- Manufacturer: EATON MOELLER
- Product type: Motor Starters
- SVHC: No SVHC (17-Dec-2015)
- No. of Poles: 4 Pole
- Power Rating: 30hp
- No. of Phases: Three Phase
- Product Range: DS7
- Current Rating: 100A
- IP / NEMA Rating: IP20
- Motor Starter Type: Soft Starter
- Supply Voltage Max: 480VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1067.49 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DATASHEET - DS7-340SX100N0-N** **Soft starter, 100 A, 200 - 480 V AC, Us= 24 V AC/DC, Frame size FS3** **Part no. DS7-340SX100N0-N Catalog No. 134920 Alternate Catalog DS7-340SX100N0-N No. EL-Nummer 0004134205 (Norway)** ## **Delivery program** |**No.**<br>**EL-Nummer**<br>**(Norway)y)) **<br>**0004134205**<br>**Deliveryy programrogramgramram**|||| |---|---|---|---| |Description|||With internal bypass contacts| |Function|||Soft starters for three-phase loads| |Mains supply voltage (50/60 Hz)|ULN|V AC|200 - 480| |Supply voltage|Us||24 V AC/DC| |Control voltage|UC||24 V AC<br>24 V DC| |**Assigned motor rating (Standard connection, In-Line)**|||| |at 400 V, 50 Hz|P|kW|55| |at 460 V, 60 Hz|P|HP|75| |**Rated operational current**|||| |AC-53|Ie|A|100| |Rated operational voltage|Ue||200 V<br>230 V<br>400 V<br>480 V| |Connection to SmartWire-DT|||no| |Frame size|||FS3| |Standards|||IEC/EN 60947-4-2<br>UL 508<br>CSA22.2-14| |---|---|---|---| |Approvals|||CE| |Approvals|||UL<br>CSA<br>C-Tick<br>UkrSEPRO| |Climatic proofing|||Damp heat, constant, to IEC 60068-2-3<br>Damp heat, cyclic, to IEC 60068-2-10| |Ambient temperature|||| |Operation|ϑ|°C|-5 - +40<br>up to 60 at 2% derating per Kelvin temperature rise| |Storage|ϑ|°C|-25 - +60| |Altitude||m|0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m| |Mounting position|||Vertical| |Degree of protection|||| |Degree of Protection|||IP20 (terminals IP00)| |Integrated|||Protection type IP40 can be achieved on all sides with covers from the NZM range.| |Protection against direct contact|||Finger- and back-of-hand proof| |Overvoltage category/pollution degree|||II/2| |Shock resistance|||8 g/11 ms| |Vibration resistance to EN 60721-3-2|||2M2| |Radio interference level (IEC/EN 55011)|||B| |Static heat dissipation, non-current-dependent|Pvs|W|25| |Weight||kg|1.8| 06/30/2020 Eaton 134920 ED2020 V69.0 EN 1 / 5 |Rated operational current|Ie|A|| |---|---|---|---| |AC-53|Ie|A|100| |Assigned motor rating (Standard connection, In-Line)|||| |at 230 V, 50 Hz|P|kW|30| |at 400 V, 50 Hz|P|kW|55| |at 200 V, 60 Hz|P|HP|30| |at 230 V, 60 Hz|P|HP|30| |at 460 V, 60 Hz|P|HP|75| |Overload cycle to IEC/EN 60947-4-2|||| |AC-53a|||100 A: AC-53a: 3 - 5: 75 - 10| |Internal bypass contacts|||✓| |Short-circuit rating|||| |Type “1” coordination|||NZMN1-M100| |Type „2“ coordination (additional with the fuses for coordination type „1“)|||3 x 170M4008| ||||| |Fuse base (number x part no.)|||3 x 170H3004| |**Terminal capacities**|||| |Cable lengths|||| |Solid||mm2|1 x (25 - 70)<br>2 x (6 - 25)| |Stranded||mm2|1 x (25 - 70)<br>2 x (6 - 25)| |Solid or stranded||AWG|1 x (12 - 2/0)| |Copper band||MM|2 x 9 x 0.8 9 x 9 x 0.8| |Tightening torque||Nm|6 (≤ 10 mm²); 9 (> 10 mm²)| |Screwdriver (PZ: Pozidriv)||mm|PZ2; 1 x 6 mm| |Control cables|||| |Solid||mm2|1 x (0.5 - 2.5)<br>2 x (0.5 - 1.0)| |Flexible with ferrule||mm2|1 x (0.5 - 1.5)<br>2 x (0.5 - 0.75)| |Stranded||mm2|1 x (0.5 - 1.5)<br>2 x (0.5 - 1.0)| |Solid or stranded||AWG|1 x (21 - 14)<br>2 x (21 - 18)| |Tightening torque||Nm|0.4| |Screwdriver||mm|0,6 x 3,5| |**Control circuit**|||| |Digital inputs|||| |Control voltage|||| |DC-operated||V DC|24 V DC +10 %/- 15 %| |AC operated||V AC|24 V AC +10 %/- 15 %| |Current consumption 24 V||mA|| |External 24 V||mA|1.6| |Pick-up voltage||x Us|| |DC-operated||V DC|17.3 - 27| |AC operated||V AC|17.3 - 27| |Drop-out voltage|x Us||| |DC operated||V DC|0 - 3| |AC operated||V AC|0 - 3| |Pick-up time|||| |DC operated||ms|250| |AC operated||ms|250| |Drop-out time|||| |DC operated||ms|350| |Regulator supply|||| |Voltage|Us|V|24 V AC/DC +10 %/- 15 %| |Current consumption|Ie|mA|50| 06/30/2020 Eaton 134920 ED2020 V69.0 EN 2 / 5 |Current consumption at peak performance (close bypass) at 24 V DC|IPeak|A/ms|0,6/50|0,6/50| |---|---|---|---|---| |Notes|||External supply voltage|| |Relay outputs||||| |Number|||2 (TOR, Ready)|| |Voltage range||V AC|250|| |AC-11 current range||A|1 A, AC-11|| |**Soft start function**||||| |Ramp times||||| |Acceleration||s|1 - 30|| |Deceleration||s|0 - 30|| |Start voltage (= turn-of voltage)||%|30 100|| |<br>Start pedestal||%|30 - 100|| |Fields of application||||| |Fields of application|||Soft starting of three-phase asynchronous motors|| |1-phase motors|||●|| |3-phase motors|||✓|| |**Functions**||||| |Fast switching (semiconductor contactor)|||- (minimum ramp time 1s)|| |Soft start function|||✓|| |Reversing starter|||External solution required|| |Suppression of closing transients|||✓|| |Suppression of DC components for motors|||✓|| |Potential isolation between power and control sections|||✓|| |**Notes**||||| |Rated impulse withstand voltage:<br>•<br>1.2 µs/50 µs (rise time/fall time of the pulse to IEC/EN 60947‐2 or ‐3)<br>•<br>Applies for control circuit/power section/enclosure||||| ## **Desig per IEC/EN 61439** |<br>Technical data for design verifcation|||| |---|---|---|---| |<br>Rated operational current for specifed heat dissipation|In|A|100| |Heat dissipation per pole, current-dependent|Pvid|W|0| |Equipment heat dissipation, current-dependent|Pvid|W|25| |Static heat dissipation, non-current-dependent|Pvs|W|25| |Heat dissipation capacity|Pdiss|W|0| |Operating ambient temperature min.||°C|-5| |Operating ambient temperature max.||°C|40| |IEC/EN 61439 design verifcation|||| |<br>10.2 Strength of materials and parts|||| |10.2.2 Corrosion resistance|||Meets the product standard's requirements.| |10.2.3.1 Verifcation of thermal stability of enclosures|||Meets the product standard's requirements.| |<br>10.2.3.2 Verifcation of resistance of insulating materials to normal heat|||Meets the product standard's requirements.| |<br>10.2.3.3 Verifcation of resistance of insulating materials to abnormal heat<br>and fre due to internal electric efects|||Meets the product standard's requirements.| |<br>10.2.4 Resistance to ultra-violet (UV) radiation|||Meets the product standard's requirements.| |10.2.5 Lifting|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.6 Mechanical impact|||Does not apply, since the entire switchgear needs to be evaluated.| |10.2.7 Inscriptions|||Meets the product standard's requirements.| |10.3 Degree of protection of ASSEMBLIES|||Does not apply, since the entire switchgear needs to be evaluated.| |10.4 Clearances and creepage distances|||Meets the product standard's requirements.| |10.5 Protection against electric shock|||Does not apply, since the entire switchgear needs to be evaluated.| |10.6 Incorporation of switching devices and components|||Does not apply, since the entire switchgear needs to be evaluated.| |10.7 Internal electrical circuits and connections|||Is the panel builder's responsibility.| |10.8 Connections for external conductors|||Is the panel builder's responsibility.| |10.9 Insulation properties|||| |10.9.2 Power-frequency electric strength|||Is the panel builder's responsibility.| 06/30/2020 Eaton 134920 ED2020 V69.0 EN 3 / 5 |10.9.3 Impulse withstand voltage|||Is the panel builder's responsibility.| |---|---|---|---| |10.9.4 Testing of enclosures made of insulating material|||Is the panel builder's responsibility.| |10.10 Temperature rise|||The panel builder is responsible for the temperature rise calculation. Eaton will<br>provide heat dissipation data for the devices.| |10.11 Short-circuit rating|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.12 Electromagnetic compatibility|||Is the panel builder's responsibility. The specifcations for the switchgear must be<br>observed.| |10.13 Mechanical function|||The device meets the requirements, provided the information in the instruction<br>leafet (IL) is observed.| ## **Technical data ETIM 7.0** Low-voltage industrial components (EG000017) / Soft starter (EC000640) |**Technical data ETIM 7.0**|**Technical data ETIM 7.0**|**Technical data ETIM 7.0**|**Technical data ETIM 7.0**| |---|---|---|---| |Low-voltage industrial components (EG000017) / Soft starter (EC000640)|||| |Electric engineering, automation, process control engineering / Low-voltage switch technology / Load breakout, motor breakout / Semiconductor motor controller or soft starter<br>(ecl@ss10.0.1-27-37-09-07 [ACO300011])|||| |Rated operation current Ie at 40 °C Tu||A|100| |Rated operating voltage Ue||V|230 - 460| |Rated power three-phase motor, inline, at 230 V||kW|30| |Rated power three-phase motor, inline, at 400 V||kW|55| |Rated power three-phase motor, inside delta, at 230 V||kW|0| |Rated power three-phase motor, inside delta, at 400 V||kW|0| |Function|||Single direction| |Internal bypass|||Yes| |With display|||No| |Torque control|||No| |Rated surrounding temperature without derating||°C|40| |Rated control supply voltage Us at AC 50HZ||V|24 - 24| |Rated control supply voltage Us at AC 60HZ||V|24 - 24| |Rated control supply voltage Us at DC||V|24 - 24| |Voltage type for actuating|||AC/DC| |Integrated motor overload protection|||No| |Release class|||Other| |Degree of protection (IP)|||IP20| |Degree of protection (NEMA)|||1| ## **Approvals** |**Approvals**|||| |---|---|---|---| |Product Standards|||IEC/EN 60947-4-2; GB 14048.6; UL 508; CSA-C22.2 No 0-M91; CSA-C22.2 No 14-05 CE<br>marking| |UL File No.|||E251034| |CSA File No.|||2511305| |CSA Class No.|||321106| |Specially designed for North America|||No| |Suitable for|||Branch circuits| |Current Limiting Circuit-Breaker|||No| |Max. Voltage Rating|||480 V| |Degree of Protection|||IP20; UL/CSA Type 1| 06/30/2020 Eaton 134920 ED2020 V69.0 EN 4 / 5 **Dimensions** ## **Additional product information (links)** ## **IL03902005Z Instructions for DS7 Soft Starter** IL03902005Z Instructions for DS7 Soft Starter ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL03902005Z2019_10.pdf **MN03901001Z Manual DS7 soft starters** MN03901001Z Handbuch DS7 Sanftstarter - Deutsch MN03901001Z Manual DS7 soft starters - English MN03901001Z Manuale Softstarter DS7 - italiano CA04020001Z_EN-INT Product range catalog: Efficient Engineering for starting and controlling motors. ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN03901001Z_DE.pdf ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN03901001Z_EN.pdf ftp://ftp.moeller.net/DOCUMENTATION/AWB_MANUALS/MN03901001Z_IT.pdf http://www.eaton.eu/ecm/groups/public/@pub/@europe/@electrical/documents/content/pct_1095238.pdf Eaton Industries GmbH http://www.eaton.eu © 06/2020 by Eaton Industries GmbH Eaton 134920 ED2020 V69.0 EN 06/30/2020 5 / 5
Updated at March 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →