Image not available
Illustrative purposes only
DRC-40B
AC/DC DIN Rail Power Supply (PSU), ITE, 2 Output, 40.02 W, 27.6 V, 950 mA, 27.6 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (25-Jun-2025)
- Product Range: DRC-40 Series
- No. of Outputs: 2 Output
- Output Power Max: 40.02W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 950mA
- Output Current - Output 2: 500mA
- Output Current - Output 3: -
- Output Voltage - Output 1: 27.6V
- Output Voltage - Output 2: 27.6V
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 21.42 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DRC - 40 series** ## 40W Single Output with Battery Charger (UPS Function) **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [362 x 324] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>Ls LPS c UL62368-1 W us BS EN/EN62368-1 4) www.ID 2000000000tuv.com CB IEC62368-1 TPTC004 FAL CE eSZk<br>■ Applications<br>* Security system<br>/ Over voltage * Emergency lighting system<br>reverse polarity protection * Alarm system<br>* DC UPS system<br>or 15 • Central monitoring system<br>low * Access systems<br>via relay)<br>■ GTIN CODE<br>MW Search: https://www.meanwell.com/serviceGTIN.aspx<br>rail type security power supply series. In addition to the primary output, there<br>rated current, enabling the backup power supply application the security<br>accepts the universal input between 90VAC and 264VAC, and supplies<br>respectively. With the efficiency up to 87%, it can operate with air<br>℃ ℃<br>**----- End of picture text -----**<br> **==> picture [13 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:DRC-40-SPEC 2024-01-26_ **DRC - 40 series** 40W Single Output with Battery Charger (UPS Function) ## **SPECIFICATION** ||**MODEL**<br>**DC VOLTAGE**<br>**OUTPUT NUMBER**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.4**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**BATTERY CUT OFF**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>400ms, 50ms/230VAC 800ms, 50ms/115VAC at full load<br>50ms/230VAC 10ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]<br>47 ~ 63Hz<br>86%<br>CH1:28.98 ~ 37.26V<br>20<br>1V<br>±<br>87%<br>0.8A/115VAC 0.6A/230VAC<br>COLD START 30A/115VAC 60A/230VAC<br>105 ~ 150% rated output power<br>CH1:14.49 ~ 18.63V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>UL62368-1, TUV BS EN/EN62368-1,<br>, AS/NZS 60950.1 approved<br>EAC TP TC 004<br>Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61204-3, light industry level,<br>EAC TP TC 020<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>10<br>0.5V<br>±<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 55<br>) on CH1 output<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>40*90*100mm (W*H*D)<br>0.3Kg; 42pcs/13.6Kg/0.82CUFT<br>**DRC-40B**<br>27.6V<br>13.8V<br>27.6V<br>CH1<br>CH2<br>CH2<br>0.95A<br>1A<br>0.5A<br>0 ~ 1.45A<br>--------<br>--------<br>40.02W<br>200mVp-p<br>--------<br>--------<br>--------<br>--------<br>--------<br>--------<br>--------<br>--------<br>CH1:24 ~ 30V<br>±1.0%<br>±0.5%<br>±0.5%<br>**DRC-40A**<br>13.8V<br>CH1<br>1.9A<br>0 ~ 2.9A<br>40.02W<br>120mVp-p<br>CH1:12 ~ 15V<br>±1.0%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power<br>supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded<br>permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher<br>℃<br>℃<br>than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>※<br>:<br>**FUNCTION**<br>**BATTERY LOW**<br>**AC OK**<br>Battery low voltage : < 22V<br>Open collector output, CONTACT : AC OK ; CUT OFF : AC Fail ; max. rating : 50V/30mA<br>Open collector output, CUT OFF : Battery ; CONTACT : Battery Low ; max. rating : 50V/30mA<br>Battery low voltage : < 11V<br>2496.2K hrs min.<br>Telcordia SR-332 (Bellcore) ; 536.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃|**MODEL**<br>**DC VOLTAGE**<br>**OUTPUT NUMBER**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.4**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**SAFETY STANDARDS**<br>**WORKING TEMP.**<br>**BATTERY CUT OFF**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>400ms, 50ms/230VAC 800ms, 50ms/115VAC at full load<br>50ms/230VAC 10ms/115VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]<br>47 ~ 63Hz<br>86%<br>CH1:28.98 ~ 37.26V<br>20<br>1V<br>±<br>87%<br>0.8A/115VAC 0.6A/230VAC<br>COLD START 30A/115VAC 60A/230VAC<br>105 ~ 150% rated output power<br>CH1:14.49 ~ 18.63V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>UL62368-1, TUV BS EN/EN62368-1,<br>, AS/NZS 60950.1 approved<br>EAC TP TC 004<br>Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020<br>Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61204-3, light industry level,<br>EAC TP TC 020<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>10<br>0.5V<br>±<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 55<br>) on CH1 output<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>40*90*100mm (W*H*D)<br>0.3Kg; 42pcs/13.6Kg/0.82CUFT<br>**DRC-40B**<br>27.6V<br>13.8V<br>27.6V<br>CH1<br>CH2<br>CH2<br>0.95A<br>1A<br>0.5A<br>0 ~ 1.45A<br>--------<br>--------<br>40.02W<br>200mVp-p<br>--------<br>--------<br>--------<br>--------<br>--------<br>--------<br>--------<br>--------<br>CH1:24 ~ 30V<br>±1.0%<br>±0.5%<br>±0.5%<br>**DRC-40A**<br>13.8V<br>CH1<br>1.9A<br>0 ~ 2.9A<br>40.02W<br>120mVp-p<br>CH1:12 ~ 15V<br>±1.0%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**SAFETY &**<br>**EMC**<br>**(Note 5)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power<br>supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded<br>permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher<br>℃<br>℃<br>than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>※<br>:<br>**FUNCTION**<br>**BATTERY LOW**<br>**AC OK**<br>Battery low voltage : < 22V<br>Open collector output, CONTACT : AC OK ; CUT OFF : AC Fail ; max. rating : 50V/30mA<br>Open collector output, CUT OFF : Battery ; CONTACT : Battery Low ; max. rating : 50V/30mA<br>Battery low voltage : < 11V<br>2496.2K hrs min.<br>Telcordia SR-332 (Bellcore) ; 536.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃|**DRC-40A**|**DRC-40A**|**DRC-40B**|**DRC-40B**| |---|---|---|---|---|---|---| |||**OUTPUT NUMBER**|CH1|CH2|CH1|CH2| |||**DC VOLTAGE**|13.8V|13.8V|27.6V|27.6V| |||**RATED CURRENT**|1.9A|1A|0.95A|0.5A| |||**CURRENT RANGE**|0 ~ 2.9A|--------|0 ~ 1.45A|--------| |||**RATED POWER**|40.02W||40.02W|| |||**RIPPLE & NOISE (max.) Note.2**|120mVp-p|--------|200mVp-p|--------| |||**VOLTAGE ADJ. RANGE**|CH1:12 ~ 15V||CH1:24 ~ 30V|| |||**VOLTAGE TOLERANCE Note.3**|±1.0%|--------|±1.0%|--------| |||**LINE REGULATION**|±0.5%|--------|±0.5%|--------| |||**LOAD REGULATION**|±0.5%|--------|±0.5%|--------| |||**SETUP, RISE TIME**<br>**Note.4**|400ms, 50ms/230VAC 800ms, 50ms/115VAC at full load|||| |||**HOLD UP TIME (Typ.)**|50ms/230VAC 10ms/115VAC at full load|||| |||**VOLTAGE RANGE**|90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]|||| |||**FREQUENCY RANGE**|47 ~ 63Hz|||| |||**EFFICIENCY (Typ.)**|86%||87%|| |||**AC CURRENT (Typ.)**|0.8A/115VAC 0.6A/230VAC|||| |||**INRUSH CURRENT (Typ.)**|COLD START 30A/115VAC 60A/230VAC|||| |||**OVERLOAD**|105 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||| |||**OVER VOLTAGE**|CH1:28.98 ~ 37.26V<br>CH1:14.49 ~ 18.63V<br>Protection type : Shut down o/p voltage, re-power on to recover|||| |||**BATTERY CUT OFF**|10<br>0.5V<br>±||20<br>1V<br>±|| |||**AC OK**|Open collector output, CONTACT : AC OK ; CUT OFF : AC Fail ; max. rating : 50V/30mA|||| |||**BATTERY LOW**|Battery low voltage : < 22V<br>Open collector output, CUT OFF : Battery ; CONTACT : Battery Low ; max. rating : 50V/30mA<br>Battery low voltage : < 11V|||| |||**WORKING TEMP.**|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃|||| |||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| |||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH<br>℃|||| |||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 55<br>) on CH1 output|||| |||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||| |||**SAFETY STANDARDS**|UL62368-1, TUV BS EN/EN62368-1,<br>, AS/NZS 60950.1 approved<br>EAC TP TC 004|||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC|||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||| |||**EMC EMISSION**|Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020|||| |||**EMC IMMUNITY**|Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61204-3, light industry level,<br>EAC TP TC 020|||| |||**MTBF**|2496.2K hrs min.<br>Telcordia SR-332 (Bellcore) ; 536.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||| |||**DIMENSION**|40*90*100mm (W*H*D)|||| |||**PACKING**|0.3Kg; 42pcs/13.6Kg/0.82CUFT|||| |||1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>℃<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μ<br>μ<br>F<br>F<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.<br>5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed<br>that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power<br>supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded<br>permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.<br>7. The ambient temperature derating of 3.5<br>/1000m with fanless models and of 5<br>/1000m with fan models for operating altitude higher<br>℃<br>℃<br>than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>※<br>:||||| _File Name:DRC-40-SPEC 2024-01-26_ **DRC - 40 series** ## 40W Single Output with Battery Charger (UPS Function) ## **Block Diagram** **==> picture [471 x 353] intentionally omitted <==** **----- Start of picture text -----**<br> AC OK<br>ALARM<br>Bat. Low<br>CIRCUIT<br>EMI FILTER POWER RECTIFIERS +V<br>I/P & &<br>RECTIFIER SWITCHING -V<br>FILTER<br>Bat. +<br>DETECTION Bat. -<br>CIRCUIT<br>PWM<br>O.L.P. CONTROL Battery Charger<br>&<br>O.V.P. Back up Control<br>Derating Curve Static Characteristics<br>100<br>100<br>90<br>80<br>230VAC 80<br>Input only<br>60 70<br>60<br>40<br>50<br>20<br>40<br>-30 -20 0 15 30 40 50 55 60 70 (VERTICAL) 90 100 125 135 145 155 165 175 180 200 230 264<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:DRC-40-SPEC 2024-01-26_ **DRC - 40 series** 40W Single Output with Battery Charger (UPS Function) ## **Suggested Application** ## **1.Backup connection for AC interruption** ## (1) Please refer to Fig1.1 for suggested connection. The power supply charges the battery and provides energy to the load at the same time when AC mains is OK. The battery starts to supply power to the load when AC mains fails. **==> picture [122 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> A : 12V<br>B : 24V Load<br>Battery<br>+ - + -<br>Bat+ Bat- V+ V-<br>DC OK<br>+<br>+V ADJ<br>Fig 1.1 Suggested system connection<br>**----- End of picture text -----**<br> ## **2.Alarm signal for AC OK and battery low** - (1) Alarm signal is sent out through " AC OK " & " Battery Low " pins.(TTL open collector output is provided for standard model, and relay contact output is provided as optional model.) (2) An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 30mA. Please refer to Fig 2.2. - (3) Table2.1 explains the alarm function built in the power supply |Table2.1 explains|the alarm function built in the power supply|| |---|---|---| |Function|Description|Output of alarm| |AC OK|The signal is "Low" when the power supply turns ON.|Low (0.3V max. at 30mA)| ||The signal turns to be "High" when the power supply turns OFF.|High or open (External applied voltage 50V max.)| |Battery Low|The signal is "Low" when the voltage of battery is under A:11V, B:22V.|Low (0.3V max. at 30mA)| ||The signal is "High" when the voltage of battery is above A:11V, B:22V.|High or open (External applied voltage 50V max.)| |Table 2.1 Explanation of alarm signal||| AC OK (Battery low) **==> picture [143 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> PIN6(PIN8)<br>R<br>V<br>PIN5(PIN7)<br>External voltage and R<br>(The max. Sink is 30mA and 50V)<br>**----- End of picture text -----**<br> Fig 2.2 Internal circuit of AC OK (Battery Low), via TTL open collector _File Name:DRC-40-SPEC 2024-01-26_ **DRC - 40 series** 40W Single Output with Battery Charger (UPS Function) ## **Mechanical SpecificationMechanical Specification** **==> picture [83 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Case No.962A Unit:mm<br>**----- End of picture text -----**<br> **==> picture [492 x 503] intentionally omitted <==** **----- Start of picture text -----**<br> 40<br>3.81×7 100<br>8 7 6 5 4 3 2 1<br>TB2<br>DC OK<br>+<br>+V ADJ<br>TB1<br>3 2 1<br>7.5 7.5<br>Terminal Pin No. Assignment (TB1):<br>Pin No. Assignment<br>1 AC/L or DC+<br>2 AC/N or DC-<br>3 FG<br>Terminal Pin No. Assignment (TB2):<br>Pin No. Assignment Pin No. Assignment<br>1 -V 4 Bat. -<br>2 +V 5,6 AC OK<br>3 Bat. + 7,8 Bat. Low<br>Installation Instruction<br>This series fits DIN rail TS35/7.5 or TS35/15.<br>For installation details, please refer to the Instruction manual.<br>ADMISSIBLE DIN rail:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>Back View<br>Installation Manual<br>35<br>90<br>**----- End of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html _File Name:DRC-40-SPEC 2024-01-26_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →