DTM36CN150C8
AC/DC Power Supply, Medical, 1 Output, 36 W, 15 VDC, 2.4 A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC External Plug In Adaptor Power Supplies
- SVHC: No SVHC (15-Jan-2018)
- Plug Type: IEC 60320 C8
- Product Range: DTM36-C8 Series
- No. of Outputs: 1 Output
- Output Connector: Barrel Plug Center Positive 2.1mm x 5.5mm x 12mm
- Output Power Max: 36W
- Input Voltage VAC: 80V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.4A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: Medical
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 24.03 € |
| Current stock | 10+ |
| Lead time | 30 days |
DTM36-C8 Series https://product.tdk.com/en/power/dtm ## 25 to 36W Medical External Power Supplies www. emea.lambda.tdk.com/dtm The DTM36-C8 Class II 25 to 36W external power supplies are certifi ed to IEC/ES/EN60601-1 and EN60601-1-11, are compliant to EN60601-1-2 (Ed4) and designed to meet IEC60335-1 (Household Appliances). Requiring no earth ground, the DTM series is ideally suited for Medical, Clinical and Home Healthcare applications. Alternative connectors and cable assemblies are available on request. |**Features**<br>**Benefi ts**<br>• Medical Safety Certifi cations and Immunity<br>• Class II Input<br>• Meets DoE Level VI and EU Tier 2 Effi ciency, <75mW Off-load Power Consumption<br>• 4kV (2xMOPP) Input to Output Isolation<br>• Alternative Connectors and Cable Assemblies<br>• Suitable for Medical, Clinical and Home Healthcare Use<br>• No Earth Ground Connection Needed<br>• Meets US and EU Energy Saving Legislation<br>• Fully Isolated For Use With B and BF Rated Equipment<br>• Flexible System Integration|**Features**<br>**Benefi ts**<br>• Medical Safety Certifi cations and Immunity<br>• Class II Input<br>• Meets DoE Level VI and EU Tier 2 Effi ciency, <75mW Off-load Power Consumption<br>• 4kV (2xMOPP) Input to Output Isolation<br>• Alternative Connectors and Cable Assemblies<br>• Suitable for Medical, Clinical and Home Healthcare Use<br>• No Earth Ground Connection Needed<br>• Meets US and EU Energy Saving Legislation<br>• Fully Isolated For Use With B and BF Rated Equipment<br>• Flexible System Integration|| |---|---|---| |||| |**Model Selector**<br>Output<br>Maximum<br>Maximum<br>Model<br>Voltage<br>Current<br>Power<br>(V)<br>(A)<br>(W)<br>DTM36CN050-C8<br>5<br>5<br>25<br>DTM36CN090-C8<br>9<br>3.3<br>29.7<br>DTM36CN120-C8<br>12<br>2.5<br>30<br>DTM36CN135-C8<br>13.5<br>2.4<br>32.4<br>DTM36CN150-C8<br>15<br>2.4<br>36<br>DTM36CN180-C8<br>18<br>2<br>36<br>DTM36CN240-C8<br>24<br>1.5<br>36<br>DTM36CN360-C8<br>36<br>1<br>36<br>DTM36CN480-C8<br>48<br>0.75<br>36|Overvoltage<br>Maximum<br>Effi ciency (%)<br>Average<br>Protection (V)<br>Load<br>(230Vac input,<br>Effi ciency<br>(Typical)<br>Capacitance (uF)<br>75% Load)<br>(%) (1)<br>7.44<br>5,000<br>85<br>85.0<br>12.6<br>3,300<br>88<br>87.7<br>15.9<br>2,500<br>89<br>87.7<br>18.5<br>2,400<br>89<br>87.9<br>21.5<br>2,400<br>89<br>88.3<br>24.8<br>2,000<br>89<br>88.3<br>31.5<br>1,500<br>89<br>88.3<br>45.2<br>1,000<br>89<br>88.3<br>59.6<br>750<br>89<br>88.3|| |||| |**DTM36CN**<br>**120**<br>Output voltage 5, 9, 12, 13.5, 15, 18, 24, 36, 48<br>re|Connector/Cable Options*<br>(When applicable)<br>**C8**<br>**-**<br>**xxx**<br>IEC C8 input connector<br> ee|| * Options When no option code is stated: 5V output model has a straight 5.5 x 2.1 x 12mm (OD x ID x L) connector, positive center pin and a 16 AWG 1220mm long cable 9V, 12V and 13.5V output models have a straight 5.5 x 2.1 x 12mm (OD x ID x L) connector, positive center pin and an 18 AWG 1800mm long cable >15 models have a straight 5.5 x 2.1 x 12mm (OD x ID x L) connector, positive center pin and an 20 AWG 1800mm long cable DTM36-C8 Series 1 **==> picture [511 x 34] intentionally omitted <==** ## **Specifi cations** **==> picture [511 x 209] intentionally omitted <==** **----- Start of picture text -----**<br> Model DTM36-C8<br>Input<br> Input Voltage range (2) Vac 80 - 264<br> Input Frequency Hz 47 - 63<br> Input Current (110/230Vac) A < 0.9<br> Inrush Current at 240Vac (Cold Start) A < 100<br> Leakage Current uA < 80<br> Harmonic Compliance - Meets IEC61000-3-2<br> No Load Power Consumption mW < 75<br> Hold Up Time (typ) at 115Vac Input ms 10<br> Effi ciency - See model selector table<br> Average Effi ciency - See model selector table<br> Conducted & Radiated EMI - EN55011-B Conducted, EN55011-B Radiated, EN60601-1-2<br> Immunity - See immunity table<br> Insulation Class - Class II<br> Safety Agency Certifi cations - IEC/ES/EN60601-1, EN60601-1-11, CE Mark (LVD, EMC and RoHS). Designed to meet IEC60335-1<br>**----- End of picture text -----**<br> ## **Immunity** |**Immunity**|**Immunity**|**Immunity**|**Immunity**|**Immunity**| |---|---|---|---|---| |Test|Standard|Test Level|Criteria|Notes| |ESD|EN61000-4-2|4|A|| |Radiated Susceptibility|EN61000-4-3<br>EN60601-1-2 table 9|3<br>-|A<br>A|80-2700MHz<br>Pass| |Electrical Fast Transient Burst|EN61000-4-4|3|A|(AC Port,100kHz)| |Surge|EN61000-4-5|3|A|-| |Conducted Susceptibility|EN61000-4-6<br>EN60601-1-2 table 6|3<br>-|A<br>A|10V (61000-6-2)<br>6V (60601-1-2)| |Magnetic f elds|EN61000-4-8|N/A|N/A|-| |Voltage Dips and<br>Input Interruptions|EN61000-4-11 Class 2<br>Industrial, including<br>EN60601-1-2<br>(100Vac)|0% for 1/2 cycle<br>0% for 1 cycle<br>70% for 25/30 cycles<br>0% for 250/300 cycles|A<br>A<br>A<br>B|| DTM36-C8 Series 2 **==> picture [511 x 34] intentionally omitted <==** **==> picture [512 x 453] intentionally omitted <==** **----- Start of picture text -----**<br> Specifi cations<br>Model DTM36-C8<br>Output<br> Output Voltage Tolerance % ±2% at 60% load<br> Output Voltage Adjustment - None<br> Switching Frequency (Typical) kHz 65<br> Line Regulation % ±1% of rated output voltage from 100 to 240Vac<br> Load Regulation (3) % 5V: ±6%, 9V: ±4%, 12-48V: ±2% of rated output voltage<br> External Load Capacitance uF See model selector table<br> Ripple & Noise (4) mV 5V: 100, 9V & 12V: 120, 13.5V: 130, 15V: 150, 18V: 180, 24V: 240, 36V: 360, 48V: 480<br> Temperature Coeffi cient %/°C ±0.05<br> Minimum Load - No minimum load required<br> Overcurrent Protection - Hiccup mode with auto recovery<br> Overvoltage Protection V Diode clamp, auto recovery. See model selector table<br> Indicators - LED indicates DC output is on<br> Parallel Operation - Not possible<br>Environmental<br> Operating Temperature °C -30 to 60, derate linearly from 100% to 60% load from 40 to 60<br> Storage Temperature °C -30 to +85<br> Humidity (non condensing) %RH 5 - 93%RH<br> Cooling - Convection<br> Altitude m 5,000<br> Withstand Voltage (For 1 minute) Vac Input to Output 4,000 (2xMOPP)<br> Isolation Resistance MΩ >100 at 25°C<br> IP Rating - IP21<br> Vibration (Operating) - Meets MIL-STD-810F Table 516.5, Table 516.5-1, 10ms, each axis 3 times (± X, Y, Z axis)<br> Shock - Meets MIL-STD-810F Table 514.5C-VIII, 15~200Hz, X, Y, Z axis, 1hr each axis, total 3hrs<br>Other<br> Weight (Typ) g 150<br> Size (LxWxH) mm 100 x 45 x 22.5<br> Size (LxWxH) Inches 3.937 x 1.771 x 0.886<br> AC Input Connector - IEC 320-C8 (2 prong)<br> DC Output Connector - See model selector (options)<br> MTBF - MIL-HDBK-217F, GB, 25°C, 115Vac input hrs 1,000,000 max<br> Warranty yrs 3<br>**----- End of picture text -----**<br> ## Notes See website for detailed specifi cations, test methods and installation manual (1) Measured at 25%, 50%, 75% and 100% load conditions (2) Derate linearly from 100% to 75% load from 90Vac input to 80Vac input (3) Measured from 60 - 100% and 60 - 20% load (4) Ripple and noise is measured at 20MHz BW. Add 0.1uF ceramic capacitor and 10uF Electrolytic capacitor in parallel across the output DTM36-C8 Series 3 ## **Outline Drawing** (Straight connector with 20AWG 1,800mm cable shown) DTM36-C8 Series 4 For additional information, please visit https://product.tdk.com/en/power/ DTM36-C8_Datasheet_260660 August 5th, 2020 v1.5 DTM36-C8 Series 5
Updated at June 3, 2026
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →