Image not available
Illustrative purposes only
DRC-180B
AC/DC DIN Rail Power Supply (PSU), ITE & Industrial, 2 Output, 179.4 W, 27.6 V, 4.5 A, 27.6 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (25-Jun-2025)
- Product Range: DRC-180 Series
- No. of Outputs: 2 Output
- Output Power Max: 179.4W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 4.5A
- Output Current - Output 2: 2A
- Output Current - Output 3: -
- Output Voltage - Output 1: 27.6V
- Output Voltage - Output 2: 27.6V
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Industrial
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 61.32 € |
| Current stock | 10+ |
| Lead time | 30 days |
## 180W Single Output with Battery Charger(UPS Function) **DRC - 180 series** **==> picture [42 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> User’s Manual<br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧ - ‧ - ‧ - - ‧ ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ - - ‧ - ‧℃ - ‧ - ‧ ## ■ **** https://www.meanwell.com/serviceGTIN.aspx - ‧ - ‧ - ‧ ## ■ **** ℃ ℃ ## ■ **** ## **** ## **** _File Name:DRC-180-SPEC 2024-01-26_ > 180W Single Output with Battery Charger(UPS Function) **DRC - 180 series** ## **SPECIFICATION** |**SPECIFICATION**|**SPECIFICATION**|**SPECIFICATION**||||||| |---|---|---|---|---|---|---|---|---| |**EMC EMISSION**<br>**EMC IMMUNITY**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**PACKING**<br>**NOTE**<br>℃<br>μFμF<br><br><br>、<br>℃℃<br><br><br> <br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※:https://www.meanwell.com/serviceDisclaimer.aspx<br>63*125.2*115mm (W*H*D)<br>0.71Kg; 12pcs/10.5Kg/1.02CUFT<br>**OUTPUT**<br>**SAFETY STANDARDS**<br>UL62368-1, Dekra BS EN/EN62368-1,<br>, AS/NZS 62368.1 approved<br>EAC TP TC 004<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-20 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-20 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0~40℃) on CH1 output<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ALARM**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC OK Note.5**<br>**BATTERY LOW**<br>**AC CURRENT (Typ.)**<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>88%<br>2.5A/115VAC 1.5A/230VAC<br>COLD START 35A/115VAC 70A/230VAC<br><2mA / 240VAC<br>**FUNCTION**<br>Battery low voltage : < 11V<br>Battery low voltage : < 22V<br>Relay contact output, Closed : AC OK ; Open : AC Fail ; Max. rating : 30V / 1A<br>Relay contact output, Open : Battery OK ; Closed : Battery Low ; Max. rating : 30V / 1A<br>4.5A<br>0 ~ 6.5A<br>179.4W<br>4A(Battery charger)<br>--------<br>9A<br>0 ~ 13A<br>179.4W<br>**POWER FACTOR (Typ.)**<br>PF≧0.95/230VAC PF≧0.98/115VAC at full load<br>90%<br>**MODEL**<br>**DRC-180B**<br>**DRC-180A**<br>**DC VOLTAGE**<br>27.6V<br>CH1<br>13.8V<br>CH2<br>13.8V<br>CH1<br>**OUTPUT NUMBER**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME Note.4**<br>**HOLD UP TIME (Typ.)**<br>2000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load<br>20ms/230VAC 20ms/115VAC at full load<br>240mVp-p<br>CH1: 24 ~ 29V<br>±1.0%<br>±0.5%<br>±0.5%<br>--------<br>--------<br>--------<br>--------<br>150mVp-p<br>CH1: 12 ~ 15V<br>±1.0%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**BATTERY CUT OFF**<br>CH1:30.5 ~ 37.7V<br>20±1V<br>105 ~ 150% rated output power<br>CH1:15.8 ~ 19.5V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>10±0.5V<br>**PROTECTION**<br>2A(Battery charger)<br>--------<br>27.6V<br>CH2<br>--------<br>--------<br>--------<br>--------<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>Level 3, 8KV air ; Level 2, 4KV contact ;criteria A<br>Level 2, 3V/m ;criteria A<br>Level 2, 1KV ;criteria A<br>Level 3, 1KV/Line-Line 2KV/Line-Earth ;criteria A<br>Level 2, 3V ;criteria A<br>Level 1, 1A/m ;criteria A<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Conducted<br>**Parameter**<br>**Parameter**<br>Radiated<br>**Standard**<br>**Standard**<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>BS EN/EN55032(CISPR32)<br>BS EN/EN55032(CISPR32)<br>Class B<br>BS EN/EN55024<br>**OPERATING ALTITUDE Note.6**<br>**OVER VOLTAGE CATEGORY**<br>5000 meters / OVCⅡ<br>Ⅱ; According to Dekra BS EN/EN62368-1; altitude up to 5000 meters<br>**OVER TEMPERATURE**<br>Shut down o/p voltage, re-power on to recover<br>1536.3K hrs min. Telcordia SR-332 (Bellcore); 245.6K hrs min. MIL-HDBK-217F (25℃)||||||||| ||**EMC EMISSION**<br>**EMC IMMUNITY**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**PACKING**<br>**NOTE**<br>℃<br>μFμF<br><br><br>、<br>℃℃<br><br>63*125.2*115mm (W*H*D)<br>0.71Kg; 12pcs/10.5Kg/1.02CUFT<br>**OUTPUT**<br>**SAFETY STANDARDS**<br>UL62368-1, Dekra BS EN/EN62368-1,<br>, AS/NZS 62368.1 approved<br>EAC TP TC 004<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH<br>**SAFETY &**<br>**EMC**<br>**(Note 7)**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-20 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 90% RH non-condensing<br>-20 ~ +85℃, 10 ~ 95% RH non-condensing<br>±0.03%/℃(0~40℃) on CH1 output<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**ALARM**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC OK Note.5**<br>**BATTERY LOW**<br>**AC CURRENT (Typ.)**<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>88%<br>2.5A/115VAC 1.5A/230VAC<br>COLD START 35A/115VAC 70A/230VAC<br><2mA / 240VAC<br>**FUNCTION**<br>Battery low voltage : < 11V<br>Battery low voltage : < 22V<br>Relay contact output, Closed : AC OK ; Open : AC Fail ; Max. rating : 30V / 1A<br>Relay contact output, Open : Battery OK ; Closed : Battery Low ; Max. rating : 30V / 1A<br>4.5A<br>0 ~ 6.5A<br>179.4W<br>4A(Battery charger)<br>--------<br>9A<br>0 ~ 13A<br>179.4W<br>**POWER FACTOR (Typ.)**<br>PF≧0.95/230VAC PF≧0.98/115VAC at full load<br>90%<br>**MODEL**<br>**DRC-180B**<br>**DRC-180A**<br>**DC VOLTAGE**<br>27.6V<br>CH1<br>13.8V<br>CH2<br>13.8V<br>CH1<br>**OUTPUT NUMBER**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME Note.4**<br>**HOLD UP TIME (Typ.)**<br>2000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load<br>20ms/230VAC 20ms/115VAC at full load<br>240mVp-p<br>CH1: 24 ~ 29V<br>±1.0%<br>±0.5%<br>±0.5%<br>--------<br>--------<br>--------<br>--------<br>150mVp-p<br>CH1: 12 ~ 15V<br>±1.0%<br>±0.5%<br>±0.5%<br>**RIPPLE & NOISE (max.)Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>**BATTERY CUT OFF**<br>CH1:30.5 ~ 37.7V<br>20±1V<br>105 ~ 150% rated output power<br>CH1:15.8 ~ 19.5V<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage, re-power on to recover<br>10±0.5V<br>**PROTECTION**<br>2A(Battery charger)<br>--------<br>27.6V<br>CH2<br>--------<br>--------<br>--------<br>--------<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>Level 3, 8KV air ; Level 2, 4KV contact ;criteria A<br>Level 2, 3V/m ;criteria A<br>Level 2, 1KV ;criteria A<br>Level 3, 1KV/Line-Line 2KV/Line-Earth ;criteria A<br>Level 2, 3V ;criteria A<br>Level 1, 1A/m ;criteria A<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Conducted<br>**Parameter**<br>**Parameter**<br>Radiated<br>**Standard**<br>**Standard**<br>**Test Level / Note**<br>**Test Level / Note**<br>Class B<br>BS EN/EN55032(CISPR32)<br>BS EN/EN55032(CISPR32)<br>Class B<br>BS EN/EN55024<br>**OPERATING ALTITUDE Note.6**<br>**OVER VOLTAGE CATEGORY**<br>5000 meters / OVCⅡ<br>Ⅱ; According to Dekra BS EN/EN62368-1; altitude up to 5000 meters<br>**OVER TEMPERATURE**<br>Shut down o/p voltage, re-power on to recover<br>1536.3K hrs min. Telcordia SR-332 (Bellcore); 245.6K hrs min. MIL-HDBK-217F (25℃)||**DRC-180A**|||**DRC-180B**||| |||**OUTPUT NUMBER**|CH1|CH2||CH1||CH2| |||**DC VOLTAGE**|13.8V|13.8V||27.6V||27.6V| |||**RATED CURRENT**|9A|4A(Battery charger)||4.5A||2A(Battery charger)| |||**CURRENT RANGE**|0 ~ 13A|--------||0 ~ 6.5A||--------| |||**RATED POWER**|179.4W|||179.4W||| |||**RIPPLE & NOISE (max.)Note.2**|150mVp-p|--------||240mVp-p||--------| |||**VOLTAGE ADJ. RANGE**|CH1: 12 ~ 15V|||CH1: 24 ~ 29V||| |||**VOLTAGE TOLERANCE Note.3**|±1.0%|--------||±1.0%||--------| |||**LINE REGULATION**|±0.5%|--------||±0.5%||--------| |||**LOAD REGULATION**|±0.5%|--------||±0.5%||--------| |||**SETUP, RISE TIME Note.4**|2000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load|||||| |||**HOLD UP TIME (Typ.)**|20ms/230VAC 20ms/115VAC at full load|||||| |||**VOLTAGE RANGE**|90 ~ 264VAC 127 ~ 370VDC|||||| |||**FREQUENCY RANGE**|47 ~ 63Hz|||||| |||**POWER FACTOR (Typ.)**|PF≧0.95/230VAC PF≧0.98/115VAC at full load|||||| |||**EFFICIENCY (Typ.)**|88%|||90%||| |||**AC CURRENT (Typ.)**|2.5A/115VAC 1.5A/230VAC|||||| |||**INRUSH CURRENT (Typ.)**|COLD START 35A/115VAC 70A/230VAC|||||| |||**LEAKAGE CURRENT**|<2mA / 240VAC|||||| |||**OVERLOAD**|105 ~ 150% rated output power<br>Protection type : Hiccup mode, recovers automatically after fault condition is removed|||||| |||**OVER VOLTAGE**|CH1:30.5 ~ 37.7V<br>CH1:15.8 ~ 19.5V<br>Protection type : Shut down o/p voltage, re-power on to recover|||||| |||**OVER TEMPERATURE**|Shut down o/p voltage, re-power on to recover|||||| |||**BATTERY CUT OFF**|10±0.5V|||20±1V||| |||**AC OK Note.5**|Relay contact output, Closed : AC OK ; Open : AC Fail ; Max. rating : 30V / 1A|||||| |||**BATTERY LOW**|Battery low voltage : < 11V<br>Battery low voltage : < 22V<br>Relay contact output, Open : Battery OK ; Closed : Battery Low ; Max. rating : 30V / 1A|||||| |||**WORKING TEMP.**|-20 ~ +70℃(Refer to "Derating Curve")|||||| |||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||||| |||**STORAGE TEMP., HUMIDITY**|-20 ~ +85℃, 10 ~ 95% RH non-condensing|||||| |||**TEMP. COEFFICIENT**|±0.03%/℃(0~40℃) on CH1 output|||||| |||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||||| |||**OPERATING ALTITUDE Note.6**|5000 meters / OVCⅡ|||||| |||**OVER VOLTAGE CATEGORY**|Ⅱ; According to Dekra BS EN/EN62368-1; altitude up to 5000 meters|||||| |||**SAFETY STANDARDS**|UL62368-1, Dekra BS EN/EN62368-1,<br>, AS/NZS 62368.1 approved<br>EAC TP TC 004|||||| |||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC|||||| |||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH|||||| |||**EMC EMISSION**<br>**EMC IMMUNITY**<br>**MTBF**|**Parameter**||**Standard**||**Test Level / Note**|| ||||Radiated||BS EN/EN55032(CISPR32)||Class B|| ||||Conducted||BS EN/EN55032(CISPR32)||Class B|| ||||BS EN/EN55024|||||| ||||**Parameter**||**Standard**||**Test Level / Note**|| ||||ESD||BS EN/EN61000-4-2||Level 3, 8KV air ; Level 2, 4KV contact ;criteria A|| ||||Radiated||BS EN/EN61000-4-3||Level 2, 3V/m ;criteria A|| ||||EFT / Burst||BS EN/EN61000-4-4||Level 2, 1KV ;criteria A|| ||||Surge||BS EN/EN61000-4-5||Level 3, 1KV/Line-Line 2KV/Line-Earth ;criteria A|| ||||Conducted||BS EN/EN61000-4-6||Level 2, 3V ;criteria A|| ||||Magnetic Field||BS EN/EN61000-4-8||Level 1, 1A/m ;criteria A|| ||||Voltage Dips and Interruptions||BS EN/EN61000-4-11||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|| ||||1536.3K hrs min. Telcordia SR-332 (Bellcore); 245.6K hrs min. MIL-HDBK-217F (25℃)|||||| |||**DIMENSION**|63*125.2*115mm (W*H*D)|||||| |||**PACKING**<br>℃<br>μFμF<br><br><br>、<br>℃℃<br><br>0.71Kg; 12pcs/10.5Kg/1.02CUFT||||||| |||<br> <br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※:https://www.meanwell.com/serviceDisclaimer.aspx||||||| - (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) - ※:https://www.meanwell.com/serviceDisclaimer.aspx _File Name:DRC-180-SPEC 2024-01-26_ ## 180W Single Output with Battery Charger(UPS Function) **DRC - 180 series** ## **Block Diagram** **==> picture [504 x 593] intentionally omitted <==** **----- Start of picture text -----**<br> RL1 AC OK<br>ALARM<br>CIRCUIT<br>RL2 Bat. Low<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P RECTIFIER& CIRCUIT SWITCHING & -V<br>FILTER<br>Bat. +<br>FG O.T.P.<br>DETECTION Bat. -<br>CIRCUIT<br>PWM<br>O.L.P. CONTROL Battery Charger<br>&<br>O.V.P. Back up Control<br>Output Derating<br>100<br>80<br>70<br>60<br>50<br>20<br>-20 0 10 20 30 40 45 50 60 70 (Vertical)<br>AMBIENT TEMPERATURE ( ℃ )<br>Output Derating VS Input Voltage<br>100<br>90<br>80<br>70<br>60<br>50<br>40<br>90 95 100 115 120 140 160 180 200 220 240 264<br>INPUT VOLTAGE (VAC) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:DRC-180-SPEC 2024-01-26_ ## 180W Single Output with Battery Charger(UPS Function) **DRC - 180 series** ## **Suggested Application** ## **1.Backup connection for AC interruption** - (1) Please refer to the Fig1.1 for suggested connection. The power supply charges the battery and provides energy to the load at the same time when the AC main is OK. The battery starts to supply power to the load when the AC mains fails. Fig 1.1 Suggested system connection ## **2.Alarm signal for AC OK and Battery Low** (1) Alarm signal is sent out through " AC OK " & " Battery Low " pins.(relay contact type) (2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A. (3) Table2.1 explains the alarm function built in the power supply |Function|Description|Output of Alarm| |---|---|---| |AC OK|when the power supply turns ON|Closed| ||when the power supply turns OFF|Open| |Battery<br>Low|when the voltage of battery is under A:11V, B:22V|Closed| ||when the voltage of battery is above A:11V, B:22V|Open| Table 2.1 Explanation of Alarm Signal AC OK (Battery Low) TB3 Pin1(Pin3) R ~~K|||~~ V ~~|~~ | — ~~Lo~~ TB3 Pin2(Pin4) External voltage source (V) and resistor (R) (The max. Sink is 1A and 30V) Fig 2.2 Internal circuit of AC OK (Battery Low) (4) RL1 (AC OK)signal will go into hiccup mode when the overload protection is activating. _File Name:DRC-180-SPEC 2024-01-26_ ## 180W Single Output with Battery Charger(UPS Function) **DRC - 180 series** **==> picture [478 x 598] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>Case No. 979G Unit:mm<br>115<br>1 2 3 4 1 2 3 4<br>TB3 TB2<br>+V ADJ. +<br>DC OK<br>1 2 3<br>TB1<br>Terminal Pin No. Assignment (TB1)<br>Pin No. Assignment Terminal Pin No. Assignment (TB2)<br>1 FG Pin No. Assignment<br>2 AC/N 1 +V<br>3 AC/L 2 -V<br>3 Bat+<br>Terminal Pin No. Assignment (TB3) 4 Bat-<br>Pin No. Assignment<br>1,2 AC OK<br>3,4 Bat. Low <br>63<br>Installation Instruction<br>This series fits DIN rail TS35/7.5 or TS35/15.<br>For installation details, please refer to the Instruction manual.<br>ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>125.2<br>35<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:DRC-180-SPEC 2024-01-26_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →