Image not available
Illustrative purposes only
DR10D10
Solid State Relay, 10 A, 100 VDC, DIN Rail, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA/CRYDOM
- Product type:
- SVHC: No SVHC (12-Jan-2017)
- Load Current: 10A
- Product Range: SeriesOne DR Series
- Relay Mounting: DIN Rail
- Switching Mode: -
- Relay Terminals: Screw
- Control Voltage Max: 32VDC
- Control Voltage Min: 4VDC
- Contact Configuration: -
- Operating Voltage Max: 100VDC
- Operating Voltage Min: 1VDC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 67.63 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **SERIESONE DR SERIES | DC OUTPUT** DIN RAIL MOUNT SOLID STATE RELAYS Sensata | Crydom SeriesOne DR family of DIN Rail mount Solid State Relays incorporate proprietary thermal management technology to achieve exceptional output ratings of 3 up to 24 Amps at 1 to 100 VDC in compact 11mm and 18mm wide housings. These compact SSRs are ideal for use in demanding applications where space may be limited, providing greater power density than other DIN Rail Solid State Relays. ## Features - Ratings from 3 up to 24 Amps - Load voltage ratings of 1-60 VDC and 1-100 VDC - Fits standard 35mm DIN Rail - LED input status indicator - DC control - UL and cUL Listed, CE & RoHS Compliant - UL 508 Endurance Rating for Enhanced Reliability - UL Class I and II, Division 2, for Hazardous Locations ## Applications - Battery Management Systems - Backup Power Supplies **==> picture [53 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> 3, 6 & 10 Amps<br>**----- End of picture text -----**<br> - Valve Control - Lighting control - Automation Equipment 12 & 24 Amps ## **PRODUCT SELECTION** |**Control Voltage**<br>~~es~~<br>~~[a~~|**60V, 3 A**<br>~~es~~<br>~~[a~~|**60V, 6 A**<br>~~es~~|**60V, 12 A**<br>~~ss~~|**100V, 3 A**<br>~~ss~~|**100V, 6 A**|**100V, 10A**|**100V, 12A**|**100V, 24 A**| |---|---|---|---|---|---|---|---|---| |**4-32 VDC**<br>~~es ~~<br>~~[a~~|DR06D03<br> ~~es~~<br>~~[a~~|DR06D06<br>~~es ~~|DR06D12<br> ~~ss~~|DR10D03<br>~~ss~~|DR10D06|DR10D10|DR10D12|DR10D24| Page 1 www.sensata.com Copyright © 2022 Sensata Technologies, Inc. ## **SPECIFICATIONS** ## Output[(1)] **==> picture [542 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> Description DR06D03 DR10D03 DR06D06 DR10D06 DR10D10 DR06D12 DR10D12 DR10D24<br>Operating Voltage [VDC] 1-60 1-100 1-60 1-60 1-100 1-60 1-60 1-100<br>Maximum Load Current [Adc] [(2)] 3 3 6 6 10 12 12 24<br>Minimum Load Current [mAdc] 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5<br>Maximum Off-State Leakage Current<br>0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1<br>@ Rated Voltage [mA]<br>Maximum On-State Voltage Drop @<br>0.6 0.6 0.6 0.6 0.2 0.6 0.6 0.2<br>Rated Current [Vpk]<br>Maximum Surge Current (10ms) [Apk] 60 60 60 60 80 100 100 160<br>On-State resistance at rated current<br>0.6 0.6 0.1 0.1 0.013 0.45 0.45 0.026<br>[Ohms]<br>Min/Max stranded wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG<br>Min/Max solid wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG<br>Weight (Typical) 1.76 oz 1.76 oz 1.94 oz 1.76 oz 1.76 oz 3.17 oz 3.17 oz 3.17 oz<br>(50 g) (50 g) (55 g) (50 g) (50 g) (90 g) (90 g) (90 g)<br>**----- End of picture text -----**<br> ## Input[(1)] **==> picture [542 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Control Voltage Range [(3)] 4-32 VDC<br>Minimum Turn-On Voltage 4.0 VDC<br>Must Turn-Off Voltage 1.0 VDC<br>Minimum Input Current for [mA] [(4)] 9<br>Maximum Input Current for [mA] [(4)] 11<br>Maximum Turn-on Time [msec] [(5)] 0.6<br>Maximum Turn-off Time [msec] 0.3<br>Min/Max stranded/solid wire 22/16 AWG<br>**----- End of picture text -----**<br> ## General[(2)] **==> picture [542 x 149] intentionally omitted <==** **----- Start of picture text -----**<br> Description Parameters<br>Dielectric Strength, Input/Output/Base 2500 Vrms<br>(50/60Hz)<br>Minimum Insulation Resistance (@ 500 V 10 [9] Ohms<br>DC)<br>Maximum Capacitance, Input/Output 10 pF<br>Ambient Operating Temperature Range -30 to 80 °C<br>Ambient Storage Temperature Range -30 to 100 °C<br>Recommended Terminal Screw Torque 4.4-7.0 lb-in (0.5-0.8 Nm)<br>Range<br>**----- End of picture text -----**<br> Page 2 www.sensata.com Copyright © 2022 Sensata Technologies, Inc. **MECHANICAL SPECIFICATIONS[(1)]** **==> picture [221 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> 3 A , 6 A & 10 A 12 A & 24 A<br>**----- End of picture text -----**<br> ## **EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS** ## **THERMAL DERATE INFORMATION** Page 3 www.sensata.com Copyright © 2022 Sensata Technologies, Inc. **==> picture [29 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> DR10D10<br>**----- End of picture text -----**<br> **==> picture [200 x 110] intentionally omitted <==** **==> picture [212 x 155] intentionally omitted <==** **==> picture [216 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> DR10D24<br>24<br>20<br>16<br>12<br>8<br>4<br>0<br>**----- End of picture text -----**<br> Single and multiple units (for DRxxx03) Single unit, distance to adjacent components ≥ 11 mm for DRxxx06, DR10D10 and ≥ 18 mm for DRxxx12, DR10D24 Multiple units, no minimum spacing between components ## **STANDARDS OF COMPLIANCE** ## **Shock and Vibration (Applies to all part numbers)** Vibration Resistance according to IEC 60068-2-6: **0.35mm and 0.75mm Amplitude over 10-55 Hz** Shock Resistance according to IEC 60068-2-27: **15g/11ms** ## **EMC (Applies to all part numbers)** IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ## **ANSI / ISA 12.12.01-2013** Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazardous (classified) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for Class I, Division 2 Page 4 www.sensata.com Copyright © 2022 Sensata Technologies, Inc. **ORDERING OPTIONS** Example : DR06D12 @ **DR 06 D 12** SSR Relay, DIN Rail Mount 18mm, 60VDC/12A,4-32VDC In, FET Output **Series DR Operating Voltage** ee **06:** 1-60 VDC **10:** 1-100 VDC **Control Voltage** — **D:** 4-32 VDC **Rated Load Current 03:** 3 Amps **06:** 6 Amps **10:** 10 Amps (100 VDC only) **12:** 12 Amps **24:** 24 Amps (100 VDC only) **ATEX Approvals Blank:** Not ATEX approved Required for valid part number ~~a~~ **X:** ATEX II 3G Ex nA IIC T4 Gc approved (3, 6 and 12 Amps only) For options only and not required for valid part number **GENERAL NOTES** ~~©~~ (1) All parameters at 25°C unless otherwise specified. - (2) See Derating curves - (3) DC control includes reverse polarity protection. (4) Input circuitry incorporates active current limiter. (5) Turn-on/off time for 10A is 0.5/0.3 msec & for 24A is 1/0.5 msec. **AGENCY APPROVALS & CERTIFICATIONS** © (3, 6 and 12 Amps only) Page 5 www.sensata.com Copyright © 2022 Sensata Technologies, Inc. **ACCESSORIES** ## **ID Marker Strips** ## **CNLB, CNLN, CNL2** **Black Strips Numbered 1 to 10 Strips Numbered 11 to 20 Strips** Part no.: CNLB Part no.: CNLN Part no.: CNL2 A package of 10 plastic strips comprising 10 A package of 10 plastic strips comprising 10 A package of 10 plastic strips comprising 10 individual unprinted markers which can be placed markers printed individually from 1 to 10 which markers printed individually from 11 to 20 which on sockets’ terminal block for easy identification can be placed on sockets’ terminal block for easy can be placed on sockets’ terminal block for easy during the use of multiple units. identification during the use of multiple units. identification during the use of multiple units. ## **WARNINGS** - RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE • The product’s side panels may be hot, allow the product to cool before touching • Follow proper mounting instructions including torque values • Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH • Disconnect all power before installing or working with this equipment • Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 6 Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements, and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED, OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY, AND SAFETY-ELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA www.sensata.com Rev:08/26/2022 ECN 21137 FDE-07-01 Rev. B Copyright © 2022 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →