Image not available
Illustrative purposes only
DUALCON-6
Signal Converter, Current, RTD, Thermocouple, Current, Voltage, 2 Channels, ± 0.5%, 24 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: IMO PRECISION CONTROLS
- Product type: Signal Converters
- Signal Conditioner Input:Current, RTD, Thermocouple; Signal Conditioner Output:Current, Voltage; No. of Output Channels:2Channels; Accuracy %:-; Output Accuracy:± 0.5%; Supply Voltage:24V; No
- Accuracy %: -
- Product Range: -
- Supply Voltage: 24V
- Isolation Input: Isolated
- No. of Channels: 2 Channel
- Output Accuracy: ± 0.5%
- No. of Output Channels: 2Channels
- Signal Conditioner Input: Current, RTD, Thermocouple
- Signal Conditioner Output: Current, Voltage
- Signal Conditioner Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 354.7 € |
| Current stock | 10+ |
| Lead time | 30 days |
Isolating Signal Converter 2 outputs DUALCON The new DUALCON Isolating Signal Converter can accept a wide range of inputs including 4-20mA, thermocouple, RTD and voltage signals. The units produce two high level DC outputs of either voltage or current. ❚ Universal configurable input - user selectable ❚ 2 configurable Outputs - user selectable ❚ Full 3-Port Isolation ❚ Wide range AC or DC Supply ❚ Isolated Transmitter Supply ❚ Very High Accuracy, Low Cost ❚ Only 17.5mm Wide on DIN rail "y ## **Options and ordering codes** **==> picture [108 x 67] intentionally omitted <==** **----- Start of picture text -----**<br> DUALCON - 6<br>|<br>90-264VAC supply 3<br>18-32VAC and 16-36VDC 6<br>**----- End of picture text -----**<br> ## **Description** ## **Inputs** Standard ranges are shown below - contact Sales for others. Full 3 port isolation is standard as is an isolated transmitter supply which can be used to power any standard 2-wire 4-20mA transmitter. The input type and range can be user selected using simple DIL switches inside the unit. All RTD and thermocouple inputs can be fully linearised. Non-interactive zero and span controls make adjustment of the unit, quick and simple. Other features include optional inversion of the input signal, on either one or both of the outputs. The unit is supplied with two power supply options either wide ranging ac or dc. The ac version operates from any supply from 90 to 264VAC and the dc version operates from 18 - 32VAC and 16 - 36VDC. For specials such as custom linearisation etc please contact the sales office. ## **DC/AC Current and Voltage** 0-20mA, 4-20mA, 0-10mA into 15 Ω |0-1V, 0-10V, 1-5V into 1MΩ<br>Min and Max full scale ranges are:<br>DC Current|Min and Max full scale ranges are:<br>0 - 1mA|0 - 60mA| |---|---|---| |Bipolar DC Current|±5mA|±10mA| |DC Voltage|0 - 1V|0 - 300V*| |Bipolar DC Voltage<br>2 Wire Pot<br>3 Wire Pot|±5V<br>0 - 125Ω<br>0 - 1kΩ|±10V<br>0 - 1kΩ<br>0 - 100kΩ| Note: For input voltages greater than 60VDC an IIR-Divider unit must be specified. ## **Thermocouples** Types E,J,K,N,R,S.T.B linearised or non-linearised Ranges: Wide range of inputs. Cold junction compensation (can be turned off) Upscale or downscale t/c burnout options ## **Resistance Thermometers** 2,3 or 4 wire PT100 or PT1000, linearised or non-linearised. Ranges: Wide range of inputs. Upscale or downscale RTD burnout options. ## **Outputs** **DC Current and Voltage** 0-20mA, 4-20mA, 0-10mA into maximum 1k Ω 0-10V, 1-5V into a minimum 7k Ω Others available up to a maximum of ~~ee~~ Current: 0-20mA. Voltage: 10VDC www.imopc.com Dualcon/03/03 ## Isolating Signal Converter 2 outputs DUALCON continued ## **Specification** **==> picture [482 x 183] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Parameter|Min|Typ|Max|Comments| |Supply Voltage|16VDC/18VAC|24V|36VDC/32VAC|90 to 264 for ac input version| |Supply Current (mA)|95|120|For 24VDC (280mA for 75ms on startup)| |Input Impedance (Volt)|1M|Ω|Dependent on range (Typ=10V)| |Input Impedance (mA)|15|Ω|Dependent on range (Typ=20mA)| |Volt drop (mA input)|0.3|At 20mA input| |Output Linearity Error|±0.01%|±0.05%| |Temp Coefficient|±50ppm/°C| |Time Constant (10-90%)|25ms (fast)|60ms (normal)|Selectable fast/normal response| |Operating Ambient|0°C|55°C| |Relative Humidity|0%|90%| |Isolation Voltage see note 1|1kV| |Surge Voltage|2.5kV for 50µS|Transient of 10kV/µS| |Notes|_|Absolute maximum ratings indicate sustained limits beyond which damage to the device may occur| |Accuracy figures based on 24VDC supply, 4-20mA output with 250 load and 20°C ambient.| |Device is protected against reverse polarity connection.| **----- End of picture text -----**<br> 1/ DUALCON does not provide safety isolation when the input is connected to the mains. ## **Dimensions and connections** **==> picture [252 x 120] intentionally omitted <==** **----- Start of picture text -----**<br> 99 4 17.5<br>114.5<br>**----- End of picture text -----**<br> **==> picture [215 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Installation Data| |Mounting|DIN Rail TS35| |Orientation|Any| |Connections|Screw Clamp with pressure plate| |Conductor size|0.5-4.0mm| |Insulation stripping|12mm| |Weight|Approx. 115g| **----- End of picture text -----**<br> **==> picture [222 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Connection Details| |1. Power Input -ve| |2. Power Input +ve| |4. Process Input -ve|T/C -ve|RTD -ve| |5. Process Input +ve|T/C +ve|RTD +ve| |3. Trans supply +ve|RTD 4th Wire| |6.|T/C Shield|RTD 3rd Wire| |10. Output 2 -ve|7. Output 1 -ve| |12. Output 2 +ve|9. Output 1 +ve| **----- End of picture text -----**<br> www.imopc.com Dualcon/03/03
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →