SPR-2FR1EB**|**DXG-SPR-4FR1EB**|2|
|Middle chassis cover|**DXG-SPR-FR1MCC**|**DXG-SPR-FR1MCC**|2|
|Outer housing|**DXG-SPR-FR1OH**|**DXG-SPR-FR1OH**|2|
|UL conduit plate<br>IEC conduit plate|**DXG-SPR-FR1CPUL**<br>**DXG-SPR-FR1CPIEC**|**DXG-SPR-FR1CPUL**<br>**DXG-SPR-FR1CPIEC**|2<br>2|
|**Frame 2**||||
|**Description**|**Catalog Number**<br>**230V**|**Catalog Number**<br>**480V**|**Catalog Number**<br>**575V**|
|Standard keypad1<br>Main control board1|**DXG-KEY-LCD**<br>**DXG-SPR-CTRLBOARD**|**DXG-KEY-LCD**<br>**DXG-SPR-CTRLBOARD**|**DXG-KEY-LCD**<br>**DXG-SPR-CTRLBOARD**|
|Control board cover<br>Type 1/IP21 standard cover|**DXG-SPR-BCOVER**<br>**DXG-SPR-FR2CVR**|**DXG-SPR-BCOVER**<br>**DXG-SPR-FR2CVR**|**DXG-SPR-BCOVER**<br>2|
|Main fan kit1<br>Control fan|**DXG-SPR-FR2FAN**<br>**DXG-SPR-FR2CF**|**DXG-SPR-FR2FAN**<br>**DXG-SPR-FR2CF**|2<br>2|
|Bus capacitor|**DXG-SPR-2FR2BC**|**DXG-SPR-4FR24BC**|2|
|Main power board|**DXG-SPR-2FR2MPB**|**DXG-SPR-4FR2MPB**|2|
|EMI board|**DXG-SPR-2FR2EB**|**DXG-SPR-4FR2EB**|2|
|IGBT module|**DXG-SPR-FR2IGBT**|**DXG-SPR-FR2IGBT**|2|
|Middle chassis cover|**DXG-SPR-FR2MCC**|**DXG-SPR-FR2MCC**|2|
|Outer housing|**DXG-SPR-FR2OH**|**DXG-SPR-FR2OH**|2|
|UL conduit plate|**DXG-SPR-FR2CPUL**|**DXG-SPR-FR2CPUL**|2|
|IEC conduit plate|**DXG-SPR-FR2CPIEC**|**DXG-SPR-FR2CPIEC**|2|
|**Frame 3**||||
||**Catalog Number**|**Catalog Number**|**Catalog Number**|
|**Description**|**230V**|**480V**|**575V**|
|Standard keypad1|**DXG-KEY-LCD**|**DXG-KEY-LCD**|**DXG-KEY-LCD**|
|Main control board1|**DXG-SPR-CTRLBOARD**|**DXG-SPR-CTRLBOARD**|**DXG-SPR-CTRLBOARD**|
|Control board cover|**DXG-SPR-BCOVER**|**DXG-SPR-BCOVER**|**DXG-SPR-BCOVER**|
|Type 1/IP21 standard cover<br>Main fan kit1|**DXG-SPR-FR3CVR**<br>**DXG-SPR-FR3FAN**|**DXG-SPR-FR3CVR**<br>**DXG-SPR-FR3FAN**|2<br>2|
|Control fan<br>Bus capacitor|**DXG-SPR-FR34CF**<br>**DXG-SPR-FR3BC**|**DXG-SPR-FR34CF**<br>**DXG-SPR-FR3BC**|2<br>2|
|Main power board|**DXG-SPR-2FR3MPB**|**DXG-SPR-4FR3MPB**|2|
|EMI board|**DXG-SPR-2FR3EB**|**DXG-SPR-4FR3EB**|2|
|Drive board|**DXG-SPR-2FR3DB**|**DXG-SPR-4FR3DB**|2|
|Output board|**DXG-SPR-FR3OB**|**DXG-SPR-FR3OB**|2|
|Middle chassis cover|**DXG-SPR-FR3MCC**|**DXG-SPR-FR3MCC**|2|
|Outer housing|**DXG-SPR-FR3OH**|**DXG-SPR-FR3OH**|2|
|UL conduit plate|**DXG-SPR-FR3CPUL**|**DXG-SPR-FR3CPUL**|2|
|IEC conduit plate|**DXG-SPR-FR3CPIEC**|**DXG-SPR-FR3CPIEC**|2|
## _**Notes**_
> 1 Factory recommended spare parts.
> 2 575V available in 2015.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-38**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
## **Frame 4**
|**Frame 4**||||
|---|---|---|---|
||**230V**|**480V**|**575V**|
|**Description**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|Standard keypad1|**DXG-KEY-LCD**|**DXG-KEY-LCD**|**DXG-KEY-LCD**|
|Main control board1|**DXG-SPR-CTRLBOARD**|**DXG-SPR-CTRLBOARD**|**DXG-SPR-CTRLBOARD**|
|Control board cover|**DXG-SPR-BCOVER**|**DXG-SPR-BCOVER**|**DXG-SPR-BCOVER**|
|Type 1/IP21 standard cover|**DXG-SPR-FR4CVR**|**DXG-SPR-FR4CVR**|2|
|Main fan kit1|**DXG-SPR-FR4FAN**|**DXG-SPR-FR4FAN**|2|
|Control fan|**DXG-SPR-FR34CF**|**DXG-SPR-FR34CF**|2|
|Bus capacitor|**DXG-SPR-2FR4BC**|**DXG-SPR-4FR24BC**|2|
|Main power board|**DXG-SPR-2FR4MPB**|**DXG-SPR-4FR4MPB**|2|
|EMI board|**DXG-SPR-2FR4EB**|**DXG-SPR-4FR4EB**|2|
|Softstart board|**DXG-SPR-2FR4SB**|**DXG-SPR-4FR4SB**|2|
|IGBT module|**DXG-SPR-2FR4IGBT**|**DXG-SPR-4FR4IGBT**|2|
|Rectifier module|**DXG-SPR-2FR4RM**|**DXG-SPR-4FR4RM**|2|
|Brake chopper module|**DXG-SPR-2FR4BCM**|**DXG-SPR-4FR4BCM**|2|
|Middle chassis cover|**DXG-SPR-FR4MCC**|**DXG-SPR-FR4MCC**|2|
|Outer housing|**DXG-SPR-FR4OH**|**DXG-SPR-FR4OH**|2|
|UL conduit plate|**DXG-SPR-FR4CPUL**|**DXG-SPR-FR4CPUL**|2|
|IEC conduit plate|**DXG-SPR-FR4CPIEC**|**DXG-SPR-FR4CPIEC**|2|
**2**
## **Frame 5**
|**Frame 5**||||
|---|---|---|---|
||**230V**|**480V**|**575V**|
|**Description**|**Catalog Number**|**Catalog Number**|**Catalog Number**|
|Standard keypad1|**DXG-KEY-LCD**|**DXG-KEY-LCD**|**DXG-KEY-LCD**|
|Main control board1|**DXG-SPR-CTRLBOARD**|**DXG-SPR-CTRLBOARD**|**DXG-SPR-CTRLBOARD**|
|Control board cover|**DXG-SPR-BCOVER**|**DXG-SPR-BCOVER**|**DXG-SPR-BCOVER**|
|Type 1/IP21 standard cover|**DXG-SPR-FR5CVR**|**DXG-SPR-FR5CVR**|2|
|Main fan kit1|**DXG-SPR-FR5FAN**|**DXG-SPR-FR5FAN**|2|
|Control fan|**DXG-SPR-FR5CF**|**DXG-SPR-FR5CF**|2|
|Bus capacitor|**DXG-SPR-FR5BC**|**DXG-SPR-FR5BC**|2|
|Main power board|**DXG-SPR-2FR5MPB**|**DXG-SPR-4FR5MPB**|2|
|EMI-1 board|**DXG-SPR-2FR5E1B**|**DXG-SPR-4FR5E1B**|2|
|EMI-2 board|**DXG-SPR-2FR5E2B**|**DXG-SPR-4FR5E2B**|2|
|EMI-3 board|**DXG-SPR-FR5E3B**|**DXG-SPR-FR5E3B**|2|
|IGBT module|**DXG-SPR-FR5IGBT**|**DXG-SPR-FR5IGBT**|2|
|Rectifier module|**DXG-SPR-2FR5RM**|**DXG-SPR-4FR5RM**|2|
|Brake chopper module|**DXG-SPR-2FR5BCM**|**DXG-SPR-4FR5BCM**|2|
|Middle chassis cover|**DXG-SPR-FR5MCC**|**DXG-SPR-FR5MCC**|2|
|Outer housing|**DXG-SPR-FR5OH**|**DXG-SPR-FR5OH**|2|
|UL conduit plate|**DXG-SPR-FR5CPUL**|**DXG-SPR-FR5CPUL**|2|
|IEC conduit plate|**DXG-SPR-FR5IECCP**|**DXG-SPR-FR5IECCP**|2|
## _**Notes**_
> 1 Factory recommended spare parts.
> 2 575V available in 2015.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-39**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
## **Technical Data and Specifications**
|||
|---|---|
|**PowerXL Series—DG1 Technical Data and Specifications**<br>**Attribute**<br>**Description**<br>**Specification**||
|Input ratings|Input voltage Uin<br>208V to 240V, 380V to 500V, 525V to 600V, –15 to 10%|
||Input frequency<br>50 Hz to 60 Hz (variation up to 45 Hz to 66 Hz)|
||Connection to power<br>Once per minute or less|
||Starting delay<br>3s (FR1 to FR2), 4s (FR3), 5s (FR4), 6s (FR5)|
||Short-circuit withstand rating<br>100 kAIC|
|Output ratings|Output voltage<br>0 to Uin|
||Continuous output current<br>IL: ambient temperature maximum 40°C, up to 60°C with derating, overload 1.1 x IL (1 min./10 min.)<br>IH: ambient temperature maximum 50°C, up to 60°C with derating, overload 1.5 x IH (1 min./10 min.)|
||Overload current<br>150% respectively 110% (1 min./10 min.)|
||Initial output current<br>200% (2s/20s)|
||Output frequency<br>0–400 Hz (standard)|
||Frequency resolution<br>0.01 Hz|
|Control characteristics|Control methods<br>Frequency control<br>Speed control<br>Open-loop speed control<br>Open-loop torque control|
||Switching frequency<br>Range:<br>FR1–3: 1 kHz to 12 kHz<br>FR4–5: 1 kHz to 10 kHz<br>Defaults:<br>FR1–3: 4 kHz (IH), 6 kHz (IL)<br>FR4–5: 3.6 kHz<br>Automatic switching frequency derating in case of overload.|
||Frequency reference<br>Analog input: resolution 0.1% (10-bit), accuracy +1%<br>Panel reference: resolution 0.01 Hz|
||Field weakening point<br>20 Hz to 400 Hz|
||Acceleration time<br>0.1s to 3000s|
||Deceleration time<br>0.1s to 3000s|
||Braking torque<br>DC brake: 30% x Motor Rated Torque (Tn) (without brake chopper)<br>Dynamic braking (with optional brake chopper using an external brake resistor):<br>100% continuous maximum rating|
|Ambient conditions|Ambient operating temperature<br>–10°C (no frost) to +50°C, up to +60°C with derating (CT)<br>–10°C (no frost) to +40°C, up to +60°C with derating (VT)|
||Storage temperature<br>–40°C to +70°C|
||Relative humidity<br>0–95% RH, noncondensing, non-corrosive|
||Air quality:<br>●Chemical vapors<br>●Mechanical particles<br>Tested according to IEC 60068-2-60 Test Key:<br>Flowing mixed gas corrosion test, Method 1 (H2S [hydrogen sulfide] and SO2 [sulfur dioxide])<br>Designed according to:<br>IEC 60721-3-3, unit in operation, class 3C2<br>IEC 60721-3-3, unit in operation, class 3S2|
||Altitude<br>100% load capacity (no derating) up to 3280 ft (1000m); 1% derating for each 328 ft (100m) above<br>3280 ft (1000m); max. 9842 ft (3000m) (2000m for corner grounded earth main systems)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-40**
Adjustable Frequency Drives PowerXL DG1 Series Drives
2.4
|**PowerXL Series—DG1 Technical Data and Specifications, continued**<br>**Attribute**<br>**Description**<br>**Specification**|**PowerXL Series—DG1 Technical Data and Specifications, continued**<br>**Attribute**<br>**Description**<br>**Specification**|
|---|---|
|Ambient conditions,<br>continued|Vibration:<br>●EN 61800-5-1<br>●EN 60668-2-6<br>5–150 Hz<br>Displacement amplitude: 1 mm (peak) at 5 Hz to 15.8 Hz (FR1–FR5)<br>Maximum acceleration amplitude: 1g at 15.8 Hz to 150 Hz (FR1–FR5)|
||Shock:<br>●ISTA 1 A<br>●EN 60068-2-27<br>Storage and shipping: maximum 15g, 11 ms (in package)|
||Overvoltage<br>Overvoltage Category III|
||Pollution degree<br>Pollution Degree 2|
||Enclosure class<br>IP21/Type 1 standard in entire kW/hp range<br>IP54/Type 12 option<br>Note: Keypad required to be mounted in drive for IP54/Type 12 rating|
||Immunity<br>Fulfills EN 61800-3 (2004), first and second environment|
||MTBF<br>FR1: 165,457 hours<br>FR2: 134,833 hours<br>FR3: 102,515 hours<br>FR4: 121,567 hours<br>FR5: 108,189 hours<br>FR6: Available in 2015|
|Standards|Safety<br>UL 508C, CSA C22.2 No. 274-13 and EN 61800-5-1|
||EMC<br>+EMC2: EN 61800-3 (2004), Category C2<br>The drive can be modified for IT networks and corner grounding TN system|
||Electrostatic discharge<br>Second environment, IEC 61000-4-2, 4 kV CD or 8 kV AD, Criterion B|
||Fast transient burst<br>Second environment, IEC 61000-4-4, 2 kV/5 kHz, Criterion B|
||Dielectrical strength<br>Primary to secondary: 3600 Vac/5100 Vdc<br>Primary to earth: 2000 Vac/2828 Vdc|
||Approvals<br>EN 61800-5-1 (2007), CE, UL and cUL (see nameplate for more detailed approvals)|
|Fieldbus connections|Onboard: EtherNet/IP, Modbus®TCP, Modbus RTU, BACnet|
|Safety/protections|Overvoltage protection<br>Yes|
||Overvoltage trip limit<br>240V drives: 456V<br>480V drives: 911V|
||Undervoltage protection<br>Yes|
||Undervoltage trip limit<br>240V drives: 211V<br>480V drives: 370V|
||Earth fault protection<br>Yes|
||Input phase supervision<br>Yes|
||Motor phase supervision<br>Yes|
||Overcurrent protection<br>Yes|
||Unit overtemperature protection<br>Yes|
||Motor overload protection<br>Yes|
||Motor stall protection<br>Yes|
||Motor underload protection<br>Yes|
||DC bus overvoltage control<br>Yes|
||Short-circuit protection of 24V<br>reference voltages<br>Yes|
||Surge protection<br>Yes (differential mode 2 kV; common mode 4 kV)|
||Common coated boards<br>Yes (prevents corrosion)|
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-41**
Adjustable Frequency Drives
2.4
PowerXL DG1 Series Drives
## **Wiring Diagram**
**PowerXL Series—DG1 Control Wiring Diagram**
|**Powe**<br>R|**XL Ser**|**XL Ser**|**ies—DG1 Control Wiring Diagram**<br>**Pin**<br>**Signal Name Signal**<br>**Default Setting**<br>**Description**|
|---|---|---|---|
||||1<br>+10V<br>Ref. Output Voltage<br>—<br>10 Vdc Supply Source|
||es|||
||||2<br>AI1+<br>Analog Input 1<br>0–10V<br>Voltage Speed Reference (Programmable to 4 mA to 20 mA)|
||||3<br>AI1–<br>Analog Input 1 Ground<br>—<br>Analog Input 1 Common (Ground)|
||i|||
||||4<br>AI2+<br>Analog Input 2<br>4 mA to 20 mA<br>Current Speed Reference (Programmable to 0–10V)|
|||||
||||5<br>AI2–<br>Analog Input 2 Ground<br>—<br>Analog Input 2 Common (Ground)|
|||||
||||6<br>GND<br>I/O Signal Ground<br>—<br>I/O Ground for Reference and Control|
||||7<br>DIN5<br>Digital Input 5<br>Preset Speed B0<br>Sets frequency output to Preset Speed 1|
||||8<br>DIN6<br>Digital Input 6<br>Preset Speed B1<br>Sets frequency output to Preset Speed 2|
||||9<br>DIN7<br>Digital Input 7<br>Emergency Stop (TI–)<br>Input forces VFD output to shut off|
||||10<br>DIN8<br>Digital Input 8<br>Force Remote (TI+)<br>Input takes VFD from Local to Remote|
||||11<br>CMB<br>DI5 to DI8 Common<br>Grounded<br>Allows source input|
|||||
||||12<br>GND<br>I/O Signal Ground<br>—<br>I/O Ground for Reference and Control|
|||||
||||13<br>24V<br>+24 Vdc Output<br>—<br>Control voltage output (100 mA max.)|
|||||
||||14<br>DO1<br>Digital Output 1<br>Ready<br>Shows the drive is ready to run|
||||15<br>24Vo<br>+24 Vdc Output<br>—<br>Control voltage output (100 mA max.)|
||||16<br>GND<br>I/O Signal Ground<br>—<br>I/O Ground for Reference and Control|
|||||
||||17<br>AO1+<br>Analog Output 1<br>Output Frequency<br>Shows Output frequency to motor 0–60 Hz (4 mA to 20 mA)|
|||||
||||18<br>AO2+<br>Analog Output 2<br>Motor Current<br>Shows Motor current of motor 0–FLA (4 mA to 20 mA)|
||||19<br>24Vi<br>+24 Vdc Input<br>—<br>External control voltage input|
||||20<br>DIN1<br>Digital Input 1<br>Run Forward<br>Input starts drive in forward direction (start enable)|
|||||
||||21<br>DIN2<br>Digital Input 2<br>Run Reverse<br>Input starts drive in reverse direction (start enable)|
|||||
||||22<br>DIN3<br>Digital Input 3<br>External Fault<br>Input causes drive to fault|
|||||
||||23<br>DIN4<br>Digital Input 4<br>Fault Reset<br>Input resets active faults|
|||||
||||24<br>CMA<br>DI1 to DI4 Common<br>Grounded<br>Allows source input|
||||25<br>A<br>RS-485 Signal A<br>—<br>Fieldbus Communication (Modbus, BACnet)|
||||26<br>B<br>RS-485 Signal B<br>—<br>Fieldbus Communication (Modbus, BACnet)|
||||27<br>R3NO<br>Relay 3 Normally Open<br>At Speed<br>Relay output 3 shows VFD is at Ref. Frequency|
||||28<br>R1NC<br>Relay 1 Normally Closed<br>Run<br>Relay output 1 shows VFD is in a run state<br>29<br>R1CM<br>Relay 1 Common<br>30<br>R1NO<br>Relay 1 Normally Open|
||||31<br>R3CM<br>Relay 3 Common<br>At Speed<br>Relay output 3 shows VFD is at Ref. Frequency|
||||32<br>R2NC<br>Relay 2 Normally Closed<br>Fault<br>Relay output 2 shows VFD is in a fault state<br>33<br>R2CM<br>Relay 2 Common<br>34<br>R2NO<br>Relay 2 Normally Open|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-42**
Adjustable Frequency Drives PowerXL DG1 Series Drives
2.4
## **Control Board Layout**
## **PowerXL Series—DG1 Control Board Layout**
**==> picture [358 x 457] intentionally omitted <==**
**----- Start of picture text -----**<br>
Fan Power Wire Connect DSP Part<br>to Power Board<br>Keypad<br>STO<br>Connect MCU Part<br>AI Mode Selection to Power Board<br>Battery (Standard)<br>RJ45 EtherNet/IP,<br>Modbus TCP<br>Optional Card A<br>Control I/O Optional Card B<br>Terminals<br>ON<br>1<br>RS-485 Terminating<br>Resistor<br>Removable<br>MOV Screw<br>Removable<br>EMC Screw<br>Line Ground<br>Clamp Location<br>Motor Ground<br>Clamp Location<br>Line Ground<br>Clamp Location<br>Grounding<br>Grounding Strap Location<br>Strap Location<br>Line Side Motor<br>312 ON<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-43**
Adjustable Frequency Drives
PowerXL DG1 Series Drives
## 2.4
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2**
## **PowerXL Series—DG1 Dimensions**
||||W4||||D||||||**Weight**<br>**Lb (kg)**<br>**2**<br>**W3**<br>**W4**<br>**Ø**<br>W1<br>W2|**Weight**<br>**Lb (kg)**<br>**2**<br>**W3**<br>**W4**<br>**Ø**<br>W1<br>W2|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||||||
|H1|H2||||||||||||||
|||||||||||||H3|||
||||||||||||||W2||
||||||||||||||||
||||||||||||||||
||||||||||||||W||
||||||||||||||1||
||||W3||||||||||||
|**rame**<br>**Size**||**Voltage**<br>**hp (**|**CT/IH)**<br>**kW**|**Amperes**<br>**(CT/IH)**|**Approximate Dimensions in Inches (mm)**<br>**D**<br>**H1**<br>**H2**<br>**H3**<br>**W1**<br>**W**||||||||**2**<br>**W**||
|R1||230 Vac<br>0.75|–3<br>0.55–2.2|3.5–11|7.89<br>(200.4)<br>12.87<br>(326.9)<br>12.28<br>(311.9)<br>11.50<br>(292.1)<br>6.02<br>(153.0)<br>4.<br>(1||||||||80<br>21.9)<br>3.<br>(1|94<br>00.1)<br>3.94<br>(100.1)<br>0.28<br>(7.0)<br>14.33<br>(6.5)|
|||480 Vac<br>1–5|<br>0.75–3.7|2.3–7.6|||||||||||
|||575 Vac1<br>2–5|1.5–3.7|3.3–7.5|||||||||||
|R2||230 Vac<br>5–7|.5<br>3–5.5|12.5–25|9.63<br>(244.7)<br>16.50<br>(419.1)<br>15.98<br>(405.9)<br>14.96<br>(380.0)<br>6.61<br>(167.8)<br>5.<br>(1||||||||28<br>34.1)<br>3.<br>(9|54<br>0.0)<br>3.54<br>(90.0)<br>0.28<br>(7.0)<br>23.37<br>(10.6)|
|||480 Vac<br>7.5–|15<br>5.5–11|12–23|||||||||||
|||575 Vac1<br>7.5–|15<br>5.5–11|10–18|||||||||||
|R3||230 Vac<br>10–|15<br>7.5–11|31–48|10.44<br>(265.1)<br>21.97<br>(558.0)<br>21.46<br>(545.0)<br>20.43<br>(518.9)<br>8.06<br>(204.6)<br>7.<br>(1||||||||24<br>83.9)<br>4.<br>(1|92<br>25.0)<br>4.92<br>(125.0)<br>0.35<br>(9.0)<br>49.82<br>(22.6)|
|||480 Vac<br>20–|30<br>15–22|31–46|||||||||||
|||575 Vac1<br>20–|30<br>15–22|22–34|||||||||||
|R4||230 Vac<br>20–|30<br>15–22|61–88|11.57<br>(294.0)<br>24.80<br>(629.9)<br>34.31<br>(617.5)<br>23.27<br>(591.1)<br>9.36<br>(237.7)<br>9.<br>(2||||||||13<br>31.9)<br>8.<br>(2|07<br>05.0)<br>8.07<br>(205.0)<br>0.35<br>(9.0)<br>77.60<br>(35.2)|
|||480 Vac<br>40–|60<br>30–45|61–87|||||||||||
|||575 Vac1<br>40–|60<br>30–45|41–62|||||||||||
|R5||230 Vac<br>40–|60<br>30–45|114–170|13.41<br>(340.7)<br>34.98<br>(888.5)<br>29.65<br>(753.1)<br>27.83<br>(706.9)<br>11.34<br>(288.0)<br>11<br>(2||||||||.10<br>81.9)<br>8.<br>(2|66<br>20.0)<br>8.66<br>(220.0)<br>0.35<br>(9.0)<br>154.32<br>(70.0)|
|||480 Vac<br>75–|125<br>55–90|105–170|||||||||||
|||575 Vac1<br>75–|125<br>55–90|80–125|||||||||||
|R61||230 Vac<br>75–|100<br>55–75|211–261|1<br>1<br>1<br>1<br>1<br>1||||||||1|1<br>1<br>1|
|||480 Vac<br>150|–200<br>110–150|205–261|||||||||||
|||575 Vac1<br>150|–200<br>110–160|144–208|||||||||||
## _**Note**_
> 1 FR6 and 575 Vac available in 2015.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-44**
Adjustable Frequency Drives
2.5
SVX9000 Drives
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
SVX9000 Drives<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||**2**|
|---|---|---|
|**_Description_**|**_Page_**||
|SVX9000 Drives||**2**|
|SVX9000 Drives . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-48**||
|SVX9000 Enclosed Drives . . . . . . . . . . . . . . . .|**V6-T2-87**|**2**|
|SVX9000 VFD Pump Panels . . . . . . . . . . . . . . .|**V6-T2-111**|**2**|
## **Product Overview**
## **Application Description**
> With the SVX9000 Series **Application Engineering** Sensorless Vector Control, Proper selection and Eaton’s expanded Eaton drive application of all drive system offering now covers a components is essential to complete line of PWM assure that an adjustable adjustable frequency (speed) frequency drive system will drives in ratings from:
Proper selection and application of all drive system components is essential to assure that an adjustable frequency drive system will safely and reliably provide the performance required for any given application. The party responsible for the overall design and operation of the facility must make sure that qualified personnel are employed to select all components of the drive system, including appropriate safety devices. Eaton’s AF Drives Application Engineering Department is prepared to provide assistance to answer any questions about the technical capabilities of Eaton drives.
- 208V—3/4 to 100 hp IH; 1 to 100 hp IL
- 230V—3/4 to 100 hp IH; 1 to 125 hp IL
- 480V—1 to 1900 hp IH; 1-1/2 to 2200 hp IL
- 575V—2 to 2000 hp IH; 3 to 2300 hp IL
The Eaton family of drives includes DA1, DC1, H-Max, M-Max, SVX9000 and SPX9000. 9000X Series drive ratings are rated for either high overload (IH) or low overload (IL). IL indicates 110% overload capacity for 1 minute out of 10 minutes. IH indicates 150% overload capacity for 1 minute out of 10 minutes.
## _**Motor Selection**_
The basic requirement of motor selection is to match the torque vs. speed capability of the motor to the torque vs. speed requirement of the driven load.
A full range of enclosure types and options are available to meet a wide array of applications—from simple variable torque to more complex industrial applications such as conveyors, mixers and machine controls.
## _**Motor Torque vs. Speed Capability**_
As the speed of a motor is reduced below its 60 Hz base speed, motor cooling becomes less effective because of the reduced speed of the self-cooling fan. This limitation determines the maximum torque for continuous operation at any operating speed. The maximum intermittent operating torque is determined by the motor’s torque vs. current characteristics and the output current capability of the adjustable frequency controller.
## _**Multiple Motor Operation**_
A number of motors can be connected in parallel to a single controller. Since the frequency of the power supplied by the controller is the same for each motor, the motors will always operate at the same speed. Application Engineering assistance must be requested for all multiple motor applications to assure compliance with all controller design limitations.
## _**Special Types of Motors**_
Standard NEMA Designs A and B three-phase motors are the only motors recommended for use in the majority of applications, but other types of motors are occasionally used. If the existing motor used in the application or the motor proposed for use with the drive system is a type other than NEMA Design A or B, Application Engineering assistance must be requested to make certain that the drive is properly applied.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-45**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Product Selection Guide Features**
**2**
## **Controller Selection**
The basic requirement of controller selection is to match the output current, voltage and frequency capabilities of the controller with the requirements of the connected motor.
## _**Output Current**_
The controller must be selected and applied such that the average operating motor current and horsepower do not exceed the continuous current and horsepower ratings of the controller. The intermittent operating current must not exceed the intermittent current rating of the controller.
## _**Motor Protection**_
Eaton adjustable frequency drives include electronic motor overload protection circuits that are designed to meet the requirements of NEC article 430-2 provided that only one motor is connected to the output of the controller.
## _**Output Voltage and Frequency**_
When they are shipped, AF controllers are adjusted to provide a maximum output voltage and frequency equivalent to the input line voltage and frequency. The controllers can be adjusted to operate above line frequency, but a hazard of personal injury or equipment damage may exist when the motor is operated above base speed. Before adjusting the drive to operate above line frequency, make sure that the motor and the driven machinery can safely be operated at the resulting speed.
## **Controller Features**
## _**Operator Control and Interface Auxiliary Equipment and Requirements Accessories**_
Adjustable drives are generally designed to have a motor directly connected to the controller output terminals with no other equipment connected in series or parallel. Motor starters, disconnect switches, surge absorbers, DV/DT suppression circuits, output chokes, output transformers and any other equipment under consideration for installation on the output of the controller should not be installed without first requesting Application Engineering assistance. Power factor correction capacitors must never, under any circumstances, be connected at the output of the controller. They would serve no useful purpose, and they may damage the controller.
Since there are many possible configurations and many ways of achieving a specific end result, it pays to consider the operator control and interface requirements carefully. A simplified and more economical drive package can often be achieved by selecting from standard product offerings rather than specifying a custom designed configuration.
## _**Installation Compatibility**_
The successful application of an AC drive requires the assurance that the drive will be compatible with the environment in which it will be installed. In planning the installation, be sure to carefully consider the heat produced by the drive, the altitude and temperature limits and the need for clean cooling air. Other important considerations include acoustical noise, vibration, electromagnetic compatibility, power quality, controller input harmonic current and power distribution equipment requirements.
## _**Enclosure Definitions**_
- **NEMA Type 1/IP21** — Enclosures are intended for indoor use primarily to provide a degree of protection against contact with enclosed equipment and provide a degree of protection against a limited amount of falling dirt in locations where unusual service conditions do not exist. Top or side openings in the NEMA Type 1/IP21 enclosure allow for the free exchange of inside and outside air while meeting the UL rod entry and rust resistance design tests.
- **NEMA Type 12/IP54** —
Enclosures are intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt and dripping noncorrosive liquids. To meet UL drip, dust and rust resistance tests, NEMA Type 12/IP54 enclosures have no openings to allow for the exchange of inside and outside air.
- **Chassis IP00** —Similar to Protected Chassis IP20 except power terminals are protected by plastic shielding only. Primarily intended to be mounted inside a surrounding protective enclosure.
- **NEMA Type 3R** —Similar in design to NEMA Type 12/ IP54 except with more stringent design and test requirements.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-46**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Motor Protection**
## _**DV/DT and Peak Motor Voltage Solutions**_
Today’s AFD products offer significantly improved performance, but at the potential cost of motor insulation stress. The fast switching time of the IGBT devices used in newer AFDs can cause a transmission line effect in the output power leads to the motor, leading to possibly damaging voltage levels. To meet this need,
NEMA has introduced a motor in MG1, Part 31, which provides an insulation system designed to maintain normal motor life in AFD applications. For existing motors, a motor protection scheme is required for longer cable runs. Eaton offers three standard solutions for existing systems.
- **MotoRx** This solution provides an energy recovery system which clamps the peak motor voltage to a safe level for standard motors. This option is used when the distance between a single motor and the drive is 600 ft or less.
**2**
- **Output Line Reactor** This option provides an output line reactor, reducing the DV/DT of the AFD output voltage and lessening the transmission line effect, to lower the peak voltage at the motor terminals.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-47**
Adjustable Frequency Drives
2.5
SVX9000 Drives
**2** ~~J~~
## **SVX9000 Drives**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|SVX9000 Drives||
|Standards and Certifications . . . . . . . . . . . . . .|**V6-T2-49**|
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V6-T2-49**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-50**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-54**|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-55**|
|Replacement Parts . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-61**|
|Technical Data and Specifications . . . . . . . . . .|**V6-T2-70**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-71**|
|SVX9000 Enclosed Drives . . . . . . . . . . . . . . . . . . .|**V6-T2-87**|
|SVX9000 VFD Pump Panels . . . . . . . . . . . . . . . . .|**V6-T2-111**|
## **SVX9000 Drives**
## **Product Description**
SVX9000 Series Adjustable Frequency Drives from Eaton’s Electrical Sector are the next generation of drives specifically engineered for today’s commercial and industrial applications. The power unit makes use of the most sophisticated semiconductor technology and a highly modular construction that can be flexibly adapted to the customer’s needs.
The input and output configuration (I/O) is designed with modularity in mind. The I/O is compromised of option cards, each with its own input and output configuration. The control module is designed to accept a total of five of these cards. The cards contain not only normal analog and digital inputs but also fieldbus cards.
These drives continue the tradition of robust performance, and raise the bar on features and functionality, ensuring the best solution at the right price.
## **Features**
- Robust design—proven 500,000 hours MTBF
- Integrated 3% line reactors standard on drives from FR4 through FR9
- EMI/RFI Filters H standard up to 200 hp IH 480V, 100 hp IH 230V
- Simplified operating menu allows for typical programming changes, while programming mode provides control of everything
- Quick Start Wizard built into the programming of the drive ensures a smooth start-up
- Keypad can display up to three monitored parameters simultaneously
- LOCAL/REMOTE operation from keypad
- Copy/paste function allows transfer of parameter settings from one drive to the next
- Standard NEMA Type 12/ IP54 keypad on all drives
- The SVX can be flexibly ● Hand-held auxiliary 24V adapted to a variety of power supply allows needs using our preprogramming/monitoring installed “Seven in One” of control module without precision application applying full power to the programs consisting of: drive
- Control logic can be powered from an external auxiliary control panel, internal drive functions and fieldbus if necessary
- Basic
- Standard
- Local/remote
- Multi step speed control
- PID control
- Brake chopper standard from: 1–30 hp/380–500V 3/4–15 hp/208–230V
- Multi-purpose control
- Pump and fan control with auto change
- NEMA Type 1/IP21 and NEMA Type 12/IP54 enclosures available, Frame Sizes FR4–FR9
- Additional I/O and communication cards provide plug and play functionality
- Open chassis FR10 and greater
- I/O connections with simple quick connection terminals
- Standard option board configuration includes an A9 I/O board and an A2 relay output board installed in slots A and B
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-48**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Standards and Certifications**
## _**Product**_
- IEC 61800-2
## _**EMC (At Default Settings)**_
## _**Safety**_
- Immunity: Fulfills all EMC ● immunity requirements; ● CE Emissions: EN 61800-3, LEVEL H
> ● UL 508C
**2**
## **Catalog Number Selection**
## **SVX9000 Adjustable Frequency Drives**
**==> picture [502 x 237] intentionally omitted <==**
**----- Start of picture text -----**<br>
–<br>SVX 010 A 1 4 A 1 B 1 _ _ _ _ _ _<br>Product Family Board Modifications Options<br>SVX = Open drives 1 = Standard boards Options appear in alphabetical order.<br>SPX = Open drives FR10 and greater 2 = Conformal (varnished) coating [4] Extended I/O Card Options<br>B1 = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc<br>B2 = 1 RO (NC-NO), 1 RO (NO), 1 therm<br>Horsepower Rating Brake Chopper Options [2] B4 = 1 AI (mA isolated), 2 AO (mA isolated),<br>F07 = 3/4 hp 800 = 800 hp N = No brake chopper circuit 1 ext +24 Vdc/EXT + 24 Vdc<br>F15 = 1-1/2 hp 900 = 900 hp B = Internal brake chopper circuit B5 = 3 RO (NO)<br>007 = 7-1/2 hp H10 = 1000 hp B8 = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>010 = 10 hp H12 = 1200 hp B9 = 1 RO (NO), 5 DI 42–240 Vac input<br>050 = 50 hp H13 = 1350 hp Input Options [1] Communication Cards<br>125350700 = 125 hp = 350 hp = 700 hp H15H16H20 = 1500 hp = 1600 hp = 2000 hp 124 = Three-phase, EMC H = Three-phase, EMC N = Three-phase, EMC L CACICJ = Modbus TCP = BACnet = Johnson Controls N2<br>CQ = EtherNet/IP<br>C2 = Modbus<br>AFD Software Series Keypad C3 = PROFIBUS DP<br>A = Standard software A = Alphanumeric C4 = LonWorks<br>C5 = PROFIBUS DP (D9 connector)<br>Enclosure [3] Voltage Rating C6 = CANopen (slave)<br>0 = Chassis 2 = 230V (208–240) C7 = DeviceNet<br>1 = NEMA Type 1/IP21 4 = 480V (380–500) C8 = Modbus (D9 Type connector)<br>2 = NEMA Type 12/IP54 5 = 575V (525–690) D3 = RS-232 with D9 connection<br>**----- End of picture text -----**<br>
## _**Notes**_
- 1 All 230V drives and 480V drives up to 200 hp (IH) are only available with input option **1** (EMC Level H). 480V drives 250 hp (IH) or larger are available with input option **2** (EMC Level N). 480V drives are available with input option **4** (EMC Level L). 575V drives 200 hp (IH) or larger are only available with input option **2** . 575V drives up to 150 hp (IH) are only available with input option **4** (EMC Level L).
- 2 480V drives up to 30 hp (IH) are only available with brake chopper option **B** . 480V drives 40 hp (IH) or larger come standard with brake chopper option **N** . 230V drives up to 15 hp (IH) are only available with brake chopper option **B** . 230V drives 20 hp or larger come standard with brake chopper option
- **N** . All 575V drives come standard without brake chopper option (N). **N** = **No** brake chopper.
- 3 480V drives 250 hp (IH) and larger are available with enclosure style **0** (chassis); 690V drives 200 hp (IH) and larger are available with enclosure style **0** (chassis).
- 4 Factory promise delivery. Consult sales office for availability.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-49**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Product Selection**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**_230V SVX9000 Drives_**<br>**208–240V, NEMA Type 1/IP21 Drives**<br>**Frame**<br>**Size**<br>**hp (IH)**<br>**Current (IH)**<br>**hp (IL)**<br>FR4<br>3/4<br>3.7<br>1<br>1<br>4.8<br>1-1/2<br>1-1/2<br>6.6<br>2<br>2<br>7.8<br>3<br>**SVX9000 Open Drives**<br>~~a~~<br>of,~~TT~~|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**_230V SVX9000 Drives_**<br>**208–240V, NEMA Type 1/IP21 Drives**<br>**Frame**<br>**Size**<br>**hp (IH)**<br>**Current (IH)**<br>**hp (IL)**<br>FR4<br>3/4<br>3.7<br>1<br>1<br>4.8<br>1-1/2<br>1-1/2<br>6.6<br>2<br>2<br>7.8<br>3<br>**SVX9000 Open Drives**<br>~~a~~<br>of,~~TT~~|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**_230V SVX9000 Drives_**<br>**208–240V, NEMA Type 1/IP21 Drives**<br>**Frame**<br>**Size**<br>**hp (IH)**<br>**Current (IH)**<br>**hp (IL)**<br>FR4<br>3/4<br>3.7<br>1<br>1<br>4.8<br>1-1/2<br>1-1/2<br>6.6<br>2<br>2<br>7.8<br>3<br>**SVX9000 Open Drives**<br>~~a~~<br>of,~~TT~~|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**_230V SVX9000 Drives_**<br>**208–240V, NEMA Type 1/IP21 Drives**<br>**Frame**<br>**Size**<br>**hp (IH)**<br>**Current (IH)**<br>**hp (IL)**<br>FR4<br>3/4<br>3.7<br>1<br>1<br>4.8<br>1-1/2<br>1-1/2<br>6.6<br>2<br>2<br>7.8<br>3<br>**SVX9000 Open Drives**<br>~~a~~<br>of,~~TT~~|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**_230V SVX9000 Drives_**<br>**208–240V, NEMA Type 1/IP21 Drives**<br>**Frame**<br>**Size**<br>**hp (IH)**<br>**Current (IH)**<br>**hp (IL)**<br>FR4<br>3/4<br>3.7<br>1<br>1<br>4.8<br>1-1/2<br>1-1/2<br>6.6<br>2<br>2<br>7.8<br>3<br>**SVX9000 Open Drives**<br>~~a~~<br>of,~~TT~~|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**_230V SVX9000 Drives_**<br>**208–240V, NEMA Type 1/IP21 Drives**<br>**Frame**<br>**Size**<br>**hp (IH)**<br>**Current (IH)**<br>**hp (IL)**<br>FR4<br>3/4<br>3.7<br>1<br>1<br>4.8<br>1-1/2<br>1-1/2<br>6.6<br>2<br>2<br>7.8<br>3<br>**SVX9000 Open Drives**<br>~~a~~<br>of,~~TT~~|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**_230V SVX9000 Drives_**<br>**208–240V, NEMA Type 1/IP21 Drives**<br>**Frame**<br>**Size**<br>**hp (IH)**<br>**Current (IH)**<br>**hp (IL)**<br>FR4<br>3/4<br>3.7<br>1<br>1<br>4.8<br>1-1/2<br>1-1/2<br>6.6<br>2<br>2<br>7.8<br>3<br>**SVX9000 Open Drives**<br>~~a~~<br>of,~~TT~~|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**_230V SVX9000 Drives_**<br>**208–240V, NEMA Type 1/IP21 Drives**<br>**Frame**<br>**Size**<br>**hp (IH)**<br>**Current (IH)**<br>**hp (IL)**<br>FR4<br>3/4<br>3.7<br>1<br>1<br>4.8<br>1-1/2<br>1-1/2<br>6.6<br>2<br>2<br>7.8<br>3<br>**SVX9000 Open Drives**<br>~~a~~<br>of,~~TT~~|**Current (IL)**<br>4.8<br>6.6<br>7.8<br>11|**Catalog Number**<br>**SVXF07A1-2A1B1**<br>**SVX001A1-2A1B1**<br>**SVXF15A1-2A1B1**<br>**SVX002A1-2A1B1**|
|---|---|---|---|---|---|---|---|---|---|
||||||3|11|—|12.5|**SVX003A1-2A1B1**|
|**2**||||FR5|—|12.5|5|17.5|**SVX004A1-2A1B1**|
|**2**|||||5<br>7-1/2|17.5<br>25|7-1/2<br>10|25<br>31|**SVX005A1-2A1B1**<br>**SVX007A1-2A1B1**|
|**2**||||FR6|10|31|15|48|**SVX010A1-2A1B1**|
||||||15|48|20|61|**SVX015A1-2A1B1**|
|**2**||||FR7|20|61|25|75|**SVX020A1-2A1N1**|
||||||25|75|30|88|**SVX025A1-2A1N1**|
|**2**|||||30|88|40|114|**SVX030A1-2A1N1**|
|**2**||||FR8|40<br>50|114<br>140|50<br>60|140<br>170|**SVX040A1-2A1N1**<br>**SVX050A1-2A1N1**|
|**2**|||||60|170|75|205|**SVX060A1-2A1N1**|
|||||FR9|75|205|100|261|**SVX075A1-2A1N1**|
|**2**|||||100|261|125|300|**SVX100A1-2A1N1**|
## **208–240V, NEMA Type 12/IP54 Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR4|3/4|3.7|1|4.8|**SVXF07A2-2A1B1**|
||1<br>1-1/2|4.8<br>6.6|1-1/2<br>2|6.6<br>7.8|**SVX001A2-2A1B1**<br>**SVXF15A2-2A1B1**|
||2|7.8|3|11|**SVX002A2-2A1B1**|
||3|11|—|12.5|**SVX003A2-2A1B1**|
|FR5|—|12.5|5|17.5|**SVX004A2-2A1B1**|
||5|17.5|7-1/2|25|**SVX005A2-2A1B1**|
||7-1/2|25|10|31|**SVX007A2-2A1B1**|
|FR6|10<br>15|31<br>48|15<br>20|48<br>61|**SVX010A2-2A1B1**<br>**SVX015A2-2A1B1**|
|FR7|20|61|25|75|**SVX020A2-2A1N1**|
||25|75|30|88|**SVX025A2-2A1N1**|
||30|88|40|114|**SVX030A2-2A1N1**|
|FR8|40|114|50|140|**SVX040A2-2A1N1**|
||50|140|60|170|**SVX050A2-2A1N1**|
|FR9|60<br>75|170<br>205|75<br>100|205<br>261|**SVX060A2-2A1N1**<br>**SVX075A2-2A1N1**|
||100|261|125|300|**SVX100A2-2A1N1**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-50**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**480V SVX9000 Drives**_
|**SVX9000 Open Drives**|**SVX9000 Open Drives**|**380–500V, NEMA Type 1/IP21 Drives**|**380–500V, NEMA Type 1/IP21 Drives**|**380–500V, NEMA Type 1/IP21 Drives**|**380–500V, NEMA Type 1/IP21 Drives**|||
|---|---|---|---|---|---|---|---|
|||**Frame**||||||
|||**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|||FR4|1|2.2|1-1/2|3.3|**SVX001A1-4A1B1**|
||||1-1/2|3.3|2|4.3|**SVXF15A1-4A1B1**|
||||2|4.3|3|5.6|**SVX002A1-4A1B1**|
||||3|5.6|5|7.6|**SVX003A1-4A1B1**|
||||5|7.6|—|9|**SVX005A1-4A1B1**|
||||—|9|7-1/2|12|**SVX006A1-4A1B1**|
|||FR5|7-1/2|12|10|16|**SVX007A1-4A1B1**|
||||10|16|15|23|**SVX010A1-4A1B1**|
||||15|23|20|31|**SVX015A1-4A1B1**|
|||FR6|20|31|25|38|**SVX020A1-4A1B1**|
||||25|38|30|46|**SVX025A1-4A1B1**|
||||30|46|40|61|**SVX030A1-4A1B1**|
|||FR7|40|61|50|72|**SVX040A1-4A1N1**|
||||50|72|60|87|**SVX050A1-4A1N1**|
||||60|87|75|105|**SVX060A1-4A1N1**|
|||FR8|75|105|100|140|**SVX075A1-4A1N1**|
||||100|140|125|170|**SVX100A1-4A1N1**|
||||125|170|150|205|**SVX125A1-4A1N1**|
|||FR9|150|205|200|261|**SVX150A1-4A1N1**|
||||200|245|250|300|**SVX200A1-4A1N1**|
**2**
## **380–500V, NEMA Type 12/IP54 Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR4|1|2.2|1-1/2|3.3|**SVX001A2-4A1B1**|
||1-1/2|3.3|2|4.3|**SVXF15A2-4A1B1**|
||2|4.3|3|5.6|**SVX002A2-4A1B1**|
||3|5.6|5|7.6|**SVX003A2-4A1B1**|
||5|7.6|—|9|**SVX005A2-4A1B1**|
||—|9|7-1/2|12|**SVX006A2-4A1B1**|
|FR5|7-1/2|12|10|16|**SVX007A2-4A1B1**|
||10|16|15|23|**SVX010A2-4A1B1**|
||15|23|20|31|**SVX015A2-4A1B1**|
|FR6|20|31|25|38|**SVX020A2-4A1B1**|
||25|38|30|46|**SVX025A2-4A1B1**|
||30|46|40|61|**SVX030A2-4A1B1**|
|FR7|40|61|50|72|**SVX040A2-4A1N1**|
||50|72|60|87|**SVX050A2-4A1N1**|
||60|87|75|105|**SVX060A2-4A1N1**|
|FR8|75|105|100|140|**SVX075A2-4A1N1**|
||100|140|125|170|**SVX100A2-4A1N1**|
||125|170|150|205|**SVX125A2-4A1N1**|
|FR9|150|205|200|261|**SVX150A2-4A1N1**|
||200|245|250|300|**SVX200A2-4A1N1**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-51**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **2 SVX9000 Open Drives 380–500V, Open Chassis Drives Frame 2 Size hp (IH) Current (IH)**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**<br>FR101|**hp (IH)H))**<br>250|**Current (IH)H))**<br>330|**hp (IL)**<br>300|**Current (IL)**<br>385|**Catalog Number**<br>**SPX250A0-4A2N1**|
||300|385|350|460|**SPX300A0-4A2N1**|
||350|460|400|520|**SPX350A0-4A2N1**|
|FR11|400|520|500|590|**SPX400A0-4A2N1**|
||500|590|—|650|**SPX500A0-4A2N1**|
||—|650|600|730|**SPX550A0-4A2N1**|
|FR12|600|730|—|820|**SPX600A0-4A2N1**|
||—|820|700|920|**SPX650A0-4A2N1**|
||700|920|800|1030|**SPX700A0-4A2N1**|
|FR13|800|1030|900|1150|**SPX800A0-4A2N1**|
||900|1150|1000|1300|**SPX900A0-4A2N1**|
|FR14|1000<br>1200|1300<br>1600|1200<br>1500|1450<br>1770|**SPXH10A0-4A2N1**<br>**SPXH12A0-4A2N1**|
||1600|1940|1800|2150|**SPXH16A0-4A2N1**|
||1900|2300|2200|2700|**SPXH19A0-4A2N1**|
## _**575V SVX9000 Drives**_
**525–690V, NEMA Type 1/IP21 Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR6|2|3.3|3|4.5|**SVX002A1-5A4N1**|
||3|4.5|—|5.5|**SVX003A1-5A4N1**|
||—|5.5|5|7.5|**SVX004A1-5A4N1**|
||5|7.5|7-1/2|10|**SVX005A1-5A4N1**|
||7-1/2<br>10|10<br>13.5|10<br>15|13.5<br>18|**SVX007A1-5A4N1**<br>**SVX010A1-5A4N1**|
||15|18|20|22|**SVX015A1-5A4N1**|
||20|22|25|27|**SVX020A1-5A4N1**|
||25|27|30|34|**SVX025A1-5A4N1**|
|FR7|30<br>40|34<br>41|40<br>50|41<br>52|**SVX030A1-5A4N1**<br>**SVX040A1-5A4N1**|
|FR8|50|52|60|62|**SVX050A1-5A4N1**|
||60|62|75|80|**SVX060A1-5A4N1**|
||75|80|100|100|**SVX075A1-5A4N1**|
|FR9|100|100|125|125|**SVX100A1-5A4N1**|
||125|125|150|144|**SVX125A1-5A4N1**|
||150<br>—|144<br>170|—<br>200|170<br>208|**SVX150A1-5A4N1**<br>**SVX175A1-5A4N1**|
## _**Note**_
1 FR10–FR14 includes 3% line reactor, but it is not integral to chassis.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-52**
Adjustable Frequency Drives
2.5
SVX9000 Drives
|**SVX9000 Open Drives**|**SVX9000 Open Drives**|**525–690V, NEMA Type 12/IP54 Drives**|**525–690V, NEMA Type 12/IP54 Drives**|**525–690V, NEMA Type 12/IP54 Drives**|**525–690V, NEMA Type 12/IP54 Drives**|||
|---|---|---|---|---|---|---|---|
|||**Frame**||||||
|||**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|||FR6|2|3.3|3|4.5|**SVX002A2-5A4N1**|
||||3|4.5|—|5.5|**SVX003A2-5A4N1**|
||||—|5.5|5|7.5|**SVX004A2-5A4N1**|
||||5|7.5|7-1/2|10|**SVX005A2-5A4N1**|
||||7-1/2|10|10|13.5|**SVX007A2-5A4N1**|
||||10|13.5|15|18|**SVX010A2-5A4N1**|
||||15|18|20|22|**SVX015A2-5A4N1**|
||||20|22|25|27|**SVX020A2-5A4N1**|
||||25|27|30|34|**SVX025A2-5A4N1**|
|||FR7|30|34|40|41|**SVX030A2-5A4N1**|
||||40|41|50|52|**SVX040A2-5A4N1**|
|||FR8|50|52|60|62|**SVX050A2-5A4N1**|
||||60|62|75|80|**SVX060A2-5A4N1**|
||||75|80|100|100|**SVX075A2-5A4N1**|
|||FR9|100|100|125|125|**SVX100A2-5A4N1**|
||||125|125|150|144|**SVX125A2-5A4N1**|
||||150|144|—|170|**SVX150A2-5A4N1**|
||||—|170|200|208|**SVX175A2-5A4N1**|
**2**
## **525–690V, Open Chassis Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR10|200|208|250|261|**SPX200A0-5A2N1**|
||250|261|300|325|**SPX250A0-5A2N1**|
||300|325|400|385|**SPX300A0-5A2N1**|
|FR11|400|385|450|460|**SPX400A0-5A2N1**|
||450|460|500|502|**SPX450A0-5A2N1**|
||500|502|—|590|**SPX500A0-5A2N1**|
|FR12|—|590|600|650|**SPX550A0-5A2N1**|
||600|650|700|750|**SPX600A0-5A2N1**|
||700|750|800|820|**SPX700A0-5A2N1**|
|FR13|800|820|900|920|**SPX800A0-5A2N1**|
||900|920|1000|1030|**SPX900A0-5A2N1**|
||1000|1030|1250|1180|**SPXH10A0-5A2N1**|
|FR14|1350|1300|1500|1500|**SPXH13A0-5A2N1**|
||1500|1500|2000|1900|**SPXH15A0-5A2N1**|
||2000|1900|2300|2250|**SPXH20A0-5A2N1**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-53**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Accessories**
**2**
## _**Demo Drive and Power Supply**_
## **Demo Drive and Power Supply**
|**Description**|**Catalog Number**|
|---|---|
|9000X demo drive|**9000XDEMO**|
## _**NEMA Type 12/IP54 Conversion Kit**_
The NEMA Type 12/IP54 kit option is used to convert a NEMA Type 1/IP21 to a NEMA Type 12/IP54 drive. The NEMA Type 12/IP54
kit consists of a metal drive shroud, fan kit for some frames, adaptor plate and plugs.
## **NEMA Type 12/IP54 Conversion Kit**
|**Frame Size**<br>**Delivery Code**|**Approximate Dimensions in Inches (mm)**<br>**Approximate**<br>**Weight Lb (kg)**<br>**Length**<br>**Width**<br>**Height**<br>**Catalog Number**|
|---|---|
|FR4<br>W<br>FR5<br>FR6|13 (330)<br>7 (178)<br>4 (102)<br>4 (1.8)<br>**OPTN12FR4**|
||16 (406)<br>8 (203)<br>7 (178)<br>5 (2.3)<br>**OPTN12FR5**|
||21 (533)<br>10 (254)<br>5 (127)<br>7 (3.2)<br>**OPTN12FR6**|
## _**Flange Kits**_
## **Flange Kit NEMA Type 12/ IP54**
The flange kit is utilized when the power section is mounted through the back panel of an enclosure. Includes flange mount brackets and NEMA Type 12/IP54 fan components. Metal shroud not included.
Flange kits for NEMA Type 12/IP54 enclosure drive rating are determined by rating of drive.
**Flange Kit NEMA Type 12/ IP54—Frames 4–9**
|are etermne y ratng o<br>drive.<br>**Flange Kit NEMA Type 12/**<br>**IP54— Frames 4, 5 and 6**1<br>**Frame**<br>**Size**<br>**Delivery**<br>**Code**<br>**Catalog**<br>**Number**<br>FR4<br>W<br>**OPTTHRFR4**<br>FR5<br>**OPTTHRFR5**<br>FR6<br>**OPTTHRFR6**|**Frame**<br>**Size**<br>**Delivery**<br>**Code**|**Catalog**<br>**Number**|
|---|---|---|
||FR4<br>FP<br>FR5<br>FR6<br>FR7<br>FR8<br>FR9|**OPTTHR4**|
|||**OPTTHR5**|
|||**OPTTHR6**|
|||**OPTTHR7**|
|FR4<br>W<br>FR5<br>FR6|||
|||**OPTTHR8**|
|||**OPTTHR9**|
## _**Note**_
> 1 For installation of an SVX9000 NEMA Type 1/IP21 drive into a NEMA Type 12/IP54 oversized enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-54**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Options**
## _**9000X Series Option Board Kits**_
The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is designed to accept a total of five option boards.
**2**
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2 relay output board, which are installed in slots A and B.
## **Option Boards**
## **Option Board Kits**
|A<br>B C D E|**Option Kit Description**1<br>**Allowed Slot**<br>**Locations**2<br>**Field**<br>**Installed**<br>**Factory**<br>**Installed**<br>**SVX Ready Programs**<br>**Catalog**<br>**Number**<br>**Option**<br>**Designator**<br>**Basic**<br>**Local/**<br>**Remote**<br>**Standard**<br>**MSS**<br>**PID**<br>**Multi-P.**<br>**PFC**|
|---|---|
||**Standard I/O Cards**|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/EXT +24 Vdc<br>A<br>**OPTA9**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||2 RO (NC-NO)<br>B<br>**OPTA2**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||**Extended I/O Cards**|
||2 RO, therm—SPX only<br>B<br>**OPTA3**<br>**A3**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Encoder low volt +5V/15V/24V—SPX only<br>C<br>**OPTA4**<br>**A4**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Encoder high volt +15V/24V—SPX only<br>C<br>**OPTA5**<br>**A5**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Double encoder—SPX only<br>C<br>**OPTA7**<br>**A7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 DO, 2 AI, 1 AO—SPX only<br>A<br>**OPTA8**<br>**A8**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||3 DI (encoder 10–24V), out +15V/+24V,<br>2 DO (pulse+direction)—SPX only<br>C<br>**OPTAE**<br>**AE**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 ext +24 Vdc/EXT +24 Vdc<br>B, C,**D**, E<br>**OPTB1**<br>**B1**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 RO (NC-NO), 1 RO (NO), 1 therm<br>B, C,**D**, E<br>**OPTB2**<br>**B2**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 AI (mA isolated), 2 AO (mA isolated),<br>1 ext +24 Vdc/EXT +24 Vdc<br>B, C,**D**, E<br>**OPTB4**<br>**B4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||3 RO (NO)<br>B, C,**D**, E<br>**OPTB5**<br>**B5**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>B, C,**D**, E<br>**OPTB8**<br>**B8**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||1 RO (NO), 5 DI 42–240 Vac input<br>B, C,**D**, E<br>**OPTB9**<br>**B9**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||**Communication Cards**|
||Modbus3<br>D,**E**<br>**OPTC2**<br>**C2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Johnson Controls N23<br>D,**E**<br>**OPTC2**<br>**CA**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||Modbus TCP<br>D,**E**<br>**OPTCI**<br>**CI**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||BACnet<br>D,**E**<br>**OPTCJ**<br>**CJ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||EtherNet/IP<br>D,**E**<br>**OPTCQ**<br>**CQ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP<br>D,**E**<br>**OPTC3**<br>**C3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||LonWorks<br>D,**E**<br>**OPTC4**<br>**C4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP (D9 connector)<br>D,**E**<br>**OPTC5**<br>**C5**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||CANopen (slave)4<br>D,**E**<br>**OPTC6**<br>**C6**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||DeviceNet<br>D,**E**<br>**OPTC7**<br>**C7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Modbus (D9 type connector)<br>D,**E**<br>**OPTC8**<br>**C8**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Adapter—SPX only<br>D,**E**<br>**OPTD1**<br>**D1**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Adapter—SPX only<br>D,**E**<br>**OPTD2**<br>**D2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||RS-232 with D9 connection<br>D,**E**<br>**OPTD3**<br>**D3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
## _**Notes**_
- 1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
- 2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
- 3 OPTC2 is a multi-protocol option card.
- 4 SPX9000 drives only (FR10 and larger).
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-55**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Modbus RTU Network Communications**
The Modbus Network Card **2** OPTC2 is used for connecting the 9000X Drive as a slave on **2** a Modbus network. The interface is connected by a **2** 9-pin DSUB connector (female) and the baud rate **2** ranges from 300 to 19200 baud. Other communication parameters include an **2** address range from 1 to 247; a parity of None, Odd or **2** Even; and the stop bit is 1.
## **PROFIBUS Network Communications**
The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS-DP network. The interface is connected by a 9-pin DSUB connector (female). The baud rates range from 9.6K baud to 12M baud, and the addresses range from 1 to 127.
## **LonWorks Network Communications**
The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network. This interface uses Standard Network Variable Types (SNVT) as data types. The channel connection is achieved using a FTT-10A Free Topology transceiver via a single twisted transfer cable. The communication speed with LonWorks is 78 kBits/s.
## **CANopen (Slave) Communications**
The CANopen (Slave) Network Card OPTC6 is used for connecting the 9000X Drive to a host system. According to ISO11898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms, and specific line delay of nominal 5 nS/m. 120 ohms line termination resistors required for installation.
## **DeviceNet Network Communications**
The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network. It includes a 5.08 mm pluggable connector. Transfer method is via CAN using a two-wire twisted shielded cable with two-wire bus power cable and drain. The baud rates used for communication include 125K baud, 250K baud and 500K baud.
## **Johnson Controls Metasys N2 Network Communications**
The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. The N2 fieldbus is available as a factory installed option and as a field installable kit.
## **Modbus/TCP Network Communications**
The Modbus/TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks utilizing Modbus protocol. It includes an RJ-45 pluggable connector. This interface provides a selection of standard and custom register values to communicate drive parameters. The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable over Ethernet using a supplied software tool.
## **BACnet Network Communications**
The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks. It includes a 5.08 mm pluggable connector. Data transfer is Master-Slave/ Token Passing (MS/TP) RS-485. This interface uses a collection of 30 Binary Value Objects (BVOs) and 35 Analog Value Objects (AVOs) to communicate drive parameters. The card supports 9.6, 19.2 and 38.4 Kbaud communication speeds and supports network addresses 1–127.
## **EtherNet/IP Network Communications**
The EtherNet/IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet/Industrial Protocol networks. It includes an RJ-45 pluggable connector. The interface uses CIP objects to communicate drive parameters (CIP is “Common Industrial Protocol”, the same protocol used by DeviceNet). The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable by Static, BOOTP and DHCP methods.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-56**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**Control Panel Options**_
## **Factory Options**
|**Factory Options**|||
|---|---|---|
||**Factory Installed**|**Field Installed**|
|||**NEMA Type 1/IP21**|
|**Description**|**Option Code**|**Catalog Number**|
|**Local/Remote Keypad SVX9000 Control Panel—**This option is standard on all drives and|**A**|**KEYPAD-LOC/REM**|
|consists of an RS-232 connection, backlit alphanumeric LCD display with nine indicators for the|||
|RUN status and two indicators for the control source. The nine pushbuttons on the panel are used|||
|for panel programming and monitoring of all SVX9000 parameters. The panel is detachable and|||
|isolated from the input line potential. Include LOC/REM key to choose control location.|||
|**Keypad Remote Mounting Kit—**This option is used to remote mount the SVX9000 keypad. The|**—**|**OPTRMT-KIT-9000X**|
|footprint is compatible to the SV9000 remote mount kit. Includes 10 ft cable, keypad holder and|||
|mounting hardware.|||
**2**
## **Miscellaneous Options**
|**Miscellaneous Options**||
|---|---|
|**Description**|**Catalog Number**|
|**9000XDrive**—A PC-based tool for controlling and monitoring of the SVX9000. Features include: loading parameters that|**9000XDRIVE**|
|can be saved to a file or printed, setting references, starting and stopping the motor, monitoring signals in graphical or text||
|form, and real-time display. To avoid damage to the drive or computer, SVDrivecable must be used.||
|**SVDrivecable**—6 ft (1.8m) RS-232 cable (22 gauge) with a 7-pin connector on each end. Should be used in conjunction|**SVDRIVECABLE**|
|with the 9000XDrive option to avoid damage to the SVX9000 or computer. The same cable can be used for downloading||
|specialized applications to the drive.||
|**External Dynamic Braking Resistors**—Used with the dynamic braking chopper circuit to absorb motor regenerative|See**Page** **V6-T2-58**|
|energy for stopping the load and to dissipate the energy flowing back into the drive. Resistors are separated into standard||
|duty and heavy-duty. Standard duty is defined as 20% duty or less with 100% braking torque, while heavy-duty is defined as||
|50% duty or less with 150% braking torque.||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-57**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**Open Drive Options**_
## **Brake Chopper Options**
**2**
The brake chopper circuit option is used for applications that require dynamic braking. Dynamic braking resistors are not included with drive purchase. Consult the factory for additional dynamic braking resistor selections that are supplied separately. A list of common resistors are listed below and are complete indoor assemblies, include a pre-wired terminal block and a thermal switch, and are not UL Listed.
## _**Duty Cycle**_
The duty cycle rating is based on a 60-second period. For example, the 20% duty cycle resistor can carry 100% current for 12 seconds out of every 60 seconds, while the 50% duty cycle resistor can carry 150% current for 30 seconds out of every 60 seconds.
## _**Torque**_
If the braking torque required is less than 15%, dynamic braking is not required because the regenerated energy will be dissipated in the drive and motor losses.
## **Dynamic Brake Resistor—Catalog Number Selection**
**– – DBR R100 W0800**
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||||
||||**Dynamic Brake Resistor**||||**Resistance**||||**Rated Watts**|||
||||||**1D0**= 1.0 Ohms<br>**100**= 100 Ohms|||||**0800**= 800 Watts<br>**8000**= 8000 Watts||||
|||||||||||**080K**= 80,000 Watts||||
|**230V Brake Resistors**||||||||||||||
|**Drive hp**<br>**(CT/IH)**|**Minimum**<br>**Ohms**||**20% Duty Cycle, 100% Torque**<br>**Catalog Number**<br>**Dimensions**||||**50% Duty Cycle, 150% Torque**<br>**(Inches)**<br>**Catalog Number**<br>**Dimensions (Inches)**|||||||
|0.75|30.0||**DBR-R100-W0400**||12W x 5D x 5H<br>**DBR-R100-W0800**|||||||12W x 7D x 5H||
|1|30.0||**DBR-R100-W0400**||12W x 5D x 5H<br>**DBR-R100-W0800**|||||||12W x 7D x 5H||
|1.5|30.0||**DBR-R100-W0400**||12W x 5D x 5H<br>**DBR-R036-W1200**|||||||12W x 10D x 5H||
|2|30.0||**DBR-R100-W0400**||12W x 5D x 5H<br>**DBR-R036-W1200**|||||||12W x 10D x 5H||
|3|30.0||**DBR-R036-W0800**||12W x 7D x 5H<br>**DBR-R036-W2000**|||||||12W x 16D x 5H||
|4<br>5|30.0<br>30.0||**DBR-R036-W0800**<br>**DBR-R036-W0800**||12W x 7D x 5H<br>**DBR-R030-W2400**<br>12W x 7D x 5H<br>**DBR-R030-W2800**|||||||19W x 10D x 5H<br>19W x 13D x 5H||
|7.5|20.0||**DBR-R020-W1200**||12W x 10D|x 5H<br>**DBR-R020-W4800**||||||26.5W x 13D x 5H||
|10|10.0||**DBR-R015-W1600**||12W x 13D|x 5H<br>**DBR-R112-W6000**||||||26.5W x 13D x 5H||
|15|10.0||**DBR-R012-W2400**||19W x 10D|x 5H<br>**DBR-R010-W9000**||||||28W x 10D x 10H||
|20|3.3||**DBR-R9D3-W3200**||19W x 10D|x 5H<br>**DBR-R3D4-W012K**||||||28W x 10D x 10H||
|25|3.3||**DBR-R5D5-W4000**||26.5W x 10D x 5H<br>**DBR-R5D1-W015K**|||||||28W x 16D x 10H||
|30|3.3||**DBR-R4D8-W4800**||26.5W x 10D x 5H<br>**DBR-R4D1-W020K**|||||||28W x 16D x 10H||
|40|1.4||**DBR-R004-W6000**||26.5W x 13D x 5H<br>**DBR-R3D4-W025K**|||||||30W x 18D x 16H||
|50|1.4||**DBR-R3D1-W7500**||26.5W x 16D x 5H<br>**DBR-R2D1-W030K**|||||||30W x 18D x 24H||
|60|1.4||**DBR-R2D8-W9000**||26.5W x 16D x 5H<br>**DBR-R002-W036K**|||||||30W x 18D x 24H||
|75|1.4||**DBR-R2D6-W012K**||28W x 10D|x 10H<br>**DBR-R1D5-W045K**||||||30W x 18D x 32H||
|100|1.4||**DBR-R002-W015K**||28W x 16D|x 10H<br>**DBR-R1D4-W060K**||||||30W x 18D x 40H||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-58**
Adjustable Frequency Drives
2.5
SVX9000 Drives
**480V Brake Resistors**
|**Drive hp**|**Minimum**|**20% Duty Cycle, 100%**|**Torque**|**50% Duty Cycle, 150%**|**Torque**|
|---|---|---|---|---|---|
|**(CT/IH)**|**Ohms**|**Catalog Number**|**Dimensions (Inches)**|**Catalog Number**|**Dimensions (Inches)**|
|1|63.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W0800**|12W x 7D x 5H|
|1.5|63.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W1200**|12W x 10D x 5H|
|2|63.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W1200**|12W x 10D x 5H|
|3|63.0|**DBR-R100-W0800**|12W x 7D x 5H|**DBR-R100-W2000**|12W x 16D x 5H|
|5|63.0|**DBR-R100-W0800**|12W x 7D x 5H|**DBR-R100-W2800**|19W x 13D x 5H|
|6|63.0|**DBR-R100-W1200**|12W x 10D x 5H|**DBR-R070-W4000**|19W x 16D x 5H|
|7.5|63.0|**DBR-R100-W1200**|12W x 10D x 5H|**DBR-R063-W4800**|26.5W x 13D x 5H|
|10|63.0|**DBR-R063-W1600**|12W x 13D x 5H|**DBR-R063-W6000**|26.5W x 16D x 5H|
|15|42.0|**DBR-R042-W2400**|19W x 10D x 5H|**DBR-R042-W9000**|28W x 10D x 10H|
|20|21.0|**DBR-R030-W3200**|19W x 13D x 5H|**DBR-R023-W012K**|28W x 13D x 10H|
|25|21.0|**DBR-R030-W4000**|19W x 16D x 5H|**DBR-R021-W015K**|28W x 13D x 10H|
|30|14.0|**DBR-R020-W4800**|26.5W x 13D x 5H|**DBR-R014-W020K**|30W x 18D x 24H|
|40|6.5|**DBR-R112-W6000**|26.5W x 13D x 5H|**DBR-R007-W025K**|30W x 18D x 16H|
|50|6.5|**DBR-R013-W7500**|26.5W x 16D x 5H|**DBR-R8D5-W030K**|30W x 18D x 24H|
|60|6.5|**DBR-R010-W9000**|28W x 10D x 10H|**DBR-R7D3-W036K**|30W x 18D x 24H|
|75|3.3|**DBR-R009-W012K**|28W x 13D x 10H|**DBR-R3D3-W045K**|30W x 18D x 32H|
|100|3.3|**DBR-R5D1-W015K**|28W x 16D x 10H|**DBR-R004-W060K**|30W x 18D x 40H|
|125|3.3|**DBR-R4D1-W020K**|28W x 16D x 10H|**DBR-R004-W070K**|30W x 18D x 48H|
|150|3.3|**DBR-R3D4-W025K**|30W x 18D x 16H|**DBR-R3D5-W085K**|30W x 18D x 56H|
|200|3.3|**DBR-R3D3-W030K**|30W x 18D x 24H|**DBR-R3D3-W110K**|30W x 18D x 72H|
|250|1.4|**DBR-R2D5-W036K**|30W x 18D x 24H|1|—|
|300|1.4|**DBR-R1D5-W045K**|30W x 18D x 32H|1|—|
|350|1.4|**DBR-R1D4-W060K**|30W x 18D x 40H|1|—|
|400|0.9|**DBR-R1D4-W060K**|30W x 18D x 40H|1|—|
|500|0.9|**DBR-R0D9-W080K**|30W x 18D x 48H|1|—|
|550|0.9|**DBR-R001-W085K**|30W x 18D x 56H|1|—|
**2**
## _**Note**_
> 1 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-59**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **575V Brake Resistors**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**e essos**<br>**Drive hp**<br>**(CT/IH)**<br>**Minimum**<br>**Ohms**<br>**20% Duty Cycle, 100% Torque**<br>**50% Duty Cycle, 150% Torque**<br>**Catalog Number**<br>**Dimensions (Inches)**<br>**Catalog Number**<br>**Dimensions (Inches)**|
|---|---|
||2<br>100.0<br>**DBR-R100-W0400**<br>12W x 5D x 5H<br>**DBR-R100-W1200**<br>12W x 10D x 5H|
||3<br>100.0<br>**DBR-R100-W0800**<br>12W x 7D x 5H<br>**DBR-R100-W2000**<br>12W x 16D x 5H|
||4<br>100.0<br>**DBR-R100-W0800**<br>12W x 7D x 5H<br>**DBR-R100-W2400**<br>19W x 10D x 5H|
||5<br>100.0<br>**DBR-R100-W0800**<br>12W x 7D x 5H<br>**DBR-R100-W2800**<br>19W x 13D x 5H|
||7.5<br>100.0<br>**DBR-R100-W1200**<br>12W x 10D x 5H<br>**DBR-R100-W4800**<br>26.5W x 13D x 5H|
||10<br>30.0<br>**DBR-R063-W1600**<br>12W x 13D x 5H<br>**DBR-R063-W6000**<br>26.5W x 16D x 5H|
||15<br>30.0<br>**DBR-R042-W2400**<br>19W x 10D x 5H<br>**DBR-R042-W9000**<br>28W x 10D x 10H|
||20<br>30.0<br>**DBR-R030-W3200**<br>19W x 13D x 5H<br>**DBR-R030-W012K**<br>28W x 13D x 10H|
||25<br>30.0<br>**DBR-R030-W4000**<br>19W x 16D x 5H<br>**DBR-R030-W015K**<br>28W x 16D x 10H|
||30<br>18.0<br>**DBR-R020-W4800**<br>26.5W x 13D x 5H<br>**DBR-R020-W020K**<br>30W x 18D x 16H|
||40<br>18.0<br>**DBR-R030-W6000**<br>26.5W x 16D x 5H<br>**DBR-R184-W025K**<br>30W x 18D x 16H|
||50<br>9.0<br>**DBR-R013-W7500**<br>26.5W x 16D x 5H<br>**DBR-R012-W030K**<br>30W x 18D x 24H|
||60<br>9.0<br>**DBR-R010-W9000**<br>28W x 10D x 10H<br>**DBR-R010-W036K**<br>30W x 18D x 24H|
||75<br>9.0<br>**DBR-R009-W012K**<br>28W x 13D x 10H<br>**DBR-R009-W045K**<br>30W x 18D x 24H|
||100<br>7.0<br>**DBR-R013-W015K**<br>28W x 16D x 10H<br>**DBR-R8D4-W060K**<br>30W x 18D x 40H|
||125<br>7.0<br>**DBR-R8D2-W020K**<br>30W x 18D x 10H<br>**DBR-R007-W070K**<br>30W x 18D x 40H|
||150<br>7.0<br>**DBR-R007-W025K**<br>30W x 18D x 16H<br>**DBR-R006-W085K**<br>30W x 18D x 56H|
||175<br>7.0<br>**DBR-R007-W030K**<br>30W x 18D x 24H<br>**DBR-R007-W100K**<br>30W x 18D x 72H|
||200<br>2.5<br>**DBR-R3D3-W030K**<br>30W x 18D x 24H<br>**DBR-R2D6-W110K**<br>30W x 18D x 64H|
||250<br>2.5<br>**DBR-R2D5-W036K**<br>30W x 18D x 24H<br>**DBR-R003-W140K**<br>30W x 18D x 72H|
||300<br>2.5<br>**DBR-R3D3-W045K**<br>30W x 18D x 32H<br>1<br>—|
||400<br>1.7<br>**DBR-R002-W060K**<br>30W x 18D x 48H<br>1<br>—|
||450<br>1.7<br>**DBR-R1D8-W070K**<br>30W x 18D x 48H<br>1<br>—|
||500<br>1.7<br>**DBR-R002-W080K**<br>30W x 18D x 56H<br>1<br>—|
|||
## _**Note**_
> 1 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-60**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Replacement Parts**
## **FR4 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|NEMA Type 12 control fan1|1<br>**PP01086**<br>**PP01086**<br>**—**|
|Control module2|SVX control module|1<br>**CSBS0000000000**<br>**CSBS0000000000**<br>**—**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**—**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**—**|
|Converter|Power board3|1<br>**VB00308-0004-2**<br>**VB00208-0003-5**<br>**—**|
|||1<br>**VB00308-0007-2**<br>**VB00208-0004-5**<br>**—**|
|||1<br>**VB00308-0008-2**<br>**VB00208-0005-5**<br>**—**|
|||1<br>**—**<br>**VB00208-0007-5**<br>**—**|
|||1<br>**—**<br>**VB00208-0009-5**<br>**—**|
|||1<br>**—**<br>**VB00410-0012-5-ARV**<br>**—**|
|Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**—**|
|Main fan2|DC fan (main)|1<br>**PP01060**<br>**PP01060**<br>**—**|
|Other|Mounting kit, fixing kit|1<br>**FR00040**<br>**FR00040**<br>**—**|
||Mounting kit, fixing kit, N121|1<br>**FR00079**<br>**FR00079**<br>**—**|
||Control cover, plastic, N1|1<br>**FR00006**<br>**FR00006**<br>**—**|
**2**
## **FR5 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|NEMA Type 12 control fan1|1<br>**PP01088**<br>**PP01088**<br>**—**|
|Control module2|SVX control module|1<br>**CSBS0000000000**<br>**CSBS0000000000**<br>**—**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**—**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**—**|
|Converter|Power board3|1<br>**VB00313-0017-2**<br>**VB00213-0016-5**<br>**—**|
|||1<br>**VB00313-0025-2**<br>**VB00213-0022-5**<br>**—**|
|||1<br>**VB00313-0031-2**<br>**VB00213-0031-5**<br>**—**|
|Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**—**|
|Main fan2|DC fan (main)|1<br>**PP01061**<br>**PP01061**<br>**—**|
|Other|Mounting kit, fixing kit|1<br>**FR00050**<br>**FR00050**<br>**—**|
||Mounting kit, fixing kit, N121|1<br>**FR00081**<br>**FR00081**<br>**—**|
||Control cover, plastic, N1|1<br>**FR05011**<br>**FR05011**<br>**—**|
## _**Notes**_
> 1 Only for NEMA Type 12/IP54 Type drives.
- 2 Factory recommended spare parts.
- 3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-61**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **FR6 Spare Parts**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**pe**<br>**Category**|**s**<br>**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|---|
||Control fan|NEMA Type 12 control fan1|1<br>**PP01049**<br>**PP01049**<br>**—**|
||Control module2|SVX control module|1<br>**CSBS0000000000**<br>**CSBS0000000000**<br>**CSBS0000000000**|
|||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**OPTA9**|
|||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**OPTA2**|
||Converter|Power board3|1<br>**VB00316-0048-2**<br>**VB00416-0038-5**<br>**VB00404-0004-6**|
||||1<br>**VB00316-0061-2**<br>**VB00416-0045-5**<br>**VB00404-0005-6**|
||||1<br>**—**<br>**VB00416-0061-5**<br>**VB00404-0007-6**|
||||1<br>**—**<br>**—**<br>**VB00404-0010-6**|
||||1<br>**—**<br>**—**<br>**VB00404-0013-6**|
||||1<br>**—**<br>**—**<br>**VB00404-0018-6**|
||||1<br>**—**<br>**—**<br>**VB00404-0022-6**|
||||1<br>**—**<br>**—**<br>**VB00404-0027-6**|
||||1<br>**—**<br>**—**<br>**VB00404-0034-6**|
||DC section|Bus capacitor|2<br>**—**<br>**—**<br>**S00930**|
||Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
||Main fan2|DC fan (main)|1<br>**PP01062**<br>**PP01062**<br>**—**|
||Other|Mounting kit, fixing kit|1<br>**FR00060**<br>**FR00060**<br>**FR00060**|
|||Mounting kit, fixing kit, N121|1<br>**FR00082**<br>**FR00082**<br>**FR00082**|
|||Control cover, plastic, N1|1<br>**FR06011**<br>**FR06011**<br>**FR06011**|
## **FR7 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|NEMA Type 12 control fan1|1<br>**PP01049**<br>**PP01049**<br>**PP01049**|
|Control module2|SVX control module|1<br>**CSBS0000000000**<br>**CSBS0000000000**<br>**CSBS0000000000**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power board3|1<br>**VB00319-0075-2**<br>**VB00619-0072-5**<br>**VB00419-0041-6**|
|||1<br>**VB00319-0088-2**<br>**VB00619-0087-5**<br>**VB00419-0052-6**|
|||1<br>**VB00319-0114-2**<br>**VB00619-0105-5**<br>**—**|
|DC section|Bus capacitor|2<br>**—**<br>**—**<br>**PP01041**|
|Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main fan2|DC fan (main)|1<br>**PP01063**<br>**PP01063**<br>**PP01063**|
|Other|Mounting kit, fixing kit|1<br>**FR07071**<br>**FR07071**<br>**FR07071**|
||Mounting kit, fixing kit, N121|1<br>**FR07072**<br>**FR07072**<br>**FR07072**|
||Control cover, plastic, N1|1<br>**FR07011**<br>**FR07011**<br>**FR07011**|
## _**Notes**_
> 1 Only for NEMA Type 12/IP54 Type drives.
> 2 Factory recommended spare parts.
> 3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-62**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **FR8 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|NEMA Type 12 control fan1|1<br>**CP01180**<br>**CP01180**<br>**CP01180**|
|Control module2|SVX control module|1<br>**CSBS0000000000**<br>**CSBS0000000000**<br>**CSBS0000000000**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power board3|1<br>**VB00722-0140-2-ANV**<br>**VB00636-0140-4-ANV**<br>**VB00422-0062-5-ANV**|
|||1<br>**VB00722-0170-2-ANV**<br>**VB00636-0168-4-ANV**<br>**VB00422-0080-5-ANV**|
|||1<br>**VB00722-0205-2-ANV**<br>**VB00636-0205-4-ANV**<br>**VB00422-0100-5-ANV**|
||IGBT|2<br>**PP01175**<br>**PP01175**<br>**PP01127**|
|DC section|Bus capacitor|4<br>**S00335**<br>**S00335**<br>**PP01041**|
|Inverter|Diode|3<br>**CP01268**<br>**CP01268**<br>**CP01373**|
||Rectifier board|1<br>**VB00227**<br>**VB00227**<br>**VB00427**|
|Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main AC fan|Fan AC|1<br>**PP01123**<br>**PP01123**<br>**PP01123**|
||Fan fuse|2<br>**PP20202**<br>**PP20202**<br>**PP20202**|
||Starting cap|1<br>**S00734**<br>**S00734**<br>**S00734**|
||Fan driver board AC|1<br>**VB00599**<br>**VB00799**<br>**VB00799**|
||Isolation transformer (fan)|1<br>**S0000113**<br>**S0000113**<br>**S0000113**|
|Main DC fan2|DC fan|1<br>**PP00071**<br>**PP00071**<br>**PP00071**|
||DC power supply|1<br>**S01016**<br>**S01016**<br>**S01016**|
|Other|Front cover, N121|1<br>**FR08079**<br>**FR08079**<br>**FR08079**|
||Conduit plate, N12|1<br>**FR08082**<br>**FR08082**<br>**FR08082**|
||Front cover, N1|1<br>**FR08106**<br>**FR08106**<br>**FR08106**|
**2**
## _**Notes**_
- 1 Only for NEMA Type 12/IP54 Type drives.
- 2 Factory recommended spare parts.
- 3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-63**
Adjustable Frequency Drives
SVX9000 Drives
## 2.5
## **FR9 Spare Parts**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**pe**<br>**Category**|**s**<br>**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|---|
||Control fan|50 mm fan|1<br>**PP09041**<br>**PP09041**<br>**PP09041**|
|||80 mm fan|1<br>**PP01068**<br>**PP01068**<br>**PP01068**|
||Control module1|SVX control module|1<br>**CSBS0000000000**<br>**CSBS0000000000**<br>**CSBS0000000000**|
|||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**OPTA9**|
|||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**OPTA2**|
||Converter|Power module2|1<br>**FR09-0261-2-ANV**<br>**FR09-0261-4-ANV**<br>**FR09-0125-5-ANV**|
||||1<br>**FR09-0300-2-ANV**<br>**FR09-0300-4-ANV**<br>**FR09-0144-5-ANV**|
||||1<br>**—**<br>**—**<br>**FR09-0170-5-ANV**|
|||Driver board|1<br>**S00583**<br>**S00583**<br>**S00583**|
|||Shunt board2|6<br>**—**<br>**VB00535**<br>**VB00537**|
||||6<br>**—**<br>**VB00536**<br>**VB00542**|
||||6<br>**—**<br>**—**<br>**VB00543**|
||DC section|Balancing resistor|3<br>**PP00052**<br>**PP00052**<br>**PP00052**|
|||Bus capacitor|8<br>**S00335**<br>**S00335**<br>**PP01041**|
|||DC busbars DC–|1<br>**FR09043**<br>**FR09043**<br>**FR09043**|
|||DC busbars DC+|1<br>**FR09044**<br>**FR09044**<br>**FR09044**|
|||DC busbars connection|1<br>**FR09045**<br>**FR09045**<br>**FR09045**|
|||DC busbars +/– insulator|1<br>**FR09046**<br>**FR09046**<br>**FR09046**|
|||DC busbars –/con insulator|1<br>**FR09047**<br>**FR09047**<br>**FR09047**|
||Inverter|Rectifier module|1<br>**FR09826**<br>**FR09822**<br>**FR09823**|
|||Diode|3<br>**CP01268**<br>**CP01268**<br>**CP01268**|
|||Rectifier board|1<br>**—**<br>**VB00459**<br>**VB00460**|
||Keypad1|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
||Main AC fan|Fan AC|1<br>**PP01080**<br>**PP01080**<br>**PP01080**|
|||Fan fuse|2<br>**PP20202**<br>**PP20202**<br>**PP20202**|
|||Starting cap|1<br>**S00465**<br>**S00465**<br>**S00465**|
|||Fan driver board AC|1<br>**VB00899**<br>**VB00399**<br>**VB00299**|
|||Isolation transformer (fan)|1<br>**PP09056**<br>**PP09055**<br>**PP09055**|
||Main DC fan1|DC fan|1<br>**PP00072**<br>**PP00072**<br>**PP00072**|
|||DC power supply|1<br>**S01017**<br>**S01017**<br>**S01017**|
||Other|Front cover power|1<br>**FR09012**<br>**FR09012**<br>**FR09012**|
|||Front cover connection|1<br>**FR09013**<br>**FR09013**<br>**FR09013**|
|||Front power conduit|1<br>**FR09014**<br>**FR09014**<br>**FR09014**|
## _**Notes**_
> 1 Factory recommended spare parts.
> 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-64**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **FR10 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control|Fiber board|1<br>**—**<br>**S00451**<br>**S00451**|
||ASIC board|1<br>**—**<br>**S00457**<br>**S00457**|
|Control fan|ASIC fan|1<br>**—**<br>**PP01096**<br>**PP01096**|
|Control module1|SVX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power module2|1<br>**—**<br>**FR10-0385-4-ANV**<br>**FR10-0261-5-ANV**|
|||1<br>**—**<br>**FR10-0460-4-ANV**<br>**FR10-0325-5-ANV**|
|||1<br>**—**<br>**FR10-0520-4-ANV**<br>**FR10-0385-5-ANV**|
|||1<br>**—**<br>**—**<br>**FR10-0416-5-ANV**|
||Driver board|1<br>**—**<br>**S00450**<br>**S00450**|
||Driver adapter board|1<br>**—**<br>**VB00330**<br>**VB00330**|
||Shunt board2|6<br>**—**<br>**VB00497**<br>**VB00510**|
|||6<br>**—**<br>**VB00498**<br>**VB00511**|
|||6<br>**—**<br>**VB00537**<br>**VB00545**|
|Covers|Top cover|1<br>**—**<br>**FR10340**<br>**FR10340**|
||Side cover|2<br>**—**<br>**FR10341**<br>**FR10341**|
|DC section|Balancing resistor|2<br>**—**<br>**PP13027**<br>**PP13028**|
||DC busbars kit (right)|1<br>**—**<br>**S0000005**<br>**S0000005**|
||Bus capacitor|12<br>**—**<br>**S00335**<br>**S00336**|
|Inverter|Rectifier module|1<br>**—**<br>**FR10823**<br>**FR10823**|
||Charging resistor|1<br>**—**<br>**PP00066**<br>**PP00066**|
||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
||Rectifier board|1<br>**—**<br>**S00591**<br>**S00592**|
|Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main AC fan|Fan assembly (left)|1<br>**—**<br>**FR10846**<br>**FR10846**|
||Fan assembly (right)|1<br>**—**<br>**FR10847**<br>**FR10847**|
||Fan AC|2<br>**—**<br>**PP01080**<br>**PP01080**|
||Fan fuse|4<br>**—**<br>**PP20202**<br>**PP20202**|
||Starting cap|2<br>**—**<br>**S00528**<br>**S00528**|
||Fan driver board AC|2<br>**—**<br>**VB00299**<br>**VB00299**|
||Isolation transformer (left)|1<br>**—**<br>**FR10844**<br>**FR10844**|
||Isolation transformer (right)|1<br>**—**<br>**FR10845**<br>**FR10845**|
|Main DC fan1|DC fan|2<br>**—**<br>**PP00072**<br>**PP00072**|
||DC power supply|2<br>**—**<br>**S01017**<br>**S01017**|
**2**
## _**Notes**_
- 1 Factory recommended spare parts.
- 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-65**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **FR11 Spare Parts**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**pe**<br>**Category**|**s**<br>**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|---|
||Control|Fiber board|1<br>**—**<br>**S00451**<br>**S00451**|
|||ASIC board|1<br>**—**<br>**S00457**<br>**S00457**|
||Control fan|ASIC fan|1<br>**—**<br>**PP01096**<br>**PP01096**|
||Control module1|SVX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
|||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
|||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
||Converter|Power module2|1<br>**—**<br>**FR11-0590-4-ANV**<br>**FR11-0460-5-ANV**|
||||1<br>**—**<br>**FR11-0650-4-ANV**<br>**FR11-0502-5-ANV**|
||||1<br>**—**<br>**FR11-0730-4-ANV**<br>**FR11-0590-5-ANV**|
|||Driver board|1<br>**—**<br>**S00452**<br>**S00452**|
|||Driver adapter board|1<br>**—**<br>**VB00330**<br>**VB00330**|
|||Shunt board2|9<br>**—**<br>**VB00513**<br>**VB00512**|
||||9<br>**—**<br>**VB00514**<br>**VB00546**|
||||9<br>**—**<br>**VB00538**<br>**VB00547**|
||Covers|Top cover|1<br>**—**<br>**FR11345**<br>**FR11345**|
||DC section|Balancing resistor|3<br>**—**<br>**PP13027**<br>**PP13027**|
|||DC busbars kit (right)|3<br>**—**<br>**S0000005**<br>**S0000005**|
|||Bus capacitor|18<br>**—**<br>**S00335**<br>**S00335**|
||Inverter|Rectifier module|1<br>**—**<br>**FR10823**<br>**FR10823**|
|||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
|||Rectifier board|1<br>**—**<br>**S00591**<br>**S00591**|
||Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
||Main AC fan|Fan assembly (right)|3<br>**—**<br>**FR10847**<br>**FR10847**|
|||Fan AC|3<br>**—**<br>**PP01080**<br>**PP01080**|
|||Fan fuse|4<br>**—**<br>**PP20202**<br>**PP20202**|
|||Starting cap|3<br>**—**<br>**S00530**<br>**S00530**|
|||Fan driver board AC|3<br>**—**<br>**VB00299**<br>**VB00299**|
|||Isolation transformer (right)|3<br>**—**<br>**FR10845**<br>**FR10845**|
||Main DC fan1|DC fan|2<br>**—**<br>**PP00072**<br>**PP00072**|
|||DC power supply|2<br>**—**<br>**S01017**<br>**S01017**|
## _**Notes**_
> 1 Factory recommended spare parts.
- 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-66**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **FR12 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control|Fiber board|2<br>**—**<br>**S00451**<br>**S00451**|
||ASIC board|2<br>**—**<br>**S00457**<br>**S00457**|
||Star coupler|1<br>**—**<br>**S00593**<br>**S00593**|
|Control fan|ASIC fan|2<br>**—**<br>**PP01096**<br>**PP01096**|
|Control module1|SVX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power module2|1<br>**—**<br>**FR12-0820-4-ANV**<br>**FR12-0650-5-ANV**|
|||1<br>**—**<br>**FR12-0920-4-ANV**<br>**FR12-0750-5-ANV**|
|||1<br>**—**<br>**FR12-1030-4-ANV**<br>**FR12-0820-5-ANV**|
||Driver board|2<br>**—**<br>**S00450**<br>**S00450**|
||Driver adapter board|2<br>**—**<br>**VB00330**<br>**VB00330**|
||Shunt board|12<br>**—**<br>**VB00498**<br>**VB00511**|
|Covers|Top cover|2<br>**—**<br>**FR10340**<br>**FR10340**|
||Side cover|4<br>**—**<br>**FR10341**<br>**FR10341**|
|DC section|Balancing resistor|4<br>**—**<br>**PP13027**<br>**PP13027**|
||DC busbars kit (right)|2<br>**—**<br>**S0000005**<br>**S0000005**|
||Bus capacitor|24<br>**—**<br>**S00335**<br>**S00336**|
|Inverter|Rectifier module|2<br>**—**<br>**FR10823**<br>**FR10823**|
||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
||Rectifier board|2<br>**—**<br>**S00591**<br>**S00591**|
|Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main AC fan|Fan assembly (left)|2<br>**—**<br>**FR10846**<br>**FR10846**|
||Fan assembly (right)|2<br>**—**<br>**FR10847**<br>**FR10847**|
||Fan AC|4<br>**—**<br>**PP01080**<br>**PP01080**|
||Fan fuse|8<br>**—**<br>**PP20202**<br>**PP20202**|
||Starting cap|4<br>**—**<br>**S00528**<br>**S00528**|
||Fan driver board AC|4<br>**—**<br>**VB00299**<br>**VB00299**|
||Isolation transformer (left)|2<br>**—**<br>**FR10844**<br>**FR10844**|
||Isolation transformer (right)|2<br>**—**<br>**FR10845**<br>**FR10845**|
|Main DC fan1|DC fan|4<br>**—**<br>**PP00072**<br>**PP00072**|
||DC power supply|4<br>**—**<br>**S01017**<br>**S01017**|
**2**
## _**Notes**_
- 1 Factory recommended spare parts.
> 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-67**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **FR13 Spare Parts**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**pe**<br>**Category**|**s**<br>**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|---|
||Control|ASIC board|1<br>**—**<br>**S00457**<br>**S00457**|
|||ASIC assembly|1<br>**—**<br>**60S01030**<br>**60S01030**|
||Control fan|ASIC fan|1<br>**—**<br>**PP01096**<br>**PP01096**|
||Control module1|SVX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
|||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
|||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
||Converter|Power module2|3<br>**—**<br>**FI13-1150-4-ANV**<br>**FR13-1030-5-ANV**|
||||3<br>**—**<br>**FI13-1300-4-ANV**<br>**FR13-1180-5-ANV**|
||||3<br>**—**<br>**FI13-1450-4-ANV**<br>**FR13-920-5-ANV**|
|||Driver board|3<br>**—**<br>**S00454**<br>**S00454**|
|||Driver adapter board|2<br>**—**<br>**VB00330**<br>**VB00330**|
|||Shunt board2|18<br>**—**<br>**VB00505**<br>**VB00516**|
||||18<br>**—**<br>**VB00514**<br>**VB00517**|
||||18<br>**—**<br>**VB00541**<br>**VB00547**|
||Covers|Top cover|3<br>**—**<br>**FI10001**<br>**FI10001**|
|||Side cover|3<br>**—**<br>**FI10003**<br>**FI10003**|
||DC section|Balancing resistor|6<br>**—**<br>**PP13034**<br>**PP13034**|
|||Bus capacitor|36<br>**—**<br>**S00335**<br>**S00336**|
|||DC busbars kit|3<br>**—**<br>**FI13329**<br>**FI13329**|
||Inverter|Rectifier module|2<br>**—**<br>**FR10823**<br>**FR10823**|
|||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
|||Rectifier board|2<br>**—**<br>**S00591**<br>**S00591**|
||Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
||Main AC fan|Fan assembly (left)|3<br>**—**<br>**FI13301**<br>**FI13301**|
|||Fan AC|3<br>**—**<br>**PP01080**<br>**PP01080**|
|||Fan fuse|6<br>**—**<br>**PP20202**<br>**PP20202**|
|||Starting cap|3<br>**—**<br>**S00520**<br>**S00520**|
|||Fan driver board AC|3<br>**—**<br>**VB00299**<br>**VB00299**|
|||Isolation transformer|3<br>**—**<br>**PP10057**<br>**PP10057**|
||Main DC fan1|DC fan|4<br>**—**<br>**PP00072**<br>**PP00072**|
|||DC power supply|4<br>**—**<br>**S01017**<br>**S01017**|
## _**Notes**_
> 1 Factory recommended spare parts.
> 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-68**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **FR14 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control|ASIC board|2<br>**—**<br>**S00457**<br>**S00457**|
||Star coupler|1<br>**—**<br>**S00593**<br>**S00593**|
||ASIC assembly|2<br>**—**<br>**60S01030**<br>**60S01030**|
||Star coupler kit|1<br>**—**<br>**FR10860**<br>**FR10860**|
|Control fan|ASIC fan|2<br>**—**<br>**PP01096**<br>**PP01096**|
|Control module1|SVX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power module2|1<br>**—**<br>**FR14-1770-4-ANV**<br>**FR14-1500-5-ANV**|
|||1<br>**—**<br>**FR14-2150-4-ANV**<br>**FR14-1900-5-ANV**|
|||1<br>**—**<br>**FR14-2700-4-ANV**<br>**FR14-2250-5-ANV**|
||Driver board|6<br>**—**<br>**S00454**<br>**S00454**|
||Driver adapter board|2<br>**—**<br>**VB00330**<br>**VB00330**|
||Shunt board2|36<br>**—**<br>**VB00541**<br>**VB00516**|
|||36<br>**—**<br>**—**<br>**VB00517**|
|Covers|Top cover|6<br>**—**<br>**FI10001**<br>**FI10001**|
||Side cover|6<br>**—**<br>**FI10003**<br>**FI10003**|
|DC section|Balancing resistor|6<br>**—**<br>**PP13034**<br>**PP13034**|
||Bus capacitor|72<br>**—**<br>**S00335**<br>**S00336**|
||DC busbars kit|6<br>**—**<br>**FI13329**<br>**FI13329**|
|Inverter|Rectifier module|2<br>**—**<br>**FR10823**<br>**FR10823**|
||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
||Rectifier board|2<br>**—**<br>**S00591**<br>**S00591**|
|Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main AC fan|Fan assembly (left)|6<br>**—**<br>**FI13301**<br>**FI13301**|
||Fan AC|6<br>**—**<br>**PP01080**<br>**PP01080**|
||Fan fuse|12<br>**—**<br>**PP20202**<br>**PP20202**|
||Starting cap|6<br>**—**<br>**S00520**<br>**S00520**|
||Fan driver board AC|6<br>**—**<br>**VB00299**<br>**VB00299**|
||Isolation transformer|6<br>**—**<br>**PP10057**<br>**PP10057**|
|Main DC fan1|DC fan|6<br>**—**<br>**PP00072**<br>**PP00072**|
||DC power supply|6<br>**—**<br>**S01017**<br>**S01017**|
**2**
## _**Notes**_
- 1 Factory recommended spare parts.
> 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-69**
Adjustable Frequency Drives
SVX9000 Drives
## 2.5
## **Technical Data and Specifications**
**2**
## **SVX9000 Drives**
|**Description**<br>**Specification**<br>**Input Ratings**<br>Input voltage (Vin)<br>+10%/–15%<br>Input frequency (fin)<br>50/60 Hz (variation up to 45–66 Hz)<br>Connection to power<br>Once per minute or less (typical operation)<br>High withstand rating<br>100 kAIC<br>**Output Ratings**<br>Output voltage<br>0 to Vin<br>Continuous output current<br>IHrated 100% at 122°F (50°C), FR9 and below<br>ILrated 100% at 104°F (40°C), FR9 and below<br>IH/IL100% at 104°F (40°C), FR10 and above<br>Overload current (IH/IL)<br>150% IH, 110% ILfor 1 min.<br>Output frequency<br>0 to 320 Hz<br>Frequency resolution<br>0.01 Hz<br>Initial output current (IH)<br>250% for 2 seconds<br>**Control Characteristics**<br>Control method<br>Frequency control (V/f)<br>Open loop: Sensorless vector control<br>Closed loop: SPX9000 drives only<br>Switching frequency<br>Frame 4–6<br>Frame 7–12<br>Adjustable with parameter 2.6.9<br>1–16 kHz; default 10 kHz<br>1–10 kHz; default 3.6 kHz<br>Frequency reference<br>Analog input: Resolution 0.1% (10-bit), accuracy ±1% V/Hz<br>Panel reference: Resolution 0.01 Hz<br>Field weakening point<br>30–320 Hz<br>Acceleration time<br>0–3000 sec.<br>Deceleration time<br>0–3000 sec.<br>Braking torque<br>DC brake: 30% x Tn(without brake option)<br>**Ambient Conditions**<br>Ambient operating<br>temperature<br>14°F (–10°C), no frost to 122°F (50°C) IH(FR4–FR9)<br>14°F (–10°C), no frost to 104°F (40°C) IH(FR10 and up)<br>14°F (–10°C), no frost to 104°F (40°C) IL(all frames)<br>Storage temperature<br>–40° to 158°F (–40° to 70°C)<br>Relative humidity<br>0 to 95% RH, noncondensing, non-corrosive,<br>no dripping water<br>Air quality<br>Chemical vapors: IEC 721-3-3, unit in operation, class 3C2;<br>Mechanical particles: IEC 721-3-3, unit in operation, class 3S2<br>Altitude<br>100% load capacity (no derating) up to 3280 ft (1000m);<br>1% derating for each 328 ft (100m) above 3280 ft (1000m);<br>max. 9842 ft (3000m)<br>Vibration<br>EN 50178, EN 60068-2-6; 5 to 50 Hz, displacement amplitude<br>1 mm (peak) at 3 to 15.8 Hz, max. acceleration amplitude<br>1G at 15.8 to 150 Hz<br>Shock<br>EN 50178, EN 60068-2-27 UPS Drop test (for applicable UPS<br>weights) Storage and shipping: max. 15G, 11 ms (in package)<br>Enclosure class<br>NEMA 1/IP21 or NEMA 12/IP54, open chassis/IP20|**Description**<br>**Specification**|
|---|---|
||**Control Connections**|
||Analog input voltage<br>0 to 10V, R = 200 kohms (–10 to 10V joystick control) resolution<br>0.1%; accuracy ±1%|
||Analog input current<br>0(4) to 20 mA; Ri—250 ohms differential|
||Digital inputs (6)<br>Positive or negative logic; 18 to 30 Vdc|
||Auxiliary voltage<br>+24V ±15%, max. 250 mA|
||Output reference voltage<br>+10V +3%, max. load 10 mA|
||Analog output<br>0(4) to 20 mA; RLmax. 500 ohms;<br>resolution 10 bit; accuracy ±2%|
||Digital outputs<br>Open collector output, 50 mA/48V|
||Relay outputs<br>Two programmable Form C relay outputs<br>switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A|
||**Protections**|
||Overcurrent protection<br>Trip limit 4.0 x IHinstantaneously|
||Overvoltage protection<br>Yes|
||Undervoltage protection<br>Yes|
||Earth fault protection<br>In case of earth fault in motor or motor cable, only the<br>frequency converter is protected|
||Input phase supervision<br>Trips if any of the input phases are missing|
||Motor phase supervision<br>Trips if any of the output phases are missing|
||Overtemperature protection<br>Yes|
||Motor overload protection<br>Yes|
||Motor stall protection<br>Yes|
||Motor underload protection<br>Yes|
||Short-circuit protection<br>Yes (+24V and +10V reference voltages)|
||**Standard I/O Specifications**<br>**Description**<br>**Specification**|
||Six–digital input<br>programmable<br>24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V,Ri>5 kohms|
||Two–analog input<br>configurable w/jumpers<br>Voltage: 0–±10V, Ri>200 kohms<br>Current: 0 (4)–20 mA, Ri= 250 ohms|
||Two–digital output<br>programmable<br>Form C relays 250 Vac<br>30 Vdc 2 amp resistive|
||One–analog output<br>programmable<br>configurable w/jumper<br>0–20 mA, RLmax. 500 ohms 10 bits ±2%|
||One digital output<br>programmable<br>Open collector 48 Vdc 50 mA|
|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-70**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Dimensions**
Approximate Dimensions in Inches (mm)
## _**9000X Open Drives**_
**2**
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR4, FR5 and FR6**
|||||**H3**<br>**D1**<br>**D2**<br>EATON<br>W<br><br>H3<br>H2<br>H1<br>D3|EATON<br>W<br><br>H2<br>1|EATON<br>W<br><br>H2<br>1|2<br>1|
|---|---|---|---|---|---|---|---|
||D|||H||||
|||||||||
|**Voltage**<br>**hp (IH)**||**H1**|**H2**|||||
|**FR4**||||||||
|230V<br>3/4–3||12.9<br>(327)|12.3<br>(313)<br>11.5<br>(292)<br>7.5<br>(190)<br>3.0<br>(77)||||4.9<br>(126)<br>5.0<br>(128)<br>3.9<br>(100)<br>0.5 (13)<br>0.3 (7)<br>11.0 (5)<br>3 @ 1.1 (28)|
|480V<br>1–5||||||||
|**FR5**||||||||
|230V<br>5–7-1/2|||16.0<br>(406)<br>15.3<br>(389)<br>8.4<br>(214)<br>3.9<br>(10||||0)<br>5.8<br>(148)<br>5.6<br>(143)<br>3.9<br>(100)<br>0.5 (13)<br>0.3 (7)<br>17.9 (8)<br>2 @ 1.5 (37)<br>1 @ 1.1 (28)|
|**FR6**||||||||
|230V<br>10–15<br>22.0<br>(558)<br>480V<br>20–30<br>575V<br>2–25|||21.3<br>(541)<br>20.4<br>(519)<br>9.3<br>(237)<br>4.2<br>(10||||5)<br>6.5<br>(165)<br>7.6<br>(195)<br>5.8<br>(148)<br>0.6 (15.5)<br>0.4 (9)<br>40.8 (19)<br>3 @ 1.5 (37)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-71**
Adjustable Frequency Drives
SVX9000 Drives
## 2.5
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54 with Flange Kit, FR4, FR5 and FR6**
**2**
|2|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||
||||||||||||
||||||H1<br>H2||||||
||||||||||||
||||||||||||
|H4||||||||||H5<br>D|
||||||||||||
|D2|||||||||||
||||||H3||||||
||||||||||||
|W5<br>|||||H7||||||
|||||**Flange Opening**<br>**FR4 to FR6**||||||W<br>W4|
|||||H||||||H|
|**R4, FR**<br>**1**<br>8|**5 and FR6 with**<br>**W2**<br>**H1**||**Flange Kit**<br>**H2**<br>6|||**H3**<br>**H4**|||**H5**||
|**R4**|||||||||||
|.0 (128)|4.5 (113)<br>13.3 (337)<br>12.8 (325)|||||12.9 (327)<br>1.2 (30)|||0.9 (22)|7.5 (190)<br>3.0 (77)<br>0.3 (7)|
|**R5**|||||||||||
|.6 (143)|4.7 (120)<br>17.0 (434)<br>16.5 (420)|||||16.5 (419)<br>1.4 (36)|||0.7 (18)|8.4 (214)<br>3.9 (100)<br>0.3 (7)|
|**R6**|||||||||||
|.7 (195)|6.7 (170)<br>22.0 (560)<br>21.6 (549)|||||22.0 (558)<br>1.2 (30)|||0.8 (20)|9.3 (237)<br>4.2 (106)<br>0.3 (7)|
|**lange Opening, FR4 to FR6**<br>**3**<br>**W4**<br>**W5**<br>**H6**||||||**H7**<br>**H8**|||**H9**|**Dia. B**<br>0.3 (7)<br>0.3 (7)<br>0.3 (7)|
|**R4**|||||||||||
|.8 (123)<br>4.5 (113)<br>—<br>12.4 (315)||||||12.8 (325)<br>—|||0.2 (5)||
|**R5**|||||||||||
|.3 (135)<br>4.7 (120)<br>—<br>16.2 (410)||||||16.5 (420)<br>—|||0.2 (5)||
|**R6**|||||||||||
|.3 (185)<br>6.7 (170)<br>6.2 (157)<br>21.2 (539)||||||21.6 (549)<br>0.3 (7)|||0.2 (5)||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-72**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR7**
**==> picture [505 x 371] intentionally omitted <==**
**----- Start of picture text -----**<br>
H1<br>H2<br>W2 W1<br>R2 R1 R2<br>Knockouts<br>H3<br>D2<br>D1<br>D3<br>Weight Knockouts at Inches (mm)<br>Voltage hp (IH) H1 H2 H3 D1 D2 D3 W1 W2 R1 Dia. R2 Dia. Lbs (kg) N1 (O.D.)<br>230V 20–30 24.8 (630) 24.2 (614) 23.2 (590) 10.1 (257) 3.0 (77) 7.3 (184) 9.3 (237) 7.5 (190) 0.7 (18) 0.4 (9) 77.2 (35) 3 at 1.5 (37)<br>480V 40–60<br>575V 30–40<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-73**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR8**
**2**
**==> picture [402 x 434] intentionally omitted <==**
**----- Start of picture text -----**<br>
H1<br>H2<br>W1 W2<br>R2<br>R1<br>H3<br>D1<br>Weight<br>Voltage hp (IH) D1 H1 H2 H3 W1 W2 R1 Dia. R2 Dia. Lbs (kg)<br>230V 40–60 13.5 (344) 30.1 (764) 28.8 (732) 28.4 (721) 11.5 (291) 10 (255) 0.7 (18) 0.4 (9) 127 (58)<br>480V 75–125<br>575V 50–75<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-74**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, with Flange Kit, FR7 and FR8**
||H||H4|H4|||H4|H4||H5|Dia||**D2**<br>**Dia. A**<br>W3<br>W1|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|W2<br>W4||||||||||||||
|||||||||||||||
|||||||||||||||
|||||||||||||||
|||||||||||||||
||||||||H1<br>H2|||||||
|||||||||||||||
|D2||||||||||||||
||||||||||||H7|||
||||||||||||D|||
|||||||||||||||
|||||||||||||||
|||||||||||||||
||2|||||||||||**H7**<br>**D1**||
|||||||||||||||
|||||||||||||||
|H12|||H9||||H9|||H10||||
||||||||||||Di|||
|W6<br>W5|||||||**Flange Opening**<br>**FR7/FR8**|||||||
|H13|||||||H|||||||
|||||||||||||||
|**W1**<br><br>||**W2**<br>**W3**||||**W4**|**H1**<br>||**H2**<br>|**H3**<br>**H4**||||
|**R7**||||||||||||||
|.3 (237)<br>||6.8 (175)<br>10.6 (270)<br>10.0 (253)<br>24.9 (652)<br>24.8 (632)<br>24.8 (630)<br>7.4 (189)|||||||||7.4 (189)<br>0.9 (23)|0.8 (20)<br>10.1 (257)<br>4.6 (117)<br>0.3 (6)||
|**R8**||||||||||||||
|1.2 (285)<br>||—<br>14.0 (355)<br>13.0 (330)<br>32.8 (832)<br>—<br>29.3 (745)<br>10.2 (258)|||||||||10.4 (265)<br>1.7 (43)|2.2 (57)<br>13.5 (344)<br>4.3 (110)<br>0.4 (9)||
|**lange O**<br>**W5**<br>||**pening, FR7 and FR8**<br>**W6**<br>**W7**<br>**H8**<br>**H9**<br>**H10**<br>**H11**<br>**H12**|||||||||**H13**<br>**Dia. B**|||
|**R7**||||||||||||||
|.2 (233)<br>||6.9 (175)<br>10.0 (253)<br>24.4 (619)<br>7.4 (189)<br>7.4 (189)<br>1.4 (35)<br>1.3 (32)|||||||||1.0 (25)<br>0.3 (6)|||
|**R8**||||||||||||||
|1.9 (301)<br>||—<br>13.0 (330)<br>31.9 (810)<br>10.2 (258)<br>10.4 (265)<br>—<br>—|||||||||1.3 (33)<br>0.4 (9)|||
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-75**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54 FR9**
**2**
|D1<br>H6<br>W5<br><br>B- B+ /R+ R-<br>W5|H6<br>+ R-|||H4||H3|H3|||W4|W4|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||W3<br>PE||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
||||||H2<br>H1|||||||
|||||||||||||
|||||||||||||
|||||||||||||
||||||||||D|||
|**Voltage**<br>**hp (IH)**|||**W1**|**W2**|**W3**<br>**W4**<br>**H1**|||||||
|30V<br>75–100|||18.9<br>(480)<br>15.7<br>(400)||0.4<br>(9)<br>2.1<br>(54)<br>45.3<br>(1150)|||44.1<br>(1120)<br>0.6<br>(16)<br>7.4<br>(188)<br>14.2<br>(361.5)<br>13.4<br>(340)|||11.2<br>(285)<br>0.8<br>(21)<br>321.9 (146)|
|80V<br>150–200||||||||||||
|75V<br>100–175||||||||||||
## _**Note**_
> 1 Brake resistor terminal box (H6) included when brake chopper ordered.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-76**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR9 with Flange Kit**
**==> picture [505 x 476] intentionally omitted <==**
**----- Start of picture text -----**<br>
H7<br>W5<br>W1<br>Dia.<br>D1<br>D2<br>D3<br>H4 H2 H4<br>H5 H3 H3 H3 H5<br>W4<br>W3 Flange Opening W2<br>FR9<br>W4<br>H6 H1<br>.20 (5)<br>Dia.<br>W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 H6 H7 D1 D2 D3 Dia.<br>20.9 (530) 20.0 (510) 19.1 (485) 7.9 (200) 0.2 (5.5) 51.7 (1312) 45.3 (1150) 16.5 (420) 3.9 (100) 1.4 (35) 0.4 (9) 0.1 (2) 24.9 (362) 13.4 (340) 4.3 (109) 0.8 (21)<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-77**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR10 Freestanding**
**2**
|||||**W5**<br>**W6**<br>**W7**<br>**H1**<br>**H2**<br>**H3**<br>**D1**<br>Dia.<br>W4<br>D2<br>W2<br>D3<br>W3<br>1<br>Operator<br>(Shown with<br>Optional<br>Disconnect)|**W5**<br>**W6**<br>**W7**<br>**H1**<br>**H2**<br>**H3**<br>**D1**<br>Dia.<br>W4<br>D2<br>W2<br>D3<br>W3<br>1<br>Operator<br>(Shown with<br>Optional<br>Disconnect)||W5<br>W7|W5<br>W7|W5<br>W7|W5<br>W7|W5<br>W7|**D5**<br>**D6**<br>**D7**<br>**Dia. 1**<br>**Dia. 2**<br>**Dia. 3**<br>**Weight**<br>**Lbs (kg)**<br>Dia. 3<br>W4<br>D4<br>W2<br>D5<br>D6<br>D7|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||Dia.<br>W4<br>D2<br>3|W6<br>W6|||||W4|
||||||||||||||
||||||||||||||
||||||||||||||
|||||||||||||Dia. 3<br>D4<br>D5<br>D6<br>D|
||||||||Dia. 2<br>1||||||
||||||||||||||
||||||||||||||
|||||||W2|||||||
||||||||||||||
||||||||W3<br>W3<br>W3<br>||||||
||||W|1|||D1||||||
|1<br>H2<br>H3|||||||||||||
||||||||||||||
||||||||||||||
||||||||||||||
||||||(<br>||||||||
||||||||||||||
||||||||||||||
||||||||||||||
|**W1**<br>**W2**||**W3**|**W4**||||**D2**<br>**D3**<br>**D4**||||||
|3.43<br>595)<br>2.46<br>(62.5)||4.53<br>(115)|0.79<br>(20)|5.95<br>(151)<br>2.95<br>(75)<br>30.11<br>(79)<br>79.45<br>(2018)<br>74.80<br>(1900)<br>20.18<br>(512.5)<br>23.70<br>(602)|||17.44<br>(443)<br>19.02<br>(483)<br>0.47<br>(12)<br>11.22<br>(285)<br>17.60<br>(447)<br>20.08<br>(510)<br>0.83<br>(21)<br>1.89<br>(48)<br>0.43<br>(11)<br>857<br>(389)||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-78**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm) **FR10 Open Chassis**[1]
**==> picture [505 x 402] intentionally omitted <==**
**----- Start of picture text -----**<br>
H3<br>H5 H4<br>W3<br>W2 W5 W1<br>H7 H6 W4<br>H2<br>H1<br>D1<br>D2<br>D3 D4<br>Weight<br>Voltage hp (IH) W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 H6 H7 D1 D2 D3 D4 Lbs (kg)<br>480V 250–350 19.7 16.7 1.2 2.6 12.8 45.9 44.1 34.6 33.5 0.7 24.7 10.8 19.9 17.9 16.7 16.6 518<br>(500) (425) (30) (67) (325) (1165) (1121) (879) (850) (17) (627) (275) (506) (455) (423) (421) (235)<br>575V 200–300<br>**----- End of picture text -----**<br>
**2**
## _**Note**_
> 1 9000X FR12 is built of two FR10 modules. Please refer to SPX9000 installation manual for mounting instructions.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-79**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
**NEMA Type 1/IP21, FR11 Freestanding Drive**
**2**
**==> picture [505 x 523] intentionally omitted <==**
**----- Start of picture text -----**<br>
W5 W8<br>W6 W6 W6 W7 W7W6 W6 W6<br>W4<br>Dia. 3<br>Dia. 1 Dia. 2<br>D3 D5<br>D2 D4<br>W2<br>W3 W3 W3 W3 W2<br>W1 D1<br>H1<br>H2<br>Operator<br>(Shown with<br>Optional<br>Disconnect)<br>H3<br>Weight<br>Voltage hp (IH) W1 W2 W3 W4 W5 W6 W7 W8 H1 H2 H3 D1 D2 D3 D4 D5 Dia. 1 Dia. 2 Dia. 3 Lbs (kg)<br>480 400–550 31.26 2.40 6.50 0.79 3.43 2.95 2.52 1.18 79.45 74.80 20.18 23.70 11.22 19.09 0.47 17.60 0.83 1.89 0.35 x 0.43 526<br>(794) (61) (165) (20) (87) (75) (64) (30) (2018) (1900) (512.5) (602) (285) (485) (12) (447) (21) (48) (9 x 11) (239)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-80**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm) **FR11 Open Chassis**
**==> picture [376 x 528] intentionally omitted <==**
**----- Start of picture text -----**<br>
H2<br>W3 W3<br>W2 W2<br>W2 W2<br>Shown without<br>terminal cover<br>H1<br>W1<br>D2 D1<br>Weight<br>Voltage hp (IH) W1 W2 W3 H1 H2 D1 D2 Lbs (kg)<br>480V 400–550 27.9 (709) 8.86 (225) 2.6 (67) 45.5 (1155) 33.5 (850) 19.8 (503) 18.4 (468) 833 (378)<br>575V 400–500<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-81**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **FR13, Open Chassis Inverter**
**2**
**==> picture [505 x 443] intentionally omitted <==**
**----- Start of picture text -----**<br>
W3<br>D6<br>Dia. 4<br>D8<br>D7<br>D5 [D6]<br>W4 W4 W4 W4 W4 Dia. 1<br>D1 D2 W1<br>H3 H1 H4<br>H2<br>Dia. 3<br>Dia. 2 W2 W2 W2 W2 D4 H5<br>D4<br>Dia. 3<br>D3<br>W5 W5 W5<br>Dia. Dia. Dia. Dia. Weight<br>W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 D1 D2 D3 D4 D5 D6 D7 D8 1 2 3 4 Lbs (kg)<br>27.87 5.91 26.65 4.57 3.35 41.54 2.46 39.86 41.34 0.79 21.77 0.51 0.63 1.97 1.06 1.57 5.91 9.64 0.35x0.59 0.18 0.51 0.37 683<br>(708) (150) (677) (116) (85) (1055) (62.5) (1012.5) (1050) (20) (553) (13) (16) (50) (27) (40) (150) (244.8) (9x15) (4.6) (13) (9.5) (310)<br>Notes<br>**----- End of picture text -----**<br>
9000X FR14 is built of two FR13 modules. Please refer to SPX9000 installation manual for mounting instructions. FR13 is built from an inverter module and a converter module. Please refer to SPX9000 installation manual for mounting instructions.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-82**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **FR13, Open Chassis Converter**
**==> picture [505 x 450] intentionally omitted <==**
**----- Start of picture text -----**<br>
W3 Dia. 3<br>D9<br>D8<br>D7<br>D6<br>Dia. 1 W4 W4 W4<br>D1 D2 W1<br>H3 H1 H4<br>H2<br>D4<br>W2 W2 D5 D5 H5<br>Dia. 2<br>Dia. 2<br>D3<br>W5 W5<br>Weight<br>W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 D1 D2 D3 D4 D5 D6 D7 D8 D9 Dia. 1 Dia. 2 Dia. 3 Lbs (kg)<br>18.74 5.91 17.52 4.57 3.35 41.54 2.46 39.86 41.34 0.69 14.69 0.51 0.73 6.42 2.56 1.06 1.57 5.91 5.24 0.35x0.59 0.51 0.37 295<br>(476) (150) (445) (116) (85) (1055) (62.5) (1012.5) (1050) (17.5) (373) (13) (18.5) (163) (65) (27) (40) (150) (133) (9x15) (13) (9.5) (134)<br>**----- End of picture text -----**<br>
**2**
## **Number of Input Units**
|**480V**<br>**Catalog Number**<br>**hp**<br>**Input**<br>**Modules**<br>**SPX800A0-4A2N1**<br>800<br>2|**690V**<br>**Catalog Number**<br>**hp**<br>**Input**<br>**Modules**<br>**SPX800A0-5A2N1**<br>800<br>2<br>**SPX900A0-5A2N1**<br>900<br>2<br>**SPXH10A0-5A2N1**<br>1000<br>2|
|---|---|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-83**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
**FR13, Open Chassis Converter—900/1000 hp 480V**
**2**
**==> picture [505 x 450] intentionally omitted <==**
**----- Start of picture text -----**<br>
W3 Dia. 4<br>D9<br>D8<br>D7<br>D6<br>Dia. 1 W4 W4 W4 W4 W4<br>D1 D2 W1<br>H3 H1 H4<br>H2<br>D4<br>Dia. 2 W2 W2 W2 W2 D5 D5 H5<br>Dia. 3<br>D3<br>W5 W5 W5<br>Dia. Dia. Dia. Dia. Weight<br>W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 D1 D2 D3 D4 D5 D6 D7 D8 D9 1 2 3 4 Lbs (kg)<br>27.87 5.91 26.65 4.57 3.35 41.54 2.46 39.86 41.34 0.69 14.69 0.51 0.73 6.42 2.56 1.06 1.57 5.91 5.24 0.35x0.59 0.18 0.51 0.37 443<br>(708) (150) (677) (116) (85) (1055) (62.5) (1012.5) (1050) (17.5) (373) (13) (18.5) (163) (65) (27) (40) (150) (133) (9x15) (4.6) (13) (9.5) (201)<br>**----- End of picture text -----**<br>
## **Number of Input Units**
|**480V**<br>**Catalog Number**|**hp**|**Input**<br>**Modules**|
|---|---|---|
|**SPX900A0-4A2N1**<br>**SPXH10A0-4A2N1**|900<br>1000|3<br>3|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-84**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## _**AC Choke Dimensions**_
**2**
## **Choke Types**
|**hoke Types**||||
|---|---|---|---|
|**atalog Number**<br>**Frame Size**|**Choke Type**1<br>CHK0400<br>CHK0520<br>CHK0520<br>2 x CHK0400<br>2 x CHK0400<br>2 x CHK0400<br>2 x CHK0520<br>2 x CHK0520<br>2 x CHK0520<br>2 x CHK0400<br>3 x CHK0520<br>3 x CHK0520<br>4 x CHK0520<br>6 x CHK0400|**Catalog Number**<br>**Frame Size**|**Choke Type**1|
|**oltage Range 380–500V**||**Voltage Range 525–690V**||
|**PX 250 4**<br>FR10<br>**PX 300 4**<br>**PX 350 4**||**SPX 200 5**<br>FR10<br>**SPX 250 5**<br>**SPX 300 5**|CHK0261|
||||CHK0400|
||||CHK0400|
|**PX 400 4**<br>FR11<br>**PX 500 4**<br>**PX 550 4**||**SPX 400 5**<br>FR11<br>**SPX 450 5**<br>**SPX 500 5**|CHK0520|
||||CHK0520|
||||2 x CHK0400|
|**PX 600 4**<br>FR12<br>**PX 650 4**<br>**PX 700 4**||**SPX 550 5**<br>FR12<br>**SPX 600 5**<br>**SPX 700 5**|2 x CHK0400|
||||2 x CHK0400|
||||2 x CHK0400|
|**PX 800 4**<br>FR13<br>**PX 900 4**<br>**PX H10 4**||**SPX 800 5**<br>FR13<br>**SPX 900 5**<br>**SPX H10 5**|2 x CHK0400|
||||2 x CHK0400|
||||2 x CHK0400|
|**PX H12 4**<br>FR14<br>**PX H16 4**||**SPX H13 5**<br>FR14<br>**SPX H15 5**|4 x CHK0400|
||||6 x CHK0400|
## **CHK0520**
**==> picture [343 x 245] intentionally omitted <==**
**----- Start of picture text -----**<br>
6.50 6.50<br>(165) (165) .24<br>(6)<br>8.03 (204)<br>1.69 19.57<br>(43) (497)<br>1 1 1<br>.79 17.57<br>(20) 15.71 (446)<br>1.58 (399)<br>3.03 (40)<br>(77) 3 3 3<br>.83<br>(21) .79<br>(20)<br>2 2 2<br>5.70 7.88<br>(145) (200)<br>9.61 (244) .55 (14)<br>**----- End of picture text -----**<br>
## _**Note**_
> 1 Chokes are provided with all FR10–FR14 drives.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-85**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
**CHK0400 2**
**==> picture [108 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
9.37 (238)<br>1.54<br>(39)<br>2.64<br>(67)<br>.75<br>(19)<br>5.51<br>(140)<br>10.30 (262)<br>**----- End of picture text -----**<br>
**==> picture [189 x 237] intentionally omitted <==**
**----- Start of picture text -----**<br>
.24<br>(6)<br>4.72 4.72<br>(120) (120)<br>13.79 (350)<br>1 1 1<br>.59<br>13.94(354) 1.18(15) 15.08(383) 16.58(421)<br>(30)<br>3 3 3<br>.59<br>(15) 2 2 2<br>5.90<br>(150)<br>10.83 (275)<br>**----- End of picture text -----**<br>
## **CHK0261**
**==> picture [117 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
.24<br>(6)<br>4.72 4.72<br>(120) (120)<br>13.79 (350)<br>**----- End of picture text -----**<br>
**==> picture [114 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
8.11 (206)<br>1.54<br>(39)<br>.87<br>(22)<br>4.25<br>.39 (108) .75 (19)<br>(10) Min.<br>9.06 (230)<br>**----- End of picture text -----**<br>
**==> picture [193 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 1 1<br>.59<br>(15)<br>14.06<br>1.18(30) 11.30 12.56(319) (357)<br>(287)<br>3 3 3<br>.59<br>(15) 2 2 2<br>5.90<br>(150)<br>10.83 (275)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-86**
Adjustable Frequency Drives
2.5
SVX9000 Drives
**==> picture [73 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
SVX9000 Enclosed Drives<br>**----- End of picture text -----**<br>
## **Contents**
|**Contents**||**2**|
|---|---|---|
|**_Description_**|**_Page_**||
|SVX9000 Drives . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-48**|**2**|
|SVX9000 Enclosed Drives|||
|Product Identification . . . . . . . . . . . . . . . . . . . .|**V6-T2-88**|**2**|
|Catalog Number Selection . . . . . . . . . . . . . . . .<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-89**<br>**V6-T2-90**|**2**|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V6-T2-94**<br>**V6-T2-98**|**2**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>SVX9000 VFD Pump Panels . . . . . . . . . . . . . . . . .|**V6-T2-100**<br>**V6-T2-111**|**2**|
## **SVX9000 Enclosed Drives**
## **Product Description**
- **Standard Enclosed—** covers a wide range of the most commonly ordered options. Pre-engineering eliminates the lead time normally associated with customer specific options.
- **Modified Standard Enclosed** —applies to specific customer requirements that vary from the standard enclosed offering, such as the need for an additional indicating light or minor modifications to drawings. _Consult your Eaton representative for assistance in pricing and lead time._
- **Custom Engineered** — for those applications with more unique or complex requirements, these are individually engineered to the customer’s needs. _Consult your Eaton representative for assistance in pricing and lead time._
## **Features**
- NEMA Type 1/IP21 or NEMA Type 12/IP54 enclosures
- Input voltage: 208V, 230V, 480V and 575V (consult factory)
- Complete range of control, network and power options
- Horsepower range:
- 208V—3/4 to 100 hp IH; 1 to 100 hp IL
- 230V—3/4 to 100 hp IH; 1 to 100 hp IL
- 480V—1 to 700 hp IH; 1-1/2 to 800 hp IL
- Padlockable disconnect
## **Standards and Certifications**
- UL Listed
- cUL Listed
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-87**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Product Identification**
**2**
## **Enclosed 9000X Series Drive**
**==> picture [316 x 284] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 2 3<br>4<br>a \ a >, Snonn\ ore \<br>5<br>6<br>Amel<br> i, at ” “ . M } - ay ==4 K N a<br>7<br>12 11 10 9 8<br>6 Output contactor 9 115V control transformer<br>• Option PE (included as • Option KB<br> standard with bypass option) 10 Bypass pilot lights and selector switches<br>7 Bypass contactor • Option RA<br>• Option RA • Option RB<br>**----- End of picture text -----**<br>
- 1 Door mounted keypad (included as 6 Output contactor standard with bypass option) • Option PE (included as
- 2 SVX9000 variable frequency drive standard with bypass option)
- 3 Input disconnect • Option P1
- Option RB
- Option L2
- 4 Input line fuses • Option P3 8 Overload relay • Option PH
- 5 Input contactor (included as • Option PI standard with bypass option)
- Option KF
- 11 Customer control and signal connection terminal block
- 12 Control relay
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-88**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Catalog Number Selection**
**SVX9000 Enclosed NEMA Type 1/IP21 and NEMA Type 12/IP54 Drives**
Build Alphabetically and Numerically
**==> picture [473 x 406] intentionally omitted <==**
**----- Start of picture text -----**<br>
SVX F07 1 4 A A _ _ _ _ _ _ _ _ _ _<br>Enclosed Options [145] Type<br>Product Family K1 Door-mounted speed potentiometer [3] Control<br>K2 Door-mounted speed potentiometer with HOA Control<br>SVX = Enclosed drives<br>selector switch [3]<br>K4 HAND/OFF/AUTO switch (22 mm) Control<br>K5 MANUAL/AUTO ref switch (22 mm) Control<br>Horsepower Rating K6 START/STOP pushbuttons (22 mm) Control<br>F07 = 3/4 hp 025 = 25 hp 250 = 250 hp KB 115V control transformer (500 VA) Control<br>001 = 1 hp 030 = 30 hp 300 = 300 hp KF Bypass test switch for RA and RB Addl. bypass<br>F15 = 1-1/2 hp 040 = 40 hp 350 = 350 hp KO Standard elapsed time meter Control<br>002 = 2 hp 050 = 50 hp 400 = 400 hp L1 POWER ON, RUN and FAULT pilot lights Light<br>003 = 3 hp 060 = 60 hp 500 = 500 hp L2 Bypass pilot lights for RA, RB bypass options Addl. bypass<br>005 = 5 hp 075 = 75 hp 550 = 550 hp LA Green RUN light (22 mm) Light<br>007 = 7-1/2 hp 100 = 100 hp 600 = 600 hp LD Green STOP light (22 mm) Light<br>010 = 10 hp 125 = 125 hp 650 = 650 hp LE Red RUN light Light<br>015 = 15 hp 150 = 150 hp 700 = 700 hp LF Red STOP light (22 mm) Light<br>020 = 20 hp 200 = 200 hp 800 = 800 hp LJ White POWER ON light (22 mm) Light<br>LU Misc. light (22 mm) Light<br>P1 Input circuit breaker Input<br>Enclosure Rating P3 Input line fuses (200 kAIC) Input<br>1 = NEMA Type 1/IP21 P8 SPD (50 kA per phase) Input<br>2 = NEMA Type 12/IP54 PA SPD (100 kA per phase) Input<br>6 = NEMA Type 12/IP54 filtered PE Output contactor Output<br>PF Output filter (100–300 ft) Output<br>PG MotoRx (300–600 ft) 1000 V/μS DV/DT filter Output<br>Voltage Ratin g PH Single overload relay Output<br>1 = 208V PI Dual overload relays Output<br>2 = 230V PN Dual overloads for bypass Addl. bypass<br>4 = 480V RA Manual HOA bypass controller Bypass<br>RB Manual IOB bypass controller Bypass<br>RC Auto transfer HOA bypass controller Bypass<br>RD Auto transfer IOB bypass controller Bypass<br>Application—Torque/Braking [2]<br>S5 Floor stand 22 in Enclosure<br>A = IL/no brake chopper S6 Floor stand 12 in Enclosure<br>B = IL/internal brake chopper S7 10 in expansion Enclosure<br>D = IH/no brake chopper S8 20 in expansion Enclosure<br>E = IH/internal brake chopper S9 Space heater Enclosure<br>SA Space heater with CPT Enclosure<br>Enclosed Styl e<br>Communication Options [6]<br>A = Enclosed drive<br>C2 = Modbus C6 = CANopen (slave) CI = Modbus TCP<br>C3 = PROFIBUS DP C7 = DeviceNet CJ = BACnet<br>C4 = LonWorks C8 = Modbus (D9 type CQ = EtherNet/IP<br>C5 = PROFIBUS DP connector) C3 = RS-232 with D9<br>(D9 connector) CA = Johnson Controls N2 connection<br>**----- End of picture text -----**<br>
|**Enclosed Options**145|**Enclosed Options**145|**Enclosed Options**145|**Enclosed Options**145|**Enclosed Options**145|**Enclosed Options**145|**Enclosed Options**145|**Type**|
|---|---|---|---|---|---|---|---|
|**K1**<br>**K2**<br>**K4**<br>**K5**<br>**K6**<br>**KB**<br>**KF**<br>**KO**|Door-mounted speed potentiometer3<br>Door-mounted speed potentiometer with HOA<br>selector switch3<br>HAND/OFF/AUTO switch (22 mm)<br>MANUAL/AUTO ref switch (22 mm)<br>START/STOP pushbuttons (22 mm)<br>115V control transformer (500 VA)<br>Bypass test switch for RA and RB<br>Standard elapsed time meter||||||Control<br>Control<br>Control<br>Control<br>Control<br>Control<br>Addl. bypass<br>Control|
|**L1**<br>**L2**<br>**LA**<br>**LD**<br>**LE**<br>**LF**<br>**LJ**<br>**LU**|POWER ON, RUN and FAULT pilot lights<br>Bypass pilot lights for RA, RB bypass options<br>Green RUN light (22 mm)<br>Green STOP light (22 mm)<br>Red RUN light<br>Red STOP light (22 mm)<br>White POWER ON light (22 mm)<br>Misc. light (22 mm)||||||Light<br>Addl. bypass<br>Light<br>Light<br>Light<br>Light<br>Light<br>Light|
|**P1**<br>**P3**<br>**P8**<br>**PA**<br>**PE**<br>**PF**<br>**PG**<br>**PH**<br>**PI**<br>**PN**|Input circuit breaker<br>Input line fuses (200 kAIC)<br>SPD (50 kA per phase)<br>SPD (100 kA per phase)<br>Output contactor<br>Output filter (100–300 ft)<br>MotoRx (300–600 ft) 1000 V/μS DV/DT filter<br>Single overload relay<br>Dual overload relays<br>Dual overloads for bypass||||||Input<br>Input<br>Input<br>Input<br>Output<br>Output<br>Output<br>Output<br>Output<br>Addl. bypass|
|**RA**<br>**RB**<br>**RC**<br>**RD**|Manual HOA bypass controller<br>Manual IOB bypass controller<br>Auto transfer HOA bypass controller<br>Auto transfer IOB bypass controller||||||Bypass<br>Bypass<br>Bypass<br>Bypass|
|**S5**<br>**S6**<br>**S7**<br>**S8**<br>**S9**<br>**SA**|Floor stand 22 in<br>Floor stand 12 in<br>10 in expansion<br>20 in expansion<br>Space heater<br>Space heater with CPT||||||Enclosure<br>Enclosure<br>Enclosure<br>Enclosure<br>Enclosure<br>Enclosure|
|||||||||
||||**Communication Options**6|||||
|**C2**= Mod<br>**C3**= PRO<br>**C4**= Lon<br>**C5**= PROF<br>(D9 c|||bus<br>FIBUS DP<br>Works<br>IBUS DP<br>onnector)|**C6**= CANopen (slave)<br>**C7**= DeviceNet<br>**C8**= Modbus (D9 type<br>connector)<br>**CA**= Johnson Controls N2||**CI**= Modbus TCP<br>**CJ**= BACnet<br>**CQ**= EtherNet/IP<br>**C3**= RS-232 with D9<br>connection||
|||||||||
||||**Control Options**|||||
|**B1**= 6 DI,<br>**B2**= 1 RO<br>**B4**= 1 AI<br>1 ext|||1 ext +24 Vdc/EXT +24 Vdc<br>(NC-NO), 1 RO (NO), 1 therm<br>(mA isolated), 2 AO (mA isolated),<br>+24 Vdc/EXT +24 Vdc||**B5**= 3 RO (NO)<br>**B8**= 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>**B9**= 1 RO (NO), 5 DI 42–240 Vac input|||
|||||||||
|**Engineered Options**||||||||
|**VB**||Varnished boards||||||
**2**
## _**Notes**_
- 1 Local/remote keypad is included as the standard control panel.
- 2 Brake chopper is a factory installed option only, see drive options on **Page V6-T2-49** . External dynamic braking resistors not included. Consult factory.
- 3 Includes local/remote speed reference switch.
- 4 Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
- 5 See **Pages V6-T2-96** and **V6-T2-97** for descriptions.
- 6 See **Pages V6-T2-94** and **V6-T2-95** for complete descriptions.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-89**
2.5
SVX9000 Drives
## Adjustable Frequency Drives
## **Product Selection**
## _**When Ordering**_
- **2** ●
- ~~_~~ Select a base catalog number that meets the
- **2** application requirements— nominal horsepower,
- **2** voltage and enclosure rating (the enclosed drive’s
- **2** continuous output amp rating should be equal to or
greater than the motor’s full load amp rating). The base enclosed package includes a standard drive, door mounted local/remote keypad and enclosure.
- If dynamic brake chopper or control/communication option is desired, change the appropriate code in the base catalog number.
- Select enclosed options. Add the codes as suffixes to the base catalog number in alphabetical and numeric order.
- **Read all footnotes** .
## _**208V Drives**_
## **Input Base Drives**
**SVX9000 Enclosed**
**Drives**
|**SVX9000 Enclosed**<br>**Drives**|**Input Base Drives**|**Input Base Drives**|**Input Base Drives**|||||
|---|---|---|---|---|---|---|---|
|**Drives**||||**NEMA Type 1/IP21**||**NEMA Type 12/IP54**||
|**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>3/4<br>3.7<br>4<br>**SVXF0711EA**<br>4<br>**SVXF0721EA**<br>~~a~~||||||||
|||1|4.8||**SVX00111EA**||**SVX00121EA**|
|||1-1/2|6.6||**SVXF1511EA**||**SVXF1521EA**|
|||2|7.8||**SVX00211EA**||**SVX00221EA**|
|||3|11||**SVX00311EA**||**SVX00321EA**|
|||5|17.5|5|**SVX00511EA**|5|**SVX00521EA**|
||1|7-1/2<br>10|25<br>31|6|**SVX00711EA**<br>**SVX01011EA**|6|**SVX00721EA**<br>**SVX01021EA**|
||2|15<br>20|48<br>61|7|**SVX01511EA**<br>**SVX02011DA**|7|**SVX01521EA**<br>**SVX02021DA**|
|||25|75||**SVX02511DA**||**SVX02521DA**|
|||30|88||**SVX03011DA**||**SVX03021DA**|
||3|40|114|8|**SVX04011DA**|8|**SVX04021DA**|
||4|50|143|8|**SVX05011DA**|8|**SVX05021DA**|
||5|60|170|8|**SVX06011DA**|8|**SVX06021DA**|
|||75<br>100|211<br>273|9|**SVX07511DA**<br>**SVX10011DA**|9|**SVX07521DA**<br>**SVX10021DA**|
||**Low Overload Drive and Enclosure**<br>0<br>1||**Low Overload Drive and Enclosure**<br>4.8<br>4||**SVX00111BA**|4|**SVX00121BA**|
|||1-1/2|6.6||**SVXF1511BA**||**SVXF1521BA**|
|||2|7.8||**SVX00211BA**||**SVX00221BA**|
|||3|11||**SVX00311BA**||**SVX00321BA**|
|||5|17.5|5|**SVX00511BA**|5|**SVX00521BA**|
|||7-1/2|25||**SVX00711BA**||**SVX00721BA**|
||1|10<br>15|31<br>48|6|**SVX01011BA**<br>**SVX01511BA**|6|**SVX01021BA**<br>**SVX01521BA**|
||2|20<br>25|61<br>75|7|**SVX02011BA**<br>**SVX02511AA**|7|**SVX02021BA**<br>**SVX02521AA**|
|||30|88||**SVX03011AA**||**SVX03021AA**|
|||40|114||**SVX04011AA**||**SVX04021AA**|
||3|50|—|8|**SVX05011AA**|8|**SVX05021AA**|
||4|60|170|8|**SVX06011AA**|8|**SVX06021AA**|
||5|753|205|8|**SVX07511AA**|8|**SVX07521AA**|
|||1003|261|9|**SVX10011AA**|9|**SVX10021AA**|
## _**Notes**_
For brake chopper options, see **Page V6-T2-58** .
- 1 See enclosure dimensions starting on **Page V6-T2-100** .
- 2 Includes drive, local/remote keypad and enclosure.
- 3 These units are current rated (75 IL hp 205 amps, 100 IL hp 261 amps). They do not meet NEC ampere ratings.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-90**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**230V Drives**_
## **Input Base Drives**
|**SVX9000 Enclosed**|**SVX9000 Enclosed**|**Input Base Drives**|**Input Base Drives**|**Input Base Drives**|||||
|---|---|---|---|---|---|---|---|---|
|**Drives**|||||**NEMA Type 1/IP21**||**NEMA Type 12/IP54**||
|||**Enclosure**|||**Frame**|**Base Catalog**|**Frame**|**Base Catalog**|
|||**Size**1|**hp**|**Current (A)**|**Size**|**Number**2|**Size**|**Number**2|
|||**High Overload Drive and Enclosure**|||||||
|||0|3/4|3.7|4|**SVXF0712EA**|4|**SVXF0722EA**|
||||1|4.8||**SVX00112EA**||**SVX00122EA**|
||||1-1/2|6.6||**SVXF1512EA**||**SVXF1522EA**|
||||2|7.8||**SVX00212EA**||**SVX00222EA**|
||||3|11||**SVX00312EA**||**SVX00322EA**|
||||5|17.5|5|**SVX00512EA**|5|**SVX00522EA**|
||||7-1/2|25||**SVX00712EA**||**SVX00722EA**|
|||1|10|31|6|**SVX01012EA**|6|**SVX01022EA**|
||||15|48||**SVX01512EA**||**SVX01522EA**|
|||2|20|61|7|**SVX02012DA**|7|**SVX02022DA**|
||||25|75||**SVX02512DA**||**SVX02522DA**|
||||30|88||**SVX03012DA**||**SVX03022DA**|
|||3|40|114|8|**SVX04012DA**|8|**SVX04022DA**|
|||4|50|140|8|**SVX05012DA**|8|**SVX05022DA**|
|||5|60|170|8|**SVX06012DA**|8|**SVX06022DA**|
||||75|205|9|**SVX07512DA**|9|**SVX07522DA**|
||||1003|261||**SVX10012DA**||**SVX10022DA**|
|||**Low Overload Drive and Enclosure**|||||||
|||0|1|4.8|4|**SVX00112BA**|4|**SVX00122BA**|
||||1-1/2|6.6||**SVXF1512BA**||**SVXF1522BA**|
||||2|7.8||**SVX00212BA**||**SVX00222BA**|
||||3|11||**SVX00312BA**||**SVX00322BA**|
||||5|17.5|5|**SVX00512BA**|5|**SVX00522BA**|
||||7-1/2|25||**SVX00712BA**||**SVX00722BA**|
||||10|31||**SVX01012BA**||**SVX01022BA**|
|||1|15|48|6|**SVX01512BA**|6|**SVX01522BA**|
||||20|61||**SVX02012BA**||**SVX02022BA**|
|||2|25|75|7|**SVX02512AA**|7|**SVX02522AA**|
||||30|88||**SVX03012AA**||**SVX03022AA**|
||||40|114||**SVX04012AA**||**SVX04022AA**|
|||3|50|140|8|**SVX05012AA**|8|**SVX05022AA**|
|||4|60|170|8|**SVX06012AA**|8|**SVX06022AA**|
|||5|75|205|8|**SVX07512AA**|8|**SVX07522AA**|
||||1003|261|9|**SVX10012AA**|9|**SVX10022AA**|
**2**
## _**Notes**_
For brake chopper options, see **Page V6-T2-58** . 1 See enclosure dimensions starting on **Page V6-T2-100** . 2 Includes drive, local/remote keypad and enclosure. 3 This unit is current rated (100 IL hp 100 amps, 261 IL hp). It is not hp rated. They do not meet NEC ampere ratings.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-91**
2.5
SVX9000 Drives
## Adjustable Frequency Drives
## _**480V Drives**_
|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|**2**<br>**2**<br>**2**<br>**2**<br>**Input Base Drives**<br>**NEMA Type 1/IP21**<br>**NEMA Type 12/IP54**<br>**Enclosure**<br>**Size**1<br>**hp**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**High Overload Drive and Enclosure**<br>0<br>1<br>2.2<br>4<br>**SVX00114EA**<br>4<br>**SVX00124EA**<br>1-1/2<br>3.3<br>**SVXF1514EA**<br>**SVXF1524EA**<br>2<br>4.3<br>**SVX00214EA**<br>**SVX00224EA**<br>**SVX9000 Enclosed**<br>**Drives**<br>~~_MB~~<br>~~a~~|
|---|---|---|---|---|---|---|---|---|---|
|**2**||||3|5.6||**SVX00314EA**||**SVX00324EA**|
|||||5|7.6||**SVX00514EA**||**SVX00524EA**|
|**2**||||7-1/2|12|5|**SVX00714EA**|5|**SVX00724EA**|
|||||10|16||**SVX01014EA**||**SVX01024EA**|
|**2**||||15|23||**SVX01514EA**||**SVX01524EA**|
|**2**|||1|20<br>25|31<br>38|6|**SVX02014EA**<br>**SVX02514EA**|6|**SVX02024EA**<br>**SVX02524EA**|
|**2**||||30|46||**SVX03014EA**||**SVX03024EA**|
||||2|40|61|7|**SVX04014DA**|7|**SVX04024DA**|
|**2**||||50|72||**SVX05014DA**||**SVX05024DA**|
|||||60|87||**SVX06014DA**||**SVX06024DA**|
|**2**|||3|75|105|8|**SVX07514DA**|8|**SVX07524DA**|
|**2**|||4|100<br>125|140<br>170|8|**SVX10014DA**<br>**SVX12514DA**|8|**SVX10024DA**<br>**SVX12524DA**|
|**2**|||5|150|205|9|**SVX15014DA**|9|**SVX15024DA**|
|||||200|245||**SVX20014DA**||**SVX20024DA**|
|**2**|||6, 834|250|300|10|**SVX25014DA**|10|**SVX25064DA**|
|||||300|385||**SVX30014DA**||**SVX30064DA**|
|**2**||||350|460||**SVX35014DA**||**SVX35064DA**|
|**2**|||8, 945|400|520|11|**SVX40014DA**|11|**SVX40064DA**|
|||||500|590||**SVX50014DA**||**SVX50064DA**|
|**2**||||550|650||**SVX55014DA**||**SVX55064DA**|
||||6|600|730|12|**SVX60014DA**|12|**SVX60064DA**|
|**2**||||650|820||**SVX65014DA**||**SVX65064DA**|
|**2**||||700|920||**SVX70014DA**||**SVX70064DA**|
## _**Notes**_
For brake chopper options, see **Page V6-T2-58** .
- 1 See enclosure dimensions starting on **Page V6-T2-100** .
- 2 Includes drive, local/remote keypad and enclosure.
- 3 The smaller enclosure Size 6 accommodates only power options, input disconnect (P1) and input line fuses (P3). Bypass and other options require Size 8. Adding any standard control option will not require the larger enclosure.
- 4 For other options, consult factory.
- 5 The smaller enclosure Size 8 accommodates only power options, input disconnect (P1) and input line fuses (P3). Bypass and other options require Size 9. Adding any standard control option will not require the larger enclosure.
- 6 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-92**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **SVX9000 Enclosed Input Base Drives, continued Drives Enclosure Size**[1] **hp Current (A) Low Overload Drive and Enclosure** 0 1-1/2 3.3 4 2 4.3 7 3 5.6
|**Enclosure**<br>**Size**[1]<br>**hp**<br>**Low Overload Drive and Enclosure**<br>0<br>1-1/2<br>2<br>3|**Enclosure**<br>**Size**[1]<br>**hp**<br>**Low Overload Drive and Enclosure**<br>0<br>1-1/2<br>2<br>3|**NEMA Type 1/IP21**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Low Overload Drive and Enclosure**<br>3.3<br>4<br>**SVXF1514BA**<br>4.3<br>**SVX00214BA**<br>5.6<br>**SVX00314BA**|**NEMA Type 1/IP21**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Low Overload Drive and Enclosure**<br>3.3<br>4<br>**SVXF1514BA**<br>4.3<br>**SVX00214BA**<br>5.6<br>**SVX00314BA**|**NEMA Type 1/IP21**<br>**Current (A)**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>**Low Overload Drive and Enclosure**<br>3.3<br>4<br>**SVXF1514BA**<br>4.3<br>**SVX00214BA**<br>5.6<br>**SVX00314BA**|**NEMA Type 12/IP54**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>4<br>**SVXF1524BA**<br>**SVX00224BA**<br>**SVX00324BA**|**NEMA Type 12/IP54**<br>**Frame**<br>**Size**<br>**Base Catalog**<br>**Number**2<br>4<br>**SVXF1524BA**<br>**SVX00224BA**<br>**SVX00324BA**|
|---|---|---|---|---|---|---|
||5|7.6||**SVX00514BA**||**SVX00524BA**|
||7-1/2|12||**SVX00714BA**||**SVX00724BA**|
||10|16|5|**SVX01014BA**|5|**SVX01024BA**|
||15|23||**SVX01514BA**||**SVX01524BA**|
||20|31||**SVX02014BA**||**SVX02024BA**|
|1|25|38|6|**SVX02514BA**|6|**SVX02524BA**|
||30|46||**SVX03014BA**||**SVX03024BA**|
||40|61||**SVX04014BA**||**SVX04024BA**|
|2|50|72|7|**SVX05014AA**|7|**SVX05024AA**|
||60|87||**SVX06014AA**||**SVX06024AA**|
||75|105||**SVX07514AA**||**SVX07524AA**|
|3|100|140|8|**SVX10014AA**|8|**SVX10024AA**|
|4|125|170|8|**SVX12514AA**|8|**SVX12524AA**|
||150|205||**SVX15014AA**||**SVX15024AA**|
|5|200|261|9|**SVX20014AA**|9|**SVX20024AA**|
||250|300||**SVX25014AA**||**SVX25024AA**|
|6, 834|300|385|10|**SVX30014AA**|10|**SVX30064AA**|
||350|460||**SVX35014AA**||**SVX35064AA**|
||400|520||**SVX40014AA**||**SVX40064AA**|
|8, 945|500|590|11|**SVX50014AA**|11|**SVX50064AA**|
||550|650||**SVX55014AA**||**SVX55064AA**|
||600|730||**SVX60014AA**||**SVX60064AA**|
|6|650|820|12|**SVX65014AA**|12|**SVX65064AA**|
||700|920||**SVX70014AA**||**SVX70064AA**|
||800|1030||**SVX80014AA**||**SVX80064AA**|
**2**
## _**Notes**_
For brake chopper options, see **Page V6-T2-58** .
- 1 See enclosure dimensions starting on **Page V6-T2-100** .
- 2 Includes drive, local/remote keypad and enclosure.
- 3 The smaller enclosure Size 6 accommodates only power options, input disconnect (P1) and input line fuses (P3). Bypass and other options require Size 8. Adding any standard control option will not require the larger enclosure.
- 4 For other options, consult factory.
- 5 The smaller enclosure Size 8 accommodates only power options, input disconnect (P1) and input line fuses (P3). Bypass and other options require Size 9. Adding any standard control option will not require the larger enclosure.
- 6 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-93**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Options**
## _**9000X Series Option Board Kits**_
**2**
The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is designed to accept a total of five option boards.
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2 relay output board, which are installed in slots A and B.
## **Option Boards**
## **Option Board Kits**
|A<br>B C D E|**Option Kit Description**1<br>**Allowed Slot**<br>**Locations**2<br>**Field**<br>**Installed**<br>**Factory**<br>**Installed**<br>**SVX Ready Programs**<br>**Catalog**<br>**Number**<br>**Option**<br>**Designator**<br>**Basic**<br>**Local/**<br>**Remote**<br>**Standard**<br>**MSS**<br>**PID**<br>**Multi-P.**<br>**PFC**|
|---|---|
||**Standard I/O Cards**|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/EXT +24 Vdc<br>A<br>**OPTA9**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||2 RO (NC-NO)<br>B<br>**OPTA2**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||**Extended I/O Cards**|
||2 RO, therm—SPX only<br>B<br>**OPTA3**<br>**A3**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Encoder low volt +5V/15V/24V—SPX only<br>C<br>**OPTA4**<br>**A4**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Encoder high volt +15V/24V—SPX only<br>C<br>**OPTA5**<br>**A5**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Double encoder—SPX only<br>C<br>**OPTA7**<br>**A7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 DO, 2 AI, 1 AO—SPX only<br>A<br>**OPTA8**<br>**A8**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||3 DI (encoder 10–24V), out +15V/+24V,<br>2 DO (pulse+direction)—SPX only<br>C<br>**OPTAE**<br>**AE**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 ext +24 Vdc/EXT +24 Vdc<br>B, C,**D**, E<br>**OPTB1**<br>**B1**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 RO (NC-NO), 1 RO (NO), 1 therm<br>B, C,**D**, E<br>**OPTB2**<br>**B2**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 AI (mA isolated), 2 AO (mA isolated),<br>1 ext +24 Vdc/EXT +24 Vdc<br>B, C,**D**, E<br>**OPTB4**<br>**B4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||3 RO (NO)<br>B, C,**D**, E<br>**OPTB5**<br>**B5**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>B, C,**D**, E<br>**OPTB8**<br>**B8**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||1 RO (NO), 5 DI 42–240 Vac input<br>B, C,**D**, E<br>**OPTB9**<br>**B9**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||**Communication Cards**|
||Modbus3<br>D,**E**<br>**OPTC2**<br>**C2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Modbus TCP<br>D,**E**<br>**OPTCI**<br>**CI**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||BACnet<br>D,**E**<br>**OPTCJ**<br>**CJ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||EtherNet/IP<br>D,**E**<br>**OPTCQ**<br>**CQ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Johnson Controls N23<br>D,**E**<br>**OPTC2**<br>**CA**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||PROFIBUS DP<br>D,**E**<br>**OPTC3**<br>**C3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||LonWorks<br>D,**E**<br>**OPTC4**<br>**C4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP (D9 connector)<br>D,**E**<br>**OPTC5**<br>**C5**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||CANopen (slave)<br>D,**E**<br>**OPTC6**<br>**C6**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||DeviceNet<br>D,**E**<br>**OPTC7**<br>**C7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Modbus (D9 type connector)<br>D,**E**<br>**OPTC8**<br>**C8**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Adapter—SPX only<br>D,**E**<br>**OPTD1**<br>**D1**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Adapter—SPX only<br>D,**E**<br>**OPTD2**<br>**D2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||RS-232 with D9 connection<br>D,**E**<br>**OPTD3**<br>**D3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
## _**Notes**_
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
- 2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
- 3 OPTC2 is a multi-protocol option card.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-94**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Modbus RTU Network Communications**
The Modbus Network Card OPTC2 is used for connecting the 9000X Drive as a slave on a Modbus network. The interface is connected by a 9-pin DSUB connector (female) and the baud rate ranges from 300 to 19200 baud. Other communication parameters include an address range from 1 to 247; a parity of None, Odd or Even; and the stop bit is 1.
## **PROFIBUS Network Communications**
The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS-DP network. The interface is connected by a 9-pin DSUB connector (female). The baud rates range from 9.6K baud to 12M baud, and the addresses range from 1 to 127.
## **LonWorks Network Communications**
The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network. This interface uses Standard Network Variable Types (SNVT) as data types. The channel connection is achieved using a FTT-10A Free Topology transceiver via a single twisted transfer cable. The communication speed with LonWorks is 78 kBits/s.
## **CANopen (Slave) Communications**
The CANopen (Slave) Network Card OPTC6 is used for connecting the 9000X Drive to a host system. According to ISO11898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms, and specific line delay of nominal 5 nS/m. 120 ohms line termination resistors required for installation.
## **DeviceNet Network Communications**
The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network. It includes a 5.08 mm pluggable connector. Transfer method is via CAN using a two-wire twisted shielded cable with two-wire bus power cable and drain. The baud rates used for communication include 125K baud, 250K baud and 500K baud.
## **Johnson Controls Metasys N2 Network Communications**
The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. The N2 fieldbus is available as a factory installed option and as a field installable kit.
## **Modbus/TCP Network Communications**
The Modbus/TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks utilizing Modbus protocol. It includes an RJ-45 pluggable connector. This interface provides a selection of standard and custom register values to communicate drive parameters. The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable over Ethernet using a supplied software tool.
## **BACnet Network Communications**
The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks. It includes a 5.08 mm pluggable connector. Data transfer is Master-Slave/ Token Passing (MS/TP) RS-485. This interface uses a collection of 30 Binary Value Objects (BVOs) and 35 Analog Value Objects (AVOs) to communicate drive parameters. The card supports 9.6, 19.2 and 38.4 Kbaud communication speeds and supports network addresses 1–127.
## **EtherNet/IP Network Communications**
The EtherNet/IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet/Industrial Protocol networks. It includes an RJ-45 pluggable connector. The interface uses CIP objects to communicate drive parameters (CIP is “Common Industrial Protocol”, the same protocol used by DeviceNet). The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable by Static, BOOTP and DHCP methods.
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-95**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**Control/Communication Option Descriptions**_
For availability, see Product Selection for base drive voltage required.
**2**
## **Available Control/Communications Options**
|**Option**|**Description**|**Option Type**|
|---|---|---|
|**K1**|**Door-Mounted Speed Potentiometer**—Provides the SVX9000 with the ability to adjust the frequency reference using a door-mounted potentiometer. This option uses<br>the 10 Vdc reference to generate a 0–10V signal at the analog voltage input signal terminal. When the HOA bypass option is added, the speed is controlled when the<br>HOA switch is in the HAND position. Without the HOA bypass option, a two-position switch (labeled local/remote) is provided on the keypad to select speed reference from the|Control|
|**K2**|speed potentiometer or a remote speed signal.<br>**Door-Mounted Speed Potentiometer with HOA Selector Switch—**Provides the SVX9000 with the ability to start/stop and adjust the speed reference from|Control|
||door-mounted control devices or remotely from customer supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-mounted speed<br>potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry contact and||
||4–20 mA signal.||
|**K4**|**HAND/OFF/AUTO Switch for Non-Bypass Configurations**—Provides a three-position selector switch that allows the user to select either a HAND or AUTO mode of|Control|
||operation. HAND mode is defaulted to k (keypad operation, and AUTO mode is defaulted to control from an external terminal source. These modes of operation can be||
|**K5**|configured via programming to allow for alternate combinations of start and speed sources. Start and speed sources include keypad, I/O and fieldbus.<br>**MANUAL/AUTO Speed Reference Switch**—Provides a door-mounted selector switch for MANUAL/AUTO speed reference.|Control|
|**K6**|**START/STOP Pushbuttons**—Provide door-mounted START and STOP pushbuttons for either bypass or non-bypass configurations.|Control|
|**KB**|**115V Control Transformer, 500 VA**—Provides a fused control power transformer with additional 500 VA at 115V for customer use.|Control|
|**KF**|**Bypass Test Switch for RB and RA**—Allows the user to energize the AF drive for testing while operating the motor on the bypass controller. The test switch is|Addl. bypass|
||mounted on the inside of the enclosure door.||
|**KO**|**Standard Elapsed Time Meter**—Provides a door-mounted elapsed run time meter.|Control|
|**L1**|**POWER ON, RUN and FAULT Pilot Lights**—Provide a white POWER ON light that indicates power to the enclosed cabinet, a green RUN light that indicates the drive|Light|
||is running and a red FAULT light that indicates a drive fault has occurred.||
|**L2**|**Bypass Pilot Lights for RA and RB Bypass Options**—A green MOTOR ON INVERTER light indicates when the motor is running in inverter mode and an amber|Addl. bypass|
||MOTOR ON BYPASS light indicates when the motor is running in bypass mode. The lights are mounted on the enclosure door, above the switches.||
|**LA**|**Green RUN Light (22 mm)**—Provides a green RUN light that indicates the drive is running.|Light|
|**LD**|**Green STOP Light (22 mm)**—Provides a green STOP light that indicates the drive is stopped.|Light|
|**LE**<br>**LF**|**Red RUN Pilot Light (22 mm)**—Provides a red RUN pilot light that indicates the drive is running.<br>**Red STOP Light (22 mm)**—Provides a red STOP light that indicates the drive is stopped.|Light<br>Light|
|**LJ**|**White POWER ON Light (22 mm)**—Provides a white POWER ON light that indicates power to the enclosed cabinet.|Light|
|**LU**|**Misc. Light (22 mm)**—Provides a misc. “user defined” pilot light. User to define light function and color.|Light|
|**P1**|**Input Circuit Breaker**—Provides a means of short-circuit protection for the power cables between it and the SVX9000, and protection from high-level ground faults on<br>the power cable. Allows a convenient means of disconnecting the SVX9000 from the line and the operating mechanism can be padlocked in the OFF position. This is factory|Input|
|**P3**|mounted in the enclosure.<br>**Input Line Fuses Rated to 200 kAIC**—Provides high-level fault protection of the SVX9000 input power circuit from the load side of the fuses to the input side of the|Input|
|**P8**|power transistors. This option consists of three 200 kA fuses, which are factory mounted in the enclosure.<br>**SPD (50 kA per Phase)**—Provides a surge protection device (SPD) connected to the line side terminals and is designed to clip line side transients.|Input|
||Rated for 50,000A.||
|**PA**|**SPD (100 kA per Phase)**—Provides a surge protection device (SPD) connected to the line side terminals and is designed to clip line side transients.|Input|
||Rated for 100,000A.||
|**PE**|**Output Contactor**—Provides a means for positive disconnection of the drive output from the motor terminals. The contactor coil is controlled by the drive’s run or|Output|
||permissive logic. NC and NO auxiliary contacts rated at 10A, 600 Vac are provided for customer use. Bypass options**RB**and**RA**include an output contactor as standard.||
||This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure.||
|**PF**|**Output Filter (100–300 ft)**—Used to reduce the transient voltage (DV/DT) at the motor terminals. The output filter is recommended for cable lengths exceeding 100 ft|Output|
||(30m) with a drive of 3 hp and above, for cable lengths of 33 ft (10m) with a drive of 2 hp and below, or for a drive rated at 525–690V. This option is mounted in the enclosure,<br>and may be used in conjunction with a brake chopper circuit.||
|**PG**|**MotoRX (300–600 ft) 1000 V/μS DV/DT Filter**—Used to reduce transient voltage (DV/DT) and peak voltages at the motor terminals. This option is comprised of a 0.5%<br>line reactor, followed by capacitive filtering and an energy recovery/clamping circuit. Unlike the output filter (See option**PF**), the MotoRx recovers most of the energy from the|Output|
||voltage peaks, resulting in a lower voltage drop to the motor, and therefore conserving power. This option is used when the distance between a single motor and the drive||
||is 300–600 ft (91–183m)._This option can not be used with the brake chopper circuit. The output filter (option_**_PF_**_) should be investigated as an alternative._||
|**PH**|**Single Overload Relay**—Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options. It is|Output|
||included with the bypass configurations for overload current protection in the bypass mode. The overload relay is mounted within the enclosure, and is manually<br>resettable. Heater pack included.||
|**PI**|**Dual Overload Relays**—This option is recommended when a single drive is operating two motors and overload current protection is needed for each of the motors. The<br>standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a 100 hp drive would include|Output|
||two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable. Heater packs not included.||
|**PN**|**Dual Overloads for Bypass**—This option is recommended when a single drive is operating two motors in the bypass mode and overload current protection is needed|Addl. bypass|
||for each of the motors. The standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a||
||100 hp drive would include two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable.||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-96**
Adjustable Frequency Drives SVX9000 Drives
2.5
For availability, see Product Selection for base drive voltage required.
## **Available Control/Communications Options, continued**
|**Option**|**Description**|**Option Type**|
|---|---|---|
|**RA**|**Manual HOA Bypass Controller**—The manual HAND/OFF/AUTO (HOA)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing the AC<br>motor to be operated at full speed directly from the AC supply line. This option consists of an input disconnect, a fused control power transformer, and a full voltage|Bypass|
||bypass starter with a door mounted HOA selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in the inverter<br>mode. For applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output contactor, and a Freedom Series IEC starter with a bimetallic||
||overload relay is included. For applications above 100 hp, an Advantage input contactor, an Advantage output contactor and an Advantage starter with electronic||
||overload protection is included. The contactors are mechanically and electrically interlocked.||
|**RB**|**Manual IOB Bypass Controller**—The manual INVERTER/OFF/BYPASS (IOB)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing|Bypass|
||the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input disconnect, a fused control power transformer, and a full<br>voltage bypass starter with a door mounted IOB selector switch. For applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output||
||contactor, and a Freedom Series IEC starter with a bimetallic overload relay is included. For applications above 100 hp, an Advantage input contactor, an Advantage||
||output contactor and an Advantage starter with electronic overload protection is included. The contactors are mechanically and electrically interlocked.||
|**RC**|**Auto Transfer HOA Bypass Controller**—The manual HAND/OFF/AUTO (HOA)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing|Bypass|
||the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the line” operation after a<br>drive trip. This option consists of an input disconnect, a fused control power transformer, and a full voltage bypass starter with a door mounted HOA selector switch and||
||an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in either mode. For applications up to 100 hp, a Freedom Series IEC input||
||contactor, a Freedom Series IEC output contactor, and a Freedom Series IEC starter with a bimetallic overload relay is included. For applications above 100 hp, an Advantage input<br>contactor, an Advantage output contactor and an Advantage starter with electronic overload protection is included. The contactors are mechanically and electrically||
||interlocked. Door-mounted pilot lights are provided which indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an<br>amber light indicates when the motor is running in bypass mode.||
||**WARNING**: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.||
|**RD**|**Auto Transfer IOB Bypass Controller**—The auto INVERTER/OFF/BYPASS (IOB)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing<br>the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the line” operation after a|Bypass|
||drive trip. This option consists of an input disconnect, a fused control power transformer, and a full voltage bypass starter with a door mounted IOB selector switch. For<br>applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output contactor, and a Freedom Series IEC starter with a bimetallic overload relay||
||is included. For applications above 100 hp, an Advantage input contactor, an Advantage output contactor and an Advantage starter with electronic overload protection is||
||included. The contactors are mechanically and electrically interlocked. Door-mounted pilot lights are provided which indicate bypass or inverter operation. A green light<br>indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in bypass mode.||
||**WARNING**: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.||
|**S5**|**Floor Stand 22 in**—Converts a Size 1 or 2, normally wall mounted enclosure to a floor standing enclosure with a height of 22 in (558.8 mm).|Enclosure|
|**S6**<br>**S7**|**Floor Stand 12 in**—Converts a Size 2, normally wall mounted enclosure to a floor standing enclosure with a height of 12 in (304.8 mm).<br>**10 in** **Expansion**—In a Size 5 enclosure, the extension allows for bottom cable entry and additional space for customer mounted components.|Enclosure<br>Enclosure|
|**S8**|**NOTE:**Enclosure expansion rated NEMA Type 1/IP21 only.<br>**20 in** **Expansion**—In a Size 5 enclosure, the extension allows for bottom cable entry and additional space for customer mounted components. When the output filter|Enclosure|
||(option**PF**) is selected for a drive using a Size 5 enclosure, this expansion box is required and included in the option pricing.<br>Enclosure expansion rated NEMA Type 1/IP21 only.||
|**S9**|**Space Heater**—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature control. A|Enclosure|
||200W heater is installed in enclosures 0 and 1, and a 400W heater is installed in enclosures 2–5.||
|**SA**|**Space Heater with CPT**—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature|Enclosure|
||control. A 200W heater is installed in enclosures 0 and 1, and a 400W heater is installed in enclosures 2–5. Includes a 115V supply to power heater.||
## _**Enclosed Drive Options**_
## _**SVX Conversion Kit**_
## **Brake Chopper Options**
## **Frame 4–7**[1]
|**Frame 4–7**|1||
|---|---|---|
|**Frame**<br>**Size**|**Enclosure**<br>**Size**<br>**Delivery**<br>**Code**|**Catalog Number**|
|FR4|0<br>FB10<br>1|**OPTCON-SVXFR4-SZ00**|
|||**OPTCON-SVXFR4-SZ01**|
|FR5|0<br>FB10<br>1|**OPTCON-SVXFR5-SZ00**|
|||**OPTCON-SVXFR5-SZ01**|
|FR6|1<br>FB10<br>2|**OPTCON-SVXFR6-SZ01**|
|||**OPTCON-SVXFR6-SZ02**|
|FR7|2<br>FB10|**OPTCON-SVXFR7-SZ02**|
The brake chopper circuit option is used for applications that require dynamic braking. Dynamic braking resistors are not included with drive purchase. Consult **Page V6-T2-58** for dynamic braking resistors which are supplied separately. Resistors are not UL Listed.
For brake chopper circuit selection and adder—NEMA Type 1/IP21, NEMA Type 12/IP54, consult the factory
**2**
## _**Note**_
> 1 The kit consists of a flange kit, adapter plate(s), hardware, remote keypad kit and SVX9000 decal.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-97**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Technical Data and Specifications**
**2**
## **9000X Enclosed Drives**
|**Description**<br>**NEMA Type 1/IP21 or NEMA Type 12/IP54**<br>**Specification**<br>**Primary Design Features**<br>45–66 Hz input frequency<br>Standard<br>Output: AC volts maximum<br>Input voltage base<br>Output frequency range<br>0–320 Hz<br>Initial output current (IH)<br>250% for 2 seconds<br>Overload (1 minute [IH/IL])<br>150%/110%<br>Enclosure space heater<br>Optional<br>Oversize enclosure<br>Standard<br>Output contactor<br>Optional<br>Bypass motor starter<br>Optional<br>Listings<br>UL, cUL<br>**Protection Features**<br>Incoming line fuses<br>Optional<br>AC input circuit disconnect<br>Optional<br>Line reactors (3%)<br>Standard<br>Phase rotation insensitive<br>Standard<br>EMI filter<br>Standard<br>Input phase loss protection<br>Standard<br>Input overvoltage protection<br>Standard<br>Line surge protection<br>Optional<br>Output short-circuit protection<br>Standard<br>Output ground fault protection<br>Standard<br>Output phase protection<br>Standard<br>Overtemperature protection<br>Standard<br>DC overvoltage protection<br>Standard<br>Drive overload protection<br>Standard<br>Motor overload protection<br>Standard<br>Programmer software<br>Optional<br>Local/remote keypad<br>Standard<br>Keypad lockout<br>Standard<br>Fault alarm output<br>Standard<br>Built-in diagnostics<br>Standard|**Description**<br>**NEMA Type 1/IP21 or NEMA Type 12/IP54**<br>**Specification**|
|---|---|
||**Input/Output Interface Features**|
||Setup adjustment provisions|
||Remote keypad/display<br>Standard|
||Personal computer<br>Standard|
||Operator control provisions|
||Drive mounted keypad/display<br>Standard|
||Remote keypad/display<br>Standard|
||Conventional control elements<br>Standard|
||Serial communications<br>Optional|
||115 Vac control circuit<br>Optional|
||Speed setting inputs|
||Keypad<br>Standard|
||0–10 Vdc potentiometer/voltage signal<br>Standard|
||4–20 mA Isolated<br>Configurable|
||4–20 mA Differential<br>Configurable|
||Analog outputs|
||Speed/frequency<br>Standard|
||Torque/load/current<br>Programmable|
||Motor voltage<br>Programmable|
||Kilowatts<br>Programmable|
||0–10 Vdc signals<br>Configurable w/jumpers|
||4–20 mA DC signals<br>Standard|
||Isolated signals<br>Optional|
||Discrete outputs|
||Fault alarm<br>Standard|
||Drive running<br>Standard|
||Drive at set speed<br>Programmable|
||Optional parameters<br>14|
||Dry contacts<br>1 (2 relays Form C)|
||Open collector outputs<br>1|
||Additional discrete outputs<br>Optional|
||Communications|
||RS-232<br>Standard|
||RS-422/485<br>Optional|
||DeviceNet™<br>Optional|
||Modbus RTU<br>Optional|
||CANopen (slave)<br>Optional|
||PROFIBUS-DP<br>Optional|
||Lonworks®<br>Optional|
||Johnson Controls Metasys™ N2<br>Optional|
||EtherNet/IP<br>Optional|
||Modbus TCP<br>Optional|
||BACnet<br>Optional|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-98**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Standard I/O Specifications**
## **9000X Enclosed Drives, continued**
|**Description**<br>**NEMA Type 1/IP21 or NEMA Type 12/IP54**<br>**Specification**<br>**Performance Features**<br>Sensorless vector control<br>Standard<br>Volts/hertz control<br>Standard<br>IR and slip compensation<br>Standard<br>Electronic reversing<br>Standard<br>Dynamic braking<br>Optional1<br>DC braking<br>Standard<br>PID setpoint controller<br>Programmable<br>Critical speed lockout<br>Standard<br>Current (torque) limit<br>Standard<br>Adjustable acceleration/deceleration<br>Standard<br>Linear or S curve accel/decel<br>Standard<br>Jog at preset speed<br>Standard<br>Thread/preset speeds<br>7 Standard, 15 Optional<br>Automatic restart<br>Selectable<br>Coasting motor start<br>Standard<br>Coast or ramp stop selection<br>Standard<br>Elapsed time meter<br>Optional<br>Carrier frequency adjustment<br>1–16 kHz<br>**Standard Conditions for Application and Service**<br>Operating ambient temperature<br>0 to 40°C<br>Storage temperature<br>–40 to 60°C<br>Humidity (maximum), non-condensing<br>95%<br>Altitude (maximum without derate)<br>3300 ft (1000m)<br>Line voltage variation<br>+10/–15%<br>Line frequency variation<br>45–66 Hz<br>Efficiency<br>>96%<br>Power factor (displacement)<br>>0.94|**Description**<br>**Specification**|
|---|---|
||Six–digital input<br>programmable<br>24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V,Ri>5 kohms|
||Two–analog input<br>configurable w/jumpers<br>Voltage: 0–±10V, Ri>200 kohms<br>Current: 0 (4)–20 mA, Ri= 250 ohms|
||Two–digital output<br>programmable<br>Form C relays 250 Vac<br>30 Vdc 2 amp resistive|
||One–analog output<br>programmable<br>configurable w/jumper<br>0–20 mA, RLmax. 500 ohms 10 bits ±2%|
||One digital output<br>programmable<br>Open collector 48 Vdc 50 mA|
||**I/O Specifications for Control/Communication Options**<br>**Description**<br>**Specification**|
||Analog voltage, input<br>0–±10V, Ri ><br>~~2~~00 kohms|
||Analog current, input<br>0 (4)–20 mA, Ri= 250 ohms|
||Digital input<br>24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V, Ri>5 kohms|
||Auxiliary voltage<br>24V (±20%), max. 50 mA|
||Reference voltage<br>10V ±3%, max. 10 mA|
||Analog current, output<br>0 (4)–20 mA, RL= 500 kohms resolution 10 bit,<br>accuracy <<br>±2%|
||Analog voltage, output<br>0 (2)–10V, RL ><br>~~1~~kohms, resolution 10 bit,<br>accuracy <<br>±2%|
||Relay output|
||Maximum switching voltage<br>300 Vdc, 250 Vac|
||Maximum switching load<br>8A/24 Vdc, 0.4A/300 Vdc, 2 kVA/250 Vac|
||Maximum continuous load<br>2A rms|
||Thermistor input<br>Rtrip= 4.7 kohms|
||Encoder input<br>24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V, Ri= 2.2 kohms<br>5V: “0” <<br>~~2~~V, “1” ><br>~~3~~V, Ri= 330 ohms|
||**_Note_**|
**2**
> 1 Some horsepower units include dynamic braking chopper as standard—refer to individual drive sections.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-99**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2**
## _**9000X Enclosed Drives**_
## **Size 0**
||1.50|1.50|(38.1)||||||||||||||||||||||||||||||||||||||||||||For Cable|For Cable|For Cable|For Cable||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||Lifting Holes<br>4 Places|||||||||K||||||||||||||||||||||||||||||||K||||||Entry|||V|||||
|||||||||||||||||||||||||||||||||J||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||||||||||||||U|||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
||||||||||||||||||||||||||||||||||||||||||||||||||||L|||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|B||||||||F||H|||||||||||||||||||||||||||||||||S||||||T|||||||
|||||||||||||||||||||||||||||||||||||||||||||||**Top**|**View**||R|||For Cable<br>Entry||||
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
||||C|||||||||||||||||||||||D|||||||||||||||||||||||||P|||||
||||||||||||||0.44|||||||(11.2)<br>A|||||||||||||||||||||||||||||||W|||||
||||||||||||Mounting|||||||||||||Holes||||||||||||||||||||||||||||||||
||||||||||||||||4||Places||||||||||||||||||||||||||||||||||V|||||
|||||||||**NEMA Type**<br>**NEMA Type 12/IP54**|||||||||**1/IP21, NEMA Type 12/IP54**<br>**Includes Cover Plates Over Louvers**|||||||||||||||||||||||||||||**Bottom View**||||||||||
|For reference only,||||||||dimensions||are||subject||||||||||||||to||||change.||||||||||||||||||||||||||
|**Wide**|||**High**|||||**Deep**|||**Mounting**||||||||||||||||||||||||||||||||||||||||||**Door Height**|**Min. Air Space**||
|**A**|||**B**|||||**C**|||**D**|||||||||||||||**D1**||||||||||||||||**E**|**E1**|||**F**|||**G**|||**G1**|**H**|**J**|**K**|
|19.9 (504)|||29.0 (737)|||||16.4 (416)|||18.3||||(465)|||||||||||—||||||||||||||||—|—|||27.4 (695)|||—|||—|25.4 (644)|4.0 (102)|3.0 (76)|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||**Max. Approx.**||
|**Cable Entry**<br>**L**|||**M**|||||**N**|||**P**|||||||||||||||**R**||||||||||||||||**Door Clearance**<br>**S**||||**CB Handle**<br>**T**|||**U**|||**V**|**W**|**Shipping Weight**<br>**Lbs (kg)**||
|5.0 (127)|||—|||||—|||6.0||(152)|||||||||||||9.6||||(245)||||||||||||26.4|(669)|||1.5 (38)|||6.3|(160)||4.3 (108)|5.3 (134)|200 (91)||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-100**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Size 1**
**==> picture [447 x 358] intentionally omitted <==**
**----- Start of picture text -----**<br>
2.50 (63.5) 2.50 (63.5) D<br>Lifting Holes4 Places K Lifting Holes4 Places AA K<br>J J<br>H H<br>B B<br>F<br>X CC<br>C D<br>BB<br>A<br>0.44 (11.2)<br>Mounting Holes<br>4 Places<br> NEMA Type 1/IP21, NEMA Type 12/IP54<br>NEMA Type 12/IP54 Includes Cover Plates Over Louvers<br>Y Z DD<br>C A<br> NEMA Type 1/IP21, NEMA Type 12/IP54<br>with Floor Stand<br>0.44 (11.2)<br>For Cable Mounting Holes<br>M N Entry For Cable 6 Places NN<br>Entry For Cable<br>For Cable Entry<br>L Entry EE<br>For Cable P MM<br>Entry FF EE<br>S U KK<br>T R JJ U<br>GG LL<br>Top View Bottom View HH<br>Bottom View<br> NEMA Type 1/IP21, NEMA Type 12/IP54<br>with Floor Stand<br>**----- End of picture text -----**<br>
**NEMA Type 1/IP21, NEMA Type 12/IP54 NEMA Type 12/IP54 Includes Cover Plates Over Louvers**
**2**
For reference only, dimensions are subject to change.
|**Wide**|**High**||**Deep**|**Mounting**|||||||||||**Door Height**|**Door Height**|**Min. Air**|**Space**||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**|**B**||**C**|**D**|**D1**||**E**|**E1**||**F**||**G**|**G1**||**H**||**J**|**K**||
|26.4 (669)|36 (914)||16.3 (414)|24.8 (630)|—||—|—||34.0 (864)||—|—||32.4 (822)||4.0 (102)|3.0|(76)|
|**Cable Entry**|||||||**Door Clearance**|||**CB Handle**|||||||**Max. Approx.**<br>**Shipping Weight**|||
|**L**<br>11.0 (279)|**M**<br>6.0 (152)||**N**<br>9.0 (229)|**P**<br>10.0 (254)|**R**<br>6.5|(165)|**S**<br>26.4 (669)|||**T**<br>1.5 (38)||**U**<br>4.3 (108)|**V**<br>—||**W**<br>—||**Lbs (kg)**<br>230 (104)|||
|**Floor Stand**||||||||||||||||||||
|**X**<br>**Y**<br>56.0<br>4.3|**Z**<br>11.1|**AA**<br>1.8|**BB**<br>0.8|**CC**<br>**DD**<br>55.2<br>26.0|**EE**<br>3.5|**FF**<br>5.5|**GG**<br>3.0|**HH**<br>6.0|**JJ**<br>2.0|**KK**<br>5.4|**LL**<br>1.1|**MM**<br>8.8|**NN**<br>5.4|**PP**<br>—|**RR**<br>—|**SS**<br>—|**TT**<br>—|**UU**<br>—|**VV**<br>—|
|(1422)<br>(108)|(281)|(46)|(19)|(1402)<br>(660)|(90)|(141)|(76)|(152)|(51)|(136)|(28)|(224)|(137)|||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-101**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Size 2**
**==> picture [533 x 404] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 2.50 (63.5) 2.50 (63.5) D<br>Lifting Holes Lifting Holes AA<br>2 2 Places J 2 Places J<br>K K<br>2 Lifting Holes2.50 (63.5) AA D<br>2 Places<br>J<br>2 K<br>2<br>H H<br>B B<br>2 F PP<br>NN<br>2 XB H<br>CC<br>2<br>2 C D BB<br>A<br>2 0.44 (11.2)<br>Mounting Holes<br>4 Places<br>2 NEMA Type 1/IP21, NEMA Type 12/IP54 BB<br>NEMA Type 12/IP54 Includes<br>Cover Plates Over Louvers<br>2 Y Z DD Y Z DD<br>C A C A<br>2 NEMA Type 1/IP21, NEMA Type 12/IP54with 22 in Floor Stand NEMA Type 1/IP21, NEMA Type 12/IP54with 12 in Floor Stand<br>2 For CableEntry For CableEntry For CableEntry For CableEntry 0.44 (11.2) Mounting<br>Holes 6 Places<br>2 EE<br>P MM<br>FF EE<br>2 L<br>U U V<br>S<br>2 T R JJ<br>Top View Bottom View GG KK LL<br>HH<br>2 Bottom View<br> NEMA Type 1/IP21, NEMA Type 12/IP54<br>with Floor Stand<br>2<br>**----- End of picture text -----**<br>
For reference only, dimensions are subject to change.
|**Wide**||**High**||**Deep**|**Deep**|**Mounting**|**Mounting**|||||||||||**Door Height**|**Door Height**|**Min. Air**|**Space**||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**<br>26.4 (669)||**B**<br>59.0 (1499)||**C**<br>19.4 (492)||**D**<br>24.8 (630)||**D1**<br>—||**E**<br>—|**E1**<br>—||**F**<br>57.0 (1448)||**G**<br>—|**G1**<br>—||**H**<br>55.4 (1406)||**J**<br>4.0 (102)|**K**<br>3.0|(76)|
|||||||||||||||||||||**Max. Approx.**|||
|**Cable Entry**||||||||||**Door Clearance**|||**CB Handle**|||||||**Shipping Weight**|||
|**L**||**M**||**N**||**P**||**R**||**S**|||**T**||**U**|**V**||**W**||**Lbs (kg)**|||
|5.9 (149)||—||—||12.4 (315)||9.5|(241)|26.4 (669)|||1.5 (38)||4.8 (121)|5.9|(151)|—||380 (173)|||
|**Floor Stand**|||||||||||||||||||||||
|**X**|**Y**|**Z**|**AA**||**BB**|**CC**|**DD**|**EE**|**FF**|**GG**|**HH**|**JJ**|**KK**|**LL**|**MM**|**NN**|**PP**|**RR**|**SS**|**TT**|**UU**|**VV**|
|69.0|4.8|13.6|1.8||0.8|68.2|26.0|4.8|6.8|3.0|6.0|2.0|5.0|1.1|11.3|79.0|78.2|—|—|—|—|—|
|(1753)|(121)|(344)|(46)||(19)|(1732)|(660)|(121)|(172)|(76)|(152)|(51)|(127)|(28)|(288)|(2007)|(1986)||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-102**
Adjustable Frequency Drives
2.5
SVX9000 Drives
**2**
Approximate Dimensions in Inches (mm)
## **Size 3**
**==> picture [373 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
0.50 (12.7)<br>Lifting Eyes<br>2 Places K<br>J<br>M P<br>V<br>For Cable<br>Entry U<br>L<br>S<br>T<br>Top View<br>H<br>B RR<br>0.44 (11.2)<br>Mounting Holes<br>6 Places For Cable<br>R Entry<br>F N<br>G<br>TT W<br>SS UU G1 D1 D<br>C A E1 E<br>VV<br>Bottom View<br>**----- End of picture text -----**<br>
**NEMA Type 1/IP21, NEMA Type 12/IP54 NEMA Type 12/IP54 Includes Cover Plates Over Louvers**
For reference only, dimensions are subject to change.
|**Wide**||**High**|**High**|**Deep**||**Mounting**|**Mounting**||||||||||||**Door Height**|**Min. Air Space**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**<br>26.4 (671)||**B**<br>77.0|(1956)|**C**<br>19.4 (493)||**D**<br>19.5|(495)|**D1**<br>3.3 (83)||**E**<br>23.0|(584)|**E1**<br>1.5|(38)|**F**<br>11.7 (298)|**G**<br>5.5 (140)||**G1**<br>0.9|(24)|**H**<br>76.4 (1939)|**J**<br>**K**<br>4.0 (102)<br>3.0 (76)|
|**Cable Entry**<br>**L**<br>**M**|||**N**|**P**|**R**||**Door Clearance**<br>**S**||**CB**<br>**T**|**Handle**<br>**U**|||**V**|**W**|**RR**|**SS**||**TT**|**UU**|**Max. Approx.**<br>**Shipping Weight**<br>**Lbs (kg)**<br>**VV**|
|5.3|23.4||10.0|1.3|12.9||26.4||1.5||8.0||4.8|6.8|79.5|13.40||0.8|1.3|26.0<br>690 (313)|
|(133)|(594)||(254)|(32)|(328)||(669)||(38)||(203)||(121)|(173)|(2018)|(340)||(19)|(32)|(660)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-103**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Size 4**
**==> picture [417 x 274] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 0.50 (12.7)<br>Lifting Eyes<br>2 Places K<br>2 J<br>M P<br>2<br>V<br>2 For CableEntry U<br>2 L<br>S<br>2 T<br>H Top View<br>2 B RR<br>0.44 (11.2)<br>Mounting Holes For Cable<br>2 6 Places Entry<br>R<br>2<br>F N<br>2<br>G<br>2 SSTT<br>G1 D1 D<br>C A<br>2 E1 E<br> NEMA Type 1/IP21, NEMA Type 12/IP54 Bottom View<br> NEMA Type 12/IP54 Includes Cover Plates Over Louvers<br>2<br>**----- End of picture text -----**<br>
For reference only, dimensions are subject to change.
|**Wide**||**High**|**High**|**Deep**||**Mounting**|**Mounting**||||||||||||**Door Height**||**Min. Air Space**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**<br>26.4 (671)||**B**<br>90.0|(2286)|**C**<br>19.4 (493)||**D**<br>19.5|(495)|**D1**<br>3.3 (83)||**E**<br>23.0|(584)|**E1**<br>1.5|(38)|**F**<br>11.7 (298)|**G**<br>5.5 (140)||**G1**<br>0.9|(24)|**H**<br>89.4 (2270)||**J**<br>**K**<br>4.0 (102)<br>3.0 (76)|
|**Cable Entry**<br>**L**<br>**M**|||**N**|**P**|**R**||**Door Clearance**<br>**S**||**CB**<br>**T**|**Handle**<br>**U**|||**V**|**W**|**RR**|**SS**||**TT**|**UU**|**VV**|**Max. Approx.**<br>**Shipping Weight**<br>**Lbs (kg)**|
|5.3|23.4||13.8|1.0|11.2||26.4||1.5||8.0||4.8|—|92.5|0.8||1.3|—|—|825 (375)|
|(133)|(594)||(351)|(25)|(286)||(669)||(38)||(204)||(121)||(2349)|(19)||(32)||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-104**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Size 5**
**2**
**==> picture [464 x 438] intentionally omitted <==**
**----- Start of picture text -----**<br>
J<br>Lifting Eyes<br>(2 Places)<br>RR<br>N<br>T For Cable<br>Entry L<br>H<br>S<br>M P<br>B<br>A Top View<br>Front View<br> NEMA Type 1/IP21<br>0.56 (14.2) Dia.<br>Mounting<br>Holes<br>(4 Places) F<br>SS<br>G<br>C<br>Side View D1 D<br>Bottom View<br>IL hp<br>208/230V 75<br>100<br>480V 200<br>250<br>Front View<br> NEMA Type 12/IP54<br>**----- End of picture text -----**<br>
For reference only, dimensions are subject to change.
|**Wide**||**High**|**High**|**Deep**||**Mounting**|**Mounting**||||||||||||**Door Height**||**Min. Air Space**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**||**B**||**C**||**D**||**D1**||**E**||**E1**||**F**|**G**||**G1**||**H**||**J**<br>**K**|
|40.0 (1016)||90.0|(2286)|21.3 (541)||36.0|(914)|2.0 (51)||—||—||8.0 (203)|10.8|(273)|—||84.4 (2143)||4.0 (102)<br>—|
|**Cable**|**Entry**||||||**Door Clearance**||||||||||||||**Max. Approx.**<br>**Shipping Weight**|
|**L**<br>15.0|**M**<br>10.0||**N**<br>4.8|**P**<br>2.0|**R**<br>—||**S**<br>36.3||**T**<br>20.0||**U**<br>—||**V**<br>—|**W**<br>—|**RR**<br>94.0|**SS**<br>15.5||**TT**<br>—|**UU**<br>—|**VV**<br>—|**Lbs (kg)**<br>1275 (579)|
|(381)|(254)||(122)|(51)|||(921)||(508)||||||(2387)|(394)||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-105**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
**Size 5-1P**
**2**
**==> picture [498 x 437] intentionally omitted <==**
**----- Start of picture text -----**<br>
J<br>Lifting Eyes<br>(2 Places)<br>RR<br>For Cable<br>Entry N<br>T L<br>S<br>B H Door Clearance M P<br>Top View<br>A<br>Front View<br> NEMA Type 1/IP21 0.56 (14.2) Dia.<br>Mounting Holes For Cable<br>(4 Places) Entry<br>F<br>U<br>V<br>G<br>SS<br>C D1 D<br>M P<br>Bottom View<br>IL hp<br>208/230V 75<br>100<br>480V 200<br>250<br>Front View<br> NEMA Type 12/IP54<br>**----- End of picture text -----**<br>
For reference only, dimensions are subject to change.
|**Wide**||**High**|**High**|**Deep**||**Mounting**|**Mounting**||||||||||||**Door Height**||**Min. Air Space**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**||**B**||**C**||**D**||**D1**||**E**||**E1**||**F**|**G**||**G1**||**H**||**J**<br>**K**|
|50.0 (1270)||90.0|(2286)|21.3 (541)||36.0|(914)|2.0 (51)||—||—||8.0 (203)|10.8|(273)|—||84.4 (2143)||4.0 (102)<br>—|
|**Cable**|**Entry**||||||**Door Clearance**||||||||||||||**Max. Approx.**<br>**Shipping Weight**|
|**L**<br>17.1|**M**<br>8.0||**N**<br>1.3|**P**<br>1.0|**R**<br>—||**S**<br>36.3||**T**<br>20.0||**U**<br>18.4||**V**<br>1.3|**W**<br>—|**RR**<br>94.0|**SS**<br>15.5||**TT**<br>—|**UU**<br>—|**VV**<br>—|**Lbs (kg)**<br>1375 (624)|
|(435)|(203)||(33)|(25)|||(921)||(508)||(466)||(32)||(2387)|(394)||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-106**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
**Size 5-2P**
**2**
**==> picture [490 x 437] intentionally omitted <==**
**----- Start of picture text -----**<br>
J<br>Lifting Eyes<br>(2 Places)<br>RR<br>For Cable<br>Entry N<br>T L<br>B H S Door Clearance M P<br>A Top View<br>Front View<br> NEMA Type 1/IP21 0.56 (14.2) Dia.<br>Mounting Holes For Cable<br>(4 Places) Entry<br>F<br>U<br>V<br>G<br>SS<br>C D1 D<br>M R<br>Bottom View<br>IL hp<br>208/230V 75<br>100<br>480V 200<br>250<br>Front View<br>NEMA Type 12/IP54<br>**----- End of picture text -----**<br>
For reference only, dimensions are subject to change.
|**Wide**||**High**|**Deep**||**Mounting**|**Mounting**|||||||||||**Door Height**||**Min. Air Space**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**||**B**|**C**||**D**||**D1**|**E**||**E1**||**F**|**G**||**G1**||**H**||**J**<br>**K**|
|**Enclosure Size 5-2P**||||||||||||||||||||
|60.0 (1524)||90.0 (2286)|21.3 (541)||36.0|(914)|2.0 (51)|—||—||8.0 (203)|10.8|(273)|—||84.4 (2143)||4.0 (102)<br>—|
|**Cable**<br>**L**|**Entry**<br>**M**|**N**|**P**|**R**||**Door Clearance**<br>**S**||**T**|**U**||**V**|**W**|**RR**|**SS**||**TT**|**UU**|**VV**|**Max. Approx.**<br>**Shipping Weight**<br>**Lbs (kg)**|
|17.0<br>(432)|18.0<br>(457)|1.5<br>(38)|1.0<br>(25)|0.9<br>(23)||36.3<br>(921)||20.0<br>(508)|18.4<br>(466)||1.3<br>(32)|—|94.0<br>(2387)|15.5<br>(394)||—|—|—|1585 (720)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-107**
Adjustable Frequency Drives
## 2.5
SVX9000 Drives
**==> picture [389 x 478] intentionally omitted <==**
**----- Start of picture text -----**<br>
Approximate Dimensions in Inches (mm)<br>2<br>Size 6<br>2<br>2<br>T<br>2<br>2 S Door Clearance<br>Top View<br>2<br>2 J<br>2<br>Keypad<br>2 Flanged Disconnect Supplied<br>with Circuit Breaker When Specified<br>2<br>Operator Elements When Specified,<br>Mounted on These Panels<br>2<br>RR Key-Locking Handle<br>2 B H<br>2<br>2<br>Ventilating Slots<br>2<br>2 Quarter Turn Latch(2 Places)<br>2<br>C A<br>Side View<br>2 Front View<br>M L For Cable Entry<br>2<br>N<br>IL hp<br>2 480V 300 F 0.56 (14.2) Dia.<br>350<br>P Mounting Hole –<br>2 400 (4 Places)<br>G<br>2 D1 D<br>Bottom View<br>**----- End of picture text -----**<br>
For reference only, dimensions are subject to change. See **Page V6-T2-92** , notes 3 and 5 for enclosure and option selection.
|**Wide**||**High**|**High**|**Deep**||**Mounting**|**Mounting**|||||||||||**Door Height**||**Min. Air Space**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**||**B**||**C**||**D**||**D1**|**E**||**E1**||**F**|**G**||**G1**||**H**||**J**<br>**K**|
|30.0 (762)||90.0|(2286)|26.0 (660)||26.5|(673)|1.8 (46)|—||—||17.3 (438)|5.5 (140)||—||84.4 (2143)||4.0 (102)<br>—|
|**Cable Entry**|||||||**Door Clearance**|||||||||||||**Max. Approx.**<br>**Shipping Weight**|
|**L**|**M**||**N**|**P**|**R**||**S**||**T**|**U**||**V**|**W**|**RR**|**SS**||**TT**|**UU**|**VV**|**Lbs (kg)**|
|23.5|3.3||4.5|19.3|—||26.2||24.8|—||—|—|93.9|—||—|—|—|1500 (681)|
|(597)|(84)||(114)|(490)|||(667)||(629)|||||(2386)|||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-108**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm) **Size 8**
||S<br>.<br>–<br>R<br>F<br>G|S<br>.<br>–<br>R<br>F<br>G|T|T|
|---|---|---|---|---|
||||||
||||||
||||||
|||R|||
||||||
||||J||
|||||L<br>RR<br>V<br>N<br>P|
||||||
||||||
||||||
||||M<br>U<br><br>A<br>**Front View**||
||.<br>–||||
||||||
||F||||
||G||||
||||||
||D1||D||
||re subject to<br>**Mounting**<br>**D**<br>**D1**<br>||||
|48.0 (1219)<br>90.0 (2286)<br>24.0 (610)|42.2 (1072)<br>3.0||(77)<br>—<br>—<br>—<br>5.5 (139)<br>—<br>84.4 (2143)<br>4.0 (102)<br>—||
|**Cable Entry**<br>**L**<br>**M**<br>**N**<br>**P**<br>**R**|**S**||**Max. Approx.**<br>**Shipping Weight**<br>**Lbs (kg)**<br>**T**<br>**U**<br>**V**<br>**W**<br>**RR**<br>**SS**<br>**TT**<br>**UU**<br>**VV**||
|9.5<br>(241)<br>37.5<br>(952)<br>12.5<br>(318)<br>7.7<br>(196)<br>8<br>(|.3<br>210)<br>1.3<br>(32)||31.0<br>(787)<br>21.5<br>(545)<br>21.3<br>(541)<br>—<br>93.5<br>(2375)<br>—<br>—<br>—<br>—<br>2000 (908)||
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-109**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Size 9**
**2**
**==> picture [380 x 452] intentionally omitted <==**
**----- Start of picture text -----**<br>
T U<br>S<br>R<br>Access in Top –<br>(2 Places) W<br>V<br>90° Max. 90° Max.<br>Door Door<br>Opening Opening<br>SS UU<br>TT<br>Top View<br>J<br>Openings Filtered for<br>NEMA Type 12/IP54 Design<br>Drive Circuit Breaker<br>Key-Locking Handle<br>RR<br>B<br>Access<br>Plate –<br>4 Places<br>C A<br>Side View Front View<br>M L Bottom Access<br>0.56 (14.2) Dia.<br>Mounting Hole –<br>(5 Places)<br>N<br>G<br>IH hp IL hp<br>P<br>480V 400 500 G1<br>500 550<br>550 600 D1 D D2<br>E<br>Bottom View<br>**----- End of picture text -----**<br>
For reference only, dimensions are subject to change. See **Page V6-T2-92** , notes 3 and 5 for enclosure and option selection.
|**Wide**|**High**||**Deep**|**Mounting**|**Mounting**||||||||||**Door Height**|**Door Height**|**Min. Air Space**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**A**|**B**||**C**|**D**||**D1**||**E**|**E1**|**F**|**G**||**G1**||**H**||**J**<br>**K**|
|60.0 (1524)|90.0 (2286)||260.1 (664)|22.9|(582)|2.0|(51)|30.0 (762)|44.3 (1125)|10.6 (270)|10.6|(270)|8.2|(208)|—||4.0 (102)<br>—|
|**Cable Entry**<br>**L**<br>**M**||**N**|**P**|**R**|**S**||**T**|**U**|**V**|**W**|**RR**|**SS**||**TT**|**UU**|**VV**|**Max. Approx.**<br>**Shipping Weight**<br>**Lbs (kg)**|
|8.5<br>(216)|32.7<br>(831)|12.0<br>(305)|11.9<br>(303)|9.8<br>(249)|1.5<br>(38)||43.5<br>(1105)|15.0<br>(381)|7.5<br>(191)|25.0<br>(635)|93.5<br>(2375)|27.4<br>(696)||290.1<br>(738)|270.1<br>(687)|—|2500 (1135)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-110**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **SVX9000 VFD Pump Panels**
## **Contents**
|**Contents**||**2**|
|---|---|---|
|**_Description_**|**_Page_**||
|SVX9000 Drives . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-48**|**2**|
|SVX9000 Enclosed Drives . . . . . . . . . . . . . . . . . . .|**V6-T2-87**||
|SVX9000 VFD Pump Panels||**2**|
|Catalog Number Selection . . . . . . . . . . . . . . . .<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-112**<br>**V6-T2-113**|**2**|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V6-T2-118**<br>**V6-T2-121**|**2**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-123**<br>**V6-T2-124**|**2**|
## **SVX9000 VFD Pump Panels**
## **Product Description**
## **Features**
- **Standard Enclosed** — ● NEMA Type 12/IP54 or covers a wide range of the NEMA Type 3R enclosures most commonly ordered ● Input voltage: 208V, 230V, options. Pre-engineering 480V and 575V (consult eliminates the lead time factory) normally associated with ● Complete range of control, customer specific options.
- Complete range of control, network and power options
- **Modified Standard** ● Horsepower range: **Enclosed** —applies to ● 208V—3/4 to 100 hp IH; specific customer requirements that vary 1 to 100 hp ILL from the Standard ● 230V—3/4 to 100 hp IH; Enclosed offering, such as 1 to 100 hp ILL the need for an additional ● 480V—1 to 350 hp IH; indicating light or minor 1-1/2 to 400 hp IL modifications to drawings. ● Padlockable disconnect _Consult your Eaton_ ● Single-phase input _representative for_ available _assistance in pricing and lead time._
- 208V—3/4 to 100 hp IH; 1 to 100 hp ILL
- 230V—3/4 to 100 hp IH; 1 to 100 hp ILL
- **Custom Engineered** —for those applications with more unique or complex requirements, these are individually engineered to the customer’s needs. _Consult your Eaton representative for assistance in pricing and lead time._
## **Standards and Certifications**
- UL Listed
- cUL Listed
## **Product Identification**
## **SVX9000 Pump Application**
**==> picture [200 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>6 I 2<br>3<br>4<br>5<br>**----- End of picture text -----**<br>
- 1 SVX9000 variable frequency drive 4 Space heater 2 Input disconnect Option P1 Option S9
- 3 Input contactor (included as 5 Bypass contactor standard with bypass option) Option RA/RB
- 6 Door-mounted keypad (included as standard)
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-111**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Catalog Number Selection**
**2**
**SVX9000 Enclosed NEMA Type 12/IP54/3R Drive**
**==> picture [230 x 341] intentionally omitted <==**
**----- Start of picture text -----**<br>
SVX 010 2 4 E P<br>Product Family<br>SVX = Enclosed drives<br>Horsepower Rating<br>F07 = 3/4 hp 015 = 15 hp 100 = 100 hp<br>001 = 1 hp 020 = 20 hp 125 = 125 hp<br>F15 = 1-1/2 hp 025 = 25 hp 150 = 150 hp<br>002 = 2 hp 030 = 30 hp 200 = 200 hp<br>003 = 3 hp 040 = 40 hp 250 = 250 hp<br>005 = 5 hp 050 = 50 hp 300 = 300 hp<br>007 = 7-1/2 hp 060 = 60 hp 350 = 350 hp<br>010 = 10 hp 075 = 75 hp 400 = 400 hp<br>Enclosure Rating<br>2 = NEMA Type 12/IP54<br>3 = NEMA Type 3R<br>Voltage Rating<br>Three-phase Single-phase<br>1 = 208V J = 230V<br>2 = 230V K = 480V<br>4 = 480V<br>Application—Torque/Braking [2]<br>A = IL/no brake chopper<br>B = IL/internal brake chopper<br>D = IH/no brake chopper<br>E = IH/internal brake chopper<br>Enclosed Style<br>P = Pumping application<br>**----- End of picture text -----**<br>
Build Alphabetically and Numerically
**_** ~~**_ _ _ _ _ _ _ _ _**~~
|||||
|---|---|---|---|
|**Enclosed**||**Options**145|**Type**|
|**K1**<br>**K2**<br>**K5**<br>**K6**<br>**K9**|Door-mounted speed p<br>Door-mounted speed p<br>switch3<br>MANUAL/AUTO refere<br>START and STOP push<br>(2) Factory installed au|otentiometer3<br>otentiometer with HOA selector<br>nce switch (22 mm)<br>buttons (22 mm)<br>xiliary contacts|Control<br>Control<br>Control<br>Control<br>Power|
|**L1**<br>**L2**<br>**LD**<br>**LE**<br>**LU**<br>**LW**|POWER ON, RUN and<br>Bypass pilot lights for<br>Green STOP light<br>Red RUN light<br>Misc. light (22 mm)<br>PTT light (22 mm)|Fault pilot lights<br>RA bypass option7|Light<br>Addl. bypass<br>Light<br>Light<br>Light<br>Light|
|**P1**<br>**P3**<br>**P8**<br>**PA**<br>**PE**<br>**PF**<br>**PG**|Input circuit breaker<br>Input line fuses (200 k<br>SPD (50 kA per phase)<br>SPD (100 kA per phase<br>Output contactor<br>Output filter<br>MotoRX (300–600 ft) 1|AIC)<br>)<br>000 V/μS DV/DT filter|Input<br>Input<br>Input<br>Input<br>Output<br>Output<br>Output|
|**RA**|Manual HOA bypass c|ontroller7|Bypass|
|**S5**<br>**S9**<br>**SA**<br>**SB**<br>**SE**<br>**SF**|Floor stand 22 in<br>Space heater w/out C<br>Space heater w/CPT<br>Socket type control rel<br>On-delay timer<br>Off-delay timer|PT<br>ay|Enclosure<br>Enclosure<br>Enclosure<br>Enclosure<br>Enclosure<br>Enclosure|
|||||
|**Communication**||**Options**6||
|**C2**= Modbus<br>**C3**= PROFIBUS DP<br>**C4**= LonWorks<br>**C5**= PROFIBUS DP (D9 conne<br>**C6**= CANopen (slave)<br>**C7**= DeviceNet<br>**C8**= Modbus (D9 type conne<br>**CA**= Johnson Controls N2<br>**CI**= Modbus TCP<br>**CJ**= BACnet<br>**CQ**= EtherNet/IP<br>**D3**= RS-232 with D9 connect||ctor)<br>ctor)<br>ion||
|||||
|**Control Options**||||
|**B1**= 6 DI, 1 ext +24 Vdc/EXT +24 Vdc<br>**B2**= 1 RO (NC-NO), 1 RO (NO), 1 therm<br>**B4**= 1 AI (mA isolated), 2 AO (mA isolated),<br>1 ext +24 Vdc/EXT +24 Vdc<br>**B5**= 3 RO (NO)<br>**B8**= 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>**B9**= 1 RO (NO), 5 DI 42–240 Vac input||||
## _**Notes**_
- 1 Local/remote keypad is included as the standard control panel.
- 2 Brake chopper is a factory installed option only, see drive options on **Page V6-T2-49** . External dynamic braking resistors not included. See Page **V6-T2-58** .
- 3 Includes local/remote speed reference switch.
- 4 Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
- 5 See **Page V6-T2-120** for descriptions.
- 6 See **Pages V6-T2-118** and **V6-T2-119** for complete descriptions.
- 7 Bypass options applicable only in the pump panel three-phase design.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-112**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Product Selection**
## _**When Ordering**_
- Select a base catalog number that meets the application requirements— nominal horsepower, voltage and enclosure rating (the enclosed drive’s continuous output amp rating should be equal to or
greater than the motor’s full load amp rating). The base enclosed package includes a standard drive, door mounted local/remote keypad and enclosure.
- If dynamic brake chopper ● Select enclosed options. **2** or control/communication Add the codes as suffixes option is desired, change to the base catalog number **2** the appropriate code in the in alphabetical and numeric base catalog number. order.
- **Read all footnotes** .
## _**208V Drives**_
|**_208V Drives_**|||||||
|---|---|---|---|---|---|---|
|**SVX9000 Enclosed**|**Pump Panel Style (Three-Phase)**|**Pump Panel Style (Three-Phase)**|||||
|**Drives**|||**NEMA Type 12/IP54**||**NEMA Type 3R**||
|.|**Enclosure**<br>**Size**1<br>**High Overload Drive and Enclosure**<br>A|**hp**<br>**Frame**<br>**Size**<br>**High Overload Drive and Enclosure**<br>3/4<br>4<br>1<br>1-1/2<br>2<br>3<br>5||**Base Catalog**<br>**Number**2<br>**SVXF0721EP**<br>**SVX00121EP**<br>**SVXF1521EP**<br>**SVX00221EP**<br>**SVX00321EP**|**Frame**<br>**Size**<br>4<br>5|**Base Catalog**<br>**Number**2<br>**SVXF0731EP**<br>**SVX00131EP**<br>**SVXF1531EP**<br>**SVX00231EP**<br>**SVX00331EP**|
|||5||**SVX00521EP**||**SVX00531EP**|
|||7-1/2||**SVX00721EP**||**SVX00731EP**|
|||10|6|**SVX01021EP**|6|**SVX01031EP**|
|||15||**SVX01521EP**||**SVX01531EP**|
||B|20|7|**SVX02021DP**|7|**SVX02031DP**|
|||25||**SVX02521DP**||**SVX02531DP**|
|||30||**SVX03021DP**||**SVX03031DP**|
||C|40|8|**SVX04021DP**|8|**SVX04031DP**|
|||50||**SVX05021DP**||**SVX05031DP**|
|||60||**SVX06021DP**||**SVX06031DP**|
||F|75|9|**—**|9|**SVX07531DP**|
|||100||**—**||**SVX10031DP**|
||**Low Overload Drive and Enclosure**|**Low Overload Drive and Enclosure**|||||
||A|1|4|**SVX00121BP**|4|**SVX00131BP**|
|||1-1/2||**SVXF1521BP**||**SVXF1531BP**|
|||2||**SVX00221BP**||**SVX00231BP**|
|||3||**SVX00321BP**||**SVX00331BP**|
|||5|5|**SVX00521BP**|5|**SVX00531BP**|
|||7-1/2||**SVX00721BP**||**SVX00731BP**|
|||10||**SVX01021BP**||**SVX01031BP**|
|||15|6|**SVX01521BP**|6|**SVX01531BP**|
|||20||**SVX02021BP**||**SVX02031BP**|
||B|25|7|**SVX02521AP**|7|**SVX02531AP**|
|||30||**SVX03021AP**||**SVX03031AP**|
|||40||**SVX04021AP**||**SVX04031AP**|
||C|50|8|**SVX05021AP**|8|**SVX05031AP**|
|||60||**SVX06021AP**||**SVX06031AP**|
|||75||**SVX07521AP**||**SVX07531AP**|
||F|100|9|**—**|9|**SVX10031AP**|
|||125||**—**||**SVX12531AP**|
## _**Notes**_
- 1 Enclosure dimensions starting on **Page V6-T2-124** .
- 2 Includes drive, local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-113**
2.5
SVX9000 Drives
## Adjustable Frequency Drives
## _**230V Drives**_
**2**
## **SVX9000 Enclosed Drives**
## **Pump Panel Style (Three-Phase)**
|||**NEMA Type 12/IP54**|**NEMA Type 12/IP54**|**NEMA Type 3R**||
|---|---|---|---|---|---|
|**Enclosure**||**Frame**|**Base Catalog**|**Frame**|**Base Catalog**|
|**Size**1|**hp**|**Size**|**Number**2|**Size**|**Number**2|
|**High Overload Drive and Enclosure**|**High Overload Drive and Enclosure**|||||
|A|3/4|4|**SVXF0722EP**|4|**SVXF0732EP**|
||1||**SVX00122EP**||**SVX00132EP**|
||1-1/2||**SVXF1522EP**||**SVXF1532EP**|
||2||**SVX00222EP**||**SVX00232EP**|
||3|5|**SVX00322EP**|5|**SVX00332EP**|
||5<br>7-1/2||**SVX00522EP**<br>**SVX00722EP**||**SVX00532EP**<br>**SVX00732EP**|
||10|6|**SVX01022EP**|6|**SVX01032EP**|
||15||**SVX01522EP**||**SVX01532EP**|
|B|20|7|**SVX02022DP**|7|**SVX02032DP**|
||25||**SVX02522DP**||**SVX02532DP**|
||30||**SVX03022DP**||**SVX03032DP**|
|C|40|8|**SVX04022DP**|8|**SVX04032DP**|
||50||**SVX05022DP**||**SVX05032DP**|
|F|60<br>75|9|**SVX06022DP**<br>**—**|9|**SVX06032DP**<br>**SVX07532DP**|
||100||**—**||**SVX10032DP**|
|**Low Overload Drive and Enclosure**|**Low Overload Drive and Enclosure**|||||
|A|1|4|**SVX00122BP**|4|**SVX00132BP**|
||1-1/2||**SVXF1522BP**||**SVXF1532BP**|
||2||**SVX00222BP**||**SVX00232BP**|
||3||**SVX00322BP**||**SVX00332BP**|
||5|5|**SVX00522BP**|5|**SVX00532BP**|
||7-1/2<br>10||**SVX00722BP**<br>**SVX01022BP**||**SVX00732BP**<br>**SVX01032BP**|
||15|6|**SVX01522BP**|6|**SVX01532BP**|
||20||**SVX02022BP**||**SVX02032BP**|
|B|25|7|**SVX02522AP**|7|**SVX02532AP**|
||30||**SVX03022AP**||**SVX03032AP**|
||40||**SVX04022AP**||**SVX04032AP**|
|C|50|8|**SVX05022AP**|8|**SVX05032AP**|
||60||**SVX06022AP**||**SVX06032AP**|
|F|75<br>100|9|**SVX07522AP**<br>**—**|9|**SVX07532AP**<br>**SVX10032AP**|
||125||**—**||**SVX12532AP**|
## _**Notes**_
> 1 Enclosure dimensions starting on **Page V6-T2-124** .
- 2 Includes drive, local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-114**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**230V Drives, continued**_
**SVX9000 Enclosed**
**==> picture [19 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Drives<br>**----- End of picture text -----**<br>
## **Pump Panel Style (Single-Phase)**
|||**NEMA Type 12/IP54**|**NEMA Type 12/IP54**|**NEMA Type 3R**||
|---|---|---|---|---|---|
|**Enclosure**<br>**Size**1<br>**Low Overload Drive and Enclosure**<br>A|**hp**<br>**Frame**<br>**Size**<br>**Low Overload Drive and Enclosure**<br>3/4<br>4<br>1<br>2<br>5<br>3||**Base Catalog**<br>**Number**2<br>**SVXF072JBP**<br>**SVX0012JBP**<br>**SVX0022JBP**<br>**SVX0032JBP**|**Frame**<br>**Size**<br>4<br>5|**Base Catalog**<br>**Number**2<br>**SVXF073JBP**<br>**SVX0013JBP**<br>**SVX0023JBP**<br>**SVX0033JBP**|
||5||**SVX0052JBP**||**SVX0053JBP**|
||7-1/2|6|**SVX0072JBP**|6|**SVX0073JBP**|
||10||**SVX0102JBP**||**SVX0103JBP**|
|B|15|7|**SVX0152JBP**|7|**SVX0153JBP**|
||20||**SVX0202JAP**||**SVX0203JAP**|
|C|25|8|**SVX0252JAP**|8|**SVX0253JAP**|
||30||**SVX0302JAP**||**SVX0303JAP**|
||40||**SVX0402JAP**||**SVX0403JAP**|
**2**
## _**Notes**_
- 1 Enclosure dimensions starting on **Page V6-T2-124** .
- 2 Includes drive, local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-115**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**480V Drives**_
**2**
## **SVX9000 Enclosed Drives**
## **Pump Panel Style (Three-Phase)**
|||**NEMA Type 12/IP54**|**NEMA Type 12/IP54**|**NEMA Type 3R**||
|---|---|---|---|---|---|
|**Enclosure**||**Frame**|**Base Catalog**|**Frame**|**Base Catalog**|
|**Size**1<br>**High Overload Drive and Enclosure**|**hp**<br>**Size**<br>**High Overload Drive and Enclosure**||**Number**2|**Size**|**Number**2|
|A|1<br>1-1/2|4|**SVX00124EP**<br>**SVXF1524EP**|4|**SVX00134EP**<br>**SVXF1534EP**|
||2<br>3||**SVX00224EP**<br>**SVX00324EP**||**SVX00234EP**<br>**SVX00334EP**|
||5||**SVX00524EP**||**SVX00534EP**|
||7-1/2|5|**SVX00724EP**|5|**SVX00734EP**|
||10||**SVX01024EP**||**SVX01034EP**|
||15||**SVX01524EP**||**SVX01534EP**|
||20|6|**SVX02024EP**|6|**SVX02034EP**|
||25||**SVX02524EP**||**SVX02534EP**|
|B|30|7|**SVX03024EP**|7|**SVX03034EP**|
||40||**SVX04024DP**||**SVX04034DP**|
||50||**SVX05024DP**||**SVX05034DP**|
||60||**SVX06024DP**||**SVX06034DP**|
|C|75|8|**SVX07524DP**|8|**SVX07534DP**|
||100||**SVX10024DP**||**SVX10034DP**|
||125||**SVX12524DP**||**SVX12534DP**|
|F|150|9|**—**|9|**SVX15034DP**|
||200||**—**||**SVX20034DP**|
||250|10|**—**|10|**SVX25034DP**|
||300||**—**||**SVX30034DP**|
||350||**—**||**SVX35034DP**|
||400|113|**—**|11|**SVX40034DP**|
||500||**—**||**SVX50034DP**|
|**Low Overload Drive and Enclosure**|**Low Overload Drive and Enclosure**|||||
|A|1-1/2|4|**SVXF1524BP**|4|**SVXF1534BP**|
||2||**SVX00224BP**||**SVX00234BP**|
||3||**SVX00324BP**||**SVX00334BP**|
||5||**SVX00524BP**||**SVX00534BP**|
||7-1/2||**SVX00724BP**||**SVX00734BP**|
||10|5|**SVX01024BP**|5|**SVX01034BP**|
||15||**SVX01524BP**||**SVX01534BP**|
||20||**SVX02024BP**||**SVX02034BP**|
||25|6|**SVX02524BP**|6|**SVX02534BP**|
||30||**SVX03024BP**||**SVX03034BP**|
|B|40|7|**SVX04024BP**|7|**SVX04034BP**|
||50||**SVX05024AP**||**SVX05034AP**|
||60<br>75||**SVX06024AP**<br>**SVX07524AP**||**SVX06034AP**<br>**SVX07534AP**|
|C|100<br>125|8|**SVX10024AP**<br>**SVX12524AP**|8|**SVX10034AP**<br>**SVX12534AP**|
|F|150<br>200|9|**SVX15024AP**<br>**—**|9|**SVX15034AP**<br>**SVX20034AP**|
||250<br>300|10|**—**<br>**—**|10|**SVX25034AP**<br>**SVX30034AP**|
||350<br>400||**—**<br>**—**||**SVX35034AP**<br>**SVX40034AP**|
||500<br>600|113|**—**<br>**—**|11|**SVX50034AP**<br>**SVX60034AP**|
## _**Notes**_
- 1 Enclosure dimensions starting on **Page V6-T2-124** .
- 2 Includes drive, local/remote keypad and enclosure.
- 3 FR11 has limited power options available.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-116**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**480V Drives, continued**_
**SVX9000 Enclosed**
**==> picture [19 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Drives<br>**----- End of picture text -----**<br>
## **Pump Panel Style (Single-Phase)**
|||**NEMA Type 12/IP54**|**NEMA Type 12/IP54**|**NEMA Type 3R**||
|---|---|---|---|---|---|
|**Enclosure**<br>**Size**1<br>**Low Overload Drive and Enclosure**<br>A|**hp**<br>**Frame**<br>**Size**<br>**Low Overload Drive and Enclosure**<br>3/4<br>4<br>1<br>2<br>3<br>5<br>5||**Base Catalog**<br>**Number**2<br>**SVXF072KBP**<br>**SVX0012KBP**<br>**SVX0022KBP**<br>**SVX0032KBP**<br>**SVX0052KBP**|**Frame**<br>**Size**<br>4<br>5|**Base Catalog**<br>**Number**2<br>**SVXF073KBP**<br>**SVX0013KBP**<br>**SVX0023KBP**<br>**SVX0033KBP**<br>**SVX0053KBP**|
||7-1/2||**SVX0072KBP**||**SVX0073KBP**|
||10||**SVX0102KBP**||**SVX0103KBP**|
||15|6|**SVX0152KBP**|6|**SVX0153KBP**|
||20||**SVX0202KBP**||**SVX0203KBP**|
|B|25|7|**SVX0252KAP**|7|**SVX0253KAP**|
||30||**SVX0302KAP**||**SVX0303KAP**|
|C|40|8|**SVX0402KAP**|8|**SVX0403KAP**|
||50||**SVX0502KAP**||**SVX0503KAP**|
||60||**SVX0602KAP**||**SVX0603KAP**|
**2**
## _**Notes**_
> 1 Enclosure dimensions starting on **Page V6-T2-124** .
- 2 Includes drive, local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-117**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Options**
## _**9000X Series Option Board Kits**_
**2**
The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is designed to accept a total of five option boards.
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2 relay output board, which are installed in slots A and B.
## **Option Boards**
**==> picture [54 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B [C] [D] [E]<br>**----- End of picture text -----**<br>
## **Option Board Kits**
||**Option Board Kits**|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
||||**Field**|**Factory**||||||||
|||**Allowed Slot**|**Installed**<br>**Catalog**|**Installed**<br>**Option**|**SVX Ready Programs**<br>**Local/**|||||||
||**Option Kit Description**1<br>**Standard I/O Cards**|**Locations**2|**Number**|**Designator**|**Basic**|**Remote**|**Standard**|**MSS**|**PID**|**Multi-P.**|**PFC**|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/EXT +24 Vdc|A|**OPTA9**|**—**|■|■|■|■|■|■|■|
||2 RO (NC-NO)|B|**OPTA2**|**—**|■|■|■|■|■|■|■|
||**Extended I/O Cards**|||||||||||
||6 DI, 1 ext +24 Vdc/EXT +24 Vdc|B, C,**D**, E|**OPTB1**|**B1**|—|—|—|—|—|■|■|
||1 RO (NC-NO), 1 RO (NO), 1 therm|B, C,**D**, E|**OPTB2**|**B2**|—|—|—|—|—|■|■|
||1 AI (mA isolated), 2 AO (mA isolated),|B, C,**D**, E|**OPTB4**|**B4**|■|■|■|■|■|■|■|
||1 ext +24 Vdc/EXT +24 Vdc|||||||||||
||3 RO (NO)|B, C,**D**, E|**OPTB5**|**B5**|—|—|—|—|—|■|■|
||1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>1 RO (NO), 5 DI 42–240 Vac input|B, C,**D**, E<br>B, C,**D**, E|**OPTB8**<br>**OPTB9**|**B8**<br>**B9**|—<br>—|—<br>—|—<br>—|—<br>—|—<br>—|—<br>■|—<br>■|
||**Communication Cards**|||||||||||
||Modbus3|D,**E**|**OPTC2**|**C2**|■|■|■|■|■|■|■|
||Modbus TCP|D,**E**|**OPTCI**|**CI**|■|■|■|■|■|■|■|
||BACnet|D,**E**|**OPTCJ**|**CJ**|■|■|■|■|■|■|■|
||EtherNet/IP|D,**E**|**OPTCQ**|**CQ**|■|■|■|■|■|■|■|
||Johnson Controls N23<br>PROFIBUS DP|D,**E**<br>D,**E**|**OPTC2**<br>**OPTC3**|**CA**<br>**C3**|—<br>■|—<br>■|—<br>■|—<br>■|—<br>■|—<br>■|—<br>■|
||LonWorks|D,**E**|**OPTC4**|**C4**|■|■|■|■|■|■|■|
||PROFIBUS DP (D9 connector)|D,**E**|**OPTC5**|**C5**|■|■|■|■|■|■|■|
||CANopen (slave)|D,**E**|**OPTC6**|**C6**|■|■|■|■|■|■|■|
||DeviceNet|D,**E**|**OPTC7**|**C7**|■|■|■|■|■|■|■|
||Modbus (D9 type connector)|D,**E**|**OPTC8**|**C8**|■|■|■|■|■|■|■|
||RS-232 with D9 connection|D,**E**|**OPTD3**|**D3**|■|■|■|■|■|■|■|
## _**Notes**_
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-118**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Modbus RTU Network Communications**
The Modbus Network Card OPTC2 is used for connecting the 9000X Drive as a slave on a Modbus network. The interface is connected by a 9-pin DSUB connector (female) and the baud rate ranges from 300 to 19200 baud. Other communication parameters include an address range from 1 to 247; a parity of None, Odd or Even; and the stop bit is 1.
## **PROFIBUS Network Communications**
The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS-DP network. The interface is connected by a 9-pin DSUB connector (female). The baud rates range from 9.6K baud to 12M baud, and the addresses range from 1 to 127.
## **LonWorks Network Communications**
The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network. This interface uses Standard Network Variable Types (SNVT) as data types. The channel connection is achieved using a FTT-10A Free Topology transceiver via a single twisted transfer cable. The communication speed with LonWorks is 78 kBits/s.
## **CANopen (Slave) Communications**
The CANopen (Slave) Network Card OPTC6 is used for connecting the 9000X Drive to a host system. According to ISO11898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms, and specific line delay of nominal 5 nS/m. 120 ohms line termination resistors required for installation.
## **DeviceNet Network Communications**
The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network. It includes a 5.08 mm pluggable connector. Transfer method is via CAN using a two-wire twisted shielded cable with two-wire bus power cable and drain. The baud rates used for communication include 125K baud, 250K baud and 500K baud.
## **Johnson Controls Metasys N2 Network Communications**
The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. The N2 fieldbus is available as a factory installed option and as a field installable kit.
## **Modbus/TCP Network Communications**
The Modbus/TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks utilizing Modbus protocol. It includes an RJ-45 pluggable connector. This interface provides a selection of standard and custom register values to communicate drive parameters. The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable over Ethernet using a supplied software tool.
## **BACnet Network Communications**
The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks. It includes a 5.08 mm pluggable connector. Data transfer is Master-Slave/ Token Passing (MS/TP) RS-485. This interface uses a collection of 30 Binary Value Objects (BVOs) and 35 Analog Value Objects (AVOs) to communicate drive parameters. The card supports 9.6, 19.2 and 38.4 Kbaud communication speeds and supports network addresses 1–127.
## **EtherNet/IP Network Communications**
The EtherNet/IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet/Industrial Protocol networks. It includes an RJ-45 pluggable connector. The interface uses CIP objects to communicate drive parameters (CIP is “Common Industrial Protocol”, the same protocol used by DeviceNet). The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable by Static, BOOTP and DHCP methods.
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-119**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## _**Control/Communication Option Descriptions**_
For availability, see Product Selection for base drive voltage required.
**2 Available Control/Communications Options**
|**Option**|**Description**|**Option Type**|
|---|---|---|
|**K1**|**Door-Mounted Speed Potentiometer—**Provides the SVX9000 with the ability to adjust the frequency reference using a door-mounted potentiometer. This option uses<br>the 10 Vdc reference to generate a 0–10V signal at the analog voltage input signal terminal. When the HOA bypass option is added, the speed is controlled when the<br>HOA switch is in the HAND position. Without the HOA bypass option, a two-position switch (labeled local/remote) is provided on the keypad to select speed reference from the|Control|
|**K2**|Speed Potentiometer or a remote speed signal.<br>**Door-Mounted Speed Potentiometer with HOA Selector Switch—**Provides the SVX9000 with the ability to start/stop and adjust the speed reference from|Control|
||door-mounted control devices or remotely from customer supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-mounted speed<br>potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry contact and||
||4–20 mA signal.||
|**K5**|**MANUAL/AUTO Speed Reference Switch**—Provides a door-mounted selector switch for MANUAL/AUTO speed reference.|Control|
|**K6**|**START and STOP Pushbuttons (22 mm)**—START (green) STOP (red). Provide door-mounted START and STOP pushbuttons for either bypass or|Control|
||non-bypass configurations.||
|**K9**|**(2) Factory Installed Auxiliary Contacts**—Provide two NO/NC auxiliary contacts.|Power|
|**L2**|**Bypass Pilot Lights for RA and RB Bypass Options**—A green MOTOR ON INVERTER light indicates when the motor is running in inverter mode and an amber|Addl. bypass|
||MOTOR ON BYPASS light indicates when the motor is running in bypass mode. The lights are mounted on the enclosure door, above the switches.||
|**LD**|**Green STOP Light (22 mm)**—Provides a green STOP light that indicates the drive is stopped.|Light|
|**LE**<br>**LU**|**Red RUN Pilot Light (22 mm)**—Provides a red RUN pilot light that indicates the drive is running.<br>**Misc. Light (22 mm)**—Provides a misc. “user defined” pilot light. User to define light function and color.|Light<br>Light|
|**LW**|**PTT (Push-To-Test) Light (22 mm)**—Provides misc. “user defined” PTT pilot light. User to define light function and color.|Light|
|**P1**|**Input Circuit Breaker**—Provides a means of short-circuit protection for the power cables between it and the SVX9000, and protection from high-level ground faults on|Input|
||the power cable. Allows a convenient means of disconnecting the SVX9000 from the line and the operating mechanism can be padlocked in the OFF position. This is factory<br>mounted in the enclosure.||
|**P3**|**Input Line Fuses Rated to 200 kAIC**—Provide high-level fault protection of the SVX9000 input power circuit from the load side of the fuses to the input side of the<br>power transistors. This option consists of three 200 kA fuses, which are factory mounted in the enclosure.|Input|
|**P8**|**SPD (50 kA per Phase)**—Provides a surge protection device (SPD) connected to the line side terminals and is designed to clip line side transients.<br>Rated for 50,000A.|Input|
|**PA**|**SPD (100 kA per Phase)**—Provides a surge protection device (SPD) connected to the line side terminals and is designed to clip line side transients.<br>Rated for 100,000A.|Input|
|**PE**|**Output Contactor**—Provides a means for positive disconnection of the drive output from the motor terminals. The contactor coil is controlled by the drive’s run or|Output|
||permissive logic. NC and NO auxiliary contacts rated at 10A, 600 Vac are provided for customer use. Bypass option**RA**includes an output contactor as standard. This<br>option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure.||
|**RA**|**Manual HOA Bypass Controller**—The Manual HAND/OFF/AUTO (HOA)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing the AC<br>motor to be operated at full speed directly from the AC supply line. This option consists of an input disconnect, a fused control power transformer, and a full voltage|Bypass|
||bypass starter with a door mounted HOA selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in the inverter<br>mode. For applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output contactor, and a Freedom Series IEC starter with a bimetallic<br>overload relay is included. For applications above 100 hp, an Advantage input contactor, an Advantage output contactor and an Advantage starter with electronic||
|**RB**|overload protection is included. The contactors are mechanically and electrically interlocked.<br>**Manual IOB Bypass Controller**—The manual INVERTER/OFF/BYPASS (IOB)—3-contactor—bypass option provides a means of bypassing the SVX9000, allowing|Bypass|
||the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input disconnect, a fused control power transformer, and a full<br>voltage bypass starter with a door mounted IOB selector switch. For applications up to 100 hp, a Freedom Series IEC input contactor, a Freedom Series IEC output||
||contactor, and a Freedom Series IEC starter with a bimetallic overload relay is included. For applications above 100 hp, an Advantage input contactor, an Advantage||
|**S5**|output contactor and an Advantage starter with electronic overload protection is included. The contactors are mechanically and electrically interlocked.<br>**Floor Stand 22 in**—Converts a Size A or B, normally wall mounted enclosure to a floor standing enclosure with a height of 22 in (558.8 mm).|Enclosure|
|**S9**|**Space Heater without CPT**—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable<br>temperature control. A 200W heater is installed in enclosures A and B, and 400W heater is installed in enclosures C and D. Requires a customer supplied 115V remote|Enclosure|
|**SA**|supply source.<br>**Space Heater with CPT**— Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature|Enclosure|
|**SB**|control. A 200W heater is installed in enclosures A and B, and 400W heater is installed in enclosures C and D. Provided with CPT connected to load side of input disconnect.<br>**Ice Cube Style Control Relay**—Provides misc. “user defined” 4PDT control relay. Requires user to define functionality.|Enclosure|
|**SE**<br>**SF**|**On-Delay Timer (Delay on Make)**—Provides misc. “user defined” time delay relay. Requires user to define functionality and time setting requirement.<br>**Off-Delay Timer (Delay on Break)**—Provides misc. “user defined” time delay relay. Requires user to define functionality and time setting requirement.|Enclosure<br>Enclosure|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-120**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Technical Data and Specifications**
## **9000X VFD Pump Panels**
|**Description**<br>**NEMA Type 12/IP54 or NEMA Type 3R**<br>**Specification**<br>**Primary Design Features**<br>45–66 Hz input frequency<br>Standard<br>Output (AC volts maximum)<br>Input voltage base<br>Output frequency range<br>0–320 Hz<br>Initial output current (IH)<br>250% for 2 seconds<br>Overload (1 minute [IH/IL])<br>150%/110%<br>Enclosure space heater<br>Optional<br>Oversize enclosure<br>Standard<br>Output contactor<br>Optional<br>Bypass motor starter<br>Optional<br>Listings<br>UL, cUL<br>**Protection Features**<br>Incoming line fuses<br>Optional<br>AC input circuit disconnect<br>Optional<br>Line reactors (3%)<br>Standard<br>Phase rotation insensitive<br>Standard<br>EMI filter<br>Standard—Thru Frame 9<br>Input phase loss protection<br>Standard<br>Input overvoltage protection<br>Standard<br>Line surge protection<br>Optional<br>Output short-circuit protection<br>Standard<br>Output ground fault protection<br>Standard<br>Output phase protection<br>Standard<br>Overtemperature protection<br>Standard<br>DC overvoltage protection<br>Standard<br>Drive overload protection<br>Standard<br>Motor overload protection<br>Standard<br>Programmer software<br>Optional<br>Local/remote keypad<br>Standard<br>Keypad lockout<br>Standard<br>Fault alarm output<br>Standard<br>Built-in diagnostics<br>Standard|**Description**<br>**NEMA Type 12/IP54 or NEMA Type 3R**<br>**Specification**|
|---|---|
||**Input/Output Interface Features**|
||Setup adjustment provisions|
||Remote keypad/display<br>Standard|
||Personal computer<br>Standard|
||Operator control provisions|
||Drive mounted keypad/display<br>Standard|
||Remote keypad/display<br>Standard|
||Conventional control elements<br>Standard|
||Serial communications<br>Optional|
||115 Vac control circuit<br>Optional|
||Speed setting inputs|
||Keypad<br>Standard|
||0–10 Vdc potentiometer/voltage signal<br>Standard|
||4–20 mA isolated<br>Configurable|
||4–20 mA differential<br>Configurable|
||Analog outputs|
||Speed/frequency<br>Standard|
||Torque/load/current<br>Programmable|
||Motor voltage<br>Programmable|
||Kilowatts<br>Programmable|
||0–10 Vdc signals<br>Configurable w/jumpers|
||4–20 mA DC signals<br>Standard|
||Isolated signals<br>Optional|
||Discrete outputs|
||Fault alarm<br>Standard|
||Drive running<br>Standard|
||Drive at set speed<br>Programmable|
||Optional parameters<br>14|
||Dry contacts<br>1 (2 relays Form C)|
||Open collector outputs<br>1|
||Additional discrete outputs<br>Optional|
||Communications|
||RS-232<br>Standard|
||RS-422/485<br>Optional|
||DeviceNet™<br>Optional|
||Modbus RTU<br>Optional|
||CANopen (slave)<br>Optional|
||PROFIBUS-DP<br>Optional|
||Lonworks®<br>Optional|
||Johnson Controls Metasys™ N2<br>Optional|
||EtherNet/IP<br>Optional|
||Modbus TCP<br>Optional|
||BACnet<br>Optional|
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-121**
Adjustable Frequency Drives
2.5
SVX9000 Drives
**2**
## **9000X VFD Pump Panels, continued**
||**NEMA Type 12/IP54 or NEMA Type 3R**|
|---|---|
|**Description**<br>**Performance Features**|**Specification**|
|Sensorless vector control|Standard|
|Volts/hertz control|Standard|
|IR and slip compensation|Standard|
|Electronic reversing<br>Dynamic braking|Standard<br>Optional1|
|DC braking|Standard|
|PID setpoint controller|Programmable|
|Critical speed lockout|Standard|
|Current (torque) limit|Standard|
|Adjustable acceleration/deceleration|Standard|
|Linear or S curve accel/decel<br>Jog at preset speed|Standard<br>Standard|
|Thread/preset speeds|7 Standard, 15 Optional|
|Automatic restart|Selectable|
|Coasting motor start|Standard|
|Coast or ramp stop selection|Standard|
|Elapsed time meter|Optional|
|Carrier frequency adjustment<br>**Standard Conditions for Application**|1–16 kHz<br>**and Service**|
|Operating ambient temperature|0 to 40°C|
|Storage temperature|–40 to 60°C|
|Humidity (maximum), non-condensing|95%|
|Altitude (maximum without derate)<br>Line voltage variation|3300 ft (1000m)<br>+10/–15%|
|Line frequency variation|45–66 Hz|
|Efficiency|>96%|
|Power factor (displacement)|0.96|
## **Standard I/O Specifications**
|**Description**|**Specification**|
|---|---|
|Six–digital input|24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V,Ri>5 kohms|
|programmable||
|Two–analog input|Voltage: 0–±10V, Ri>200 kohms|
|configurable w/jumpers|Current: 0 (4)–20 mA, Ri= 250 ohms|
|Two–digital output|Form C relays 250 Vac|
|programmable|30 Vdc 2 amp resistive|
|One–analog output|0–20 mA, RLmax. 500 ohms 10 bits ±2%|
|programmable||
|configurable w/jumper||
|One digital output|Open collector 48 Vdc 50 mA|
|programmable||
## **I/O Specifications for Control/Communication Options**
|**Description**|**Specification**||
|---|---|---|
|Analog voltage, input|0–±10V, Ri ><br>~~2~~00 kohms||
|Analog current, input|0 (4)–20 mA, Ri=|250 ohms|
|Digital input|24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V, Ri>5 kohms||
|Auxiliary voltage|24V (±20%), max. 50 mA||
|Reference voltage|10V ±3%, max. 10 mA||
|Analog current, output|0 (4)–20 mA, RL=|500 kohms, resolution|
||10 bit, accuracy <<br>~~±~~2%||
|Analog voltage, output|0 (2)–10V, RL ><br>~~1~~k|kohms, resolution 10 bit,|
||accuracy <<br>±2%||
|Relay output|||
|Maximum switching voltage|300 Vdc, 250 Vac||
|Maximum switching load|8A/24 Vdc, 0.4A/300 Vdc, 2 kVA/250 Vac||
|Maximum continuous load|2A rms||
|Thermistor input|Rtrip= 4.7 kohms||
## _**Note**_
> 1 Some horsepower units include dynamic braking chopper as standard—refer to individual drive sections.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-122**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Wiring Diagrams**
## **A9 Board Control Wiring**
**==> picture [225 x 243] intentionally omitted <==**
**----- Start of picture text -----**<br>
Basic I/O<br>+10Vref 1<br>Board A9<br>AI1 [+] 2 Input Reference<br>(Voltage)<br>GND 3<br>AI2 [+] 4 Input Reference<br>AI2- 5 (Current)<br>24Vout 6 Control Voltage Output<br>GND 7<br>DIN1 8<br>DIN2 9<br>DIN3 10 24V<br>CMA 11 GND<br>24Vout 12<br>GND 13<br>DIN4 14<br>DIN5 15<br>DIN6 16 24V<br>GND<br>CMB 17<br>AO1 [+] 18 0 (4)/20 mA<br>AO1- 19 RL<500 W<br>DO1 20 + V<+48V<br>I<50 mA<br>Indicates Connections for Inverted Signals<br>**----- End of picture text -----**<br>
## **A2 Board Control Wiring**
**==> picture [226 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
Basic Relay<br>Board A2 RO1/1 21<br>RO1/2 22<br>R L<br>RO1/3 23 AC / DC<br>RO2/1 24 Max. Current/Voltage<br>Switching:<br>RO2/2 25 <8A / 24 Vdc<br><0.4A / 300 Vdc<br>RO2/3 26 <2 kVA / 250 Vac<br>Continuously <2 Arms<br>**----- End of picture text -----**<br>
## **SVX9000 Pump Panel Bypass Power Wiring**
**==> picture [189 x 322] intentionally omitted <==**
**----- Start of picture text -----**<br>
Incoming Power<br>L1 L2 L3<br>Bypass<br>Circuit<br>Breaker<br>Optional Fuse<br>L1 L2 L3<br>To Drive Input<br>To Drive Output<br>U(T1) V(T2)W(T3)<br>Output Bypass<br>Contactor Contactor<br>Overload<br>Relay<br>V(T2)<br>U(T1) W(T3)<br>Motor<br>**----- End of picture text -----**<br>
## **SVX9000 Pump Panel Disconnect Power Wiring**
**==> picture [192 x 255] intentionally omitted <==**
**----- Start of picture text -----**<br>
Incoming Power<br>L1 L2 L3<br>Circuit<br>Breaker<br>Optional Fuse<br>To Drive Input<br>To Drive Output<br>U(T1) V(T2)W(T3)<br>Optional<br>Output<br>Contactor<br>V(T2)<br>U(T1) W(T3)<br>Motor<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-123**
Adjustable Frequency Drives
2.5
SVX9000 Drives
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2**
## _**SVX9000 Pump Application Drives**_
## **Enclosure Box A NEMA Type 12/IP54**
**==> picture [338 x 206] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.00 (101.6) 3.00 (76.2)<br>Minimum Free Air Minimum Air<br>Space Required Space<br>Required<br>Both Sides<br>H1 H2 H<br>0.44 (11.2)<br>Mounting<br>Holes<br>W1 (4 Places)<br>W D1 D<br>**----- End of picture text -----**<br>
|**Voltage**|**hp**|**hp**||||||||**Approx.**<br>**Weight**|**Approx.**<br>**Shipping Weight**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|**AC**|**(IH)**|**(IL)**|**H**|**H1**|**H2**|**W**|**W1**|**D**|**D1**|**Lbs (kg)**|**Lbs (kg)**|
|**Three-Phase**||||||||||||
|208V<br>230V|3/4–10<br>3/4–10|1–15<br>1–15|29.00<br>(736.6)|27.00<br>(685.8)|25.35<br>(643.9)|16.92<br>(429.8)|15.30<br>(388.6)|16.26<br>(413.0)|2.34<br>(59.4)|120 (54)|160 (73)|
|480V|1–25|1–30||||||||||
|**Single-Phase**||||||||||||
|230V|—|3/4–10|29.00|27.00|25.35|16.92|15.30|16.26|2.34|120 (54)|160 (73)|
|480V|—|3/4–20|(736.6)|(685.8)|(643.9)|(429.8)|(388.6)|(413.0)|(59.4)|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-124**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Box B NEMA Type 12/IP54**
**2**
|||4.00 (101.6)<br>Minimum Free Air<br>Space Required|4.00 (101.6)<br>Minimum Free Air<br>Space Required|4.00 (101.6)<br>Minimum Free Air<br>Space Required|<br>0.44<br>Mo<br>H<br>(4 P|<br>0.44<br>Mo<br>H<br>(4 P|<br>0.44<br>Mo<br>H<br>(4 P|<br>0.44<br>Mo<br>H<br>(4 P||**D**<br>**D1**<br>**Approx.**<br>**Weight**<br>**Lbs (kg)**<br>**Approx.**<br>**Shipping Weight**<br>**Lbs (kg)**<br>H|**D**<br>**D1**<br>**Approx.**<br>**Weight**<br>**Lbs (kg)**<br>**Approx.**<br>**Shipping Weight**<br>**Lbs (kg)**<br>H|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||<br><br>s<br>D1||||||
|H2<br>H1||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
||||||||D1|||||
|||W1<br>W|||||||D|||
|||||||||||||
|||||||||||||
|||||||||||||
|**Voltage**<br>**AC**|||||||||**W**<br>**W1**<br>|||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||**hp**<br>**(IH)**<br>**hp**<br>**(IL)**||**H**||||||||
|**Three-Phase**||||||||||||
|208V<br>15–25<br>20–30||||40.00<br>(1016.|0)<br>38.00<br>(965.2)<br>36.35<br>(923.3)||||20.92<br>(531.4)<br>19.30<br>(490.2)|16.76<br>(425.7)<br>2.34<br>(59.4)<br>185 (84)<br>229 (104)||
|230V<br>15–25<br>20–30||||||||||||
|480V<br>30–60<br>40–75||||||||||||
|**Single-Phase**||||||||||||
|230V<br>—<br>15–20||||40.00<br>(1016.|0)<br>38.00<br>(965.2)<br>36.35<br>(923.3)||||20.92<br>(531.4)<br>19.30<br>(490.2)|16.76<br>(425.7)<br>2.34<br>(59.4)<br>185 (84)<br>229 (104)||
|480V<br>—<br>25–30||||||||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-125**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Box C NEMA Type 12/IP54**
|<br>|<br>|<br> <br>|<br> <br>|<br> <br>|<br> <br>||||||
|---|---|---|---|---|---|---|---|---|---|---|
|0.44 (11.2<br>Mountin<br>Holes<br>||H<br>0.44<br>Mou<br>Ho<br>(4 Pl<br>3.00 (76.2)<br>Minimum Air Space<br>Required Both Sides<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>H<br>D1<br>W<br>W1<br>D<br>)<br>g<br>)|||(11.2)<br>nting<br>les<br>aces)|4.00 (101.6) Minimum<br>Free Air Space Required<br>W1|||||
|(4 Places||<br>)|||||||||
||||||||||||
|H2<br>H1|||||H2<br>4||||||
||||||||||||
|||W|1||||W||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
||||||||||||
|**Voltage**<br>**AC**||**hp**<br>**(IH)**<br>**hp**<br>**(IL)**<br>**H**<br>**H1**||**H2**<br>**H3**|**H4**|**W**<br>**W1**|||||
|**Three-Phase**|||||||||||
|208V<br>30–50<br>40–60<br>52.00<br>(1320.8)<br>50.00<br>(1270.0)<br>48.35<br>(1228.1)<br>72.00<br>(1828.8)<br>230V<br>30–50<br>40–60<br>480V<br>75–125<br>100–150|||||71.19<br>(1808.2)|30.92<br>(785.4)<br>29.30<br>(744.2)<br>16.78<br>(426.2)<br>2.34<br>(59.4)<br>1|||||
|**Single-Phase**|||||||||||
|230V<br>—<br>25–40<br>52.00<br>(1320.8)<br>50.00<br>(1270.0)<br>48.35<br>(1228.1)<br>72.00<br>(1828.8)<br>480V<br>—<br>40–60|||||71.19<br>(1808.2)|30.92<br>(785.4)<br>29.30<br>(744.2)<br>16.78<br>(426.2)<br>2.34<br>(59.4)<br>1|||||
_**Note**_
> 1 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-126**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Box A NEMA Type 3R**
**==> picture [334 x 274] intentionally omitted <==**
**----- Start of picture text -----**<br>
W D<br>H<br>H1 H2 H3<br>W2<br>W3 W1 D2 D1<br>0.44 (11.2)<br>Mounting<br>Holes<br>(4 Places)<br>**----- End of picture text -----**<br>
**2**
|||||||||||||||**Approx.**|**Approx.**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Voltage**|**hp**|**hp**||||||||||||**Weight**|**Shipping Weight**|
|**AC**|**(IH)**|**(IL)**|**H**|**H1**|**H2**|**H3**|**W**|**W1**|**W2**|**W3**|**D**|**D1**|**D2**|**Lbs (kg)**|**Lbs (kg)**|
|**Three-Phase**||||||||||||||||
|208V|3/4–10|1–15|33.00|31.36|29.67|25.35|21.05|16.92|15.30|2.07|17.24|16.26|3.31|170 (77)|215 (98)|
|230V|3/4–10|1–15|(838.2)|(796.5)|(753.6)|(643.9)|(534.7)|(429.8)|(388.6)|(52.6)|(437.9)|(413.0)|(84.1)|||
|480V|1–25|1–30||||||||||||||
|**Single-Phase**<br>230V<br>—||3/4–10|33.00|31.36|29.67|25.35|21.05|16.92|15.30|2.07|17.24|16.26|3.31|170 (77)|215 (98)|
|480V|—|3/4–20|(838.2)|(796.5)|(753.6)|(643.9)|(534.7)|(429.8)|(388.6)|(52.6)|(437.9)|(413.0)|(84.1)|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-127**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Box B NEMA Type 3R**
**==> picture [370 x 386] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 W D<br>2<br>2<br>2<br>2<br>2<br>2<br>H2<br>2 H1 H<br>2 H3<br>2<br>2<br>2<br>2<br>2<br>W2<br>2 W3 W1 D2 D1<br>0.44 (11.2)<br>2 Mounting<br>Holes<br>(4 Places)<br>2<br>2<br>**----- End of picture text -----**<br>
|||||||||||||||**Approx.**|**Approx.**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Voltage**|**hp**|**hp**||||||||||||**Weight**|**Shipping Weight**|
|**AC**|**(IH)**|**(IL)**|**H**|**H1**|**H2**|**H3**|**W**|**W1**|**W2**|**W3**|**D**|**D1**|**D2**|**Lbs (kg)**|**Lbs (kg)**|
|**Three-Phase**||||||||||||||||
|208V|15–25|20–30|46.09|44.45|42.77|36.35|26.31|20.92|19.30|2.69|17.74|16.76|3.31|235|290|
|230V<br>480V|15–25<br>30–60|20–30<br>40–75|(1170.7)|(1129.0)|(1086.4)|(923.3)|(668.3)|(531.4)|(490.2)|(68.3)|(450.6)|(425.7)|(84.1)|(107)|(132)|
|**Single-Phase**||||||||||||||||
|230V|—|15–20|46.09|44.45|42.77|36.35|26.31|20.92|19.30|2.69|17.74|16.76|3.31|235|290|
|480V|—|25–30|(1170.7)|(1129.0)|(1086.4)|(923.3)|(668.3)|(531.4)|(490.2)|(68.3)|(450.6)|(425.7)|(84.1)|(107)|(132)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-128**
Adjustable Frequency Drives
2.5
SVX9000 Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Box C NEMA Type 3R**
||||0.44 (11.2)<br>Mounting Holes<br>(4 Places)<br>H<br>W2<br>W1<br>W3<br>D2<br>D1<br>W<br>D<br>H|||W<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|W<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|W<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|W<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|
|---|---|---|---|---|---|---|---|---|---|
||||W2<br>W1<br>W|||W2|D|||
|H1|H3<br>H2|||H3<br>H2<br>5|||||H|
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||||||
|||||||D2<br>D1<br>W1||||
|**Voltage**<br>**AC**<br>**hp**<br>**(IH)**<br>**hp**<br>**(IL)**|||**H**<br>**H1**<br>**H2**<br>**H3**<br>**H4**<br>**H5**<br>|**W**<br>**W1**<br>**W2**||||||
|**Three-Phase**||||||||||
|208<br>30–50<br>40–60|||58.09<br>(1475.5)<br>56.45<br>(1433.8)<br>54.77<br>(1391.2)<br>48.35<br>(1228.1)<br>78.09<br>(1983.5)<br>77.64<br>(1972.1)<br>3<br>(|7.73<br>958.3)<br>30.92<br>(785.4)<br>29.30<br>(744.2)||3.34<br>(84.8)<br>17.74<br>(450.6)<br>16.77<br>(426.0)<br>3.31<br>(84.1)<br>1||||
|230<br>30–50<br>40–60||||||||||
|480<br>75–125<br>100–150||||||||||
|**Single-Phase**||||||||||
|230V<br>—<br>25–40|||58.09<br>(1475.5)<br>56.45<br>(1433.8)<br>54.77<br>(1391.2)<br>48.35<br>(1228.1)<br>78.09<br>(1983.5)<br>77.64<br>(1972.1)<br>3<br>(|7.73<br>958.3)<br>30.92<br>(785.4)<br>29.30<br>(744.2)||3.34<br>(84.8)<br>17.74<br>(450.6)<br>16.77<br>(426.0)<br>3.31<br>(84.1)<br>1||||
|480V<br>—<br>40–60||||||||||
**2**
## _**Note**_
> 1 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-129**
Adjustable Frequency Drives
SVX9000 Drives
## 2.5
Approximate Dimensions in Inches (mm)
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**Enc**<br>**H**<br>93.58<br>(2376|**losure Size F**<br>W|**losure Size F**<br>W|||**D**<br>**D1**<br>**Approximate**<br>**Weight**<br>**Lbs (kg)**<br>**Approximate**<br>**Shipping Weight**<br>**Lbs (kg)**<br>D<br>D1<br>H<br>H1|
|---|---|---|---|---|---|
|||||||
||||||H<br>H1|
|||||||
|||||||
||W1|||||
|||||||
|||||||
|||||||
|||||||
||**H1**<br>**W**|||**W1**||
||.9)<br>69.51<br>(1765.60)<br>60.00<br>(1524.0)|||48.00<br>(1219.2)<br>37.50<br>(952.5)<br>26.00<br>(660.4)<br>1700 (771)<br>1850 (839)||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-130**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **H-Max Series Drives**
## **Contents**
|**Contents**||**2**|
|---|---|---|
|**_Description_**|**_Page_**|**2**|
|H-Max Series Drives||**2**|
|H-Max Drives . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-132**||
|H-Max IntelliPass and||**2**|
|IntelliDisconnect Drives . . . . . . . . . . . . . . . . .|**V6-T2-141**||
## **Product Overview**
## **H-Max Family Introduction**
Eaton’s H-Max™ Series VFD is the next generation of drives specifically engineered for HVAC pump and fluid control applications. The H-Max family of products boasts industry leading energy efficiency algorithms for your applications. Not only are the drives ultra-efficient— they contain software that minimizes motor winding energy loses in your applications. Designed for easy installation, simple startup, and long life; the H-Max Series drive family provides exceptional value to our customers,
## _**Product Range**_
## **Open Style Drives:**
- 0.75–125 hp at 230 Vac
- 1.5–250 hp at 480 Vac
**Note:** Available in NEMA 1 or NEMA 12 designs.
## **IntelliPass/IntelliDisconnect**
## **Drives:**
- 1–30 hp at 208 Vac
- 1–30 hp at 230 Vac
> ● 1–75 hp at 480 Vac
**Note:** Available in NEMA 1, NEMA 12, or NEMA 3R enclosures.
## **Application Description**
## **Key Feature**
The H-Max Series drive was _**Active Energy Control Algorithm**_ designed specifically for Eaton’s H-Max Series drives HVAC pump and fluid control have been designed to provide applications. It is intended to industry leading energy saving be used on variable torque solutions. Not only is the loads with the intent of moving drive ultra-efficient, the drive air or liquids. With this in mind, seeks the most efficient the H-Max drive has onboard operating point of the motor, I/O pre-programmed to meet minimizing energy loss in the the common needs for these windings per the given load applications. The H-Max drive requirements. This is an supports items such as Eaton protected control standard speed control, algorithm exclusive to PID functionality, as well as H-Max drives. multi-motor applications. The drive easily supports interlock, second motor parameter set, as well as fire mode functionality.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-131**
Adjustable Frequency Drives
2.6
H-Max Series Drives
**2**
## **H-Max Drives**
## **Contents**
## _**Description**_
|**Contents**<br>**_Description_**||
|---|---|
|**_Description_**|**_Page_**|
|H-Max Drives||
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V6-T2-133**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-134**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-137**|
|Replacement Parts . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-137**|
|Technical Data and Specifications . . . . . . . . . .|**V6-T2-138**|
|Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-139**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-140**|
|H-Max IntelliPass and IntelliDisconnect Drives . . .|**V6-T2-141**|
## **H-Max Drives**
## **Product Description**
Eaton’s H-Max Series VFD has software and hardware designed specifically for the HVAC, pump industry. The ultra-efficient DC capacitor and power structure allows the drive to consume less energy, lowering greenhouse gases.
The I/O configuration is designed with wiring ergonomics in mind by including removable terminal blocks. The main, easily removable, control board used for all drive frames with six digital IN, two analog IN, one analog OUT, three relay OUT accepts two additional I/O or communication board. In addition, the control board has built-in RS-485 and Ethernet communication.
These drives continue the tradition of robust performance, and raise the bar on features and functionality, ensuring the best solution at the right price.
In addition to the Active Energy Control Algorithm to maximize motor efficiency, the drive boasts an ultraefficient DC capacitor and power structure to allow less energy consumption, lowering greenhouse gases.
## **Features and Benefits**
## _**Hardware**_
- Thin metal capacitor design—ultra-efficient drive operation and extended self life (up to five years without reforming)
- Integrated 5% DC link choke with Input surge protection—protects against voltage spikes and provides a clean wave form to the motor
- EMI/RFI filters standard on all drives—meets EMC Category 2 for commercial applications
- Real-time clock—supports calendaring and PLC functionality
- Graphic LCD display and keypad—supports simple menu navigation as well as on-screen diagnostics and troubleshooting
- HAND-OFF-AUTO and drive-bypass selector on keypad—simplifies control
- Standard I/O: 6DI, 2AI, 1AO, 2 Form C RO (NO/ NC), 1 Form A RO (NO)— supports requirements for most installations
- Onboard RS 485: Modbus, N2, BACnet—meets needs of most communication requirements
- Onboard Ethernet: BACnet/ IP, Modbus/TCP—meets needs of most communication requirements
- Two expansion slots— intended to support additional I/O or communication protocols as necessary
- Quick disconnect terminals for I/O connections— supports fast easy installation
## _**Software**_
- Active energy control— minimizes energy losses in your motor resulting in industry leading energy efficiency for your application
- Quick Start Wizard upon initial power up—supports fast easy installation
- Copy/paste functionality on drive keypad—allows for fast setup of multiple drives
- Pre-programmed I/O— supports fast easy installation for most applications
## **Standards and Certifications**
## _**Product**_
- IEC 61800-5-1
- CE
- UL508C
- cUL
- C-Tick Mark
- OSHPD Seismic Certified
- Plenum Rated
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-132**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Catalog Number Selection**
## **H-Max Series Drives**
**2**
**==> picture [456 x 311] intentionally omitted <==**
**----- Start of picture text -----**<br>
-<br>HMX 3 4 A G 3D4 2 1 N<br>Product Braking/Application<br>HMX = HVAC drive N = No brake chopper (low overload)<br>Phase<br>3 = Three-phase Enclosure<br>1 = Open NEMA Type 1 IP21<br>2 = Open NEMA Type 12 IP54<br>Voltage<br>2 = 200–240V<br>4 = 380–480V Input Options Frame and<br>Voltage Specific<br>2 = EMC C2<br>Software Series<br>A–Z<br>Keypad<br>G = Graphical panel<br>Amperes<br>200–240 Volts 380–480 Volts<br>3D7 = 3.7A–0.75 hp, 0.55 kW 062 = 62A–20 hp, 15 kW 3D4 = 3.4A–1.5 hp, 1.1 kW 046 = 46A–30 hp, 22 kW<br>4D8 = 4.8A–1 hp, 0.75 kW 075 = 75A–25 hp, 18.5 kW 4D8 = 4.8–2 hp, 1.5 kW 061 = 61A–40 hp, 30 kW<br>6D6 = 6.6A–1.5 hp, 1.1 kW 088 = 88A–30 hp, 22 kW 5D6 = 5.6A–3 hp, 2.2 kW 072 = 72A–50 hp, 37 kW<br>8D0 = 8A–2 hp, 1.5 kW 105 = 105A–40 hp, 30 kW 8D0 = 8A–4 hp, 3 kW 087 = 87A–60 hp, 45 kW<br>011 = 11A–3 hp, 2.2 kW 140 = 140A–50 hp, 37 kW 9D6 = 9.6A–5 hp, 4 kW 105 = 105A–75 hp, 55 kW<br>012 = 12A–4 hp, 3 kW 170 = 170A–60 hp, 45 kW 012 = 12A–7.5 hp, 5.5 kW 140 = 140A–100 hp, 75 kW<br>018 = 18A–5 hp, 4 kW 205 = 205A–75 hp, 55 kW 016 = 16A–10 hp, 7.5 kW 170 = 170A–125 hp, 90 kW<br>024 = 24A–7.5 hp, 5.5 kW 261 = 261A–100 hp, 75 kW 023 = 23A–15 hp, 11 kW 205 = 205A–150 hp, 110 kW<br>031 = 31A–10 hp, 7.5 kW 310 = 310A–125 hp, 90 kW 031 = 31A–20 hp, 15 kW 261 = 261A–200 hp, 132 kW<br>048 = 48A–15 hp, 11 kW 038 = 38A–25 hp, 18.5 kW 310 = 310A–250 hp, 160 kW<br>**----- End of picture text -----**<br>
## _**Notes**_
All boards are varnished (conformed coated). Corrosion resistant. Battery included in all drives for real-time clock. Keypad kit includes HOA bypass. Keypad kit includes HOA, back reset for Europe application. EMI/RFI filters included.
DC link choke included.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-133**
Adjustable Frequency Drives
2.6
## H-Max Series Drives
## **Product Selection**
## _**H-Max Series Drives—230 Vac**_
**2**
**NEMA Type 1**
## **NEMA Type 1/IP21**
**==> picture [414 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|FS|Drive Output Current|Assigned Motor Ratings|
|Frame|Low Overload Full|Drive kW|230 Vac|Low Overload Full|Catalog|
|Size|Load Amps at 40°C|Horsepower|230 Vac/50 Hz|NEC Amps|[1]|Load Amps at 50°C|Number|
|SSS|
|4|3.7|0.75|0.55|3.2|2.6|HMX32AG3D721-N|
|4.8|1|0.75|4.2|3.7|HMX32AG4D821-N|
|TT|6.6|1.5|1.1|6.6|4.8|HMX32AG6D621-N|
|8|2|1.5|6.8|6.6|HMX32AG8D021-N|
|11|3|2.2|9.6|8|HMX32AG01121-N|
|12.5|4|3|N/A|11|HMX32AG01221-N|
|5|18|5|4|15.2|12.5|HMX32AG01821-N|
|24|7.5|5.5|22|18|HMX32AG02421-N|
|31|10|7.5|28|24|HMX32AG03121-N|
|6|48|15|11|42|31|HMX32AG04821-N|
|62|20|15|54|48|HMX32AG06221-N|
|7|75|25|18.5|68|62|HMX32AG07521-N|
|88|30|22|80|75|HMX32AG08821-N|
|105|40|30|104|88|HMX32AG10521-N|
|8|140|50|37|130|105|HMX32AG14021-N|
|170|60|45|154|140|HMX32AG17021-N|
|205|75|55|192|170|HMX32AG20521-N|
|9|261|100|75|248|205|HMX32AG26121-N|
|310|125|90|N/A|261|HMX32AG31021-N|
**----- End of picture text -----**<br>
## **NEMA Type 12**
## **NEMA Type 12/IP54**
**==> picture [413 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|FS|Drive Output Current|Assigned Motor Ratings|
|Frame|Low Overload Full|Drive kW|230 Vac|Low Overload Full|Catalog|
|Size|Load Amps at 40°C|Horsepower|230 Vac/50 Hz|NEC Amps|[1]|Load Amps at 50°C|Number|
|SS|
|4|3.7|0.75|0.55|3.2|2.6|HMX32AG3D722-N|
|TTT|4.8|1|0.75|4.2|3.7|HMX32AG4D822-N|
|6.6|1.5|1.1|6.6|4.8|HMX32AG6D622-N|
|8|2|1.5|6.8|6.6|HMX32AG8D022-N|
|11|3|2.2|9.6|8|HMX32AG01122-N|
|12.5|4|3|N/A|11|HMX32AG01222-N|
|5|18|5|4|15.2|12|HMX32AG01822-N|
|24|7.5|5.5|22|18|HMX32AG02422-N|
|31|10|7.5|28|24|HMX32AG03122-N|
|6|48|15|11|42|31|HMX32AG04822-N|
|62|20|15|54|48|HMX32AG06222-N|
|7|75|25|18.5|68|62|HMX32AG07522-N|
|88|30|22|80|75|HMX32AG08822-N|
|105|40|30|104|88|HMX32AG10522-N|
|8|140|50|37|130|105|HMX32AG14022-N|
|170|60|45|154|140|HMX32AG17022-N|
|205|75|55|192|170|HMX32AG20522-N|
|9|261|100|75|248|205|HMX32AG26122-N|
|310|125|90|N/A|261|HMX32AG31022-N|
**----- End of picture text -----**<br>
## _**Note**_
1 For sizing reference.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-134**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## _**H-Max Series Drives—480 Vac**_
## **NEMA Type 1**
## **NEMA Type 12**
## **NEMA Type 1/IP21**
||**NEMA Type 1/IP21**|**NEMA Type 1/IP21**||||||
|---|---|---|---|---|---|---|---|
||**FS**|**Drive Output Current**||**Assigned Motor Ratings**|**Assigned Motor Ratings**|||
|**Frame**<br>**Size**<br>4<br>~~— —~~<br>~~_—~~||**Low Overload Full**<br>**Load Amps at 40°C**<br>3.4<br>4.8<br>~~_—~~<br>~~OO~~|**480 Vac**<br>**NEC Amps**1<br>**Catalog**<br>**Number**<br>**Horsepower**<br>**Drive kW**<br>**400 Vac/50 Hz**<br>**Low Overload Full**<br>**Load Amps at 50°C**<br>1.5<br>1.1<br>2.1<br>2.6<br>**HMX34AG3D421-N**<br>2<br>1.5<br>3.4<br>3.4<br>**HMX34AG4D821-N**<br>~~_—~~|||||
|||5.6<br>3<br>2.2<br>5.6<br>4.8<br>**HMX34AG5D621-N**<br>8.0<br>4<br>3.0<br>N/A<br>5.6<br>**HMX34AG8D021-N**<br>~~TOT~~<br>~~<<~~||||||
|||9.6|5|4|7.6|8|**HMX34AG9D621-N**|
|||12|7.5|5.5|11|9.6|**HMX34AG01221-N**|
||5|16|10|7.5|14|12|**HMX34AG01621-N**|
|||23|15|11|21|16|**HMX34AG02321-N**|
|||31|20|15|27|23|**HMX34AG03121-N**|
||6|38|25|18.5|34|31|**HMX34AG03821-N**|
|||46|30|22|40|38|**HMX34AG04621-N**|
|||61|40|30|52|46|**HMX34AG06121-N**|
||7|72|50|37|65|61|**HMX34AG07221-N**|
|||87<br>105|60<br>75|45<br>55|77<br>96|72<br>87|**HMX34AG08721-N**<br>**HMX34AG10521-N**|
||8|140<br>170|100<br>125|75<br>90|124<br>156|105<br>140|**HMX34AG14021-N**<br>**HMX34AG17021-N**|
|||205|150|110|180|170|**HMX34AG20521-N**|
||9|261|200|132|240|205|**HMX34AG26121-N**|
|||310|250|160|302|261|**HMX34AG31021-N**|
||**NEMA Type 12/IP54**|**NEMA Type 12/IP54**||||||
||**FS**|**Drive Output Current**||**Assigned Motor Ratings**|**Assigned Motor Ratings**|||
||**Frame**|**Low Overload Full**||**Drive kW**|**480 Vac**|**Low Overload Full**|**Catalog**|
|**Size**<br>4<br>—~~—~~||**Load Amps at 40°C**<br>3.4<br>4.8|**Horsepower**<br>1.5<br>2<br>~~_—~~|**400 Vac/50 Hz**<br>1.1<br>1.5<br>~~_—~~|**NEC Amps**1<br>**Number**<br>**Load Amps at 50°C**<br>2.1<br>2.6<br>**HMX34AG3D422-N**<br>3.4<br>3.4<br>**HMX34AG4D822-N**<br>~~_—~~|||
|||5.6|3|2.2|5.6|4.8|**HMX34AG5D622-N**|
|||8.0|4|3.0|N/A|5.6|**HMX34AG8D022-N**|
|||9.6|5|4|7.6|8|**HMX34AG9D622-N**|
|||12|7.5|5.5|11|9.6|**HMX34AG01222-N**|
||5|16<br>23|10<br>15|7.5<br>11|14<br>21|12<br>16|**HMX34AG01622-N**<br>**HMX34AG02322-N**|
||6|31<br>38|20<br>25|15<br>18.5|27<br>34|23<br>31|**HMX34AG03122-N**<br>**HMX34AG03822-N**|
|||46|30|22|40|38|**HMX34AG04622-N**|
|||61|40|30|52|46|**HMX34AG06122-N**|
||7|72|50|37|65|61|**HMX34AG07222-N**|
|||87|60|45|77|72|**HMX34AG08722-N**|
|||105|75|55|96|87|**HMX34AG10522-N**|
||8|140|100|75|124|105|**HMX34AG14022-N**|
|||170|125|90|156|140|**HMX34AG17022-N**|
|||205|150|110|180|170|**HMX34AG20522-N**|
||9|261|200|132|240|205|**HMX34AG26122-N**|
|||310|250|160|302|261|**HMX34AG31022-N**|
**2**
## _**Note**_
1 For sizing reference.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-135**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## _**Onboard Network Communications**_
## **Johnson Controls 2 Metasys N2**
H-Max Series provides communication between the drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. N2 can be selected and programmed by the drive keypad.
## **BACnet**
H-Max Series provides communication to BACnet networks. Data transfer is master-slave/token passing (MS/TP) RS-485.
## **BACnet IP**
100Base-T interface.
## **Modbus TCP**
## **Modbus RTU**
H-Max Series provides communication to Modbus RTU RS-485 as a slave on a Modbus network. Other communication parameters include an address range from 1–247; a parity of None, Odd or Even; and the stop bit is 1.
Ethernet based protocol.
## _**H-Max Series Option Board Kits Available for Slot B**_
The factory issued relay option board can be replaced with the following option
boards to customize the drive for your application needs.
The standard board provides 2 Form C RO (NO/NC) and 1 Form A RO (NO).
## **Option Boards Mounted in Slot B**
**Option Kit Option Kit Description Catalog Number** I/O expander card, 2 RO and thermistor input **Relay Board 2**
## _**H-Max Series Option Board Kits Available for Slots D and E**_
The H-Max Series drives can application needs. The drive’s accommodate a wide control unit is designed to selection of expander and accept a total of two option adapter option boards to boards. customize the drive for your
The H-Max Series factoryinstalled standard board configuration includes an I/O board and a relay output board.
## **Option Boards Mounted in Slots D and E**
||**Option Kit**|
|---|---|
|**Option Kit Description**|**Catalog Number**|
|6 x DI /DO, each digital input can be individually programmed as digital output|**XMX-IO-B1-A**|
|1RO Form C (NO/NC), 1RO Form A (NO), 1 thermistor<br>1 x AI, 2 x AO (isolated)|**XMX-IO-B2-A**<br>**XMX-IO-B4-A**|
|3 x RO Form A (NO)|**XMX-IO-B5-A**|
|1RO Form A (NO), 5DI 42–240 Vac input|**XMX-IO-B9-A**|
|1 x AO, 1 x DO, 1 x RO|**XMX-IO-BF-A**|
|LonWorks®|**XMX-COM-C4-A**|
## _**NEMA Type 1 to NEMA Type 12/IP54 Conversion Kit**_
The NEMA Type 12/IP54 Kit consists of a drive cover, option kit is used to convert a fan kit and plugs. NEMA Type 1 to a NEMA Type 12 drive.
## **NEMA Type 12/IP54 Cover**
||**Option Kit**|
|---|---|
|**Option Kit Description**|**Catalog Number**|
|FS4-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos|**FS4-N12KIT**|
|FS5-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos|**FS5-N12KIT**|
|FS6-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos|**FS6-N12KIT**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-136**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Accessories**
## _**Flange Kits**_
The flange kit is used when the power section heat sink is mounted through the back panel of an enclosure.
## **Flange Kit NEMA Type 12/IP54**
Includes flange, mounting brackets, NEMA Type 12 fan components, air shroud screws and plugs.
## **Replacement Parts**
## **Control Board/Keypad**
|**Control Board/Keypad**||
|---|---|
||**Current Catalog**|
|**Description**<br>H-Max Series graphic bypass, HOA|**Number**<br>**KeypadbypassHOA**|
|H-Max Series graphic back, HOA|**KeypadbackHOA**|
**2**
## **PC Cable**
## **Frames FS4–FS7**[12]
|**Frames FS4–FS7**12||
|---|---|
||**Catalog**|
|**Description**|**Number**|
|**NEMA Type 12/IP54**||
|FS4 N12/IP54 flange kit|**FS4-Flange-N12KIT**|
|(mounting N1 drive into N12 enclosure)||
|FS5 N12/IP54 flange kit|**FS5-Flange-N12KIT**|
|(mounting N1 drive into N12 enclosure)||
|FS6 N12/IP54 flange kit|**FS6-Flange-N12KIT**|
|(mounting N1 drive into N12 enclosure)||
|FS7 N12/IP54 flange kit|**FS7-Flange-N12KIT**|
|(mounting N1 drive into N12 enclosure)||
## _**Keypad Accessories**_
## **Remote Mounting Keypad Kit**
## **Frames FS4–FS9**
|**Frames FS4–FS9**||
|---|---|
||**Catalog**|
|**Description**|**Number**|
|Remote mounting keypad kit—bezel and cable|**OPTRMT-BP-HMAX**|
## _**Drive Demo**_
## **H-Max Series Drive Demo**
## **Demos and Power Supply**
|**PC Cable**||
|---|---|
||**Catalog**|
|**Description**|**Number**|
|Remote download USB to RJ-45 cable with|**REM-USB-Down**|
|software driver disk||
## **Replacement Relay Board in Slot B**
|**Replacement Relay Board in Slot**|**B**|
|---|---|
||**Catalog**|
|**Description**|**Number**|
|Replacement relay board|**Relay board 1**|
|qty 2 Form C relay, qty 1 Form A relay||
## **Main Fan**
|**Main Fan**||
|---|---|
||**Catalog**|
|**Description**|**Number**|
|FS4 main fan|**FS4-Main Fan**|
|FS5 main fan|**FS5-Main Fan**|
|FS6 main fan<br>FS7 main fan|**FS6-Main Fan**<br>**FS7-Main Fan**|
## **Internal Fan**
|**Internal Fan**||
|---|---|
|**Description**|**Catalog**<br>**Number**|
|FS4 internal fan (IP54/NEMA 12)|**FS4-Internal Fan**|
|FS5 internal fan (IP54/NEMA 12)|**FS5-Internal Fan**|
|FS6 internal fan (IP54/NEMA 12)|**FS6-Internal Fan**|
|FS7 internal fan (IP54/NEMA 12)|**FS7-Internal Fan**|
|**Demos and Power Supply**||
|---|---|
||**Catalog**|
|**Description**|**Number**|
|H-Max Series bypass demo|**H-MAX-BYPASS-DEMO**|
|Hand-held 24V auxiliary power supply—used to supply power|**9000XAUX24V**|
|to the control module in order to perform keypad programming||
|before the drive is connected to line voltage||
## _**Notes**_
> 1 For installation of a NEMA Type 1 drive into a NEMA Type 12 oversized enclosure.
> 2 Frame size 8 and 9 must be ordered from the factory as a flange mount unit.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-137**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Technical Data and Specifications**
|**2**|**Technical Data and Specifications**|**Technical Data and Specifications**|
|---|---|---|
|**2**|**H-Max Series Drives**||
||**Description**|**Specification**|
|**2**|**Input Ratings**||
||Input voltage (Vin)|200–240 Vac, 380–480 Vac, –10%/+10%|
|**2**|Input frequency (fin)|50/60 Hz (variation up to 47–66 Hz)|
|**2**|Connection to power<br>Short-circuit withstand|Once per minute or less (typical operation)<br>100 kAIC|
|**2**|rating<br>**Output Ratings**||
|**2**|Output voltage|0 to Vin/Uinline voltage in|
||Continuous output current|Ambient temperature max. 104°F (40°C)|
|**2**|ILoverload|1.1 x IL(1 min./10 min.)|
||Overload current|110% (1 min./10 min.)|
|**2**|Initial output current|150% for two seconds|
|**2**|Output frequency<br>Frequency resolution|0 to 320 Hz<br>0.01 Hz|
|**2**|**Control Characteristics**||
||Control method|Frequency control (V/f) open loop sensorless vector control|
|**2**|Switching frequency|1–310 amps|
|||FS4–9: default 6 kHz|
|**2**|Frequency reference|Analog input: Resolution 0.1% (10-bit), accuracy ±1%|
|||Panel reference: Resolution 0.01 Hz|
|**2**|Field weakening point|8 to 320 Hz|
||Acceleration time|0.1 to 3000 seconds|
|**2**|Deceleration time|0.1 to 3000 seconds|
|**2**|Braking torque<br>**Ambient Conditions**|DC brake: 30% x Tn|
|**2**|Ambient operating<br>temperature|FS4–FS9: 14°F (–10°C), no frost to 104°F (40°C)<br>(Drive can operate at 122°F (50°C), see**Pages V6-T2-134**and|
|||**V6-T2-135**)|
|**2**|Storage temperature|–40° to 158°F (–40° to 70°C)|
|**2**|Relative humidity<br>Air quality|0 to 95% RH, noncondensing, non-corrosive, no dripping water<br>Chemical vapors: IEC 60721-3-3, unit in operation, Class 3C2;|
|**2**|Altitude|Mechanical particles: IEC 60721-3-3, unit in operation, Class 3S2<br>100% load capacity (no derating) up to 3280 ft (1000m);|
|**2**||1% derating for each 328 ft (100m) above 3280 ft (1000m);<br>max. 9842 ft (3000m); 380–480V|
||Vibration|FS4–FS9: EN 61800-5-1, EN 60068-2-6; 5 to 150 Hz,|
|**2**||displacement amplitude 1 mm (peak) at 5 to 15.8 Hz,<br>max. acceleration amplitude 1G at 15.8 to 150 Hz|
|**2**|Shock|EN 61800-5-1, EN 60068-2-27 UPS Drop test (for applicable UPS<br>weights) Storage and shipping: max. 15G, 11 ms (in package)|
|**2**|Enclosure class|NEMA Type 1/IP21 or NEMA Type 12/IP54<br>(keypad required for IP54/Type 12)|
|**2**|**Standards**||
||EMC|Immunity: Fulfills all EMC immunity requirements;|
|**2**|Emissions|Emissions: EN 61800-3, LEVEL H (EMC C2)<br>EMC level dependent—|
|**2**||+EMC 2: EN61800-3 (2004) Category C2<br>Delivered with Class C2 EMC filtering as default.|
|**Description**|**Specification**|
|---|---|
|**Control Connections**||
|Analog input voltage|0 to 10V, R = 200 kohms differential|
||Resolution 0.1%; Accuracy ±1%|
||DIP switch selection (voltage/current)|
|Analog input current|0(4) to 20 mA; Ri–250 ohms differential|
|Digital inputs (6)|Positive or negative logic; 18 to 30 Vdc|
|Auxiliary voltage|+24V ±10%, max. 250 mA|
|Output reference voltage|+10V +3%, max. load 10 mA|
|Analog output|0–10V, 0(4) to 20 mA; RLmax. 500 ohms;|
||Resolution 10 bit; Accuracy ±2%|
||DIP switch selection (voltage/current)|
|Relay outputs|3 programmable, 2 Form C, 1 Form A relay outputs|
||Switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A|
|Hard wire jumper|Between terminal 6 and 10 factory default|
|DIP switch setting default|RS-485 = off|
||A01 = current|
||A12 = current|
||A11 = voltage|
|**Protections**||
|Overcurrent protection|Yes|
|Overvoltage protection|Yes|
|DC bus regulation anti-trip|Yes (accelerates or decelerates the load)|
|Undervoltage protection|Yes|
|Earth fault protection|Yes (in case of earth fault in motor or motor cable,|
||only the frequency converter is protected)|
|Input phase supervision|Yes (trips if any of the input phases are missing)|
|Motor phase supervision|Yes (trips if any of the output phases are missing)|
|Overtemperature protection|Yes|
|Motor overload protection|Yes|
|Motor stall protection|Yes|
|Motor underload protection|Yes|
|Short-circuit protection|Yes|
|Surge protection|Yes (varistor input)|
|Conformed coated|Yes (prevents corrosion)|
|(varnished) boards||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-138**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Wiring Diagram**
## **Control Input/Output, PID Application**
**==> picture [502 x 496] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ-45 BACnet/IP Ethernet Industrial ProtocolModbus/TCP Transmission Control Protocol (Ethernet Based) DB R+ Optional<br>Optional Chopper R- Resistor<br>Circuit L1 Three-Phase Input 5% DC LinkReactor Three-Phase U (T1)<br>Breaker L2 Input Output V (T2) Motor<br>(Single-Phase not available)<br>L3 W (T3)<br>Slot A<br>Terminal Factory Default Signal<br>Resistor 1 +10V Reference Output<br>2 AI–1+ Analog Input Voltage (Range 0–10 Vdc)(can be programmed to current 4–20 mA)<br>3 Vin Analog Output Common (Ground)<br>Analog Input Current (Range 4–20 mA)<br>4 AI–2+ (can be programmed to voltage 0–10 Vdc)<br>PI Setpoint or Feedback<br>Factory 5 AI–2– Analog Input Common<br>Jumper PI Setpoint or Feedback Test<br>6 24Vout Control Voltage Output (0.1A max.)<br>ON OFF RS485<br>7 GND I/O Ground CURRENT VOLTAGE AO1<br>CURRENT VOLTAGE AI2<br>8 DIN1 START/STOP (Contact closed = start) CURRENT VOLTAGE AI1<br>9 DIN2 External Fault (Closed = fault)<br>10 DIN3 Run Interlock Permissive IP Interlock<br>(Closed = OK)<br>11 COM DIN1–DIN6 Common<br>12 24Vout Control Voltage Output (0.1A max.)<br>13 GND I/O Ground<br>14 DIN4 Speed Select 0–100% (Preset speed)<br>15 DIN5 Fire Mode (Contact closed = fire mode)<br>16 DIN6 Force Bypass (Contact closed = bypass)<br>17 CMB DIN1–DIN6 Common Terminal Block Layout<br>18 AO–1+ Output Frequency (0–20 mA)<br>19 AO–1– Analog Output Common (Ground)<br>30 24 Vdcin Auxiliary Input Voltage 21 22 23 24 25 26 32 33<br>Analog<br>RO1 RO1 RO1 RO2 RO2 RO2 RO3 RO3<br>A DATA- RS-485 DATA- Programmable BACnet,<br>Modbus, FLN, N2 NC COM NO NC COM NO COM NO<br>B DATA+ RS-485 DATA+<br>21 Relay Board 1 Slot B 12 13 14 15 16 17 18 19 30 A B<br>Default Signal<br>22 RO1 Bypass Run 24 Vdcout GND DI4 DI5 DI6 DI1–6COM AO1+ AO1– 24 Vdcin RS-485Data– RS-485Data+<br>23<br>24 Vdc/8A 1 2 3 4 5 6 7 8 9 10 11<br>24 250 Vac/8A<br>25 RO2 Drive Run 125 Vdc/0.4A Vdc+10 AI1+ AI1– AI2+ AI2– 24 Vdcout GND DI1 DI2 DI3 DI1–6COM<br>26<br>32<br>33 RO3 Fault Factory Jumper<br>External Interlock<br>Slot E __________________<br>Slot D __________________<br>**----- End of picture text -----**<br>
## _**Standards**_
## _**Reliability**_
## _**Includes**_
- Six digital input
- Pretested components
- Digital inputs D1–D6, relay out, analog in/out are freely programmed
- Conformal coated (varnished) boards
- Two analog input
- One analog output
- The user can assign a single input to multiple functions
- 40°C rated
- Three relay output
- 110% overload for one minute
- RS-485
- Ethernet (BACnet and Modbus)
- Eaton Electrical Services & Systems national network of AF drive specialists
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-139**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2**
## **H-Max Series Frames FS4–FS7**
|||||H1||W1||W2|
|---|---|---|---|---|---|---|---|---|
|H3|||||||H2||
||||||||||
|||D||||||W3|
|**Voltage**||**hp**|**kW**|**Amps**|**D**|**H1**<br>**Hole**<br>**Center-to-Center**<br>**H2**|||
|**FS4**|||||||||
|230 Vac||0.75–4<br>0.55–3.0<br>3.7–12.5<br>1.5–7.5<br>1.1–5.5<br>3.4–12|||7.77<br>(197.3)|12.89<br>(327.5)<br>12.32<br>(313.0)||11.22<br>(285.0)<br>5.04<br>(128.0)<br>3.94<br>(100.0)<br>3.94<br>(100.0)<br>13.2<br>(6)|
|480 Vac|||||||||
|**FS5**||5–10<br>4–7.5<br>18–31<br>10–20<br>7.5–15<br>16–31|||||||
|230 Vac|||||8.73<br>(221.6)|16.50<br>(419.0)<br>15.98<br>(406.0)||15.04<br>(382.0)<br>5.67<br>(144.0)<br>4.53<br>(115.0)<br>3.94<br>(100.0)<br>22.0<br>(10)|
|480 Vac|||||||||
|**FS6**||15–20<br>11–15<br>48–62<br>25–40<br>18.5–30<br>38–61|||||||
|230 Vac|||||9.29<br>(236.0)|21.93<br>(557.0)<br>21.28<br>(540.5)||20.24<br>(514.0)<br>7.68<br>(195.0)<br>5.83<br>(148.0)<br>5.83<br>(148.0)<br>44.1<br>(20)|
|480 Vac|||||||||
|**FS7**||25–30<br>18.5–30<br>75–105<br>50–75<br>37–55<br>72–105|||||||
|230 Vac|||||10.49<br>(266.5)|25.98<br>(660.0)<br>25.39<br>(645.0)||24.29<br>(617.0)<br>9.06<br>(230.0)<br>7.48<br>(190.0)<br>7.48<br>(190.0)<br>82.6<br>(37.5)|
|480 Vac|||||||||
## **H-Max Series Frames FS8 and FS9**
|||||W1|W1|W1|||||
|---|---|---|---|---|---|---|---|---|---|---|
|H3||||||||||H1|
|||D|||||||||
||||||||||||
|**Voltage**||**hp**|**kW**<br>**Amps**||||**D**||||
|**FS8**|||||||||||
|230 Vac||50–75<br>37–55<br>140–205<br>100–150<br>75–110|||||13.76<br>(349.6)|||38.02<br>(965.7)<br>37.26<br>(946.4)<br>37.26<br>(946.4)<br>11.42<br>(290.1)<br>9.29<br>(236.0)<br>1.42<br>(36.0)<br>154.3<br>(70)|
|480 Vac|||||||||||
|**FS9**||100–120<br>75–90<br>261–310<br>200–250<br>132–160|||||||||
|230 Vac|||||||14.63<br>(371.6)|||33.09<br>(890.4)<br>31.89<br>(810.0)<br>31.89<br>(810.0)<br>18.90<br>(480.0)<br>15.75<br>(400.0)<br>1.57<br>(40.0)<br>238.1<br>(108)|
|480 Vac|||||||||||
**Note:** For flange dimension, please reference User Manual.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-140**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **H-Max IntelliPass and IntelliDisconnect Drives**
## **Contents**
**==> picture [243 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Page|
|H-Max Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|V6-T2-132|
|H-Max IntelliPass and IntelliDisconnect Drives|
|Catalog Number Selection . . . . . . . . . . . . . . . .|V6-T2-142|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|V6-T2-143|
|Technical Data and Specifications . . . . . . . . . .|V6-T2-151|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .|V6-T2-152|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|V6-T2-154|
**----- End of picture text -----**<br>
**2**
## **H-Max IntelliPass and IntelliDisconnect Drives**
## **Product Description**
The IntelliPass electronic bypass is a two or optional three contactor design using a 24 Vdc _**XT**_ Series contactor with an optional manual override switch that allows the unit to run in bypass without the H-Max Series drive.
The IntelliPass software parameters utilize engineering units common to the HVAC industry. Onboard startup wizard guarantees flawless commissioning with plugand-play screen entry. Available in NEMA/UL Type 1, Type 12 and Type 3R with optional pre-engineered operator devices to meet all customized specification requirements.
## **Features and Benefits**
Industry-leading energy saving solution—uses the Eaton H-Max drive with Active Energy Control algorithm.
Built to be as tough as the application—Eaton’s robust design boasts an industrial grade enclosure and industry proven components.
- Industrial Power Supply
- _**XT**_ Contactors
- 22 mm Pilot Devices
## _**Designed with Our Customers in Mind**_
- Removable top and bottom entry panels
- Door-mounted graphic display and keypad
- Easily accessible connection terminals with removable I/O terminal connections
## _**Engineered Product Solution**_
- The Eaton H-Max IntelliPass and IntelliDisconnect products are available with a variety of factory tested and certified options meeting or exceeding UL508C requirements
## **Standards and Certifications** _**Product**_
- IEC 61800-5-1
- UL508C
- cUL
- OSHPD Seismic Certified
The IntelliPass construction features allow for easy installation, reliable operation and serviceability with additional onboard wire space, and removable conduit plates with knockouts.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-141**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Catalog Number Selection**
**2**
## **H-Max Series IntelliPass and IntelliDisconnect Drives**
**==> picture [501 x 420] intentionally omitted <==**
**----- Start of picture text -----**<br>
HMX 011 3 4 N A _ _ Build options alphabetically and numerically. _ _ _ _ _ _ _ _<br>Product Software Series Extended I/O Options in Slot D and E<br>HMX = HVAC drive (VT) A–Z B1 = 6 x DI /DO, Each digital input can be individually<br>(low overload) programmed as digital output<br>B2 = 1RO (NC/NO), 1RO (NO), 1 Thermistor<br>B4 = 1 x AI, 2 x AO (isolated)<br>NEC Ampere Ratings Braking/Application B5 = 3 x RO<br>208 Volts 480 Volts N = No brake chopper B9 = 1RO (NO), 5 DI 42–240 Vac input<br>4D6 = 4.6A—1 hp 2D1 = 2.1A—1 hp (low overload) BF = Expander IO, 1 AO, 1 DO, 1 RO<br>7D5 = 7.5A—2 hp 3D4 = 3.4A—2 hp<br>011 = 11A—3 hp 5D6 = 5.6A—3 hp<br>017 = 17A—5 hp 7D6 = 7.6A—5 hp Voltage Optional Communications in Slot D and E<br>025 = 25A—7.5 hp 011 = 11A—7.5 hp 1 = 208V C4 = LonWorks<br>031 = 31A—10 hp 014 = 14A—10 hp 2 = 230V<br>047 = 47A—15 hp 021 = 21A—15 hp 4 = 480V<br>060 = 60A—20 hp 027 = 27A—20 hp EMC Upgrade Option Keypad Options<br>075 = 75A—25 hp 034 = 34A—25 hp EMC C2 Standard None available<br>088 = 88A—30 hp 040 = 40A—30 hp Enclosure Style<br>230 Volts 052 = 52A—40 hp 3 = IntelliPass NEMA Type 1<br>6D89D60160224D2 = = = = = 4.2A—1 hp 6.8A—2 hp 9.6A—3 hp 16A—5 hp 22A—7.5 hp 065077096 = = = 65A—50 hp77A—60 hp96A—75 hp 45ABC ===== IntelliDisconnect NEMA Type 1IntelliDisconnect NEMA Type 12IntelliDisconnect NEMA Type 3RIntelliPass NEMA Type 12IntelliPass NEMA Type 3R L3P3PESA = = = = Fused drive isolation Output contactor Pilot lights (Power ON, RUN, Fault)Space heater w/transformer (Type 3R only) IntelliDisconnect Options<br>028 = 28A—10 hp<br>042 = 42A—15 hp<br>054 = 54A—20 hp<br>068 = 68A—25 hp IntelliPass Bypass Options<br>080 = 80A—30 hp L4 = Pilot lights (Power ON, RUN, Fault, Bypass)<br>P3 = Fused drive isolation (can not be used with P6 or MI)<br>P6 = Third contactor drive isolation<br>(cannot be used with P3, IS or MI)<br>M1 = Manual bypass, includes isolation contactor and pilot<br>lights (not available with P3, L4, P6 or IS)<br>SA = Space heater w/transformer (Type 3R only)<br>K9 = Auxiliary contacts<br>IS = Isolation switch (cannot be used with P6 or MI)<br>Standard Onboard Communications<br>RS-485 Communications<br>BACnet MS/TP = Master slave/token protocol (Universal BACnet) RS-485<br>Modbus RTU RS-485, ASCII or RTU, remote terminal unit 32 nodes<br>N2 = Johnson Controls Metasys N2 network<br>Onboard Ethernet-Based Communications<br>(port left side of keypad)<br>BACnet /IP Ethernet industrial protocol<br>Modbus /TCP Transmission control protocol (Ethernet-based)<br>**----- End of picture text -----**<br>
## _**Notes**_
IntelliPass—two contactor electronic bypass standard. All boards are varnished. Corrosion resistant. Battery included in all drives for real-time clock. Three year lifetime. Keypad kit includes HOA bypass. EMI/RFI filters included. DC link choke included.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-142**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Product Selection**
## _**H-Max Series IntelliPass NEMA Type 1—Two Contactor Bypass Standard**_
**2**
**HMX_**
|**208 Vac**||||
|---|---|---|---|
|**FS**<br>**Frame Size**<br>4<br>5<br>6<br>7|**Horsepower**<br>1<br>2<br>3<br>5<br>7.5<br>10<br>15<br>20<br>25|**Drive Rated**<br>**NEC Amps**<br>4.6<br>7.5<br>10.6<br>16.7<br>24.2<br>30.8<br>46.2<br>59.4<br>74.9|**Catalog Number**<br>**HMX4D631NA**<br>**HMX7D531NA**<br>**HMX01131NA**<br>**HMX01731NA**<br>**HMX02531NA**<br>**HMX03131NA**<br>**HMX04731NA**<br>**HMX06031NA**<br>**HMX07531NA**|
||30|88|**HMX08831NA**|
|**230 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**|**Horsepower**|**NEC Amps**|**Catalog Number**|
|4|1|4.2|**HMX4D232NA**|
||2|6.8|**HMX6D832NA**|
||3|9.6|**HMX9D632NA**|
|5|5|15.2|**HMX01632NA**|
||7.5|22|**HMX02232NA**|
||10|28|**HMX02832NA**|
|6|15|42|**HMX04232NA**|
||20|54|**HMX05432NA**|
|7|25|68|**HMX06832NA**|
||30|80|**HMX08032NA**|
## **480 Vac**
|**FS**||**Drive Rated**||
|---|---|---|---|
|**Frame Size**|**Horsepower**|**NEC Amps**|**Catalog Number**|
|4|1|2.1|**HMX2D134NA**|
||2|3.4|**HMX3D434NA**|
||3|5.6|**HMX5D634NA**|
||5|7.6|**HMX7D634NA**|
||7.5|11|**HMX01134NA**|
|5|10|14|**HMX01434NA**|
||15|21|**HMX02134NA**|
||20|27|**HMX02734NA**|
|6|25|34|**HMX03434NA**|
||30|40|**HMX04034NA**|
||40|52|**HMX05234NA**|
|7|50|65|**HMX06534NA**|
||60|77|**HMX07734NA**|
||75|96|**HMX09634NA**|
## _**Notes**_
For Wiring Diagrams, see **Page V6-T2-153** . For NEMA 12 or 3R enclosures, see Catalog Number Selection on **Page V6-T2-142** . Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-143**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## _**H-Max Series IntelliPass NEMA Type 12—Two Contactor Bypass Standard**_
**2**
## **HMX_**
|**208 Vac**<br>**FS**||**Drive Rated**||
|---|---|---|---|
|**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>4.6|**Catalog Number**<br>**HMX4D641NA**|
||2<br>3|7.5<br>10.6|**HMX7D541NA**<br>**HMX01141NA**|
|5|5|16.7|**HMX01741NA**|
||7.5|24.2|**HMX02541NA**|
||10|30.8|**HMX03141NA**|
|6|15|46.2|**HMX04741NA**|
||20|59.4|**HMX06041NA**|
|7|25<br>30|74.9<br>88|**HMX07541NA**<br>**HMX08841NA**|
## **230 Vac**
|**230 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>4.2|**Catalog Number**<br>**HMX4D242NA**|
||2|6.8|**HMX6D842NA**|
||3|9.6|**HMX9D642NA**|
|5|5|15.2|**HMX01642NA**|
||7.5|22|**HMX02242NA**|
||10|28|**HMX02842NA**|
|6|15|42|**HMX04242NA**|
||20|54|**HMX05442NA**|
|7|25<br>30|68<br>80|**HMX06842NA**<br>**HMX08042NA**|
## **480 Vac**
|**480 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>2.1|**Catalog Number**<br>**HMX2D144NA**|
||2|3.4|**HMX3D444NA**|
||3|5.6|**HMX5D644NA**|
||5|7.6|**HMX7D644NA**|
||7.5|11|**HMX01144NA**|
|5|10|14|**HMX01444NA**|
||15|21|**HMX02144NA**|
||20|27|**HMX02744NA**|
|6|25<br>30|34<br>40|**HMX03444NA**<br>**HMX04044NA**|
||40|52|**HMX05244NA**|
|7|50|65|**HMX06544NA**|
||60|77|**HMX07744NA**|
||75|96|**HMX09644NA**|
## _**Notes**_
For Wiring Diagrams, see **Page V6-T2-153** . For NEMA 12 or 3R enclosures, see Catalog Number Selection on **Page V6-T2-142** . Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-144**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## _**H-Max Series IntelliPass NEMA Type 3R—Two Contactor Bypass Standard**_
|**HMX_**|**208 Vac**||||
|---|---|---|---|---|
||**FS**||**Drive Rated**||
||**Frame Size**|**Horsepower**|**NEC Amps**|**Catalog Number**|
||4|1|4.6|**HMX4D651NA**|
|||2|7.5|**HMX7D551NA**|
|||3|10.6|**HMX01151NA**|
||5|5|16.7|**HMX01751NA**|
|||7.5|24.2|**HMX02551NA**|
|||10|30.8|**HMX03151NA**|
||6|15|46.2|**HMX04751NA**|
|||20|59.4|**HMX06051NA**|
||7|25|74.9|**HMX07551NA**|
|||30|88|**HMX08851NA**|
||**230 Vac**||||
||**FS**||**Drive Rated**||
||**Frame Size**|**Horsepower**|**NEC Amps**|**Catalog Number**|
||4|1|4.2|**HMX4D252NA**|
|||2|6.8|**HMX6D852NA**|
|||3|9.6|**HMX9D652NA**|
||5|5|15.2|**HMX01652NA**|
|||7.5|22|**HMX02252NA**|
|||10|28|**HMX02852NA**|
||6|15|42|**HMX04252NA**|
|||20|54|**HMX05452NA**|
||7|25|68|**HMX06852NA**|
|||30|80|**HMX08052NA**|
**2**
## **480 Vac**
|**480 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**|**Horsepower**|**NEC Amps**|**Catalog Number**|
|4|1|2.1|**HMX2D154NA**|
||2|3.4|**HMX3D454NA**|
||3|5.6|**HMX5D654NA**|
||5|7.6|**HMX7D654NA**|
||7.5|11|**HMX01154NA**|
|5|10|14|**HMX01454NA**|
||15|21|**HMX02154NA**|
||20|27|**HMX02754NA**|
|6|25|34|**HMX03454NA**|
||30|40|**HMX04054NA**|
||40|52|**HMX05254NA**|
|7|50|65|**HMX06554NA**|
||60|77|**HMX07754NA**|
||75|96|**HMX09654NA**|
## _**Notes**_
For Wiring Diagrams, see **Page V6-T2-153** . For NEMA 12 or 3R enclosures, see Catalog Number Selection on **Page V6-T2-142** . Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-145**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## _**H-Max Series IntelliDisconnect NEMA Type 1—Main Disconnect Standard**_
**2**
## **HMX_**
## **208 Vac**
|**208 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>4.6|**Catalog Number**<br>**HMX4D6A1NA**|
||2<br>3|7.5<br>11|**HMX7D5A1NA**<br>**HMX011A1NA**|
|5|5|17|**HMX017A1NA**|
||7.5|25|**HMX025A1NA**|
||10|31|**HMX031A1NA**|
|6|15|47|**HMX047A1NA**|
||20|60|**HMX060A1NA**|
|7|25<br>30|75<br>88|**HMX075A1NA**<br>**HMX088A1NA**|
## **230 Vac**
|**230 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>4.2|**Catalog Number**<br>**HMX4D2A2NA**|
||2|6.8|**HMX6D8A2NA**|
||3|9.6|**HMX9D6A2NA**|
|5|5|15.2|**HMX016A2NA**|
||7.5|22|**HMX022A2NA**|
||10|28|**HMX028A2NA**|
|6|15|42|**HMX042A2NA**|
||20|54|**HMX054A2NA**|
|7|25<br>30|68<br>80|**HMX068A2NA**<br>**HMX080A2NA**|
## **480 Vac**
|**480 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>2.1|**Catalog Number**<br>**HMX2D1A4NA**|
||2|3.4|**HMX3D4A4NA**|
||3|5.6|**HMX5D6A4NA**|
||5|7.6|**HMX7D6A4NA**|
||7.5|11|**HMX011A4NA**|
|5|10|14|**HMX014A4NA**|
||15|21|**HMX021A4NA**|
||20|27|**HMX027A4NA**|
|6|25<br>30|34<br>40|**HMX034A4NA**<br>**HMX040A4NA**|
||40|52|**HMX052A4NA**|
|7|50|65|**HMX065A4NA**|
||60|77|**HMX077A4NA**|
||75|96|**HMX096A4NA**|
## _**Notes**_
For Wiring Diagrams, see **Page V6-T2-153** . For NEMA 12 or 3R enclosures, see Catalog Number Selection on **Page V6-T2-142** . Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-146**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## _**H-Max Series IntelliDisconnect NEMA Type 12—Main Disconnect Standard**_
## **208 Vac HMX_**
|**208 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**|**Horsepower**|**NEC Amps**|**Catalog Number**|
|4|1|4.6|**HMX4D6B1NA**|
||2|7.5|**HMX7D5B1NA**|
||3|11|**HMX011B1NA**|
|5|5|17|**HMX017B1NA**|
||7.5|25|**HMX025B1NA**|
||10|31|**HMX031B1NA**|
|6|15|47|**HMX047B1NA**|
||20|60|**HMX060B1NA**|
|7|25|75|**HMX075B1NA**|
||30|88|**HMX088B1NA**|
**2**
## **230 Vac**
|**230 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**|**Horsepower**|**NEC Amps**|**Catalog Number**|
|4|1|4.2|**HMX4D2B2NA**|
||2|6.8|**HMX6D8B2NA**|
||3|9.6|**HMX9D6B2NA**|
|5|5|15.2|**HMX016B2NA**|
||7.5|22|**HMX022B2NA**|
||10|28|**HMX028B2NA**|
|6|15|42|**HMX042B2NA**|
||20|54|**HMX054B2NA**|
|7|25|68|**HMX068B2NA**|
||30|80|**HMX080B2NA**|
## **480 Vac**
|**480 Vac**||||
|---|---|---|---|
|**FS**||**Drive Rated**||
|**Frame Size**|**Horsepower**|**NEC Amps**|**Catalog Number**|
|4|1|2.1|**HMX2D1B4NA**|
||2|3.4|**HMX3D4B4NA**|
||3|5.6|**HMX5D6B4NA**|
||5|7.6|**HMX7D6B4NA**|
||7.5|11|**HMX011B4NA**|
|5|10|14|**HMX014B4NA**|
||15|21|**HMX021B4NA**|
||20|27|**HMX027B4NA**|
|6|25|34|**HMX034B4NA**|
||30|40|**HMX040B4NA**|
||40|52|**HMX052B4NA**|
|7|50|65|**HMX065B4NA**|
||60|77|**HMX077B4NA**|
||75|96|**HMX096B4NA**|
## _**Notes**_
For Wiring Diagrams, see **Page V6-T2-153** . For NEMA 12 or 3R enclosures, see Catalog Number Selection on **Page V6-T2-142** . Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-147**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## _**H-Max Series IntelliDisconnect NEMA Type 3R—Main Disconnect Standard**_
**2**
|**HMX_**|**208 Vac**<br>**FS**||**Drive Rated**||
|---|---|---|---|---|
||**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>4.6|**Catalog Number**<br>**HMX4D6C1NA**|
|||2<br>3|7.5<br>11|**HMX7D5C1NA**<br>**HMX011C1NA**|
||5|5|17|**HMX017C1NA**|
|||7.5|25|**HMX025C1NA**|
|||10|31|**HMX031C1NA**|
||6|15|47|**HMX047C1NA**|
|||20|60|**HMX060C1NA**|
||7|25<br>30|75<br>88|**HMX075C1NA**<br>**HMX088C1NA**|
|**230 Vac**<br>**FS**||**Drive Rated**||
|---|---|---|---|
|**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>4.2|**Catalog Number**<br>**HMX4D2C2NA**|
||2|6.8|**HMX6D8C2NA**|
||3|9.6|**HMX9D6C2NA**|
|5|5|15.2|**HMX016C2NA**|
||7.5|22|**HMX022C2NA**|
||10|28|**HMX028C2NA**|
|6|15|42|**HMX042C2NA**|
||20|54|**HMX054C2NA**|
|7|25<br>30|68<br>80|**HMX068C2NA**<br>**HMX080C2NA**|
|**480 Vac**<br>**FS**||**Drive Rated**||
|**Frame Size**<br>4|**Horsepower**<br>1|**NEC Amps**<br>2.1|**Catalog Number**<br>**HMX2D1C4NA**|
||2|3.4|**HMX3D4C4NA**|
||3|5.6|**HMX5D6C4NA**|
||5|7.6|**HMX7D6C4NA**|
||7.5|11|**HMX011C4NA**|
|5|10|14|**HMX014C4NA**|
||15|21|**HMX021C4NA**|
||20|27|**HMX027C4NA**|
|6|25<br>30|34<br>40|**HMX034C4NA**<br>**HMX040C4NA**|
||40|52|**HMX052C4NA**|
|7|50|65|**HMX065C4NA**|
||60|77|**HMX077C4NA**|
||75|96|**HMX096C4NA**|
## _**Notes**_
For Wiring Diagrams, see **Page V6-T2-153** . For NEMA 12 or 3R enclosures, see Catalog Number Selection on **Page V6-T2-142** . Call Technical Support for NEMA 3R specifics. Enclosure size and weight differ from NEMA 1 and 12 products.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-148**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## _**Onboard Network Communications**_
## **Johnson Controls Metasys N2**
H-Max Series provides communication between the drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. N2 can be selected and programmed by the drive keypad.
## **BACnet**
H-Max Series provides communication to BACnet networks. Data transfer is master-slave/token passing (MS/TP) RS-485.
## **BACnet IP**
100Base-T interface.
## **Modbus TCP**
## **Modbus RTU**
H-Max Series provides . communication to Modbus RTU RS-485 as a slave on a Modbus network. Other communication parameters include an address range from 1 to 247; a parity of None, Odd or Even; and the stop bit is 1.
**2**
Ethernet based protocol.
## _**H-Max Series Option Board Kits Available for Slots D and E**_
The H-Max Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your
application needs. The drive’s control unit is designed to accept a total of two option boards.
The H-Max Series factoryinstalled standard board configuration includes an I/O board and a relay output board.
## **Option Boards Mounted in Slots D and E**
|**Option Boards Mounted in Slots D and E**||
|---|---|
||**Option Kit**|
|**Option Kit Description**|**Catalog Number**|
|6 x DI /DO, each digital input can be individually programmed as digital output|**XMX-IO-B1-A**|
|1RO Form C (NO/NC), 1RO Form A (NO), 1 thermistor|**XMX-IO-B2-A**|
|1 x AI, 2 x AO (isolated)|**XMX-IO-B4-A**|
|3 x RO Form A (NO)|**XMX-IO-B5-A**|
|1RO Form A (NO), 5DI 42–240 Vac input|**XMX-IO-B9-A**|
|LonWorks|**XMX-COM-C4-A**|
|1 x AO, 1 x DO, 1 x RO|**XMX-IO-BF-A**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-149**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Extended I/O Options in Slot D and E**
||**Etndd I/O Otin in Slt D and E**|
|---|---|
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>|**xee pos o**<br>**Description**<br>**Suffix**<br>**Number**|
||6 x DI /DO, Each digital input can be individually<br>programmed as digital output<br>**B1**|
||1RO (NC/NO), 1RO (NO), 1 Thermistor<br>**B2**|
||1 x AI, 2 x AO (isolated)<br>**B4**|
||3 x RO<br>**B5**|
||1RO (NO), 5 DI 42–240 Vac input<br>**B9**|
||Expander IO, 1 AO, 1 DO, 1 RO<br>**BF**|
## **Optional Communications in Slot D and E**
|**Description**|**Suffix**<br>**Number**|
|---|---|
|LonWorks|**C4**|
## **IntelliDisconnect Options**
|**IntelliDisconnect Options**||
|---|---|
|**Description**|**Suffix**<br>**Number**|
|Pilot lights (Power ON, RUN, Fault)<br>Fused drive isolation (cannot be used with PE)|**L3**<br>**P3**|
|Output contactor (cannot be used with P3)|**PE**|
|Space heater w/transformer (Type 3R only)|**SA**|
## **IntelliPass Bypass Options**
|**IntelliPass Bypass Options**||
|---|---|
||**Suffix**|
|**Description**|**Number**|
|Pilot lights (Power ON, RUN, Fault)|**L4**|
|Fused drive isolation (can not be used with P6)|**P3**|
|Third contactor drive isolation (cannot be used with P3 or IS)<br>Manual bypass switch located on front door|**P6**<br>**M1**|
|Space heater w/transformer (Type 3R only)|**SA**|
|Auxiliary contacts|**K9**|
|Isolation switch|**IS**|
## **Standard Onboard Communications**
|**Standard Onboard Communications**||
|---|---|
||**Suffix**|
|**Description**|**Number**|
|**RS-485 Communications**||
|BACnet MS/TP = Master slave/token protocol (Universal BACnet) RS-485<br>Modbus RTU RS-485, ASCII or RTU, remote terminal unit 32 nodes|**BACnet**<br>**Modbus**|
|Johnson Controls Metasys N2 network|**N2**|
|**Onboard Ethernet-Based Communications**||
|**(port left side of keypad)**<br>BACnet/IP Ethernet industrial protocol|**BACnet**|
|Modbus/TCP Transmission control protocol (Ethernet-based)|**Modbus**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-150**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Technical Data and Specifications**
## **Primary Design Features**
|**Description**|**IntelliPass**|**IntelliDisconnect**|
|---|---|---|
|CB MMP|Standard|Standard|
|2 contactor bypass|Standard|N/A|
|Electrical interlock|Standard|N/A|
|Third contactor (isolation)|Optional|N/A|
|**Description**|**IntelliPass**|**IntelliDisconnect**|
|---|---|---|
|Isolation switch<br>Top entry (power)|Optional<br>Standard|N/A<br>Standard|
|Bottom entry (power)|Standard|Standard|
|Output contactor|Standard|Optional|
**2**
## **H-Max Series Drives**
|**Description**|**Specification**|
|---|---|
|**Input Ratings**||
|Input voltage (Vin)|208, 230, 480 Vac, –10%/+10%|
|Input frequency (fin)|50/60 Hz (variation up to 47–66 Hz)|
|Connection to power|Once per minute or less (typical operation)|
|Short-circuit withstand|65 kAIC combination|
|rating||
|**Output Ratings**||
|Output voltage|0 to Vin/Uinline voltage in|
|Continuous output current|Ambient temperature max. 104°F (40°C)|
|ILoverload|1.1 x IL(1 min./10 min.)|
|Overload current|110% (1 min./10 min.)|
|Initial output current|150% for two seconds|
|Output frequency|0 to 320 Hz|
|Frequency resolution|0.01 Hz|
|**Control Characteristics**||
|Control method|Frequency control (V/f) open loop sensorless vector control|
|Switching frequency|1–310 amps; adjustable with parameter 2.6.9|
||FS4–FS7: default 6 kHz|
|Frequency reference|Analog input: Resolution 0.1% (10-bit), accuracy ±1%|
||Panel reference: Resolution 0.01 Hz|
|Field weakening point|8 to 320 Hz|
|Acceleration time|0.1 to 3000 seconds|
|Deceleration time|0.1 to 3000 seconds|
|Braking torque|DC brake: 30% x Tn|
|**Ambient Conditions**||
|Ambient operating|FS4–FS7: 14°F (–10°C), no frost to 104°F (40°C)|
|temperature|(Drive can operate at 122°F (50°C)|
|Storage temperature|–40° to 158°F (–40° to 70°C)|
|Relative humidity|0 to 95% RH, noncondensing, non-corrosive, no dripping water|
|Air quality|Chemical vapors: IEC 60721-3-3, unit in operation, Class 3C2;|
||Mechanical particles: IEC 60721-3-3, unit in operation, Class 3S2|
|Altitude|100% load capacity (no derating) up to 3280 ft (1000m);|
||1% derating for each 328 ft (100m) above 3280 ft (1000m);|
||max. 9842 ft (3000m); 380–480V|
|Vibration|FS4–FS7: IEC 60068-2-6, 10–150 Hz|
||Displacement amplitude = 1 mm peak-to-peak from 10–15.8 Hz|
||Max. acceleration amplitude = 1G peak from 15.8–150 Hz|
|Shock|FS4–FS7: IEC 60068-2-27, 15G peak acceleration at 11 ms|
||duration, 1/2-sine. ISTA 1A Certified|
|Enclosure class|NEMA Type 1/IP21 or NEMA Type 12/IP54|
||(keypad required for IP54/Type 12)|
|**Description**|**Specification**|
|---|---|
|**Standards**||
|EMC|Immunity: Fulfills all EMC immunity requirements;<br>Emissions: EN 61800-3, LEVEL H (EMC C2)|
|Emissions|EMC level dependent—<br>+EMC 2: EN61800-3 (2004) Category C2|
||Delivered with Class C2 EMC filtering as default.|
|**Control Connections**||
|Analog input voltage|0 to 10V, R = 200 kohms differential<br>Resolution 0.1%; Accuracy ±1%<br>DIP switch selection (voltage/current)|
|Analog input current|0(4) to 20 mA; Ri–250 ohms differential|
|Digital inputs (6)|Positive or negative logic; 18 to 30 Vdc|
|Auxiliary voltage|+24V ±10%, max. 250 mA|
|Output reference voltage<br>Analog output|+10V +3%, max. load 10 mA<br>0–10V, 0(4) to 20 mA; RLmax. 500 ohms;|
||Resolution 10 bit; Accuracy ±2%;<br>DIP switch selection (voltage/current)|
|Relay outputs|3 programmable, 2 Form C, 1 Form A relay outputs|
||Switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A|
|Hard wire jumper|Between terminal 6 and 10 factory default|
|DIP switch setting default|RS-485 = off|
||A01 = current|
||A12 = current<br>A11 = voltage|
## **Protections**
|Overcurrent protection|Yes|
|---|---|
|Overvoltage protection|Yes|
|DC bus regulation anti-trip|Yes (accelerates or decelerates the load)|
|Undervoltage protection|Yes|
|Earth fault protection|Yes (in case of earth fault in motor or motor cable,<br>only the frequency converter is protected)|
|Input phase supervision<br>Motor phase supervision|Yes (trips if any of the input phases are missing)<br>Yes (trips if any of the output phases are missing)|
|Overtemperature protection|Yes|
|Motor overload protection|Yes|
|Motor stall protection|Yes|
|Motor underload protection|Yes|
|Short-circuit protection|Yes|
|Surge protection<br>Conformed coated|Yes (varistor input)<br>Yes (prevents corrosion)|
|(varnished) board||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-151**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Wiring Diagrams**
**2**
## **Control Input/Output, PID Application**
**==> picture [503 x 496] intentionally omitted <==**
**----- Start of picture text -----**<br>
RJ-45 BACnet/IP Ethernet Industrial ProtocolModbus/TCP Transmission Control Protocol (Ethernet Based) DB R+ Optional<br>Optional Chopper R- Resistor<br>Circuit L1 Three-Phase Input 5% DC LinkReactor Three-Phase U (T1)<br>Breaker L2 Input Output V (T2) Motor<br>(Single-Phase not available)<br>L3 W (T3)<br>Slot A<br>Terminal Factory Default Signal<br>Resistor 1 +10V Reference Output<br>2 AI–1+ Analog Input Voltage (Range 0–10 Vdc)(can be programmed to current 4–20 mA)<br>3 Vin Analog Output Common (Ground)<br>Analog Input Current (Range 4–20 mA)<br>4 AI–2+ (can be programmed to voltage 0–10 Vdc)<br>PI Setpoint or Feedback<br>Factory 5 AI–2– Analog Input Common<br>Jumper PI Setpoint or Feedback Test<br>6 24Vout Control Voltage Output (0.1A max.)<br>ON OFF RS485<br>7 GND I/O Ground CURRENT VOLTAGE AO1<br>CURRENT VOLTAGE AI2<br>8 DIN1 START/STOP (Contact closed = start) CURRENT VOLTAGE AI1<br>9 DIN2 External Fault (Closed = fault)<br>10 DIN3 Run Interlock Permissive IP Interlock<br>(Closed = OK)<br>11 COM DIN1–DIN6 Common<br>12 24Vout Control Voltage Output (0.1A max.)<br>13 GND I/O Ground<br>14 DIN4 Speed Select 0–100% (Preset speed)<br>15 DIN5 Fire Mode (Contact closed = fire mode)<br>16 DIN6 Force Bypass (Contact closed = bypass)<br>17 CMB DIN1–DIN6 Common Terminal Block Layout<br>18 AO–1+ Output Frequency (0–20 mA)<br>19 AO–1– Analog Output Common (Ground)<br>30 24 Vdcin Auxiliary Input Voltage 21 22 23 24 25 26 32 33<br>Analog<br>RO1 RO1 RO1 RO2 RO2 RO2 RO3 RO3<br>A DATA- RS-485 DATA- Programmable BACnet,<br>Modbus, FLN, N2 NC COM NO NC COM NO COM NO<br>B DATA+ RS-485 DATA+<br>21 Relay Board 1 Slot B 12 13 14 15 16 17 18 19 30 A B<br>Default Signal<br>22 RO1 Bypass Run 24 Vdcout GND DI4 DI5 DI6 DI1–6COM AO1+ AO1– 24 Vdcin RS-485Data– RS-485Data+<br>23<br>24 Vdc/8A 1 2 3 4 5 6 7 8 9 10 11<br>24 250 Vac/8A<br>25 RO2 Drive Run 125 Vdc/0.4A Vdc+10 AI1+ AI1– AI2+ AI2– 24 Vdcout GND DI1 DI2 DI3 DI1–6COM<br>26<br>32<br>33 RO3 Fault Factory Jumper<br>External Interlock<br>Slot E __________________<br>Slot D __________________<br>**----- End of picture text -----**<br>
## _**Standards**_
## _**Reliability**_
## _**Includes**_
- Six digital input
- Pretested components
- Digital inputs D1–D6, relay out, analog in/out are freely programmed
- Conformal coated
- Two analog input
- (varnished) boards
- One analog output
- The user can assign a single input to multiple functions
- 40°C rated
- Three relay output
- 110% overload for one minute
- RS-485
- Ethernet
- Eaton Electrical Services & Systems national network of AF drive specialists
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-152**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **H-Max Series IntelliPass**
## **H-Max Series IntelliDisconnect Power Wiring**
**==> picture [492 x 394] intentionally omitted <==**
**----- Start of picture text -----**<br>
Incoming Power Incoming Power<br>L1 L2 L3 L1 L2 L3<br>Bypass<br>Circuit Circuit<br>Breaker Breaker<br>Optional Fuse<br>Optional Fuse<br>or<br>Drive Input<br>Contactor<br>To Drive Input<br>L1 L2 L3<br>To Drive Output<br>To Drive Input<br>U(T1) V(T2)W(T3)<br>To Drive Output<br>Optional<br>Output<br>Contactor<br>U(T1) V(T2)W(T3)<br>Output Bypass<br>Contactor Contactor<br>V(T2)<br>U(T1) W(T3)<br>Motor<br>Overload<br>Relay<br>V(T2)<br>U(T1) W(T3)<br>Motor<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-153**
Adjustable Frequency Drives
2.6
H-Max Series Drives
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2**
## **H-Max Series IntelliPass and IntelliDisconnect Drives**
**==> picture [366 x 297] intentionally omitted <==**
**----- Start of picture text -----**<br>
W1<br>H3<br>D1<br>H4<br>H1 H2<br>C W2 W3 D2<br>**----- End of picture text -----**<br>
Consult factory or use manual for final dimensions.
|**Frame**<br>**Size**|**Voltage**<br>**Horsepower (IL)**<br>**H1**<br>**H2**<br>**H3**<br>**H4**<br>**C**<br>**W1**<br>**W2**<br>**W3**<br>**D1**<br>**D2**<br>**Weight in**<br>**Lbs (kg)**|
|---|---|
|FS4|208<br>1–3<br>30.00<br>(762.0)<br>29.41<br>(747.1)<br>0.25<br>(6.35)<br>31.00<br>(787.4)<br>3.00<br>(76.2)<br>7.88<br>(200.2)<br>6.25<br>(158.8)<br>0.75<br>(19.1)<br>12.49<br>(317.2)<br>10.36<br>(263.1)<br>45 (20.41)<br>230<br>1–3<br>480<br>1–7.5|
|FS5|208<br>5–10<br>37.00<br>(939.8)<br>36.72<br>(932.7)<br>0.25<br>(6.35)<br>38.31<br>(973.0)<br>3.00<br>(76.2)<br>9.60<br>(243.8)<br>7.97<br>(202.4)<br>0.75<br>(19.1)<br>15.35<br>(390.0)<br>13.22<br>(335.8)<br>57.5 (26.10)<br>230<br>5–10<br>480<br>10–20|
|FS6|208<br>15–20<br>45.45<br>(1154.4)<br>44.81<br>(1138.2)<br>0.25<br>(6.35)<br>46.4<br>(1178.6)<br>4.00<br>(101.6)<br>11.44<br>(290.6)<br>9.75<br>(247.6)<br>0.75<br>(19.1)<br>15.80<br>(401.3)<br>13.67<br>(347.2)<br>98.0 (44.45)<br>230<br>15–20<br>480<br>25–40|
|FS7|208<br>25–30<br>58.51<br>(1486.2)<br>57.87<br>(1470.0)<br>0.25<br>(6.35)<br>59.46<br>(1510.3)<br>5.00<br>(127.0)<br>14.52<br>(368.8)<br>12.83<br>(325.9)<br>0.75<br>(19.1)<br>15.68<br>(398.3)<br>13.72<br>(348.5)<br>165.0 (74.84)<br>230<br>25–30<br>480<br>50–75|
**Note:** C distance is spacing required to mount multiple drives.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-154**
Adjustable Frequency Drives
2.6
H-Max Series Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Box A NEMA Type 3R**
**==> picture [334 x 402] intentionally omitted <==**
**----- Start of picture text -----**<br>
W D<br>H<br>H1 H2 H3<br>W2<br>W3 W1 D2 D1<br>0.44 (11.2)<br>Mounting<br>Holes<br>(4 Places)<br>**----- End of picture text -----**<br>
**2**
||||||||||||||**Approx.**|**Approx.**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**Voltage**|**hp**||||||||||||**Weight**|**Shipping Weight**|
|**AC**|**(IL)**|**H**|**H1**|**H2**|**H3**|**W**|**W1**|**W2**|**W3**|**D**|**D1**|**D2**|**Lbs (kg)**|**Lbs (kg)**|
|**Three-Phase**|||||||||||||||
|208V|1–10|33.00|31.36|29.67|25.35|21.05|16.92|15.30|2.07|17.24|16.26|3.31|170 (77)|215 (98)|
|230V|1–10|(838.2)|(796.5)|(753.6)|(643.9)|(534.7)|(429.8)|(388.6)|(52.6)|(437.9)|(413.0)|(84.1)|||
|480V|1–20||||||||||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-155**
Adjustable Frequency Drives
H-Max Series Drives
## 2.6
Approximate Dimensions in Inches (mm)
## **Enclosure Box B NEMA Type 3R**
|||<br>|<br>|<br>|<br>|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|||W2<br>W1<br>D2<br>W<br>0.44 (11.2)<br>Mounting<br>Holes<br>(4 Places)|D2|||D||||||
|H3<br>H2<br>H1<br>W3||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||D2||||||||
|||||||||||||
|||||||D||||||
|||||||||||||
|||||||||||||
|||||||||||||
|**oltage**<br>**C**<br>**hp**<br>**(IL)**<br>**H**<br>||**H1**<br>**H2**<br>**H3**<br>**W**||||**W1**<br>**W2**||||||
|**hree-Phase**||||||||||||
|08V<br>15<br>46.09<br>(1170.7)<br>4<br>(<br>30V<br>15<br>80V<br>25–40||4.45<br>1129.0)<br>42.77<br>(1086.4)<br>36.35<br>(923.3)<br>26.31<br>(668.3)||||20.92<br>(531.4)<br>19.30<br>(490.2)|||2.69<br>(68.3)<br>17.74<br>(450.6)<br>16.76<br>(425.7)<br>3.31<br>(84.1)<br>235 (107)<br>290 (132)|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-156**
Adjustable Frequency Drives
2.6
H-Max Series Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Box C NEMA Type 3R**
||||0.44 (11.2)<br>Mounting Holes<br>(4 Places)<br>H<br>W2<br>W1<br>W3<br>D2<br>D1<br>W<br>D<br>H||**D**<br>**D1**<br>**D2**<br>**Approx.**<br>**Weight**<br>**Lbs (kg)**<br>D2<br>D1<br>W1<br>W2<br>W<br>D<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|**D**<br>**D1**<br>**D2**<br>**Approx.**<br>**Weight**<br>**Lbs (kg)**<br>D2<br>D1<br>W1<br>W2<br>W<br>D<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|**D**<br>**D1**<br>**D2**<br>**Approx.**<br>**Weight**<br>**Lbs (kg)**<br>D2<br>D1<br>W1<br>W2<br>W<br>D<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|
|---|---|---|---|---|---|---|---|
||||W2<br>W1<br>W||W1<br>W2|D||
|H1|H3<br>H2|||H3<br>2||||
|||||||||
|||||||||
|||||||D1||
|||||||||
|||||||||
|**Voltage**<br>**AC**<br>**hp**<br>**(IL)**<br>**H**|||**H1**<br>**H2**<br>**H3**<br>**W**<br>**W1**|**W2**<br>**W3**||||
|**Three-Phase**||||||||
|208<br>20–30<br>58.09<br>(1475<br>230<br>20–30<br>480<br>50–75|||.5)<br>56.45<br>(1433.8)<br>54.77<br>(1391.2)<br>48.35<br>(1228.1)<br>37.73<br>(958.3)<br>30.92<br>(785.4)|29.30<br>(744.2)<br>3.34<br>(84.8)|17.74<br>(450.6)<br>16.77<br>(426.0)<br>3.31<br>(84.1)<br>1|||
**2**
## _**Note**_
> 1 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-157**
Adjustable Frequency Drives
2.7
SPX9000 Drives
**2** ~~a~~
## **SPX9000 Drives**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|SPX9000 Drives||
|Features and Benefits . . . . . . . . . . . . . . . . . . .|**V6-T2-159**|
|Standards and Certifications . . . . . . . . . . . . . .|**V6-T2-159**|
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V6-T2-160**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-161**|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-166**|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-167**|
|Replacement Parts . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-174**|
|Technical Data and Specifications . . . . . . . . . .|**V6-T2-183**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-184**|
## **Product Description**
The SPX9000 Series Adjustable Frequency Drives from Eaton’s Electrical Sector are specifically designed for high performance applications. Equipped with high processing power, the SPX9000 can use information from an encoder or a resolver in order to provide very precise motor control. Sensorless vector and simple frequency control are also supported. Typical applications requiring high performance are: masterslave drives, positioning applications, winder tension control and synchronization.
The SPX9000 supports fast drive-to-drive communication. It also offers an integrated data logger functionality for analysis of dynamic events without the need of additional hardware. Simultaneous fast monitoring of several drives can be done by using the 9000Xdrive tool and CAN communication. In applications where reliability and quality are essential for high-performance, the SPX9000 is the logical choice.
The Eaton family of drives includes DA1, DC1, H-Max, M-Max, SVX9000 and SPX9000. 9000X Series drive ratings are rated for either high overload (IH) or low overload (IL). IL indicates 110% overload capacity for 1 minute out of 10 minutes. IH indicates 150% overload capacity for 1 minute out of 10 minutes.
The core of the SPX9000 is a fast microprocessor, providing high dynamic performance for applications where good motor handling and reliability are required. It can be used both in open loop applications as well as in applications requiring encoder feedback.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-158**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Features and Benefits**
- Speed error <0.01%, depending on the encoder
- Simplified operating menu ● Additional I/O and allows for typical communication cards programming changes, provide plug and play while programming mode functionality provides control of ● I/O connections with everything simple quick connection
- ● Quick Start Wizard built terminals
- Incremental or absolute encoder support while programming mode functionality
- ● Encoder voltages of 5V provides control of ● I/O connections with (RS-422), 15V or 24V, everything simple quick connection depending on the option ● Quick Start Wizard built terminals card into the programming of ● Control logic can be
- ● Full torque control at all the drive ensures a smooth powered from an external speeds, including zero start-up auxiliary control panel,
- ● Torque accuracy <2%; ● Keypad can display up to internal drive functions and three monitored fieldbus if necessary
- Keypad can display up to three monitored parameters simultaneously
- Torque accuracy <2%; <5% down to zero speed
- Starting torque >200%, ● LOCAL/REMOTE operation ● Brake chopper standard from: 1–30 hp/380–500V depending on motor and from keypad 3/4–15 hp/208–230V
- drive sizing
- Copy/paste function allows ● NEMA Type 1/IP21 transfer of parameter enclosures available Frame settings from one drive to Sizes FR4–FR11, NEMA the next Type 12/IP54 enclosures
- ● Standard NEMA Type 12/ available Frame Sizes FR4– IP54 keypad on all drives FR10 (FR10 and FR11 freestanding drives)
- Integrated datalogger for system analysis
- Fast multiple drive monitoring with PC
- Full capability for master/ slave configurations
- Hand-held auxiliary 240 power supply allows ● Open chassis FR10 and programming/monitoring greater of control module without ● Standard option board applying full power to the configuration includes an drive A9 I/O board and an A2
- ● The SPX can be flexibly relay output board installed adapted to a variety of in slots A and B needs using our preinstalled “Seven in One” precision application programs consisting of:
- High-speed bus (12 Mbit/s) for fast inter-drive communication
- High-speed applications (up to 7200 Hz) possible
- Robust design—proven 500,000 hours MTBF
- Integrated 3% line reactors standard on drives from FR4 through FR9
- Line reactor is included but is separated from chassis
- Basic
- Standard
- EMI/RFI Filters H standard up to 200 hp IH 480V, 100 hp IH 230V
- Local/remote
- Multi-step speed control
**2**
- PID control
- Multi-purpose control
- Pump and fan control with auto change
## **Standards and Certifications**
## _**EMC (at default settings)**_
## _**Product**_
- IEC 61800-2 ● Immunity: Fulfills all EMC ● UL Listed immunity requirements; ● CE
- _**Safety**_ Emissions: EN 61800-3, ● UL 508C LEVEL H
## _**Safety**_
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-159**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Catalog Number Selection**
## **SPX9000 Adjustable Frequency Drives**
**2**
**==> picture [486 x 344] intentionally omitted <==**
**----- Start of picture text -----**<br>
–<br>SPX 010 A 1 4 A 1 B 1 _ _ _ _ _ _<br>Options<br>Product Family Options appear in alphabetical order.<br>SPX = Open drives Extended I/O Card Options<br>A3 = 2 RO, Therm<br>Horsepower Rating A4 = Encoder low volt +5V/15V24V<br>F07 = 3/4 125 = 125 A5 = Encoder high volt +15V/24V<br>A7 = Double Encoder<br>001 = 1 150 = 150<br>F15 = 1-1/2 250 = 250 A8 = 6 DI, 1 DO, 2 AI, 1AO<br>002 = 2 300 = 300 AE = 3 DI (Encoder 10–24V), Out +15V/+24V 2 DO (pulse + direction)<br>003 = 3 350 = 350 B1 = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc<br>004005006007010015 = = = = = = 5 (I57-1/210157-1/2 (IL) L) 400500550600650700 = = = = = = 400500550600650700 B2B4B5B8B9BB = 1 RO (NC-NO), 1 RO (NO), 1 therm = 1 AI (mA isolated), 2 AO (mA isolated), 1 ext +24 Vdc/EXT + 24 Vdc = 3 RO (NO) = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100 = 1 RO (NO), 5 DI 42–240 Vac input = SPI, absolute encoder<br>020 = 20 800 = 800 Communication Cards<br>025 = 25 900 = 900 CA = Johnson Controls N2 C5 = PROFIBUS DP (D9 connector)<br>030 = 30 H10 = 1000 CI = Modbus TCP C6 = CANopen (slave)<br>040 = 40 H12 = 1200 CJ = BACnet C7 = DeviceNet<br>050 = 50 H13 = 1350 CQ = EtherNet/IP C8 = Modbus (D9 type connector)<br>060 = 60 H15 = 1500 C2 = Modbus D1 = Adapter—SPX only<br>075 = 75 H16 = 1600 C3 = PROFIBUS DP D2 = Adapter—SPX only<br>100 = 100 H20 = 2000 C4 = LonWorks D3 = RS-232 with D9 connection<br>AFD Software Series Board Modifications<br>A = Standard software 1 = Standard boards<br>2 = Conformal (varnished) coating [4]<br>Enclosure [3]<br>B rake Chopper Options [2]<br>0 = Chassis<br>1 = NEMA Type 1/IP21 N = No brake chopper circuit<br>2 = NEMA Type 12/IP54 B = Internal brake chopper circuit<br>Voltage Rating Inp ut Options [1]<br>2 = 230V (208–240) 1 = Three-phase, EMC H<br>4 = 480V (380–500) Keyp ad 2 = Three-phase, EMC N<br>5 = 575V (525–690) A = Alphanumeric 4 = Three-phase, EMC L<br>**----- End of picture text -----**<br>
## _**Notes**_
- 1 All 230V drives and 480V drives up to 200 hp (IH) are only available with input option **1** (EMC level H) **.** 480V drives 250 hp (IH) or larger are available with input option **2** (EMC level N). 575V drives 200 hp (IH) or larger are available with input option **2** . 575V drives up to 150 hp (IH) are available with input option **4** (EMC level L). 480V and 690V freestanding drives are available with input option **4** (EMC level L).
- 2 480V drives up to 30 hp (IH) are only available with brake chopper option **B** . 480V drives 40 hp (IH) or larger come standard with brake chopper option **N** . 230V drives up to 15 hp (IH) are only available with brake chopper option **B** . 230V drives 20 hp and larger come standard with brake chopper option **N** . All 575V drives come standard without brake chopper option ( **N** ). **N** = **No** brake chopper.
- 3 480V drives 250–350 hp (IH) and 690V drives 200–300 hp (IH) are available with enclosure style **0** (chassis). 480V and 690V FR10 freestanding drives are available with **1** (NEMA Type 1/IP21) or **2** (NEMA Type 12/IP54). FR11 freestanding drives are only available with enclosure style **1** (NEMA Type 1/IP21).
- 4 Factory promise delivery. Consult sales office for availability.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-160**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Product Selection**
## _**230V Drives**_
**2**
|**SPX9000 Open Drives**|**SPX9000 Open Drives**|**208–240V, NEMA Type 1/IP21 Drives**|**208–240V, NEMA Type 1/IP21 Drives**|**208–240V, NEMA Type 1/IP21 Drives**|**208–240V, NEMA Type 1/IP21 Drives**|||
|---|---|---|---|---|---|---|---|
|||**Frame**||||||
|||**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|||FR4|3/4|3.7|1|4.8|**SPXF07A1-2A1B1**|
||||1|4.8|1-1/2|6.6|**SPX001A1-2A1B1**|
||||1-1/2|6.6|2|7.8|**SPXF15A1-2A1B1**|
||||2|7.8|3|11|**SPX002A1-2A1B1**|
||||3|11|—|12.5|**SPX003A1-2A1B1**|
|||FR5|—|12.5|5|17.5|**SPX004A1-2A1B1**|
||||5|17.5|7-1/2|25|**SPX005A1-2A1B1**|
||||7-1/2|25|10|31|**SPX007A1-2A1B1**|
|||FR6|10|31|15|48|**SPX010A1-2A1B1**|
||||15|48|20|61|**SPX015A1-2A1B1**|
|||FR7|20|61|25|75|**SPX020A1-2A1N1**|
||||25|75|30|88|**SPX025A1-2A1N1**|
||||30|88|40|114|**SPX030A1-2A1N1**|
|||FR8|40|114|50|140|**SPX040A1-2A1N1**|
||||50|140|60|170|**SPX050A1-2A1N1**|
||||60|170|75|205|**SPX060A1-2A1N1**|
|||FR9|75|205|100|261|**SPX075A1-2A1N1**|
||||100|261|—|—|**SPX100A1-2A1N1**|
## **208–240V, NEMA Type 12/IP54 Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR4|3/4|3.7|1|4.8|**SPXF07A2-2A1B1**|
||1|4.8|1-1/2|6.6|**SPX001A2-2A1B1**|
||1-1/2|6.6|2|7.8|**SPXF15A2-2A1B1**|
||2|7.8|3|11|**SPX002A2-2A1B1**|
||3|11|—|12.5|**SPX003A2-2A1B1**|
|FR5|—|12.5|5|17.5|**SPX004A2-2A1B1**|
||5|17.5|7-1/2|25|**SPX005A2-2A1B1**|
||7-1/2|25|10|31|**SPX007A2-2A1B1**|
|FR6|10|31|15|48|**SPX010A2-2A1B1**|
||15|48|20|61|**SPX015A2-2A1B1**|
|FR7|20|61|25|75|**SPX020A2-2A1N1**|
||25|75|30|88|**SPX025A2-2A1N1**|
||30|88|40|114|**SPX030A2-2A1N1**|
|FR8|40|114|50|140|**SPX040A2-2A1N1**|
||50|140|60|170|**SPX050A2-2A1N1**|
||60|170|75|205|**SPX060A2-2A1N1**|
|FR9|75|205|100|261|**SPX075A2-2A1N1**|
||100|261|—|—|**SPX100A2-2A1N1**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-161**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## _**480V Drives**_
**2**
|**SPX9000 Open Drives**|**SPX9000 Open Drives**|**380–500V, NEMA Type 1/IP21 Drives**<br>**Frame**|**380–500V, NEMA Type 1/IP21 Drives**|**380–500V, NEMA Type 1/IP21 Drives**|**380–500V, NEMA Type 1/IP21 Drives**|||
|---|---|---|---|---|---|---|---|
|||**Size**<br>FR4|**hp (IH)**<br>1|**Current (IH)**<br>2.2|**hp (IL)**<br>1-1/2|**Current (IL)**<br>3.3|**Catalog Number**<br>**SPX001A1-4A1B1**|
||||1-1/2|3.3|2|4.3|**SPXF15A1-4A1B1**|
||||2|4.3|3|5.6|**SPX002A1-4A1B1**|
||||3|5.6|5|7.6|**SPX003A1-4A1B1**|
||||5|7.6|—|9|**SPX005A1-4A1B1**|
||||—|9|7-1/2|12|**SPX006A1-4A1B1**|
|||FR5|7-1/2<br>10|12<br>16|10<br>15|16<br>23|**SPX007A1-4A1B1**<br>**SPX010A1-4A1B1**|
||||15|23|20|31|**SPX015A1-4A1B1**|
|||FR6|20|31|25|38|**SPX020A1-4A1B1**|
||||25|38|30|46|**SPX025A1-4A1B1**|
||||30|46|40|61|**SPX030A1-4A1B1**|
|||FR7|40|61|50|72|**SPX040A1-4A1N1**|
||||50|72|60|87|**SPX050A1-4A1N1**|
||||60|87|75|105|**SPX060A1-4A1N1**|
|||FR8|75|105|100|140|**SPX075A1-4A1N1**|
||||100|140|125|170|**SPX100A1-4A1N1**|
||||125|170|150|205|**SPX125A1-4A1N1**|
|||FR9|150<br>200|205<br>245|200<br>250|261<br>300|**SPX150A1-4A1N1**<br>**SPX200A1-4A1N1**|
## **380–500V, NEMA Type 1/IP21 Freestanding Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**<br>FR10|**hp (IH)**<br>250|**Current (IH)**<br>330|**hp (IL)**<br>300|**Current (IL)**<br>385|**Catalog Number**<br>**SPX250A1-4A4N1**|
||300|385|350|460|**SPX300A1-4A4N1**|
||350|460|400|520|**SPX350A1-4A4N1**|
|FR11|400|520|500|590|**SPX400A1-4A4N1**|
||500<br>550|590<br>650|550<br>600|650<br>730|**SPX500A1-4A4N1**<br>**SPX550A1-4A4N1**|
## _**Note**_
Integrated fuses as standard. Limited option selection available; 115V transformer (KB), light kit (L1), HOA (K4), speed potentiometer w/HOA (K2), Disconnect switch (P2). See Freestanding Option selection on **Page V6-T2-173** .
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-162**
Adjustable Frequency Drives
2.7
SPX9000 Drives
|**SPX9000 Open Drives**|**SPX9000 Open Drives**|**380–500V, NEMA Type 12/IP54 Drives**|**380–500V, NEMA Type 12/IP54 Drives**|**380–500V, NEMA Type 12/IP54 Drives**|**380–500V, NEMA Type 12/IP54 Drives**|||
|---|---|---|---|---|---|---|---|
|||**Frame**||||||
|||**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|||FR4|1|2.2|1-1/2|3.3|**SPX001A2-4A1B1**|
||||1-1/2|3.3|2|4.3|**SPXF15A2-4A1B1**|
||||2|4.3|3|5.6|**SPX002A2-4A1B1**|
||||3|5.6|5|7.6|**SPX003A2-4A1B1**|
||||5|7.6|—|9|**SPX005A2-4A1B1**|
||||—|9|7-1/2|12|**SPX006A2-4A1B1**|
|||FR5|7-1/2|12|10|16|**SPX007A2-4A1B1**|
||||10|16|15|23|**SPX010A2-4A1B1**|
||||15|23|20|31|**SPX015A2-4A1B1**|
|||FR6|20|31|25|38|**SPX020A2-4A1B1**|
||||25|38|30|46|**SPX025A2-4A1B1**|
||||30|46|40|61|**SPX030A2-4A1B1**|
|||FR7|40|61|50|72|**SPX040A2-4A1N1**|
||||50|72|60|87|**SPX050A2-4A1N1**|
||||60|87|75|105|**SPX060A2-4A1N1**|
|||FR8|75|105|100|140|**SPX075A2-4A2N1**|
||||100|140|125|170|**SPX100A2-4A1N1**|
||||125|170|150|205|**SPX125A2-4A1N1**|
|||FR9|150|205|200|261|**SPX150A2-4A1N1**|
||||200|245|250|300|**SPX200A2-4A1N1**|
**2**
## **380–500V, NEMA Type 12/IP54 Freestanding Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR10|250|330|300|385|**SPX250A2-4A4N1**|
||300|385|350|460|**SPX300A2-4A4N1**|
||350|460|400|520|**SPX350A2-4A4N1**|
## **380–500V, Open Chassis Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR10|250|330|300|385|**SPX250A0-4A2N1**|
||300|385|—|460|**SPX300A0-4A2N1**|
||350|460|400|520|**SPX350A0-4A2N1**|
|FR11|400|520|500|590|**SPX400A0-4A2N1**|
||500|590|—|650|**SPX500A0-4A2N1**|
||—|650|600|730|**SPX550A0-4A2N1**|
|FR12|600|730|—|820|**SPX600A0-4A2N1**|
||—|820|700|920|**SPX650A0-4A2N1**|
||700|920|800|1030|**SPX700A0-4A2N1**|
|FR13|800|1030|900|1150|**SPX800A0-4A2N1**|
||900|1150|1000|1300|**SPX900A0-4A2N1**|
||1000|1300|1200|1450|**SPXH10A0-4A2N1**|
|FR14|1200|1600|1500|1770|**SPXH12A0-4A2N1**|
||1600|1940|1800|2150|**SPXH16A0-4A2N1**|
## _**Notes**_
Integrated fuses as standard. Limited option selection available; 115V transformer (KB), light kit (L1), HOA (K4), speed potentiometer w/HOA (K2), disconnect switch (P2). See Freestanding Option selection on **Page V6-T2-173** . 1 FR10–FR14 includes 3% line reactor, but it is not integral to chassis.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-163**
Adjustable Frequency Drives
SPX9000 Drives
## 2.7
## _**575V Drives**_
**2**
|**SPX9000 Open Drives**|**SPX9000 Open Drives**|**525–690V, NEMA Type 1/IP21 Drives**<br>**Frame**|**525–690V, NEMA Type 1/IP21 Drives**|**525–690V, NEMA Type 1/IP21 Drives**|**525–690V, NEMA Type 1/IP21 Drives**|||
|---|---|---|---|---|---|---|---|
|||**Size**<br>FR6|**hp (IH)**<br>2|**Current (IH)**<br>3.3|**hp (IL)**<br>3|**Current (IL)**<br>4.5|**Catalog Number**<br>**SPX002A1-5A4N1**|
||||3|4.5|—|5.5|**SPX003A1-5A4N1**|
||||—|5.5|5|7.5|**SPX004A1-5A4N1**|
||||5|7.5|7-1/2|10|**SPX005A1-5A4N1**|
||||7-1/2|10|10|13.5|**SPX007A1-5A4N1**|
||||10|13.5|15|18|**SPX010A1-5A4N1**|
||||15<br>20|18<br>22|20<br>25|22<br>27|**SPX015A1-5A4N1**<br>**SPX020A1-5A4N1**|
||||25|27|30|34|**SPX025A1-5A4N1**|
|||FR7|30|34|40|41|**SPX030A1-5A4N1**|
||||40|41|50|52|**SPX040A1-5A4N1**|
|||FR8|50|52|60|62|**SPX050A1-5A4N1**|
||||60|62|75|80|**SPX060A1-5A4N1**|
||||75|80|100|100|**SPX075A1-5A4N1**|
|||FR9|100|100|125|125|**SPX100A1-5A4N1**|
||||125|125|150|144|**SPX125A1-5A4N1**|
||||150|144|—|170|**SPX150A1-5A4N1**|
||||—|170|200|208|**SPX175A1-5A4N1**|
## **525–690V, NEMA Type 1/IP21 Freestanding Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR10|200|208|250|261|**SPX200A1-5A4N1**|
||250<br>300|261<br>325|300<br>400|325<br>385|**SPX250A1-5A4N1**<br>**SPX300A1-5A4N1**|
|FR11|400|385|450|460|**SPX400A1-5A4N1**|
||450|460|500|502|**SPX450A1-5A4N1**|
||500|502|550|590|**SPX500A1-5A4N1**|
## _**Note**_
Integrated fuses as standard. Limited option selection available; 115V transformer (KB), light kit (L1), HOA (K4), speed potentiometer w/HOA (K2), disconnect switch (P2). See Freestanding Option selection on **Page V6-T2-173** .
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-164**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **SPX9000 Open Drives 525–690V, NEMA Type 12/IP54 Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR6|2|3.3|3|4.5|**SPX002A2-5A4N1**|
||3|4.5|—|5.5|**SPX003A2-5A4N1**|
||—|5.5|5|7.5|**SPX004A2-5A4N1**|
||5|7.5|7-1/2|10|**SPX005A2-5A4N1**|
||7-1/2|10|10|13.5|**SPX007A2-5A4N1**|
||10|13.5|15|18|**SPX010A2-5A4N1**|
||15|18|20|22|**SPX015A2-5A4N1**|
||20|22|25|27|**SPX020A2-5A4N1**|
||25|27|30|34|**SPX025A2-5A4N1**|
|FR7|30|34|40|41|**SPX030A2-5A4N1**|
||40|41|50|52|**SPX040A2-5A4N1**|
|FR8|50|52|60|62|**SPX050A2-5A4N1**|
||60|62|75|80|**SPX060A2-5A4N1**|
||75|80|100|100|**SPX075A2-5A4N1**|
|FR9|100|100|125|125|**SPX100A2-5A4N1**|
||125|125|150|144|**SPX125A2-5A4N1**|
||150|144|—|170|**SPX150A2-5A4N1**|
||—|170|200|208|**SPX175A2-5A4N1**|
**2**
## **525–690V, NEMA Type 12/IP54 Freestanding Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR10|200|208|250|261|**SPX200A2-5A4N1**|
||250|261|300|325|**SPX250A2-5A4N1**|
||300|325|400|385|**SPX300A2-5A4N1**|
## **525–690V, Open Chassis Drives**
|**Frame**||||||
|---|---|---|---|---|---|
|**Size**|**hp (IH)**|**Current (IH)**|**hp (IL)**|**Current (IL)**|**Catalog Number**|
|FR10|200|208|250|261|**SPX200A0-5A2N1**|
||250|261|300|325|**SPX250A0-5A2N1**|
||300|325|400|385|**SPX300A0-5A2N1**|
|FR11|400|385|450|460|**SPX400A0-5A2N1**|
||450|460|500|502|**SPX450A0-5A2N1**|
||500|502|—|590|**SPX500A0-5A2N1**|
|FR12|—|590|600|650|**SPX550A0-5A2N1**|
||600|650|700|750|**SPX600A0-5A2N1**|
||700|750|800|820|**SPX700A0-5A2N1**|
|FR13|800|820|900|920|**SPX800A0-5A2N1**|
||900|920|1000|1030|**SPX900A0-5A2N1**|
||1000|1030|1250|1180|**SPXH10A0-5A2N1**|
|FR14|1350|1300|1500|1500|**SPXH13A0-5A2N1**|
||1500|1500|2000|1900|**SPXH15A0-5A2N1**|
||2000|1900|2300|2250|**SPXH20A0-5A2N1**|
## _**Notes**_
Integrated fuses as standard. Limited option selection available; 115V transformer (KB), light kit (L1), HOA (K4), speed potentiometer w/HOA (K2), disconnect switch (P2). See Freestanding Option selection on **Page V6-T2-173** . 1 FR10–FR14 includes 3% line reactor, but it is not integral to chassis.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-165**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Accessories**
**2**
## _**Demo Drive and Power Supply**_
## **Demo Drive and Power Supply**
|**Description**|**Catalog Number**|
|---|---|
|9000X demo drive|**9000XDEMO**|
## _**NEMA Type 12/IP54 Conversion Kit**_
The NEMA Type 12/IP54 kit option is used to convert a NEMA Type 1/IP21 to a NEMA Type 12/IP54 drive. The NEMA Type 12/IP54
kit consists of a metal drive shroud, fan kit for some frames, adaptor plate and plugs.
## **NEMA Type 12/IP54 Conversion Kit**
|**Frame Size**<br>**Delivery Code**|**Approximate Dimensions in Inches (mm)**<br>**Approximate**<br>**Weight Lb (kg)**<br>**Length**<br>**Width**<br>**Height**<br>**Catalog Number**|
|---|---|
|FR4<br>W<br>FR5<br>FR6|13 (330)<br>7 (178)<br>4 (102)<br>4 (1.8)<br>**OPTN12FR4**|
||16 (406)<br>8 (203)<br>7 (178)<br>5 (2.3)<br>**OPTN12FR5**|
||21 (533)<br>10 (254)<br>5 (127)<br>7 (3.2)<br>**OPTN12FR6**|
## _**Flange Kits**_
## **Flange Kit NEMA Type 12/IP54**
The flange kit is utilized when the power section is mounted through the back panel of an enclosure. Includes flange mount brackets and NEMA Type 12/IP54 fan components. Metal shroud not included.
Flange kits for NEMA Type 12/IP54 enclosure drive rating are determined by rating of drive.
**Flange Kit NEMA Type 12/ IP54—Frames 4–9**
|are determined by rating of<br>drive.<br>**Flange Kit NEMA Type 12/**<br>**IP54— Frames 4, 5 and 6**1<br>**Frame**<br>**Size**<br>**Delivery**<br>**Code**<br>**Catalog**<br>**Number**<br>FR4<br>W<br>**OPTTHRFR4**<br>FR5<br>**OPTTHRFR5**<br>FR6<br>**OPTTHRFR6**|**Frame**<br>**Size**<br>**Delivery**<br>**Code**|**Catalog**<br>**Number**|
|---|---|---|
||FR4<br>FP<br>FR5<br>FR6<br>FR7<br>FR8<br>FR9|**OPTTHR4**|
|||**OPTTHR5**|
|||**OPTTHR6**|
|||**OPTTHR7**|
|FR4<br>W<br>FR5<br>FR6|||
|||**OPTTHR8**|
|||**OPTTHR9**|
## _**Note**_
> 1 For installation of an SPX9000 NEMA Type 1/IP21 drive into a NEMA Type 12/IP54 oversized enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-166**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Options**
## **9000X Series Option Board Kits**
The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is designed to accept a total of five option boards.
**2**
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2 relay output board, which are installed in slots A and B.
## **Option Boards**
## **Option Board Kits**
|A<br>B C D E|**Option Kit Description**1<br>**Allowed Slot**<br>**Locations**2<br>**Field**<br>**Installed**<br>**Factory**<br>**Installed**<br>**SVX Ready Programs**<br>**Catalog**<br>**Number**<br>**Option**<br>**Designator**<br>**Basic**<br>**Local/**<br>**Remote**<br>**Standard**<br>**MSS**<br>**PID**<br>**Multi-P.**<br>**PFC**|
|---|---|
||**Standard I/O Cards**|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/EXT +24 Vdc<br>A<br>**OPTA9**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||2 RO (NC-NO)<br>B<br>**OPTA2**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||**Extended I/O Cards**|
||2 RO, therm<br>B<br>**OPTA3**<br>**A3**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Encoder low volt +5V/15V/24V<br>C<br>**OPTA4**<br>**A4**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Encoder high volt +15V/24V<br>C<br>**OPTA5**<br>**A5**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Double encoder—SPX only<br>C<br>**OPTA7**<br>**A7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 DO, 2 AI, 1 AO<br>A<br>**OPTA8**<br>**A8**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/EXT +24 Vdc<br>A<br>**OPTA1**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||3 DI (encoder 10–24V), out +15V/+24V,<br>2 DO (pulse+direction)—SPX only<br>C<br>**OPTAE**<br>**AE**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/EXT +24 Vdc<br>A<br>**OPTAFA1**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 ext +24 Vdc/EXT +24 Vdc<br>B, C,**D**, E<br>**OPTB1**<br>**B1**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 RO (NC-NO), 1 RO (NO), 1 therm<br>B, C,**D**, E<br>**OPTB2**<br>**B2**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 AI (mA isolated), 2 AO (mA isolated),<br>1 ext +24 Vdc/EXT +24 Vdc<br>B, C,**D**, E<br>**OPTB4**<br>**B4**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||3 RO (NO)<br>B, C,**D**, E<br>**OPTB5**<br>**B5**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>B, C,**D**, E<br>**OPTB8**<br>**B8**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||1 RO (NO), 5 DI 42–240 Vac input<br>B, C,**D**, E<br>**OPTB9**<br>**B9**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||SPI, absolute encoder<br>C<br>**OPTBB**<br>**BB**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||**Communication Cards**|
||Modbus3<br>D,**E**<br>**OPTC2**<br>**C2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Johnson Controls N23<br>D,**E**<br>**OPTC2**<br>**CA**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||Modbus TCP<br>D,**E**<br>**OPTCI**<br>**CI**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||BACnet<br>D,**E**<br>**OPTCJ**<br>**C4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||EtherNet/IP<br>D,**E**<br>**OPTCQ**<br>**CQ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP<br>D,**E**<br>**OPTC3**<br>**C3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||LonWorks<br>D,**E**<br>**OPTC4**<br>**C4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP (D9 connector)<br>D,**E**<br>**OPTC5**<br>**C5**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||CANopen (slave)<br>D,**E**<br>**OPTC6**<br>**C6**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||DeviceNet<br>D,**E**<br>**OPTC7**<br>**C7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Modbus (D9 type connector)<br>D,**E**<br>**OPTC8**<br>**C8**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Adapter—SPX only<br>D,**E**<br>**OPTD1**<br>**D1**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Adapter—SPX only<br>D,**E**<br>**OPTD2**<br>**D2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||RS-232 with D9 connection<br>D,**E**<br>**OPTD3**<br>**D3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
## _**Notes**_
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
- 2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
- 3 OPTC2 is a multi-protocol option card.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-167**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## _**Modbus RTU Network Communications**_
The Modbus Network Card **2** OPTC2 is used for connecting the 9000X Drive as a slave on **2** a Modbus network. The interface is connected by a **2** 9-pin DSUB connector (female) and the baud rate ranges from 300 to 19200 **2** baud. Other communication parameters include an **2** address range from 1 to 247; a parity of None, Odd or **2** Even; and the stop bit is 1.
## _**PROFIBUS Network Communications**_
The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS-DP network. The interface is connected by a 9-pin DSUB connector (female). The baud rates range from 9.6K baud to 12M baud, and the addresses range from 1 to 127.
## _**LonWorks Network Communications**_
The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network. This interface uses Standard Network Variable Types (SNVT) as data types. The channel connection is achieved using a FTT-10A Free Topology transceiver via a single twisted transfer cable. The communication speed with LonWorks is 78 kBits/s.
## _**CANopen (Slave) Communications**_
The CANopen (Slave) Network Card OPTC6 is used for connecting the 9000X Drive to a host system. According to ISO11898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms, and specific line delay of nominal 5 nS/m. 120 ohms line termination resistors required for installation.
## _**DeviceNet Network Communications**_
The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network. It includes a 5.08 mm pluggable connector. Transfer method is via CAN using a two-wire twisted shielded cable with two-wire bus power cable and drain. The baud rates used for communication include 125K baud, 250K baud and 500K baud.
## _**Johnson Controls Metasys N2 Network Communications**_
The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. The N2 fieldbus is available as a factory installed option and as a field installable kit.
## _**Modbus/TCP Network Communications**_
The Modbus/TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks utilizing Modbus protocol. It includes an RJ-45 pluggable connector. This interface provides a selection of standard and custom register values to communicate drive parameters. The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable over Ethernet using a supplied software tool.
## _**BACnet Network Communications**_
The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks. It includes a 5.08 mm pluggable connector. Data transfer is Master-Slave/ Token Passing (MS/TP) RS-485. This interface uses a collection of 30 Binary Value Objects (BVOs) and 35 Analog Value Objects (AVOs) to communicate drive parameters. The card supports 9.6, 19.2 and 38.4 Kbaud communication speeds and supports network addresses 1–127.
## _**EtherNet/IP Network Communications**_
The EtherNet/IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet/Industrial Protocol networks. It includes an RJ-45 pluggable connector. The interface uses CIP objects to communicate drive parameters (CIP is “Common Industrial Protocol”, the same protocol used by DeviceNet). The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable by Static, BOOTP and DHCP methods.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-168**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Control Panel Options**
## **Factory Options**
|**Factory Options**|||
|---|---|---|
||**Factory Installed**|**Field Installed**|
|||**NEMA Type 1/IP21**|
|**Description**|**Option Code**|**Catalog Number**|
|**Local/Remote Keypad SVX9000 Control Panel—**This option is standard on all drives and|**A**|**KEYPAD-LOC/REM**|
|consists of an RS-232 connection, backlit alphanumeric LCD display with nine indicators for the|||
|RUN status and two indicators for the control source. The nine pushbuttons on the panel are used|||
|for panel programming and monitoring of all SVX9000 parameters. The panel is detachable and|||
|isolated from the input line potential. Include LOC/REM key to choose control location.|||
|**Keypad Remote Mounting Kit—**This option is used to remote mount the SVX9000 keypad. The|**—**|**OPTRMT-KIT-9000X**|
|footprint is compatible to the SV9000 remote mount kit. Includes 10 ft cable, keypad holder and|||
|mounting hardware.|||
|**Keypad Blank—**9000X Series select keypad for use with special and custom applications.|**—**|**KEYPAD-BLANK**|
|**Miscellaneous Options**|||
|**Description**||**Catalog Number**|
|**9000XDrive**—A PC-based tool for controlling and monitoring of the SVX9000. Features include: loading parameters that||**9000XDRIVE**|
|can be saved to a file or printed, setting references, starting and stopping the motor, monitoring signals in graphical or text|||
|form, and real-time display. To avoid damage to the drive or computer, SVDrivecable must be used.|||
|**SVDrivecable**—6 ft (1.8m) RS-232 cable (22 gauge) with a 7-pin connector on each end. Should be used in conjunction||**SVDRIVECABLE**|
|with the 9000XDrive option to avoid damage to the SVX9000 or computer. The same cable can be used for downloading|||
|specialized applications to the drive.|||
|**External Dynamic Braking Resistors**—Used with the dynamic braking chopper circuit to absorb motor regenerative||See**Page V6-T2-170**|
|energy for stopping the load and to dissipate the energy flowing back into the drive. Resistors are separated into standard|||
|duty and heavy-duty. Standard duty is defined as 20% duty or less with 100% braking torque, while heavy-duty is defined as|||
|50% duty or less with 150% braking torque.|||
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-169**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **SPX9000 Drive Options**
**2**
## **Brake Chopper Options**
The brake chopper circuit option is used for applications that require dynamic braking. Dynamic braking resistors are not included with drive purchase. Consult the factory for additional dynamic braking resistor selections that are supplied separately. A list of common resistors are listed below and are complete indoor assemblies, include a pre-wired terminal block and a thermal switch, and are not UL Listed.
## _**Duty Cycle**_
The duty cycle rating is based on a 60-second period. For example, the 20% duty cycle resistor can carry 100% current for 12 seconds out of every 60 seconds, while the 50% duty cycle resistor can carry 150% current for 30 seconds out of every 60 seconds.
## _**Torque**_
If the braking torque required is less than 15%, dynamic braking is not required because the regenerated energy will be dissipated in the drive and motor losses.
## **Dynamic Brake Resistor—Catalog Number Selection**
**– – DBR R100 W0800**
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||||||||
||||**Dynamic Brake Resistor**||||**Resistance**||||**Rated Watts**|||
||||||**1D0**= 1.0 Ohms<br>**100**= 100 Ohms|||||**0800**= 800 Watts<br>**8000**= 8000 Watts||||
|||||||||||**080K**= 80,000 Watts||||
|**230V Brake Resistors**||||||||||||||
|**Drive hp**<br>**(CT/IH)**|**Minimum**<br>**Ohms**||**20% Duty Cycle, 100% Torque**<br>**Catalog Number**<br>**Dimensions**||||**50% Duty Cycle, 150% Torque**<br>**(Inches)**<br>**Catalog Number**<br>**Dimensions (Inches)**|||||||
|0.75|30.0||**DBR-R100-W0400**||12W x 5D x 5H<br>**DBR-R100-W0800**|||||||12W x 7D x 5H||
|1|30.0||**DBR-R100-W0400**||12W x 5D x 5H<br>**DBR-R100-W0800**|||||||12W x 7D x 5H||
|1.5|30.0||**DBR-R100-W0400**||12W x 5D x 5H<br>**DBR-R036-W1200**|||||||12W x 10D x 5H||
|2<br>3|30.0<br>30.0||**DBR-R100-W0400**<br>**DBR-R036-W0800**||12W x 5D x 5H<br>**DBR-R036-W1200**<br>12W x 7D x 5H<br>**DBR-R036-W2000**|||||||12W x 10D x 5H<br>12W x 16D x 5H||
|4|30.0||**DBR-R036-W0800**||12W x 7D x 5H<br>**DBR-R030-W2400**|||||||19W x 10D x 5H||
|5|30.0||**DBR-R036-W0800**||12W x 7D x 5H<br>**DBR-R030-W2800**|||||||19W x 13D x 5H||
|7.5|20.0||**DBR-R020-W1200**||12W x 10D|x 5H<br>**DBR-R020-W4800**||||||26.5W x 13D x 5H||
|10|10.0||**DBR-R015-W1600**||12W x 13D|x 5H<br>**DBR-R112-W6000**||||||26.5W x 13D x 5H||
|15|10.0||**DBR-R012-W2400**||19W x 10D|x 5H<br>**DBR-R010-W9000**||||||28W x 10D x 10H||
|20<br>25|3.3<br>3.3||**DBR-R9D3-W3200**<br>**DBR-R5D5-W4000**||19W x 10D x 5H<br>**DBR-R3D4-W012K**<br>26.5W x 10D x 5H<br>**DBR-R5D1-W015K**|||||||28W x 10D x 10H<br>28W x 16D x 10H||
|30|3.3||**DBR-R4D8-W4800**||26.5W x 10D x 5H<br>**DBR-R4D1-W020K**|||||||28W x 16D x 10H||
|40|1.4||**DBR-R004-W6000**||26.5W x 13D x 5H<br>**DBR-R3D4-W025K**|||||||30W x 18D x 16H||
|50|1.4||**DBR-R3D1-W7500**||26.5W x 16D x 5H<br>**DBR-R2D1-W030K**|||||||30W x 18D x 24H||
|60|1.4||**DBR-R2D8-W9000**||26.5W x 16D x 5H<br>**DBR-R002-W036K**|||||||30W x 18D x 24H||
|75|1.4||**DBR-R2D6-W012K**||28W x 10D|x 10H<br>**DBR-R1D5-W045K**||||||30W x 18D x 32H||
|100|1.4||**DBR-R002-W015K**||28W x 16D|x 10H<br>**DBR-R1D4-W060K**||||||30W x 18D x 40H||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-170**
Adjustable Frequency Drives
2.7
SPX9000 Drives
**480V Brake Resistors**
|**Drive hp**|**Minimum**|**20% Duty Cycle, 100%**|**Torque**|**50% Duty Cycle, 150%**|**Torque**|
|---|---|---|---|---|---|
|**(CT/IH)**|**Ohms**|**Catalog Number**|**Dimensions (Inches)**|**Catalog Number**|**Dimensions (Inches)**|
|1|63.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W0800**|12W x 7D x 5H|
|1.5|63.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W1200**|12W x 10D x 5H|
|2|63.0|**DBR-R100-W0400**|12W x 5D x 5H|**DBR-R100-W1200**|12W x 10D x 5H|
|3|63.0|**DBR-R100-W0800**|12W x 7D x 5H|**DBR-R100-W2000**|12W x 16D x 5H|
|5|63.0|**DBR-R100-W0800**|12W x 7D x 5H|**DBR-R100-W2800**|19W x 13D x 5H|
|6|63.0|**DBR-R100-W1200**|12W x 10D x 5H|**DBR-R070-W4000**|19W x 16D x 5H|
|7.5|63.0|**DBR-R100-W1200**|12W x 10D x 5H|**DBR-R063-W4800**|26.5W x 13D x 5H|
|10|63.0|**DBR-R063-W1600**|12W x 13D x 5H|**DBR-R063-W6000**|26.5W x 16D x 5H|
|15|42.0|**DBR-R042-W2400**|19W x 10D x 5H|**DBR-R042-W9000**|28W x 10D x 10H|
|20|21.0|**DBR-R030-W3200**|19W x 13D x 5H|**DBR-R023-W012K**|28W x 13D x 10H|
|25|21.0|**DBR-R030-W4000**|19W x 16D x 5H|**DBR-R021-W015K**|28W x 13D x 10H|
|30|14.0|**DBR-R020-W4800**|26.5W x 13D x 5H|**DBR-R014-W020K**|30W x 18D x 24H|
|40|6.5|**DBR-R112-W6000**|26.5W x 13D x 5H|**DBR-R007-W025K**|30W x 18D x 16H|
|50|6.5|**DBR-R013-W7500**|26.5W x 16D x 5H|**DBR-R8D5-W030K**|30W x 18D x 24H|
|60|6.5|**DBR-R010-W9000**|28W x 10D x 10H|**DBR-R7D3-W036K**|30W x 18D x 24H|
|75|3.3|**DBR-R009-W012K**|28W x 13D x 10H|**DBR-R3D3-W045K**|30W x 18D x 32H|
|100|3.3|**DBR-R5D1-W015K**|28W x 16D x 10H|**DBR-R004-W060K**|30W x 18D x 40H|
|125|3.3|**DBR-R4D1-W020K**|28W x 16D x 10H|**DBR-R004-W070K**|30W x 18D x 48H|
|150|3.3|**DBR-R3D4-W025K**|30W x 18D x 16H|**DBR-R3D5-W085K**|30W x 18D x 56H|
|200|3.3|**DBR-R3D3-W030K**|30W x 18D x 24H|**DBR-R3D3-W110K**|30W x 18D x 72H|
|250|1.4|**DBR-R2D5-W036K**|30W x 18D x 24H|1|—|
|300|1.4|**DBR-R1D5-W045K**|30W x 18D x 32H|1|—|
|350|1.4|**DBR-R1D4-W060K**|30W x 18D x 40H|1|—|
|400|0.9|**DBR-R1D4-W060K**|30W x 18D x 40H|1|—|
|500|0.9|**DBR-R0D9-W080K**|30W x 18D x 48H|1|—|
|550|0.9|**DBR-R001-W085K**|30W x 18D x 56H|1|—|
**2**
## _**Note**_
> 1 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-171**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **575V Brake Resistors**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**e essos**<br>**Drive hp**<br>**(CT/IH)**<br>**Minimum**<br>**Ohms**<br>**20% Duty Cycle, 100% Torque**<br>**50% Duty Cycle, 150% Torque**<br>**Catalog Number**<br>**Dimensions (Inches)**<br>**Catalog Number**<br>**Dimensions (Inches)**|
|---|---|
||2<br>100.0<br>**DBR-R100-W0400**<br>12W x 5D x 5H<br>**DBR-R100-W1200**<br>12W x 10D x 5H|
||3<br>100.0<br>**DBR-R100-W0800**<br>12W x 7D x 5H<br>**DBR-R100-W2000**<br>12W x 16D x 5H|
||4<br>100.0<br>**DBR-R100-W0800**<br>12W x 7D x 5H<br>**DBR-R100-W2400**<br>19W x 10D x 5H|
||5<br>100.0<br>**DBR-R100-W0800**<br>12W x 7D x 5H<br>**DBR-R100-W2800**<br>19W x 13D x 5H|
||7.5<br>100.0<br>**DBR-R100-W1200**<br>12W x 10D x 5H<br>**DBR-R100-W4800**<br>26.5W x 13D x 5H|
||10<br>30.0<br>**DBR-R063-W1600**<br>12W x 13D x 5H<br>**DBR-R063-W6000**<br>26.5W x 16D x 5H|
||15<br>30.0<br>**DBR-R042-W2400**<br>19W x 10D x 5H<br>**DBR-R042-W9000**<br>28W x 10D x 10H|
||20<br>30.0<br>**DBR-R030-W3200**<br>19W x 13D x 5H<br>**DBR-R030-W012K**<br>28W x 13D x 10H|
||25<br>30.0<br>**DBR-R030-W4000**<br>19W x 16D x 5H<br>**DBR-R030-W015K**<br>28W x 16D x 10H|
||30<br>18.0<br>**DBR-R020-W4800**<br>26.5W x 13D x 5H<br>**DBR-R020-W020K**<br>30W x 18D x 16H|
||40<br>18.0<br>**DBR-R030-W6000**<br>26.5W x 16D x 5H<br>**DBR-R184-W025K**<br>30W x 18D x 16H|
||50<br>9.0<br>**DBR-R013-W7500**<br>26.5W x 16D x 5H<br>**DBR-R012-W030K**<br>30W x 18D x 24H|
||60<br>9.0<br>**DBR-R010-W9000**<br>28W x 10D x 10H<br>**DBR-R010-W036K**<br>30W x 18D x 24H|
||75<br>9.0<br>**DBR-R009-W012K**<br>28W x 13D x 10H<br>**DBR-R009-W045K**<br>30W x 18D x 24H|
||100<br>7.0<br>**DBR-R013-W015K**<br>28W x 16D x 10H<br>**DBR-R8D4-W060K**<br>30W x 18D x 40H|
||125<br>7.0<br>**DBR-R8D2-W020K**<br>30W x 18D x 10H<br>**DBR-R007-W070K**<br>30W x 18D x 40H|
||150<br>7.0<br>**DBR-R007-W025K**<br>30W x 18D x 16H<br>**DBR-R006-W085K**<br>30W x 18D x 56H|
||175<br>7.0<br>**DBR-R007-W030K**<br>30W x 18D x 24H<br>**DBR-R007-W100K**<br>30W x 18D x 72H|
||200<br>2.5<br>**DBR-R3D3-W030K**<br>30W x 18D x 24H<br>**DBR-R2D6-W110K**<br>30W x 18D x 64H|
||250<br>2.5<br>**DBR-R2D5-W036K**<br>30W x 18D x 24H<br>**DBR-R003-W140K**<br>30W x 18D x 72H|
||300<br>2.5<br>**DBR-R3D3-W045K**<br>30W x 18D x 32H<br>1<br>—|
||400<br>1.7<br>**DBR-R002-W060K**<br>30W x 18D x 48H<br>1<br>—|
||450<br>1.7<br>**DBR-R1D8-W070K**<br>30W x 18D x 48H<br>1<br>—|
||500<br>1.7<br>**DBR-R002-W080K**<br>30W x 18D x 56H<br>1<br>—|
## _**Note**_
> 1 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-172**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## _**Control/Communication Options**_
## **Available Control/Communications Options**
|**Option**|**Description**|**Option Type**|
|---|---|---|
|**K2**|**Door-Mounted Speed Potentiometer with HOA Selector Switch**—Provides the SPX9000 with the ability to start/stop and adjust the speed reference from<br>door-mounted control devices or remotely from customer supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-mounted|Control|
||speed potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry||
||contact and 4–20 mA signal.||
|**K4**|**HAND/OFF/AUTO Switch for Non-Bypass Configurations**—Provides a three-position selector switch that allows the user to select either a HAND or AUTO|Control|
||mode of operation. HAND mode is defaulted to keypad operation, and AUTO mode is defaulted to control from an external terminal source. These modes of operation<br>can be configured via programming to allow for alternate combinations of start and speed sources. Start and speed sources include keypad, I/O and fieldbus.||
|**KB**<br>**L1**|**115V Control Transformer, 550 VA**—Provides a fused control power transformer with additional 550 VA at 115V for customer use.<br>**Power On and Fault Pilot Lights**—Provide a white power on light that indicates power to the enclosed cabinet and a red fault light that indicates a drive fault|Control<br>Light|
||has occurred.||
|**P2**|**Disconnect Switch**—Disconnect switch option is applicable only with NEMA Type 1/IP21 and NEMA Type 12/IP54 Freestanding drives. Allows a convenient|Input|
||means of disconnecting the SPX9000 from the line, and the operating mechanism can be padlocked in the OFF position. This is factory-mounted in the enclosure.||
**2**
## _**SPX Freestanding Options**_
**480V and 690V Control Options, 200–550 hp**[1]
||**Catalog Number**|
|---|---|
|**Description**<br>Door-mounted speed potentiometer with HOA selector switch|**Suffix**<br>**K2**|
|HAND/OFF/AUTO switch (22 mm)|**K4**|
|115 volt control transformer 550 VA|**KB**|
**480V and 690V Light Options, 200–550 hp**[1]
||**Catalog Number**|
|---|---|
|**Description**|**Suffix**|
|Power on/fault pilot lights|**L1**|
## **Input Options, 200–550 hp**[1]
|**Description**|**Catalog Number**<br>**Suffix**|
|---|---|
|Disconnect switch|**P2**2|
## _**Notes**_
> 1 Consult factory for adder information.
> 2 Applicable with FR10 and FR11 freestanding designs only.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-173**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Replacement Parts**
**2**
## **FR4 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|NEMA Type 12 control fan1|1<br>**PP01086**<br>**PP01086**<br>**—**|
|Control module2|SPX control module|1<br>**CPBS0000000000**<br>**CPBS0000000000**<br>**—**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**—**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**—**|
|Converter|Power board3|1<br>**VB00308-0004-2**<br>**VB00208-0003-5**<br>**—**|
|||1<br>**VB00308-0007-2**<br>**VB00208-0004-5**<br>**—**|
|||1<br>**VB00308-0008-2**<br>**VB00208-0005-5**<br>**—**|
|||1<br>**—**<br>**VB00208-0007-5**<br>**—**|
|||1<br>**—**<br>**VB00208-0009-5**<br>**—**|
|||1<br>**—**<br>**VB00410-0012-5-ARV**<br>**—**|
|Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**—**|
|Main fan2|DC fan (main)|1<br>**PP01060**<br>**PP01060**<br>**—**|
|Other|Mounting kit, fixing kit|1<br>**FR00040**<br>**FR00040**<br>**—**|
||Mounting kit, fixing kit, N121|1<br>**FR00079**<br>**FR00079**<br>**—**|
||Control cover, plastic, N1|1<br>**FR00006**<br>**FR00006**<br>**—**|
## **FR5 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|NEMA Type 12 control fan1|1<br>**PP01088**<br>**PP01088**<br>**—**|
|Control module2|SPX control module|1<br>**CPBS0000000000**<br>**CPBS0000000000**<br>**—**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**—**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**—**|
|Converter|Power board3|1<br>**VB00313-0017-2**<br>**VB00213-0016-5**<br>**—**|
|||1<br>**VB00313-0025-2**<br>**VB00213-0022-5**<br>**—**|
|||1<br>**VB00313-0031-2**<br>**VB00213-0031-5**<br>**—**|
|Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**—**|
|Main fan2|DC fan (main)|1<br>**PP01061**<br>**PP01061**<br>**—**|
|Other|Mounting kit, fixing kit|1<br>**FR00050**<br>**FR00050**<br>**—**|
||Mounting kit, fixing kit, N121|1<br>**FR00081**<br>**FR00081**<br>**—**|
||Control cover, plastic, N1|1<br>**FR05011**<br>**FR05011**<br>**—**|
## _**Notes**_
> 1 Only for NEMA Type 12/IP54 Type drives.
- 2 Factory recommended spare parts.
> 3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-174**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **FR6 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|NEMA Type 12 control fan1|1<br>**PP01049**<br>**PP01049**<br>**—**|
|Control module2|SPX control module|1<br>**CPBS0000000000**<br>**CPBS0000000000**<br>**CPBS0000000000**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power board3|1<br>**VB00316-0048-2**<br>**VB00416-0038-5**<br>**VB00404-0004-6**|
|||1<br>**VB00316-0061-2**<br>**VB00416-0045-5**<br>**VB00404-0005-6**|
|||1<br>**—**<br>**VB00416-0061-5**<br>**VB00404-0007-6**|
|||1<br>**—**<br>**—**<br>**VB00404-0010-6**|
|||1<br>**—**<br>**—**<br>**VB00404-0013-6**|
|||1<br>**—**<br>**—**<br>**VB00404-0018-6**|
|||1<br>**—**<br>**—**<br>**VB00404-0022-6**|
|||1<br>**—**<br>**—**<br>**VB00404-0027-6**|
|||1<br>**—**<br>**—**<br>**VB00404-0034-6**|
|DC section|Bus capacitor|2<br>**—**<br>**—**<br>**S00930**|
|Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main fan2|DC fan (main)|1<br>**PP01062**<br>**PP01062**<br>**—**|
|Other|Mounting kit, fixing kit|1<br>**FR00060**<br>**FR00060**<br>**FR00060**|
||Mounting kit, fixing kit, N121|1<br>**FR00082**<br>**FR00082**<br>**FR00082**|
||Control cover, plastic, N1|1<br>**FR06011**<br>**FR06011**<br>**FR06011**|
**2**
## **FR7 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|NEMA Type 12 control fan1|1<br>**PP01049**<br>**PP01049**<br>**PP01049**|
|Control module2|SPX control module|1<br>**CPBS0000000000**<br>**CPBS0000000000**<br>**CPBS0000000000**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power board3|1<br>**VB00319-0075-2**<br>**VB00619-0072-5**<br>**VB00419-0041-6**|
|||1<br>**VB00319-0088-2**<br>**VB00619-0087-5**<br>**VB00419-0052-6**|
|||1<br>**VB00319-0114-2**<br>**VB00619-0105-5**<br>**—**|
|DC section|Bus capacitor|2<br>**—**<br>**—**<br>**PP01041**|
|Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main fan2|DC fan (main)|1<br>**PP01063**<br>**PP01063**<br>**PP01063**|
|Other|Mounting kit, fixing kit|1<br>**FR07071**<br>**FR07071**<br>**FR07071**|
||Mounting kit, fixing kit, N121|1<br>**FR07072**<br>**FR07072**<br>**FR07072**|
||Control cover, plastic, N1|1<br>**FR07011**<br>**FR07011**<br>**FR07011**|
## _**Notes**_
- 1 Only for NEMA Type 12/IP54 Type drives.
- 2 Factory recommended spare parts.
> 3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-175**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **FR8 Spare Parts**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**pe**<br>**Category**|**s**<br>**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|---|
||Control fan|NEMA Type 12 control fan1|1<br>**CP01180**<br>**CP01180**<br>**CP01180**|
||Control module2|SPX control module|1<br>**CPBS0000000000**<br>**CPBS0000000000**<br>**CPBS0000000000**|
|||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**OPTA9**|
|||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**OPTA2**|
||Converter|Power board3|1<br>**VB00722-0140-2-ANV**<br>**VB00636-0140-4-ANV**<br>**VB00422-0062-5-ANV**|
||||1<br>**VB00722-0170-2-ANV**<br>**VB00636-0168-4-ANV**<br>**VB00422-0080-5-ANV**|
||||1<br>**VB00722-0205-2-ANV**<br>**VB00636-0205-4-ANV**<br>**VB00422-0100-5-ANV**|
|||IGBT|2<br>**PP01175**<br>**PP01175**<br>**PP01127**|
||DC section|Bus capacitor|4<br>**S00335**<br>**S00335**<br>**PP01041**|
||Inverter|Diode|3<br>**CP01268**<br>**CP01268**<br>**CP01373**|
|||Rectifier board|1<br>**VB00227**<br>**VB00227**<br>**VB00427**|
||Keypad2|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
||Main AC fan|Fan AC|1<br>**PP01123**<br>**PP01123**<br>**PP01123**|
|||Fan fuse|2<br>**PP20202**<br>**PP20202**<br>**PP20202**|
|||Starting cap|1<br>**S00734**<br>**S00734**<br>**S00734**|
|||Fan driver board AC|1<br>**VB00599**<br>**VB00799**<br>**VB00799**|
|||Isolation transformer (fan)|1<br>**S0000113**<br>**S0000113**<br>**S0000113**|
||Main DC fan2|DC fan|1<br>**PP00071**<br>**PP00071**<br>**PP00071**|
|||DC power supply|1<br>**S01016**<br>**S01016**<br>**S01016**|
||Other|Front cover, N121|1<br>**FR08079**<br>**FR08079**<br>**FR08079**|
|||Conduit plate, N12|1<br>**FR08082**<br>**FR08082**<br>**FR08082**|
|||Front cover, N1|1<br>**FR08106**<br>**FR08106**<br>**FR08106**|
## _**Notes**_
> 1 Only for NEMA Type 12/IP54 Type drives.
> 2 Factory recommended spare parts.
> 3 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-176**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **FR9 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control fan|50 mm fan|1<br>**PP09041**<br>**PP09041**<br>**PP09041**|
||80 mm fan|1<br>**PP01068**<br>**PP01068**<br>**PP01068**|
|Control module1|SPX control module|1<br>**CPBS0000000000**<br>**CPBS0000000000**<br>**CPBS0000000000**|
||Standard slot A I/O card|1<br>**OPTA9**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**OPTA2**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power module2|1<br>**FR09-0261-2-ANV**<br>**FR09-0261-4-ANV**<br>**FR09-0125-5-ANV**|
|||1<br>**FR09-0300-2-ANV**<br>**FR09-0300-4-ANV**<br>**FR09-0144-5-ANV**|
|||1<br>**—**<br>**—**<br>**FR09-0170-5-ANV**|
||Driver board|1<br>**S00583**<br>**S00583**<br>**S00583**|
||Shunt board2|6<br>**—**<br>**VB00535**<br>**VB00537**|
|||6<br>**—**<br>**VB00536**<br>**VB00542**|
|||6<br>**—**<br>**—**<br>**VB00543**|
|DC section|Balancing resistor|3<br>**PP00052**<br>**PP00052**<br>**PP00052**|
||Bus capacitor|8<br>**S00335**<br>**S00335**<br>**PP01041**|
||DC busbars DC–|1<br>**FR09043**<br>**FR09043**<br>**FR09043**|
||DC busbars DC+|1<br>**FR09044**<br>**FR09044**<br>**FR09044**|
||DC busbars connection|1<br>**FR09045**<br>**FR09045**<br>**FR09045**|
||DC busbars +/– insulator|1<br>**FR09046**<br>**FR09046**<br>**FR09046**|
||DC busbars –/con insulator|1<br>**FR09047**<br>**FR09047**<br>**FR09047**|
|Inverter|Rectifier module|1<br>**FR09826**<br>**FR09822**<br>**FR09823**|
||Diode|3<br>**CP01268**<br>**CP01268**<br>**CP01268**|
||Rectifier board|1<br>**—**<br>**VB00459**<br>**VB00460**|
|Keypad1|SVX/SPX keypad|1<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main AC fan|Fan AC|1<br>**PP01080**<br>**PP01080**<br>**PP01080**|
||Fan fuse|2<br>**PP20202**<br>**PP20202**<br>**PP20202**|
||Starting cap|1<br>**S00465**<br>**S00465**<br>**S00465**|
||Fan driver board AC|1<br>**VB00899**<br>**VB00399**<br>**VB00299**|
||Isolation transformer (fan)|1<br>**PP09056**<br>**PP09055**<br>**PP09055**|
|Main DC fan1|DC fan|1<br>**PP00072**<br>**PP00072**<br>**PP00072**|
||DC power supply|1<br>**S01017**<br>**S01017**<br>**S01017**|
|Other|Front cover power|1<br>**FR09012**<br>**FR09012**<br>**FR09012**|
||Front cover connection|1<br>**FR09013**<br>**FR09013**<br>**FR09013**|
||Front power conduit|1<br>**FR09014**<br>**FR09014**<br>**FR09014**|
**2**
## _**Notes**_
- 1 Factory recommended spare parts.
- 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-177**
Adjustable Frequency Drives
SPX9000 Drives
## 2.7
## **FR10 Spare Parts**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**pe**<br>**Category**|**s**<br>**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|---|
||Control|Fiber board|1<br>**—**<br>**S00451**<br>**S00451**|
|||ASIC board|1<br>**—**<br>**S00457**<br>**S00457**|
||Control fan|ASIC fan|1<br>**—**<br>**PP01096**<br>**PP01096**|
||Control module1|SPX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
|||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
|||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
||Converter|Power module2|1<br>**—**<br>**FR10-0385-4-ANV**<br>**FR10-0261-5-ANV**|
||||1<br>**—**<br>**FR10-0460-4-ANV**<br>**FR10-0325-5-ANV**|
||||1<br>**—**<br>**FR10-0520-4-ANV**<br>**FR10-0385-5-ANV**|
||||1<br>**—**<br>**—**<br>**FR10-0416-5-ANV**|
|||Driver board|1<br>**—**<br>**S00450**<br>**S00450**|
|||Driver adapter board|1<br>**—**<br>**VB00330**<br>**VB00330**|
|||Shunt board2|6<br>**—**<br>**VB00497**<br>**VB00510**|
||||6<br>**—**<br>**VB00498**<br>**VB00511**|
||||6<br>**—**<br>**VB00537**<br>**VB00545**|
||Covers|Top cover|1<br>**—**<br>**FR10340**<br>**FR10340**|
|||Side cover|2<br>**—**<br>**FR10341**<br>**FR10341**|
||DC section|Balancing resistor|2<br>**—**<br>**PP13027**<br>**PP13028**|
|||DC busbars kit (right)|1<br>**—**<br>**S0000005**<br>**S0000005**|
|||Bus capacitor|12<br>**—**<br>**S00335**<br>**S00336**|
||Inverter|Rectifier module|1<br>**—**<br>**FR10823**<br>**FR10823**|
|||Charging resistor|1<br>**—**<br>**PP00066**<br>**PP00066**|
|||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
|||Rectifier board|1<br>**—**<br>**S00591**<br>**S00592**|
||Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
||Main AC fan|Fan assembly (left)|1<br>**—**<br>**FR10846**<br>**FR10846**|
|||Fan assembly (right)|1<br>**—**<br>**FR10847**<br>**FR10847**|
|||Fan AC|2<br>**—**<br>**PP01080**<br>**PP01080**|
|||Fan fuse|4<br>**—**<br>**PP20202**<br>**PP20202**|
|||Starting cap|2<br>**—**<br>**S00528**<br>**S00528**|
|||Fan driver board AC|2<br>**—**<br>**VB00299**<br>**VB00299**|
|||Isolation transformer (left)|1<br>**—**<br>**FR10844**<br>**FR10844**|
|||Isolation transformer (right)|1<br>**—**<br>**FR10845**<br>**FR10845**|
||Main DC fan1|DC fan|2<br>**—**<br>**PP00072**<br>**PP00072**|
|||DC power supply|2<br>**—**<br>**S01017**<br>**S01017**|
## _**Notes**_
> 1 Factory recommended spare parts.
- 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-178**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **FR11 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control|Fiber board|1<br>**—**<br>**S00451**<br>**S00451**|
||ASIC board|1<br>**—**<br>**S00457**<br>**S00457**|
|Control fan|ASIC fan|1<br>**—**<br>**PP01096**<br>**PP01096**|
|Control module1|SPX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power module2|1<br>**—**<br>**FR11-0590-4-ANV**<br>**FR11-0460-5-ANV**|
|||1<br>**—**<br>**FR11-0650-4-ANV**<br>**FR11-0502-5-ANV**|
|||1<br>**—**<br>**FR11-0730-4-ANV**<br>**FR11-0590-5-ANV**|
||Driver board|1<br>**—**<br>**S00452**<br>**S00452**|
||Driver adapter board|1<br>**—**<br>**VB00330**<br>**VB00330**|
||Shunt board2|9<br>**—**<br>**VB00513**<br>**VB00512**|
|||9<br>**—**<br>**VB00514**<br>**VB00546**|
|||9<br>**—**<br>**VB00538**<br>**VB00547**|
|Covers|Top cover|1<br>**—**<br>**FR11345**<br>**FR11345**|
|DC section|Balancing resistor|3<br>**—**<br>**PP13027**<br>**PP13027**|
||DC busbars kit (right)|3<br>**—**<br>**S0000005**<br>**S0000005**|
||Bus capacitor|18<br>**—**<br>**S00335**<br>**S00335**|
|Inverter|Rectifier module|1<br>**—**<br>**FR10823**<br>**FR10823**|
||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
||Rectifier board|1<br>**—**<br>**S00591**<br>**S00591**|
|Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main AC fan|Fan assembly (right)|3<br>**—**<br>**FR10847**<br>**FR10847**|
||Fan AC|3<br>**—**<br>**PP01080**<br>**PP01080**|
||Fan fuse|4<br>**—**<br>**PP20202**<br>**PP20202**|
||Starting cap|3<br>**—**<br>**S00530**<br>**S00530**|
||Fan driver board AC|3<br>**—**<br>**VB00299**<br>**VB00299**|
||Isolation transformer (right)|3<br>**—**<br>**FR10845**<br>**FR10845**|
|Main DC fan1|DC fan|2<br>**—**<br>**PP00072**<br>**PP00072**|
||DC power supply|2<br>**—**<br>**S01017**<br>**S01017**|
**2**
## _**Notes**_
> 1 Factory recommended spare parts.
> 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-179**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **FR12 Spare Parts**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**pe**<br>**Category**|**s**<br>**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|---|
||Control|Fiber board|2<br>**—**<br>**S00451**<br>**S00451**|
|||ASIC board|2<br>**—**<br>**S00457**<br>**S00457**|
|||Star coupler|1<br>**—**<br>**S00593**<br>**S00593**|
||Control fan|ASIC fan|2<br>**—**<br>**PP01096**<br>**PP01096**|
||Control module1|SPX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
|||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
|||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
||Converter|Power module2|1<br>**—**<br>**FR12-0820-4-ANV**<br>**FR12-0650-5-ANV**|
||||1<br>**—**<br>**FR12-0920-4-ANV**<br>**FR12-0750-5-ANV**|
||||1<br>**—**<br>**FR12-1030-4-ANV**<br>**FR12-0820-5-ANV**|
|||Driver board|2<br>**—**<br>**S00450**<br>**S00450**|
|||Driver adapter board|2<br>**—**<br>**VB00330**<br>**VB00330**|
|||Shunt board|12<br>**—**<br>**VB00498**<br>**VB00511**|
||Covers|Top cover|2<br>**—**<br>**FR10340**<br>**FR10340**|
|||Side cover|4<br>**—**<br>**FR10341**<br>**FR10341**|
||DC section|Balancing resistor|4<br>**—**<br>**PP13027**<br>**PP13027**|
|||DC busbars kit (right)|2<br>**—**<br>**S0000005**<br>**S0000005**|
|||Bus capacitor|24<br>**—**<br>**S00335**<br>**S00336**|
||Inverter|Rectifier module|2<br>**—**<br>**FR10823**<br>**FR10823**|
|||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
|||Rectifier board|2<br>**—**<br>**S00591**<br>**S00591**|
||Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
||Main AC fan|Fan assembly (left)|2<br>**—**<br>**FR10846**<br>**FR10846**|
|||Fan assembly (right)|2<br>**—**<br>**FR10847**<br>**FR10847**|
|||Fan AC|4<br>**—**<br>**PP01080**<br>**PP01080**|
|||Fan fuse|8<br>**—**<br>**PP20202**<br>**PP20202**|
|||Starting cap|4<br>**—**<br>**S00528**<br>**S00528**|
|||Fan driver board AC|4<br>**—**<br>**VB00299**<br>**VB00299**|
|||Isolation transformer (left)|2<br>**—**<br>**FR10844**<br>**FR10844**|
|||Isolation transformer (right)|2<br>**—**<br>**FR10845**<br>**FR10845**|
||Main DC fan1|DC fan|4<br>**—**<br>**PP00072**<br>**PP00072**|
|||DC power supply|4<br>**—**<br>**S01017**<br>**S01017**|
## _**Notes**_
- 1 Factory recommended spare parts.
- 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-180**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **FR13 Spare Parts**
|**Category**|**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|
|Control|ASIC board|1<br>**—**<br>**S00457**<br>**S00457**|
||ASIC assembly|1<br>**—**<br>**60S01030**<br>**60S01030**|
|Control fan|ASIC fan|1<br>**—**<br>**PP01096**<br>**PP01096**|
|Control module1|SPX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
|Converter|Power module2|3<br>**—**<br>**FI13-1150-4-ANV**<br>**FR13-1030-5-ANV**|
|||3<br>**—**<br>**FI13-1300-4-ANV**<br>**FR13-1180-5-ANV**|
|||3<br>**—**<br>**FI13-1450-4-ANV**<br>**FR13-920-5-ANV**|
||Driver board|3<br>**—**<br>**S00454**<br>**S00454**|
||Driver adapter board|2<br>**—**<br>**VB00330**<br>**VB00330**|
||Shunt board2|18<br>**—**<br>**VB00505**<br>**VB00516**|
|||18<br>**—**<br>**VB00514**<br>**VB00517**|
|||18<br>**—**<br>**VB00541**<br>**VB00547**|
|Covers|Top cover|3<br>**—**<br>**FI10001**<br>**FI10001**|
||Side cover|3<br>**—**<br>**FI10003**<br>**FI10003**|
|DC section|Balancing resistor|6<br>**—**<br>**PP13034**<br>**PP13034**|
||Bus capacitor|36<br>**—**<br>**S00335**<br>**S00336**|
||DC busbars kit|3<br>**—**<br>**FI13329**<br>**FI13329**|
|Inverter|Rectifier module|2<br>**—**<br>**FR10823**<br>**FR10823**|
||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
||Rectifier board|2<br>**—**<br>**S00591**<br>**S00591**|
|Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
|Main AC fan|Fan assembly (left)|3<br>**—**<br>**FI13301**<br>**FI13301**|
||Fan AC|3<br>**—**<br>**PP01080**<br>**PP01080**|
||Fan fuse|6<br>**—**<br>**PP20202**<br>**PP20202**|
||Starting cap|3<br>**—**<br>**S00520**<br>**S00520**|
||Fan driver board AC|3<br>**—**<br>**VB00299**<br>**VB00299**|
||Isolation transformer|3<br>**—**<br>**PP10057**<br>**PP10057**|
|Main DC fan1|DC fan|4<br>**—**<br>**PP00072**<br>**PP00072**|
||DC power supply|4<br>**—**<br>**S01017**<br>**S01017**|
**2**
## _**Notes**_
- 1 Factory recommended spare parts.
- 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-181**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **FR14 Spare Parts**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**pe**<br>**Category**|**s**<br>**Description**|**Quantity/**<br>**Drive**<br>**230V**<br>**480V**<br>**575V**<br>**Catalog Number**<br>**Catalog Number**<br>**Catalog Number**|
|---|---|---|---|
||Control|ASIC board|2<br>**—**<br>**S00457**<br>**S00457**|
|||Star coupler|1<br>**—**<br>**S00593**<br>**S00593**|
|||ASIC assembly|2<br>**—**<br>**60S01030**<br>**60S01030**|
|||Star coupler kit|1<br>**—**<br>**FR10860**<br>**FR10860**|
||Control fan|ASIC fan|2<br>**—**<br>**PP01096**<br>**PP01096**|
||Control module1|SPX control module|1<br>**—**<br>**CPBS0000000000**<br>**CPBS0000000000**|
|||Standard slot A I/O card|1<br>**—**<br>**OPTA9**<br>**OPTA9**|
|||Standard slot B I/O card|1<br>**—**<br>**OPTA2**<br>**OPTA2**|
||Converter|Power module2|1<br>**—**<br>**FR14-1770-4-ANV**<br>**FR14-1500-5-ANV**|
||||1<br>**—**<br>**FR14-2150-4-ANV**<br>**FR14-1900-5-ANV**|
||||1<br>**—**<br>**FR14-2700-4-ANV**<br>**FR14-2250-5-ANV**|
|||Driver board|6<br>**—**<br>**S00454**<br>**S00454**|
|||Driver adapter board|2<br>**—**<br>**VB00330**<br>**VB00330**|
|||Shunt board2|36<br>**—**<br>**VB00541**<br>**VB00516**|
||||36<br>**—**<br>**—**<br>**VB00517**|
||Covers|Top cover|6<br>**—**<br>**FI10001**<br>**FI10001**|
|||Side cover|6<br>**—**<br>**FI10003**<br>**FI10003**|
||DC section|Balancing resistor|6<br>**—**<br>**PP13034**<br>**PP13034**|
|||Bus capacitor|72<br>**—**<br>**S00335**<br>**S00336**|
|||DC busbars kit|6<br>**—**<br>**FI13329**<br>**FI13329**|
||Inverter|Rectifier module|2<br>**—**<br>**FR10823**<br>**FR10823**|
|||Diode|3<br>**—**<br>**PP01177**<br>**PP01177**|
|||Rectifier board|2<br>**—**<br>**S00591**<br>**S00591**|
||Keypad1|SVX/SPX keypad|1<br>**—**<br>**KEYPAD-LOC/REM**<br>**KEYPAD-LOC/REM**|
||Main AC fan|Fan assembly (left)|6<br>**—**<br>**FI13301**<br>**FI13301**|
|||Fan AC|6<br>**—**<br>**PP01080**<br>**PP01080**|
|||Fan fuse|12<br>**—**<br>**PP20202**<br>**PP20202**|
|||Starting cap|6<br>**—**<br>**S00520**<br>**S00520**|
|||Fan driver board AC|6<br>**—**<br>**VB00299**<br>**VB00299**|
|||Isolation transformer|6<br>**—**<br>**PP10057**<br>**PP10057**|
||Main DC fan1|DC fan|6<br>**—**<br>**PP00072**<br>**PP00072**|
|||DC power supply|6<br>**—**<br>**S01017**<br>**S01017**|
## _**Notes**_
- 1 Factory recommended spare parts.
- 2 Select one part number based on the amperage rating of the drive. Please contact EatonCare at 877-ETN-CARE for assistance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-182**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Technical Data and Specifications**
## **SPX9000 Drives**
|**SPX9000 Drives**||
|---|---|
|**Description**|**Specification**|
|**Input Ratings**||
|Input voltage (Vin)|+10%/–15%|
|Input frequency (fin)|50/60 Hz (variation up to 45–66 Hz)|
|Connection to power|Once per minute or less (typical operation)|
|High withstand rating|100 kAIC|
|**Output Ratings**||
|Output voltage|0 to Vin|
|Continuous output current|IHrated 100% at 122°F (50°C), FR9 and below|
||ILrated 100% at 104°F (40°C), FR9 and below|
||IH/IL100% at 104°F (40°C), FR10 and above|
|Overload current (IH/IL)|150%IH, 110%ILfor 1 min.|
|Output frequency|0 to 320 Hz|
|Frequency resolution|0.01 Hz|
|Initial output current (IH)|250% for 2 seconds|
|**Control Characteristics**||
|Control method|Frequency control (V/f) Open loop: sensorless vector control|
||Closed loop: frequency control|
||Closed loop: vector control|
|Switching frequency|Adjustable with parameter 2.6.9|
|Frame 4–6|1 to 16 kHz; default 10 kHz|
|Frame 7–12|1 to 10 kHz; default 3.6 kHz|
|Frequency reference|Analog input: Resolution 0.1% (10-bit), accuracy ±1% V/Hz|
||Panel reference: Resolution 0.01 Hz|
|Field weakening point|30 to 320 Hz|
|Acceleration time|0 to 3000 sec.|
|Deceleration time|0 to 3000 sec.|
|Braking torque|DC brake: 30% x Tn(without brake option)|
|**Ambient Conditions**||
|Ambient operating|14°F (–10°C), no frost to 122°F (50°C)IH(FR4–FR9)|
|temperature|14°F (–10°C), no frost to 104°F (40°C)IL(FR10 and up)|
||14°F (–10°C), no frost to 104°F (40°C)IL(all frames)|
|Storage temperature|–40° to 158°F (–40° to 70°C)|
|Relative humidity|0 to 95% RH, noncondensing, non-corrosive,|
||no dripping water|
|Air quality|Chemical vapors: IEC 721-3-3, unit in operation, class 3C2;|
||Mechanical particles: IEC 721-3-3, unit in operation, class 3S2|
|Altitude|100% load capacity (no derating) up to 3280 ft (1000m);|
||1% derating for each 328 ft (100m) above 3280 ft (1000m);|
||max. 9842 ft (3000m)|
|Vibration|EN 50178, EN 60068-2-6; 5 to 50 Hz, displacement amplitude|
||1 mm (peak) at 3 to 15.8 Hz, max. acceleration amplitude|
||1G at 15.8 to 150 Hz|
|Shock|EN 50178, EN 60068-2-27 UPS Drop test (for applicable UPS|
||weights) Storage and shipping: max. 15G, 11 ms (in package)|
|Enclosure class|NEMA 1/IP21 or NEMA 12/IP54, open chassis/IP20|
|**Description**|**Specification**|
|---|---|
|**Control Connections**||
|Analog input voltage|0 to 10V, R = 200 kohms (–10 to 10V joystick control) resolution|
||0.1%; accuracy ±1%|
|Analog input current|0(4) to 20 mA; Ri—250 ohms differential|
|Digital inputs (6)|Positive or negative logic; 18 to 30 Vdc|
|Auxiliary voltage|+24V ±15%, max. 250 mA|
|Output reference voltage|+10V +3%, max. load 10 mA|
|Analog output|0(4) to 20 mA; RLmax. 500 ohms;<br>resolution 10 bit; Accuracy ±2%|
|Digital outputs<br>Relay outputs|Open collector output, 50 mA/48V<br>2 programmable Form C relay outputs|
|**Protections**|switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A|
|Overcurrent protection<br>Overvoltage protection|Trip limit 4.0 x IHinstantaneously<br>Yes|
|Undervoltage protection|Yes|
|Earth fault protection|In case of earth fault in motor or motor cable, only the|
||frequency converter is protected|
|Input phase supervision|Trips if any of the input phases are missing|
|Motor phase supervision|Trips if any of the output phases are missing|
|Overtemperature protection<br>Motor overload protection|Yes<br>Yes|
|Motor stall protection<br>Motor underload protection|Yes<br>Yes|
|Short-circuit protection|Yes (+24V and +10V reference voltages)|
|**High Performance Features**||
|Speed error|<0.01%, depending on the encoder|
|Encoder support<br>Encoder voltages|Incremental or absolute<br>5V (RS-422), 15V or 24V, depending on the option card|
|Torque control|Full torque control at all speeds, including zero|
|Torque accuracy|<2%; <5% down to zero speed|
|Starting torque|>200%, depending on motor and drive sizing|
|Master/slave configurations|Full capability|
|System analysis|Integrated data logger|
|PC communication<br>Inter-drive communication|Fast multiple drive monitoring with PC<br>High-speed bus (12 Mbits/s)|
|High-speed applications|Up to 7200 Hz|
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-183**
Adjustable Frequency Drives
2.7
SPX9000 Drives
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2**
## _**9000X Drives**_
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR4, FR5 and FR6**
||||||**2**<br>**H3**<br>**D1**<br>**D2**<br>EATON<br>W<br><br>H3<br>H2<br>H1<br>D3|EATON<br>W<br><br>H2<br>1|EATON<br>W<br><br>H2<br>1|2<br>1|
|---|---|---|---|---|---|---|---|---|
|||D|||H||||
||||||||||
|**Voltage**<br>**hp (IH)**|||**H1**|**H**|||||
|**FR4**|||||||||
|230V<br>3/4–3|||12.9<br>(327)|12.3<br>(313)<br>11.5<br>(292)<br>7.5<br>(190)<br>3.0<br>(77||||)<br>5.0<br>(126)<br>5.04<br>(128)<br>3.9<br>(100)<br>0.5<br>(13)<br>0.3<br>(7)<br>11.0 (5)<br>3 at 10.1 (28)|
|480V<br>1–5|||||||||
|**FR5**|||||||||
|230V<br>5–7-1/2||||16.0<br>(406)<br>15.3<br>(389)<br>8.4<br>(214)<br>3.9<br>(10||||0)<br>5.8<br>(148)<br>5.7<br>(144)<br>3.9<br>(100)<br>0.5<br>(13)<br>0.3<br>(7)<br>17.9 (8)<br>2 at 1.5 (37)<br>1 at 10.1 (28)|
|**FR6**|||||||||
|230V<br>10–15<br>22.0<br>(558)<br>480V<br>20–30<br>575V<br>2–25||||21.3<br>(541)<br>20.4<br>(519)<br>9.3<br>(237)<br>4.2<br>(10||||<br>5)<br>6.5<br>(165)<br>7.7<br>(195)<br>5.8<br>(148)<br>0.6<br>(15.5)<br>0.4<br>(9)<br>40.8 (19)<br>3 at 1.5 (37)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-184**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54 with Flange Kit, FR4, FR5 and FR6**
|2|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||
||||||||||||
||||||H1<br>H2||||||
||||||||||||
||||||||||||
|H4||||||||||H5<br>D|
||||||||||||
|D2|||||||||||
||||||H3||||||
||||||||||||
|W5<br>|||||H7||||||
|||||**Flange Opening**<br>**FR4 to FR6**||||||W<br>W4|
|||||H||||||H|
|**R4, FR**<br>**1**<br>8|**5 and FR6 with**<br>**W2**<br>**H1**||**Flange Kit**<br>**H2**<br>6|||**H3**<br>**H4**|||**H5**||
|**R4**|||||||||||
|.0 (128)|4.5 (113)<br>13.3 (337)<br>12.8 (325)|||||12.9 (327)<br>1.2 (30)|||0.9 (22)|7.5 (190)<br>3.0 (77)<br>0.3 (7)|
|**R5**|||||||||||
|.6 (143)|4.7 (120)<br>17.0 (434)<br>16.5 (420)|||||16.5 (419)<br>1.4 (36)|||0.7 (18)|8.4 (214)<br>3.9 (100)<br>0.3 (7)|
|**R6**|||||||||||
|.7 (195)|6.7 (170)<br>22.0 (560)<br>21.6 (549)|||||22.0 (558)<br>1.2 (30)|||0.8 (20)|9.3 (237)<br>4.2 (106)<br>0.3 (7)|
|**lange Opening, FR4 to FR6**<br>**3**<br>**W4**<br>**W5**<br>**H6**||||||**H7**<br>**H8**|||**H9**|**Dia. B**<br>0.3 (7)<br>0.3 (7)<br>0.3 (7)|
|**R4**|||||||||||
|.8 (123)<br>4.5 (113)<br>—<br>12.4 (315)||||||12.8 (325)<br>—|||0.2 (5)||
|**R5**|||||||||||
|.3 (135)<br>4.7 (120)<br>—<br>16.2 (410)||||||16.5 (420)<br>—|||0.2 (5)||
|**R6**|||||||||||
|.3 (185)<br>6.7 (170)<br>6.2 (157)<br>21.2 (539)||||||21.6 (549)<br>0.3 (7)|||0.2 (5)||
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-185**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
**NEMA Type 1/IP21 and NEMA Type 12/IP54, FR7**
**==> picture [549 x 382] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 H1<br>H2<br>2<br>2<br>2<br>W2 W1<br>2<br>2<br>2<br>R2 R1 R2<br>2<br>2<br>Knockouts<br>2 H3<br>2 D2<br>2<br>2 D1<br>D3<br>2<br>2<br>2 Weight Knockouts at Inches (mm)<br>Voltage hp (IH) H1 H2 H3 D1 D2 D3 W1 W2 R1 Dia. R2 Dia. Lbs (kg) N1 (O.D.)<br>2 230V 20–30 24.8 (630) 24.2 (614) 23.2 (590) 10.1 (257) 3.0 (77) 7.3 (184) 9.3 (237) 7.5 (190) 0.7 (18) 0.4 (9) 77.2 (35) 3 at 1.5 (37)<br>480V 40–60<br>2 575V 30–40<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-186**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR8**
|||||H2<br>H1|||||
|---|---|---|---|---|---|---|---|---|
||||||||||
|W2<br>W1<br>R2<br>|||||||||
||||||||||
||||||||||
||||||||||
|**oltage**<br>**hp**<br>D1<br>R1|||||||||
|||||H3|||||
||1||||||||
||||||||||
||||||||||
||||||||||
||||||||||
||||||||||
|||**(IH)**<br>**D1**|**H1**|**H2**<br>**H3**<br>**W1**||**W2**<br>**R1 Dia.**<br>**R2 Dia.**<br>**Weight**<br>**Lbs (kg)**<br>(291)<br>10 (255)<br>0.7 (18)<br>0.4 (9)<br>127 (58)|||
|30V<br>40||–60<br>13.5 (344)<br>300.1 (764)<br>28.8 (732)<br>28.4 (721)<br>11.5<br>–125<br>–75|||||||
|80V<br>75|||||||||
|75V<br>50|||||||||
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-187**
Adjustable Frequency Drives
SPX9000 Drives
## 2.7
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, with Flange Kit, FR7 and FR8**
|<br>**W1**<br><br>H12<br>H13<br>H<br>W2<br>W4<br>D2<br>W6<br>W5|<br>|<br>|<br>|<br>|<br>|<br>||<br>|<br>||<br>|<br>**H5**<br>**H6**<br>H7<br>D1<br>H11<br>Dia. A<br>Dia. B<br>W7||**D2**<br>**Dia. A**<br>W3<br>W1|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
||H|||H||||H4|||H5|Dia|||
||W2<br>4||||||||||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
||||||||||||||||
|||||||||H1<br>H2|||||||
||||||||||||||||
||D2||||||||||||||
|||||||||||||H7|||
|||||||||||||D|||
||||||||||||||||
||||||||||||||||
||||||||||||||||
|||2|||||||||||**H7**<br>**D1**||
||||||||||||||||
||||||||||||||||
||H12|||H9||||H9|||H10||||
|||||||||||||Di|||
||W6<br>5|||||||**Flange Opening**<br>**FR7/FR8**|||||||
||H13|||||||H|||||||
||||||||||||||||
||||**W2**<br>**W3**||||**W4**|**H1**<br>||**H2**<br>|**H3**<br>**H4**||||
|**FR7**|||||||||||||||
|9.3 (237)<br>|||6.8 (175)<br>10.6 (270)<br>10.0 (253)<br>25.6 (652)<br>24.9 (632)<br>24.8 (630)<br>7.4 (189)|||||||||7.4 (189)<br>0.9 (23)|0.8 (20)<br>10.1 (257)<br>4.6 (117)<br>0.3 (6)||
|**FR8**|||||||||||||||
|11.2 (285)<br>|||—<br>14.0 (355)<br>13.0 (330)<br>32.8 (832)<br>—<br>29.3 (745)<br>10.2 (258)|||||||||10.4 (265)<br>1.7 (43)|2.2 (57)<br>13.5 (344)<br>4.3 (110)<br>0.4 (9)||
|**Flange O**<br>**W5**<br>|||**pening, FR7 and FR8**<br>**W6**<br>**W7**<br>**H8**<br>**H9**<br>**H10**<br>**H11**<br>**H12**|||||||||**H13**<br>**Dia. B**|||
|**FR7**|||||||||||||||
|9.2 (233)<br>|||6.9 (175)<br>10.0 (253)<br>24.4 (619)<br>7.4 (189)<br>7.4 (189)<br>1.4 (35)<br>1.3 (32)|||||||||1.0 (25)<br>0.3 (6)|||
|**FR8**|||||||||||||||
|11.9 (301)<br>|||—<br>13.0 (330)<br>31.9 (810)<br>10.2 (258)<br>10.4 (265)<br>—<br>—|||||||||1.3 (33)<br>0.4 (9)|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-188**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR9**
|D1<br>H6<br>W5<br><br>B- B+ /R+ R-<br>W5|H6<br>+ R-|||H4||H3|H3|||W4|W4|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||W3<br>PE||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
||||||H2<br>H1|||||||
|||||||||||||
|||||||||||||
|||||||||||||
||||||||||D|||
|**Voltage**<br>**hp (IH)**|||**W1**|**W2**|**W3**<br>**W4**<br>**H1**|||||||
|30V<br>75–100|||18.9<br>(480)<br>15.7<br>(400)||0.4<br>(9)<br>2.1<br>(54)<br>45.3<br>(1150)|||44.1<br>(1120)<br>0.6<br>(16)<br>7.4<br>(188)<br>14.2<br>(361.5)<br>13.4<br>(340)|||11.2<br>(285)<br>0.8<br>(21)<br>321.9 (146)|
|80V<br>150–200||||||||||||
|75V<br>100–175||||||||||||
**2**
_**Note**_
> 1 Brake resistor terminal box (H6) included when brake chopper ordered.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-189**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR9 with Flange Kit**
**2**
**==> picture [505 x 476] intentionally omitted <==**
**----- Start of picture text -----**<br>
H7<br>W5<br>W1<br>Dia.<br>D1<br>D2<br>D3<br>H4 H2 H4<br>H5 H3 H3 H3 H5<br>W4<br>W3 Flange Opening W2<br>FR9<br>W4<br>H6 H1<br>.20 (5)<br>Dia.<br>W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 H6 H7 D1 D2 D3 Dia.<br>20.9 (530) 20.0 (510) 19.1 (485) 7.9 (200) 0.2 (5.5) 51.7 (1312) 45.3 (1150) 16.5 (420) 3.9 (100) 1.4 (35) 0.4 (9) 0.1 (2) 24.9 (362) 13.4 (340) 4.3 (109) 0.8 (21)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-190**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21 and NEMA Type 12/IP54, FR10 Freestanding**
**==> picture [505 x 537] intentionally omitted <==**
**----- Start of picture text -----**<br>
W7 W5<br>W6 W6<br>W4 W4<br>Dia. 3<br>Dia. 1 Dia. 2<br>D3 D2 D6 D7<br>D5<br>D4<br>W2<br>W3 W3 W3 W3 W2<br>W1 D1<br>H1<br>H2<br>Operator<br>(Shown with<br>Optional<br>Disconnect)<br>H3<br>hp Weight<br>Volts (IH) W1 W2 W3 W4 W5 W6 W7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 Dia. 1 Dia. 2 Dia. 3 Lbs (kg)<br>480V 250–350 23.43 2.46 4.53 0.79 5.95 2.95 30.11 79.45 74.80 20.18 23.70 17.44 19.02 0.47 11.22 17.60 20.08 0.83 1.89 0.43 875 (389)<br>(595) (62.5) (115) (20) (151) (75) (79) (2018) (1900) (512.5) (602) (443) (483) (12) (285) (447) (510) (21) (48) (11)<br>690V 200–300<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-191**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
**FR10 Open Chassis**[1]
**2**
**==> picture [505 x 403] intentionally omitted <==**
**----- Start of picture text -----**<br>
H3<br>H5 H4<br>W3<br>W2 W5 W1<br>H7 H6 W4<br>H2<br>H1<br>D1<br>D2<br>D3 D4<br>Weight<br>Voltage hp (IH) W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 H6 H7 D1 D2 D3 D4 Lbs (kg)<br>480V 250–350 19.7 16.7 1.2 2.6 12.8 45.9 44.1 34.6 33.5 0.7 24.7 10.8 19.9 17.9 16.7 16.6 518<br>(500) (425) (30) (67) (325) (1165) (1121) (879) (850) (17) (627) (275) (506) (455) (423) (421) (235)<br>575V 200–300<br>**----- End of picture text -----**<br>
_**Note**_
> 1 SPX9000X FR12 is built of two FR10 modules. Please refer to SPX9000 installation manual for mounting instructions.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-192**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## **NEMA Type 1/IP21, FR11 Freestanding Drive**
**==> picture [505 x 527] intentionally omitted <==**
**----- Start of picture text -----**<br>
W5 W8<br>W6 W6 W6 W7 W7W6 W6 W6<br>W4<br>Dia. 3<br>Dia. 1 Dia. 2<br>D3 D5<br>D2 D4<br>W2<br>W3 W3 W3 W3 W2<br>W1 D1<br>H1<br>H2<br>Operator<br>(Shown with<br>Optional<br>Disconnect)<br>H3<br>hp Weight<br>Voltage (IH) W1 W2 W3 W4 W5 W6 W7 W8 H1 H2 H3 D1 D2 D3 D4 D5 Dia. 1 Dia. 2 Dia. 3 Lbs (kg)<br>480V 400–550 31.26 2.40 6.50 0.79 3.43 2.95 2.52 1.18 79.45 74.80 20.18 23.70 11.22 19.09 0.47 17.60 0.83 1.89 0.35 x 0.43 526<br>(794) (61) (165) (20) (87) (75) (64) (30) (2018) (1900) (512.5) (602) (285) (485) (12) (447) (21) (48) (9 x 11) (239)<br>690V 400–500<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-193**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## **FR11 Open Chassis**
**2**
**==> picture [376 x 527] intentionally omitted <==**
**----- Start of picture text -----**<br>
H2<br>W3 W3<br>W2 W2<br>W2 W2<br>Shown without<br>terminal cover<br>H1<br>W1<br>D2 D1<br>Weight<br>Voltage hp (IH) W1 W2 W3 H1 H2 D1 D2 Lbs (kg)<br>480V 400–550 27.9 (709) 8.6 (225) 2.6 (67) 45.5 (1155) 33.5 (850) 19.8 (503) 18.4 (468) 833 (378)<br>575V 400–500<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-194**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## **FR13, Open Chassis Inverter**
**==> picture [505 x 428] intentionally omitted <==**
**----- Start of picture text -----**<br>
W3<br>D6<br>Dia. 4<br>D8<br>D7<br>D5 [D6]<br>W4 W4 W4 W4 W4 Dia. 1<br>D1 D2 W1<br>H3 H1 H4<br>H2<br>Dia. 3<br>Dia. 2 W2 W2 W2 W2 D4 H5<br>D4<br>Dia. 3<br>D3<br>W5 W5 W5<br>Dia. Dia. Dia. Dia. Weight<br>W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 D1 D2 D3 D4 D5 D6 D7 D8 1 2 3 4 Lbs (kg)<br>27.87 5.91 26.65 4.57 3.35 41.54 2.46 39.86 41.34 0.79 21.77 0.51 0.63 1.97 1.06 1.57 5.91 9.64 0.35x0.59 0.18 0.51 0.37 683 (310)<br>(708) (150) (677) (116) (85) (1055) (62.5) (1012.5) (1050) (20) (553) (13) (16) (50) (27) (40) (150) (244.8) (9x15) (4.6) (13) (9.5)<br>**----- End of picture text -----**<br>
**2**
## _**Notes**_
9000X FR14 is built of two FR13 modules. Please refer to SPX9000 installation manual for mounting instructions.
FR13 is built from an inverter module and a converter module. Please refer to SPX9000 installation manual for mounting instructions.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-195**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
**FR13, Open Chassis Converter**
**2**
**==> picture [505 x 546] intentionally omitted <==**
**----- Start of picture text -----**<br>
W3 Dia. 3<br>D9<br>D8<br>D7<br>D6<br>Dia. 1 W4 W4 W4<br>D1 D2 W1<br>H3 H1 H4<br>H2<br>D4<br>W2 W2 D5 D5 H5<br>Dia. 2<br>Dia. 2<br>D3<br>W5 W5<br>Weight<br>W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 D1 D2 D3 D4 D5 D6 D7 D8 D9 Dia. 1 Dia. 2 Dia. 3 Lbs (kg)<br>18.74 5.91 17.52 4.57 3.35 41.54 2.46 39.86 41.34 0.69 14.69 0.51 0.73 6.42 2.56 1.06 1.57 5.91 5.24 0.35x0.59 0.51 0.37 295 (134)<br>(476) (150) (445) (116) (85) (1055) (62.5) (1012.5) (1050) (17.5) (373) (13) (18.5) (163) (65) (27) (40) (150) (133) (9x15) (13) (9.5)<br>Number of Input Units<br>480V Input 690V Input<br>Catalog Number hp Modules Catalog Number hp Modules<br>SPX800A0-4A2N1 800 2 SPX800A0-5A2N1 800 2<br>SPX900A0-5A2N1 900 2<br>SPXH10A0-5A2N1 1000 2<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-196**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
**FR13, Open Chassis Converter—900/1000 hp 480V**
**==> picture [505 x 450] intentionally omitted <==**
**----- Start of picture text -----**<br>
W3 Dia. 4<br>D9<br>D8<br>D7<br>D6<br>Dia. 1 W4 W4 W4 W4 W4<br>D1 D2 W1<br>H3 H1 H4<br>H2<br>D4<br>Dia. 2 W2 W2 W2 W2 D5 D5 H5<br>Dia. 3<br>D3<br>W5 W5 W5<br>Dia. Dia. Dia. Dia. Weight<br>W1 W2 W3 W4 W5 H1 H2 H3 H4 H5 D1 D2 D3 D4 D5 D6 D7 D8 D9 1 2 3 4 Lbs (kg)<br>27.87 5.91 26.65 4.57 3.35 41.54 2.46 39.86 41.34 0.69 14.69 0.51 0.73 6.42 2.56 1.06 1.57 5.91 5.24 0.35x0.59 0.18 0.51 0.37 443 (201)<br>(708) (150) (677) (116) (85) (1055) (62.5) (1012.5) (1050) (17.5) (373) (13) (18.5) (163) (65) (27) (40) (150) (133) (9x15) (4.6) (13) (9.5)<br>**----- End of picture text -----**<br>
**2**
## **Number of Input Units**
|**480V**<br>**Catalog Number**|**hp**|**Input**<br>**Modules**|
|---|---|---|
|**SPX900A0-4A2N1**<br>**SPXH10A0-4A2N1**|900<br>1000|3<br>3|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-197**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm)
## _**AC Choke Dimensions**_
**2**
## **Choke Types**
|**hoke Types**||||
|---|---|---|---|
|**atalog Number**<br>**Frame Size**|**Choke Type**1<br>CHK0400<br>CHK0520<br>CHK0520<br>2 x CHK0400<br>2 x CHK0400<br>2 x CHK0400<br>2 x CHK0520<br>2 x CHK0520<br>2 x CHK0520<br>2 x CHK0400<br>3 x CHK0520<br>3 x CHK0520<br>4 x CHK0520<br>6 x CHK0400|**Catalog Number**<br>**Frame Size**|**Choke Type**1|
|**oltage Range 380–500V**||**Voltage Range 525–690V**||
|**PX 250 4**<br>FR10<br>**PX 300 4**<br>**PX 350 4**||**SPX 200 5**<br>FR10<br>**SPX 250 5**<br>**SPX 300 5**|CHK0261|
||||CHK0400|
||||CHK0400|
|**PX 400 4**<br>FR11<br>**PX 500 4**<br>**PX 550 4**||**SPX 400 5**<br>FR11<br>**SPX 450 5**<br>**SPX 500 5**|CHK0520|
||||CHK0520|
||||2 x CHK0400|
|**PX 600 4**<br>FR12<br>**PX 650 4**<br>**PX 700 4**||**SPX 550 5**<br>FR12<br>**SPX 600 5**<br>**SPX 700 5**|2 x CHK0400|
||||2 x CHK0400|
||||2 x CHK0400|
|**PX 800 4**<br>FR13<br>**PX 900 4**<br>**PX H10 4**||**SPX 800 5**<br>FR13<br>**SPX 900 5**<br>**SPX H10 5**|2 x CHK0400|
||||2 x CHK0400|
||||2 x CHK0400|
|**PX H12 4**<br>FR14<br>**PX H16 4**||**SPX H13 5**<br>FR14<br>**SPX H15 5**|4 x CHK0400|
||||6 x CHK0400|
## **CHK0520**
**==> picture [343 x 275] intentionally omitted <==**
**----- Start of picture text -----**<br>
6.50 6.50<br>(165) (165) .24<br>(6)<br>8.03 (204)<br>1.69 19.57<br>(43) (497)<br>1 1 1<br>.79 17.57<br>(20) 15.71 (446)<br>1.58 (399)<br>3.03 (40)<br>(77) 3 3 3<br>.83<br>(21) .79<br>(20)<br>2 2 2<br>5.70 7.88<br>(145) (200)<br>9.61 (244) .55 (14)<br>Note<br>1 Chokes are provided with all FR10–FR14 drives.<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-198**
Adjustable Frequency Drives
2.7
SPX9000 Drives
Approximate Dimensions in Inches (mm) **CHK0400**
**2**
**==> picture [108 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
9.37 (238)<br>1.54<br>(39)<br>2.64<br>(67)<br>.75<br>(19)<br>5.51<br>(140)<br>10.30 (262)<br>**----- End of picture text -----**<br>
**==> picture [189 x 237] intentionally omitted <==**
**----- Start of picture text -----**<br>
.24<br>(6)<br>4.72 4.72<br>(120) (120)<br>13.79 (350)<br>1 1 1<br>.59<br>13.94(354) 1.18(15) 15.08(383) 16.58(421)<br>(30)<br>3 3 3<br>.59<br>(15) 2 2 2<br>5.90<br>(150)<br>10.83 (275)<br>**----- End of picture text -----**<br>
## **CHK0261**
**==> picture [117 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
.24<br>(6)<br>4.72 4.72<br>(120) (120)<br>13.79 (350)<br>**----- End of picture text -----**<br>
**==> picture [114 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
8.11 (206)<br>1.54<br>(39)<br>.87<br>(22)<br>4.25<br>.39 (108) .75 (19)<br>(10) Min.<br>9.06 (230)<br>**----- End of picture text -----**<br>
**==> picture [193 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 1 1<br>.59<br>(15)<br>14.06<br>1.18(30) 11.30 12.56(319) (357)<br>(287)<br>3 3 3<br>.59<br>(15) 2 2 2<br>5.90<br>(150)<br>10.83 (275)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-199**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
**2**
## **Enclosed Passive Filtered Drives**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|Enclosed Passive Filtered Drives||
|Application Description . . . . . . . . . . . . . . . . . .|**V6-T2-201**|
|Features and Benefits . . . . . . . . . . . . . . . . . . .|**V6-T2-207**|
|Standards and Certifications . . . . . . . . . . . . . .|**V6-T2-207**|
|Product Identification . . . . . . . . . . . . . . . . . . . .|**V6-T2-207**|
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V6-T2-208**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-209**|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-216**|
|Technical Data and Specifications . . . . . . . . . .|**V6-T2-221**|
|Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-223**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-224**|
|Enclosed 18-Pulse Drives . . . . . . . . . . . . . . . . . . .|**V6-T2-233**|
## **Enclosed Passive Filtered Drives**
## **Product Description**
The enclosed passive filtered clean power drives from Eaton’s Electrical Sector use tuned passive filters to significantly reduce line harmonics at the drive input terminals.
The enclosed passive filtered drive also delivers True Power Factor—in addition to reducing harmonic distortion, the enclosed passive filtered drive prevents transformer overheating and overloading of breakers and feeders, which enables the application of adjustable frequency drives on generators and other high impedance power systems.
The 9000X family of drives includes HVX9000, SVX9000, SLX9000, and SPX9000. 9000X Series drive ratings are rated for either high overload (IH) or low overload (IL). IL indicates 110% overload capacity for 1 minute out of 10 minutes. IH indicates 150% overload capacity for 1 minute out of 10 minutes.
## **Enclosed Passive Filtered Drive Products**
- **Standard Enclosed** —
covers a wide range of the most commonly ordered options. Pre-engineering eliminates the lead time normally associated with customer specific options. Available configurations are listed on **Pages V6-T2-207** to **V6-T2-222** .
- **Modified Standard**
**Enclosed** —applies to specific customer requirements that vary from the Standard Enclosed offering, such as the need for an additional indicating light or minor modifications to drawings. _Contact your local sales office for assistance in pricing and lead time._
> ● **Custom Engineered** —for those applications with more unique or complex requirements, these are individually engineered to the customer’s needs. _Contact your local sales office for assistance in pricing and lead time._
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-200**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Application Description**
Designed to meet the IEEE[®] drive is an excellent choice 519-1992 requirements for for small and midsize drives harmonic distortion, the applications where harmonics enclosed passive filtered are a concern.
## **What Are Harmonics?**
_**Take a perfect wave with a fundamental frequency of 60 Hz, which is close to what is supplied by the power company.**_
## **Perfect Wave**
**==> picture [178 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volts<br>(v)<br>Time<br>(t)<br>**----- End of picture text -----**<br>
**==> picture [75 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
f(x) = sin(x)<br>**----- End of picture text -----**<br>
_**Add a second wave that is five times the fundamental frequency— 300 Hz (typical of frequency added to the line by a fluorescent light).**_
## **Second Wave**
**==> picture [230 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volts<br>(v)<br>f(x) = [ sin(5x)]<br>5<br>Time<br>(t)<br>**----- End of picture text -----**<br>
_**Combine the two waves. The result is a 60 Hz supply rich in fifth harmonics.**_
## **Resulting Supply**
**==> picture [230 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volts<br>(v)<br> sin(5x)<br>f(x) = sin(x) +<br>5<br>Time<br>(t)<br>**----- End of picture text -----**<br>
## **What Causes Harmonics?**
## **Why Be Concerned About Harmonics?**
Harmonics are the result of nonlinear loads that convert AC line voltage to DC. Examples of equipment that are non-linear loads are listed below:
- nonlinear loads that convert 1. _**Installation and utility**_ AC line voltage to DC. _**costs increase.**_ Examples of equipment that Harmonics cause are non-linear loads are listed damage to transformers below: and lower efficiencies ● AC variable frequency due to the IR loss. drives These losses can
- ● DC drives become significant (from 16.6–21.6%) which can
- ● Fluorescence lighting, have a dramatic effect on computers, UPS systems the HVAC systems that
- ● Industrial washing are controlling the machines, punch presses, temperatures of the welders, etc. building where the transformer and drive
- _**How Can Harmonics Due to**_ equipment reside.
## _**How Can Harmonics Due to VFDs Be Diminished?**_
2. _**Downtime and loss of productivity.**_ Telephones and data transmissions links may not be guaranteed to work on the same power grids polluted with harmonics.
By applying drives from the Eaton Clean Power Drives Family; The HCX9000, enclosed passive filtered drive and enclosed 18-pulse drive.
## _**What Are Linear Loads?**_
3. _**Downtime and nuisance trips of drives and other equipment.**_ Emergency generators have up to three times the impedance that is found in a conventional utility source. Thus the harmonic voltage can be up to three times as large, causing risk of operation problems.
Linear loads are primarily devices that run across the line and do not add
harmonics. Motors are prime examples. The downside to having large motor linear loads is that they draw more energy than a VFD, because of their inability to control motor speed. In most applications there is a turn down valve used with the motor which will reduce the flow of the material, without significantly reducing the load to the motor. While this provides some measure of speed control, it is extremely inefficient.
4. _**Larger motors must be used.**_ Motors running across the line that are connected on polluted power distribution grids can overheat or operate at lower efficiency due to harmonics.
5. _**Higher installation costs.**_ Transformers and power equipment must be oversized to accommodate the loss of efficiencies. This is due to the harmonic currents circulating through the distribution without performing useful work.
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-201**
Adjustable Frequency Drives
Low Harmonic Drives
## 2.8
## **How Does a VFD Convert Three-Phase AC to a Variable Output Voltage and Frequency?**
**2** The six-pulse VFD: The majority of all conventional **2** drives that are built consist of a six-pulse configuration. The figure below represents a six- **2** diode rectifier design that converts three-phase utility **2** power to DC. The inverter section uses IGBTs to convert **2** DC power to a simulated AC sine wave that can vary in frequency from 0–400 Hz.
The six-pulse VFD drive creates harmonic current distortion. The harmonic current that is created is energy that can not be used by customers and causes external heat and losses to all components including other drives that are on the same power distribution. The figure is a 100 hp drive with 45A of damaging harmonic current.
## **100 hp Six-Diode Rectifier Design**
**==> picture [233 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current<br>Amps<br>1000<br>500<br>0<br>–500<br>–1000<br>0.100 0.10625 0.1125 0.11875 0.125<br>Time in Seconds<br>**----- End of picture text -----**<br>
## **Guidelines of Meeting IEEE Std. 519-1992 Harmonic Distortion Limits**
The IEEE 519-1992 users that are implementing Specification is a standard medium and low voltage that provides guidelines for equipment. commercial and industrial
## **Maximum Harmonic Current Distortion in % of the Fundamental (120V through 69,000V)**
||**Harmonic**|**Order**|**(Odd**|**Harmonics)**|**Harmonics)**||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Isc/IL**|**h<11**|**11<**<br>~~**h**~~**<17**||**17<**<br>~~**h**~~**<23**||**23<**<br>~~**h**~~**<35**||**35<**<br>~~**h**~~||**TDD**|
|<20|4.0|2.0||1.5||0.6||0.3||5.0|
|20<50|7.0|3.5||2.5||1.0||0.5||8.0|
|50<100|10.0|4.5||4.0||1.5||0.7||12.0|
|100<1000|12.0|5.5||5.0||2.0||1.0||15.0|
|>1000|15.0|7.0||6.0||2.5||1.4||20.0|
_**The ratio Isc/IL is the ratio of the short-circuit current available at the point of common coupling (PCC), to the maximum fundamental load current. Consequently, as the size of the user load decreases with respect to the size of the system, the percentage of harmonic current that the user is allowed to inject into the utility system increases.**_
## _**Notes**_
TDD = Total demand distortion is the harmonic current distortion in percent of the maximum demand load current (15 or 30 minute demand).
ISC = Maximum short-circuit current at the PCC not counting motor contribution.
IL = Maximum demand load current for all of the connected loads (fundamental frequency component) at the PCC. All of the limits are measured at a point of common coupling.
## **100 hp Six-Pulse Nonproductive Harmonic Current**
**==> picture [233 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current<br>Amps<br>1000<br>500<br>0<br>–500<br>–1000<br>0.100 0.10625 0.1125 0.11875 0.125<br>Time in Seconds<br>**----- End of picture text -----**<br>
## **Six-Pulse Nonproductive Harmonic Current**
## **Six-Pulse Circuit**
|Current harmonics|||
|---|---|---|
|I1= 100%|I11= 6.10%|I19= 1.77%|
|I5= 22.5%<br>I7= 9.38%|I13= 4.06%<br>I17= 2.26%|I23= 1.12%<br>I25= 0.86%|
|Power = 100 hp|||
|Harmonic current = 45 amps|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-202**
**==> picture [540 x 475] intentionally omitted <==**
**----- Start of picture text -----**<br>
Adjustable Frequency Drives 2.8<br>Low Harmonic Drives<br>One-Line Diagram for Harmonic Analysis<br>2<br>2<br>____Volts ____Volts ____Volts ____Volts Source A<br>PCC 2<br>Utility Side<br>AC AC 2<br>Motor Motor<br>2<br>2<br>TransformerUtility Side TransformerCustomer 2<br>____Volts ____kVA ____Volts ____kVA MotorAC MotorAC 2<br>____Isc ____Isc<br>____Impedance ____Impedance 2<br>2<br>Customer AC AC<br>Generator Motor Motor 2<br>____Volts Generator<br>: t ____kVA Set tt 2<br>____Isc<br>____Impedance<br>2<br>Total Linear Motor Loads ____AMPS<br>Source B Total Non-Linear Drive Loads ____AMPS<br>2<br>The best way to estimate AFD harmonic contribution to an electrical system is to perform a harmonic analysis based on known system<br>characteristics. The one line in this figure would provide the data to complete the calculations. 2<br>Terms Harmonic Reduction Line Reactor 2<br>● PCC (Point of Common Methods to Meet IEEE 519<br>Coupling) is defined as the 2<br>electrical connecting point 1. Line Reactor<br>between the utility and A line reactor is a three-phase AFD Motor 2<br>multiple customers per the series inductance on the line<br>specifications in IEEE 519 side of an AFD. If a line<br>● S t EC) 2<br>**----- End of picture text -----**<br>
A line reactor is a three-phase series inductance on the line side of an AFD. If a line reactor is applied on all AFDs, it is possible to meet IEEE guidelines where 10–25% of system loads are AFDs, depending on the stiffness of the line and the value of line reactance. Line reactors are available in various values of percent impedance, most typically 1–1.5%, 3% and 5%.
- POA (Point of Analysis) is defined as where the harmonic calculations are taken
## _**Advantages**_
## _**Disadvantages**_
- Low cost
- May not reduce harmonic levels to below IEEE 5191992 guidelines
- Can provide moderate reduction in voltage and current harmonics
An oscilloscope can make all measurements at the PCC or POA to do an on-site harmonic evaluation.
- Voltage drop due to IR loss
- Available in various values of percent impedance
- Provides increased input protection for AFD and its semiconductors from line transients
**Note:** The 9000X drives come standard with a nominal 3% input impedance.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-203**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## _**2. Passive Filters**_
**2**
Tuned harmonic filters a specific range of involve the series connection frequencies. This path of an inductor with the shunt presents an alternative to the connection of an inductor and flow of harmonic currents capacitor to form a low back into the utility source. impedance path to ground for
## **Enclosed Drive with Integrated Passive Filter**
**==> picture [455 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tuned<br>Harmonic<br>Capacitor<br>6-Pulse Diode Inverter Section<br>Shunt Bridge Rectifier<br>Fusing Converter Section<br>(+) DC<br>Tuned<br>Shunt<br>Reactor<br>L1A<br>1<br>L2A AC<br>2<br>Motor<br>L3A<br>3<br>AC Input<br>Reactor<br>(–) DC<br>Dynamic Braking Output Transistors<br>Three-Phase Transistor IGBT Section<br>Input Bus<br>Capacitors<br>**----- End of picture text -----**<br>
**100 hp Enclosed 480V Drive with Integrated Passive Filter**
**==> picture [231 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current<br>Amps<br>200<br>100<br>0<br>–100<br>–200<br>Time<br>**----- End of picture text -----**<br>
## **100 hp Enclosed 480V Drive with Integrated Passive Filter**
## **Passive Filter**
|**Passive Filter**|||
|---|---|---|
|Current harmonics|||
|I1= 100%|I11= 0.24%|I19= 0.50%|
|I5= 3.76%<br>I7= 1.65%|I13= 1.1%<br>I17= 0.80%|I23= 0.55%<br>I25= 0.80%|
|Power = 100 hp|||
|Hc= 8.6 Amps|||
## _**Advantages**_
## _**Disadvantages**_
- Capacitors age over time, unlike magnetics
- Low cost for smaller horsepower applications
- More effective harmonic ● Not as effective as attenuation than 12-pulse 18-pulse drives drives ●
- Challenging to retrofit with
- ● Provides increased input bypass applications protection for AFD from line transients
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-204**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## _**3. 12-Pulse Converters**_
A 12-pulse converter incorporates two separate AFD input semiconductor bridges, which are fed from 30º phase shifted power sources with identical impedance. The sources may be two isolation transformers, where one is a delta/wye design (which provides the phase shift) and
the second a delta/delta design (which does not phase shift). The 12-pulse arrangement allows the harmonics from the first converter to cancel the harmonics of the second. Up to approximately 85% reduction of harmonic current and voltage distortion may be achieved (over standard
six-pulse converter). This permits a facility to use a larger percentage of AFD loads under IEEE 519-1992 guidelines than allowable using line reactors or DC chokes. A harmonic analysis is required to guarantee compliance with guidelines.
**2**
## **Basic 12-Pulse Rectifier with “Phase Shifting” Transformer**
**==> picture [431 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
12-Pulse 12-Pulse Diode Inverter Section<br>Phase-Shifting Bridge Rectifier<br>Transformer Converter Section<br>(+) DC<br>L1A<br>L2A<br>L3A<br>AC<br>Motor<br>L1B<br>L2B<br>L3B<br>(-) DC<br>12-Pulse Diode Dynamic Braking Output Transistors<br>Bridge Rectifier Transistor IGBT Section<br>Converter Section Bus<br>Capacitors<br>**----- End of picture text -----**<br>
## **100 hp 480V Drive with 12-Pulse Rectifier**
**==> picture [231 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current<br>Amps<br>200<br>100<br>0<br>–100<br>–200<br>Time<br>**----- End of picture text -----**<br>
## **100 hp 480V Drive with 12-Pulse Rectifier**
## **12-Pulse Circuit**
|**12-Pulse Circuit**|||
|---|---|---|
|Current harmonics|||
|I1= 100%<br>I5= 1.25%|I11= 4.19%<br>I13= 2.95%|I19= 0.06%<br>I23= 0.87%|
|I7= 0.48%|I17= 0.21%|I25= 0.73%|
|Power = 100 hp|||
|Hc= 20 Amps|||
## _**Advantages Disadvantages**_
- Reasonable cost, although ● Impedance matching of significantly more than phase shifted sources is reactors or chokes critical to performance
- Substantial reduction (up to ● Transformers often require approx. 85%) in voltage separate mounting or and current harmonics larger AFD enclosures
- Provides increased input ● May not reduce protection for AFD and its distribution harmonic levels semiconductors from line to below IEEE 519-1992 transients guidelines
- Cannot retrofit for most AFDs
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-205**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## _**4. Clean Power Drives**_
When the total load is comprised of non-linear load **2** such as drives, and the ratio is lsc/IL, the greatest **2** harmonic mitigation is required. Under these **2** conditions, the currents drawn from the supply need **2** to be sinusoidal and “clean” such that system interference and additional
losses are negligible. Eaton’s Enclosed 18-Pulse clean power drive uses a phaseshifting auto-transformer with delta-connected winding that carries only the ampere-turns caused by the difference in load currents. This results in nine separate phases. In this type of configuration, the
total kVA rating of the transformer magnetic system was only 48% that of the motor load. A traditional isolated transformer system, with multipulse windings, would require the full kVA rating to be supported, which is more common in an MV step-down transformer.
The integrated 18-pulse clean power drive, with near sine wave input current and low harmonics will meet the requirements of IEEE 5191992 under all practical operating conditions. The comparisons with six-pulse passive filter and 12-pulse systems are shown on **Pages V6-T2-202** , **V6-T2-204** and below.
**Basic 18-Pulse Rectifier with Phase-Shifting Auto-Transformer**
**==> picture [482 x 191] intentionally omitted <==**
**----- Start of picture text -----**<br>
18-Pulse SCR Inverter Section<br>Bridge Rectifier Pre-charge<br>Converter Section Circuit<br>(+) DC<br>A 1<br>2<br>1 3<br>9 2<br>1 8 3 4 AC<br>2 N 5 Motor<br>3 7 4 6<br>C 7<br>6 5 8<br>9<br>(–) DC<br>18-Pulse Diode Rectifiers Dynamic Braking Output Transistors<br>Phase-Shifting Transistor IGBT Section<br>3-Phase Auto-Transformer<br>Bus<br>AC Input<br>Capacitors<br>**----- End of picture text -----**<br>
## **100 hp 480V Drive with 18-Pulse Rectifiers**
**==> picture [231 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current<br>Amps<br>200<br>100<br>0<br>–100<br>–200<br>Time<br>**----- End of picture text -----**<br>
## **100 hp 480V Drive with 18-Pulse Rectifiers**
## **18-Pulse Clean Power**
|Current harmonics|||
|---|---|---|
|I1= 100%|I11= 0.24%|I19= 1.00%|
|I5= 0.16%<br>I7= 0.03%|I13= 0.10%<br>I17= 0.86%|I23= 0.01%<br>I25= 0.01%|
|Power = 100 hp|||
|Hc= 5.9 Amps|||
## _**Advantages Disadvantages**_
- Effectively guarantees ● Not as cost effective as compliance with IEEE 519some other methods at 1992 small (<50) horsepower
- Provides increased input protection for AFD and its semiconductors from line transients
- Up to 4 times the harmonic reduction of 12-pulse methods
- Smaller transformer than isolation transformer used in 12-pulse converter
- Minimizes ripple current in capacitors, doubling expected capacitor life
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-206**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Features and Benefits**
New enclosed passive filtered clean power drive features include (at 480V):
- UL Type 1, UL Type 12, UL Type 3R and NEMA 12 with gaskets and filters
- Input voltage: 480V, 230V, 575V
- Horsepower range:
- 480V, 7-1/2–400 hp IL
- 230V, 7-1/2–100 hp IL; consult factory for details
- 575V, 15–400 hp IL; consult factory for details
- Single enclosure for both drive and filter reduces field wiring and enables convenient bypass installation
- Packaged solution ensures optimal coordination of drive and filter
## **Standards and Certifications**
- UL
- cUL
- 508C
**2**
- Complete range of control, network and power options
## **Product Identification**
## **Enclosed Passive Filtered Drive—UL Type 12, 40 hp**
**==> picture [412 x 248] intentionally omitted <==**
**----- Start of picture text -----**<br>
SVX9000 Drive<br>Input Reactor<br>Optional Breaker<br>Disconnect (P1)<br>Zi? | | eo" | = l y<br>a \| le il<br>Shunt Fusing<br>Door Mounted<br>’ Suse) f:<br>Keypad<br>Tuned Shunt<br>Reactor<br>N Ho & 7 2 ‘1,<br>Tuned Harmonic<br>Capacitor<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-207**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Catalog Number Selection**
## **Enclosed Passive Filtered Drives**
**2**
Build Alphabetically and Numerically
**CFX 050 1 4 A A**
~~**_ _ _ _ _ _ _ _ _ _**~~
||||||||||||||||||~~**_**~~|~~**_ _ _ _**~~|~~**_ _ _ _**~~|~~**_ _ _ _**~~|~~**_ _ _ _**~~|~~**_ _ _ _ _**~~|~~**_ _ _ _ _**~~|~~**_ _ _ _ _**~~|~~**_ _ _ _ _**~~|~~**_ _ _ _ _**~~|~~**_ _ _ _ _**~~|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||**Product F**~~**a**~~|~~**mil**~~|||||||||||||||**Enclosed Options**234|||||||||**Type**|
||||~~**y**~~|||||||||||||||||||||||||
|**CFX**= Inte|grate|d filter clean power drive||||||||||||||||**K1**<br>**K2**<br>**K3**<br>**K4**<br>**K5**<br>**K6**<br>**KF**<br>**KO**|Door-mounted speed potentiometer5<br>Door-mounted speed potentiometer with HOA selector<br>switch5<br>3–15 psig follower<br>HAND/OFF/AUTO switch (22 mm)<br>MANUAL/AUTO reference switch (22 mm)<br>START/STOP pushbuttons (22 mm)<br>Bypass test switch for RA and RB<br>Standard elapsed time meter||||||||Control<br>Control<br>Control<br>Control<br>Control<br>Control<br>Addl. bypass<br>Control|
|||||||||||||||||||||||||||||
||**H**|**orsepower Rating**||||||||||||||||||||||||||
|||||||||||||||||||||||||||||
|**007**= 7-1/<br>**010**= 10 h<br>**015**= 15 h<br>**020**= 20 h<br>**025**= 25 h<br>**030**= 30 h|2 hp<br>p<br>p<br>p<br>p<br>p|**040**= 40 hp<br>**050**= 50 hp<br>**060**= 60 hp<br>**075**= 75 hp<br>**100**= 100 hp<br>**125**= 125 hp||**15**<br>**20**<br>**25**<br>**30**<br>**35**<br>**40**|**0**= 150 hp<br>**0**= 200 hp<br>**0**= 250 hp<br>**0**= 300 hp<br>**0**= 350 hp<br>**0**= 400 hp|||||||||||||||||||||||
|||||||||||||||||||**L1**<br>**L2**<br>**LE**|Power, RUN and fault pilot lights<br>Bypass pilot lights for RA, RB, bypass options<br>Red RUN light||||||||Light<br>Addl. bypass<br>Light|
|||||||||||||||||||||||||||||
|||||||||||||||||||**P1**<br>**P3**<br>**P7**<br>**P8**<br>**PE**<br>**PF**<br>**PG**<br>**PH**<br>**PI**<br>**PN**|Input circuit breaker<br>Input line fuses (200 kAIC)<br>Input power surge protection<br>TVSS surge protective device<br>Output contactor<br>Output filter<br>MotoRx (up to 600 ft) 1000 V/μS DV/DT filter<br>Single overload relay<br>Dual overload relays<br>Dual overloads for bypass||||||||Input<br>Input<br>Input<br>Input<br>Output<br>Output<br>Output<br>Output<br>Output<br>Addl. bypass|
|||**Enclosure Ratin**||||||||||||||||||||||||||
|||||||||~~**g**~~||||||||||||||||||||
|||**1**= UL Type 1<br>**2**= UL Type 12<br>**3**= UL Type 3R<br>**6**= NEMA 12 filtered||||||||||||||||||||||||||
|||||||||||||||||||||||||||||
|||**Voltage R**||||~~**ating**~~||||||||||||||||||||||
|||||||||||||||||||||||||||||
|||**1**= 208V<br>**2**= 230V<br>**4**= 480V<br>**5**= 575V (575–600V)||||||||||||||||||||||||||
|||||||||||||||||||**RA**<br>**RB**<br>**RC**<br>**RD**<br>**RG**|Manual HOA bypass controller<br>Manual IOB bypass controller<br>Auto transfer HOA bypass controller<br>Auto transfer IOB bypass controller<br>Reduced voltage starter for bypass||||||||Bypass<br>Bypass<br>Bypass<br>Bypass<br>Bypass|
|||||||||||||||||||||||||||||
|||**Application—Torque/B**|||||~~**raking**1~~|||||||||||**S4**<br>**S5**<br>**S6**<br>**S9**|Floor stand 6 in<br>Floor stand 22 in<br>Floor stand 12 in<br>Space heater||||||||Enclosure<br>Enclosure<br>Enclosure<br>Enclosure|
||**A**=<br>**B**=<br>**D**=<br>**E**=|IL/no brake chopper<br>IL/internal brake chopper<br>IH/no brake chopper<br>IH/internal brake chopper||||||||||||||||||||||||||
|||||||||||||||||||||||||||||
||||||||~~**le**~~||||||||||||||**Communication Options**6|||||||
|||**Enclosed St**|||||~~**le**~~|||||||||||**C2**<br>= Modbus<br>**C3**<br>= PROFIBUS DP<br>**C4**<br>= LonWorks<br>**C5**<br>= PROFIBUS DP (D9 Connector)<br>**C6**<br>= CANopen (Slave)<br>**C7**<br>= DeviceNet|||||||**C8** = Modbus (D9 type connector)<br>**CA** = Johnson Controls N2<br>**CI**<br>= Modbus TCP<br>**CJ** = BACnet<br>**CQ** = EtherNet/IP<br>**D3** = RS-232 with D9 connection|||
|||||||||||||||||||||||||||||
|||**A**= Enclosed drive||||||||||||||||||||||||||
|||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||
|||||||||||||||||||||||||||||
|||||||||||**Control Options**||||||||||||||||||
|||||||||||||||||||||||||||||
|||||||||||**B1**= 6 DI, 1 ext +24 Vdc/EXT +24 Vdc<br>**B2**= 1 RO (NC-NO), 1 RO (NO), 1 therm<br>**B4**= 1 AI (mA isolated), 2 AO (mA isolated), 1 ext<br>**B5**= 3 RO (NO)<br>**B8**= 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>**B9**= 1 RO (NO), 5 DI 42–240 Vac input||||||||||+24 Vdc/EXT +24 Vdc||||**HT**<br>**VB**||High temperature rating for 50°C7<br>Varnished boards||
|||||||||||||||||||||||||||||
## _**Notes**_
- 1 Brake chopper is standard in 208V, 230V and 480V drives up to FR6; optional in all other drives.
- 2 Local/remote keypad is included as the standard control panel.
- 3 Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
- 4 See **Pages V6-T2-218** and **V6-T2-219** for complete descriptions.
- 5 Includes local/remote speed reference switch.
- 6 See **Pages V6-T2-216** and **V6-T2-217** for complete descriptions.
- 7 Consult Eaton for availability.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-208**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Product Selection**
## _**When Ordering**_
- Select a base catalog number that meets the application requirements— nominal horsepower, voltage and enclosure rating. (The enclosed drive’s continuous output amp rating should be equal to or greater than the motor’s full load amp rating.) The base enclosed package includes a standard drive, doormounted alphanumeric panel and enclosure.
> ● The enclosed passive filtered drive product uses the term High Overload (IH) in place of the term Constant Torque (CT). Likewise, Low Overload (IL) is used in place of the term Variable Torque (VT). The new terms are a more precise description of the rating. The older terms included ambient temperature ratings in addition to overload ratings. In order to minimize enclosure size and offer the highest ambient temperature rating, overload and temperature ratings are now treated separately. Ambient temperature ratings are shown in the following table.
## **Ambient Temperature Ratings**
|**Enclosure**|||
|---|---|---|
|**Size**|**IH**|**IL**|
|B, C, 91|40°C|40°C|
|7, 8|50°C|50°C|
- If dynamic brake chopper or control/communication option is desired, change the appropriate code in the base catalog number.
- All of the programming is exactly the same as the standard SVX9000 drive.
- Select enclosed options. Add the codes as suffixes to the base catalog number in alphabetical and numeric order.
## _**Note**_
- 1 For high temperature rating, select HT option code and contact factory.
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-209**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
**2** ~~oo~~
## **208V Drives**
**Enclosed Passive Filtered Drive**
## **UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered**
**==> picture [413 x 311] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|NEC|Chassis|UL Type 1|UL Type 12 and NEMA 12 Filtered|UL Type 3R|
|hp|Current (A)|Frame|Base Catalog Number|Base Catalog Number|Base Catalog Number|
|Low Overload Drive|
|7-1/2|24.2|FR5|1|CFX00721BA|CFX00731BA|
|10|30.8|FR5|1|CFX01021BA|CFX01031BA|
|15|46.2|FR6|1|CFX01521BA|CFX01531BA|
|20|59.4|FR6|1|CFX02021BA|CFX02031BA|
|25|74.8|FR7|1|CFX02521AA|CFX02531AA|
|30|88|FR7|1|CFX03021AA|CFX03031AA|
|40|114|FR7|1|CFX04021AA|CFX04031AA|
|50|143|FR8|CFX05011AA|CFX05061AA|CFX05031AA|
|60|169|FR8|CFX06011AA|CFX06061AA|CFX06031AA|
|75|211|FR8|CFX07511AA|CFX07561AA|CFX07531AA|
|100|273|FR9|CFX10011AA|CFX10061AA|CFX10031AA|
|High Overload Drive|
|7-1/2|24.2|FR5|1|CFX00721EA|CFX00731EA|
|10|30.8|FR6|1|CFX01021EA|CFX01031EA|
|15|46.2|FR6|1|CFX01521EA|CFX01531EA|
|20|59.4|FR7|1|CFX02021DA|CFX02031DA|
|25|74.8|FR7|1|CFX02521DA|CFX02531DA|
|30|88|FR7|1|CFX03021DA|CFX03031DA|
|40|114|FR8|CFX04011DA|CFX04061DA|CFX04031DA|
|50|143|FR8|CFX05011DA|CFX05061DA|CFX05031DA|
|60|169|FR8|CFX06011DA|CFX06061DA|CFX06031DA|
|75|211|FR9|CFX07511DA|CFX07561DA|CFX07531DA|
|100|273|FR9|CFX10011DA|CFX10061DA|CFX10031DA|
**----- End of picture text -----**<br>
## **Enclosed Passive Filtered Drive Enclosure**
**==> picture [430 x 91] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||
|---|---|---|---|---|---|---|
|Chassis|UL Type 1|UL Type 12|UL Type 3R|
|Frame|Disconnect Only|With Power Options|Disconnect Only|With Power Options|Disconnect Only|With Power Options|
|FR4|N/A|N/A|B|C|B|C|
|FR5|N/A|N/A|B|C|B|C|
|FR6|N/A|N/A|B|C|B|C|
|FR7|N/A|7|C|7|C|D|
|FR8|7|7|7|7|F|F|
|FR9|8|8|8|8|F|F|
**----- End of picture text -----**<br>
## **Enclosure Dimension Drawings**
**==> picture [170 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Enclosure|
|Size|UL Type 1 and UL Type 12|UL Type 3R|
|B|See|Page V6-T2-224|See|Page V6-T2-226|
|C|See|Page V6-T2-225|See|Page V6-T2-227|
|D|N/A|See|Page V6-T2-228|
|F|N/A|See|Page V6-T2-229|
|7|[2]|See|Page V6-T2-230|3|
|8|[2]|See|Page V6-T2-231|3|
|9|See|Page V6-T2-232|3|
**----- End of picture text -----**<br>
## _**Notes**_
1 FR5–FR7 drives not available in UL Type 1.
2 Enclosures 7 and 8 are NEMA 12 filtered.
3 Not available for UL Type 3R.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-210**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **230V Drives**
## **UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered**
|**Enclosed Passive**<br>**Filtered Drive**|**UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered**|**UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered**<br>**NEC**|**UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered**<br>**Chassis**|**UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered**<br>**Chassis**<br>**UL Type 1**|**UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered**<br>**UL Type 12 and NEMA 12 Filtered**|**UL Type 3R**|
|---|---|---|---|---|---|---|
||**hp**<br>**Current (A)**<br>**Low Overload Drive**||**Frame**|**Base Catalog Number**|**Base Catalog Number**|**Base Catalog Number**|
||7-1/2|22|FR5|1|**CFX00722BA**|**CFX00732BA**|
||10|28|FR5|1|**CFX01022BA**|**CFX01032BA**|
||15|42|FR6|1|**CFX01522BA**|**CFX01532BA**|
||20|54|FR6|1|**CFX02022BA**|**CFX02032BA**|
||25|68|FR7|1|**CFX02522AA**|**CFX02532AA**|
||30<br>40|80<br>104|FR7<br>FR7|1<br>1|**CFX03022AA**<br>**CFX04022AA**|**CFX03032AA**<br>**CFX04032AA**|
||50|130|FR8|**CFX05012AA**|**CFX05062AA**|**CFX05032AA**|
||60|154|FR8|**CFX06012AA**|**CFX06062AA**|**CFX06032AA**|
||75|192|FR8|**CFX07512AA**|**CFX07562AA**|**CFX07532AA**|
||100|248|FR9|**CFX10012AA**|**CFX10062AA**|**CFX10032AA**|
||**High Overload Drive**||||||
||7-1/2<br>10|22<br>28|FR5<br>FR6|1<br>1|**CFX00722EA**<br>**CFX01022EA**|**CFX00732EA**<br>**CFX01032EA**|
||15<br>20|42<br>54|FR6<br>FR7|1<br>1|**CFX01522EA**<br>**CFX02022DA**|**CFX01532EA**<br>**CFX02032DA**|
||25|68|FR7|1|**CFX02522DA**|**CFX02532DA**|
||30|80|FR7|1|**CFX03022DA**|**CFX03032DA**|
||40|104|FR8|**CFX04012DA**|**CFX04062DA**|**CFX04032DA**|
||50|130|FR8|**CFX05012DA**|**CFX05062DA**|**CFX05032DA**|
||60|154|FR8|**CFX06012DA**|**CFX06062DA**|**CFX06032DA**|
||75<br>100|192<br>248|FR9<br>FR9|**CFX07512DA**<br>**CFX10012DA**|**CFX07562DA**<br>**CFX10062DA**|**CFX07532DA**<br>**CFX10032DA**|
**2**
## **Enclosed Passive Filtered Drive Enclosure**
|**Chassis**|**UL Type 1**||**UL Type 12**||**UL Type 3R**||
|---|---|---|---|---|---|---|
|**Frame**<br>FR4|**Disconnect Only**<br>N/A|**With Power Options**<br>N/A|**Disconnect Only**<br>B|**With Power Options**<br>C|**Disconnect Only**<br>B|**With Power Options**<br>C|
|FR5<br>FR6|N/A<br>N/A|N/A<br>N/A|B<br>B|C<br>C|B<br>B|C<br>C|
|FR7|N/A|7|C|7|C|D|
|FR8|7|7|7|7|F|F|
|FR9|8|8|8|8|F|F|
## **Enclosure Dimension Drawings**
|**Enclosure**|||
|---|---|---|
|**Size**|**UL Type 1 and UL Type 12**|**UL Type 3R**|
|**B**<br>**C**|See**Page V6-T2-224**<br>See**Page V6-T2-225**|See**Page V6-T2-226**<br>See**Page V6-T2-227**|
|**D**<br>**F**|N/A<br>N/A|See**Page V6-T2-228**<br>See**Page V6-T2-229**|
|**7**2|See**Page V6-T2-230**|3|
|**8**2|See**Page V6-T2-231**|3|
|**9**|See**Page V6-T2-232**|3|
## _**Notes**_
1 FR5–FR7 drives not available in UL Type 1.
2 Enclosures 7 and 8 are NEMA 12 filtered.
- 3 Not available for UL Type 3R.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-211**
2.8
**2** ~~7~~
## Adjustable Frequency Drives
## Low Harmonic Drives
## **480V Drives**
**Enclosed Passive Filtered Drive**
## **Enclosed Passive Filtered Base Drive**
**==> picture [417 x 469] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|NEC|Chassis|UL Type 1|UL Type 12 and NEMA 12 Filtered|UL Type 3R|
|hp|Current (A)|Frame|Base Catalog Number|[1]|Base Catalog Number|[1]|Base Catalog Number|[1]|
|Low Overload Drive|
|7-1/2|11|FR4|2|CFX00724BA|CFX00734BA|
|10|14|FR5|2|CFX01024BA|CFX01034BA|
|15|21|FR5|2|CFX01524BA|CFX01534BA|
|20|27|FR5|2|CFX02024BA|CFX02034BA|
|25|34|FR6|2|CFX02524BA|CFX02534BA|
|30|40|FR6|2|CFX03024BA|CFX03034BA|
|40|52|FR6|2|CFX04024BA|CFX04034BA|
|50|65|FR7|CFX05014AA|[3]|CFX05024AA|CFX05034AA|
|60|77|FR7|CFX06014AA|[3]|CFX06024AA|CFX06034AA|
|75|96|FR7|CFX07514AA|[3]|CFX07524AA|CFX07534AA|
|100|124|FR8|CFX10014AA|CFX10064AA|CFX10034AA|
|125|156|FR8|CFX12514AA|CFX12564AA|CFX12534AA|
|150|180|FR8|CFX15014AA|CFX15064AA|CFX15034AA|
|200|240|FR9|CFX20014AA|CFX20064AA|CFX20034AA|
|250|302|FR9|CFX25014AA|CFX25064AA|CFX25034AA|
|300|361|FR10|CFX30014AA|CFX30064AA|4|
|350|414|FR10|CFX35014AA|CFX35064AA|4|
|400|477|FR10|CFX40014AA|CFX40064AA|4|
|High Overload Drive|
|7-1/2|11|FR5|2|CFX00724EA|CFX00734EA|
|10|14|FR5|2|CFX01024EA|CFX01034EA|
|15|21|FR5|2|CFX01524EA|CFX01534EA|
|20|27|FR6|2|CFX02024EA|CFX02034EA|
|25|34|FR6|2|CFX02524EA|CFX02534EA|
|30|40|FR6|2|CFX03024EA|CFX03034EA|
|40|52|FR7|CFX04014DA|[3]|CFX04024DA|CFX04034DA|
|50|65|FR7|CFX05014DA|[3]|CFX05024DA|CFX05034DA|
|60|77|FR7|CFX06014DA|[3]|CFX06024DA|CFX06034DA|
|75|96|FR8|CFX07514DA|CFX07564DA|CFX07534DA|
|100|124|FR8|CFX10014DA|CFX10064DA|CFX10034DA|
|125|156|FR8|CFX12514DA|CFX12564DA|CFX12534DA|
|150|180|FR9|CFX15014DA|CFX15064DA|CFX15034DA|
|200|240|FR9|CFX20014DA|CFX20064DA|CFX20034DA|
|250|302|FR10|CFX25014DA|CFX25064DA|4|
|300|361|FR10|CFX30014DA|CFX30064DA|4|
|350|414|FR10|CFX35014DA|CFX35064DA|4|
**----- End of picture text -----**<br>
## _**Notes**_
1 The integrated filter clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
2 FR4–FR6 drives not available in UL Type 1.
- 3 This catalog number is used only with power options.
- 4 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-212**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Enclosed Passive Filtered Drive Enclosure**
|**Enclosed Passive Filtered Drive Enclosure**||
|---|---|
|**Chassis**<br>**Frame**<br>**UL Type 1**<br>**Disconnect Only**<br>**With Power Options**<br>FR4<br>N/A<br>N/A<br>FR5<br>N/A<br>N/A<br>FR6<br>N/A<br>N/A<br>FR7<br>N/A<br>7<br>FR8<br>7<br>7<br>FR9<br>8<br>8<br>FR10<br>9<br>9|**UL Type 12**<br>**Disconnect Only**<br>**With Power Options**|
||B<br>C|
||B<br>C|
||B<br>C|
||C<br>7|
||7<br>7|
||8<br>8|
||9<br>9|
|**UL Type 3R**<br>**Disconnect Only**<br>**With Power Options**<br>B<br>C<br>B<br>C<br>B<br>C<br>C<br>D<br>F<br>F<br>F<br>F<br>1<br>1|**2**|
|---|---|
||**2**|
||**2**<br>**2**<br>**2**<br>**2**|
## **Enclosure Dimension Drawings**
|**Enclosure**|||
|---|---|---|
|**Size**|**UL Type 1 and UL Type 12**|**UL Type 3R**|
|**B**|See**Page V6-T2-224**|See**Page V6-T2-226**|
|**C**|See**Page V6-T2-225**|See**Page V6-T2-227**|
|**D**|N/A|See**Page V6-T2-228**|
|**F**|N/A|See**Page V6-T2-229**|
|**7**2|See**Page V6-T2-230**|3|
|**8**2|See**Page V6-T2-231**|3|
|**9**|See**Page V6-T2-232**|3|
## _**Notes**_
1 Consult factory.
2 Enclosures 7 and 8 are NEMA 12 filtered.
3 Not available for UL Type 3R.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-213**
Adjustable Frequency Drives
2.8
**2** ~~7~~
## Low Harmonic Drives
## **575V Drives**
**Enclosed Passive Filtered Drive**
## **UL Type 1, UL Type 12, UL Type 3R and NEMA 12 Filtered**
**==> picture [413 x 408] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||
|---|---|---|---|---|---|
|NEC|Chassis|UL Type 1|UL Type 12 and NEMA 12 Filtered|UL Type 3R|
|hp|Current (A)|Frame|Base Catalog Number|Base Catalog Number|Base Catalog Number|
|Low Overload Drive|
|15|17|FR6|1|CFX01525AA|CFX01535AA|
|20|22|FR6|1|CFX02025AA|CFX02035AA|
|25|27|FR6|1|CFX02525AA|CFX02535AA|
|30|32|FR6|1|CFX03025AA|CFX03035AA|
|40|41|FR7|1|CFX04025AA|CFX04035AA|
|50|52|FR7|1|CFX05025AA|CFX05035AA|
|60|62|FR8|CFX06015AA|CFX06065AA|CFX06035AA|
|75|77|FR8|CFX07515AA|CFX07565AA|CFX07535AA|
|100|99|FR8|CFX10015AA|CFX10065AA|CFX10035AA|
|125|125|FR9|CFX12515AA|CFX12565AA|CFX12535AA|
|150|144|FR9|CFX15015AA|CFX15065AA|CFX15035AA|
|200|192|FR9|CFX20015AA|CFX20065AA|CFX20035AA|
|250|242|FR10|CFX25015AA|CFX25065AA|2|
|300|289|FR10|CFX30015AA|CFX30065AA|2|
|400|382|FR10|CFX40015AA|CFX40065AA|2|
|High Overload Drive|
|10|14|FR6|1|CFX01025DA|CFX01035DA|
|15|17|FR6|1|CFX01525DA|CFX01535DA|
|20|22|FR6|1|CFX02025DA|CFX02035DA|
|25|27|FR6|1|CFX02525DA|CFX02535DA|
|30|32|FR7|1|CFX03025DA|CFX03035DA|
|40|41|FR7|1|CFX04025DA|CFX04035DA|
|50|52|FR8|CFX05015DA|CFX05065DA|CFX05035DA|
|60|62|FR8|CFX06015DA|CFX06065DA|CFX06035DA|
|75|77|FR8|CFX07515DA|CFX07565DA|CFX07535DA|
|100|99|FR9|CFX10015DA|CFX10065DA|CFX10035DA|
|125|125|FR9|CFX12515DA|CFX12565DA|CFX12535DA|
|150|144|FR9|CFX15015DA|CFX15065DA|CFX15035DA|
|200|192|FR10|CFX20015DA|CFX20065DA|2|
|250|242|FR10|CFX25015DA|CFX25065DA|2|
|300|289|FR10|CFX30015DA|CFX30065DA|2|
**----- End of picture text -----**<br>
## _**Notes**_
- 1 FR6–FR7 drives not available in UL Type 1.
- 2 Consult factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-214**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Enclosed Passive Filtered Drive Enclosure**
|**Enclosed Passive Filtered Drive Enclosure**||
|---|---|
|**Chassis**<br>**Frame**<br>**UL Type 1**<br>**Disconnect Only**<br>**With Power Options**<br>FR6<br>N/A<br>N/A<br>FR7<br>N/A<br>7<br>FR8<br>7<br>7<br>FR9<br>8<br>8<br>FR10<br>9<br>9|**UL Type 12**<br>**Disconnect Only**<br>**With Power Options**|
||B<br>C|
||C<br>7|
||7<br>7|
||8<br>8|
||9<br>9|
|**UL Type 3R**<br>**Disconnect Only**<br>**With Power Options**<br>B<br>C<br>C<br>D<br>F<br>F<br>F<br>F<br>1<br>1|**2**|
|---|---|
||**2**|
||**2**<br>**2**|
## **Enclosure Dimension Drawings**
|**Enclosure**|||
|---|---|---|
|**Size**|**UL Type 1 and UL Type 12**|**UL Type 3R**|
|**B**|See**Page V6-T2-224**|See**Page V6-T2-226**|
|**C**|See**Page V6-T2-225**|See**Page V6-T2-227**|
|**D**|N/A|See**Page V6-T2-228**|
|**F**|N/A|See**Page V6-T2-229**|
|**7**2|See**Page V6-T2-230**|3|
|**8**2|See**Page V6-T2-231**|3|
|**9**|See**Page V6-T2-232**|3|
## _**Notes**_
1 Consult factory.
2 Enclosures 7 and 8 are NEMA 12 filtered.
3 Not available for UL Type 3R.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-215**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Options**
## **Enclosed Passive Filtered Drive Option Board Kits**
**2**
The enclosed passive filtered drive series can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is designed to accept a total of five option boards.
The enclosed passive filtered drive series factory-installed standard board configuration includes an A9 I/O board and an A2 relay output board, which are installed in slots A and B.
## **Option Boards**
**==> picture [54 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B [C] [D] [E]<br>**----- End of picture text -----**<br>
## **Option Board Kits**
||**Option Board Kits**|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
||||**Field**<br>**Installed**|**Factory**<br>**Installed**|**SVX Ready Programs**|||||||
|||**Allowed Slot**|**Catalog**|**Option**||**Local/**||||||
||**Option Kit Description**1|**Locations**2|**Number**|**Designator**|**Basic**|**Remote**|**Standard**|**MSS**|**PID**|**Multi-P.**|**PFC**|
||**Standard I/O Cards**<br>2 RO (NC/NO)|B|**OPTA2**|**—**|■|■|■|■|■|■|■|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/ext +24 Vdc|A|**OPTA9**|**—**|■|■|■|■|■|■|■|
||**Extended I/O Cards**<br>6 DI|B, C,**D**, E|**OPTB1**|**B1**|—|—|—|—|—|■|■|
||1 RO (NC/NO), 1 RO (NO), 1 therm|B, C,**D**, E|**OPTB2**|**B2**|—|—|—|—|—|■|■|
||1 AI (mA isolated), 2 AO (mA isolated)|B, C,**D**, E|**OPTB4**|**B4**|■|■|■|■|■|■|■|
||3 RO (NO)|B, C,**D**, E|**OPTB5**|**B5**|—|—|—|—|—|■|■|
||3 Pt100 RTD board|B, C,**D**, E|**OPTB8**|**B8**|—|—|—|—|—|■|—|
||1 RO (NO), 5 DI 42–240 Vac input|B, C,**D**, E|**OPTB9**|**B9**|—|—|—|—|—|■|■|
||**Communication Cards**3<br>Modbus|D,**E**|**OPTC2**|**C2**|■|■|■|■|■|■|■|
||Modbus TCP|D,**E**|**OPTCI**|**CI**|■|■|■|■|■|■|■|
||BACnet|D,**E**|**OPTCJ**|**CJ**|■|■|■|■|■|■|■|
||EtherNet/IP|D,**E**|**OPTCQ**|**CQ**|■|■|■|■|■|■|■|
||Johnson Controls N2|D,**E**|**OPTC2**|**CA**|■|■|■|■|■|■|■|
||PROFIBUS DP|D,**E**|**OPTC3**|**C3**|■|■|■|■|■|■|■|
||LonWorks<br>PROFIBUS DP (D9 connector)|D,**E**<br>D,**E**|**OPTC4**<br>**OPTC5**|**C4**<br>**C5**|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|
||CANopen (slave)|D,**E**|**OPTC6**|**C6**|■|■|■|■|■|■|■|
||DeviceNet|D,**E**|**OPTC7**|**C7**|■|■|■|■|■|■|■|
||Modbus (D9 type connector)|D,**E**|**OPTC8**|**C8**|■|■|■|■|■|■|■|
||RS-232 with D9 connection|D,**E**|**OPTD3**|**D3**|■|■|■|■|■|■|■|
## _**Notes**_
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
- 3 OPTC2 is a multi-protocol option card.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-216**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## _**Modbus RTU Network Communications**_
The Modbus Network Card OPTC2 is used for connecting the 9000X Drive as a slave on a Modbus network. The interface is connected by a 9-pin DSUB connector (female) and the baud rate ranges from 300 to 19,200 baud. Other communication parameters include an address range from 1 to 247; a parity of None, Odd or Even; and the stop bit is 1.
## _**PROFIBUS Network**_
## _**Communications**_
The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS-DP network. The interface is connected by a 9-pin DSUB connector (female). The baud rates range from 9.6K baud to 12M baud, and the addresses range from 1 to 127.
## _**LonWorks Network Communications**_
The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network. This interface uses Standard Network Variable Types (SNVT) as data types. The channel connection is achieved using a FTT-10A Free Topology transceiver via a single twisted transfer cable. The communication speed with LonWorks is 78 kBits/s.
## _**CANopen (Slave) Communications**_
The CANopen (Slave) Network Card OPTC6 is used for connecting the 9000X Drive to a host system. According to ISO[®] 11898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms, and specific line delay of nominal 5 as/m. 120 ohm line termination resistors required for installation.
## _**DeviceNet Network Communications**_
The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network. It includes a 5.08 mm pluggable connector. Transfer method is via CAN using a two-wire twisted shielded cable with two-wire bus power cable and drain. The baud rates used for communication include 125K baud, 250K baud and 500K baud.
## _**Johnson Controls Metasys N2 Network Communications**_
The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. The N2 fieldbus is available as a factory-installed option and as a field-installable kit.
## _**Modbus/TCP Network Communications**_
The Modbus/TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks using Modbus protocol. It includes an RJ-45 pluggable connector. This interface provides a selection of standard and custom register values to communicate drive parameters. The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable over Ethernet using a supplied software tool.
## _**BACnet Network Communications**_
The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks. It includes a 5.08 mm pluggable connector. Data transfer is Master-Slave/ Token Passing (MS/TP) RS-485. This interface uses a collection of 30 Binary Value Objects (BVOs) and 35 Analog Value Objects (AVOs) to communicate drive parameters. The card supports 9.6, 19.2 and 38.4 Kbaud communication speeds and supports network addresses 1 to 127.
## _**Ethernet/IP Network Communications**_
The Ethernet/IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet/Industrial Protocol networks. It includes an RJ45 pluggable connector. The interface uses CIP objects to communicate drive parameters (CIP is “Common Industrial Protocol,” the same protocol used by DeviceNet). The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable by Static, BOOTP and DHCP methods.
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-217**
Adjustable Frequency Drives
2.8
## Low Harmonic Drives
## **Control/Communication Option Descriptions**
|**2**|**Control/Communication Option Descriptions**|**Control/Communication Option Descriptions**||
|---|---|---|---|
|**2**|**Available Control/Communications Options**<br>**Option**<br>**Description**||**Option Type**|
|||||
|**2**|**K1**|**Door-Mounted Speed Potentiometer**—Provides the drive with the ability to adjust the frequency reference using a door-mounted potentiometer. This option uses the<br>10 Vdc reference to generate a 0–10V signal at the analog voltage input signal terminal. When the HOA bypass option is added, the speed is controlled when the HOA|Control|
|||switch is in the HAND position. Without the HOA bypass option, a two-position switch (labeled local/remote) is provided on the keypad to select speed reference from the speed||
|**2**||potentiometer or a remote speed signal.||
||**K2**|**Door-Mounted Speed Potentiometer with HOA Selector Switch**—Provides the drive with the ability to start/stop and adjust the speed reference from door-|Control|
|**2**||mounted control devices or remotely from customer supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-mounted speed<br>potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry contact and||
|**2**|**K3**|4–20 mA signal.<br>**3–15 psig Follower**—Provides a pneumatic transducer which converts a 3–15 psig pneumatic signal to either 0–8 Vdc or a 1–9 Vdc signal interface with the drive.|Control|
|**2**||The circuit board is mounted on the inside of the front enclosure panel and connects to the user’s pneumatic control system via 6 ft (1.8m) of flexible tubing and a 1/4 in<br>(6.4 mm) brass tube union.||
||**K4**|**HAND/OFF/AUTO Switch for Non-Bypass Configurations**—Provides a three-position selector switch that allows the user to select either a HAND or AUTO mode of|Control|
|**2**||operation. HAND mode is defaulted to keypad operation, and AUTO mode is defaulted to control from an external terminal source. These modes of operation can be<br>configured via drive programming to allow for alternate combinations of start and speed sources. Start and speed sources include keypad, I/O and fieldbus.||
|**2**|**K5**|**MANUAL/AUTO Speed Reference Switch**—Provides door-mounted selector switch for MANUAL/AUTO speed reference.|Control|
||**K6**|**START/STOP Pushbuttons**—Provide door-mounted START and STOP pushbuttons for either bypass or non-bypass configurations.|Control|
|**2**|**KF**|**Bypass Test Switch for RB and RA**—Allows the user to energize the AF drive for testing while operating the motor on the bypass controller. The Test Switch is|Addl. bypass|
|||mounted on the inside of the enclosure door.||
|**2**|**KO**|**Standard Elapsed Time Meter**—Provides a door-mounted elapsed run time meter.|Control|
||**L1**|**Power On, Run and Fault Lights**—Provide a white power on light that indicates power to the enclosed cabinets, a green run light and a red fault light that indicates a|Light|
|**2**||drive fault has occurred.||
||**L2**|**Bypass Pilot Lights for RB, RA Bypass Options**—A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is|Addl. bypass|
|**2**||running in bypass mode. The lights are mounted on the enclosure door, above the switches.||
||**LE**|**Red Run Pilot Light (22 mm)**—Provides a red run pilot light that indicates the drive is running.|Light|
|**2**|**P1**|**Input Circuit Breaker**—High interrupting circuit breaker that provides a means of short-circuit protection for the power cables between it and the enclosed 18-pulse|Input|
|||drive, and protection from high-level ground faults on the power cable. Allows a convenient means of disconnecting the enclosed 18-pulse drive from the line and the operating||
|**2**||mechanism can be padlocked in the OFF position. This is factory mounted in the enclosure. Standard rating is 65 kAIC at 208/480V. 100 kAIC is available as an option.||
||**P3**|**Input Line Fuses Rated to 200 kAIC**—Provide high-level fault protection of the drive input power circuit from the load side of the fuses to the input side of the power|Input|
|**2**|**P7**|transistors. This option consists of three 200 kA fuses, which are factory mounted in the enclosure.<br>**MOV Surge Suppressor**—Provides a Metal Oxide Varistor (MOV) connected to the line side terminals and is designed to clip line side transients.|Input|
|**2**|**P8**|**TVSS Surge Protective Device with 50 kA Rating**—Provides transient voltage protection eliminating surges and spikes which can damage the diode bridge<br>of the drive.|Input|
|**2**|**PC**|**Capacitor Contactor**—This option provides a contactor between the tuned reactor and capacitor to disconnect the capacitor from the circuit when desired, typically at<br>light or no load conditions. This contactor is wired to a programmable relay output.|Input|
|**2**|**PE**|**Output Contactor**—Provides a means for positive disconnection of the drive output from the motor terminals. The contactor coil is controlled by the drive’s run or<br>permissive logic. NO auxiliary contacts rated at 10A, 600 Vac are provided for customer use. Bypass options**RB**and**RA**include an output contactor as standard.|Output|
|||This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure.||
|**2**|**PF**|**Output Filter**—Used to reduce the transient voltage (DV/DT) at the motor terminals. The output filter is recommended for cable lengths exceeding 100 ft (30m) or for a|Output|
|||drive rated at 525–690V. This option is mounted in the enclosure, and may be used in conjunction with a brake chopper circuit.||
|**2**|**PG**|**MotoRx (300–600 ft) 1000 V/μS DV/DT Filter**—Used to reduce transient voltage (DV/DT) and peak voltages at the motor terminals. This option is comprised of a 0.5%|Output|
|||line reactor, followed by capacitive filtering and an energy recovery/clamping circuit. Unlike the output filter (see option**PF**), the MotoRx recovers most of the energy from the||
|**2**||voltage peaks, resulting in a lower voltage drop to the motor, and therefore conserving power. This option is used when the distance between a single motor and the drive<br>is 300–600 ft (91–183m)._This option cannot be used with the brake chopper circuit. The output filter (option_**_PF_**_) should be investigated as an alternative._||
|**2**|**PH**|**Single Overload Relay**—Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options. It is<br>included with the bypass configurations for overload current protection in the bypass mode. The overload relay is mounted within the enclosure, and is manually|Output|
|||resettable. Heater pack included.||
|**2**|**PI**|**Dual Overload Relays**—This option is recommended when a single drive is operating two motors and overload current protection is needed for each of the motors. The|Output|
|||standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a 100 hp drive would include||
|**2**||two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable. Heater packs not included.||
||**PN**|**Dual Overloads for Bypass**—This option is recommended when a single drive is operating two motors in the bypass mode and overload current protection is needed|Addl. bypass|
|**2**||for each of the motors. The standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a<br>100 hp drive would include two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable.||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-218**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Available Control/Communications Options, continued**
|**Option**|**Description**|**Option Type**|
|---|---|---|
|**RA**|**Manual HOA Bypass Controller**—The manual HAND/OFF/AUTO (HOA)—three-contactor—bypass option provides a means of bypassing the enclosed passive<br>filtered drive, allowing the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input HMCP, a fused control power|Bypass|
||transformer, and a full voltage bypass starter with a door-mounted HOA selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start<br>and stop the drive in the inverter mode. IEC type input, bypass and input contactors are provided. The contactors are mechanically and electrically interlocked (see wiring||
||diagram on**Page** **V6-T2-223**).||
|**RB**|**Manual IOB Bypass Controller**—The manual INVERTER/OFF/BYPASS (IOB)—three-contactor—bypass option provides a means of bypassing the enclosed passive|Bypass|
||filtered drive, allowing the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input HMCP, a fused control power||
||transformer, and a full voltage bypass starter with a door-mounted IOB selector switch. IEC type input, bypass and input contactors are provided. The contactors are<br>mechanically and electrically interlocked (see wiring diagram on**Page** **V6-T2-223**).||
|**RC**|**Auto Transfer HOA Bypass Controller**—The manual HAND/OFF/AUTO (HOA)—three-contactor—bypass option provides a means of bypassing the enclosed passive<br>filtered drive, allowing the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the|Bypass|
||line” operation after a drive trip. This option consists of an input HMCP, a fused control power transformer, and a full voltage bypass starter with a door-mounted HOA||
||selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in either mode. IEC type input, bypass and input<br>contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on**Page** **V6-T2-223**). Door-mounted pilot lights are provided||
||that indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in||
||bypass mode.<br>**WARNING**: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.||
|**RD**|**Auto Transfer IOB Bypass Controller**—The auto INVERTER/OFF/BYPASS (IOB)—three-contactor—bypass option provides a means of bypassing the enclosed passive<br>filtered drive, allowing the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the|Bypass|
||line” operation after a drive trip. This option consists of an input HMCP, a fused control power transformer, and a full voltage bypass starter with a door-mounted IOB<br>selector switch. IEC type input, bypass and input contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on**Page**<br>**V6-T2-223**). Door-mounted pilot lights are provided that indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an||
||amber light indicates when the motor is running in bypass mode.<br>**WARNING**: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.||
|**RG**|**Reduced Voltage Starter for Bypass**—Used in conjunction with bypass option RA, RB, RC or RD. This option adds**_IT._**Series reduced voltage soft starter to bypass<br>assembly for soft starting in bypass mode.|Bypass|
|**S4**<br>**S5**|**Floor Stand 6 in**—Raises “F” box off the ground 6 in (152.4 mm). Recommended when box is not installed on an appropriate concrete pad.<br>**Floor Stand 22 in**—Converts a Size B or C, normally wall mounted enclosure to a floor standing enclosure with a height of 22 in (558.8 mm).|Enclosure<br>Enclosure|
|**S6**<br>**S9**|**Floor Stand 12 in**—Converts a Size C or D, normally wall mounted enclosure to a floor standing enclosure with a height of 12 in (304.8 mm).<br>**Space Heater**—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature control.|Enclosure<br>Enclosure|
||Heater requires a customer supplied 115V remote supply source.||
**2**
## **Enclosed Drive Options**
## **Conformal (Varnished) Coating**[1]
|**Chassis**<br>**Frame**<br>**Delivery**<br>**Code**<br>FR6<br>FP<br>FR7<br>FP<br>FR8<br>FP<br>—<br>—|**Chassis**<br>**Frame**<br>**Delivery**<br>**Code**|
|---|---|
||FR9<br>FP|
||FR10<br>FP|
||FR11<br>FP|
||FR12<br>FP|
## **Light Options**
|**Description**<br>Power on, run, fault LED lights (22 mm)|**Catalog**<br>**Number Suffix**<br>**L1**|
|---|---|
|Power on, fault LED lights (22 mm)|**L3**|
|Green LED run light (22 mm)<br>Green LED stop light (22 mm)|**LA**<br>**LD**|
|Red LED run light (22 mm)|**LE**|
|Red LED stop light (22 mm)|**LF**|
|Red LED fault light (22 mm)|**LG**|
|Power on white LED light (22 mm)<br>Miscellaneous LED light (22 mm)|**LJ**<br>**LU**|
## **Control Options**
|**Description**|**Catalog**<br>**Number Suffix**|
|---|---|
|Door-mounted speed potentiometer|**K1**|
|Door-mounted speed potentiometer with HOA selector switch|**K2**|
|3–15 psig follower|**K3**|
|HOA selector switch|**K4**|
|MANUAL/AUTO reference switch|**K5**|
|START-STOP pushbuttons<br>Type D2 control relay|**K6**<br>**SD**|
|On-delay relay|**SE**|
|Off-delay relay|**SF**|
|Additional terminal blocks per 4 points|**SD**|
## _**Note**_
> 1 See catalog number description to order.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-219**
## 2.8
## Adjustable Frequency Drives
## Low Harmonic Drives
## **Bypass Control Options**
||**Ba Cntrl Otin**|
|---|---|
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**|**ypss oo pos**<br>**Description**<br>**Catalog**<br>**Number Suffix**|
||Bypass test switch used with RA and RB<br>**KF**|
||Inverter/bypass pilot lights<br>**L2**|
||**Meter Options**<br>**Description**<br>**Catalog**<br>**Number Suffix**|
||Standard elapsed time meter<br>**KO**|
||Frequency meter<br>**KS**|
||MP-3000 relay with URTD<br>**KV**|
||MP-3000 relay with URTD and CTs<br>**KU**|
## **Enclosure Options**
|**Enclosure Options**||
|---|---|
|**Enclosure**|**Catalog**|
|**Size**|**Number Suffix**|
|**Space Heater**1||
|7|**S9**|
|8|**S9**|
|9|**S9**|
|B<br>C|**S9**<br>**S9**|
|D<br>F|**S9**<br>**S9**|
|**Plastic Nameplate**||
|All|**SN**|
|**Floor Stand/Enclosure Size**||
|6 in floor stand, size F|**S4**|
|22 in floor stand, size B and C|**S5**|
|12 in floor stand, size C and D|**S6**|
## **208V Power Options, 7-1/2–100 hp**
||**Catalog**|
|---|---|
|**Description**<br>Input breaker|**Number Suffix**<br>**P1**|
|Input line fusing|**P2**|
|Input line fuses 200 kAIC|**P3**|
|Output contactor|**PE**|
|Single overload relay|**PH**|
|Dual overload relays|**PI**|
|MOV|**P7**|
|50 kA surge protective device|**P8**|
|100 kA surge protective device|**P9**|
## **230V Power Options, 7-1/2–125 hp**
|**Description**|**Catalog**<br>**Number Suffix**|
|---|---|
|Input breaker|**P1**|
|Input line fusing|**P2**|
|Input line fuses 200 kAIC|**P3**|
|Output contactor|**PE**|
|Single overload relay|**PH**|
|Dual overload relays<br>MOV|**PI**<br>**P7**|
|50 kA surge protective device<br>100 kA surge protective device|**P8**<br>**P9**|
## **480 and 575V Power Options, 7-1/2–400 hp**
||**Catalog**|
|---|---|
|**Description**|**Number Suffix**|
|Input breaker|**P1**|
|Input line fusing|**P2**|
|Input line fuses 200 kAIC|**P3**|
|Output contactor|**PE**|
|Output filter|**PF**|
|MotoRx (300–600 ft) DV/DT filter|**PG**|
|Single overload relay|**PH**|
|Dual overload relays|**PI**|
|Input MOV|**P7**|
|50 kA surge protective device|**P8**|
|100 kA surge protective device|**P9**|
## **208V Bypass Options, 7-1/2–100 hp**
||**Catalog**|
|---|---|
|**Description**|**Number Suffix**|
|Manual HOA bypass controller|**RA**|
|IOB bypass controller|**RB**|
|Auto transfer HOA bypass controller|**RC**|
|Auto transfer IOB bypass controller|**RD**|
|Reduced voltage starter for bypass|**RG**|
|Dual overloads for bypass|**PN**|
## **230V Bypass Options, 7-1/2–125 hp**
||**Catalog**|
|---|---|
|**Description**|**Number Suffix**|
|Manual HOA bypass controller|**RA**|
|IOB bypass controller|**RB**|
|Auto transfer HOA bypass controller|**RC**|
|Auto transfer IOB bypass controller|**RD**|
|Reduced voltage starter for bypass|**RG**|
|Dual overloads for bypass|**PN**|
## **480 and 575V Bypass Options, 7-1/2–400 hp**
||**Catalog**|
|---|---|
|**Description**|**Number Suffix**|
|Manual HOA bypass controller|**RA**|
|IOB bypass controller|**RB**|
|Auto transfer HOA bypass controller|**RC**|
|Auto transfer IOB bypass controller|**RD**|
|Reduced voltage starter for bypass|**RG**|
|Dual overloads for bypass|**PN**|
## _**Note**_
> 1 Requires customer-supplied 115 Vac supply.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-220**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
**2**
## **Technical Data and Specifications**
|**Enclosed Passive Filtered**|**Drives**|
|---|---|
|**Description**|**Specification**|
|**Primary Design Features**||
|45–66 Hz input frequency|Standard|
|Output: AC volts maximum|Input Voltage Base|
|Output frequency range|0–320 Hz|
|Initial output current (IH)|250% for 2 seconds|
|Overload (1 minute [IH/IL])|150%/110%|
|Enclosure space heater|Optional|
|Oversize enclosure|Standard|
|Output contactor|Optional|
|Bypass motor starter|Optional|
|Listings|UL, cUL, 508C|
|**Protection Features**||
|Incoming line fuses|Optional|
|AC input circuit disconnect|Optional|
|Phase rotation insensitive|Standard|
|EMI filter|Standard—FR6 thru FR91|
|Input phase loss protection|Standard|
|Input overvoltage protection|Standard|
|Line surge protection|Standard|
|Output short-circuit protection|Standard|
|Output ground fault protection|Standard|
|Output phase protection|Standard|
|Overtemperature protection|Standard|
|DC overvoltage protection|Standard|
|Drive overload protection|Standard|
|Motor overload protection|Standard|
|Programmer software|Optional|
|Local/remote keypad|Standard|
|Keypad lockout|Standard|
|Fault alarm output|Standard|
|Built-in diagnostics|Standard|
|Surge protective device|Optional|
|**Description**|**Specification**|
|---|---|
|**Input/Output Interface Features**||
|Setup adjustment provisions||
|Remote keypad/display|Standard|
|Personal computer<br>Operator control provisions|Standard|
|Drive mounted keypad/display|Standard|
|Remote keypad/display|Standard|
|Conventional control elements|Standard|
|Serial communications<br>115 Vac control circuit|Optional<br>Optional|
|Speed setting inputs<br>Keypad|Standard|
|0–10 Vdc potentiometer/voltage signal|Standard|
|4–20 mA isolated|Configurable|
|4–20 mA differential|Configurable|
|3–15 psig<br>Analog outputs|Optional|
|Speed/frequency|Standard|
|Torque/load/current|Programmable|
|Motor voltage|Programmable|
|Kilowatts|Programmable|
|0–10 Vdc signals|Configurable w/jumpers|
|4–20 mA DC signals<br>Isolated signals|Standard<br>Optional|
|Discrete outputs||
|Fault alarm|Standard|
|Drive running|Standard|
|Drive at set speed<br>Optional parameters|Programmable<br>14|
|Dry contacts<br>Open collector outputs|2 relays Form C<br>1|
|Additional discrete outputs|Optional|
|**Communications**||
|RS-232|Standard|
|RS-422/485<br>DeviceNet™|Optional<br>Optional|
|Modbus RTU|Optional|
|CANopen (slave)|Optional|
|PROFIBUS-DP|Optional|
|Lonworks®|Optional|
|Johnson Controls Metasys™ N2|Optional|
|EtherNet/IP/Modbus TCP<br>BACnet|Optional<br>Optional|
## _**Note**_
> 1 The EMI filter is optional in FR10.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-221**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
**2**
## **Enclosed Passive Filtered Drives, continued**
|**Description**|**Specification**|
|---|---|
|**Performance Features**||
|Sensorless vector control|Standard|
|Volts/hertz control|Standard|
|IR and slip compensation<br>Electronic reversing|Standard<br>Standard|
|Dynamic braking|Optional|
|DC braking|Standard|
|PID setpoint controller|Programmable|
|Critical speed lockout|Standard|
|Current (torque) limit|Standard|
|Adjustable acceleration/deceleration<br>Linear or S curve accel/decel|Standard<br>Standard|
|Jog at preset speed|Standard|
|Thread/preset speeds|7|
|Automatic restart|Selectable|
|Coasting motor start<br>Coast or ramp stop selection|Standard<br>Standard|
|Elapsed time meter|Optional|
|**Standard Conditions for Application and Service**||
|Maximum operating ambient temperature|0 to 40°C, contact factory for 50°C1|
|Storage temperature|–40 to 60°C|
|Humidity (maximum), non-condensing|95%|
|Altitude|100% load capacity (no derating) up to<br>3280 ft (1000m);|
||1% derating for each 328 ft (100m) above|
||3280 ft (1000m); max. 9842 ft (3000m)|
|Line voltage variation|+10/–15%|
|Line frequency variation|45–66 Hz|
|Efficiency|>96%|
|Power factor (displacement)|0.99|
## **Standard I/O Specifications**
|**Description**|**Specification**|
|---|---|
|Six–digital input programmable|24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V,Ri>5 kohms|
|Two–analog input configurable w/|Voltage: 0–±10V, Ri>200 kohms|
|jumpers|Current: 0 (4)–20 mA, Ri= 250 kohms|
|Two–digital output programmable|Form C relays 250 Vac or 30 Vdc 2 Amp resistive|
|One–digital output programmable|Open collector 48 Vdc 50 mA|
|One–analog output programmable|0–20 mA, RLmax. 500 ohms 10 bits ±2%|
|configurable w/jumper||
## **I/O Specifications for Control/Communication Options**
|**Description**|**Specification**|
|---|---|
|Analog voltage, input|0–±10V, Ri ><br>~~2~~00 kilohms|
|Analog current, input|0 (4)–20 mA, Ri= 250 ohms|
|Digital input|24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V, Ri>5 kilohms|
|Auxiliary voltage|24V (±20%), max. 50 mA|
|Reference voltage|10V ±3%, max. 10 mA|
|Analog current, output|0 (4)–20 mA, RL= 500 kilohms, resolution|
||10 bit, accuracy <<br>~~±~~2%|
|Analog voltage, output|0 (2)–10V, RL ><br>~~1~~kohm, resolution|
||10 bit, accuracy <<br>~~±~~2%|
|Relay output max. switching voltage|300 Vdc, 250 Vac|
|Relay output max. switching load|3A/24 Vdc, 300 Vdc, 250 Vac2|
|Relay output max. continuous load|2A rms|
|Thermistor input|Rtrip= 4.7 kohms|
## _**Notes**_
> 1 Units FR10 rated 40°C.
> 2 For applications above 3A consult instruction manual.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-222**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Wiring Diagram**
## **Control Input/Output**
**2**
## **Basic Application Default I/O Configuration**
|Remote reference<br>(4)–20 mA<br>mA<br>READY<br>RUN<br>Reference potentiometer<br>1–10 kohms|Remote reference<br>(4)–20 mA<br>mA<br>READY<br>RUN<br>Reference potentiometer<br>1–10 kohms|**Terminal**|**Terminal**|**Terminal**|**Signal**<br>**Description**|
|---|---|---|---|---|---|
|||**OPTA9**||||
|||1<br>+10Vref|||Reference output<br>Voltage for potentiometer, etc.|
|||2<br>AI1+|||Analog input, voltage range 0–10 Vdc<br>Voltage input frequency reference|
|||3<br>AI1–|||I/O Ground<br>Ground for reference and controls|
|||4<br>AI2+|||Analog input, current range 0–20 mA<br>Current input frequency reference|
|||5<br>AI2–||||
|||6<br>+24V|||Control voltage output<br>Voltage for switches, etc. max 0.1A|
|||||||
|||7<br>GND|||I/O ground<br>Ground for reference and controls|
|||8|DIN1||Start forward<br>Contact closed = start forward|
|||||||
|||9|DIN2||Start reverse<br>Contact closed = start reverse|
|||||||
|||10|DIN3||External fault input (programmable)<br>Contact open = no fault<br>Contact closed = fault|
|||||||
|||11|CMA||Common for DIN 1–DIN 3<br>Connect to GND or +24V|
|||12|+24V||Control voltage output<br>Voltage for switches (see terminal 6)|
|||13|GND||I/O ground<br>Ground for reference and controls|
|||||||
|||14|DIN4||Multi-step speed select 1<br>**DIN4**<br>**DIN5**<br>**Frequency Ref.**|
|||||||
|||15|DIN5||Multi-step speed select 2<br>Open<br>Closed<br>Open<br>Closed<br>Open<br>Open<br>Closed<br>Closed<br>Ref.Vin<br>Multi-step ref.1<br>Multi-step ref.2<br>RefMax|
|||||||
|||16|DIN6||Fault reset<br>Contact open = no action<br>Contact closed = fault reset|
|||||||
|||17|CMB||Common for DIN4–DIN6<br>Connect to GND or +24V|
|||18|AO1+||Output frequency<br>Analog output<br>Programmable<br>Range 0–20 mA, RLmax. 500 ohms|
|||||||
|||19|AO1–|||
|||||||
|||20|DO1||Digital output<br>Programmable|
|||||||
||||||<br>READY<br><br>Open collector, I <<br>~~5~~0 mA, V <<br>~~4~~8 Vdc|
|||**OPTA2**||||
|||21<br>RO1|||Relay output 1<br>RUN|
|||22<br>RO1||||
|||23<br>RO1||||
|||24<br>RO2|||Relay output 2<br>FAULT|
|||25<br>RO2||||
|||26<br>RO2||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-223**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2 Enclosure Size B—UL Type 12**
|||4.00 (101.6)<br>Minimum Free Air<br>Space Required|4.00 (101.6)<br>Minimum Free Air<br>Space Required|4.00 (101.6)<br>Minimum Free Air<br>Space Required|**W1**<br>**D**<br>3.00 (76.2)<br>Minimum Air<br>Space<br>Required<br>Both Sides<br>D1<br>0.44 (11.2)<br>Mounting<br>Holes<br>(4 Places)|**W1**<br>**D**<br>3.00 (76.2)<br>Minimum Air<br>Space<br>Required<br>Both Sides<br>D1<br>0.44 (11.2)<br>Mounting<br>Holes<br>(4 Places)|**W1**<br>**D**<br>3.00 (76.2)<br>Minimum Air<br>Space<br>Required<br>Both Sides<br>D1<br>0.44 (11.2)<br>Mounting<br>Holes<br>(4 Places)|**W1**<br>**D**<br>3.00 (76.2)<br>Minimum Air<br>Space<br>Required<br>Both Sides<br>D1<br>0.44 (11.2)<br>Mounting<br>Holes<br>(4 Places)||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||<br><br>s<br>D1||||||
|H2<br>1||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
||||||||D1|||||
|||W1<br>W|||||||D|||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||**H1**<br>**H2**||**W**||||||||
|0.00<br>1016.0)||38.00<br>(965.2)<br>36.35<br>(923.3)||20.92<br>(531.4)|19.30<br>(490.2)<br>16.76<br>(425.7)||||2.34<br>(59.4)<br>185 (84)<br>229 (104)|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-224**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size C—UL Type 12**
|0.44 (11.2<br>Mountin<br>Holes<br>|0.44 (11.2<br>Mountin<br>Holes<br>|**H1**<br>**H2**<br>**H3**<br>**H4**<br>**W**<br><br>H<br>0.44<br>Mou<br>Ho<br>(4 Pl<br>3.00 (76.2)<br>Minimum Air Space<br>Required Both Sides<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>H<br>D1<br>W<br>W1<br>D<br>)<br>g<br>)|**H1**<br>**H2**<br>**H3**<br>**H4**<br>**W**<br><br>H<br>0.44<br>Mou<br>Ho<br>(4 Pl<br>3.00 (76.2)<br>Minimum Air Space<br>Required Both Sides<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>H<br>D1<br>W<br>W1<br>D<br>)<br>g<br>)|**H1**<br>**H2**<br>**H3**<br>**H4**<br>**W**<br><br>H<br>0.44<br>Mou<br>Ho<br>(4 Pl<br>3.00 (76.2)<br>Minimum Air Space<br>Required Both Sides<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>H<br>D1<br>W<br>W1<br>D<br>)<br>g<br>)|(11.2)<br>nting<br>les<br>aces)|4.00 (101.6) Minimum<br>Free Air Space Required<br>W1|4.00 (101.6) Minimum<br>Free Air Space Required<br>W1|4.00 (101.6) Minimum<br>Free Air Space Required<br>W1|4.00 (101.6) Minimum<br>Free Air Space Required<br>W1|4.00 (101.6) Minimum<br>Free Air Space Required<br>W1|
|---|---|---|---|---|---|---|---|---|---|---|
|4 Places||<br>)|||||||||
||||||||||||
|H2<br>1|||||H2<br>4||||||
||||||||||||
|||W|1||||W||||
||||||||||||
||||||||||||
||||||||||||
||||||**W1**||||||
||||||||||||
|||**H1**|||||||||
||||||||||||
||||||||||||
|2.00<br>1320.8)||50.00<br>(1270.0)|48.35<br>(1228.1)<br>72.00<br>(1828.8)|71.19<br>(1808.2)<br>30.92<br>(785.4)<br><br>(|29.30<br>744.2)|16.78<br>(426.2)<br>2.34<br>(59.4)<br>320 (145)<br>435 (197)|||||
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-225**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size B—UL Type 3R**
**==> picture [370 x 385] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 W D<br>2<br>2<br>2<br>2<br>2<br>2<br>H2<br>2 H1 H<br>2 H3<br>2<br>2<br>2<br>2<br>2<br>W2<br>2 W3 W1 D2 D1<br>0.44 (11.2)<br>2 Mounting<br>Holes<br>(4 Places)<br>2<br>2<br>**----- End of picture text -----**<br>
||||||||||||**Approximate**|**Approximate**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
||||||||||||**Weight**|**Shipping Weight**|
|**H**|**H1**|**H2**|**H3**|**W**|**W1**|**W2**|**W3**|**D**|**D1**|**D2**|**Lbs (kg)**|**Lbs (kg)**|
|46.09|44.45|42.77|36.35|26.31|20.92|19.30|2.69|17.74|16.76|3.31|235 (107)|290 (132)|
|(1170.7)|(1129.0)|(1086.4)|(923.3)|(668.3)|(531.4)|(490.2)|(68.3)|(450.6)|(425.7)|(84.1)|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-226**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size C—UL Type 3R**
||||**H3**<br>**H4**<br>**H5**<br>**W**<br>**W1**<br>**W2**<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)<br>H<br>W2<br>W1<br>W3<br>D2<br>D1<br>W<br>D<br>H|||W<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|W<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|W<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|W<br>0.44 (11.2)<br>Mounting Holes<br>(4 Places)|
|---|---|---|---|---|---|---|---|---|---|
||||W2<br>W1<br>W|||W2|D|||
|H1|H3<br>H2|||H3<br>H2<br>5|||||H|
|||||||||||
|||||||||||
|||||||||||
||**H1**<br>**H2**|||||||||
|||||||||||
|||||**W3**<br>**D**<br>||||||
|8.09<br>1475.5)<br>56.45<br>(1433.8)<br>54.77<br>(1391.2)|||48.35<br>(1228.1)<br>78.09<br>(1983.5)<br>77.64<br>(1972.1)<br>37.73<br>(958.3)<br>30.92<br>(785.4)<br>29.30<br>(744.2|)<br>3.34<br>(84.8)<br>17.74<br>(450.6)<br><br>(||16.77<br>426.0)<br>3.31<br>(84.1)<br>370 (168)<br>485 (220)||||
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-227**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size D—UL Type 3R**
|**D—UL Type 3R**||||||
|---|---|---|---|---|---|
||**D**<br>**D1**<br>**Approximate**<br>**Shipping Weight**<br>**Lbs (kg)**<br>H1<br>D1<br>D|||||
|Ø0.44 (11.2)<br>Mounting Holes<br>(two places)<br>W1<br>W<br>W2||||||
|||||||
|||||H1||
|||||||
|||||||
||D|||||
|||||||
|||||||
|||||||
|||||||
|**W**<br>**W1**<br>**W2**|**D**|||||
|)<br>30.92<br>(784.4)<br>37.73<br>(958.3)<br>29.30<br>(744.2)|16.76<br>(424.7)|17.74<br>(450.6)<br>1000 (454)||||
|r stands.||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-228**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size F**
**==> picture [326 x 283] intentionally omitted <==**
**----- Start of picture text -----**<br>
W D<br>H1 H<br>W1<br>D1<br>**----- End of picture text -----**<br>
**2**
**==> picture [154 x 84] intentionally omitted <==**
|||||||**Approximate**|**Approximate**|
|---|---|---|---|---|---|---|---|
|||||||**Weight**|**Shipping Weight**|
|**H**|**H1**|**W**|**W1**|**D**|**D1**|**Lbs (kg)**|**Lbs (kg)**|
|93.58|69.51|60.00|48.00|37.50|26.00|1700 (771)|1850 (839)|
|(2376.9)|(1765.60)|(1524.0)|(1219.2)|(952.5)|(660.4)|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-229**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size 7**
**2**
**==> picture [386 x 573] intentionally omitted <==**
**----- Start of picture text -----**<br>
4.79<br>Exhaust For (121.7)<br>Air Cable Entry<br>20.00<br>(508.0) 15.00<br>(381.0)<br>2.00<br>Hinged Side (50.8)<br>26.25 Door Clearance 10.00<br>(666.8) at 90° (254.0)<br>Top View<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>Keypad<br>Flanged Disconnect Supplied<br>with Circuit Breaker<br>When Specified<br>Operator Elements<br>When Specified, Mounted<br>on These Panels<br>Door Handle<br>(key-lock optional)<br>93.92<br>(2385.6) (2286.0)90.00 (2143.0)84.37 Intake Ventilating Slots<br>(Filtered on NEMA 12)<br>Quarter Turn Latch<br>(two places)<br>15.50 30.00<br>(393.7) (762.0)<br>21.50 Front View<br>(546.1)<br>Side View<br>Mounting Holes.56 (14.2) Dia. (88.9)3.50 Opening forBottom Cable Entry<br>(4 Places)<br>8.50<br>18.75 (215.9)<br>(476.3)<br>5.75 8.00<br>(146.1) (203.2)<br>1.75 (44.5) Typ.<br>Construction: UL Type 1 Oversize 24.45 (621.0)<br>Finish: Enclosure – ANSI 61 Gray (Light) 28.05 (712.5)<br>Bottom View<br>**----- End of picture text -----**<br>
**Approximate Shipping Weight Lbs (kg)** 1000 (454)
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-230**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size 8**
**==> picture [504 x 567] intentionally omitted <==**
**----- Start of picture text -----**<br>
31.00<br>1.25 (787.4)<br>(31.8)<br>8.25<br>(209.6)<br>Opening for Top Cable Entry<br>(2 Places)<br>Top View<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>Keypad<br>Flanged Disconnect Supplied<br>with Circuit Breaker When Specified<br>Operator Elements When Specified,<br>Mounted on These Panels<br>Door Handle<br>(key-lock optional)<br>93.50<br>(2374.9) 90.00 84.37<br>(2286.0) (2143.0)<br>Intake Ventilating Slots<br>(Filtered on NEMA 12)<br>Quarter Turn Latch<br>(2 Places)<br>24.00 (609.6) 21.45 (544.8) 21.31 (541.3)<br>48.00 (1219.2)<br>25.14 (639)<br>Front View<br>Side View .56 (14.2) Dia. 9.50<br>Mounting Holes (241.3)<br>(4 Places)<br>Opening for<br>Bottom Cable Entry<br>22.47 12.50<br>(570.74) (317.5)<br>7.73<br>5.48 (196.34)<br>(139.19)<br>3.01 (76.45) Approximate<br>Construction: UL Type 1 Oversize Shipping Weight<br>Finish: Enclosure – ANSI 61 Gray (Light) 37.47 (951.74) Lbs (kg)<br>45.22 (1148.59)<br>Bottom View 1400 (636)<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-231**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
**==> picture [548 x 614] intentionally omitted <==**
**----- Start of picture text -----**<br>
Enclosure Size 9<br>2<br>43.50 (1104.9)<br>1.50 (38.1)<br>2 8.75<br>(222.3)<br>2 (189.5 x 381.0)7.46 x 15.00<br>Access in Top<br>2 (two places)<br>2<br>90 Max. 90 Max.<br>Door Door<br>2 (694.9)27.36 Opening Opening 27.06<br>(687.3)<br>2 29.05<br>(737.9)<br>2 Top View<br>2 4.00 (101.6) Minimum<br>Free Air Space Required<br>2<br>2<br>2<br>2<br>2<br>93.50<br>(2374.9) Drive<br>2 Circuit Breaker<br>2<br>90.00<br>2 (2286.0)<br>Door Handle<br>(key-lock optional)<br>2<br>Access<br>2 Plate<br>(4 places)<br>2<br>2<br>24.00 (609.6) 60.00 (1524.0)<br>2 25.14 (638.6) Front View 8.50 x 12.00 (215.9 x 304.8)<br>Side View 32.72 (831.1) Bottom Access<br>2 ø0.56 (ø14.2) Dia.<br>Mounting Hole<br>(five places)<br>2 25.00<br>(635.0)<br>18.84<br>2 (478.5)<br>Finish: Enclosure—ANSI 61 Gray (light) 8.20 11.93<br>(303.0)<br>2 Material: Enclosure and Backplate— 12 ga. = 0.1046 Cold Rolled Steel (208.3)<br>2.00 (50.8) 22.90 (581.7)<br>2 46.30 (1176.0) Approximate<br>54.90 (1394.5) Shipping Weight<br>2 Bottom View Lbs (kg)<br>1800 (817)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-232**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Enclosed 18-Pulse Drives**
## **Contents**
|**Contents**||**2**|
|---|---|---|
|**_Description_**|**_Page_**||
|Enclosed Passive Filtered Drives . . . . . . . . . . . . . .|**V6-T2-200**|**2**|
|Enclosed 18-Pulse Drives|||
|Application Description . . . . . . . . . . . . . . . . . . .|**V6-T2-234**|**2**|
|Features and Benefits . . . . . . . . . . . . . . . . . . .<br>Catalog Number Selection . . . . . . . . . . . . . . . .|**V6-T2-239**<br>**V6-T2-240**|**2**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .<br>Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-241**<br>**V6-T2-249**|**2**|
|Technical Data and Specifications . . . . . . . . . .<br>Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-255**<br>**V6-T2-257**|**2**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-258**|**2**|
## **Enclosed 18-Pulse Drives**
## **Product Description**
Eaton’s enclosed 18-pulse clean power drives use advanced 18-pulse clean power technology that significantly reduces line harmonics at the drive input terminals, resulting in one of the purest sinusoidal waveforms available.
The enclosed 18-pulse drive also delivers True Power Factor—in addition to reducing harmonic distortion, the enclosed 18-pulse drive prevents upstream transformer overheating and overloading of breakers and feeders, enabling the application of adjustable frequency drives on generators and other high impedance power systems.
All 9000X Series drives are constant torque rated and rated for either high overload (IH) or low overload (IL). IH indicates 150% overload capacity for 1 minute out of 10 minutes. IL indicates 110% overload capacity for 1 minute out of 10 minutes.
## **Enclosed 18-Pulse Drive Products**
- **Enclosed 18-Pulse Drive** ● **Custom Engineered** — **Products** for those applications with ● **Standard Enclosed** — more unique or complex requirements, these are
- covers a wide range of the individually engineered
- most commonly ordered to the customer’s needs.
- options. Pre-engineering eliminates the lead time _Contact your local sales office for assistance in_
- normally associated with _pricing and lead time._
- customer specific options. Available configurations are listed on **Pages V6-T2-240** and **V6-T2-249** to **V6-T2-254.**
- **Modified Standard Enclosed** —applies to specific customer requirements that vary from the Standard Enclosed offering, such as the need for an additional indicating light or minor modifications to drawings. _Contact your local sales office for assistance in pricing and lead time._
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-233**
Adjustable Frequency Drives
Low Harmonic Drives
## 2.8
## **Application Description**
Designed to exceed the IEEE[®] the water, wastewater, 519-1992 requirements for HVAC, industrial and process **2** harmonic distortion, the industries where harmonics enclosed 18-pulse drive is the are a concern. **2** clear choice for applications in
## **What Are Harmonics?**
## _**Take a perfect wave with a fundamental frequency of 60 Hz, which is close to what is supplied by the power company.**_
## **Perfect Wave**
**==> picture [178 x 116] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volts<br>(v)<br>Time<br>(t)<br>**----- End of picture text -----**<br>
**==> picture [75 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
f(x) = sin(x)<br>**----- End of picture text -----**<br>
_**Add a second wave that is five times the fundamental frequency— 300 Hz (typical of frequency added to the line by a fluorescent light).**_
## **Second Wave**
**==> picture [230 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volts<br>(v)<br>f(x) = [ sin(5x)]<br>5<br>Time<br>(t)<br>**----- End of picture text -----**<br>
_**Combine the two waves. The result is a 60 Hz supply rich in fifth harmonics.**_
## **Resulting Supply**
**==> picture [230 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
Volts<br>(v)<br> sin(5x)<br>f(x) = sin(x) +<br>5<br>Time<br>(t)<br>**----- End of picture text -----**<br>
## **What Causes Harmonics?**
Harmonics are the result of nonlinear loads that convert AC line voltage to DC. Examples of equipment that are non-linear loads are listed below:
- AC variable frequency drives
- DC drives
- Fluorescence lighting, computers, UPS systems
- Industrial washing machines, punch presses, welders, etc.
## _**How Can Harmonics Due to VFDs Be Diminished?**_
By purchasing Eaton’s enclosed 18-pulse drive that is guaranteed to meet IEEE Std. 519-1992 Harmonic Distortion Limits.
## _**What Are Linear Loads?**_
Linear loads are primarily devices that run across the line and do not add
harmonics. Motors are prime examples. The downside to having large motor linear loads is that they draw more energy than a VFD, because of their inability to control motor speed. In most applications, there is a turn down valve used with the motor that will reduce the flow of the material, without significantly reducing the load to the motor. While this provides some measure of speed control, it is extremely inefficient.
## **Why Be Concerned About Harmonics?**
1. _**Installation and utility costs increase.**_ Harmonics cause damage to transformers and lower efficiencies due to the IR loss. These losses can become significant and can have a dramatic effect on the HVAC systems that are controlling the temperatures of the building where the transformer and drive equipment reside.
2. _**Downtime and loss of productivity.**_ Telephones and data transmissions links may not be guaranteed to work on the same power grids polluted with harmonics.
3. _**Downtime and nuisance trips of drives and other equipment.**_ Emergency generators have up to three times the impedance that is found in a conventional utility source. Thus the harmonic voltage distortion can be up to three times as large, causing risk of operation problems.
4. _**Larger motors must be**_
_**used.**_ Motors running across the line that are connected on polluted power distribution grids can overheat or operate at lower efficiency due to harmonics.
5. _**Higher installation costs.**_ Transformers and power equipment must be oversized to accommodate the loss of efficiencies. This is due to the harmonic currents circulating through the distribution without performing useful work.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-234**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **How Does a VFD Convert Three-Phase AC to a Variable Output Voltage and Frequency?**
The six-pulse VFD: The majority of all conventional drives that are built consist of a six-pulse configuration. The figure below represents a six-diode rectifier design that converts three-phase utility power to DC. The inverter section uses IGBTs to convert DC power to a simulated AC sine wave that can vary in frequency from 0–320 Hz.
The six-pulse VFD drive creates harmonic current distortion. The harmonic current that is created is energy that can not be used by customers and causes external heat and losses to all components including other drives that are on the same power distribution. See the curve below showing a 500 hp drive with 167A of damaging harmonic current.
## **Six-Diode Rectifier Design**
**==> picture [240 x 146] intentionally omitted <==**
**----- Start of picture text -----**<br>
Six-Pulse Diode Inverter Section<br>Bridge Rectifier<br>Converter Section (+) DC<br>L2A<br>L1A AC<br>Motor<br>L3A<br>(–) DC<br>Dynamic Braking Output Transistors<br>Bus Transistor IGBT Section<br>Capacitors<br>**----- End of picture text -----**<br>
## **Guidelines of Meeting IEEE Std. 519-1992 Harmonic Distortion Limits**
The IEEE 519-1992 Specification is a standard that provides guidelines for commercial and industrial
users that are implementing medium and low voltage equipment.
## **Maximum Harmonic Current Distortion in % of the Fundamental (120V through 69,000V)**
||**Harmonic**|**Order**|**(Odd**|**Harmonics)**|**Harmonics)**||||||
|---|---|---|---|---|---|---|---|---|---|---|
|**Isc/IL**|**h<11**|**11<**<br>~~**h**~~**<17**||**17<**<br>~~**h**~~**<23**||**23<**<br>~~**h**~~**<35**||**35<**<br>**h**||**TDD**|
|<20|4.0|2.0||1.5||0.6||0.3||5.0|
|20<50|7.0|3.5||2.5||1.0||0.5||8.0|
|50<100<br>100<1000|10.0<br>12.0|4.5<br>5.5||4.0<br>5.0||1.5<br>2.0||0.7<br>1.0||12.0<br>15.0|
|>1000|15.0|7.0||6.0||2.5||1.4||20.0|
_**The ratio Isc/IL is the ratio of the short-circuit current available at the point of common coupling (PCC), to the maximum fundamental load current. Consequently, as the size of the user load decreases with respect to the size of the system, the percentage of harmonic current that the user is allowed to inject into the utility system increases.**_
## _**Notes**_
TDD = Total demand distortion is the harmonic current distortion in percent of the maximum demand load current (15 or 30 minute demand).
ISC = Maximum short-circuit current at the PCC not counting motor contribution.
IL = Maximum demand load current for all of the connected loads (fundamental frequency component) at the PCC. All of the limits are measured at a point of common coupling.
**2**
## **500 hp Six-Pulse Nonproductive Harmonic Current**
**==> picture [233 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current<br>Amps<br>1000<br>500<br>0<br>–500<br>–1000<br>0.100 0.10625 0.1125 0.11875 0.125<br>Time in Seconds<br>**----- End of picture text -----**<br>
## **500 hp Six-Pulse Nonproductive Harmonic Current**
**Six-Pulse Circuit**
|Current harmonics|||
|---|---|---|
|I1= 100%|I11= 6.10%|I19= 1.77%|
|I5= 22.5%|I13= 4.06%|I23= 1.12%|
|I7= 9.38%|I17= 2.26%|I25= 0.86%|
|Power = 500 hp|||
|Harmonic current = 167 amps|||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-235**
Adjustable Frequency Drives
2.8
## Low Harmonic Drives
## **One-Line Diagram for Harmonic Analysis**
**==> picture [498 x 262] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>____Volts ____Volts ____Volts ____Volts Source A<br>2 PCC<br>Utility Side<br>2 AC AC<br>Motor Motor<br>2<br>2<br>2 TransformerUtility Side TransformerCustomer<br>2 ____Volts ____kVA ____Volts ____kVA MotorAC MotorAC<br>____Isc ____Isc<br>2 ____Impedance ____Impedance<br>2<br>Customer AC AC<br>2 Generator Motor Motor<br>____Volts Generator<br>2 ____kVA Set | |<br>____Isc<br>____Impedance<br>2<br>Total Linear Motor Loads ____AMPS<br>Source B Total Non-Linear Drive Loads ____AMPS<br>**----- End of picture text -----**<br>
_**The best way to estimate AFD harmonic contribution to an electrical system is to perform a harmonic analysis based on known system characteristics. The one-line in this figure would provide the data to complete the calculations.**_
## _**Terms**_
- PCC (Point of Common Coupling) is defined as the electrical connecting point between the utility and multiple customers per the specifications in IEEE 519
- POA (Point of Analysis) is defined as where the harmonic calculations are taken
An oscilloscope can make all measurements at the PCC or POA do an on-site harmonic evaluation.
## **Harmonic Reduction Methods to Meet IEEE 519**
## _**1. Line Reactor**_
A line reactor is a three-phase series inductance on the line side of an AFD. If a line reactor is applied on all AFDs, it is possible to meet IEEE guidelines where 10–25% of system loads are AFDs, depending on the stiffness of the line and the value of line reactance. Line reactors are available in various values of impedance, most typically 1–1.5%, 3% and 5%.
**Line Reactor**
~~AFD~~ Motor = ~~r~~ )
## _**Advantages**_
## _**Disadvantages**_
- Low cost
- May not reduce harmonic levels to below IEEE 5191992 guidelines
- Can provide moderate reduction in voltage and current harmonics
- Voltage drop due to IR loss
- Available in various values of impedance
- Provides increased input protection for AFD and its semiconductors from line transients
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-236**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## _**2. 12-Pulse Converters**_
A 12-pulse converter incorporates two separate AFD input semiconductor bridges, which are fed from 30º phase shifted power sources with identical impedance. The sources may be two isolation transformers, where one is a delta/wye design (which provides the phase shift)
and the second a delta/delta design (which does not phase shift). The 12-pulse arrangement allows the harmonics from the first converter to cancel the harmonics of the second. Up to approximately 85% reduction of harmonic current and voltage distortion may be achieved (over standard
six-pulse converter). This permits a facility to use a larger percentage of AFD loads under IEEE 519-1992 guidelines than allowable using line reactors or DC chokes. A harmonic analysis is required to guarantee compliance with guidelines.
**2**
## **Basic 12-Pulse Rectifier with “Phase Shifting” Transformer**
**==> picture [431 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
12-Pulse 12-Pulse Diode Inverter Section<br>Phase-Shifting Bridge Rectifier<br>Transformer Converter Section<br>(+) DC<br>L1A<br>L2A<br>L3A<br>AC<br>Motor<br>L1B<br>L2B<br>L3B<br>(-) DC<br>12-Pulse Diode Dynamic Braking Output Transistors<br>Bridge Rectifier Transistor IGBT Section<br>Converter Section Bus<br>Capacitors<br>**----- End of picture text -----**<br>
## **500 hp 480V Drive with 12-Pulse Rectifier**
**==> picture [233 x 148] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current<br>Amps<br>1000<br>500<br>0<br>–500<br>–1000<br>0.126 0.13225 0.1385 0.14475 0.151<br>Time in Seconds<br>**----- End of picture text -----**<br>
## **500 hp 480V Drive with 12-Pulse Rectifier**
## **12-Pulse Circuit**
|**12-Pulse Circuit**|||
|---|---|---|
|Current harmonics|||
|I1= 100%<br>I5= 1.25%<br>I7= 0.48%|I11= 4.19%<br>I13= 2.95%<br>I17= 0.21%|I19= 0.06%<br>I23= 0.87%<br>I25= 0.73%|
|Power = 500 hp|||
|Hc= 66.2 amps|||
## _**Advantages Disadvantages**_
- Moderate cost, although ● Impedance matching of significantly more than phase shifted sources is reactors or chokes critical to performance
- Substantial reduction (up ● Transformers often require to approx. 85%) in voltage separate mounting or and current harmonics larger AFD enclosures
- Provides increased input ● May not reduce protection for AFD and its distribution harmonic levels semiconductors from line to below transients IEEE 519-1992 guidelines
- Cannot retrofit for most AFDs
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-237**
Adjustable Frequency Drives
Low Harmonic Drives
## 2.8
## _**3. Clean Power Drives**_
When the total load is of nonlinear, the greatest harmonic **2** mitigation is required. Under these conditions, the currents **2** drawn from the supply need to be sinusoidal and “clean” **2** such that system interference and additional **2** losses are negligible. Eaton’s enclosed 18-pulse clean power drive uses a phase- **2** shifting auto-transformer with delta-connected winding. **2** Three of the output phases
are advanced and three are retarded. The remaining three phases of this nine-phase supply are in phase with the incoming line. This results in nine separate phases. In this type of configuration, the total required kVA rating of the transformer is only 48% of a drive rate isolation transformer. A traditional isolated transformer system, with multipulse windings, would require the full kVA
rating to be supported, which is more common in an MV step-down transformer.
The integrated 18-pulse clean power drive, with near sine wave input current and low harmonics will meet the requirements of IEEE 519-1992 under all practical operating conditions. The comparisons with six-pulse and 12-pulse systems are shown, see **Pages V6-T2-235** , **V6-T2-237** and **V6-T2-238** .
## **Basic 18-Pulse Rectifier with Phase Shifting Transformer**
**==> picture [481 x 191] intentionally omitted <==**
**----- Start of picture text -----**<br>
18-Pulse SCR Inverter Section<br>Bridge Rectifier Pre-charge<br>Converter Section Circuit<br>(+) DC<br>A 1<br>2<br>1 3<br>9 2<br>1 8 3 4 AC<br>2 N 5 Motor<br>3 7 4 6<br>C 7<br>6 5 8<br>9<br>(–) DC<br>18-Pulse Diode Rectifiers Dynamic Braking Output Transistors<br>Phase-Shifting Transistor IGBT Section<br>3-Phase Auto-Transformer<br>Bus<br>AC Input<br>Capacitors<br>**----- End of picture text -----**<br>
## **500 hp 480V Drive with 18-Pulse Rectifiers**
**==> picture [233 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current<br>Amps<br>1000<br>500<br>0<br>–500<br>–1000<br>0.126 0.13225 0.1385 0.14475 0.151<br>Time in Seconds<br>**----- End of picture text -----**<br>
## **500 hp 480V Drive with 18-Pulse Rectifiers**
## **18-Pulse Clean Power**
|Current harmonics|||
|---|---|---|
|I1= 100%<br>I5= 0.16%|I11= 0.24%<br>I13= 0.10%|I19= 1.00%<br>I23= 0.01%|
|I7= 0.03%|I17= 0.86%|I25= 0.01%|
|Power = 500 hp|||
|Hc= 24 amps|||
|**_Advantages_**<br>●Virtually guarantees|**_Disadvantages_**<br>●Not as cost-effective as||
|compliance with<br>IEEE 519-1992<br>●Provides increased input<br>protection for AFD and its||some other methods at<br>small (<50) horsepower|
|semiconductors from line<br>transients|||
- Up to four times the harmonic reduction of 12-pulse methods
- ● Smaller transformer than isolation transformer used in 12-pulse converter
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-238**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Features and Benefits**
Enclosed 18-pulse clean power drive features include:
- Space optimized enclosure
- Simple layout for power options
- Type 1, NEMA 12 with gaskets and filters, Type 3R
- Input voltage: 480V, 208V, 575V
- Complete range of control, network and power options
- Horsepower range:
- 480V, 25–800 hp (consult factory for larger sizes)
- 208/230V, 25–200 hp
- 575V, 25–800 hp (consult factory for larger sizes)
- Over 15 years of 18-pulse clean power experience
- 65 kAIC Standard at 480V and 208V
- 100 kAIC optional
## **Standards and Certifications**
UL 508C tested, listed and approved.
**2**
## **Product Identification**
**==> picture [138 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type 1, 25–150 hp (30 x 90 x 21.50)<br>**----- End of picture text -----**<br>
**==> picture [381 x 308] intentionally omitted <==**
**----- Start of picture text -----**<br>
SVX9000 Drive<br>Bypass Starter Assembly<br>a 4 (option)<br>Motor Circuit Protector<br>HO m f (standard with bypass options)<br>Door Mounted Keypad<br>Pre-Charge Input Contactor<br>18-Pulse Diode Rectifier Input Line Fuses<br>her<br>mi i,<br>Input Choke<br>18-Pulse Auto-Transformer<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-239**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Catalog Number Selection**
**==> picture [98 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Enclosed 18-Pulse Drive<br>**----- End of picture text -----**<br>
**==> picture [233 x 304] intentionally omitted <==**
**----- Start of picture text -----**<br>
2<br>C P X 1 0 0 1 4 A A<br>2<br>Product Family<br>2 CPX = Clean power 18-pulseenclosed drives<br>2 Horsepower Rating<br>025 = 25 hp 100 = 100 hp 350 = 350 hp<br>2 030 = 30 hp 125 = 125 hp 400 = 400 hp<br>040 = 40 hp 150 = 150 hp 500 = 500 hp<br>050 = 50 hp 200 = 200 hp 600 = 600 hp<br>2 060 = 60 hp 250 = 250 hp 700 = 700 hp<br>075 = 75 hp 300 = 300 hp 800 = 800 hp<br>2<br>Enclosure Rating<br>1 = Type 1<br>2 3 = Type 3R<br>6 = Type 12 filtered<br>2<br>Voltage Rating<br>2 24 = 230V (208–240V) = 480V<br>5 = 575V (575–600V)<br>2<br>Application—Torque/Braking [1]<br>2 A = IL/no brake chopper<br>B = IL/internal brake chopper<br>D = IH/no brake chopper<br>2 E = IH/internal brake chopper<br>2 Enclosed Style<br>A = Enclosed drive<br>**----- End of picture text -----**<br>
|||Build options alphabetically and numerically.|Build options alphabetically and numerically.|Build options alphabetically and numerically.|Build options alphabetically and numerically.|Build options alphabetically and numerically.|Build options alphabetically and numerically.|
|---|---|---|---|---|---|---|---|
|||**Enclosed Options**234|||||**Type**|
|**K1**<br>**K2**<br>**K3**<br>**K4**<br>**K5**<br>**K6**<br>**KF**<br>**KO**|Door-mounted speed potentiometer5<br>Door-mounted speed potentiometer with HOA selector switch5<br>3–15 psig follower<br>HAND/OFF/AUTO switch 0.87-inch (22 mm)<br>MANUAL/AUTO reference switch 0.87-inch (22 mm)<br>START/STOP pushbuttons 0.87-inch (22 mm)<br>Bypass test switch for RA and RB<br>Standard elapsed time meter||||||Control<br>Control<br>Control<br>Control<br>Control<br>Control<br>Addl. bypass<br>Control|
|**L1**<br>**L2**<br>**LE**|Power, RUN and fault pilot lights<br>Bypass pilot lights for RA, RB, bypass options<br>Red RUN light||||||Light<br>Addl. bypass<br>Light|
|**P1**<br>**P8**<br>**PE**<br>**PF**<br>**PG**<br>**PH**<br>**PI**<br>**PN**|Input disconnect<br>Surge protective device<br>Output contactor<br>Output filter<br>MotoRx (up to 600 ft [182.9m]) 1000 V/μS DV/DT filter<br>Single overload relay<br>Dual overload relays<br>Dual overloads for bypass||||||Input<br>Input<br>Output<br>Output<br>Output<br>Output<br>Output<br>Addl. bypass|
|**RA**<br>**RB**<br>**RC**<br>**RD**<br>**RG**|Manual HOA bypass controller<br>Manual IOB bypass controller<br>Auto transfer HOA bypass controller<br>Auto transfer IOB bypass controller<br>Reduced voltage starter for bypass||||||Bypass<br>Bypass<br>Bypass<br>Bypass<br>Bypass|
|**S7**<br>**S8**<br>**S9**|10.00-inch (254.0 mm) expansion<br>20.00-inch (508.0 mm) expansion<br>Space heater||||||Enclosure<br>Enclosure<br>Enclosure|
|||||||||
||||||**Communication Options**6|||
||||**C2**= Modbus®<br>**C3**= PROFIBUS®DP<br>**C4**= LonWorks®<br>**C5**= PROFIBUS DP (D<br>**C6**= CANopen (slave)<br>**C7**= DeviceNet™<br>**C8**= Modbus (D9 Typ||9 connector)<br>e connector)|**CA**= Johnson Controls N2<br>**CI**= Modbus TCP<br>**CJ**= BACnet<br>**CQ**= EtherNet/IP<br>**D3**= RS-232 with D9 connection||
|||||||||
||||||**Control Options**|||
||||**B1**= 6 DI, 1 ext +24 V<br>**B2**= 1 RO (NC/NO), 1<br>**B4**= 1 AI (mA isolated<br>**B5**= 3 RO (NO)<br>**B8**= 1 ext +24 Vdc/ex<br>**B9**= 1 RO (NO), 5 DI 4||dc/ext +24 Vdc<br>RO (NO), 1 therm<br>), 2 AO (mA isolated), 1 ext +24 Vdc/EXT +24 Vdc<br>t +24 Vdc, 3 Pt100<br>2–240 Vac input|||
|||||||||
||||**Engineered Options**|||||
||||**HT**<br>**VB**|High temperature rating for 50°C (FR10 and above)7<br>Varnished boards||||
## _**Notes**_
- 1 Brake chopper is standard in drives up to 30 hp IH or 40 hp IL at 480V. It is optional in larger drives.
> 2 Local/remote keypad is included as the standard control panel.
- 3 Some options are voltage and/or horsepower specific. Consult your Eaton representative for details.
- 4 See **Pages V6-T2-251** and **V6-T2-252** for complete descriptions.
- 5 Includes local/remote speed reference switch.
- 6 See **Pages V6-T2-249** and **V6-T2-250** for complete descriptions.
- 7 Consult Eaton for availability.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-240**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Product Selection**
## _**When Ordering**_
- Select a base catalog ● The enclosed 18-pulse number that meets the drive product uses the application requirements— term High Overload (IH) in nominal horsepower, place of the term Constant voltage and enclosure Torque (CT). Likewise, Low rating. (The enclosed Overload (IL) is used in drive’s continuous output place of the term Variable amp rating should be equal Torque (VT). The new to or greater than the terms are a more precise motor’s full load amp description of the rating. rating.) The base-enclosed The older terms included package includes a ambient temperature standard drive, doorratings in addition to mounted alphanumeric overload ratings. In order to panel and enclosure. minimize enclosure size and offer the highest ambient temperature
- rating, overload and ● If dynamic brake chopper **2** temperature ratings are or control/communication now treated separately. option is desired, change **2** Ambient temperature the appropriate code in the ratings are shown in the base catalog number. **2** table below. Consult the ● All of the programming is
- factory for 50°C ratings of FR10 and above. exactly the same as the **2** standard SVX9000 drive.
|**Ambient Temperature**<br>**Ratings**<br>**Frame**<br>**Size**<br>**IH**<br>**IL**<br>FR4–FR9<br>50°C<br>50°C|●Select enclosed options.<br>Add the codes as suffixes<br>to the base catalog number<br>in alphabetical and numeric<br>order.|
|---|---|
|FR10 and above<br>40°C<br>40°C||
## **208/230V Drives**
|**Enclosed 18-Pulse**|**Enclosed 18-Pulse Base Drive Type 1**<br>**Enclosed 18-Pulse**|**Enclosed 18-Pulse Base Drive Type 1**<br>**Enclosed 18-Pulse**|**Enclosed 18-Pulse Base Drive Type 1**<br>**Enclosed 18-Pulse**|||
|---|---|---|---|---|---|
|**Drive**|**Enclosure**||**Current**|**Chassis**|**Base Catalog**|
||**Size**1|**hp**2|**(A)**|**Frame**|**Number**3|
||**Low Overload Drive**|||||
||7|25|75|FR7|**CPX02512AA**|
|||30|88|FR7|**CPX03012AA**|
|||40|114|FR7|**CPX04012AA**|
|||50|140|FR8|**CPX05012AA**|
|||60|170|FR8|**CPX06012AA**|
||.|8|75<br>100|205<br>300|FR8<br>FR9|**CPX07512AA**<br>**CPX10012AA**|
||9|125|340|FR8T|**CPX12512AA**|
|||150|410|FR8T|**CPX15012AA**|
||10|200|522|FR9T|**CPX20012AA**|
||**High Overload Drive**|||||
||7|25|75|FR7|**CPX02512DA**|
|||30|88|FR7|**CPX03012DA**|
|||40|114|FR8|**CPX04012DA**|
|||50|140|FR8|**CPX05012DA**|
|||60|170|FR8|**CPX06012DA**|
||8|75|205|FR9|**CPX07512DA**|
||9|100|300|FR8T|**CPX10012DA**|
|||125|340|FR8T|**CPX12512DA**|
||10|150|410|FR9T|**CPX15012DA**|
|||200|522|FR9T|**CPX20012DA**|
## _**Notes**_
- 1 See enclosure dimensions beginning on **Page V6-T2-258** .
- 2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
- 3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-241**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
**2**
## **Enclosed 18-Pulse Drive**
## **Enclosed 18-Pulse Base Drive NEMA 12 Filtered**
|**Enclosure**||**Current**|**Chassis**|**Base Catalog**|
|---|---|---|---|---|
|**Size**1<br>**Low Overload Drive**|**hp**2<br>**Low Overload Drive**|**(A)**|**Frame**|**Number**3|
|7|25|75|FR7|**CPX02562AA**|
||30|88|FR7|**CPX03062AA**|
||40|114|FR7|**CPX04062AA**|
||50|140|FR8|**CPX05062AA**|
||60|170|FR8|**CPX06062AA**|
||75|205|FR8|**CPX07562AA**|
|8|100|300|FR9|**CPX10062AA**|
|9|125|340|FR8T|**CPX12562AA**|
||150|410|FR8T|**CPX15052AA**|
|10|200|522|FR9T|**CPX20062AA**|
|**High Overload Drive**<br>7|**High Overload Drive**<br>25|75|FR7|**CPX02562DA**|
||30|88|FR7|**CPX03062DA**|
||40|114|FR8|**CPX04062DA**|
||50|140|FR8|**CPX05062DA**|
||60|170|FR8|**CPX06062DA**|
|8|75|205|FR9|**CPX07562DA**|
|9|100<br>125|300<br>340|FR8T<br>FR8T|**CPX10062DA**<br>**CPX12562DA**|
|10|150|410|FR9T|**CPX15062DA**|
||200|522|FR9T|**CPX20062DA**|
## **Enclosed 18-Pulse Base Drive Type 3R**[4]
|**Enclosure**||**Current**|**Chassis**|**Base Catalog**|
|---|---|---|---|---|
|**Size**1|**hp**2|**(A)**|**Frame**|**Number**3|
|**Low Overload Drive**|**Low Overload Drive**||||
|7|25|75|FR7|**CPX02532AA**|
||30<br>40|88<br>114|FR7<br>FR7|**CPX03032AA**<br>**CPX04032AA**|
||50|140|FR8|**CPX05032AA**|
||60|170|FR8|**CPX06032AA**|
||75|205|FR8|**CPX07532AA**|
|8|100|300|FR9|**CPX10032AA**|
|9|125|340|FR8T|**CPX12532AA**|
|**High Overload Drive**<br>7|**High Overload Drive**<br>25|75|FR7|**CPX02532DA**|
||30|88|FR7|**CPX03032DA**|
||40|114|FR8|**CPX04032DA**|
||50|140|FR8|**CPX05032DA**|
|8|60<br>75|170<br>205|FR8<br>FR9|**CPX06032DA**<br>**CPX07532DA**|
|9|100|300|FR8T|**CPX10032DA**|
## _**Notes**_
> 1 See enclosure dimensions beginning on **Page V6-T2-258** .
2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
- 3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
- 4 All Type 3R drives use the Size F enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-242**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **480V Drives**
## **Enclosed 18-Pulse Drive**
## **Enclosed 18-Pulse Base Drive Type 1**
|**Enclosure**||**Current**|**Chassis**|**Base Catalog**|
|---|---|---|---|---|
|**Size**1|**hp**2|**(A)**|**Frame**|**Number**3|
|**Low Overload Drive**|**Low Overload Drive**||||
|7|25|38|FR6|**CPX02514BA**|
||30|46|FR6|**CPX03014BA**|
||40|61|FR6|**CPX04014BA**|
||50|72|FR7|**CPX05014AA**|
||60|87|FR7|**CPX06014AA**|
||75|105|FR7|**CPX07514AA**|
||100|140|FR8|**CPX10014AA**|
||125|170|FR8|**CPX12514AA**|
||150|205|FR8|**CPX15014AA**|
|8|200|261|FR9|**CPX20014AA**|
||250|300|FR9|**CPX25014AA**|
|9|300|385|FR10|**CPX30014AA**|
||350|460|FR10|**CPX35014AA**|
||400|520|FR10|**CPX40014AA**|
|10|500|590|FR11|**CPX50014AA**|
||550|650|FR11|**CPX55014AA**|
||600|730|FR11|**CPX60014AA**|
|11|650|820|FR11|**CPX65014AA**|
||700|920|FR12|**CPX70014AA**|
||800|1030|FR12|**CPX80014AA**|
|**High Overload Drive**|**High Overload Drive**||||
|7|25|38|FR6|**CPX02514EA**|
||30|46|FR6|**CPX03014EA**|
||40|61|FR7|**CPX04014DA**|
||50|72|FR7|**CPX05014DA**|
||60|87|FR7|**CPX06014DA**|
||75|105|FR8|**CPX07514DA**|
||100|140|FR8|**CPX10014DA**|
||125|170|FR8|**CPX12514DA**|
|8|150|205|FR9|**CPX15014DA**|
||200|245|FR9|**CPX20014DA**|
|9|250|300|FR10|**CPX25014DA**|
||300|385|FR10|**CPX30014DA**|
||350|460|FR10|**CPX35014DA**|
|10|400|520|FR11|**CPX40014DA**|
||500|590|FR11|**CPX50014DA**|
||550|650|FR11|**CPX55014DA**|
|11|600|720|FR12|**CPX60014DA**|
||650|820|FR12|**CPX65014DA**|
||700|840|FR12|**CPX70014DA**|
**2**
## _**Notes**_
- 1 See enclosure dimensions beginning on **Page V6-T2-258** .
- 2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
- 3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-243**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
**2**
## **Enclosed 18-Pulse Drive**
## **Enclosed 18-Pulse Base Drive NEMA 12 Filtered**
**==> picture [255 x 528] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||
|---|---|---|---|---|---|---|---|
|Enclosure|Current|Chassis|Base Catalog|
|Size|[1]|hp|[2]|(A)|Frame|Number|[3]|
|Low Overload Drive|
|7|25|38|FR6|CPX02564BA|
|30|46|FR6|CPX03064BA|
|40|61|FR6|CPX04064BA|
|50|72|FR7|CPX05064AA|
|60|87|FR7|CPX06064AA|
|75|105|FR7|CPX07564AA|
|100|140|FR8|CPX10064AA|
|125|170|FR8|CPX12564AA|
|150|205|FR8|CPX15064AA|
|8|200|261|FR9|CPX20064AA|
|250|300|FR9|CPX25064AA|
|9|300|385|FR10|CPX30064AA|
|350|460|FR10|CPX35064AA|
|400|520|FR10|CPX40064AA|
|10|500|590|FR11|CPX50064AA|
|550|650|FR11|CPX55064AA|
|600|730|FR11|CPX60064AA|
|11|650|820|FR11|CPX65064AA|
|700|920|FR12|CPX70064AA|
|800|1030|FR12|CPX80064AA|
|High Overload Drive|
|7|25|38|FR6|CPX02564EA|
|30|46|FR6|CPX03064EA|
|40|61|FR7|CPX04064DA|
|50|72|FR7|CPX05064DA|
|60|87|FR7|CPX06064DA|
|75|105|FR8|CPX07564DA|
|100|140|FR8|CPX10064DA|
|125|170|FR8|CPX12564DA|
|8|150|205|FR9|CPX15064DA|
|200|245|FR9|CPX20064DA|
|9|250|300|FR10|CPX25064DA|
|300|385|FR10|CPX30064DA|
|350|460|FR10|CPX35014DA|
|10|400|520|FR11|CPX40064DA|
|500|590|FR11|CPX50064DA|
|550|650|FR11|CPX55064DA|
|11|600|720|FR12|CPX60064DA|
|650|820|FR12|CPX65064DA|
|700|840|FR12|CPX70064DA|
**----- End of picture text -----**<br>
## _**Notes**_
> 1 See enclosure dimensions beginning on **Page V6-T2-258** .
2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-244**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Enclosed 18-Pulse Drive** =
## **Enclosed 18-Pulse Base Drive Type 3R**[1]
|**Enclosure**<br>**Size**2<br>**Low Overload Drive**|**hp**3<br>**Low Overload Drive**|**Current**<br>**(A)**|**Chassis**<br>**Frame**|**Base Catalog**<br>**Number**4|
|---|---|---|---|---|
|7|25|38|FR6|**CPX02534AA**|
||30|46|FR6|**CPX03034AA**|
||40|61|FR6|**CPX04034AA**|
||50|72|FR7|**CPX05034AA**|
||60|87|FR7|**CPX06034AA**|
||75|105|FR7|**CPX07534AA**|
||100|140|FR8|**CPX10034AA**|
||125|170|FR8|**CPX12534AA**|
||150|205|FR8|**CPX15034AA**|
|8|200|261|FR9|**CPX20034AA**|
||250|300|FR9|**CPX25034AA**|
|**High Overload Drive**|**High Overload Drive**||||
|7|25|38|FR6|**CPX02534DA**|
||30|46|FR6|**CPX03034DA**|
||40|61|FR7|**CPX04034DA**|
||50|72|FR7|**CPX05034DA**|
||60|87|FR7|**CPX06034DA**|
||75|105|FR8|**CPX07534DA**|
||100|140|FR8|**CPX10034DA**|
||125|170|FR8|**CPX12534DA**|
|8|150|205|FR9|**CPX15034DA**|
||200|245|FR9|**CPX20034DA**|
**2**
## _**Notes**_
- 1 All Type 3R drives use the Size F enclosure.
- 2 See enclosure dimensions beginning on **Page V6-T2-258** .
- 3 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
- 4 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-245**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **575V Drives**
**Enclosed 18-Pulse 2 Drive** ~~J~~
## **Enclosed 18-Pulse Base Drive Type 1**
|**Enclosure**||**Current**|**Chassis**|**Base Catalog**|
|---|---|---|---|---|
|**Size**1<br>**Low Overload Drive**|**hp**2<br>**Low Overload Drive**|**(A)**|**Frame**|**Number**3|
|7|25|27|FR6|**CPX02515AA**|
||30|34|FR6|**CPX03015AA**|
||40|41|FR7|**CPX04015AA**|
||50|52|FR7|**CPX05015AA**|
||60|62|FR8<br>~~es~~|**CPX06015AA**<br>~~es~~|
||75<br>100|80<br>100|FR8<br>FR8|**CPX07515AA**<br>**CPX10015AA**|
|8|125|125|FR9|**CPX12515AA**|
||150|144|FR9|**CPX15015AA**|
||200|208|FR9|**CPX20015AA**|
|9|250|261|FR10|**CPX25015AA**|
||300|325|FR10|**CPX30015AA**|
|10|400<br>500|385<br>502|FR10<br>FR11|**CPX40015AA**<br>**CPX50015AA**|
||600|590|FR11|**CPX60015AA**|
|11|650|650|FR12|**CPX65015AA**|
||700|750|FR12|**CPX70015AA**|
||800|820|FR12|**CPX80015AA**|
|**High Overload Drive**|**High Overload Drive**||||
|7|25|27|FR6|**CPX02515DA**|
||30|34|FR7|**CPX03015DA**|
||40|41|FR7|**CPX04015DA**|
||50|52|FR8|**CPX05015DA**|
||60|62|FR8|**CPX06015DA**|
|8|75<br>100|80<br>100|FR8<br>FR9|**CPX07515DA**<br>**CPX10015DA**|
||125|125|FR9|**CPX12515DA**|
||150|144|FR9|**CPX15015DA**|
|9|200|208|FR10|**CPX20015DA**|
||250|261|FR10|**CPX25015DA**|
||300|325|FR10|**CPX30015DA**|
|10|400<br>450|385<br>460|FR11<br>FR11|**CPX40015DA**<br>**CPX45015DA**|
||500|502|FR11|**CPX50015DA**|
|11|600|590|FR12|**CPX60015DA**|
||650|650|FR12|**CPX65015DA**|
||700|750|FR12|**CPX70015DA**|
## _**Notes**_
> 1 See enclosure dimensions beginning on **Page V6-T2-258** .
- 2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
- 3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-246**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Enclosed 18-Pulse Base Drive NEMA 12 Filtered**
|**Enclosed 18-Pulse**|**Enclosed 18-Pulse**|**Enclosed 18-Pulse Base Drive NEMA 12 Filtered**<br>**Enclosed 18-Pulse**|**Enclosed 18-Pulse Base Drive NEMA 12 Filtered**|**Enclosed 18-Pulse Base Drive NEMA 12 Filtered**|**Enclosed 18-Pulse Base Drive NEMA 12 Filtered**||
|---|---|---|---|---|---|---|
|**Drive**||**Enclosure**||**Current**|**Chassis**|**Base Catalog**|
|||**Size**1|**hp**2|**(A)**|**Frame**|**Number**3|
|||**Low Overload Drive**|||||
|||7|25|27|FR6|**CPX02565AA**|
||||30|34|FR6|**CPX03065AA**|
||||40|41|FR7|**CPX04065AA**|
||||50|52|FR7|**CPX05065AA**|
||||60|62|FR8|**CPX06065AA**|
||||75|80|FR8|**CPX07565AA**|
||||100|100|FR8|**CPX10065AA**|
|||8|125|125|FR9|**CPX12565AA**|
||||150|144|FR9|**CPX15065AA**|
||||200|208|FR9|**CPX20065AA**|
|||9|250|261|FR10|**CPX25065AA**|
||||300|325|FR10|**CPX30065AA**|
||||400|385|FR10|**CPX40065AA**|
|||10|500|502|FR11|**CPX50065AA**|
||||600|590|FR11|**CPX60065AA**|
|||11|650|650|FR12|**CPX65065AA**|
||||700|750|FR12|**CPX70065AA**|
||||800|820|FR12|**CPX80065AA**|
|||**High Overload Drive**|||||
|||7|25|27|FR6|**CPX02565DA**|
||||30|34|FR7|**CPX03065DA**|
||||40|41|FR7|**CPX04065DA**|
||||50|52|FR8|**CPX05065DA**|
||||60|62|FR8|**CPX06065DA**|
||||75|80|FR8|**CPX07565DA**|
|||8|100|100|FR9|**CPX10065DA**|
||||125|125|FR9|**CPX12565DA**|
||||150|144|FR9|**CPX15065DA**|
|||9|200|208|FR10|**CPX20065DA**|
||||250|261|FR10|**CPX25065DA**|
||||300|325|FR10|**CPX30065DA**|
|||10|400|385|FR11|**CPX40065DA**|
||||450|460|FR11|**CPX45065DA**|
||||500|502|FR11|**CPX50065DA**|
|||11|600|590|FR12|**CPX60065DA**|
||||650|650|FR12|**CPX65065DA**|
||||700|750|FR12|**CPX70065DA**|
**2**
## _**Notes**_
- 1 See enclosure dimensions beginning on **Page V6-T2-258** .
- 2 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
- 3 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-247**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
**2**
## **Enclosed 18-Pulse Drive**
## **Enclosed 18-Pulse Base Drive Type 3R**[1]
|**Enclosure**||**Current**|**Chassis**|**Base Catalog**|
|---|---|---|---|---|
|**Size**2<br>**Low Overload Drive**|**hp**3<br>**Low Overload Drive**|**(A)**|**Frame**|**Number**4|
|7|25|27|FR6|**CPX02535AA**|
||30|34|FR6|**CPX03035AA**|
||40|41|FR7|**CPX04035AA**|
||50|52|FR7|**CPX05035AA**|
||60|62|FR8|**CPX06035AA**|
||75|80|FR8|**CPX07535AA**|
||100|100|FR8|**CPX10035AA**|
|8|125|125|FR9|**CPX12535AA**|
||150|144|FR9|**CPX15035AA**|
||200|208|FR9|**CPX20035AA**|
|**High Overload Drive**<br>7|**High Overload Drive**<br>25|27|FR6|**CPX02535DA**|
||30|34|FR7|**CPX03035DA**|
||40|41|FR7|**CPX04035DA**|
||50|52|FR8|**CPX05035DA**|
||60|62|FR8|**CPX06035DA**|
||75|80|FR8|**CPX07535DA**|
|8|100<br>125|100<br>125|FR9<br>FR9|**CPX10035DA**<br>**CPX12535DA**|
||150|144|FR9|**CPX15035DA**|
## _**Notes**_
- 1 All Type 3R drives use the Size F enclosure.
- 2 See enclosure dimensions beginning on **Page V6-T2-258** .
- 3 hp ratings are provided as a guideline. Drives should be sized per motor nameplate FLA.
- 4 The 18-pulse clean power assembly includes a standard drive, door-mounted local/remote keypad and enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-248**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Options**
## **Enclosed 18-Pulse Drive Option Board Kits**
The enclosed 18-pulse drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is designed to accept a total of five option boards (see figure below).
**2**
The enclosed 18-pulse drives factory-installed standard board configuration includes an A9 I/O board and an A2 relay output board, which are installed in slots A and B.
## _**9000X Series Option Board Kits**_
## **Option Boards**
## **Option Board Kits**
|A<br>B C D E|**Option Kit Description**1<br>**Allowed Slot**<br>**Locations**2<br>**Field**<br>**Installed**<br>**Factory**<br>**Installed**<br>**SVX Ready Programs**<br>**Catalog**<br>**Number**<br>**Option**<br>**Designator**<br>**Basic**<br>**Local/**<br>**Remote**<br>**Standard**<br>**MSS**<br>**PID**<br>**Multi-P.**<br>**PFC**|
|---|---|
||**Standard I/O Cards**|
||2 RO (NC/NO)<br>B<br>**OPTA2**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/ext +24 Vdc<br>A<br>**OPTA9**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||**Extended I/O Cards**|
||6 DI<br>B, C,**D**, E<br>**OPTB1**<br>**B1**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 RO (NC/NO), 1 RO (NO), 1 therm<br>B, C,**D**, E<br>**OPTB2**<br>**B2**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 AI (mA isolated), 2 AO (mA isolated)<br>B, C,**D**, E<br>**OPTB4**<br>**B4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||3 RO (NO)<br>B, C,**D**, E<br>**OPTB5**<br>**B5**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||3 Pt100 RTD board<br>B, C,**D**, E<br>**OPTB8**<br>**B8**<br>—<br>—<br>—<br>—<br>—<br>■<br>—|
||1 RO (NO), 5 DI 42–240 Vac input<br>B, C,**D**, E<br>**OPTB9**<br>**B9**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||**Communication Cards**3|
||Modbus<br>D,**E**<br>**OPTC2**<br>**C2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Modbus TCP<br>D,**E**<br>**OPTCI**<br>**CI**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||BACnet<br>D,**E**<br>**OPTCJ**<br>**CJ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||EtherNet/IP<br>D,**E**<br>**OPTCQ**<br>**CQ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Johnson Controls N2<br>D,**E**<br>**OPTC2**<br>**CA**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP<br>D,**E**<br>**OPTC3**<br>**C3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||LonWorks<br>D,**E**<br>**OPTC4**<br>**C4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP (D9 connector)<br>D,**E**<br>**OPTC5**<br>**C5**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||CANopen (slave)<br>D,**E**<br>**OPTC6**<br>**C6**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||DeviceNet<br>D,**E**<br>**OPTC7**<br>**C7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Modbus (D9 type connector)<br>D,**E**<br>**OPTC8**<br>**C8**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||RS-232 with D9 connection<br>D,**E**<br>**OPTD3**<br>**D3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
## _**Notes**_
- 1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
- 2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
- 3 OPTC2 is a multi-protocol option card.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-249**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## _**Modbus RTU Network Communications**_
The Modbus Network Card **2** OPTC2 is used for connecting the 9000X Drive as a slave **2** on a Modbus network. The interface is connected by **2** a 9-pin DSUB connector (female) and the baud rate ranges from 300 to 19,200 **2** baud. Other communication parameters include an **2** address range from 1 to 247; a parity of None, Odd or **2** Even; and the stop bit is 1.
## _**PROFIBUS Network Communications**_
The PROFIBUS Network Card OPTC3 is used for connecting the 9000X Drive as a slave on a PROFIBUS-DP network. The interface is connected by a 9-pin DSUB connector (female). The baud rates range from 9.6K baud to 12M baud, and the addresses range from 1 to 127.
## _**LonWorks Network Communications**_
The LonWorks Network Card OPTC4 is used for connecting the 9000X Drive on a LonWorks network. This interface uses Standard Network Variable Types (SNVT) as data types. The channel connection is achieved using a FTT-10A Free Topology transceiver via a single twisted transfer cable. The communication speed with LonWorks is 78 kBits/s.
## _**CANopen (Slave) Communications**_
The CANopen (Slave) Network Card OPTC6 is used for connecting the 9000X Drive to a host system. According to ISO[®] 11898 standard cables to be chosen for CAN bus should have a nominal impedance of 120 ohms, and specific line delay of nominal 5 nS/m. 120 ohm line termination resistors required for installation.
## _**DeviceNet Network Communications**_
The DeviceNet Network Card OPTC7 is used for connecting the 9000X Drive on a DeviceNet Network. It includes a 5.08 mm pluggable connector. Transfer method is via CAN using a two-wire twisted shielded cable with two-wire bus power cable and drain. The baud rates used for communication include 125K baud, 250K baud and 500K baud.
## _**Johnson Controls Metasys N2 Network Communications**_
The OPTC2 fieldbus board provides communication between the 9000X Drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. The N2 fieldbus is available as a factory-installed option and as a field-installable kit.
## _**Modbus/TCP Network Communications**_
The Modbus/TCP Network Card OPTCI is used for connecting the 9000X Drive to Ethernet networks using Modbus protocol. It includes an RJ-45 pluggable connector. This interface provides a selection of standard and custom register values to communicate drive parameters. The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable over Ethernet using a supplied software tool.
## _**BACnet Network Communications**_
The BACnet Network Card OPTCJ is used for connecting the 9000X Drive to BACnet networks. It includes a 5.08 mm pluggable connector. Data transfer is Master-Slave/ Token Passing (MS/TP) RS-485. This interface uses a collection of 30 Binary Value Objects (BVOs) and 35 Analog Value Objects (AVOs) to communicate drive parameters. The card supports 9.6, 19.2 and 38.4 Kbaud communication speeds and supports network addresses 1 to 127.
## _**Ethernet/IP Network Communications**_
The Ethernet/IP Network Card OPTCK is used for connecting the 9000X Drive to Ethernet/Industrial Protocol networks. It includes an RJ45 pluggable connector. The interface uses CIP objects to communicate drive parameters (CIP is “Common Industrial Protocol,” the same protocol used by DeviceNet). The board supports 10 Mbps and 100 Mbps communication speeds. The IP address of the board is configurable by Static, BOOTP and DHCP methods.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-250**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Control/Communication Option Descriptions**
For availability, see Product Selection for base drive voltage required.
**2**
## **Available Control/Communications Options**
|||**Option**|
|---|---|---|
|**Option**|**Description**|**Type**|
|**K1**|**Door-Mounted Speed Potentiometer**—Provides the enclosed 18-pulse drive with the ability to adjust the frequency reference using a door-mounted potentiometer.|Control|
||This option uses the 10 Vdc reference to generate a 0–10V signal at the analog voltage input signal terminal. When the HOA bypass option is added, the speed is||
||controlled when the HOA switch is in the HAND position. Without the HOA bypass option, a two-position switch (labeled local/remote) is provided on the keypad to select<br>speed reference from the speed potentiometer or a remote speed signal.||
|**K2**|**Door-Mounted Speed Potentiometer with HOA Selector Switch**—Provides the enclosed 18-pulse drive with the ability to start/stop and adjust the speed<br>reference from door-mounted control devices or remotely from customer-supplied inputs. In HAND position, the drive will start and the speed is controlled by the door-|Control|
||mounted speed potentiometer. The drive will be disabled in the OFF position. When AUTO is selected, the drive run and speed control commands are via user-supplied dry<br>contact and 4–20 mA signal.||
|**K3**|**3–15 psig Follower**—Provides a pneumatic transducer that converts a 3–15 psig pneumatic signal to either 0–8 Vdc or a 1–9 Vdc signal interface with the enclosed<br>18-pulse drive. The circuit board is mounted on the inside of the front enclosure panel and connects to the user’s pneumatic control system via 6 ft (1.8m) of flexible<br>tubing and a 1/4 inch (6.4 mm) brass tube union.|Control|
|**K4**|**HAND/OFF/AUTO Switch for Non-Bypass Configurations**—Provides a three-position selector switch that allows the user to select either a HAND or AUTO mode<br>of operation. HAND mode is defaulted to keypad operation, and AUTO mode is defaulted to control from an external terminal source. These modes of operation can be|Control|
|**K5**|configured via drive programming to allow for alternate combinations of start and speed sources. Start and speed sources include Keypad, I/O and fieldbus.<br>**MANUAL/AUTO Speed Reference Switch**—Provides door-mounted selector switch for MANUAL/AUTO speed reference.|Control|
|**K6**|**START/STOP Pushbuttons**—Provide door-mounted START and STOP pushbuttons for either bypass or non-bypass configurations.|Control|
|**KF**|**Bypass Test Switch for RB and RA**—Allows the user to energize the AF drive for testing while operating the motor on the bypass controller. The Test Switch is|Addl. bypass|
|**KO**|mounted on the inside of the enclosure door.<br>**Standard Elapsed Time Meter**—Provides a door-mounted elapsed run-time meter.|Control|
|**L1**|**Power On and Fault Power Lights**—Provide a white Power On light that indicates power to the enclosed cabinet and a red fault light that indicates a drive fault<br>has occurred.|Light|
|**L2**|**Bypass Pilot Lights for RB, RA Bypass Options**—A green light indicates when the motor is running in Inverter mode and an amber light indicates when the motor is<br>running in Bypass mode. The lights are mounted on the enclosure door, above the switches.|Addl. bypass|
|**LE**|**Red Run Pilot Light 0.87-Inch (22 mm)**—Provides a red Run pilot light that indicates the drive is running.|Light|
|**P1**|**Input Circuit Breaker**—High interrupting circuit breaker that provides a means of short-circuit protection for the power cables between it and the enclosed 18-pulse|Input|
||drive, and protection from high-level ground faults on the power cable. Allows a convenient means of disconnecting the enclosed 18-pulse drive from the line and the operating<br>mechanism can be padlocked in the OFF position. This is factory mounted in the enclosure. Standard rating is 65 kAIC at 208/480V. 100 kAIC is available as an option.||
|**PE**|**Output Contactor**—Provides a means for positive disconnection of the drive output from the motor terminals. The contactor coil is controlled by the drive’s run or<br>permissive logic. NC and NO auxiliary contacts rated at 10A, 600 Vac are provided for customer use. Bypass options**RB**and**RA**include an output contactor as standard.|Output|
||This option includes a low VA 115 Vac fused control power transformer and is factory mounted in the enclosure.||
|**PF**|**Output Filter**—Used to reduce the transient voltage (DV/DT) at the motor terminals. The output filter is recommended for cable lengths exceeding 100 ft (30.5m) with a|Output|
||drive of 3 hp and above, for cable lengths of 33 ft (10.1m) with a drive of 2 hp and below, or for a drive rated at 525–690V. This option is mounted in the enclosure.||
|**PG**|**MotoRx (300–600 Ft) 1000 V/μS DV/DT Filter**—Used to reduce transient voltage (DV/DT) and peak voltages at the motor terminals. This option is comprised of a 0.5%<br>line reactor, followed by capacitive filtering and an energy recovery/clamping circuit. Unlike the output filter (see option**PF**), the MotoRx recovers most of the energy from the|Output|
||voltage peaks, resulting in a lower voltage drop to the motor, and therefore conserving power. This option is used when the distance between a single motor and the drive<br>is 300–600 ft (91.4–182.9m).||
|**PH**|**Single Overload Relay**—Uses a bimetallic overload relay to provide additional overload current protection to the motor on configurations without bypass options.<br>It is included with the bypass configurations for overload current protection in the bypass mode. The overload relay is mounted within the enclosure, and is manually|Output|
||resettable. Heater pack included.||
|**PI**|**Dual Overload Relays**—This option is recommended when a single drive is operating two motors and overload current protection is needed for each of the motors.|Output|
||The standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example, a 100 hp drive would||
|**PN**|include two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable. Heater packs not included.<br>**Dual Overloads for Bypass**—This option is recommended when a single drive is operating two motors in the Bypass mode and overload current protection is needed|Addl. bypass|
||for each of the motors. The standard configuration includes two bimetallic overload relays, each sized to protect a motor with 50% of the drive hp rating. For example,<br>a 100 hp drive would include two overload relays sized to protect two 50 hp motors. The relays are mounted within the enclosure, and are manually resettable.||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-251**
Adjustable Frequency Drives
2.8
## Low Harmonic Drives
For availability, see Product Selection for base drive voltage required.
**2**
## **Available Control/Communications Options, continued**
|**Available Control/Communications Options, continued**|**Available Control/Communications Options, continued**|**Available Control/Communications Options, continued**|
|---|---|---|
|**Option**<br>**Description**<br>**Option**<br>**Type**|||
|**RA**<br>**Manual HOA Bypass Controller**—The manual HAND/OFF/AUTO (HOA)—three-contactor—bypass option provides a means of bypassing the enclosed 18-pulse drive,<br>allowing the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input HMCP, a fused control power transformer, and a<br>full voltage bypass starter with a door-mounted HOA selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive<br>in the inverter mode. IEC type input, bypass and input contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on<br>**Page V6-T2-257**).<br>Bypass|||
|**RB**<br>**Manual IOB Bypass Controller**—The manual INVERTER/OFF/BYPASS (IOB)—three-contactor—bypass option provides a means of bypassing the enclosed 18-pulse<br>drive, allowing the AC motor to be operated at full speed directly from the AC supply line. This option consists of an input HMCP, a fused control power transformer, and<br>a full voltage bypass starter with a door-mounted IOB selector switch. IEC type input, bypass and input contactors are provided. The contactors are mechanically and<br>electrically interlocked (see wiring diagram on**Page** **V6-T2-257**).<br>Bypass|||
|**RC**<br>**Auto Transfer HOA Bypass Controller**—The manual HAND/OFF/AUTO (HOA)—three-contactor—bypass option provides a means of bypassing the enclosed<br>18-pulse drive, allowing the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the<br>line” operation after a drive trip. This option consists of an input HMCP, a fused control power transformer, and a full voltage bypass starter with a door-mounted HOA<br>selector switch and an INVERTER/BYPASS switch. The HOA switch provides the ability to start and stop the drive in either mode. IEC type input, bypass and input<br>contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on**Page** **V6-T2-257**). Door-mounted pilot lights are provided<br>that indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an amber light indicates when the motor is running in<br>bypass mode.<br>**WARNING**: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.<br>Bypass|||
|**RD**<br>**Auto Transfer IOB Bypass Controller**—The auto INVERTER/OFF/BYPASS (IOB)—three-contactor—bypass option provides a means of bypassing the enclosed<br>18-pulse drive, allowing the AC motor to be operated at full speed directly from the AC supply line. The circuitry provides an automatic transfer of the load to “across the<br>line” operation after a drive trip. This option consists of an input HMCP, a fused control power transformer, and a full voltage bypass starter with a door-mounted IOB<br>selector switch. IEC type input, bypass and input contactors are provided. The contactors are mechanically and electrically interlocked (see wiring diagram on**Page**<br>**V6-T2-257**). Door-mounted pilot lights are provided that indicate bypass or inverter operation. A green light indicates when the motor is running in inverter mode and an<br>amber light indicates when the motor is running in bypass mode.<br>**WARNING**: The motor may restart when the overcurrent relay is reset when operating in bypass, unless the IOB selector switch is turned to the OFF position.<br>Bypass|||
|**RG**<br>**Reduced Voltage Starter for Bypass**—Used in conjunction with bypass option RA, RB, RC or RD. This option adds reduced voltage soft starter to bypass assembly for<br>soft starting in bypass mode.<br>Bypass|||
|**S7**<br>**10.00-Inch (254.0 mm) Expansion**—Expansion cabinet allows for special components, customer-supplied components or oversized cables.<br>**NOTE:**Enclosure expansion rated Type 1 only.<br>Enclosure|||
|**S8**<br>**20.00-Inch (508.0 mm) Expansion**—Expansion cabinet allows for special components, customer-supplied components or oversized cables.<br>**NOTE:**Enclosure expansion rated Type 1 only.<br>Enclosure|||
|**S9**<br>**Space Heater**—Prevents condensation from forming in the enclosure when the drive is inactive or in storage. Includes a thermostat for variable temperature control.<br>The heater requires a customer-supplied 115V remote supply source.<br>Enclosure|||
|**Dissipated Watt Losses**<br>**Horsepower**<br>**40**<br>**50**<br>**60**|**75**<br>**100**<br>**125**<br>**150**<br>**200**<br>**250**<br>**300**<br>**350**<br>**400**<br>**450**<br>**500**<br>**600**<br>**700**<br>**800**||
|**Watts**<br>1844<br>2170<br>2540|3040<br>4011<br>4940<br>5730<br>8020<br>9383<br>11600<br>13600<br>15700<br>16250<br>17976<br>20393<br>27200<br>31400||
|**Conformal (Varnished) Coating**<br>**_Notes_**<br>1 See catalog number description to order.<br>2 <br>**Chassis**<br>**Frame**<br>**Delivery**<br>**Code**<br>FR6<br>FP<br>FR7<br>FP<br>FR8<br>FP<br>—<br>—|1<br> <br>**Chassis**<br>**Frame**<br>**Delivery**<br>**Code**<br>FR9<br>FP<br>FR10<br>FP<br>FR11<br>FP<br>FR12<br>FP|**480V Input Disconnect Selection**2<br>**Horsepower**<br>**P1 Input**<br>**Breaker**<br>**Bypass Motor Circuit Protector**<br>**(RA, RB, RC, RD)**|
|||25<br>HFD3050<br>HMCP050K2C|
|||30<br>HFD3060<br>HMCP100R3C|
|||40<br>HFD3080<br>HMCP100R3C|
|||50<br>HFD3100<br>HMCP100R3C|
|||60<br>HFD3100<br>HMCP150T4C|
|||75<br>HFD3125<br>HMCP150T4C|
|||100<br>HFD3150<br>HMCP150U4C|
|||125<br>HFD3200<br>HMCP250W5C|
|||150<br>HFD3225<br>HMCP250W5C|
|||200<br>HKD3300<br>HMCP400X5C|
|||250<br>HKD3400<br>HMCP400X5C|
|||300–400<br>HLD3600<br>HMCP600L6W|
|||500–600<br>HND3800<br>HMCP800X7W|
|||650–800<br>HND312<br>3|
> 1 See catalog number description to order.
> 2 Contact factory for 208V and 575V applications.
> 3 Contact factory.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-252**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Enclosed Drive Options**
## **Meter Options**
## **Light Options**
|**Light Options**||
|---|---|
||**Catalog**|
|**Description**|**Number Suffix**|
|Power on, run, fault LED lights (22 mm)|**L1**|
|Power on, fault LED lights (22 mm)|**L3**|
|Green LED run light (22 mm)|**LA**|
|Green LED stop light (22 mm)|**LD**|
|Red LED run light (22 mm)|**LE**|
|Red LED stop light (22 mm)|**LF**|
|Red LED fault light (22 mm)|**LG**|
|Power on white LED light (22 mm)|**LJ**|
|Miscellaneous LED light (22 mm)|**LU**|
|**Meter Options**||
|---|---|
||**Catalog**|
|**Description**<br>Standard elapsed time meter|**Number Suffix**<br>**KO**|
|Frequency meter|**KS**|
|MP-3000 relay with URTD|**KV**|
|MP-3000 relay with URTD and CTs|**KU**|
## **Enclosure Options**
|Red LED fault light (22 mm)|**LG**|**Enclosure Options**||
|---|---|---|---|
|Power on white LED light (22 mm)|**LJ**|**Enclosure**<br>**Size**|**Catalog**<br>**Number Suffix**|
|Miscellaneous LED light (22 mm)|**LU**|**10.00 Inch (254.0 mm) Expansion**||
|**Control Options**||7<br>8|**S7**<br>**S7**|
||**Catalog**|9|**S7**|
|**Description**|**Number Suffix**|10|**S7**|
|Door-mounted speed potentiometer|**K1**|11|**S7**|
|Door-mounted speed potentiometer with HOA selector switch<br>3–15 psig follower|**K2**<br>**K3**|**20.00 Inch (508.0 mm) Expansion**<br>7|**S8**|
|HOA selector switch|**K4**|8|**S8**|
|MANUAL/AUTO reference switch|**K5**|9|**S8**|
|START-STOP pushbuttons|**K6**|10|**S8**|
|Type D2 control relay|**SD**|11|**S8**|
|On-delay relay|**SE**|**Space Heater**1||
|Off-delay relay<br>Additional terminal blocks per 4 points|**SF**<br>**SD**|7<br>8|**S9**<br>**S9**|
|||9|**S9**|
|||10|**S9**|
|**Bypass Control Options**<br>**Description**<br>Bypass test switch used with RA and RB<br>Inverter/bypass pilot lights|**Catalog**<br>**Number Suffix**<br>**KF**<br>**L2**|11<br>**Plastic Nameplate**<br>7<br>8<br>9|**S9**<br>**SN**<br>**SN**<br>**SN**|
|||10|**SN**|
|||11|**SN**|
**2**
## _**Note**_
> 1 Requires customer-supplied 115 Vac supply.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-253**
Adjustable Frequency Drives
2.8
## Low Harmonic Drives
**2**
## **208V and 230V Power Options, 25–200 hp**
||**Catalog**|
|---|---|
|**Description**<br>Input breaker|**Number Suffix**<br>**P1**|
|Output contactor|**PE**|
|Single overload relay|**PH**|
|Dual overload relays|**PI**|
|MOV|**P7**|
|50 kA surge protective device|**P8**|
|100 kA surge protective device|**P9**|
## **208V and 230V Bypass Options, 25–200 hp**
||**Catalog**|
|---|---|
|**Description**|**Number Suffix**|
|Manual HOA bypass controller|**RA**|
|IOB bypass controller|**RB**|
|Auto transfer HOA bypass controller|**RC**|
|Auto transfer IOB bypass controller|**RD**|
|Reduced voltage starter for bypass|**RG**|
|Dual overloads for bypass|**PN**|
## **480 and 575V Bypass Options, 25–800 hp**
## **480 and 575V Power Options, 25–800 hp**
||**Catalog**|
|---|---|
|**Description**|**Number Suffix**|
|Input breaker|**P1**|
|Output contactor|**PE**|
|Output filter|**PF**|
|MotoRx (300–600 Ft) DV/DT filter|**PG**|
|Single overload relay<br>Dual overload relays|**PH**<br>**PI**|
|Input MOV|**P7**|
|50 kA surge protective device|**P8**|
|100 kA surge protective device|**P8**|
||**Catalog**|
|---|---|
|**Description**|**Number Suffix**|
|Manual HOA bypass controller|**RA**|
|IOB bypass controller|**RB**|
|Auto transfer HOA bypass controller|**RC**|
|Auto transfer IOB bypass controller|**RD**|
|Reduced voltage starter for bypass|**RG**|
|Dual overloads for bypass|**PN**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-254**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Technical Data and Specifications**
|**Enclosed 18-Pulse Drives**||
|---|---|
|**Description**|**Specification**|
|**Primary Design Features**||
|45–66 Hz input frequency|Standard|
|Output: AC volts maximum|Input voltage base|
|Output frequency range|0–320 Hz|
|Initial output current (IH)|250% for 2 seconds|
|Overload (1 minute [IH/IL])|150%/110%|
|Enclosure space heater|Optional|
|Oversize enclosure|Standard|
|Output contactor|Optional|
|Bypass motor starter|Optional|
|Listings|UL, cUL, 508C|
|**Protection Features**||
|Incoming line fuses|Standard 200 kAIC rating|
|AC input circuit disconnect|Optional|
|Phase rotation insensitive|Standard|
|EMI filter|Standard FR6 thru FR91|
|Input phase loss protection|Standard|
|Input overvoltage protection|Standard|
|Line surge protection|Standard|
|Output short-circuit protection|Standard|
|Output ground fault protection|Standard|
|Output phase protection|Standard|
|Overtemperature protection|Standard|
|DC overvoltage protection|Standard|
|Drive overload protection|Standard|
|Motor overload protection|Standard|
|Programmer software|Optional|
|Local/remote keypad|Standard|
|Keypad lockout|Standard|
|Fault alarm output|Standard|
|Built-in diagnostics|Standard|
|Surge protective device|Optional|
|**Description**|**Specification**|
|---|---|
|**Input/Output Interface Features**||
|Setup adjustment provisions||
|Remote keypad/display|Standard|
|Personal computer<br>Operator control provisions|Standard|
|Drive mounted keypad/display|Standard|
|Remote keypad/display|Standard|
|Conventional control elements|Standard|
|Serial communications<br>115 Vac control circuit|Optional<br>Optional|
|Speed setting inputs<br>Keypad|Standard|
|0–10 Vdc potentiometer/voltage signal|Standard|
|4–20 mA isolated|Configurable|
|4–20 mA differential|Configurable|
|3–15 psig<br>Analog outputs|Optional|
|Speed/frequency|Standard|
|Torque/load/current|Programmable|
|Motor voltage|Programmable|
|Kilowatts|Programmable|
|0–10 Vdc signals|Configurable w/jumpers|
|4–20 mA DC signals<br>Isolated signals|Standard<br>Standard|
|Discrete outputs||
|Fault alarm|Standard|
|Drive running|Standard|
|Drive at set speed<br>Optional parameters|Programmable<br>14|
|Dry contacts<br>Additional discrete outputs|2 Form C contacts available<br>Optional|
|**Communications**||
|RS-232|Standard|
|RS-422/485|Optional|
|DeviceNet™<br>Modbus RTU|Optional<br>Optional|
|CANopen (slave)|Optional|
|PROFIBUS-DP|Optional|
|LonWorks|Optional|
|Johnson Controls Metasys N2|Optional|
|EtherNet/IP/Modbus TCP|Optional|
|BACnet|Optional|
**2**
## _**Note**_
> 1 The EMI filter is optional in FR10 and larger.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-255**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
**2**
## **Enclosed 18-Pulse Drives**
|**Enclosed 18-Pulse Drives**||
|---|---|
|**Description**|**Specification**|
|**Performance Features**||
|Sensorless vector control|Standard|
|Volts/hertz control|Standard|
|IR and slip compensation<br>Electronic reversing|Standard<br>Standard|
|Dynamic braking|Optional|
|DC braking|Standard|
|PID set point controller|Programmable|
|Critical speed lockout|Standard|
|Current (torque) limit|Standard|
|Adjustable acceleration/deceleration<br>Linear or S curve accel/decel|Standard<br>Standard|
|Jog at preset speed|Standard|
|Thread/preset speeds|7|
|Automatic restart|Selectable|
|Coasting motor start<br>Coast or ramp stop selection|Standard<br>Standard|
|Elapsed time meter<br>Carrier frequency adjustment|Optional<br>1–16 kHz|
|**Standard Conditions for Application and Service**||
|Maximum operating ambient temperature|0–50°C up to FR9|
||0–40°C FR10 and larger, consult factory for 50°C<br>rating above FR9|
|Storage temperature|–40 to 60°C|
|Humidity (maximum), noncondensing|95%|
|Altitude (maximum without derate)|3300 ft (1000m)|
|Line voltage variation|+10/–15%|
|Line frequency variation|45–66 Hz|
|Efficiency<br>Power factor (displacement)|>95%<br>0.99+|
|Power factor (apparent)|0.99|
## **Standard I/O Specifications**
|**Description**|**Specification**|
|---|---|
|Six–digital input programmable|24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V,Ri>5 kohms|
|Two–analog input configurable|Voltage: 0–±10V, Ri>200 kohms|
|w/jumpers|Current: 0 (4)–20 mA, Ri= 250 ohms|
|Two–digital output programmable|Form C relays 250 Vac|
||30 Vdc 2 amp resistive|
|One–analog output programmable|0–20 mA, RLmax. 500 ohms 10 bits ±2%|
|configurable w/jumper||
## **I/O Specifications for Control/Communication Options**
|**Description**|**Specification**|
|---|---|
|Analog voltage, input|0–±10V, Ri ><br>~~2~~00 kilohms|
|Analog current, input|0 (4)–20 mA, Ri= 250 ohms|
|Digital input|24V: “0” <<br>~~1~~0V, “1” ><br>~~1~~8V, Ri>5 kilohms|
|Auxiliary voltage|24V (±20%), max. 50 mA|
|Reference voltage|10V ±3%, max. 10 mA|
|Analog current, output|0 (4)–20 mA, RL= 500 kilohms, resolution|
||10 bit, accuracy <<br>~~±~~2%|
|Analog voltage, output|0 (2)–10V, RL ><br>~~1~~kilohm, resolution|
||10 bit, accuracy <<br>~~±~~2%|
|Relay output max. switching voltage|300 Vdc, 250 Vac|
|Relay output max. switching load|3A/24 Vdc, 300 Vdc, 250 Vac1|
|Relay output max. continuous load|2A rms|
|Thermistor input|Rtrip= 4.7 kohms|
## _**Note**_
> 1 For applications above 3A consult instruction manual.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-256**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Wiring Diagrams**
## **Power Diagram Up to FR9**
**==> picture [87 x 226] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit<br>Breaker<br>Input<br>Fusing<br>Inverter Input<br>I Contactor<br>18-Pulse<br>Transformer<br>18-Pulse<br>Diode Bridge<br>9000X<br>Drive<br>Motor<br>**----- End of picture text -----**<br>
**Power Diagram FR10 and Larger**
**==> picture [100 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
Circuit<br>Breaker<br>Input<br>Fusing<br>18-Pulse<br>Transformer<br>Pre-charge<br>Complete<br>Contactor<br>6-Pulse<br>Diode Bridge<br>9000X<br>12-Pulse Drive<br>Motor<br>**----- End of picture text -----**<br>
## **Power Diagram Up to FR9 with Bypass**
**==> picture [179 x 273] intentionally omitted <==**
**----- Start of picture text -----**<br>
HMCP<br>Inverter InputContactor I<br>Input<br>Fusing<br>18-Pulse<br>Transformer<br>( IT. )<br>Optional<br>18-Pulse Reduced<br>Diode Bridge Voltage Starter<br>9000X<br>Drive<br>Mechanical<br>Interlock<br>Output M L Bypass<br>Contactor Contactor<br>Overload<br>Motor<br>**----- End of picture text -----**<br>
**Power Diagram FR10 and Larger with Bypass**
**==> picture [203 x 281] intentionally omitted <==**
**----- Start of picture text -----**<br>
HMCP<br>Inverter InputContactor I<br>Input<br>Fusing<br>( IT. )<br>Optional<br>18-Pulse Reduced<br>Transformer Voltage Starter<br>Pre-charge<br>Complete<br>Contactor<br>6-Pulse<br>Diode Bridge<br>9000X<br>12-Pulse Drive<br>Mechanical<br>Interlock<br>Output M L Bypass<br>Contactor Contactor<br>Overload<br>Motor<br>**----- End of picture text -----**<br>
**2**
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-257**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
## **Dimensions**
Approximate Dimensions in Inches (mm)
**2 Enclosure Size 7**
## **25–150 hp IL and 25–125 hp IH 480V—25–100 hp IL and 25–75 hp IH 575V**
**==> picture [435 x 563] intentionally omitted <==**
**----- Start of picture text -----**<br>
Exhaust Air 4.79<br>(121.7)<br>20.00 For 15.00<br>(508.0) Cable (381.0)<br>Entry<br>26.25<br>(666.8) Hinged 2.00<br>Side Door 10.00 (50.8)<br>Clearance at 90º (254.0)<br>Top View<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>Keypad<br>Flanged Disconnect Supplied<br>With Circuit Breaker<br>When Specified<br>Operator Elements<br>When Specified, Mounted<br>On These Panels<br>84.37<br>(2143.0) 93.92 Door Handle<br>90.00 (2385.6) (key-lock optional)<br>(2286.0)<br>Quarter Turn Latch<br>(three places)<br>15.50 30.00<br>(393.7) ø0.56 (ø14.2) Dia. (762.0)<br>Mounting Holes<br>21.50 (five places) Opening For Bottom<br>(546.1) Cable Entry<br>14.90<br>Side View (378.5) 10.50<br>18.75 4.25 (266.7)<br>(476.3) (107.9)<br>5.75 7.00<br>(146.1) (177.8)<br>1.75<br>Finish: Enclosure—ANSI 61 Gray (light) (44.5) 24.45<br>Material: Enclosure and Backplate— 12 ga. = 0.1046 Cold Rolled Steel (621.0) 28.05<br>(712.5)<br>Bottom View<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-258**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size 8**
## **200–250 hp IL and 150–200 hp IH 480V—125–200 hp IL and 100–150 hp IH 575V**
**2**
**==> picture [500 x 575] intentionally omitted <==**
**----- Start of picture text -----**<br>
1.25 31.00<br>(31.8) (787.4)<br>8.25<br>(209.6)<br>For Top<br>Cable Entry<br>(two places)<br>Top View<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>Drive<br>Circuit Breaker<br>93.50<br>90.00 84.37<br>(2374.9)<br>(2286.0) (2143.0)<br>Door Handle<br>(key-lock optional)<br>21.45 21.31<br>24.00<br>(544.8) (541.3)<br>(609.6) 48.00<br>(1219.2)<br>Side View<br>For Bottom<br>Cable Entry<br>9.50<br>(241.3) 12.50<br>22.47 32.20 (317.5)<br>(570.7) 13.97 (817.9)<br>(354.8) 7.73<br>5.48 ø0.56<br>(196.3)<br>(139.2) (ø14.2)<br>Finish: Enclosure—ANSI 61 Gray (light)<br>(five places)<br>Material: Enclosure and Backplate— 3.01 (76.5)<br>12 ga. = 0.1046 Cold Rolled Steel 37.47 (951.7)<br>45.22 (1148.6)<br>Bottom View<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-259**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size 9**
**2**
**300–400 hp IL and 250–350 hp IH 480V—250–400 hp IL and 200–300 hp IH 575V**
**==> picture [479 x 582] intentionally omitted <==**
**----- Start of picture text -----**<br>
43.50 (1104.9)<br>1.50 (38.1)<br>8.75<br>(222.3)<br>7.46 x 15.00<br>(189.5 x 381.0)<br>Access in Top<br>(two places)<br>90 Max. 90 Max.<br>Door Door<br>(694.9)27.36 Opening Opening 27.06<br>(687.3)<br>29.05<br>(737.9)<br>Top View<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>93.50<br>(2374.9) Drive<br>Circuit Breaker<br>90.00<br>(2286.0)<br>Door Handle<br>(key-lock optional)<br>Access<br>Plate<br>(4 places)<br>24.00 (609.6) 60.00 (1524.0)<br>25.14 (638.6) Front View 8.50 x 12.00 (215.9 x 304.8)<br>Side View 32.72 (831.1) Bottom Access<br>ø0.56 (ø14.2) Dia.<br>Mounting Hole<br>(five places)<br>25.00<br>(635.0)<br>18.84<br>(478.5)<br>Finish: Enclosure—ANSI 61 Gray (light) 8.20 11.93<br>(303.0)<br>Material: Enclosure and Backplate— (208.3)<br>12 ga. = 0.1046 Cold Rolled Steel<br>2.00 (50.8) 22.90 (581.7)<br>46.30 (1176.0)<br>54.90 (1394.5)<br>Bottom View<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-260**
Adjustable Frequency Drives
2.8
Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size 10**
## **500–600 hp IL and 400–500 hp IH 480V—500–600 hp IL and 400–500 hp IH 575V**
**2**
**==> picture [494 x 589] intentionally omitted <==**
**----- Start of picture text -----**<br>
15.63<br>(397.0)<br>9.03<br>(229.4)<br>21.00 x 10.00<br>(533.4 x 254.0)<br>Access in Top<br>Top View<br>4.00 (101.6) Minimum<br>Free Air Space Required<br>Flanged<br>Disconnect<br>Supplied with<br>Circuit Breaker<br>When Specified<br>Keypad<br>Door Handle<br>Operator (key-lock optional)<br>Elements<br>When<br>Specified,<br>Mounted<br>on These<br>93.50 Panels<br>(2374.9)<br>90.00<br>(2286.0)<br>84.37<br>(2143.0)<br>Quarter-Turn<br>Latch (four places)<br>Intake Ventilating<br>Slots (filtered on<br>Type 12)<br>35.75 (908.1) 35.75 (908.1)<br>30.50 (774.7) 80.00 (2032.0)<br>31.75 (806.5) Front View<br>15.64 21.00 x 10.00 (533.4 x 254.0)<br>Side View (397.3) Bottom Access<br>29.04<br>(737.6) 17.79<br>4.87 (451.9)<br>(123.7)<br>2.00 (50.8)<br>38.00 (965.2)<br>42.02 (1067.3)<br>Finish: Enclosure – ANSI 61 Gray (light)<br>Material: Enclosure and Backplate— 78.02 (1981.7)<br>12 ga. = 0.1046 Cold Rolled Steel Bottom View<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-261**
2.8
## Adjustable Frequency Drives
## Low Harmonic Drives
Approximate Dimensions in Inches (mm)
## **Enclosure Size F Type 3R Drives**
**2**
## **25–250 hp IL and 25–200 hp IH 480V—25–200 hp IL and 25–150 hp IH 575V Type 3R Drives**
**==> picture [420 x 308] intentionally omitted <==**
**----- Start of picture text -----**<br>
60.00 (1524.0) 37.50 (952.5)<br>18.00 x 8.50<br>(457.2 x 215.9)<br>Exhaust Air Side Access<br>Venting Slots<br>Enclosure Flanged<br>Door Stop Disconnect<br>Supplied with<br>Keypad Located Circuit Breaker<br>Inside Locking When Specified<br>Enclosure Door Key Locking<br>Three-Position<br>Operator Elements Latch<br>When Specified, 93.50<br>Mounted Inside Filtered (2374.9)<br>Locking Enclosure Door Intake Air<br>Ventilating<br>Slots<br>35.75 (908.0) 25.84<br>(656.2) Exhaust Air<br>48.00 (1219.2)<br>29.58 Venting Slots<br>(751.2)<br>18.00 x 8.50<br>(457.2 x 215.9)<br>Bottom Access<br>29.32<br>(744.7)<br>9.08<br>(230.5)<br>3.11 (78.9)<br>6.82 37.43 (950.7)<br>(173.3) 45.32 (1151.1)<br>**----- End of picture text -----**<br>
## **Enclosed 18-Pulse Drive Enclosure Dimensions**
|**Enclosure**||||**Approx. Shipping**|
|---|---|---|---|---|
|**Size**1|**Width**|**Height**|**Depth**|**Weight in Lbs (kg)**|
|7|30.00 (762.0)|90.00 (2286.0)|21.50 (546.1)|1000 (454)|
|8<br>9|48.00 (1219.2)<br>60.00 (1524.0)|90.00 (2286.0)<br>90.00 (2286.0)|26.14 (664.0)<br>25.74 (653.8)|1400 (636)<br>1800 (817)|
|10|80.00 (2032.0)|90.00 (2286.0)|31.75 (806.5)|2100 (953)|
|1123|120.00 (3048.0)|90.00 (2286.0)|25.74 (653.8)|2500 (1,135)|
|F4|60.00 (1524.0)|93.50 (2374.9)|37.50 (952.5)|2500 (1,135)|
## _**Notes**_
> 1 Enclosure sizes accommodate drive and options, including bypass and disconnect. For other power options, consult your Eaton representative.
- 2 Consult factory. Limited power options available.
> 3 Enclosure size 11 consists of two of the enclosure size 9.
- 4 All Type 3R drives use the Size F enclosure.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-262**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
## **LCX9000 Liquid Cooled Adjustable Frequency Drives**
## **Contents**
|**Contents**||**2**|
|---|---|---|
|**_Description_**|**_Page_**||
|LCX9000 Drives||**2**|
|Catalog Number Selection . . . . . . . . . . . . . . . .<br>Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-264**<br>**V6-T2-265**|**2**|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<br>Technical Data and Specifications . . . . . . . . . .|**V6-T2-268**<br>**V6-T2-270**|**2**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . .<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-271**<br>**V6-T2-273**|**2**|
## **Product Description**
The LCX9000 Liquid Cooled Drive family continues Eaton’s tradition of providing state-of-the-industry products, by taking advantage of liquid cooling technology in lieu of air-cooling techniques.
The LCX9000 drives are liquid-cooled products that utilize potable water or a water-glycol mixture as a cooling medium.
## **Features and Benefits**
- Compact size and low ● CE mark ensures heat transfer rates allow compliance with the enclosure size to be greatly Electromagnetic reduced, which is especially Compatibility Directive beneficial in UL Type 4X (EMC) and the Low Voltage applications Directive (LVD)
- Reliable drive with over 500,000 hours MTBF based on MIL 217
- Design is modular, with control and power modules 500,000 hours MTBF independent of each other. based on MIL 217 Connection between ● Currently supports power and control modules DeviceNet, PROFIBUS-DP, can be direct or extended Modbus RTU and Modbus via a fiber optic cable TCP communication
- ● Same reliable control protocols
- Same reliable control protocols module and operating ● Separately mounted line system as the SPX9000 reactor included with AC air-cooled drives fed models
## **Standards and Certifications**
> ● CE
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-263**
Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives
## 2.9
## **Catalog Number Selection**
**LCX9000 Liquid Cooled Adjustable Frequency Drives**
**2**
**– LCX 016 A 0 4 A 3 B 2**
**==> picture [236 x 311] intentionally omitted <==**
**----- Start of picture text -----**<br>
Product Family<br>LCX = High performance, liquid-cooled drive<br>Current Rating<br>480V<br>016 = 16A 385 = 385A<br>022 = 22A 460 = 460A<br>031 = 31A 520 = 520A Softw are Series<br>038 = 38A 590 = 590A A = Standard<br>045 = 45A 650 = 650A<br>061 = 61A 730 = 730A<br>072 = 72A 820 = 820A<br>087 = 87A 920 = 920A Enclosure R ating<br>105 = 105A H10 = 1030A 0 = Open chassis<br>140 = 140A H11 = 1150A<br>168 = 168A H13 = 1370A<br>205 = 205A H16 = 1640A<br>261 = 261A H20 = 2060A<br>300 = 300A H23 = 2300A Voltage Rating<br>690V 4 = 380–500V<br>5 = 520–690V<br>170 = 170A 590 = 590A<br>208 = 208A 650 = 650A<br>261 = 261A 750 = 750A<br>325 = 325A 820 = 820A<br>385 = 385A H10 = 1030A Keypad<br>416 = 416A H11 = 1180A A = Alphanumeric<br>460 = 460A H13 = 1300A<br>502 = 502A H15 = 1500A<br>Input Options<br>3 = Three-phase, EMC T<br>7 = DC Input<br>**----- End of picture text -----**<br>
**_ _ _ _ _ _ Options** List options in alphabetical order. **Extended I/O Card Options A3** = 2 RO, therm **A4** = Encoder low volt +5V/15V/24V **A5** = Encoder high volt +15V/24V **A7** = Dual encoder +15V/24V **A8** = 6 DI, 1 DO, 2 AI, 1AO **AE** = Encoder with 2 DOs **B1** = 6 DI, 1 ext +24 Vdc/EXT +24 Vdc **B2** = 1 RO (NC-NO), 1 RO (NO), 1 therm **B4** = 1 AI (mA isolated), 2 AO (mA isolated), 1 ext +24 Vdc/EXT + 24 Vdc **B5** = 3 RO (NO) **B8** = 1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100 **B9** = 1 RO (NO), 5 DI 42–240 Vac input **BB** = SPI, absolute encoder **Communication Cards CA** = Johnson Controls N2 **CI** = Modbus TCP **C2** = Modbus **C3** = PROFIBUS DP **C4** = LonWorks **C5** = PROFIBUS DP (D9 Connector) **C6** = CANopen (Slave) **C7** = DeviceNet **C8** = Modbus (D9 Type Connector) **D1** = Adapter **D2** = Adapter **D3** = RS-232 with D9 Connection **Board Modifications 2** = Varnished boards **Brake Chopper Options**[1] **N** = No brake chopper circuit **B** = Internal brake chopper
_**Note**_
> 1 Brake chopper is only available in 480V CH3 drives.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-264**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
## **Product Selection**
## **LCX9000 Liquid Cooled 380–500 Vac Liquid Cooled Drives Drives**
**Motor Output**
**2**
|**Motor Output**||||||
|---|---|---|---|---|---|
|**Current**||||||
|**Thermal, Ith (A)**|**IL (A)**|**IH (A)**|**kW**|**Chassis**|**Catalog Number**|
|16|15|11|7.5|CH3|**LCX016A0-4A3N2**|
|22|20|15|11|CH3|**LCX022A0-4A3N2**|
|31|28|21|15|CH3|**LCX031A0-4A3N2**|
|38|35|25|18.5|CH3|**LCX038A0-4A3N2**|
|45|41|30|22|CH3|**LCX045A0-4A3N2**|
|61|55|41|30|CH3|**LCX061A0-4A3N2**|
|72|65|48|37|CH4|**LCX072A0-4A3N2**|
|87|79|58|45|CH4|**LCX087A0-4A3N2**|
|105|95|70|55|CH4|**LCX105A0-4A3N2**|
|140|127|93|75|CH4|**LCX140A0-4A3N2**|
|168|153|112|90|CH5|**LCX168A0-4A3N2**|
|205|186|137|110|CH5|**LCX205A0-4A3N2**|
|261|237|174|132|CH5|**LCX261A0-4A3N2**|
|300|273|200|160|CH61|**LCX300A0-4A3N2**|
|385|350|257|200|CH61|**LCX385A0-4A3N2**|
|460|418|307|250|CH72|**LCX460A0-4A3N2**|
|520|473|347|250|CH72|**LCX520A0-4A3N2**|
|590|536|393|315|CH72|**LCX590A0-4A3N2**|
|650|591|433|355|CH72|**LCX650A0-4A3N2**|
|730|664|487|400|CH72|**LCX730A0-4A3N2**|
|820|745|547|450|CH63|**LCX820A0-4A3N2**|
|920|836|613|500|CH63|**LCX920A0-4A3N2**|
|1030|936|687|560|CH63|**LCXH10A0-4A3N2**|
|1150|1045|766|600|CH63|**LCXH11A0-4A3N2**|
|1370|1245|913|700|CH74|**LCXH13A0-4A3N2**|
|1640|1491|1093|900|CH74|**LCXH16A0-4A3N2**|
|2060|1873|1373|1100|CH74|**LCXH20A0-4A3N2**|
|2300|2091|1533|1200|CH74|**LCXH23A0-4A3N2**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-265**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
**2**
## **LCX9000 Liquid Cooled Drives**
## **525–690 Vac Liquid Cooled Drives**
**Motor Output**
|**Motor Output**||||||
|---|---|---|---|---|---|
|**Current**<br>**Thermal, Ith (A)**|**IL (A)**|**IH (A)**|**kW**|**Chassis**|**Catalog Number**|
|170|155|113|110|CH61|**LCX170A0-5A3N2**|
|208|189|139|132|CH61|**LCX208A0-5A3N2**|
|261|237|174|160|CH72|**LCX261A0-5A3N2**|
|325<br>385|295<br>350|217<br>257|200<br>250|CH72<br>CH72|**LCX325A0-5A3N2**<br>**LCX385A0-5A3N2**|
|416|378|277|250|CH72|**LCX416A0-5A3N2**|
|460|418|307|300|CH72|**LCX460A0-5A3N2**|
|502|456|335|355|CH72|**LCX502A0-5A3N2**|
|590|536|393|400|CH63|**LCX590A0-5A3N2**|
|650|591|433|450|CH63|**LCX650A0-5A3N2**|
|750<br>820|682<br>745|500<br>547|500<br>560|CH63<br>CH74|**LCX750A0-5A3N2**<br>**LCX820A0-5A3N2**|
|920|836|613|650|CH74|**LCX920A0-5A3N2**|
|1030|936|687|700|CH74|**LCXH10A0-5A3N2**|
|1180|1073|787|800|CH74|**LCXH11A0-5A3N2**|
|1300|1182|867|900|CH74|**LCXH13A0-5A3N2**|
|1500|1364|1000|1000|CH74|**LCXH15A0-5A3N2**|
## **540–675 Vdc Liquid Cooled Inverter Units**
## **Drive Output**
|**Current**<br>**Thermal**|**Rated Cont.**|**Rated Cont.**|**Motor Output Power**<br>**Optimum Motor**|**Optimum Motor**|**Power Loss**<br>**c/a/T**|||
|---|---|---|---|---|---|---|---|
|**Ith(A)**<br>16|**IL (A)**<br>15|**IH (A)**<br>11|**at Ith400V (kW)**<br>7.5|**at Ith500V (kW)**<br>11|**(kW)**<br>0.4/0.2/**0.6**|**Chassis**<br>CH3|**Catalog Number**<br>**LCX016A0-4A7B2**|
|22|20|15|11|15|0.5/0.2/**0.7**|CH3|**LCX022A0-4A7B2**|
|31|28|21|15|18.5|0.7/0.2/**0.9**|CH3|**LCX031A0-4A7B2**|
|38|35|25|18.5|22|0.8/0.2/**1.0**|CH3|**LCX038A0-4A7B2**|
|45|41|30|22|30|1.0/0.3/**1.3**|CH3|**LCX045A0-4A7B2**|
|61|55|41|30|37|1.3/0.3/**1.5**|CH3|**LCX061A0-4A7B2**|
|72<br>87|65<br>79|48<br>58|37<br>45|45<br>55|1.2/0.3/**1.5**<br>1.5/0.3/**1.8**|CH4<br>CH4|**LCX072A0-4A7N2**<br>**LCX087A0-4A7N2**|
|105|95|70|55|75|1.8/0.3/**2.1**|CH4|**LCX105A0-4A7N2**|
|140|127|93|75|90|2.3/0.3/**2.6**|CH4|**LCX140A0-4A7N2**|
|168|153|112|90|110|2.5/0.3/**2.8**|CH5|**LCX168A0-4A7N2**|
|205|186|137|110|132|3.0/0.4/**3.4**|CH5|**LCX205A0-4A7N2**|
|261|237|174|132|160|4.0/0.4/**4.4**|CH5|**LCX261A0-4A7N2**|
|300<br>385|273<br>350|200<br>257|160<br>200|200<br>250|4.5/0.4/**4.9**<br>5.5/0.5/**6.0**|CH61<br>CH61|**LCX300A0-4A7N2**<br>**LCX385A0-4A7N2**|
|460|418|307|250|315|5.5/0.5/**6.0**|CH62|**LCX460A0-4A7N2**|
|520|473|347|250|355|6.5/0.5/**7.0**|CH62|**LCX520A0-4A7N2**|
|590|536|393|315|400|7.5/0.6/**8.1**|CH62|**LCX590A0-4A7N2**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-266**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
**LCX9000 Liquid Cooled 540–675 Vdc Liquid Cooled Inverter Units, continued Drives Drive Output**
|**Current**<br>**Thermal**|**Rated Cont.**|**Rated Cont.**|**Motor Output Power**<br>**Optimum Motor**|**Optimum Motor**|**Power Loss**<br>**c/a/T**|||
|---|---|---|---|---|---|---|---|
|**Ith(A)**<br>650|**IL (A)**<br>591|**IH (A)**<br>433|**at Ith400V (kW)**<br>355|**at Ith500V (kW)**<br>450|**(kW)**<br>8.5/0.6/**9.1**|**Chassis**<br>CH62|**Catalog Number**<br>**LCX650A0-4A7N2**|
|730|664|487|400|500|10.0/0.7/**10.7**|CH62|**LCX730A0-4A7N2**|
|820|745|547|450|560|12.5/0.8/**13.3**|CH63|**LCX820A0-4A7N2**|
|920|836|613|500|600|14.4/0.9/**15.3**|CH63|**LCX920A0-4A7N2**|
|1030|936|687|560|700|16.5/1.0/**17.5**|CH63|**LCXH10A0-4A7N2**|
|1150|1045|766|600|750|18.4/10.1/**19.5**|CH63|**LCXH11A0-4A7N2**|
|1370<br>1640|1245<br>1491|913<br>1093|700<br>900|900<br>1100|15.5/1.0/**16.5**<br>19.5/1.2/**20.7**|CH64<br>CH64|**LCXH13A0-4A7N2**<br>**LCXH16A0-4A7N2**|
|2060|1873|1373|1100|1400|26.5/1.5/**28.0**|CH64|**LCXH20A0-4A7N2**|
|2300|2091|1533|1250|1500|29.6/1.7/**31.3**|CH64|**LCXH23A0-4A7N2**|
|2470|2245|1647|1300|1600|36.0/2.0/**38.0**|2*CH64|**LCXH24A0-4A7N2**|
|2950<br>3710|2681<br>3372|1967<br>2473|1550<br>1950|1950<br>2450|39.0/2.4/**41.4**<br>48.0/2.7/**50.7**|2*CH64<br>2*CH64|**LCXH29A0-4A7N2**<br>**LCXH37A0-4A7N2**|
|4140|3763|2760|2150|2700|53.0/3.0/**66.0**|2*CH64|**LCXH41A0-4A7N2**|
**2**
## **710–930 Vdc Liquid Cooled Inverter Unit**
|**Drive Output**||||||||
|---|---|---|---|---|---|---|---|
|**Current**|||**Motor Output Power**||**Power Loss**|||
|**Thermal**<br>**Ith(A)**|**Rated Cont.**<br>**IL (A)**|**Rated Cont.**<br>**IH (A)**|**Optimum Motor**<br>**at Ith400V (kW)**|**Optimum Motor**<br>**at Ith500V (kW)**|**c/a/T**<br>**(kW)**|**Chassis**|**Catalog Number**|
|170|155|113|110|160|4.5/0.2/**4.7**|CH61|**LCX170A0-5A7N2**|
|208|189|139|132|200|5.5/0.3/**5.8**|CH61|**LCX208A0-5A7N2**|
|261|237|174|160|250|5.5/0.3/**5.8**|CH61|**LCX261A0-5A7N2**|
|325|295|217|200|300|6.5/0.3/**6.8**|CH62|**LCX325A0-5A7N2**|
|385|350|257|250|355|7.5/0.4/**7.9**|CH62|**LCX385A0-5A7N2**|
|416<br>460|378<br>418|277<br>307|250<br>300|355<br>400|8.0/0.4/**8.4**<br>8.5/0.4/**8.9**|CH62<br>CH62|**LCX416A0-5A7N2**<br>**LCX460A0-5A7N2**|
|502|456|335|355|450|10.0/0.5/**10.5**|CH62|**LCX502A0-5A7N2**|
|590|536|393|400|560|10.0/0.5/**10.5**|CH63|**LCX590A0-5A7N2**|
|650|591|433|450|600|13.5/0.7/**14.2**|CH63|**LCX650A0-5A7N2**|
|750<br>820|682<br>745|500<br>547|500<br>560|700<br>800|16.0/0.8/**16.8**<br>16.0/0.8/**16.8**|CH63<br>CH64|**LCX750A0-5A7N2**<br>**LCX820A0-5A7N2**|
|920|836|613|650|850|18.0/0.9/**18.9**|CH64|**LCX920A0-5A7N2**|
|1030|936|687|700|1000|19.0/1.0/**20.0**|CH64|**LCXH10A0-5A7N2**|
|1180|1073|787|800|1100|21.0/10.1/**20.1**|CH64|**LCXH11A0-5A7N2**|
|1300|1182|867|900|1200|27.0/1.4/**28.4**|CH64|**LCXH13A0-5A7N2**|
|1500|1364|1000|1050|1400|32.0/1.6/**33.6**|CH64|**LCXH15A0-5A7N2**|
|1700<br>1850|1545<br>1682|1133<br>1233|1150<br>1250|1550<br>1650|N/A<br>34.2/1.8/**36.0**|CH64<br>2*CH64|**LCXH17A0-5A7N2**<br>**LCXH18A0-5A7N2**|
|2120|1927|1413|1450|1900|37.8/2.0/**39.8**|2*CH64|**LCXH21A0-5A7N2**|
|2340|2127|1560|1600|2100|48.6/2.5/**51.1**|2*CH64|**LCXH23A0-5A7N2**|
|2700|2455|1800|1850|2450|57.6/3.0/**60.6**|2*CH64|**LCXH27A0-5A7N2**|
|3100|2818|2066|2150|2800|N/A|2*CH64|**LCXH31A0-5A7N2**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-267**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
**2**
## **Options**
## **9000X Series Option Board Kits**
The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is designed to accept a total of five option boards.
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2 relay output board, which are installed in slots A and B.
## **Option Boards**
**==> picture [54 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B [C] [D] [E]<br>**----- End of picture text -----**<br>
## **Option Board Kits**
||**Option Board Kits**|||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
||||**Field**<br>**Installed**|**Factory**<br>**Installed**|**SVX Ready Programs**|||||||
||**Option Kit Description**1|**Allowed Slot**<br>**Locations**2|**Catalog**<br>**Number**|**Option**<br>**Designator**|**Basic**|**Local/**<br>**Remote**|**Standard**|**MSS**|**PID**|**Multi-P.**|**PFC**|
||**Standard I/O Cards**<br>2 RO (NC-NO)<br>6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/EXT +24 Vdc|B<br>A|**OPTA2**<br>**OPTA9**|**—**<br>**—**|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|
||**Extended I/O Cards**|||||||||||
||2 RO, therm|B|**OPTA3**|**A3**|—|■|■|■|■|■|■|
||Encoder low Volt +5V/15V/24V<br>Encoder high Volt +15V/24V|C<br>C|**OPTA4**<br>**OPTA5**|**A4**<br>**A5**|—<br>—|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|
||Dual encoder +15V/24V|C|**OPTA7**|**A7**|—|■|■|■|■|■|■|
||6 DI, 1 DO, 2 AI, 1 AO|A|**OPTA8**|**A8**|—|■|■|■|■|■|■|
||3 DI (encoder 10–24V), out +15V/+24V,<br>2 DO (pulse+direction)—SPX only|C|**OPTAE**|**AE**|■|■|■|■|■|■|■|
||6 DI, 1 ext +24 Vdc/EXT +24 Vdc|B, C,**D**, E|**OPTB1**|**B1**|—|—|—|—|—|■|■|
||1 RO (NC-NO), 1 RO (NO), 1 therm|B, C,**D**, E|**OPTB2**|**B2**|—|—|—|—|—|■|■|
||1 AI (mA isolated), 2 AO (mA isolated),|B, C,**D**, E|**OPTB4**|**B4**|—|■|■|■|■|■|■|
||1 ext +24 Vdc/EXT +24 Vdc|||||||||||
||3 RO (NO)|B, C,**D**, E|**OPTB5**|**B5**|—|—|—|—|—|■|■|
||1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100|B, C,**D**, E|**OPTB8**|**B8**|—|—|—|—|—|—|—|
||1 RO (NO), 5 DI 42–240 Vac input|B, C,**D**, E|**OPTB9**|**B9**|—|—|—|—|—|■|■|
||SPI, absolute encoder|C|**OPTBB**|**BB**|—|—|—|—|—|—|—|
||**Communication Cards**3|||||||||||
||Modbus<br>Johnson Controls N2|D,**E**<br>D,**E**|**OPTC2**<br>**OPTC2**|**C2**<br>**CA**|■<br>—|■<br>—|■<br>—|■<br>—|■<br>—|■<br>—|■<br>—|
||PROFIBUS DP|D,**E**|**OPTC3**|**C3**|■|■|■|■|■|■|■|
||LonWorks|D,**E**|**OPTC4**|**C4**|■|■|■|■|■|■|■|
||PROFIBUS DP (D9 connector)|D,**E**|**OPTC5**|**C5**|■|■|■|■|■|■|■|
||CANopen (slave)|D,**E**|**OPTC6**|**C6**|■|■|■|■|■|■|■|
||DeviceNet|D,**E**|**OPTC7**|**C7**|■|■|■|■|■|■|■|
||Modbus (D9 Type connector)<br>Modbus TCP|D,**E**<br>D,**E**|**OPTC8**<br>**OPTCI**|**C8**<br>**CI**|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|
||Adapter—SPX only<br>Adapter—SPX only|D,**E**<br>D,**E**|**OPTD1**<br>**OPTD2**|**D1**<br>**D2**|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|■<br>■|
||RS-232 with D9 connection|D,**E**|**OPTD3**|**D3**|■|■|■|■|■|■|■|
||**Keypad**|||||||||||
||9000X Series standard keypad|—|**KEYPAD-**<br>**STD**|**—**|—|—|—|—|—|—|■|
||9000X Series remote mount keypad unit<br>(keypad not included, includes 10 ft cable,|—|**OPTRMT-**<br>**KIT-9000X**|**—**|—|—|—|—|—|—|—|
||keypad holder, mounting hardware)|||||||||||
## _**Notes**_
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
3 OPTC2 is a multi-protocol option card.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-268**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
## **Line Reactors**
The line reactor carries out several functions in the liquid cooled drive. Connection of the line reactor is necessary except if you have a component in your system that performs the same tasks (e.g. a transformer). The line
reactor is needed as an essential component for motor control, to protect the input and DC-link component against abrupt changes of current and voltage as well as to function as a protection
against harmonics. The line reactors are included in the standard delivery of liquidcooled drives (not inverters). However, you can also order your drive without a line reactor.
**2**
## **Line Reactor Specifications**
|||**Thermal**|**Nominal**|**Calculated**|**Choke**|
|---|---|---|---|---|---|
|**Drive Rating**|**Drive Rating**|**Current**|**Inductance**|**Loss**|**Catalog Number**|
|**480V**|**690V**|**(A)**|**(μH) A/B**1|**(W)**|**(690 Vac)**|
|16 to 22A|12 to 23A|23|1900|145|**CHK0023N6A0**|
|31 to 38A|31 to 38A|38|1100|170|**CHK0038N6A0**|
|45 to 61A|46 to 62A|62|700|210|**CHK0062N6A0**|
|72 to 87A|72 to 87A|87|480|250|**CHK0087N6A0**|
|105 to 140A|105 to 140A|145|290|380|**CHK0145N6A0**|
|168 to 261A|170 to 261A|261|139/187|460|**CHK0261N6A0**|
|300 to 385A|325 to 385A|400|90/126|570|**CHK0400N6A0**|
||820 to 1180A2|||||
|460 to 520A|416 to 502A|520|65/95|610|**CHK0520N6A0**|
|1370A2|1300 to 1500A2|||||
|590 to 650A|590 to 650A|650|51/71|840|**CHK0650N6A0**|
|1640A2||||||
|730A|—|730|45/61|850|**CHK0730N6A0**|
|2060A2||||||
|820A|750A|N/A|N/A|N/A|**CHK0820N6A0**|
|2300A2||||||
|920 to 1030A|—|1000|30/41|950|**CHK1030N6A0**|
|1150A|—|1150|26/36|1000|**CHK1150N6A0**|
|**Dimensions**, see**Page V6-T2-273**.||||||
## _**Notes**_
> 1 Inductances for different supply voltages: A = 400–480 Vac; B = 500–690 Vac.
> 2 Drives require three chokes of the designated catalog number with six-pulse supply.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-269**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
## **Technical Data and Specifications**
|**2**|**Technical Data and**|**Specifications**|
|---|---|---|
|**2**|**LCX9000 Products**||
||**Description**|**Specification**|
|**2**|**General Specifications**||
|**2**|Line voltage|400 to 500 Vac; 525 to 690 Vac; (–10% to 10%)<br>465 to 800 Vdc; 640 to 1100 Vdc; (–0 to 0%)|
||Frequency|50/60 Hz|
|**2**|Line voltage variation|–10% to 10%|
|**2**|Input frequency variation<br>Continuous output current|45–66 Hz<br>Rated current at incoming cooling liquid|
|**2**|Output frequency|temperature of 30°C<br>0–320 Hz|
|**2**|Drive efficiency|>95%|
||Power factor (displacement)|0.96|
|**2**|Liquid coolant pressure|87 psi (6 bar) maximum|
||Liquid coolant flow rate|1.3 to 7.9 gal./min. (5 to 30 liter/min.)|
|**2**||minimum depending on drive size|
||Liquid coolant fittings|Standard quick connect, NPT|
|**2**|Operating ambient temperature|–10/50°C|
|**2**|Storage temperature<br>Humidity|–40/70°C<br>95% maximum (non-condensing)|
|**2**|Altitude|3300 ft (1000 m) maximum without derating|
||Enclosure|IP00|
|**2**|Warranty|Standard terms, 3 years with certified start-up|
||**Mains Connection**||
|**2**|Input voltage (Vin)|400–500 Vac; 525–690 Vac; (–10%–10%)|
|||465–800 Vdc; 640–1100 Vdc; (–0–0%)|
|**2**|Input frequency (fin)|45–66Hz|
|**2**|Connection to mains<br>**Motor Connection**|Once per minute or less (normal case)|
|**2**|Output voltage|0–Vin|
||Continuous output current|Rated current at nominal inflow cooling water|
|**2**|Starting current|temperature of 30°C; Overload 2 sec./20 sec.<br>Rated current at 2 sec./20 sec. if output frequency|
|**2**|Output frequency|<30 Hz and temperature of heatsink <149°F (65°C)<br>0–320 Hz (standard); 7200 Hz (special software)|
|**2**|Frequency resolution|Application dependent|
||**Control Characteristics**||
|**2**|Control method|Frequency control (V/f)|
|||Open loop: Sensorless vector control|
|**2**||Closed loop: Frequency control<br>Closed loop: Vector control|
|**2**|Switching frequency<br>480V1|Adjustable with parameter 2.6.9<br>Up to and including 61-Amp size:|
|||1–16 kHz (factory default, 10 kHz)|
|**2**||From 72-Amp size:<br>1–12 kHz (factory default, 3.6 kHz)|
|**2**|575V1|1–6kHz (factory default, 1.5kHz)|
||Frequency reference|Analog input: resolution 0.1% (10 bits); accuracy ±1%|
|**2**||Panel reference: resolution 0.01 Hz|
||Field weakening point|30–320 Hz|
|**2**|Acceleration time|0.1–3000 seconds|
||Deceleration time|0.1–3000 seconds|
|**2**|Braking torque|DC brake: 30% x Tn(without brake option)|
|**Description**|**Specification**|
|---|---|
|**Ambient Conditions**||
|Ambient operating temperature|14°F (–10°C), no frost to 122°F (50°C) at Ith|
||122 to 158°F (50 to 70°C), derating required|
|Storage temperature|–40°F to 158°F (–40 to 70°C)|
||No liquid in heatsink under 32°F (0°C)|
|Relative humidity|5–96% RH, noncondensing, no dripping water|
|Air quality|Chemical vapors:|
||IEC 721-3-3, unit in operation, class 3C2|
||Mechanical particles:|
||IEC 721-3-3, unit in operation, class 3S2 (no conductive|
||dust allowed); No corrosive gases|
|Altitude|Up to 1,000m: 100% load capacity (no derating)|
||Above 1,000m: Derating of 1% per each 100m required|
|Vibration|EN 50178, EN 60068-2-6; 5–150 Hz|
||Displacement amplitude: 0.25 mm (peak) at 3–31 Hz|
||Max. acceleration amplitude: 1G at 31–150 Hz|
|Shock|EN 50178, EN 60068-2-27, UPS drop test|
||(for applicable UPS weights)|
||Storage and shipping: Max. 15G, 11 ms (in package)|
|Enclosure class|IP00 open frame standard in entire kW/hp range|
|**EMC**||
|Immunity|Fulfils all EMC immunity requirements|
|Emissions|EMC level N; EMC level T for IT networks|
|**Safety**||
|Approvals|EN 50178, EN 60204-1, CE, UL, CUL, FI,|
||GOST R, IEC 61800-5|
||(See unit nameplate for more detailed approvals.)|
|**Control Connections**||
|Analog input voltage|0 to +10V, Ri= 200 kohm (–10V to +10V joystick control)|
||Resolution 0.1%; accuracy ±1%|
|Analog input current|0(4)–20 mA, Ri= 250 ohm differential|
|Digital inputs|6 positive or negative logic; 18–24 Vdc|
|Auxiliary voltage|+24V, ±15%, max. 250 mA|
|Output reference voltage|+10V, +3%, max. load 10 mA|
|Analog output|0(4)–20 mA, RLmax. 500 ohm|
||Resolution 10 bits; accuracy ±2%|
|Digital outputs|Open collector output, 50 mA/48V|
|Relay outputs|Two programmable change-over relay outputs|
||Switching capacity: 24 Vdc/8A, 250 Vac/8A,|
||125 Vdc/0.4A|
||Min. switching load: 5V/10 mA|
|**_Note_**||
|1 Derating required if higher switching frequency than the default is used.||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-270**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
## **LCX9000 Products, continued**
|**Description**|**Specification**|
|---|---|
|**Protections**||
|Overvoltage protection||
|480V|911V|
|575V<br>Undervoltage protection|1200V|
|480V<br>575V|333V<br>461V|
|Ground fault protection|In case of ground fault in motor or motor cable,<br>only the drive is protected|
|Mains supervision<br>Motor phase supervision<br>Unit overtemperature protection|Trips if any of the input phases are missing (drives only)<br>Trips if any of the output phases are missing|
|Alarm limit<br>Trip limit|149°F (65°C) for heatsink, 158°F (70°C) for circuit boards<br>158°F (70°C) for heatsink, 185°F (85°C) for circuit boards|
|**Description**|**Specification**|
|---|---|
|**Protections, continued**||
|Overcurrent protection|Yes|
|Motor overload protection|Yes|
|Motor stall protection<br>Motor underload protection|Yes<br>Yes|
|Short-circuit protection|Yes (+24V and +10V reference voltages)|
|**Liquid Cooling**||
|Allowed cooling agents|Drinking water|
||Water-glycol mixture|
|Temperature of cooling agent|32 to 86°F (0 to 30°C) at Ithfor input;<br>86 to 149°F (30 to 65°C)|
||Max. temperature rise during circulation: 9°F (5°C), no<br>condensation allowed|
|System max. working pressure<br>System max. peak pressure|87 psi (6 bar)<br>580 psi (40 bar)|
|Pressure loss (at nominal flow)|Varies according to size|
**2**
## **Wiring Diagrams Cooling System Diagrams**
**Example of a Typical Cooling System**
**==> picture [155 x 32] intentionally omitted <==**
**==> picture [227 x 219] intentionally omitted <==**
**----- Start of picture text -----**<br>
30.0C 18.0C<br>Heat<br>Exchanger<br>35.4C 26.1C<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-271**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
## **Example PI-Diagram of a Typical Cooling System and Connections**
**==> picture [532 x 194] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cooling Water Inlet<br>2 Frequency<br>Converters<br>2<br>2<br>2<br>2<br>Cooling Water Outlet<br>2<br>2<br>2<br>Customer Delivery<br>2<br>**----- End of picture text -----**<br>
## **I/O Board Diagrams**
## **A9 Option Board Control Wiring**
**==> picture [300 x 312] intentionally omitted <==**
**----- Start of picture text -----**<br>
Basic I/O Board A9<br>+10 V ref 1<br>AI1+ 2 Reference<br>(voltage)<br>GND 3<br>AI2+ 4<br>Reference<br>AI2- 5 (current)<br>24Vout 6 Control Voltage Output<br>GND 7<br>DIN1 8<br>DIN2 9<br>DIN3 10 24V<br>GND<br>CMA 11<br>24Vout 12<br>GND 13<br>DIN4 14<br>DIN5 15<br>DIN6 16 24V<br>GND<br>CMB 17<br>AO1 [+] 18 0 (4)/20mA<br>AO1 [-] 19 RL<500W<br>DO1 20 + V<+48V<br>I<50mA<br>**----- End of picture text -----**<br>
Dotted lines indicate the connections for inverted signals
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-272**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
## **A2 Option Board Wiring**
**==> picture [287 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
Basic Relay Board A2<br>RO1/1 21<br>RO1/2 22<br>R L<br>RO1/3 23 AC / DC<br>RO2/1 24 Switching:<br><8 A / 24 Vdc<br>RO2/2 25 <0.4 A / 125 Vdc<br><8 A / 250 Vac<br>RO2/3 26<br><2 Arms<br>Continuous<br>**----- End of picture text -----**<br>
**2**
## **Dimensions**
Approximate Dimensions in Inches (mm)
## **Line Reactors**
## **Sizes Up To 61A**
## **Sizes Larger Than 61A**
**==> picture [407 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
Z W Y V X U Mains<br>H1<br>H1<br>W1<br>D1<br>Converters<br>W1 D1<br>**----- End of picture text -----**<br>
|||||**Weight**|
|---|---|---|---|---|
|**Catalog Number**|**H1**|**W1**|**D1**|**Lbs (kg)**|
|**CHK0023N6A0**|7.01 (178)|9.06 (230)|4.76 (121)|22 (10)|
|**CHK0038N6A0**|8.23 (209)|10.63 (270)|5.71 (145)|33 (15)|
|**CHK0062N6A0**|8.39 (213)|11.81 (300)|6.30 (160)|44 (20)|
|**CHK0087N6A0**|9.13 (232)|11.81 (300)|6.69 (170)|57 (26)|
|**CHK0145N6A0**|11.50 (292)|11.81 (300)|7.28 (185)|82 (37)|
|**CHK0220N6A0**|12.05 (306)|13.86 (352)|7.28 (185)|119 (54)|
|**CHK0325N6A0**|13.66 (347)|13.86 (352)|7.28 (185)|132 (60)|
|**CHK0460N6A0**|16.54 (423)|13.70 (348)|9.41 (239)|203 (92)|
|**CHK0520N6A0**|17.60 (447)|15.51 (394)|10.71 (272)|231 (105)|
|**CHK0590N6A0**|20.43 (519)|15.51 (394)|10.71 (272)|276 (125)|
|**CHK0650N6A0**|20.51 (521)|15.51 (394)|10.71 (272)|276 (125)|
|**CHK0750N6A0**|24.72 (628)|15.51 (394)|11.10 (282)|331 (150)|
|**CHK0820N6A0**|24.72 (628)|15.51 (394)|11.10 (282)|331 (150)|
|**CHK1000N6A0**|22.68 (576)|19.57 (497)|11.85 (301)|441 (200)|
|**CHK1150N6A0**|22.83 (580)|19.57 (497)|11.85 (301)|441 (200)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-273**
Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives
## 2.9
Approximate Dimensions in Inches (mm)
## **LCX9000 Drives**
**2**
## **Chassis Size, CH3**
|H|W2<br>W1<br>2|W2<br>W1<br>2||||**W1**<br>**W2**<br>**W3**<br>**R1 Dia.**<br>**R2 Dia.**<br>**Weight**<br>**Lbs (kg)**<br>**Bottom**<br>**Top**|
|---|---|---|---|---|---|---|
|H1|||||||
|||W3||D1|||
|**oltage**<br>H|||**H2**||||
|80–500 Vac<br>16–61<br>16.97<br>(431.0)|||0.<br>(1|53<br>3.5)<br>0.59<br>(15.0)<br>9.69<br>(246.0)||6.30<br>(160.0)<br>4.80<br>(122.0)<br>4.80<br>(122.0)<br>0.39<br>(10.0)<br>0.35<br>(9.0)<br>66 (30)|
## **Chassis Size, CH4**
**==> picture [504 x 244] intentionally omitted <==**
**----- Start of picture text -----**<br>
W1<br>H2 R1<br>W2<br>H1 Top<br>H3<br>W3 R1 D1<br>Bottom<br>Right Side Front Left Side<br>Weight<br>Voltage Amps H1 H2 H3 D1 W1 W2 W3 R1 Dia. R2 Dia. Lbs (kg)<br>380–500 Vac 72–140 19.41 0.49 1.77 10.14 7.60 3.35 5.24 0.39 — 77 (35)<br>(493.0) (12.5) (45.0) (257.5) (193.0) (85.0) (133.0) (10.0)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-274**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
Approximate Dimensions in Inches (mm)
## **Chassis Size, CH5**
**==> picture [505 x 265] intentionally omitted <==**
**----- Start of picture text -----**<br>
W1<br>W2 R1<br>H1 H3 Top<br>H2<br>W3 R1 D1 Bottom<br>Front Side<br>Weight<br>Voltage Amps H1 H2 H3 D1 W1 W2 W3 R1 Dia. R2 Dia. Lbs (kg)<br>380–500 Vac 168–261 21.77 1.30 19.88 10.39 9.69 3.94 7.87 0.51 — 88 (40)<br>(553.0) (33.0) (505.0) (264.0) (246) (100.0) (200.0) (13.0)<br>**----- End of picture text -----**<br>
**2**
## **Chassis Size, CH61**
|**Amps**<br>**H1**<br>**ttom**<br>**p**|||||||**D1**<br>**W**<br>R2<br>H2<br>H3||**1**<br>**W2**<br>**W3**<br>W3<br>**Front**<br>W2<br>W1<br>H1<br>R1||**R1 Dia.**<br>**R2 Dia.**<br>**Weight**<br>**Lbs (kg)**<br>D1<br>**Left Side**|
|---|---|---|---|---|---|---|---|---|---|---|---|
|||||||||2<br>3||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||||||||||||
|||**H2**<br>**H3**<br>**Right Side**||||||||||
|ac<br>300–385<br>25.91<br>(658.0)<br>ac<br>170–208||2.09<br>(53.0)<br>23.23<br>(590.0)|||||14.69<br>(373.0)<br>9.<br>(2||69<br>46.0)<br>3.94<br>(100.0)<br>5.91<br>(150.0)||0.55<br>(14.0)<br>0.51<br>(13.0)<br>121 (55)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-275**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
Approximate Dimensions in Inches (mm)
**2**
## **Liquid-Cooled Inverter—Chassis Size, CH62**
**==> picture [460 x 257] intentionally omitted <==**
**----- Start of picture text -----**<br>
W1<br>R2 W2<br>Top<br>H1 H3<br>H2<br>D1 W3 R1<br>Bottom Side Front<br>Voltage Amps H1 H2 H3 D1 W1 W2 W3 R1 Dia. R2 Dia.<br>540–675 Vdc 460–730 26.50 2.0 23.23 14.69 9.69 3.94 5.91 0.55 0.51<br>(673) (53) (590) (373) (246) (100) (150) (14) (13)<br>710–930 Vdc 325–502<br>**----- End of picture text -----**<br>
## **Chassis Size, CH63**
**==> picture [504 x 278] intentionally omitted <==**
**----- Start of picture text -----**<br>
H2<br>H3 H1<br>Top<br>R1<br>W2 D1<br>W1<br>Bottom<br>Right Side Front Left Side<br>Weight<br>Voltage Amps H1 H2 H3 D1 W1 W2 R1 Dia. Lbs (kg)<br>380–500 Vac 820–1030 36.36 0.91 34.39 15.35 19.88 13.98 0.43 264 (120)<br>(923.5) (23.0) (873.5) (390.0) (505.0) (355.0) (11.0)<br>525–690 Vac 590–750<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-276**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
Approximate Dimensions in Inches (mm)
**Liquid-Cooled Inverter with Mounting Bracket, Chassis Size CH64, IP90**
**==> picture [25 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Bottom<br>**----- End of picture text -----**<br>
**==> picture [13 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Top<br>**----- End of picture text -----**<br>
**2**
||**H3**<br>**D1**<br>**W1**<br>**W2**<br>**R1 Dia.**<br>H1<br>H3<br>H2<br>W2<br>D1<br><br>Left Side<br>R1|
|---|---|
|–675 Vdc<br>1370–4140<br>36.38<br>(924)<br>1.03<br>(26)<br>–930 Vdc<br>820–3100|34.37<br>(873)<br>15.35<br>(390)<br>29.37<br>(746)<br>7.87<br>(200)<br>0.43<br>(11)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-277**
Adjustable Frequency Drives
LCX9000 Liquid Cooled Drives
## 2.9
Approximate Dimensions in Inches (mm)
**Chassis Size, CH72**
|**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br>**2**<br> <br>**Vol**<br>380<br>525||<br>**Amps**<br>**H1**<br>H2<br>**om**|||W1||**D1**<br>**W1**<br>**R1 Dia.**<br>**R2 Dia.**<br>**Weight**<br>**Lbs (kg)**<br>D1<br>**Side**|
|---|---|---|---|---|---|---|---|
|||||||||
|||||||||
|||||||||
||Top|||||||
||**tage**<br>**Bott**|||||||
|||||||||
||||||W1<br>**Front**|||
||–500 Vac|460–730<br>42.38<br>(1076.5)<br>261–502||||1.57<br>(40.0)<br>39.37<br>(1000.0)|14.65<br>(372.0)<br>7.87<br>(200.0)<br>0.55<br>(14.0)<br>0.51<br>(13.0)<br>198 (90)|
||–690 Vac|||||||
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-278**
Adjustable Frequency Drives
2.9
LCX9000 Liquid Cooled Drives
Approximate Dimensions in Inches (mm)
## **Chassis Size, CH74**
**==> picture [505 x 364] intentionally omitted <==**
**----- Start of picture text -----**<br>
R2<br>Top<br>H1 H3<br>Bottom<br>H2<br>W2 W3 R1 D1<br>W4 W4<br>W1<br>Front Side<br>Weight<br>Voltage Amps H1 H2 H3 D1 W1 W2 W3 W4 R1 Dia. R2 Dia. Lbs (kg)<br>380–500 Vac 1370–2300 42.38 1.57 39.37 14.65 29.06 0.91 7.87 9.69 0.51 0.55 617 (280)<br>(1076.5) (40.0) (1000.0) (372.0) (738.0) (23.0) (200.0) (246) (13.0) (14.0)<br>525–690 Vac 820–1500<br>**----- End of picture text -----**<br>
**2**
## **Control Unit**
**==> picture [269 x 189] intentionally omitted <==**
**----- Start of picture text -----**<br>
D1<br>D2<br>H2<br>H1 H3<br>Bottom<br>W1<br>Front Side Back<br>H1 H2 H3 D1 D2 W1<br>12.93 0.33 11.81 2.95 0.33 5.75<br>(328.5) (8.5) (300.0) (75.0) (8.5) (146.0)<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-279**
Adjustable Frequency Drives
2.10
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
**2**
## **SPA9000/SPN9000/SPI9000 Common DC Bus Drive Products**
## **Contents**
|**Contents**||
|---|---|
|**_Description_**|**_Page_**|
|SPA9000/SPN9000/SPI9000 Common DC Bus Drives|SPA9000/SPN9000/SPI9000 Common DC Bus Drives|
|Application Description . . . . . . . . . . . . . . . . . .|**V6-T2-281**|
|Product Comparison . . . . . . . . . . . . . . . . . . . .|**V6-T2-281**|
|Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-282**|
|Standards and Certifications . . . . . . . . . . . . . .|**V6-T2-282**|
|Catalog Number Selection . . . . . . . . . . . . . . . .|**V6-T2-282**|
|Product Selection . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-284**|
|Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-287**|
|Technical Data and Specifications . . . . . . . . . .|**V6-T2-288**|
|Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-290**|
|Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .|**V6-T2-291**|
## **Product Description**
Eaton offers a comprehensive range of common DC bus drive products. The product family covers a number of front-end units and inverter units in the entire power range from 1-1/2 to 2000 horsepower at 460V and 690V. The drive components are built on the SPX9000 technology.
## **Front-End Units**
The front-end units convert a mains AC voltage and current into a DC voltage and current. The power is transferred from the mains to a common DC bus (and, in certain cases, vice versa).
The SPA (active front-end) unit is a bidirectional (regenerative) power converter for the front end of a common DC bus drive line up. An external LCL filter is used at the input. This unit is suitable in applications where low mains harmonics are required.
The SPN (non-regenerative front-end) unit is a unidirectional (motoring) power converter for the front-end of a common DC bus drive line-up. The device operates as a diode bridge using diode/ thyristor components. A dedicated external choke is used at the input. The unit has the capacity to charge a common DC bus. This unit is suitable as a rectifying device when a “normal” level of harmonics is accepted and no regeneration to the mains is required.
## **Inverter Unit**
The SPI9000 Inverter Unit is a bidirectional DC-fed power inverter for the supply and control of AC motors. The inverter is supplied from a common DC bus drive lineup. A charging circuit is needed in case a connection to a live DC bus is required. The DC side charging circuit is integrated up to 75 kW (FR4–FR8) and external for higher power ratings (FI9–FI14).
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-280**
Adjustable Frequency Drives
2.10
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## **Application Description**
The common DC bus product portfolio fulfills all solution demands with a flexible architecture.
Front end units are selected according to the level of harmonics and power requirements. Typical drive system configurations are illustrated the following figures.
## **SPA + Inverters**
## **SPN + Inverters Combination Configuration**
**2**
**==> picture [431 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
Active Non-regenerative Non-regenerative Active<br>Front End Front End Front End Front End<br>(SPA) (SPN) (SPN) Alternative (SPA) Alternative<br>3 3 3 3<br>2 2 2 2<br>Common DC Bus<br>2 2 2 2 2 2 2 2<br>3 3 3 3 3 3 3 3<br>Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter<br>● Low harmonics, -Pmains ● Low total mains power, Common DC bus<br>~~ +Pmains/Pmains < PINU Pmains < PINU components are used in a<br>multitude of combinations.<br>● Suitable for almost every ● Suitable e.g. for small<br>Drives which are braking can<br>application processing line with<br>transfer the energy directly to<br>un- and recoiler, em-stop<br>the drives in motoring mode.<br>coasting<br>**----- End of picture text -----**<br>
## **Product Comparison**
## **Advantages over Conventional Front Ends**
## **Eaton Front Ends vs. Conventional**
||**Non-Regenerative**|**Active**|**Conventional**|
|---|---|---|---|
||**Front End**|**Front End**|**Regenerative Front End**1|
|Input device|Choke (L)|Filter (LCL)|Choke or auto-transformer (L)|
|Bridge type|Diode/thyristor bridge|IGBT bridge, two-level type|Anti-parallel connected thyristor bridge|
|Type of operation|Controlled half-bridge|High frequency modulation|Firing angle controlled|
|||(1.5 to 3.6 kHz)||
|Direction of power|Motoring|Motoring and regenerating|Motoring and regenerating|
|Charging|Constant current|External required|Usually internal|
|DC voltage|Nominal (approx. 1.35|Stable at +10% of nominal|Lowered DC voltage for commutation margin|
||alternative UN)|(approx. 110% of 1.35|(e.g. 17% fi approx. 83% of 1.35 alternative UN) or|
|||alternative UN)|autotransformer on regenerative bridge|
|THD|Similar to six-pulse bridge|Very low|Similar to six-pulse bridge or worse|
||normal <40%|||
## _**Note**_
> 1 Conventional regenerative front end (a.k.a. “anti-parallel thyristor bridge”) is not available from Eaton.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-281**
Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## 2.10
## **Features**
**2**
## **Standard Features**
|**Standard Features**||||||
|---|---|---|---|---|---|
||**SPI9000**|||**SPA**|**SPN**|
|**Feature**|**FR4, 6, 7**|**FR8**|**FI9–FI14**|**FI9–FI14**|**FI9**|
|IP00|—|■|■|■|■|
|IP21|■|—|—|—|—|
|Air cooling<br>Standard board|■<br>■|■<br>■|■<br>■|■<br>■|■|
|Varnished board|—|—|—|—|—|
|Alphanumeric keypad|■|■|■|■|—|
|EMC class T (EN 61800-3 for IT networks)|■|■|■|■|■|
|Safety CE/UL|■|■|■|■|■|
|Input choke|—|—|—|—|■|
|LCL filter<br>No integrated charging|—<br>—|—<br>—|—<br>■|■<br>■|—<br>—|
|Integrated charging (DC side)|■|■|—|—|■|
|Diode/thyristor rectifier|—|—|—|—|■|
|IGBT|■|■|■|■|—|
## **Standards and Certifications**
- CE
- UL
- cUL
- EN 61800-5-1 (2003)
## **Catalog Number Selection**
## **Active Front End**
**==> picture [404 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
–<br>SPA 205 A 0 4 A 3 N 1<br>Product Family Board Modifications<br>SPA = Active Front End 1 = Standard boards<br>2 = Varnished boards<br>Current Rating<br>480V 575V Brake Chopper Options<br>205 = 205A 125 = 125A N = No brake chopper circuit<br>385 = 385A 325 = 325A<br>H10 = 1150A 920 = 920A<br>EMC Level<br>3 = IT network<br>Software Series<br>A = Standard<br>Keypad<br>A = Alphanumeric<br>Enclosure Rating Voltage Rating<br>0 = Chassis 4 = 480V<br>5 = 575V<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-282**
Adjustable Frequency Drives
2.10
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## **Non-Regenerative Front End**
**==> picture [376 x 196] intentionally omitted <==**
**----- Start of picture text -----**<br>
–<br>SPN 510 A 0 4 A 3 N 1<br>Product Family Board Modifications<br>SPN = Non-regenerative 1 = Standard boards<br>SPN = front end 2 = Varnished boards<br>Current Ratin g Brake Chopper Options<br>480V/575V N = No brake chopper circuit<br>510 = 510A<br>EMC Level<br>Software Series 3 = IT network<br>A = Standard<br>Keypad<br>A = Alphanumeric<br>Enclosure Rating<br>0 = Chassis Voltage Rating<br>4 = 480V<br>5 = 575V<br>**----- End of picture text -----**<br>
**2**
## **SPI9000 Inverter Unit**
**==> picture [462 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
–<br>SPI 016 A 1 4 A 3 N 1<br>Product Family Board Modifications<br>SPI = Inverter unit 1 = Standard boards<br>2 = Varnished boards<br>Current Rating<br>480V (FR4–FR8) 575V (FR6–FR8) Brake Chopper Options<br>003 = 3.3A 031 = 31A 003 = 3.2A 022 = 22A N = No brake chopper circuit<br>007 = 7.6A 038 = 38A 004 = 4.5A 027 = 27A<br>009 = 9A 061 = 61A 005 = 5.5A 034 = 34A<br>012 = 12A 071 = 72A 007 = 7.5A 041 = 41A EMC Level<br>016 = 16A 087 = 87A 010 = 10A 052 = 52A 3 = IT network<br>023 = 23A 105 = 105A 013 = 13.5A 062 = 62A<br>018 = 18A 080 = 80A<br>480V (FI9–FI13) 575V (FI9–FI14) Keypad<br>140 = 140A 730 = 730A 100 = 100A 502 = 502A A = Alphanumeric<br>170 = 170A 820 = 820A 125 = 125A 590 = 590A<br>205 = 205A 920 = 920A 144 = 144A 650 = 650A<br>245 = 245A H10 = 1030A 170 = 170A 820 = 820A Voltage Rating<br>300 = 300A H11 = 1150A 208 = 207A 920 = 920A 4 = 480V<br>385 = 385A H13 = 1300A 261 = 261A H10 = 1030A 5 = 575V<br>460 = 460A H16 = 1600A 325 = 325A H13 = 1300A<br>520 = 520A H19 = 1940A 385 = 385A H15 = 1500A Enclosure Rating<br>590 = 590A H23 = 2300A 460 = 460A H19 = 1900A<br>1 = NEMA Type 1/IP21<br>650 = 650A<br>0 = Chassis<br>Software Series<br>A = Standard<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-283**
Adjustable Frequency Drives
2.10
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## **Product Selection**
**2 Common DC Bus Drive SPA9000 Active Front End 480V Products**
||**Low Overload (AC Current)**|**Low Overload (AC Current)**|**High Overload (AC Current)**|**High Overload (AC Current)**|**Imax**||
|---|---|---|---|---|---|---|
|**Frame**|**IL-cont (A)**|**I1min (A)**|**IH-cont (A)**|**I1min (A)**|**I2s (A)**|**Catalog Number**|
|FI9|261|287|205|308|349|**SPA205A0-4A3N1**|
|FI10|460|506|385|578|693|**SPA385A0-4A3N1**|
|FI13|1300|1430|1150|1725|2070|**SPAH11A0-4A3N1**|
## **SPN9000 Non-Regenerative Front End 480V**
||**Low Overload (AC Current)**|**Low Overload (AC Current)**|**High Overload (AC Current)**|**High Overload (AC Current)**|**Imax**||
|---|---|---|---|---|---|---|
|**Frame**|**IL-cont (A)**|**I1min (A)**|**IH-cont (A)**|**I1min (A)**|**I2s (A)**|**Catalog Number**|
|FI9|520|572|460|690|828|**SPN460A0-4A3N1**|
## **SPI9000 Inverter Unit 480V**
|**SPI9000 Inverter Unit 480V**|**SPI9000 Inverter Unit 480V**|**SPI9000 Inverter Unit 480V**|||||
|---|---|---|---|---|---|---|
||**Low Overload (AC Current)**|**Low Overload (AC Current)**|**High Overload (AC Current)**|**High Overload (AC Current)**|**Imax**||
|**Frame**|**IL-cont (A)**|**I1min (A)**|**IH-cont (A)**|**I1min (A)**|**I2s (A)**|**Catalog Number**|
|FR4|4.3|4.7|3.3|5|6.2|**SPI003A1-4A3N1**|
||9|9.9|7.6|11.4|14|**SPI007A1-4A3N1**|
||12|13.2|9|13.5|18|**SPI009A1-4A3N1**|
|FR6|16|17.6|12|18|24|**SPI012A1-4A3N1**|
||23|25.3|16|24|32|**SPI016A1-4A3N1**|
||31|34|23|35|46|**SPI023A1-4A3N1**|
||38|42|31|47|62|**SPI031A1-4A3N1**|
||46|51|38|57|76|**SPI038A1-4A3N1**|
|FR7|72|79|61|92|122|**SPI061A1-4A3N1**|
||87<br>105|96<br>116|72<br>87|108<br>131|144<br>174|**SPI072A1-4A3N1**<br>**SPI087A1-4A3N1**|
|FR8|140|154|105|158|210|**SPI105A0-4A3N1**|
|FI9|170|187|140|210|280|**SPI140A0-4A3N1**|
||205|226|170|255|336|**SPI170A0-4A3N1**|
||261|287|205|308|349|**SPI205A0-4A3N1**|
||300|330|245|379|444|**SPI245A0-4A3N1**|
|FI10|385<br>460|424<br>506|300<br>385|450<br>578|540<br>693|**SPI300A0-4A3N1**<br>**SPI385A0-4A3N1**|
||520|572|460|690|828|**SPI460A0-4A3N1**|
|FI12|590|649|520|780|936|**SPI520A0-4A3N1**|
||650|715|590|885|1062|**SPI590A0-4A3N1**|
||730|803|650|975|1170|**SPI650A0-4A3N1**|
||820|902|730|1095|1314|**SPI730A0-4A3N1**|
||920|1012|820|1230|1476|**SPI820A0-4A3N1**|
||1030|1133|920|1380|1656|**SPI920A0-4A3N1**|
|FI13|1150|1265|1030|1545|1854|**SPIH10A0-4A3N1**|
||1300|1430|1150|1720|2070|**SPIH11A0-4A3N1**|
||1450|1595|1300|1950|2340|**SPIH13A0-4A3N1**|
|FI14|1770<br>2150|1947<br>2365|1600<br>1940|2400<br>2910|2880<br>3492|**SPIH16A0-4A3N1**<br>**SPIH19A0-4A3N1**|
## _**Note**_
For filter and line reactor information, see **Page V6-T2-286** .
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-284**
Adjustable Frequency Drives
2.10
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## **SPA9000 Active Front End 575V**
|**SPA9000 Active Front End 575V**|**SPA9000 Active Front End 575V**|**SPA9000 Active Front End 575V**|**SPA9000 Active Front End 575V**|||||
|---|---|---|---|---|---|---|---|
|**SPA9000 Active Front End 575V**<br>**Common DC Bus Drive**<br>**Products**||**SPA9000 Active Front End 575V**<br>**Low Overload (AC Current)**|**SPA9000 Active Front End 575V**<br>**Low Overload (AC Current)**|**High Overload (AC Current)**|**High Overload (AC Current)**|**Imax**||
||**Frame**|**IL-cont (A)**|**I1min (A)**|**IH-cont (A)**|**I1min (A)**|**I2s (A)**|**Catalog Number**|
|eel|FI9<br>144<br>158<br>125<br>188<br>213<br>**SPA125A0-5A3N1**<br>FI10<br>385<br>424<br>325<br>488<br>585<br>**SPA325A0-5A3N1**<br>FI13<br>1030<br>1133<br>920<br>1380<br>1656<br>**SPA920A0-5A3N1**<br>~~Un~~|||||||
**2**
## **SPN9000 Non-Regenerative Front End 575V**
||**Low Overload (AC Current)**|**Low Overload (AC Current)**|**High Overload (AC Current)**|**High Overload (AC Current)**|**Imax**||
|---|---|---|---|---|---|---|
|**Frame**|**IL-cont (A)**|**I1min (A)**|**IH-cont (A)**|**I1min (A)**|**I2s (A)**|**Catalog Number**|
|FI9|600|660|510|732|888|**SPN510A0-5A3N1**|
|**SPI9000 Inverter Unit 575V**|**SPI9000 Inverter Unit 575V**|**SPI9000 Inverter Unit 575V**|||||
||**Low Overload (AC Current)**|**Low Overload (AC Current)**|**High Overload (AC Current)**|**High Overload (AC Current)**|**Imax**||
|**Frame**|**IL-cont (A)**|**I1min (A)**|**IH-cont (A)**|**I1min (A)**|**I2s (A)**|**Catalog Number**|
|FR6|4.5|5|3.2|5|6.4|**SPI003A1-5A3N1**|
||5.5|6|4.5|7|9|**SPI004A1-5A3N1**|
||7.5|8|5.5|8|11|**SPI005A1-5A3N1**|
||10|11|7.5|11|15|**SPI007A1-5A3N1**|
||13.5<br>18|15<br>20|10<br>13.5|15<br>20|20<br>27|**SPI010A1-5A3N1**<br>**SPI013A1-5A3N1**|
||22|24|18|27|36|**SPI018A1-5A3N1**|
||27|30|22|33|44|**SPI022A1-5A3N1**|
||34|37|27|41|54|**SPI027A1-5A3N1**|
|FR7|41|45|34|51|68|**SPI034A1-5A3N1**|
||52|57|41|62|82|**SPI041A1-5A3N1**|
|FR8|62<br>80|68<br>88|52<br>62|78<br>93|104<br>124|**SPI052A0-5A3N1**<br>**SPI062A0-5A3N1**|
||100|110|80|120|160|**SPI080A0-5A3N1**|
|FI9|125|138|100|150|200|**SPI100A0-5A3N1**|
||144|158|125|188|213|**SPI125A0-5A3N1**|
||170|187|144|216|245|**SPI144A0-5A3N1**|
||208|229|170|255|289|**SPI170A0-5A3N1**|
|FI10|261|287|208|312|375|**SPI208A0-5A3N1**|
||325|358|261|392|470|**SPI261A0-5A3N1**|
||385|424|325|488|585|**SPI325A0-5A3N1**|
|FI12|460|506|385|578|693|**SPI385A0-5A3N1**|
||502|552|460|690|828|**SPI460A0-5A3N1**|
||590<br>650|649<br>715|502<br>590|753<br>885|904<br>1062|**SPI502A0-5A3N1**<br>**SPI590A0-5A3N1**|
||750|825|650|975|1170|**SPI650A0-5A3N1**|
|FI13|920|1012|820|1230|1476|**SPI820A0-5A3N1**|
||1030|1133|920|1380|1656|**SPI920A0-5A3N1**|
||1180|1298|1030|1464|1755|**SPIH10A0-5A3N1**|
|FI14|1500|1650|1300|1950|2340|**SPIH13A0-5A3N1**|
||1900<br>2250|2090<br>2475|1500<br>1900|2250<br>2782|2700<br>3335|**SPIH15A0-5A3N1**<br>**SPIH19A0-5A3N1**|
## _**Note**_
For filter and line reactor information, see **Page V6-T2-286** .
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-285**
Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## 2.10
**2**
## **LCL Filters**
## **LCL Filters for Active Front End (480V)**
|**LCL Filters for Active Front End**|**(480V)**|
|---|---|
|**Amps**<br>**Catalog Number**<br>10<br>**REG 10 5 0**<br>18<br>**REG 18 5 0**<br>32<br>**REG 32 5 0**<br>48<br>**REG 48 5 0**<br>75<br>**REG 75 5 0**<br>110<br>**REG 110 5 0**<br>180<br>**REG 180 5 0**|**Amps**<br>**Catalog Number**|
||270<br>**REG 270 5 0**|
||410<br>**REG 410 5 0**|
||580<br>**REG 580 5 0**|
||840<br>**REG 840 5 0**|
||1160<br>**REG 1160 5 0**|
||1480<br>**REG 1480 5 0**|
|||
## **Line Reactor**
|**Line Reactor**||
|---|---|
|**Line Reactor for**||
|**Non-Regenerative**||
|**Front End (480/575VV)**||
|**Watts**|**Catalog**|
|**Amps**<br>**Losses**|**Number**|
|600<br>493|**CHK600**|
## **LCL Filters for Active Front End (690V)**
|**LCL Filters for Active Front End**|**(690V)**|
|---|---|
|**Amps**<br>**Catalog Number**<br>14<br>**REG 14 6 0**<br>23<br>**REG 23 6 0**<br>35<br>**REG 35 6 0**<br>52<br>**REG 52 6 0**<br>85<br>**REG 85 6 0**<br>122<br>**REG 122 6 0**<br>185<br>**REG 185 6 0**|**Amps**<br>**Catalog Number**|
||287<br>**REG 287 6 0**|
||390<br>**REG 390 6 0**|
||460<br>**REG 460 6 0**|
||620<br>**REG 620 6 0**|
||780<br>**REG 780 6 0**|
||920<br>**REG 920 6 0**|
||1180<br>**REG 1180 6 0**|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-286**
Adjustable Frequency Drives
2.10
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## **Options**
## **9000X Series Option Board Kits**
The 9000X Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your application needs. The drive’s control unit is designed to accept a total of five option boards.
**2**
The 9000X Series factory installed standard board configuration includes an A9 I/O board and an A2 relay output board, which are installed in slots A and B.
## **Option Boards**
## **Option Board Kits**
|**Option Boards**|**Option Board Kits**|
|---|---|
|A<br>B C D E|**Option Kit Description**1<br>**Allowed Slot**<br>**Locations**2<br>**Field**<br>**Installed**<br>**Factory**<br>**Installed**<br>**SVX Ready Programs**<br>**Catalog**<br>**Number**<br>**Option**<br>**Designator**<br>**Basic**<br>**Local/**<br>**Remote**<br>**Standard**<br>**MSS**<br>**PID**<br>**Multi-P.**<br>**PFC**|
||**Standard I/O Cards**|
||2 RO (NC-NO)<br>B<br>**OPTA2**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 DO, 2 AI, 1AO, 1 +10 Vdc ref,<br>2 ext +24 Vdc/EXT +24 Vdc<br>A<br>**OPTA9**<br>**—**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||**Extended I/O Cards**|
||2 RO, therm<br>B<br>**OPTA3**<br>**A3**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Encoder low volt +5V/15V24V<br>C<br>**OPTA4**<br>**A4**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Encoder high volt +15V/24V<br>C<br>**OPTA5**<br>**A5**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||Double encoder<br>C<br>**OPTA7**<br>**A7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 DO, 2 AI, 1 AO<br>A<br>**OPTA8**<br>**A8**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||3 DI (encoder 10–24V), out +15V/+24V,<br>2 DO (pulse+direction)<br>C<br>**OPTAE**<br>**AE**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||6 DI, 1 ext +24 Vdc/EXT +24 Vdc<br>B, C,**D**, E<br>**OPTB1**<br>**B1**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 RO (NC-NO), 1 RO (NO), 1 therm<br>B, C,**D**, E<br>**OPTB2**<br>**B2**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 AI (mA isolated), 2 AO (mA isolated),<br>1 ext +24 Vdc/EXT +24 Vdc<br>B, C,**D**, E<br>**OPTB4**<br>**B4**<br>—<br>■<br>■<br>■<br>■<br>■<br>■|
||3 RO (NO)<br>B, C,**D**, E<br>**OPTB5**<br>**B5**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||1 ext +24 Vdc/EXT +24 Vdc, 3 Pt100<br>B, C,**D**, E<br>**OPTB8**<br>**B8**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||1 RO (NO), 5 DI 42–240 Vac input<br>B, C,**D**, E<br>**OPTB9**<br>**B9**<br>—<br>—<br>—<br>—<br>—<br>■<br>■|
||SPI, absolute encoder<br>C<br>**OPTBB**<br>**BB**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||**Communication Cards**3|
||Modbus<br>D,**E**<br>**OPTC2**<br>**C2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Johnson Controls N2<br>D,**E**<br>**OPTC2**<br>**CA**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||Modbus TCP<br>D,**E**<br>**OPTCI**<br>**CI**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||BACnet<br>D,**E**<br>**OPTCJ**<br>**CJ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||EtherNet/IP<br>D,**E**<br>**OPTCQ**<br>**CQ**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP<br>D,**E**<br>**OPTC3**<br>**C3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||LonWorks<br>D,**E**<br>**OPTC4**<br>**C4**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||PROFIBUS DP (D9 connector)<br>D,**E**<br>**OPTC5**<br>**C5**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||CANopen (slave)<br>D,**E**<br>**OPTC6**<br>**C6**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||DeviceNet<br>D,**E**<br>**OPTC7**<br>**C7**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Modbus (D9 type connector)<br>D,**E**<br>**OPTC8**<br>**C8**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Adapter<br>D,**E**<br>**OPTD1**<br>**D1**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||Adapter<br>D,**E**<br>**OPTD2**<br>**D2**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||RS-232 with D9 connection<br>D,**E**<br>**OPTD3**<br>**D3**<br>■<br>■<br>■<br>■<br>■<br>■<br>■|
||**Keypad**|
||9000X Series local/remote keypad<br>(replacement keypad)<br>—<br>**KEYPAD-**<br>**LOC/REM**<br>**—**<br>—<br>—<br>—<br>—<br>—<br>—<br>■|
||9000X Series remote mount keypad unit<br>(keypad not included, includes 10 ft cable,<br>keypad holder, mounting hardware)<br>—<br>**OPTRMT-**<br>**KIT-9000X**<br>**—**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
||9000X Series RS-232 cable, 13 ft<br>—<br>**PP00104**<br>**—**<br>—<br>—<br>—<br>—<br>—<br>—<br>—|
## _**Notes**_
1 AI = Analog Input; AO = Analog Output, DI = Digital Input, DO = Digital Output, RO = Relay Output
- 2 Option card must be installed in one of the slots listed for that card. Slot indicated in bold is the preferred location.
- 3 OPTC2 is a multi-protocol option card.
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-287**
Adjustable Frequency Drives
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## 2.10
## **Technical Data and Specifications**
|**2**|**Technical Data and Specifications**||
|---|---|---|
|**2**|**SPA9000/SPN9000/SPI9000**||
||**Description**|**Specification**|
|**2**|**Supply Connection**||
|**2**|Input voltage Uin(AC) front end modules<br>Input voltage Uin(DC) inverter|380–500 Vac/525–690 Vac –10% to 10%<br>465–800 Vdc/640–1100 Vdc –0% to 0%, the waviness of the inverter supply voltage,|
|||formed in rectification of the electric network’s alternating voltage in basic frequency,|
|**2**||must be less than 50V peak-to-peak|
||Output voltage Uout(AC) inverter|3 ~ 0–Uin/1.4|
|**2**|Output voltage Uout(DC) active front end module|10.10 x 1.35 x Uin(factory default)|
|**2**|Output voltage Uout(DC) non-regenerative front end module<br>**Ambient Conditions**|1.35 x Uin|
|**2**|Ambient operating temperature|14 (no frost) to 122°F (–10 to 50°C): IH<br>14 (no frost) to 104°F (–10 to 40°C): IL|
|**2**|Storage temperature<br>Relative humidity|–40 to 158°F (–40 to 70°C)<br>0 to 95% RH, non-condensing, non-corrosive, no dripping water|
|**2**|Air quality||
||Chemical vapors|IEC 721-3-3, unit in operation, class 3C2|
|**2**|Mechanical particles|IEC 721-3-3, unit in operation, class 3S2|
||Altitude|100% load capacity (no derating) up to 1000m|
|**2**||1% derating for each 100m above 1000m; max. 3000m|
||Vibration|5–150 Hz|
|**2**|EN50178/EN60068-2-6|Displacement amplitude 0.25 mm (peak) at 3–15.8 Hz|
|||Max acceleration amplitude 1G at 15.8–150 Hz|
|**2**|Shock|UPS Drop Test (for applicable UPS weights)|
||EN50178, EN60068-2-27|Storage and shipping: max 15G, 11 ms (in package)|
|**2**|Cooling capacity required|Approximately 2%|
||Cooling air required|FR4 41 cfm, FR6 250 cfm, FR7 250 cfm, FR8 383 cfm|
|**2**||FI9 677 cfm, FI10 824 cfm, FI12 1648 cfm, FI13 2472 cfm|
||Unit enclosure class|FR4–FR7 NEMA Type 1/IP21; FR8, FI9–FI14 chassis (IP00)|
|**2**|**EMC (at fault settings)**||
|**2**|Immunity<br>**Safety**|Fulfill all EMC immunity requirements|
|**2**|Approvals|CE, UL, cUL, EN 61800-5-1 (2003), see unit nameplate for more detailed approvals|
||**Control Connections**||
|**2**|Analog input voltage|0–10V, Ri= 200 kohms, (–10V to 10V joystick control)|
|||Resolution 0.1%, accuracy ±1%|
|**2**|Analog input current|0(4)–20 mA, Ri= 250 ohms differential|
||Digital inputs|6, positive or negative logic; 18–30 Vdc|
|**2**|Auxiliary voltage|+24V, ±15%, max. 250 mA|
|**2**|Output reference voltage<br>Analog output|+10V, +3%, max. load 10 mA<br>0(4)–20 mA; RL max. 500 ohms; resolution 10 bits|
|**2**|Digital outputs|Accuracy ±2%<br>Open collector output, 50 mA/48V|
|**2**|Relay outputs|2 programmable change-over relay outputs<br>Switching capacity: 24 Vdc/8A, 250 Vac/8A, 125 Vdc/0.4A|
|||Min. switching load: 5V/10 mA|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-288**
Adjustable Frequency Drives
2.10
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
**2**
## **SPA9000/SPN9000/SPI9000, continued**
|**Description**|**Specification**|
|---|---|
|**Protections**||
|Overvoltage protection|480V/911 Vdc, 575V/1200 Vdc|
|Undervoltage protection|480V/333 Vdc, 575V/460 Vdc|
|Ground fault protection|In case of ground fault in motor or motor cable, only the inverter is protected|
|Motor phase supervision|Trips if any of the output phases is missing|
|Overcurrent protection|Yes|
|Unit overtemperature protection|Yes|
|Motor overload protection|Yes|
|Motor stall protection|Yes|
|Motor underload protection|Yes|
|Short-circuit protection of 24V and 10V reference voltages|Yes|
## **Input Fuses**
SHT fuses can be assembled into same-size DIN fuse base.
## **SPA9000/SPN9000/SPI9000**
|**Module**|||||||
|---|---|---|---|---|---|---|
|**Component**|**Frame**|**Bussman Fuse Type (aR)**|**Size**|**UN (V)**|**IN (A)**|**Qty.**|
|**Inverter Units**|||||||
|**SPI003A1-4**|FR4|170M1560|0|690|20|2|
|**SPI007A1-4**|FR4|170M1562|0|690|63|2|
|**SPI009A1-4**|FR4|170M1562|0|690|63|2|
|**SPI012A1-4**|FR6|170M1565|0|690|63|2|
|**SPI016A1-4**|FR6|170M1565|0|690|63|2|
|**SPI023A1-4**|FR6|170M1565|0|690|63|2|
|**SPI031A1-4**|FR6|170M1567|0|690|100|2|
|**SPI038A1-4**|FR6|170M1567|0|690|100|2|
|**SPI061A1-4**|FR7|170M1570|0|690|200|2|
|**SPI072A1-4**|FR7|170M1570|0|690|200|2|
|**SPI087A1-4**|FR7|170M1571|0|690|250|2|
|**SPI105A0-4**|FR8|170M3819|DIN1|690|400|2|
|**SPI140A0-4**|FR8|170M3819|DIN1|690|400|2|
|**SPI170A0-4**|FR8|170M3819|DIN1|690|400|2|
|**SPI205A0-4**|FI9|170M6812|DIN3|690|800|2|
|**SPI245A0-4**|FI9|170M6812|DIN3|690|800|2|
|**SPI300A0-4**|FI10|170M8547|3SHT|690|1250|2|
|**SPI385A0-4**|FI10|170M8547|3SHT|690|1250|2|
|**SPI460A0-4**|FI10|170M8547|3SHT|690|1250|2|
|**SPI520A0-4**|FI12|170M8547|3SHT|690|1250|2 x 2|
|**SPI590A0-4**|FI12|170M8547|3SHT|690|1250|2 x 2|
|**SPI650A0-4**|FI12|170M8547|3SHT|690|1250|2 x 2|
|**SPI730A0-4**|FI12|170M8547|3SHT|690|1250|2 x 2|
|**SPI820A0-4**|FI12|170M8547|3SHT|690|1250|2 x 2|
|**SPI920A0-4**|FI12|170M8547|3SHT|690|1250|2 x 2|
|**SPIH10A0-4**|FI13|170M8547|3SHT|690|1250|6|
|**SPIH11A0-4**|FI13|170M8547|3SHT|690|1250|6|
|**SPIH13A0-4**|FI13|170M8547|3SHT|690|1250|6|
|**SPIH16A0-4**|FI14|170M8547|3SHT|690|1250|2 x 6|
|**SPIH19A0-4**|FI14|170M8547|3SHT|690|1250|2 x 6|
|**SPIH23A0-4**|FI14|170M8547|3SHT|690|1250|2 x 6|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-289**
Adjustable Frequency Drives
## 2.10
## SPA9000/SPN9000/SPI9000 Common DC Bus Drives
SHT fuses can be assembled into same-size DIN fuse base.
## **SPA9000/SPN9000/SPI9000, continued**
**2**
|**Module**|||||||
|---|---|---|---|---|---|---|
|**Component**|**Frame**|**Bussman Fuse Type (aR)**|**Size**|**UN (V)**|**IN (A)**|**Qty.**|
|**Active Front Ends**|||||||
|**SPA205A0-4**<br>**SPA385A0-4**|FI9<br>FI10|170M6202<br>170M6277|3SHT<br>3SHT|1250<br>1250|500<br>1000|3<br>3|
|**SPAH10A0-4**|FI13|170M6277|3SHT|1250|1000|3 x 3|
|**Non-Regenerative**|**Front Ends**||||||
|**SPN468A0-4**|FI9|170M8547|3SHT|690|1250|3|
## **Wiring Diagrams**
**SPA9000—**
**==> picture [67 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
Active Front End<br>**----- End of picture text -----**<br>
## **SPN9000—NonRegenerative Front End**
**SPI9000—Inverter Unit (FR4–FR8)**
**SPI9000—Inverter Unit (FI9–FI14)**
**==> picture [501 x 220] intentionally omitted <==**
**----- Start of picture text -----**<br>
380 – 500 Vac 380 – 500 Vac 425 – 800 Vdc 425 – 800 Vdc<br>L1 L1 DC [+] DC [+]<br>L2 L2 DC [-] DC [-]<br>L3 L3<br>INU DC+ DC- INU DC+ DC-<br>AFE -F1 NFE -F1 -F1<br>-F1<br>-K4 -F4<br>-L1.1<br>-K5<br>-V4<br>-L1.2<br>-L1<br>-R4<br>-U1 -U1<br>PE U V W PE U V W<br>-F2 -F2<br>425 – 600 Vdc 425 – 800 Vdc M M<br>DC [+] DC [+]<br>DC [-] DC [-]<br>**----- End of picture text -----**<br>
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-290**
Adjustable Frequency Drives
2.10
SPA9000/SPN9000/SPI9000 Common DC Bus Drives
## **Dimensions**
Approximate Dimensions in Inches (mm) **SPA9000/SPN9000/SPI9000**
**2**
|||||**Weight**|
|---|---|---|---|---|
|**Frame**|**Height**|**Width**|**Depth**|**Lbs (kg)**|
|**Active Front Ends**|||||
|FI9|40.6 (1030)|9.4 (239)|14.6 (372)|148 (67)|
|FI10|40.6 (1032)|9.4 (239)|21.7 (552)|220 (100)|
|FI12|40.6 (1032)|2 x 9.4 (2 x 239)|21.7 (552)|441 (200)|
|FI13|40.6 (1032)|27.9 (708)|21.8 (553)|674 (306)|
|FI14|40.6 (1032)|2 x 27.9 (2 x 708)|21.8 (553)|1348 (612)|
|**Non-Regenerative Front**||**Ends**|||
|FI9|40.6 (1030)|9.4 (239)|14.6 (372)|148 (67)|
|**Inverter Units**|||||
|FR4|11.5 (292)|5.0 (128)|7.5 (190)|11 (5)|
|FR6|20.4 (519)|7.7 (195)|9.3 (237)|35 (16)|
|FR7|23.3 (591)|9.3 (237)|10.1 (257)|64 (29)|
|FR8|29.8 (758)|11.4 (289)|13.5 (344)|106 (48)|
|FI9|40.6 (1030)|9.4 (239)|14.6 (372)|148 (67)|
|FI10|40.6 (1032)|9.4 (239)|21.7 (552)|220 (100)|
|FI12|40.6 (1032)|2 x 9.4 (2 x 239)|21.7 (552)|441 (200)|
|FI13|40.6 (1032)|27.9 (708)|21.8 (553)|674 (306)|
|FI14|40.6 (1032)|2 x 27.9 (2 x 708)|21.8 (553)|1348 (612)|
**Volume 6—Solid-State Motor Control** CA08100007E—May 2014 www.eaton.com
**V6-T2-291**
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →