Image not available
Illustrative purposes only
DR24A12
SOLID STATE RELAYS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA-CRYDOM / PARTNER STOCK
- Product type:
- SVHC: No SVHC (21-Jan-2025)
- Product Range: SeriesOne DR Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 98.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **SERIESONE DR SERIES | AC OUTPUT** DIN RAIL MOUNT SOLID STATE RELAYS Sensata | Crydom SeriesOne DR family of DIN Rail mount Solid State Relays incorporate proprietary thermal management technology to achieve exceptional output ratings of 3, 6 and 12 Amps at 24 to 600 VAC in compact 11mm and 18mm wide housings. These compact SSRs are ideal for use in demanding applications where space may be limited, providing greater power density than other DIN Rail Solid State Relays. ## Features - Ratings of 3, 6 & 12 Amps - Load voltage ratings of 24-280 VAC and 48-600 VAC - Fits standard 35mm DIN Rail - LED input status indicator - AC or DC control - Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output - UL and cUL Listed, HP Rated, CE & RoHS Compliant - UL 508 Endurance Rating for Enhanced Reliability - UL Class I and II, Division 2, for Hazardous Locations ## Applications - Industrial ovens **==> picture [35 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> 3, 6 Amps<br>**----- End of picture text -----**<br> - Plastic injection molding equipment - Packaging equipment - Professional cooking equipment - Lighting control - HVAC&R 12 Amps ## **PRODUCT SELECTION** |**Control Voltage**<br>~~es~~|**280V, 3 A**<br>~~es~~|**280V, 6 A**<br>~~es~~|**280V, 12 A**<br>~~es~~|**600V, 3 A**<br>~~es~~|**600V, 6 A**<br>~~es~~|**600V, 12 A**<br>~~es~~| |---|---|---|---|---|---|---| |**4-32 VDC**<br>~~es~~<br>~~**a**~~|DR24D03<br>~~es~~<br>~~**a**~~|DR24D06<br>~~es~~<br><br>~~a~~|DR24D12<br>~~es~~<br><br>~~a~~|DR48D03<br>~~es~~<br>|DR48D06<br>~~es~~<br>|DR48D12<br>~~es~~<br>| |**90-140 VAC**<br>~~**a**~~|DR24B03<br>~~**a**aa~~|DR24B06<br>~~aa~~<br>~~a~~|DR24B12<br>~~aa~~<br>~~a~~|~~aa~~|~~aa~~|DR48B12<br>~~aa~~| |**200-280 VAC**<br><br>~~aaa~~|DR24A03<br>~~aa~~|DR24A06<br>~~aa~~<br>~~a ~~<br>a|DR24A12<br>~~aa~~<br> ~~a~~<br>~~a~~|~~aa~~<br>~~es~~|~~aa~~|DR48A12<br>~~aa~~| |**18-36 VAC**<br>~~aaa~~|DR24E03|DR24E06<br>a|DR24E12<br>~~a~~|~~es~~||DR48E12| Page 1 www.sensata.com Copyright © 2021 Sensata Technologies, Inc. ## **SPECIFICATIONS** ## Output[(1)] **==> picture [542 x 370] intentionally omitted <==** **----- Start of picture text -----**<br> Description DR24x03 DR24x06 DR24x12 DR48x03 DR48x06 DR48X12<br>Operating Voltage Range (47-63Hz) [Vrms] 24-280 24-280 24-280 48-600 48-600 48-600<br>Transient Overvoltage [Vpk] 600 600 600 1200 1200 1200<br>Maximum Load Current, resistive [Arms] [(2)] 3 6 12 3 6 12<br>Minimum Load Current [mArms] 150 150 150 150 150 150<br>Maximum Off-State Leakage Current @<br>0.1 0.1 0.1 0.1 0.1 0.1<br>Rated Voltage [mArms]<br>Minimum Off-State dv/dt @ Maximum<br>500 500 500 500 500 500<br>Rated Voltage [V/μsec] [ (3)]<br>Maximum On-State Voltage Drop @ Rated<br>1.3 1.3 1.3 1.3 1.3 1.3<br>Current [Vrms]<br>Maximum Surge Current (50/60Hz, 1 cycle)<br>285/300 285/300 715/750 285/300 285/300 715/750<br>[Apk]<br>Maximum I²t for Fusing (50/60 Hz, 1/2 cycle)<br>410/375 410/375 2560/2330 410/375 410/375 2560/2330<br>[A² sec]<br>HP Rating UL 508/IEC60947 [HP (KW)] @<br>1/4 (.18) 1/2 (.37) 1 (.75) 1.4 (.18) 1/2 (.37) 1 (.75)<br>240V<br>HP Rating UL 508/IEC60947 [HP (KW)] @<br>N/A 1 (.75) 2 (1.5) 1/3 (.25) 1 (1.5) 2 (1.5)<br>380V<br>HP Rating UL 508/IEC60947 [HP (KW)] @<br>N/A N/A 3 (2.2) 1/2 (.37) 2 (1.5) 3 (2.2)<br>480V<br>Minimum Power Factor (at Maximum Load) 0.5 0.5 0.5 0.5 0.5 0.5<br>Min/Max stranded wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG<br>Min/Max solid wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG<br>Weight (Typical) 1.76 oz (50 g) 1.76 oz (50 g) 3.17 oz. (90g) 1.76 oz (50 g) 1.76 oz (50 g) 3.17 oz. (90g)<br>**----- End of picture text -----**<br> ## Input[(1)] **==> picture [542 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> Description DRxxDxx DRxxBxx DRxxAxx DRxxExx<br>Control Voltage Range [(3)] 4-32 VDC 90-140 Vrms 200-265 Vrms 18-36 Vrms [(5)]<br>Minimum Turn-On Voltage 4.0 VDC 90 Vrms 200 Vrms 18 Vrms<br>Must Turn-Off Voltage 1.0 VDC 10 Vrms 40 Vrms 4 Vrms<br>Minimum Input Current for [mA] [(4)] 9 3 2.5 3.5<br>Maximum Input Current for [mA] [(4)] 11 5 3.3 8<br>Maximum Turn-on Time [msec] [(5)] 1/2 Cycle 20 msec 20 msec 20 msec<br>Maximum Turn-off Time [msec] 1/2 Cycle 30 msec 30 msec 30 msec<br>Min/Max stranded/solid wire 22/16 AWG 22/16 AWG 22/16 AWG 22/16 AWG<br>**----- End of picture text -----**<br> Page 2 www.sensata.com Copyright © 2021 Sensata Technologies, Inc. ## General[(2)] **==> picture [265 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Description|Parameters| |Dielectric Strength, Input/Output/Base|4000 Vrms| |(50/60Hz)| |Minimum Insulation Resistance (@ 500 V|10|[9]|Ohms| |DC)| |Maximum Capacitance, Input/Output|10 pF| |Ambient Operating Temperature Range|-30 to 80 °C| |Ambient Storage Temperature Range|-30 to 100 °C| |Recommended Terminal Screw Torque|4.4-7.0 lb-in (0.5-0.8 Nm)| |Range| **----- End of picture text -----**<br> ## **MECHANICAL SPECIFICATIONS[(1)]** **3 A , 6 A 12 A** ## **EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS** Page 3 www.sensata.com Copyright © 2021 Sensata Technologies, Inc. ## **THERMAL DERATE INFORMATION** **==> picture [211 x 149] intentionally omitted <==** **==> picture [212 x 174] intentionally omitted <==** Single and multiple units (for DRxxx03) Single unit, distance to adjacent components ≥ 11 mm for DRxxx06 and ≥ 18 mm for DRxxx12 Multiple units, no minimum spacing between components ## **STANDARDS OF COMPLIANCE** ## **IEC 62314** LC A, Resistive or Slightly Inductive Load Ratings: 3A @40°C ambient for DR24x03, 3A @ 40°C ambient for DR48x03 LC A, Resistive or Slightly Inductive Load Ratings: 12 A @40°C ambient for DR24x12, 12 A @ 40°C ambient for DR48x12 LC A, Resistive or Slightly Inductive Load Ratings: 6 A @ 40°C ambient for DR24x06, 6 A @ 40°C ambient for DR48x06 LC B, Motor Loads Ratings: 0.18KW @ 240VAC for DR24x03 and 0.375KW @ 480VAC DR48x03 LC B, Motor Loads Ratings: 0.75KW @ 240 VAC for DR24x06 and 2.2KW @ 480 VAC DR48x12 LC B, Motor Loads Ratings: 0.375KW @ 240 VAC for DR24x06 and 1.5KW @ 480 VAC DR48x12 ## **Shock and Vibration (Applies to all part numbers)** Vibration Resistance according to IEC 60068-2-6: **0.35mm and 0.75mm Amplitude over 10-55 Hz** Shock Resistance according to IEC 60068-2-27: **15g/11ms** **EMC** (Applies to all part numbers) IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ## **ANSI / ISA 12.12.01-2013** Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for Class I, Division 2 Page 4 www.sensata.com Copyright © 2021 Sensata Technologies, Inc. **ORDERING OPTIONS** Example : DR24D12R @ **DR 24 D 12 X R** ~~| | Ld~~ **Series** ~~=~~ **DR Operating Voltage 24:** 24-280 VAC esee **48:** 48-600 VAC **Control Voltage** pp **D:** 4-32 VDC **A:** 200-265 VAC **B:** 90-140 VAC **E:** 18-36 VAC **[(1)] Rated Load Current** ee **03:** 3 Amps **06:** 6 Amps **12:** 12 Amps **ATEX Approvals Blank:** Not ATEX approved **X:** ATEX II 3G Ex nA IIC T4 Gc approved **Switching Type Blank:** Zero Voltage Turn-On Required for valid part number ~~a~~ **R** : Instantaneous Turn-On (D suffix Only) For options only and not required for valid part number ## **GENERAL NOTES** ~~©~~ (1) All parameters at 25°C unless otherwise specified. - (2) See Derating curves > (3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 > (4) DC control includes reverse polarity protection. > (5) E option is UL certified for AC control voltage, but it works also with 18-36 VDC input range. > (6) Input circuitry incorporates active current limiter. > (7) Turn-on time for DC control random turn-on versions is 0.1 msec. ## **AGENCY APPROVALS & CERTIFICATIONS** © Page 5 www.sensata.com Copyright © 2021 Sensata Technologies, Inc. **ACCESSORIES** ## **ID Marker Strips** ## **CNLB, CNLN, CNL2** **==> picture [523 x 76] intentionally omitted <==** **----- Start of picture text -----**<br> Black Strips Numbered 1 to 10 Strips Numbered 11 to 20 Strips<br>Part no.: CNLB Part no.: CNLN Part no.: CNL2<br>A package of 10 plastic strips comprising 10 A package of 10 plastic strips comprising 10 A package of 10 plastic strips comprising 10<br>individual unprinted markers which can be placed markers printed individually from 1 to 10 which markers printed individually from 11 to 20 which<br>on sockets’ terminal block for easy identification can be placed on sockets’ terminal block for easy can be placed on sockets’ terminal block for easy<br>during the use of multiple units. identification during the use of multiple units. identification during the use of multiple units.<br>**----- End of picture text -----**<br> ## **WARNINGS** - RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE • The product’s side panels may be hot, allow the product to cool before touching • Follow proper mounting instructions including torque values • Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH • Disconnect all power before installing or working with this equipment • Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 6 Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.com Rev:05/28/2021 ECN 21137 FDE-07-01 Rev. B Copyright © 2021 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →