Image not available
Illustrative purposes only
DRP012V100W1AA
POWER SUPPLY, AC-DC, 12V, 8.33A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS / POWER
- Product type: AC / DC DIN Rail Mount Power Supplies
- Product Range: DRP Series
- No. of Outputs: 1 Output
- Output Power Max: 60W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 8.33A
- Output Voltage - Output 1: 12V
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 58.71 € |
| Current stock | 50+ |
| Lead time | 7 days |
**TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## **Highlights & Features** - Universal AC input voltage - Power will not de-rate for the entire input voltage range - Power Boost of 150% for 3 seconds - Full corrosion resistant aluminium chassis - Hazardous Locations approval to ATEX and Class I, Div 2 - Overvoltage / Overcurrent / Over Temperature / Short Circuit Protections ## **Safety Standards** CB Certified for worldwide use **Model Number:** DRP012V100W1AA **Unit Weight:** 0.64 kg (1.41 lb) **Dimensions (L x W x D):** 121 x 50 x 118.7 mm (4.76 x 1.97 x 4.67 inch) ## **General Description** The DRP012V100W1AA is part of the CliQ DIN rail power supply series from one of the world’s leading power supply companies, Delta Electronics Group. The rugged metal case is made to withstand harsh industrial environments, which is both shock and vibration resistant according to IEC 60068-2 standard. The product operates within a wide temperature range from -20°C to +80°C. The DRP012V100W1AA features universal AC input voltage range from 85Vac to 264Vac and the power will not de-rate for the entire input voltage range. The single phase power supply unit includes overvoltage, overcurrent, over temperature and short circuit protections. The product features built-in Power Boost of 150% for 3 seconds. Such feature enables reserve power to be always available for reliable startup of loads with high inrush current, thus eliminating the need of a more expensive power supply unit at higher power rating. Another great feature is the conformal coating on the PCBA which allows DRP012V100W1AA to be certified to ATEX and Class I, Div 2 for use in hazardous locations. ## **Model Information** CliQ DIN Rail Power Supply |CliQ DIN Rail Power Supply|||| |---|---|---|---| |**ModelNumber**|**Input Voltage Range**|**Rated OutputVoltage**|**Rated Output Current**| |DRP012V100W1AA|85-264Vac(120-375Vdc)|12Vdc|8.33A| ## **Model Numbering** |**DR**|**P**|**012V**|**100W**|**1**|**A**|**A**| |---|---|---|---|---|---|---| |DIN Rail|Power Supply|Output Voltage|Output Power|Single Phase|CliQ Series|Metal Case| All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 1 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## **Specifications** ## Input Ratings / Characteristics |Input Ratings / Characteristics|| |---|---| |Nominal Input Voltage|100-240Vac| |Input Voltage Range|85-264Vac| |Nominal Input Frequency|50-60Hz| |Input Frequency Range|47-63Hz| |DC Input Voltage Range*|120-375Vdc| |Input Current|< 2.50A @ 115Vac, < 1.50A @ 230Vac| |Efficiencyat 100% Load|> 85.5% @ 115Vac, > 87.5% @ 230Vac| |Max Inrush Current|< 100A @ 115Vac, No Damage @ 230Vac| |Leakage Current|< 1mA @ 240Vac| *Safety approval according to IEC/EN/UL 60950-1. ## Output Ratings / Characteristics |Output Ratings / Characteristics|| |---|---| |Nominal Output Voltage|12Vdc| |Output Voltage Tolerance|± 2%(initial setpoint tolerance from factory)| |Output Voltage Adjustment Range|11-14Vdc| |Output Current|8.33A (continuously operating at 12V)<br>12.495A (Power Boost for 3 seconds at 12V, refer to the<br>details in the Functions section)| |Output Power|100W (continuously operating at 12V)<br>150W (Power Boost for 3 seconds at 12V, refer to the<br>details in the Functions section)| |Line Regulation|< 0.5% typ.(@ 85-264Vac input, 100% load)| |Load Regulation|< 1% typ. (@ 85-264Vac input, 0-100% load)| |PARD(20MHz)|< 100mVpp| |Rise Time|< 40ms @ nominal input(100% load)| |Start-upTime|< 600ms @ nominal input(100% load)| |Hold-up Time|> 22ms @ 115Vac,<br>> 110ms @ 230Vac (100% load)| |Dynamic Response (Overshoot & Undershoot O/P Voltage)|± 5% @ 0-100% load| |Start-upwith Capacitive Loads|10,000µF Max| All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 2 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## Mechanical |Mechanical|Mechanical|| |---|---|---| |Case Cover / Chassis||Aluminium| |Dimensions (L x W x D)||121 x 50 x 118.7 mm(4.76 x 1.97 x 4.67 inch)| |Unit Weight||0.64 kg (1.41 lb)| |Indicator||Green LED(DC OK)| |CoolingSystem||Convection| |Terminal|Input|3 Pins(Rated 300V/20A)| ||Output|2 Pins (Rated 300V/20A)| |Wire|Input / Output|AWG 18-14| |MountingRail||Standard TS35 DIN Rail in accordance with EN 60715| |Noise(1 Meter frompower supply)||Sound Pressure Level(SPL)< 40dBA| ## Environment |Environment||| |---|---|---| |Surrounding Air Temperature|Operating|-20°C to +80°C| ||Storage|-25°C to +85°C| |Power De-rating|Vertical Mounting|> 50°C de-rate power by 2.5% / °C| ||Horizontal Mounting|> 50°C de-rate power by 2.5% / °C,<br>> 70°C de-rate power by 4% / °C| |OperatingHumidity||5 to 95% RH(Non-Condensing)| |OperatingAltitude||0 to 2,000 Meters(6,560 ft) (@ 50°C)| |Shock Test (Non-Operating)||IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,<br>1 time per direction, 6 times in total| |Vibration (Non-Operating)||IEC 60068-2-6, 10Hz to 500Hz @ 50m/S² (5G peak);<br>90 min per axis for all X, Y, Z direction| |Pollution Degree||2| ## Protections |Protections|| |---|---| |Overvoltage|16V, +10% / -5%, SELV Output, Hiccup Mode,<br>Non-Latching (Auto-Recovery)| |Overload / Overcurrent|> 150% of rated load current, Hiccup Mode,<br>Non-Latching (Auto-Recovery)| |Over Temperature|< 80°C Surrounding Air Temperature @ 100% load,<br>Non-Latching (Auto-Recovery)| |Short Circuit|Hiccup Mode, Non-Latching<br>(Auto-Recovery when the fault is removed)| |Protection Against Shock|Class I with PE* connection| *PE: Primary Earth ## Reliability Data |Reliability Data|| |---|---| |MTBF|> 500,000 hrs. as per Telcordia SR-332<br>I/P: 115Vac, O/P: 100% load, Ta: 25°C| |Expected CapLife Time|10years(115Vac & 230Vac, 50% load @ 40°C)| All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 3 **TECHNICAL DATASHEET** **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## Safety Standards / Directives |Safety Standards / Directives|Safety Standards / Directives|| |---|---|---| |Electrical Equipment in Power Installations||EN 50178 / IEC 62103| |Electrical Safety||TUV to EN 60950-1, UL/cUL recognized to UL 60950-1<br>and CSA C22.2 No. 60950-1 (File No. E191395),<br>CB scheme to IEC 60950-1| |Industrial Control Equipment||UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01<br>(File No. E315355), CSA to CSA C22.2 No. 107.1-01<br>(File No. 181564)| |Hazardous Location / ATEX||cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA<br>12.12.01:2011<br>Class I, Division 2, Group A, B, C, D T4, Ta= -20°C to<br>+80°C (> +50°C derating)<br>EN 60079-0:2012, EN 60079-15:2010 ( II 3G Ex nA<br>IIC T4 Gc, Ta= -20°C to +80°C (> +50°C derating))<br>&| |II 3G ATEX 94/9/EC<br>€)||Certificate No. EPS 12 ATEX 1 491 X| |CE||In conformance with EMC Directive 2014/30/EU and<br>Low Voltage Directive 2014/35/EU<br>In conformance with Equipment for explosive<br>atmospheres (ATEX) directive 2014/34/EU| |Material and Parts||RoHS Directive 2011/65/EU Compliant| |Galvanic Isolation|Input to Output|4.0KVac| ||Input to Ground|1.5KVac| ||Output to Ground|1.5KVac| All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 4 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## EMC |EMC|| |---|---| |EMC / Emissions|CISPR 32, EN 55032, CISPR 11, EN 55011,<br>FCC Title 47: Class B| |Immunityto|EN 55024, EN 61000-6-1, EN 61000-6-2| |Electrostatic Discharge<br>IEC 61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge: 8kV| |Radiated Field<br>IEC 61000-4-3|Level 3 Criteria A1)<br>80MHz-1GHz, 10V/M, 80% modulation (1kHz)<br>1.4GHz-2GHz, 3V/M, 80% modulation (1kHz)<br>2GHz-2.7GHz, 1V/M, 80% modulation (1kHz)| |Electrical Fast Transient / Burst<br>IEC 61000-4-4|Level 3 Criteria A1)<br>2kV| |Surge<br>IEC 61000-4-5|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV| |Conducted<br>IEC 61000-4-6|Level 3 Criteria A1)<br>150kHz-80MHz, 10Vrms| |Power Frequency Magnetic Fields<br>IEC 61000-4-8|Criteria A1)<br>30A/Meter| |Voltage Dips<br>IEC 61000-4-11|100% dip; 1 cycle(20ms); Self Recoverable| |Low Energy Pulse Test (Ring Wave)<br>IEC 61000-4-12|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1Kv| |Harmonic Current Emission|IEC/EN 61000-3-2, Class A| |Voltage Fluctuation and Flicker|IEC/EN 61000-3-3| 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 5 ## **TECHNICAL DATASHEET CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## **Block Diagram** ## **Device Description** - 1) Input terminal block connector - 2) Output terminal block connector - 3) DC Voltage adjustment potentiometer 4) DC OK control LED (Green) 5) Universal mounting rail system All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 6 ## **TECHNICAL DATASHEET CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## **Dimensions** **L x W x D:** 121 x 32 x 120 mm (4.76 x 1.97 x 4.67 inch) ## **Engineering Data** Output Load De-rating VS Surrounding Air ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature > 50°C, the device may run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm (for Vertical Mounting) or 50mm (for Horizontal Mounting) with adjacent units while the device is in operation. **Fig. 1 De-rating for Vertical Mounting Orientation** > 50°C de-rate power by 2.5% / °C **De-rating for Horizontal Mounting Orientation** > 50°C de-rate power by 2.5% / °C, 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. If the device has to be mounted in any other orientation, please do not hesitate to contact **info@deltapsu.com** for more details. - 70°C de-rate power by 4% / °C All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 7 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## Output Load De-rating VS. Input Voltage - No output power de-rating across the entire input voltage range - ■L Frame / Enclosed ## **Assembly & Installation** The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN 60715. The device should be installed with input terminal block at the bottom. Each device is delivered ready to install. ## Mounting ## Dismounting ## **Fig. 2.1 Mounting** Snap on the DIN rail as shown in Fig. 2.1: 1. Tilt the unit upwards and insert it onto the DIN rail. 2. Push downwards until stopped. 3. Press against the bottom front side for locking. \ CA @ \ **Fig. 2.2 Dismounting** To uninstall, pull or slide down the latch with screw driver as shown in Fig. 2.2. Then slide the power supply unit (PSU) in the opposite direction, release the latch and pull out the power supply unit (PSU) from the rail. 4. Shake the unit slightly to ensure that it is secured. In accordance to EN 60950 / UL 50950, flexible cables require ferrules. Use appropriate copper cables designed to sustain operating temperature of at least 75°C or more to fulfill UL requirements. For stranded wires it is recommended to use suitable lug to crimp wires. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 8 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA Safety Instructions **Vertical Mounting** ## **Horizontal Mounting** - ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not turned OFF, there is risk of explosion / severe damage. - **To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral distance of 20mm (for Vertical Mounting) or 50mm (for Horizontal Mounting) to other units.** - Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. Risk of burns! - Only plug in and unplug connectors when power is turned off! - DO NOT insert any objects into the unit. - Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during this time. - The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants. - CAUTION: “For use in a controlled environment”. - The power supplies unit must be installed in an IP54 enclosure or cabinet in the final installation. The enclosure or cabinet must comply with EN 60079-0 or EN 60079-15. - Warning: Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2. - Warning: Explosion Hazard - Do not disconnect equipment or adjust potentiometer unless the power has been switched off or the area is known to be non-hazardous. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 9 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## **Functions** **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its set value. ## Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 90% of its set value, after the input voltage is removed. ## Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. ## Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 10 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## Power Boost Power Boost is the reserve power available constantly that allows reliable startup to support sudden and short spike of loads with high inrush current typically during turn on to remove the need of more expensive higher rated power supply unit. After the output has reached its steady state set value, the power supply can support surge loads with a higher short-term power demand up to 150% of maximum rated load (IO Max), for a maximum duration of 3 seconds. The Power Boost is also available to repeatedly basis with according to the condition of an average (R.M.S) output power shall not exceed continuous operating condition or refer to duty cycle calculation below. 𝐷𝑢𝑡𝑦 𝑐𝑦𝑐𝑙𝑒 (%) = 𝑇𝑃 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒 𝐴𝑣𝑒𝑟𝑎𝑔𝑒 𝑂𝑢𝑡𝑝𝑢𝑡 𝑃𝑜𝑤𝑒𝑟 (𝑃𝐴𝑣𝑔) =[(𝑃𝑜𝑤𝑒𝑟 𝐵𝑜𝑜𝑠𝑡 × 𝑇][𝑃][) + (𝑁𝑜𝑛-𝑃𝑒𝑎𝑘 𝑃𝑜𝑤𝑒𝑟× 𝑇][𝑁][)] 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒 ## OR 𝑁𝑜𝑛-𝑃𝑒𝑎𝑘 𝑃𝑜𝑤𝑒𝑟=[(][𝑃][𝐴𝑣][𝑔][× 𝑇𝑜𝑡𝑎𝑙 𝑇𝑖𝑚𝑒][)][ −(𝑃𝑜𝑤𝑒𝑟 𝐵𝑜𝑜𝑠𝑡 × 𝑇][𝑃][)] 𝑇𝑁 **An example of Power Boost and Average Output Power** **Peak Power Power Boost Non-Peak Non-Peak Power Total Time Power Boost Duty Cycle (WP) Duration (TP) Power (WN) Duration (TN) (T)** 150% 150 3 sec 10% 94W 27 sec 30 sec ~~||~~ 150% 150 3 sec 35% 73W 5.5 sec 8.5 sec ~~|~~ | | | | | | | 120% 120 6 sec 20% 95W 24 sec 30 sec ~~||~~ 120% 120 6 sec 35% 89W 11 sec 17 sec ~~aae~~ It is not recommended to prolong the duration of Power Boost to be longer than the specified duty cycle calculation, this may cause damage to the PSU. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 11 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## Overload & Overcurrent Protections The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 150% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. ## Overvoltage Protection The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. The power supply doesn’t shut down but goes in 2[nd] level regulation at 1516Vdc and continue to deliver the power. According to high output voltage which will be operating > 100% of rated load (16V × rated output current), if this condition persists, the power supply will sense OTP (Over Temperature Protection) and will go under hiccup mode. The power will return to normal operation once the fault condition is removed. It is not recommended to prolong the duration of IO when it is <150% but >100%, since it may cause damage to the PSU. ## Over Temperature Protection ## Short Circuit Protection The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. As mentioned above, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 12 **TECHNICAL DATASHEET** ## **CliQ DIN Rail Power Supply** 12V 100W 1 Phase / DRP012V100W1AA ## **Others** ## Delta RoHS Compliant ## **Restriction of the usage of hazardous substances** The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. ## Conformal Coating ## **The Protective Coating Technology** Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. The conformal coating dipping can be applied to PCBAs or circuit board. The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem especially in highly conversing atmosphere. ## PFC – Norm EN 61000-3-2 ## **Line Current Harmonic content** Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2018, Rev. 06)** 13
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →