- Manufacturer: LASCAR
- Product type: Digital Panel Meters
- No. of Digits / Alpha:3-1/2; Meter Function:AC Voltage; Meter Range:0V to 500V; Digit Height:19mm; Panel Cutout Height:40mm; Panel Cutout Width:72mm; Supply Voltage Min:7.5V; Supply Voltag
- SVHC: No SVHC (07-Nov-2024)
- Meter Range: 0V to 500V
- Digit Height: 19mm
- Product Range: -
- Meter Function: AC Volts
- Panel Cutout Width: 72mm
- Supply Voltage Max: 14V
- Supply Voltage Min: 7.5V
- Panel Cutout Height: 40mm
- No. of Digits / Alpha: 3.5
- Operating Temperature Max: 50°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 83.12 € |
| Current stock | 10+ |
| Lead time | 30 days |
Digital AC Voltmeter Module
## DPM 970
A 3 ½ digit LCD panel meter, featuring 19mm (0.75“) digit height and LED backlighting, the DPM 970 is a true RMS voltage and current meter with 500V a.c. (2kV O 2 ) and 2mA full scale readings as standard. By changing the value of scaling resistors or adding a shunt, this module will measure most a.c. voltages and currents. The DPM 970 features digital hold function which freezes the last displayed reading. Calibration is achieved via two multi-turn potentiometers for offset and scale. Connection to the meter is via screw terminals. The module is housed in a robust carrier which can be bolted in place or panel mounted using the bezel, window and clips provided.
## **19mm (0.75“) Digit Height**
**Screw Terminal Connections**
- e **Digital Hold** @ **500V a.c. (2kV** O 2 **) Full Scale Reading** @ **Measures Voltage and Current**
## **LED Backlighting**
## **SCALING**
To change the full scale reading (F.S.R) of the meter, use the resistor values and PL10 configuration as detailed in the table below. To ensure that the meter reads "000" with zero input voltage/current, short circuit ACV and COM and adjust the ZERO potentiometer. The meter will need recalibration by adjusting the CAL potentiometer.
Option 1 = Make PL10 pins 2 & 3
Option 2 = Make PL10 pins 1 & 2
|**NOTES**<br>1<br>Use inputs ACV and COM for measuring voltage.<br>For measuring voltages above 500V<br>, external scaling resistor must be used.<br>2<br>200mV<br>0R<br>0R<br>Not Fitted<br>Option 1<br>2V<br>390k<br>220k<br>330k<br>Option 2<br>20V<br>680k<br>390k<br>39k<br>Option 2<br>200V<br>560k<br>560k<br>3k9<br>Option 2<br>2kV(factorydefault)<br>560k<br>560k<br>390R<br>Option 2<br>2mA<br>-<br>-<br>100R<br>Option 1<br>20mA<br>-<br>-<br>10R<br>Option 1<br>200mA<br>-<br>-<br>1R<br>Option 1<br>2A<br>-<br>-<br>0R1<br>Option 1<br>20A<br>-<br>-<br>0R01<br>Option 1<br>**Required F.S.R**<br>**RA1**<br>**RA2**<br>**RB1**<br>**PL10**<br>~~———— ~~<br>~~SE —~~<br>~~en~~<br>~~es~~<br>~~oof~~<br>~~JT~~<br>~~YTTf~~<br>~~pe~~<br>~~a~~<br>~~oo~~<br>~~a~~<br>~~ss~~<br>~~Gs~~<br>~~es~~<br>~~$$~~<br>——<br>5|
|---|
|Use inputs ACI and COM for measuring current.<br>When measuring in excess of 200mA use an external scaling resistor fitted<br>Between the terminals of ACI and COM. We recommend the use of a current<br>3<br>4<br>O|
|transformer when measuring in excess of 10 Amps.|
Consult the current transformer manufacturer’s data for connections and recommendations. Other scaling factors can be achieved via the correct selection of scaling resistor values.
|**Specification**<br>~~ee~~|**Min.**<br>~~ee~~|**Typ.**<br>~~ee~~|**Max.**<br>~~ee~~|**Unit**<br>~~ee~~|
|---|---|---|---|---|
|Accuracy (overall error)*<br>~~ee~~<br>~~pO~~<br>|~~ee~~<br><br>~~ES~~|0.5<br>~~ee~~<br><br>~~ES~~|1.5<br>~~ee~~<br>|%(±2 count)<br>~~ee~~<br>|
|Full scale reading**<br>Resolution<br>~~ee ~~<br>~~pO~~<br>~~eS~~<br>~~A~~|0<br> ~~ee ~~<br>~~eS~~<br>~~ES~~<br>~~A~~|~~ee ~~<br>~~eS~~<br>~~ES~~<br>~~A~~|1999<br> ~~ee~~<br>~~eS~~|V<br>RMS<br>~~ee~~<br>~~eS~~|
|Resolution<br>~~pO~~<br><br>~~A~~<br>~~**eS**~~|~~ES~~<br>~~A~~<br>~~**eS**~~<br>~~SS A~~|1<br><br>~~ES~~<br>~~A~~<br>~~**eS**~~<br>~~A~~|~~**eS**~~<br>~~ES~~|V<br>RMS<br><br>~~**eS**~~|
|Sample rate<br>~~A~~<br>~~**eS**~~|~~ES ~~<br>~~A~~<br>~~**eS**~~<br>~~SS A~~<br>~~SS~~|3<br> ~~ES~~<br>~~A~~<br>~~**eS**~~<br>~~A~~<br>~~A~~|~~**eS**~~<br>~~ES~~<br>~~ES~~|samples/sec<br>~~**eS**~~|
|Operatingtemperature range<br>~~**eS**~~<br>~~**eS** A~~|0<br>~~**eS**~~<br>~~SS A~~<br>~~SS~~<br>~~A~~|~~**eS**~~<br>~~A~~<br>~~A~~<br>~~A~~|50<br>~~**eS**~~<br>~~ES~~<br>~~ES~~<br>~~A~~|°C<br>~~**eS**~~|
|Temperature s<br>tability<br>~~**eS** A~~|~~SS~~<br>~~A~~<br>~~SS~~|200<br>~~A~~<br>~~A~~<br>~~SS~~|~~ES~~<br>~~A~~<br>~~SS~~|ppm/°C|
|Frequencyrange (input voltage)<br>~~**eS** A~~<br>~~a~~|15<br>~~SS~~<br>~~A~~<br>~~SS~~<br>~~a~~|~~A~~<br>~~A~~<br>~~SS~~<br>~~a~~|15k<br>~~ES~~<br>~~A~~<br>~~SS~~<br>~~a~~|Hz<br>~~a~~|
|Input impedance(2kV range)<br>~~**eS** A~~<br>~~a~~<br>~~eS~~|~~A ~~<br>~~SS~~<br>~~a~~<br>~~eS~~<br>~~A~~|1<br> ~~A ~~<br>~~SS~~<br>~~a~~<br>~~eS~~<br>~~A~~|~~A~~<br>~~SS~~<br>~~a~~<br>~~eS~~<br>~~A~~|M<br>~~a~~<br>~~eS~~|
|DC Supplyvoltage<br>~~a~~<br>~~eS~~|7.5<br>~~a~~<br>~~eS~~<br>~~A~~|9<br>~~a~~<br>~~eS~~<br>~~A~~<br>~~A~~|14<br>~~a~~<br>~~eS~~<br>~~A~~<br>~~ES~~|V d.c.<br>~~a~~<br>~~eS~~|
|Supplycurrent (Backlightingoff)<br>~~SE~~|~~A~~<br>~~SE~~|1.5<br>~~A~~<br>~~SE~~<br>~~A~~|~~A~~<br>~~SE~~<br>~~ES~~|mA d.c.<br>~~SE~~|
|Supply current (Backlighting on)<br>@ 5Vd.c.<br>~~SE~~|~~SE~~|50<br>~~SE~~<br>~~A~~|~~SE~~<br>~~ES~~|mA d.c.<br>~~SE~~|
- To ensure maximum accuracy, re-calibrate periodically.
** Maximum safe input voltage across the ACV and COM terminals is 500VRMS. If voltages to be measured exceed 500VRMS, then fit scaling resistors externally to the module.
**==> picture [524 x 261] intentionally omitted <==**
**----- Start of picture text -----**<br>
DIMENSIONS All dimensions in mm (inches) PanelMaximumcut-outpanel72 thicknessx 40 (2.833mmx 1.57)(0.12).<br>76.0 (2.99)<br>a<br>72.5 (2.85)<br>— { e \| -<br>51 (2.01)<br>a. 1.0 (0.04)<br>b. 2.0 (0.08) Display in Test Mode<br>c. 6.5 (0.26)<br>d. 11.5 (0.45)<br>51.0 (2.01) a e. 12.5 (0.49)*<br>b c *typical depth of tallest component behind PCB,<br>this dimension is for guidance only.<br>61.5 (2.42)<br>51.0 (2.01) Ø5.7 d e<br>| | _ rr Beat GEESE<br>(0.22)<br>| ® LASCAR bina! CAL<br>& [| @ | ®“a : =<br>71.5 (2.81) Ø3.0<br>7 | | (0.12) ae ac Core a #<br>Specifications liable to change without prior warning DPM 970 Issue 12 06/2010 S.L. Applies to DPM 970/12<br>(0.94)<br>24<br>(1.73) (1.59) (0.94)<br>44.0 40.5 24.0<br>(1.54) (0.94) (0.96)<br>39.0 24.0 24.5<br>**----- End of picture text -----**<br>
_**Specifications liable to change without prior warning**_
**www.lascarelectronics.com**
**LASCAR ELECTRONICS LTD. MODULE HOUSE, WHITEPARISH, LASCAR ELECTRONICS INC. LASCAR ELECTRONICS (HK) LTD. WILTSHIRE SP5 2SJ 4258 WEST 12th STREET, 8th FLOOR, CHINA AEROSPACE CENTRE, 143 HOI BUN UK ERIE, PA 16505 USA ROAD, KWUN TONG, KOWLOON, HONG KONG TEL: +44 (0)1794 884567 FAX: +44 (0)1794 884616 TEL: +1 (814) 835 0621 FAX: +1 (814) 838 8141 TEL: +852 2389 6502 FAX: +852 2389 6535 E-mail: sales@lascar.co.uk E-mail: us-sales@lascarelectronics.com E-mail: saleshk@lascar.com.hk**
## **SCREW TERMINAL FUNCTIONS**
ACV Alternating voltage measurement input, accepts up to 500V a.c. By changing the values of scaling resistors RA1, RA2 and RB1, other voltage and current ranges can be achieved. To measure in excess of 500V a.c., remove RA1, RA2 and RB1 from the meter and fit an external divider that will output 700mV for a 2kV input, e.g. series resistor 1.12 M shunt resistor 390R, link RA1 and RA2 on the meter. See scaling table for suitable values for RA1, RA2 and RB1.
- ACI Alternating current measurement input.
- See Scaling table for suitable values for shunt resistor RB1.
- COM Return line for voltage measurement input (ACV) or current measurement (ACI) input.
- COM Return line for voltage measurement input (ACV) or current measurement (ACI) input. V+ Positive power supply input.
- V- Negative power supply input.
- LPNegative supply for LED backlighting.
- LP+ Positive supply for LED backlighting.
- TST Connect to V+ to display all segments except decimal points and annunciators. It should not be operated for more than a few seconds as the DC voltage applied to the LCD may “burn” the display. This connection is normally at 5V below V+ and is the ground for the digital section of the meter.
- HLD Digital Hold option. Connect to V+ to hold last displayed reading indefinitely.
- ALM Alarm “!” annunciator. Connect to XDP to display.
- XDP Annunciator drive waveform. Used to drive alarm annunciator (ALM) if required.
V+ Auxilliary V+ for connections to decimal points DP1, DP2 or DP3. DP1 199.9 Connect to V+ to display required decimal point. DP2 19.99 Connect to V+ to display required decimal point. DP3 1.999 Connect to V+ to display required decimal point.
**==> picture [539 x 436] intentionally omitted <==**
**----- Start of picture text -----**<br>
SAFETY WARNING<br>To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s connectors must not exceed 500VRMS. If voltages to be measured exceed<br>500VRMS, then fit scaling resistors externally to the module. If the mains power supply is connected to the module, then all the module’s connectors must be<br>considered to be floating at mains potential. Consequently due caution must be exercised when connecting to the module’s connector functions under these<br>conditions. The user must ensure that the incorporation of the DPM into the user’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements<br>for Electrical Equipment for Measuring, Control and Laboratory Use).<br>APPLICATIONS Phase<br>LP+ V+ +5V 110/240V<br>WARNING : Do not apply in excess of 500V a.c. to the meter. V- COM-5V PSU 303<br>LP- 0V<br>Neutral<br>Phase 1 ACV Voltage V+ Powering the LED backlighting on a DPM 970<br>COM from the PSU 303's +5V and COM outputs.<br>V-<br>SE Load ACI Current : V+ +-5V5V PSU 303110/240V<br>COM<br>V- 0V Phase ACV Voltage V+<br>COM<br>Phase 2 _ =r COMACV Voltage V+V- Load =a ACI Current V+V- +5V-5V PSU 303110/240V<br>Load ACI Current V+ +-55VV PSU 303110/240V Neutral ~~ — COM V- _ 0V<br>COM = V- 0V Single Phase Current and Voltage<br>Measurement<br>Phase 3 ACV Voltage V+<br>COM<br>V-<br>Load ACI Current V+ +-5V5V PSU 303110/240V Phase Load CT ACI V+V- +-5V5V _ PSU 303110/240V<br>ot COM 1999 V- 0V Neutral COM 0V<br>Neutral o. =<br>—_<br>3-Phase Current and Voltage Using a current transformer (CT) to<br>Measurement measure currents in excess of 10A a.c.<br>Specifications liable to change without prior warning DPM 970 Issue 12 06/2010 S.L. Applies to DPM 970/12<br>**----- End of picture text -----**<br>
_**Specifications liable to change without prior warning**_
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →