Image not available
Illustrative purposes only
DPU-3200-48CAN
AC/DC Enclosed Power Supply (PSU), CANBus Protocol, ITE & Industrial, 1 Outputs, 3.216 kW, 48 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: DPU-3200 Series
- No. of Outputs: 1Outputs
- Output Power Max: 3.216kW
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 67A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE & Industrial
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 652.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DPU - 3200 series** 3200W Power Supply with Single Output **==> picture [27 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> Front<br>|<br>Back<br>**----- End of picture text -----**<br> **==> picture [291 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> BauarSicherheitbeegelodwacmat geprufto ges g<br>www.ID 2000000000tuv.com<br>om) ED As UL62368-1 BS EN/EN62368-1 J TPTC004 A CBCEK IEC62368-1<br>■ Features<br>/<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> > ■ GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:DPU-3200-SPEC 2024-09-04_ > 3200W Power Supply with Single Output **DPU - 3200 series** seen errr reer rere ee eee ~~ee~~ ## **SPECIFICATION** |**DPU-3200-24**<br>**DPU-3200-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**Note.6**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC CURRENT (Typ.)**<br>**Note.5**<br>24V<br>48V<br>133A<br>67A<br>0 ~ 133A<br>0 ~ 67A<br>3192W<br>3216W<br>300mVp-p<br>23.5 ~ 30V<br>480mVp-p<br>47.5 ~ 58.8V<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>1500ms, 60ms/230VAC at full load<br>16ms / 230VAC at 75% load 9ms / 230VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>0.97/230VAC at full load<br>93.5%<br>COLD START 55A/230VAC<br>17A/230VAC<br><2mA / 230VAC<br>±0.5%<br>±0.5%<br>**VOLTAGE TOLERANCE**<br>**Note.4**<br>94.5%<br>**OVER TEMPERATURE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>105 ~ 115%rated current<br>Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover<br>31.5 ~ 37.5V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>63 ~ 75V<br>**PROTECTION**<br>Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage<br>Please refer to the Function Manual in following pages<br>**FUNCTION**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**ENVIRONMENT**<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>UL62368-1, CSA C22.2<br>, TUV<br>EN62368-1, EAC TP TC 004 approved<br>BS EN/<br>No. 62368-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>**ISOLATION RESISTANCE**<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>**OTHERS**<br>502.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 44.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>325.8*107*41mm (L*W*H)<br>**SAFETY &**<br>**EMC**<br>**(Note 10)**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>2.76Kg;4pcs/12Kg/0.81CUFT<br>**NOTE**<br>℃<br>https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual in following pages<br>**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>**CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2<br>**Standard**<br>**Standard**<br>BS EN/EN55032 (CISPR32)<br>BS EN/EN55032 (CISPR32)<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class A<br>Class A<br>-----<br>**ALARM SIGNAL**<br>**AUXILIARY POWER**<br>Isolated TTL signal output for T-Alarm and DC-OK. Please refer to the Function Manual in following pages<br>5V @ 0.3A, tolerance<br>10%, ripple 150mVp-p, 12V @ 0.8A, tolerance<br>10%, ripple 450mVp-p<br>±<br>±<br>**REMOTE SENSE**<br>**REMOTE ON OFF CONTROL**<br>**-**<br>Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual in following pages<br>By electrical signal or dry contact Power ON:<br>Function Manual<br>short Power OFF:open. Please refer to the<br>in following pages<br>**RIPPLE & NOISE (max.) Note.2,3**<br>~~————————~~<br>~~=>~~<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Under variable load application or parallel operation ripple of the output voltage may be higher than the SPEC at light load condition.<br>It will go back to normal<br>ripple level once the output load is more than 5%.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. The efficiency is measured at 75% load.<br>7. If use PV signal to adjust Vo, under certain operating conditions, ripple noise<br>of Vo might slightly go over rating defined in this specification.<br>8. Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover.<br>9. When 2 or more PSUs are in parallel connection, long cable(s) used for parallel connection might generate higher noise to communication signal. Thus, we<br>suggest using proper filtering part(s) to avoid interference on communication<br>.<br>10. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on<br>11. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**DPU-3200-24**<br>**DPU-3200-48**<br>**MODEL**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**Note.6**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**AC CURRENT (Typ.)**<br>**Note.5**<br>24V<br>48V<br>133A<br>67A<br>0 ~ 133A<br>0 ~ 67A<br>3192W<br>3216W<br>300mVp-p<br>23.5 ~ 30V<br>480mVp-p<br>47.5 ~ 58.8V<br>±1.0%<br>±1.0%<br>±0.5%<br>±0.5%<br>1500ms, 60ms/230VAC at full load<br>16ms / 230VAC at 75% load 9ms / 230VAC at full load<br>90 ~ 264VAC 127 ~ 370VDC<br>47 ~ 63Hz<br>0.97/230VAC at full load<br>93.5%<br>COLD START 55A/230VAC<br>17A/230VAC<br><2mA / 230VAC<br>±0.5%<br>±0.5%<br>**VOLTAGE TOLERANCE**<br>**Note.4**<br>94.5%<br>**OVER TEMPERATURE**<br>**OVERLOAD**<br>**OVER VOLTAGE**<br>105 ~ 115%rated current<br>Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover<br>31.5 ~ 37.5V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>Shut down o/p voltage, recovers automatically after temperature goes down<br>63 ~ 75V<br>**PROTECTION**<br>Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage<br>Please refer to the Function Manual in following pages<br>**FUNCTION**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>-30 ~ +70<br>(Refer to "Derating Curve")<br>℃<br>20 ~ 90% RH non-condensing<br>-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>**ENVIRONMENT**<br>10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes<br>**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>UL62368-1, CSA C22.2<br>, TUV<br>EN62368-1, EAC TP TC 004 approved<br>BS EN/<br>No. 62368-1<br>I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>**ISOLATION RESISTANCE**<br>**MTBF**<br>**DIMENSION**<br>**PACKING**<br>**OTHERS**<br>502.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 44.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>325.8*107*41mm (L*W*H)<br>**SAFETY &**<br>**EMC**<br>**(Note 10)**<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>2.76Kg;4pcs/12Kg/0.81CUFT<br>**NOTE**<br>℃<br>https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual in following pages<br>**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>**CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2<br>**Standard**<br>**Standard**<br>BS EN/EN55032 (CISPR32)<br>BS EN/EN55032 (CISPR32)<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>BS EN/EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>2KV/Line-Line 4KV/Line-Earth<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>Class B<br>Class A<br>Class A<br>-----<br>**ALARM SIGNAL**<br>**AUXILIARY POWER**<br>Isolated TTL signal output for T-Alarm and DC-OK. Please refer to the Function Manual in following pages<br>5V @ 0.3A, tolerance<br>10%, ripple 150mVp-p, 12V @ 0.8A, tolerance<br>10%, ripple 450mVp-p<br>±<br>±<br>**REMOTE SENSE**<br>**REMOTE ON OFF CONTROL**<br>**-**<br>Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual in following pages<br>By electrical signal or dry contact Power ON:<br>Function Manual<br>short Power OFF:open. Please refer to the<br>in following pages<br>**RIPPLE & NOISE (max.) Note.2,3**<br>~~————————~~<br>~~=>~~<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Under variable load application or parallel operation ripple of the output voltage may be higher than the SPEC at light load condition.<br>It will go back to normal<br>ripple level once the output load is more than 5%.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. The efficiency is measured at 75% load.<br>7. If use PV signal to adjust Vo, under certain operating conditions, ripple noise<br>of Vo might slightly go over rating defined in this specification.<br>8. Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover.<br>9. When 2 or more PSUs are in parallel connection, long cable(s) used for parallel connection might generate higher noise to communication signal. Thus, we<br>suggest using proper filtering part(s) to avoid interference on communication<br>.<br>10. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on<br>11. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to|**DPU-3200-24**|**DPU-3200-24**|**DPU-3200-48**|**DPU-3200-48**| |---|---|---|---|---|---| ||**DC VOLTAGE**|24V||48V|| ||**RATED CURRENT**|133A||67A|| ||**CURRENT RANGE**|0 ~ 133A||0 ~ 67A|| ||**RATED POWER**|3192W||3216W|| ||**RIPPLE & NOISE (max.) Note.2,3**|300mVp-p||480mVp-p|| ||**VOLTAGE ADJ. RANGE**|23.5 ~ 30V||47.5 ~ 58.8V|| ||**VOLTAGE TOLERANCE**<br>**Note.4**|±1.0%||±1.0%|| ||**LINE REGULATION**|±0.5%||±0.5%|| ||**LOAD REGULATION**|±0.5%||±0.5%|| ||**SETUP, RISE TIME**|1500ms, 60ms/230VAC at full load|||| ||**HOLD UP TIME (Typ.)**|16ms / 230VAC at 75% load 9ms / 230VAC at full load|||| ||**VOLTAGE RANGE**<br>**Note.5**|90 ~ 264VAC 127 ~ 370VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**POWER FACTOR (Typ.)**|0.97/230VAC at full load|||| ||**EFFICIENCY (Typ.)**<br>**Note.6**|93.5%||94.5%|| ||**AC CURRENT (Typ.)**<br>**Note.5**|17A/230VAC|||| ||**INRUSH CURRENT (Typ.)**|COLD START 55A/230VAC|||| ||**LEAKAGE CURRENT**<br>~~————————~~|<2mA / 230VAC<br>~~————————~~|||| ||**OVERLOAD**<br>~~————————~~|105 ~ 115%rated current<br>Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover<br>~~————————~~|||| ||**OVER VOLTAGE**<br>~~————————~~|31.5 ~ 37.5V<br>Protection type : Shut down o/p voltage, re-power on to recover<br>63 ~ 75V<br>~~————————~~|||| ||**OVER TEMPERATURE**<br>~~————————~~|Shut down o/p voltage, recovers automatically after temperature goes down<br>~~————————~~|||| ||**OUTPUT VOLTAGE PROGRAMMABLE(PV)**<br>~~————————~~|Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage<br>Please refer to the Function Manual in following pages<br>~~————————~~|||| ||**CONSTANT CURRENT LEVEL PROGRAMMABLE(PC)**|Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual in following pages|||| ||**REMOTE ON OFF CONTROL**<br>**-**|By electrical signal or dry contact Power ON:<br>Function Manual<br>short Power OFF:open. Please refer to the<br>in following pages|||| ||**REMOTE SENSE**|Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual in following pages|||| ||**AUXILIARY POWER**|5V @ 0.3A, tolerance<br>10%, ripple 150mVp-p, 12V @ 0.8A, tolerance<br>10%, ripple 450mVp-p<br>±<br>±|||| ||**ALARM SIGNAL**|Isolated TTL signal output for T-Alarm and DC-OK. Please refer to the Function Manual in following pages|||| ||**WORKING TEMP.**|-30 ~ +70<br>(Refer to "Derating Curve")<br>℃|||| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +85<br>, 10 ~ 95% RH non-condensing<br>℃|||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|||| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS**<br>~~=>~~|UL62368-1, CSA C22.2<br>, TUV<br>EN62368-1, EAC TP TC 004 approved<br>BS EN/<br>No. 62368-1<br>~~=>~~|||| ||**WITHSTAND VOLTAGE**<br>~~=>~~|I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>~~=>~~|||| ||**ISOLATION RESISTANCE**<br>~~=>~~|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~=>~~|||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~=>~~|**Parameter**<br>~~=>~~|**Standard**<br>~~=>~~||**Test Level / Note**<br>~~=>~~| |||Conducted<br>~~=>~~|BS EN/EN55032 (CISPR32)<br>~~=>~~||Class B<br>~~=>~~| |||Radiated<br>~~=>~~|BS EN/EN55032 (CISPR32)<br>~~=>~~||Class A<br>~~=>~~| |||Harmonic Current<br>~~=>~~|BS EN/EN61000-3-2<br>~~=>~~||Class A<br>~~=>~~| |||Voltage Flicker<br>~~=>~~|BS EN/EN61000-3-3<br>~~=>~~||-----<br>~~=>~~| |||BS EN/<br>BS EN/<br>EN55035,<br>EN61000-6-2<br>~~=>~~|||| |||**Parameter**<br>~~=>~~|**Standard**<br>~~=>~~||**Test Level / Note**<br>~~=>~~| |||ESD<br>~~=>~~|BS EN/EN61000-4-2<br>~~=>~~||Level 3, 8KV air ; Level 2, 4KV contact<br>~~=>~~| |||Radiated<br>~~=>~~|BS EN/EN61000-4-3<br>~~=>~~||Level 3<br>~~=>~~| |||EFT / Burst<br>~~=>~~|BS EN/EN61000-4-4<br>~~=>~~||Level 3<br>~~=>~~| |||Surge<br>~~=>~~|BS EN/EN61000-4-5<br>~~=>~~||2KV/Line-Line 4KV/Line-Earth<br>~~=>~~| |||Conducted<br>~~=>~~|BS EN/EN61000-4-6<br>~~=>~~||Level 3<br>~~=>~~| |||Magnetic Field<br>~~=>~~|BS EN/EN61000-4-8<br>~~=>~~||Level 4<br>~~=>~~| |||Voltage Dips and Interruptions<br>~~=>~~|BS EN/EN61000-4-11<br>~~=>~~||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>~~=>~~| |||502.9K hrs min.<br>Telcordia SR-332 (Bellcore) ; 44.9K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~=>~~|||| ||**DIMENSION**|325.8*107*41mm (L*W*H)|||| ||**PACKING**<br>2.76Kg;4pcs/12Kg/0.81CUFT<br>℃<br>https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>℃<br>℃<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>3. Under variable load application or parallel operation ripple of the output voltage may be higher than the SPEC at light load condition.<br>It will go back to normal<br>ripple level once the output load is more than 5%.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Derating may be needed under low input voltages. Please check the derating curve for more details.<br>6. The efficiency is measured at 75% load.<br>7. If use PV signal to adjust Vo, under certain operating conditions, ripple noise<br>of Vo might slightly go over rating defined in this specification.<br>8. Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover.<br>9. When 2 or more PSUs are in parallel connection, long cable(s) used for parallel connection might generate higher noise to communication signal. Thus, we<br>suggest using proper filtering part(s) to avoid interference on communication<br>.<br>10. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on<br>a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to<br>perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on<br>11. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>Product Liability Disclaimer<br>For detailed information, please refer to||||| (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 11. The ambient temperature derating of 3.5 ℃ /1000m with fanless models and of 5 ℃ /1000m with fan models for operating ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:DPU-3200-SPEC 2024-09-04_ **DPU - 3200 series** ## 3200W Power Supply with Single Output ## **BLOCK DIAGRAM** **==> picture [533 x 605] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 110KHz<br>PWM fosc : 90KHz<br>+S<br>I/P FILTEREMI CURRENTLIMITINGINRUSHACTIVE RECTIFIERSPFC& SWITCHINGPOWER RECTIFIERSFILTER& ORINGFET -V+V<br>DETECTION -S<br>CIRCUIT ORING FET<br>CONTROL<br>O.V.P.<br>DETECTION PV/PC<br>CIRCUIT MCU O.T.P.<br>TRANSCEIVERS DA/DB<br>O.T.P. MCU DATA T-Alarm<br>ISOLATION DC-OK<br>FAN (SDA/SCL)<br>AUX (CANH/CANL)<br>POWER AUX. POWER<br>RECTIFIERS<br>& 5V/0.3A Remote ON-OFF<br>FILTER 12V/0.8A<br>STATIC CHARACTERISTICS DERATING LOADs vs INPUT VOLTAGE<br>MODEL<br>100 INPUT 24V 48V<br>90 3192W 3216W<br>180~264VAC<br>80 133A 67A<br>70 90VAC 1596W 1608W<br>66.5A 33.5A<br>60<br>50<br>40<br>30<br>90 100 115 180 264<br>INPUT VOLTAGE (VAC) 60Hz<br>DERATING CURVE EFFICIENCY vs LOAD (48V MODEL)<br>96<br>100 94<br>80 92<br>230VAC<br>Input only<br>60 90<br>50<br>40 88<br>86<br>20<br>84<br>-30 -25 -10 0 15 30 50 60 70 (HORIZONTAL) 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>AMBIENT TEMPERATURE ( ℃ )<br>LOAD<br>◎ The curve above is measured at 230VAC.<br>LOAD (%)<br>EFFICIENCY (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:DPU-3200-SPEC 2024-09-04_ **DPU - 3200 series** ## 3200W Power Supply with Single Output ## **FUNCTION MANUAL** **1. Voltage Drop Compensation** **==> picture [439 x 146] intentionally omitted <==** **----- Start of picture text -----**<br> 1.1 Remote Sense<br>※ The Remote Sense compensates voltage drop on the load wiring up to 0.5V<br>+V<br>PIN15 +S<br>LOAD<br>PIN16 -S<br>-V<br>-V CN1 +V<br>Sense lines should be twisted in pairs to minimize noise pick-up.<br>◎ The +S signal should be connected to the positive terminal of the load whereas -S signal to the negative terminal.<br>**----- End of picture text -----**<br> - 1.2 Local Sense **==> picture [490 x 465] intentionally omitted <==** **----- Start of picture text -----**<br> ※ The +S,-S have to be connected to the +V(signal), -V(signal), respectively, as the following diagram, in order to get the correct output voltage if<br>Remote Sense is not used.<br>+V<br>PIN13 +V(signal) LOAD<br>PIN15 +S<br>-V<br>PIN14 -V(signal)<br>PIN16 -S<br>-V CN1 +V<br>2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)<br>※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 50~125% of the nominal voltage by applying<br>EXTERNAL VOLTAGE.<br>PIN12 PV PIN14 -V(signal)<br>-V CN1 +V<br>EXTERNAL VOLTAGE (DC)<br>◎ For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section.<br>Vout<br>100<br>125<br>80<br>100<br>60<br>40<br>50<br>20<br>V<br>50 90 95 100 125<br>V<br>0 0.4 1 4.7 5 OUTPUT VOLTAGE (%)<br>◎ The rated current should change with the Output Voltage Programming accordingly.<br>EXTERNAL VOLTAGE (DC)<br>◎ For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section.<br>OUTPUT VOLTAGE(%) OUTPUT CURRENT (%)<br>**----- End of picture text -----**<br> _File Name:DPU-3200-SPEC 2024-09-04_ **DPU - 3200 series** 3200W Power Supply with Single Output ## **3. Constant Current Level Programming (or, PC / remote current programming / dynamic current trim)** ※ The constant current level can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE. **==> picture [475 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> Iout<br>110<br>100<br>Non-Linear<br>PIN11 PC PIN14 -V(signal)<br>-V CN1 +V<br>EXTERNAL VOLTAGE (DC)<br>◎ For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section. 20<br>◎ Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover.<br>V<br>※ If setting output current to a much lower level, as output status turns to constant current 0.4 1 4.7 5<br>mode, it might cause higher current ripple under such condition. EXTERNAL VOLTAGE (VDC)<br>OUTPUT CURRENT (%)<br>**----- End of picture text -----**<br> ## **4. Remote ON-OFF Control** - ※ The power supply can be turned ON/OFF individually or along with other units by using the "Remote ON-OFF" function. **==> picture [419 x 56] intentionally omitted <==** **----- Start of picture text -----**<br> PIN3 +5V-AUX switch Between Remote ON-OFF and +5V-AUX Power Supply Status<br>Switch Short ON<br>Switch Open OFF<br>PIN4 Remote ON-OFF<br>-V CN1 +V<br>**----- End of picture text -----**<br> ## **5. Alarm Signal Output** - ※ There are 2 alarm signals, DC OK and T-ALARM, in TTL signal form, on CN1. These signals are isolated from output. The maximum sink current is 10mA. **==> picture [291 x 60] intentionally omitted <==** **----- Start of picture text -----**<br> PIN5 DC OK<br>Application<br>Circuit<br>PIN6 T-ALARM<br>-V CN1 +V PIN2 GND-AUX<br>**----- End of picture text -----**<br> _File Name:DPU-3200-SPEC 2024-09-04_ **DPU - 3200 series** ## 3200W Power Supply with Single Output - **6.Current Sharing with Remote Sense** DPU-3200 has the built-in active current sharing function and can be connected in parallel, up to 5 units, to provide higher output power as exhibited below : ※ The power supplies should be paralleled using short and large diameter wiring and then connected to the load. ※ Difference of output voltages among parallel units should be less than 0.2V. - ※ The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(Rated current per unit)×(Number of unit)×0.9 - ※ When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit)×(Number of unit) the current shared among units may not be balanced. - ※ Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 5%. - ※ CN500/SW1 Function pin connection **==> picture [470 x 475] intentionally omitted <==** **----- Start of picture text -----**<br> PSU1 PSU2 PSU3 PSU4 PSU5<br>Parallel<br>CN500 SW1 CN500 SW1 CN500 SW1 CN500 SW1 CN500 SW1<br>1 unit X ON<br>2 unit V ON V ON<br>3 unit V ON V OFF V ON<br>4 unit V ON V OFF V OFF V ON<br>5 unit V ON V OFF V OFF V OFF V ON<br>(V : CN500 connected ; X : CN500 not connected.)<br>DPU-3200 DPU-3200 DPU-3200 DPU-3200 DPU-3200<br>PSU1 PSU2 PSU3 PSU4 PSU5<br>-V -V -V -V -V<br>+V TB1 +V TB1 +V TB1 +V TB1 +V TB1<br>-V +V<br>Twisted wires LOAD<br>Fig 5.1<br>6 4 2 6 4 2 6 4 2 6 4 2 6 4 2<br>-V(signal) DB DA -V(signal) DB DA -V(signal) DB DA -V(signal) DB DA -V(signal) DB DA<br>-V(signal) DB DA -V(signal) DB DA -V(signal) DB DA -V(signal) DB DA -V(signal) DB DA<br>5 3 1 5 3 1 5 3 1 5 3 1 5 3 1<br>PSU1 CN500 PSU5 CN500<br>PSU2 CN500 PSU3 CN500 PSU4 CN500<br>If the lines of CN500 are too long, they should<br>be twisted in pairs to avoid the noise.<br>◎ DA,DB and -V(signal) are connected mutually in parallel.<br>◎ For Remote Sense / Local Sense, please refer to “Voltage Drop Compensation” section.<br>∣ ∣ ∣ ∣ ∣ ∣ ∣ ∣<br>∣ ∣ ∣ ∣ ∣ ∣<br>∣ ∣ ∣ ∣<br>∣ ∣<br>**----- End of picture text -----**<br> _File Name:DPU-3200-SPEC 2024-09-04_ **DPU - 3200 series** 3200W Power Supply with Single Output ## **MECHANICAL SPECIFICATION** **==> picture [482 x 736] intentionally omitted <==** **----- Start of picture text -----**<br> (Unit: mm , tolerance ±0.5mm) Case No.256<br>30 6.25 276<br>2-ψ2.8<br>2-M4 L=5<br>21<br>2 2<br>276 43.5<br>28<br>-V<br>38<br>Air flow<br>+V direction<br>SVR (TOP View)<br>LED SW1<br>1<br>2 I/P<br>3<br>6 17<br>2 2<br>2-M4 L=5<br>2-ψ2.8<br>12 max.<br>6.25 276<br>325.8<br>1<br>1<br>(Bottom View)<br>3-M3 L=4<br>1<br>16 46 241.5<br>Chassis of DPU-3200<br>※ Mounting Instruction Mounting Surface<br>Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque<br>1 M3 4mm 6~8Kgf-cm<br>2 M4 5mm 7~1 K0 gf-cm<br>Mounting Screw<br>※ Control Pin No. Assignment(CN1) : HRS DF11-16DP-2DS or equivalent<br>1 15<br>Mating Housing HRS DF11-16DS or equivalent<br>Terminal HRS DF11-**SC or equivalent<br>2 16<br>Pin No. Function Description<br>1 +12V-AUX Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX (pin2).<br>The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by “Remote ON-OFF”.<br>2 GND-AUX Auxiliary voltage output GND.<br>The signal return is isolated from the output terminals (+V & -V).<br>3 +5V-AUX Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin2).<br>The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by “Remote ON-OFF<br>4 Remote The unit can turn the output ON/OFF by electrical signal or dry contact between Remote ON/OFF and +5V-AUX . (Note.2)<br>ON-OFF Short (4.5 ~ 5.5V) : Power ON ; Open (-0.5 ~ 0.5V) : Power OFF ; The maximum input voltage is 5.5V.<br>High (3.5 ~ 5.5V) : When the Vout ≦77%±5%.<br>5 DC-OK Low (-0.5 ~ 0.5V) : When Vout ≧80%±5%.<br>The maximum sourcing current is 10mA and only for output. (Note.2)<br>High (3.5 ~ 5.5V) : When the internal temperature exceeds the limit of temperature alarm, or when Fan fails.<br>6 T-ALARM Low (-0.5 ~ 0.5V) : When the internal temperature is normal, and when Fan works normally.<br>The maximum sourcing current is 10mA and only for output(Note.2)<br>NC For standard model: Retain for future use.<br>7,8,9<br>A0,A1,A2 For PMBus / CANBus model: PMBus / CANBus interface address lines. (Note.1)<br>10 NC Retain for future use.<br>11 PC Connection for constant current level programming. (Note.1)<br>12 PV Connection for output voltage programming. (Note.1)<br>13 +V (Signal) Positive output voltage signal.<br>It is for local sense; it cannot be connected directly to the load.<br>14 -V (Signal) Negative output voltage signal.<br>It is for local sense and certain function reference; it cannot be connected directly to the load.<br>15 +S Positive sensing for remote sense.<br>16 -S Negative sensing for remote sense.<br>Note1: Non-isolated signal, referenced to [-V(signal)].<br>Note2: Isolated signal, referenced to GND-AUX.<br>ψ<br>6.5<br>9<br>29.6 21.6 16.8 22.8<br>107<br>10<br>13 41<br>16.8 22.8<br>2<br>127 137<br>15 4<br>97.9<br>53.5<br>6.9<br>2 1<br>CN1 6 1 5 1<br>8 2<br>CN500 7 1<br>**----- End of picture text -----**<br> _File Name:DPU-3200-SPEC 2024-09-04_ **DPU - 3200 series** ## 3200W Power Supply with Single Output ||※|※|LED Status Indicators|LED Status Indicators|LED Status Indicators|LED Status Indicators|LED Status Indicators|LED Status Indicators|LED Status Indicators|LED Status Indicators||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||LED||||Description||||| |||||||Green||||The power supply functions normally.||||| |||||||Red||||The LED will present a constant red light when the abnormal status (OTP, OLP, fan fail) arises.||||| |||||||Red (Flashing)||||The LED will flash with the red light when the internal temperature reaches 60<br>; under this condition, the unit still operates normally<br>℃<br>without entering OTP. In the meantime, an alarm signal will be sent out through the PMBus interface.)<br>(||||| ||※||AC Input Terminal Pin No. Assignment|||||||||||| |||Pin No.||||Assignment||||Diagram<br>Maximum mounting torque||||| ||||1|||FG||||1<br>2<br>3||||| ||||3<br>2|||AC/N<br>AC/L||||8Kgf-cm||||| |※Control Pin No.|||||||Assignment(<br>) : HRS DF11-8DP-2DS or equivalent<br>CN500|||||||| |||8||2||||||Mating Housing<br>HRS DF11-8DS or equivalent||||| |||||||||||Terminal<br>HRS DF11-**SC or equivalent||||| |||7||1||||||||||| |||||||||||||||| |||**Pin No.**||||**Function**||||**Description**||||| ||||1,|2||DA||||Differential digital signal for parallel control.||||| ||||3,|4||DB||||Differential digital signal for parallel control.||||| ||||5,|6||-V (Signal)||||Negative output voltage signal.<br>It is for local sense and certain function reference; it cannot be connected|||directly to the load.|| |||||||NC||||For standard model: None.||||| ||||7|||SDA||||For PMBus model: Serial Data used in the PMBus interface. (Note)||||| |||||||CANH||||For CANBus model: Data line used in CANBus interface. (Note)||||| |||||||NC||||For standard model: None.||||| ||||8|||SCL||||For PMBus model: Serial Clock used in the PMBus interface. (Note)||||| |||||||CANL||||For CANBus model: Data line used in CANBus interface. (Note)||||| |Note: Isolated signal, referenced to GND-AUX.||||||||||||||| |※Control Pin No.|||||||Assignment.(SW1)|||||||| |||**Pin No.**||||**Function**||||**Description**||||| ||||1,|2||Terminal<br>resistance||||SW1 is the selector of terminal resistor that is designed for DA/DB|signals and parallel control function.|||| ## **INSTALLATION MANUAL** Please refer to : http://www.meanwell.com/manual.html _File Name:DPU-3200-SPEC 2024-09-04_
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →