Image not available
Illustrative purposes only
DR-4524
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 48 W, 24 VDC, 2 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC DIN Rail Mount Power Supplies
- No. of Outputs: 1 Output
- Output Power Max: 48W
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264VAC
- Input Voltage AC Min: 85VAC
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 2A
- Output Voltage - Output 1: 24VDC
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 30.74 € |
| Current stock | 10+ |
| Lead time | 30 days |
**- DR 45 series** ## MEAN WELL 45W Single Output Industrial DIN Rail Power Supply **- series** ~~a~~ ■ |**DR-4505**<br>**DR-4512**<br>**DR-4515**<br>**DR-4524**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>5A<br>3.5A<br>2.8A<br>2A<br>0 ~ 5A<br>0 ~3. 5A<br>0 ~ 2.8A<br>0 ~ 2A<br>25W<br>42W<br>42W<br>48W<br>100mVp-p<br>200mVp-p<br>240mVp-p<br>13.5 ~ 16.5V<br>480mVp-p<br>21.6 ~ 26.4V<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>10.8 ~ 13.2V<br>4.75 ~ 5.5V<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>800ms, 60ms/230VAC at full load<br>60ms/230VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>72%<br>77%<br>77%<br>80%<br>1.5A/115VAC 0.75A/230VAC<br>COLD START 28A/115VAC 56A/230VAC<br><1mA / 240VAC<br>105 ~ 150% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>5.75 ~ 6.75V<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>13.8 ~ 16.2V<br>17.25 ~ 20.25V<br>27.6 ~ 32.4V<br>Tj 135<br>typically (U1) detect on heat sink of power transistor<br>℃<br>Protection type : Shut down o/p voltage, re-power on to recover<br>-10 ~ +50<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>364.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>93*78*67mm (L*W*H)<br>0.31Kg; 48pcs/17.5Kg/1.3CUFT<br>℃<br>℃<br>℃<br>UL508, TUV EN60950-1,<br>approved<br>EAC TP TC 004<br>Compliance to EN55011,EN55032 (CISPR32), EN61000-3-2,-3, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A,EAC TP TC 020<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>N R N<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)|**DR-4505**<br>**DR-4512**<br>**DR-4515**<br>**DR-4524**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**WORKING TEMP.**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>5V<br>12V<br>15V<br>24V<br>5A<br>3.5A<br>2.8A<br>2A<br>0 ~ 5A<br>0 ~3. 5A<br>0 ~ 2.8A<br>0 ~ 2A<br>25W<br>42W<br>42W<br>48W<br>100mVp-p<br>200mVp-p<br>240mVp-p<br>13.5 ~ 16.5V<br>480mVp-p<br>21.6 ~ 26.4V<br>±2.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>10.8 ~ 13.2V<br>4.75 ~ 5.5V<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>±1.0%<br>800ms, 60ms/230VAC at full load<br>60ms/230VAC at full load<br>85 ~ 264VAC 120 ~ 370VDC<br>47 ~ 63Hz<br>72%<br>77%<br>77%<br>80%<br>1.5A/115VAC 0.75A/230VAC<br>COLD START 28A/115VAC 56A/230VAC<br><1mA / 240VAC<br>105 ~ 150% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br>5.75 ~ 6.75V<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>13.8 ~ 16.2V<br>17.25 ~ 20.25V<br>27.6 ~ 32.4V<br>Tj 135<br>typically (U1) detect on heat sink of power transistor<br>℃<br>Protection type : Shut down o/p voltage, re-power on to recover<br>-10 ~ +50<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-20 ~ +85<br>, 10 ~ 95% RH<br>℃<br>±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>364.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>93*78*67mm (L*W*H)<br>0.31Kg; 48pcs/17.5Kg/1.3CUFT<br>℃<br>℃<br>℃<br>UL508, TUV EN60950-1,<br>approved<br>EAC TP TC 004<br>Compliance to EN55011,EN55032 (CISPR32), EN61000-3-2,-3, EAC TP TC 020<br>Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A,EAC TP TC 020<br>**RIPPLE & NOISE (max.) Note.2**<br>**VOLTAGE TOLERANCE Note.3**<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SAFETY &**<br>**EMC**<br>**(Note 4)**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>N R N<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)|**DR-4505**|**DR-4512**|**DR-4515**|**DR-4524**| |---|---|---|---|---|---| ||**DC VOLTAGE**|5V|12V|15V|24V| ||**RATED CURRENT**|5A|3.5A|2.8A|2A| ||**CURRENT RANGE**|0 ~ 5A|0 ~3. 5A|0 ~ 2.8A|0 ~ 2A| ||**RATED POWER**|25W|42W|42W|48W| ||**RIPPLE & NOISE (max.) Note.2**|100mVp-p<br>N|200mVp-p<br>N|240mVp-p<br>|480mVp-p| ||**VOLTAGE ADJ. RANGE**|4.75 ~ 5.5V<br>N|10.8 ~ 13.2V<br>N|13.5 ~ 16.5V<br>|21.6 ~ 26.4V| ||**VOLTAGE TOLERANCE Note.3**|±2.0%<br>N|±1.0%<br>N|±1.0%<br>|±1.0%| ||**LINE REGULATION**|±1.0%<br>N|±1.0%<br>N|±1.0%<br>|±1.0%| ||**LOAD REGULATION**|±1.0%<br>N|±1.0%<br>N|±1.0%<br>|±1.0%| ||**SETUP, RISE TIME**|800ms, 60ms/230VAC at full load<br>N|||| ||**HOLD UP TIME (Typ.)**|60ms/230VAC at full load<br>N R|||| ||**VOLTAGE RANGE**|85 ~ 264VAC 120 ~ 370VDC<br> R|||| ||**FREQUENCY RANGE**|47 ~ 63Hz<br> R|||| ||**EFFICIENCY (Typ.)**|72%<br>|77%<br> R|77%<br>|80%| ||**AC CURRENT (Typ.)**|1.5A/115VAC 0.75A/230VAC<br>R|||| ||**INRUSH CURRENT (Typ.)**|COLD START 28A/115VAC 56A/230VAC<br>RN|||| ||**LEAKAGE CURRENT**|<1mA / 240VAC<br>R N|||| ||**OVERLOAD**|105 ~ 150% rated output power<br>Protection type :Constant current limiting, recovers automatically after fault condition is removed<br> N|||| ||**OVER VOLTAGE**|5.75 ~ 6.75V<br>Protection type : Shut off o/p voltage, clamping by zener diode<br>13.8 ~ 16.2V<br>17.25 ~ 20.25V<br>27.6 ~ 32.4V<br>N|||| ||**OVER TEMPERATURE**|Tj 135<br>typically (U1) detect on heat sink of power transistor<br>℃<br>Protection type : Shut down o/p voltage, re-power on to recover<br>N|||| ||**WORKING TEMP.**|-10 ~ +50<br>(Refer to "Derating Curve")<br>℃|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-20 ~ +85<br>, 10 ~ 95% RH<br>℃|||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃)<br>0.03%/<br>(0 ~ 50|||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6|||| ||**SAFETY STANDARDS**|UL508, TUV EN60950-1,<br>approved<br>EAC TP TC 004|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC|||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH|||| ||**EMC EMISSION**|Compliance to EN55011,EN55032 (CISPR32), EN61000-3-2,-3, EAC TP TC 020|||| ||**EMC IMMUNITY**|Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A,EAC TP TC 020|||| ||**MTBF**|364.6K hrs min. MIL-HDBK-217F (25<br>)<br>℃|||| ||**DIMENSION**|93*78*67mm (L*W*H)|||| ||**PACKING**|0.31Kg; 48pcs/17.5Kg/1.3CUFT|||| ||℃<br>℃<br>℃<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated load and 25 _ of ambient temperature.<br>2. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Tolerance: includes set up tolerance, line regulation and load regulation.<br>4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>5. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)||||| ## **SPECIFICATION** _File Name:DR-45-SPEC 2018-01-12_ **- DR 45 series** ## 45W Single Output Industrial DIN Rail Power Supply **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification Case No. 918A Unit:mm<br>46.5 46.5<br>9<br>8<br>7<br>6<br>5<br>4<br>3<br>Install DIN rail TS35/7.5 or TS35/15 2<br>1<br>Terminal Pin No. Assignment 77<br>Pin No. Assignment Pin No. Assignment 93<br>1 AC/L 6,7 DC OUTPUT+V<br>2 AC/N 8 LED<br>3 FG 9 +V ADJ.<br>4,5 DC OUTPUT -V<br>Block Diagram<br>fosc : 100KHz<br>EMI RECTIFIERS POWER RECTIFIERS +V<br>I/P & SWITCH- &<br>FILTER -V<br>FILTER ING FILTER<br>PWM<br>CONTROL DETECTION<br>FG CIRCUIT<br>Derating Curve Static Characteristics (24V)<br>Ta=25℃<br>32 350<br>100<br>28 300<br>80<br>24 250<br>60 20 200<br>16 150<br>40<br>12 100<br>20<br>8 50<br>-10 0 10 20 30 40 50 60 (VERTICAL) 70 80 100 120 140 160 180 200 220 240 260<br>AMBIENT TEMPERATURE ( ℃ ) INPUT VOLTAGE (V) 60Hz<br>NRND<br>LOAD (%) OUTPUT VOLTAGE (V) OUTPUT RIPPLE (mVp-p)<br>67<br>29<br>8.5<br>7.5<br>35 78<br>**----- End of picture text -----**<br> _File Name:DR-45-SPEC 2018-01-12_
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →