Image not available
Illustrative purposes only
DR2224D30U
Solid State Relay, 30 A, 280 VAC, DIN Rail, Screw, Zero Voltage Turn On
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA/CRYDOM
- Product type:
- SVHC: No SVHC (12-Jan-2017)
- Load Current: 30A
- Product Range: DR22 Series
- Relay Mounting: DIN Rail
- Switching Mode: Zero Voltage Turn On
- Relay Terminals: Screw
- Control Voltage Max: 32VDC
- Control Voltage Min: 3VDC
- Contact Configuration: -
- Operating Voltage Max: 280VAC
- Operating Voltage Min: 24VAC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 56.71 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **DR22 SERIES | AC OUTPUT LOW-PROFILE** DIN RAIL MOUNT SOLID STATE RELAYS Nova22 DR22 Series are last generation DIN Rail mount Solid State Relays in a 22.5mm wide industrial package. “Low-profile” versions come with an integral low-profile heat sink and a TRIAC output rated for up to 30 Amps at 280 VAC. This provides users with a cost-effective solution to switch small and medium AC loads that allows to reduce manufacturing cost and cabinet space without sacrificing performance, and to optimize equipment operation time. These powerful and ready to use SSRs are perfect for applications where the depth of the control panel is limited, and they are UL approved and CE compliant. ## Features - Output ratings up to 30 Amps at 280 VAC - Relay configuration - Compact 22.5 mm wide package - Snubber circuit - Built-in overvoltage protection - IP20 touch-safe housing - Wide 3-32 VDC control input - Integrated low-profile heatsink - C-UL-US approved ## Applications - Industrial ovens - Plastic injection molding equipment - Packaging equipment - Professional cooking equipment - Lighting control - HVAC&R ## **PRODUCT SELECTION** |**Control Voltage**|**20 A**|**30 A**| |---|---|---| |**3-32 VDC**|DR2224D20Ux|DR2224D30Ux| ## **SPECIFICATIONS** Output[ (1)] ~~a~~ **Description 20 A 30 A Operating Voltage (47-63 Hz) [Vrms]** 24-280 24-280 ~~BP~~ **Transient Overvoltage [Vpk][ (2)]** 600 600 ~~PR~~ **Minimum Off-State dV/dt @ Maximum Rated Voltage [V/μsec]** 500 500 ~~Re~~ **Maximum Off-State Leakage Current @ Rated Voltage [mArms]** 3 3 ~~PO i~~ **Load Current, General Use UL508 @40°C [Arms]** 20 30 **Load Current, Motor Starting UL508 FLA @40°C [Arms]** 9.8 13.8 ~~PR Ee ee~~ **Minimum Load Current [mArms]** 100 100 ~~PO~~ **Maximum 1 Cycle Surge Current (50/60 Hz) [Apk]** 400/440 **Maximum On-State Voltage Drop @ Rated Current [Vpk]** 1.2 1.3 Page 1 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. |**Maximum 1/2 Cycle I²t for Fusing (50/60Hz) [A²sec]**|800/806|800/806| |---|---|---| |**Motor Rating UL 508 [HP (kW)]: 120 VAC**|0.5 (0.37)|0.75 (0.55)| |**Motor Rating UL 508 [HP (kW)]: 240 VAC**|1.5 (1.1)|2 (1.5)| ## Input[ (1)] **==> picture [541 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> Description DR2224Dxxxx<br>Control Voltage Range [VDC] [(3)] 3-32<br>Minimum Turn-On Voltage [VDC] 3<br>Must Turn-Off Voltage [VDC] 1<br>Minimum Input Current (for on-state) [mA] 8<br>Maximum Input Current [mA] 15<br>Nominal Input Impedance Current Regulated<br>Maximum Turn-On Time [(4)] 1/2 Cycle<br>Maximum Turn-Off Time 1/2 Cycle<br>Maximum Turn-Off Time [μsec] 100<br>**----- End of picture text -----**<br> ## General[ (1)] **==> picture [542 x 241] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Dielectric Strength, Input to Output (50/60 Hz) 3750 Vrms<br>Dielectric Strength, Input/Output to Case (50/60 Hz) 2500 Vrms<br>Minimum Insulation Resistance (@ 500 VDC) 10 [9] Ohms<br>Maximum Capacitance, Input/Output 8 pF<br>Ambient Operating Temperature Range -40 to 80 °C<br>Ambient Storage Temperature Range -40 to 100 °C<br>Weight (typical) 9.17 oz (260 g)<br>Housing Material UL94 V-0<br>Heat Sink Material Aluminum<br>DIN Rail Clip Material Zink Plated Steel<br>Hardware Finish Nickel Plating<br>Humidity 95% non-condensing<br>Input and Output Terminal Screw Torque Range (lb-in/Nm) 13-15 / 1.5-1.7<br>LED Input Status Indicator Green<br>**----- End of picture text -----**<br> Page 2 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **INPUT CURRENT INFORMATION** **==> picture [60 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> 4-32 VDC Input<br>**----- End of picture text -----**<br> **==> picture [281 x 147] intentionally omitted <==** ## **SURGE CURRENT INFORMATION** **==> picture [442 x 192] intentionally omitted <==** **----- Start of picture text -----**<br> 500<br>ITSM IT ITSM<br>(A)<br>400 t<br>T<br>T j(init) = 25 ˚C max<br>300<br>200<br>100<br>0<br>1 1 00 1 2 10 [3]<br>number of cycles (n)<br>f = 50 Hz<br>**----- End of picture text -----**<br> Non-repetitive peak on-state current as a function of the number of sinusoidal current cycles; maximum values. ## **THERMAL DERATE INFORMATION** **==> picture [221 x 174] intentionally omitted <==** **==> picture [50 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> Single units [ (5)]<br>**----- End of picture text -----**<br> **==> picture [226 x 178] intentionally omitted <==** Multiple units, no minimum spacing between components Page 3 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM** Load can be wired to either terminal 1 or terminal 2. |**Recommended Wire Sizes**|**Recommended Wire Sizes**|**Recommended Wire Sizes**| |---|---|---| |**Terminal**<br>**Configuration**|**Wire Size**<br>**(Solid / Stranded)**|**Wire Pull-Out**<br>**Strength (lb)[N]**| |**Configuration**<br>**Output**<br>**Relay “U” suffix**|**(Solid / Stranded)**<br>2 x 18 AWG (1 mm2) Stranded|**Strength (lb)[N]**<br>20 [88]| ||2 x 10 AWG (6 mm2) Stranded|60 [266]| |**Input**<br>**Relay “U” suffix**|2 x 18 AWG (1 mm2) Stranded|20 [88]| ||2 x 12 AWG (4 mm2) Stranded|40 [177]| ## **MECHANICAL SPECIFICATIONS** *Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] **==> picture [114 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> Protective Earth Connection<br>So<br>10-32<br>- Thread<br>**----- End of picture text -----**<br> Protective Earth (PE) Screw Type recommended is 10-32 UNC standard not provided With SSR. Through the use if a DIN rail ground (protective conductor_ Therminal block, the DIN rail clip of DR22 models, permits as secure path to ground and avoid the need of further PE protection. |**Compatible Terminal**<br>~~PO~~|**Compatible Terminal**<br>~~PO~~| |---|---| |**Terminal**|W<br>D<br>**Fork Lug**<br>~~a~~i)| |**Width [W] in (mm)**|0.45 (11.4)| |**Stud Size Dia [D] (in)**|#8 (0.168)| ## **ACCESSORIES** **==> picture [114 x 102] intentionally omitted <==** **----- Start of picture text -----**<br> Recommended Accessories<br>ID Marker<br>CNLB<br>CNLN<br>CNL2<br>**----- End of picture text -----**<br> Page 4 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. **AVAILABLE OPTIONS** Example : DR2224D20UR We **DR22 24 D 20 U R Series** ~~_|~~ **DR22 Operating Voltage** ee **24:** 24-280 VAC **Control Voltage** ee **D:** 3-32 VDC **Rated Load Current 20:** 20 Amps **30:** 30 Amps **Terminal Layout U:** Relay Configuration **Switching Type Blank:** Zero Voltage Turn-On Required for valid part number ~~a~~ **R:** Instantaneous Turn-On (Motor Rating Certified) For options only and not required for valid part number ## **GENERAL NOTES** ~~©~~ > **(1) All parameters at 25°C unless otherwise specified. (2) Internal protection will activate between 440-540 Vpk, intended to protect power semiconductor for high frequency transient only. Internal damage can occur if device is operated beyond voltage limits.** - **(3) Increase minimum voltage by 1 V for operations from -20 to -40°C.** - **(4) Turn-on time for instantaneous turn-on versions is 0.1 msec.** > **(5) Minimum spacing to obtain maximum current is 22.5mm between adjacent units.** ## **AGENCY APPROVALS & CERTIFICATIONS** @ Certification in accordance with: United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. |**Electromagnetic Compatibility**|**Electromagnetic Compatibility**|**Electromagnetic Compatibility**|**Electromagnetic Compatibility**|**Electromagnetic Compatibility**| |---|---|---|---|---| |**Generic Standard**|**Inmunity Tests**|**Test Specification Level**||**Performance**| |IEC 61000-6-2<br>Immunity for Industrial Environments|Electrostatic Discharge<br>IEC 61000-4-2|4kV air discharge||Criterion A| |||4kV contact discharge||Criterion A| ||Fast transients (burst)<br>IEC 61000-4-4|Output|2kV, 5kHz, 100kHz|Criterion B| |||Input|1kV, 5kHz, 100kHz|Criterion B| ||Surge<br>IEC 61000-4-5|Output|1kV Line to Earth|Criterion B| ||||2kV Line to Earth|Criterion B| Page 5 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. ## **WARNINGS** RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 09/02/2021 ECN 21163 FDE-07-01 Rev. B Page 6 Copyright © 2020 Sensata Technologies, Inc. www.sensata.com
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →