- Manufacturer: TDK-LAMBDA
- Product type: AC / DC DIN Rail Mount Power Supplies
- Product Range: DRL10-100 Series
- No. of Outputs: 1 Output
- Output Power Max: 54W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 4.5A
- Output Voltage - Output 1: 12V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 38.92 € |
| Current stock | 10+ |
| Lead time | 7 days |
**DRL10-100 Series** **www.** emea.tdk-lambda.com/drl ## **10-100W Low Profile DIN Rail Mount Power Supplies** |**Features**|**Benefits**| |---|---| |• High Efficiency, up to 90% @ 230VAC|• Energy Saving - Improved Thermal Performance| |• UL1310 Class 2 Compliant|• Reduced Installation Costs (NEC Class 2)| |• Low No Load Consumption|• ErP Compliant| |• Long E-Cap-Life (>8 years @ 40°C, 75% Load, 230VAC)|• High In-Service Lifetime| |• Class II, Wide Range Input (85-264VAC)|• Global Application, No Earth Required| |**Specification**||||| |---|---|---|---|---| |**Model**||**DRL10**|**DRL30**<br>**DRL60**|**DRL100**| |Input Voltage Range|V||85 - 264VAC (Withstands 300VAC for 5 seconds)|| |Input Frequency|Hz||47 - 63Hz|| |Inrush Current at 230VAC(typ) (Cold Start)|A|40|50<br>60|60| |Power Factor (115/230VAC)|||Meets IEC61000-3-2 Class A|| |Input Current (110/230VAC)|A|0.56 / 0.42<br>0.18 / 0.12|0.58 / 0.45<br>0.5 / 0.43<br>0.6 / 0.4<br>1.2 / 0.8|0.5 / 0.47<br>2.0 / 1.1| |Line & Load Regulation|-||See model selector|| |Ripple & Noise|-||See model selector|| |Overcurrent Protection|-||>105% Hiccup with auto recovery|| |Overvoltage Protection|-||See model selector. Cycle AC input voltage to reset|| |Hold Up Time (typ) at 115VAC Input<br>Efficiency|ms<br>-|20|20<br>20<br>See model selector|15| |No Load Power Draw|W|<0.3|<0.3<br><0.5|<0.5| |LED Indicator|-||Green LED indicates DC is OK|| |||DRL10, 30, 60: -20° to +71°, derate linearly from 100% to 60% load from 55° to 71°|DRL10, 30, 60: -20° to +71°, derate linearly from 100% to 60% load from 55° to 71°|| |Operating Temperature (-25°C start-up)|°C|DRL100: -20° to +71°, derate linearly from 100% to 60% load from 51° to 71°|DRL100: -20° to +71°, derate linearly from 100% to 60% load from 51° to 71°|| |||DRL100 (<115VAC): -20° to +71°, derate linearly from 100% to 40% load from 40° to 71°||| |Storage Temperature|°C||40° to +85°|| |Operating Humidity (non condensing)|%RH||5 - 95|| |Parallel Operation|-||Not available|| |Series Opereration|-||Possible|| |Cooling|-||Convection|| |Operating Altitude|m||3,000|| |Withstand Voltage (For 1 minute)|VAC||Input to Output 3kVAC|| |Isolation Resistance|MΩ||>100MΩ at 25°C, 70%RH & 500VDC|| |Vibration (Operating)|-||IEC 60068-2-6, Sine Wave, 10-500Hz, 19.6m/s2(2G peak)<br>10 min per cycle, 60 min for all X,Y,Z directions|| |Shock|-|IEC 60068-2-27, Half Sine Wave, 39.2m/s2(4G ) for a duration of 22ms<br>3 shocks for each 3 directions, 9 times in total||| |Safety Agency Certifications|-|UL508 Listed, UL60950-1, UL1310 Class 2 (LPS), NEC Class 2 (except DRL60-12 & DRL100-24),<br>CSA22.2 No.60950-1, EN60950-1, CE Mark||| |Conducted & Radiated EMI|-||EN55022-B Conducted, EN55022-A Radiated|| |Immunity|-|EN61000-4-2 (lvl 3) , -3 (lvl 3), -4 (lvl 4), -5 (lvl 3), -6 (lvl 3), -8 (lvl 4), -11 (class 3)||| |Line Dip (200-240VAC)|-||SEMI F47 Compliant|| |Weight (Typ)|g|65|120<br>200|280| |Size (WxHxD)|mm|18 x 91 x 55.6|18 x 91 x 55.6<br>36 x 91 x 55.6<br>54 x 91 x 55.6|72 x 91 x 55.6| |Case Material|-||Flame Retardant Polycarbonate (UL94 V-0)|| |Warranty|yrs||3|| DRL10-100 Series 1 **==> picture [517 x 34] intentionally omitted <==** |**Model Selector**|||||||||| |---|---|---|---|---|---|---|---|---|---| |**Model**|**Output**<br>**Voltage**<br>**(V)**|**Adjust**<br>**Range**<br>**(V)**|**Max**<br>**Current**<br>**(A)**|**Max**<br>**Power**<br>**(W)**|**Load**<br>**Reg**<br>**(mV)**|**Line**<br>**Reg**<br>**(mV)**|**Ripple**<br>**& Noise**<br>**(mV)**|**Overvoltage Protection**<br>**Trigger Range**<br>**(V)**|**Effciency (%)**<br>**(115/230VAC)**| |**DRL10-12-1**|12|-|0.84|10.08|120|120|120|13.8 - 16.2|85 / 85| |**DRL30-12-1**|12|12 - 15|2.1|25.2|120|120|120|16 - 19|87 / 88| |**DRL60-12-1**|12|12 - 15|4.A|54|120|120|120|16 - 19|87 / 87| |**DRL10-24-1**|24|-|0.42|10|240|240|240|29 - 35|87 / 87| |**DRL30-24-1**|24|24 - 28|1.25|30|240|240|240|29 - 35|88 / 90| |**DRL60-24-1**|24|24 - 28|2.5|60|240|240|240|29 - 35|89 / 90| |**DRL100-24-1**|24|24 - 28|4.2|100.8|240|240|240|29 - 35|88 / 90| ## **Outline Drawing DRL10-1** **==> picture [511 x 384] intentionally omitted <==** **----- Start of picture text -----**<br> Notes:<br>A: Model, name, maximum output power, nominal output voltage,<br>maximum output current are shown here in accordance with the specifications<br>B: Country of manufacture will be shown here<br>C: Recommended screw torque (M2.5 - M2.6 s cr ew) : 0.56N• m ( 5.0 lb•inch)<br>D: Recommended wire: AWG12-24, wire strip lengt h: 4-5mm, 5mm max<br>**----- End of picture text -----**<br> DRL10-100 Series 2 **==> picture [516 x 34] intentionally omitted <==** ## **Outline Drawing DRL30-1** **==> picture [35 x 80] intentionally omitted <==** **==> picture [42 x 49] intentionally omitted <==** ## **Notes:** - A: Model, name, maximum output power, nominal output voltage, maximum output current are shown here in accordance with the specifications - B: Country of manufacture will be shown here C: Recommended screw torque (M2.5 - M2.6 screw): 0.56N•m (5.0 lb•inch) D: Recommended wire: AWG12-24, wire strip length: 4-5mm, 5mm max ## **Outline Drawing DRL60-1** **==> picture [35 x 66] intentionally omitted <==** **==> picture [42 x 50] intentionally omitted <==** ## **Notes:** - A: Model, name, maximum output power, nominal output voltage, maximum output current are shown here in accordance with the specifications - B: Country of manufacture will be shown here C: Recommended screw torque (M2.5 - M2.6 screw): 0.56N•m (5.0 lb•inch) D: Recommended wire: AWG12-24, ~~w~~ ir ~~e s~~ trip len ~~gth~~ : 4-5mm, 5mm max DRL10-100 Series 3 **==> picture [517 x 34] intentionally omitted <==** ## **Outline Drawing DRL100-1** **==> picture [511 x 322] intentionally omitted <==** **----- Start of picture text -----**<br> Notes:<br>A: Model, name, maximum output power, nominal output voltage,<br>maximum output current are shown here in accordance with the specifications<br>B: Country of manufacture will be shown here<br>C: Recommended screw torque (M2 . 5 - M2.6 screw): 0.56N•m (5.0 lb•inch)<br>D: Recommended wir e: A WG 12-24, wir e strip length: 4-5mm, 5mm max<br>**----- End of picture text -----**<br> DRL10-100 Series 4 ## **TDK-Lambda France SAS** 3 Avenue du Canada Parc Technopolis Bâtiment Sigma 91940 les Ulis France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com ## **Italy Sales Office** Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com ## **TDK-Lambda UK Ltd.** Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com ## **TDK-Lambda Ltd.** Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 info@tdk-lambda.co.il www.tdk-lambda.co.il ## **Netherlands** info@nl.tdk-lambda.com www.nl.tdk-lambda.com ## **TDK-Lambda Germany GmbH** Karl-Bold-Strasse 40 77855 Achern Germany ## **C.I.S.** **Commercial Support:** Tel: +7 (495) 665 2627 **Technical Support:** Tel: +7 (812) 658 0463 info@tdk-lambda.ru www.tdk-lambda.ru Tel: +49 7841 666 0 Fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com ## **Local Distribution** Ce ## **Austria Sales Office** Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 info@at.tdk-lambda.com www.de.tdk-lambda.com ## **Switzerland Sales Office** Bahnhofstrasse 50 8305 Dietlikon Switzerland Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 info@ch.tdk-lambda.com www.de.tdk-lambda.com ## **Nordic Sales Office** Haderslevvej 36B DK-6000 Kolding Denmark Tel: +45 2911 9556 info@dk.tdk-lambda.com **www.emea.tdk-lambda.com** DRL10-100 Oct16 v4 DRL10-100 Series 5
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →