DR6760D75RP
Solid State Relay, 75 A, 600 VAC, DIN Rail, Cage Clamp, Instantaneous Turn On
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA/CRYDOM
- Product type:
- SVHC: No SVHC (12-Jan-2017)
- Load Current: 75A
- Product Range: DR67 Series
- Relay Mounting: DIN Rail
- Switching Mode: Instantaneous Turn On
- Relay Terminals: Cage Clamp
- Control Voltage Max: 32VDC
- Control Voltage Min: 4VDC
- Contact Configuration: -
- Operating Voltage Max: 600VAC
- Operating Voltage Min: 48VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 418.55 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **DR67 SERIES | 60/75 AMPS** DIN RAIL MOUNT SOLID STATE RELAYS ## Introduction The DR67 is a compact 3-phase solid state relay in a DIN rail 67.5mm wide package with output ratings up to 75 Amps per channel @ 40°C. It has an integrated fan which allows the product to achieve very high ratings while maintaining a compact design. Its built-in overvoltage protection and the overtemperature protection make it suitable for demanding heating, motion and lighting applications. It’s easy to install and its large cage clamp terminals allow connecting wires up to 2 AWG size on the output terminals without the use of any additional accessories, therefore reducing installation cost and time. UL listed and VDE certified, the DR67 is a powerful and versatile solid state relay with superior performance when compared to previous generations and competitor products. ## Features - 3-Phase AC Output DIN Rail Mount SSRs - Output ratings up to 75 Amps at 600 VAC - 2 & 3 controlled Legs option - Built-in overvoltage protection - Clamp Cage terminal type accepts up to 2 AWG wire size - Fan controlled through thermistor and microprocessor to optimize fan operation - IP20 touch-safe housing - AC or DC control - cULus listed and VDE approved ## Applications - Plastic injection molding equipment - Packaging equipment - Industrial ovens - Lighting control - Professional cooking equipment - Pump control - Conveyor drives - HVAC&R ## **PRODUCT SELECTION** |**PRODUCT SELECTION**||| |---|---|---| |**Control Voltage**|60A|75A| |**4-32 VDC**|DR6760D60P|DR6760D75P| |**90-280 VAC/VDC**|DR6760A60P|DR6760A75P| Page 1 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **ORDERING OPTIONS** ## Example : DR6760A60RP Description of part number example |**Family**|**DR67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**|**DR67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**|**DR67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**|**DR67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**|**DR67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**|**DR67**<br>**60**<br>**x**<br>**xx**<br>**x**<br>**P**|| |---|---|---|---|---|---|---|---| ||||||||| ||||||||| |**Operating Volta**|**ge**||||||| |60 = 48-600 VAC|||||||| |**Control Voltage**|||||||| |D = 4-32 VDC<br>A = 90-280 VAC/VDC|||||||| |**Rated Load Curr**|**ent**||||||| |60 = 60A, 3-legs<br>75 = 75A, 2-legs|||||||| |**Switching Type**|||||||| |Blank = Zero voltage tu<br>R = Instantaneous turn|rn on<br>on||||||| |**Overvoltage Protection**<br>|**tection**||||||| ||||||||| |P = With internal overvoltage protection<br>Required for valid part number<br>For options only and not required for valid part<br>|||||||| |number|||||||| ## **SPECIFICATIONS** ## Output[(1)] **==> picture [541 x 273] intentionally omitted <==** **----- Start of picture text -----**<br> Description 60A 75A<br>Operating Voltage (47-440Hz) [VRMS] 48-600 48-600<br>Transient Overvoltage [Vpk] [(2)] 1200 1200<br>Maximum Off-State Leakage Current @ Rated Voltage 1 1<br>[mARMS]<br>Minimum Off-State dV/dt @ Maximum Rated Voltage [V/ 500 500<br>μsec]<br>Load Current, General Use UL508/LC A IEC62314 @ 40°C 60 75<br>[ARMS]<br>Load Current, Motor Starting UL508 FLA/LC B IEC62314 @ 21/17.6 21/17.6<br>40°C [ARMS]<br>Minimum Load Current [mARMS] 150 150<br>Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 1290/1350 1290/1350<br>Maximum On-State Voltage Drop @ Rated Current [VRMS] 1.15 1.20<br>Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 8320/7593 8320/7593<br>Minimum Power Factor (at Maximum Load) 0.5 0.5<br>Motor Rating UL 508: 120 VAC / 240 VAC / 480 VAC [HP] 3.0/5.0/15.0 3.0/5.0/15.0<br>Motor Rating IEC62314: 240 VAC / 400 VAC / 500 VAC [kW] 4.0/7.5/11.0 4.0/7.5/11.0<br>**----- End of picture text -----**<br> Page 2 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## Input[ (1)] **==> picture [541 x 160] intentionally omitted <==** **----- Start of picture text -----**<br> Description DR6760Dxxx DR6760Axxx<br>Control Voltage Range 4-32 VDC 90-280 VAC/VDC<br>Maximum Reverse Voltage -32 VDC -<br>Minimum Turn-On Voltage 4 VDC 90 VAC/VDC<br>Must Turn-Off Voltage 1 VDC 5 VAC/VDC<br>Minimum Input Current (for on-state) 0.8 mA 0.6 mA<br>Maximum Input Current 12 mA 2.8 mA<br>Nominal Input Impedance 3.2K ohms 120K ohms<br>Maximum Turn-On Time [msec] 20 [(3)]<br>Maximum Turn-Off Time [msec] 25<br>**----- End of picture text -----**<br> ## Power Supply[ (1)] **==> picture [541 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> Description DR6760Dxxx DR6760Axxx<br>Supply Voltage Range 18-32 VDC 90-280 VAC/VDC<br>Maximum Reverse Voltage -32 VDC -<br>Minimum Supply Current 3 mA 1.5 mA<br>Maximum Supply Current 130 mA 70 mA<br>**----- End of picture text -----**<br> ## Alarm[ (1)] **==> picture [541 x 65] intentionally omitted <==** **----- Start of picture text -----**<br> Description DR6760Dxxx DR6760Axxx<br>Output type Solid State<br>Maximum Output Voltage 60 VDC 400 VDC / 265 VAC<br>Maximum Alarm Output Current [mA] 60 60<br>**----- End of picture text -----**<br> ## General[(1)] **==> picture [541 x 304] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Dielectric Strength, Input to Output (50/60Hz) 4k VRMS<br>Dielectric Strength, Input/Output to Case (50/60Hz) 4k VRMS<br>Minimum Insulation Resistance (@ 500 VDC) 10 [9] Ohms<br>Maximum Capacitance, Input/Output 25pF<br>Ambient Operating Temperature Range -40 to 70°C<br>Ambient Storage Temperature Range -40 to 80°C<br>Short Circuit Current Rating [(4) ] 100 kA<br>Weight (typical) 33.9 oz (961 g)<br>Housing Material UL94 V-0<br>Heat Sink Material Aluminum<br>DIN Rail Clip Material Zinc Plated Steel<br>Hardware Finish Nickel Plating<br>Input Terminal Screw Torque Range (lb-in/Nm) 5/0.5<br>Load Terminal Screw Torque Range (lb-in/Nm) 18-20/2.0-2.2<br>Humidity per IEC 60068-2-78 [(5)] 93%<br>LED Input Status Indicator See status chart<br>Overvoltage Category III<br>Impulse Withstand Voltage According to IEC 60664-1 6kV Page 3<br>**----- End of picture text -----**<br> Copyright © 2019 Sensata Technologies, Inc. www.sensata.com **EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS** ## **DR6760X60 DR6760X75** **==> picture [526 x 637] intentionally omitted <==** **----- Start of picture text -----**<br> 48-600 VAC, 47-440 Hz<br>L1 L1<br>L2 L2<br>L3 L3<br> Short circuit and overload<br>current protection<br>/ > / > / ><br>1/L1 3/L2 5/L3<br>POWER L1 L2 L3<br>SUPPLY<br>T1 T2 T3<br>ALARM INPUT<br>OUTPUT A1 A2 A3 A4 A5 A6 CONTROL<br>INPUT<br>2/T1 4/T2 6/T3<br>Motor Controller T1 T2 T3 General Use<br>Application Application<br>T1 T2 T3 T1 T2 T3<br>M<br>3<br>DR6760X75 DR6760X60<br>(2 CONTROLLED LEGS ) (3 CONTROLLED LEGS )<br>ALARM ALARM<br>MAIN CIRCUIT MAIN CIRCUIT<br>OUTPUT OUTPUT<br>L1 L2 L3 +A1 +A3 A5 L1 L2 L3 +A1 +A3 A5<br>T1 T2 T3 -A2 -A4 A6 T1 T2 T3 -A2 -A4 A6<br>48-600VAC<br>PWR SUPPLY 18-32VDC INPUT CTRL 4-32VDC ALARM OUTPUT<br>U+ U- A1+ A2- B1<br>**----- End of picture text -----**<br> Page 4 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **MECHANICAL SPECIFICATIONS** Tolerances: ±0.02 in / 0.5 mm All dimensions are in inches [mm] **==> picture [337 x 642] intentionally omitted <==** **----- Start of picture text -----**<br> 2.66<br>67.5<br>1.11<br>28.2<br>4X .87<br>22.2<br>1/L1 3/L2 5/L3<br>L1 L2 L3<br>3.61 T1 T2 T3 INPUT<br>91.8<br>5.00<br>127<br>2/T1 4/T2 6/T3<br>1.45<br>36.8<br>5.12<br>130.1<br>5.82<br>147.8<br>48-600VAC<br>PWR SUPPLY 18-32VDC INPUT CTRL 4-32VDC ALARM OUTPUT<br>U+ U- A1+ A2- B1<br>**----- End of picture text -----**<br> Page 5 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **SURGE CURRENT INFORMATION[(6)]** ## 60A & 75A ## **THERMAL DERATE INFORMATION** ## **STATUS CHART** ## **60A & 75A MODELS** |**Conditions**|**Conditions**|**Description**|**Description**|| |---|---|---|---|---| ||1,16|Initial Condition.||| ||2<br>3, 5, 15<br>4, 6, 14|Microcontroller Start-up,white light.<br>Stand by condition, LED is blinking blue.<br>Control Input is Off.<br>Control Input is On, Output is activated,<br>temperature rises, Green LED is On, Fan<br>goes to Maximum speed and then starts<br>regulatingthe speed for optimal values.||| ||7|LED indicator changes to blinking red,<br>fan is at full speed.||| ||8, 11|Output is Off due to overtemperature,<br>alarm is On,LED changes to solid red||| |||While Power Supply is Off: Output,||While Power Supply is Off: Output,| ||9|Alarm, LED and Fan remains Off. (Power<br>SupplyMin. 100ms to reset values)||| ||10|Power Supply is On, start initialization.<br>Control Input is On, Output is on and||| ||12|temperature rises.<br>Control Input is On, Output is Off due to<br>overtemperature.<br>Blue<br>Standby mode||| ||||LED<br>Green|Output On| ||||Color<br>Red|Alarm| ||||White|Initialization| Page 6 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **INSTALLATION INSTRUCTIONS** ## **Mounting on DIN Rail** - Locate rail and align with non moveable end of DR67 DIN clip. - Using reasonable force, push DR67 in the direction of the arrow (as shown in fig.1). - For removal pull release tag by moving blade of screwdriver in direction of arrow and pull it away from DIN rail. - For models with integrated fan removal tool must be inserted from the side (as shown in fig. 2) ## **Wiring Instructions** - Recommended wire sizes as shown in TABLE 1 - Maximum terminal screw torque input terminal 5 lb-in (0.5 Nm) (screw terminal only) - Maximum terminal screw torque load terminal 18-20 lb-in (2.0-2.2 Nm) - Strip lenght for input terminals: Per manufacturer specifications - Strip lenght for load terminals: 10mm min. - Use only copper conductors rated for 75°C - If multiple units are installed be sure to follow derating curves. **==> picture [87 x 158] intentionally omitted <==** **----- Start of picture text -----**<br> Push to install on<br>DIN rail<br>sY :p<br>fig.1 SSR mounted on DIN rail<br>fig.2 Removal of SSR with Fan<br>Pull to remove from DIN rail<br>**----- End of picture text -----**<br> ## **WARNING!!** - Removing product from 35mm Rail incorrectly by not using the appropriate tool, would damage the latching system. ## **Table 1. Wire Size & Pull Out Strength** **==> picture [331 x 101] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Terminal Configuration|Recommended Wire Size (Solid/Stranded)|Wire Pull-Out Strength (lb)[N]*| |1 x 18 AWG (1 mm|[2]|) [minimum]|20 [88]| |1 x 8 AWG (10 mm|[2]|)|75 [333]| |Output| |2 x 8 AWG (10 mm|[2]|)|65 [289]| |1 x 3 AWG (26.67 mm|[2]|)|[(1)]|90 [400]| |30 AWG (0.05 mm|[2]|) [minimum]|4.5 [20]| |Input|Screw| |12 AWG (3.3 mm|[2]|) [maximum]|30 [133]| **----- End of picture text -----**<br> *Tests performed on Stranded wire (1) Maximum wire size 1 x 2 AWG (35mm2), torque 24 lb-in (2.7 Nm) & strip lenght 12.7mm min. ## **ACCESSORIES** **Recommended Accessories ID Marker** CNLB CNLN CNL2 ## **Protective Earth Connection** Protective earth (PE) screw type recommended is 1032 UNC standard not provided with SSR. Through the use of a DIN rail ground (protective conductor) terminal block, the DIN rail itself can be used as the grounding bus bar. In this case, the zinc plated steel material used for the DIN rail clip of DR67 models, permits a secure path to ground and avoid the need of a further PE connection. 10-32Thread Page 7 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com **AGENCY APPROVALS & CERTIFICATIONS** **Approvals (Tested and Certified According To)** 40047491 E116949 UL 508 and EN 62314 C22.2 No. 14 ~~1 ao~~ **CONFORMANCES ENVIRONMENTAL** ~~es~~ **Vibration Shock ResisResistances to Resistance IEC tance IEC IEC heat and fire 60068-2-6[(7)] 60068-2-27[(7)]** ~~Ee~~ Amplitude Range: Peak Acceleration: IEC 60335-1, Directive Directive 10-55 Hz, DisplaceGBT 26572-2011 15g, Duration 11ms. Section 30 2006/95/EC 2011/65/EU ment 0.75mm ~~| | | ft~~ **Electromagnetic Compatibility** ~~ee~~ **Generic Standard Immunity Tests Test Specification Level Performance** Electrostatic Discharge 8kV air dischar ~~ee~~ ge Criterion A ~~es~~ IEC 61000-4-2 6kV contact discharge Criterion A Fast transient (burst) Output 2kV, 5kHz, 100kHz ~~eee~~ Criterion B ~~q~~ IEC 61000-4-4 Input ~~m~~ 1kV, 5kHz, 100kHz Criterion B IEC 61000-6-2 1kV Line to Line Criterion B Immunity for Industrial EnviOutput ronments" Surge 2kV Line to Earth Criterion B IEC 61000-4-5 1kV Line to Line Criterion A AC Input Option 2kV Line to Earth Criterion A ~~——a~~ ~~**e** seeee~~ **GENERAL NOTES** @ (1) All parameters at 25°C unless otherwise specified per Channel. (2) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads. (3) Turn-on time for Instantaneous turn-on versions is 0.3 msec. (4) When protected with the appropriate class and rated fuse. For detailed info please contact Sensata Technical Support. (5) No freezing or condensation allowed. (6) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by 2 (1.414). (7) Test conditions: Din Rail stoppers side by side between a single SSR. Page 8 Copyright © 2019 Sensata Technologies, Inc. www.sensata.com ## **WARNINGS** RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** ## HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 9 Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.com Rev.08/09/19 ERN 20741 FDE-07-01 Rev.B Copyright © 2019 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →