DNR30US12
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 30 W, 12 VDC, 2.5 A
- Manufacturer: XP POWER
- Product type:
- No. of Outputs:1 Output; Output Power Max:30W; Output Voltage - Output 1:12VDC; Output Current - Output 1:2.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Vol
- SVHC: No SVHC (16-Jul-2019)
- Product Range: DNR30 Series
- No. of Outputs: 1 Output
- Output Power Max: 30W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Input Voltage AC Max: 264VAC
- Input Voltage AC Min: 85VAC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 32.05 € |
| Current stock | 50+ |
| Lead time | 30 days |
**5-60 Watts** xppower.com ## **DNR Series** - Rugged Design for Industrial Applications - Up to 89% Efficiency - Full Power to +60 °C - Wide Adjustment Range - DC OK 24 V Models - DC Standby Versions - 3 Year Warranty ## ~~**Specification**~~ ## **Input** - Input Voltage • 90-264 VAC, 120-375 VDC (DNR05/10/18) 85-264 VAC, 90-375 VDC (DNR30/60) - Input Frequency • 47-63 Hz Input Current • See tables Inrush Current • 5-18 W: 15/30 A at 115/230 VAC 30 W: 20/40 A at 115/230 VAC 60 W: 30/60 A at 115/230 VAC - Power Factor • EN61000-3-2, class A Earth Leakage Current • 0.8 mA max Input Protection • Internal fuse T2A, 250 VAC fitted in line ## **Output** - Output Voltage • See tables Output Voltage Trim • See tables Initial Set Accuracy • ±1% Minimum Load • No minimum load required Start Up Delay • <1 s (may increase at low temperature extremes) - Start Up Rise Time • <150 ms Hold Up Time • 30/130 ms at 115/230 VAC (DNR05) 25/100 ms at 115/230 VAC (DNR10) 20/75 ms at 115/230 VAC (DNR18) 20/30 ms at 115/230 VAC (DNR30) 20/30 ms at 115/230 VAC DNR60) - Line Regulation • 5-18 W: ±1.0% max 30-60 W: ±0.5% max - Load Regulation • 5-18 W: ±2.0% max 30-60 W: ±0.5% max - Parallel Operation • Redundancy module DPM10 available for load currents up to 10 A (not with standby system), contact sales - Transient Response • 4% max deviation recovery to within 1% in 2 ms for a 50% load change - Ripple & Noise • 50 mV pk-pk, 20 MHz bandwidth (may increase at low temperature extremes) - Overvoltage Protection • Output clamps at 120-145% Vnom, auto recovery - Overload Protection • 110-165% constant current (DNR05-18) 105-150% power limited (DNR30/60) Short Circuit Protection • Power limited, auto recovery Temperature • ±0.03%/°C Coefficient ## **Safety** - Safety Approvals • CE & UKCA meets all applicable directives & legislation ## **General** - Efficiency • See tables Isolation • 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground - Switching Frequency • 132 KHz typical, 55-90 kHz (DNR60) Signals • DC ON indicator LED Green: All models DC LOW indicator LED Red: 5-18 W models DC OK: 24 V 30-60 W models DC OK: All standby models - MTBF • 800 kHrs typical Bellcore, Issue 6 at +40 °C, GB (DNR05/10/18), 530 kHrs typical Bellcore, Issue 6 at +40 °C, GB (DNR30/60) - DC ON indicator LED Green: All models DC LOW indicator LED Red: 5-18 W models DC OK: 24 V 30-60 W models DC OK: All standby models - DIN Rail • Compatible with TS35/7.5 or TS35/15 ## **Environmental** - Operating Temperature • -20 °C to +70 °C (DNR05/10/18) -40 °C to +70 °C, start up at -35 °C (DNR30/60), all units derate linearly from 60 °C (see derating curves) - Cooling • Convection-cooled with 25mm free space all sides - Operating Altitude • 5000m Operating Humidity • 20-95% RH, non-condensing Storage Temperature • -25 °C to +85 °C (DNR05/10/18) -40 °C to +85 °C (DNR30/60) - Shock • 15 g, 11 ms, X, Y & Z axis, 3 shocks/axis in both directions - Vibration • 2 g, 10 Hz to 500 Hz, along X, Y & Z axis, 60 mins/axis, mounted on rail ## **EMC & Safety** - Emissions • EN55022, level B conducted & radiated Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 4, Perf Criteria A Radiated Immunity • EN61000-4-3, level 3, Perf Criteria A EFT/Burst • EN61000-4-4, level 4, Perf Criteria A Surge • EN61000-4-5, installation class 3, Perf Criteria A - Conducted Immunity • EN61000-4-6, level 3, Perf Criteria A Magnetic Field • EN61000-4-8, level 4 Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B - Safety Approvals • EN62368-1, UL508 Pollution Degree 2, UL1310 class 2 power recognised. See note 3 & ratings table, UL62368-1, cUL62368-1 Overvoltage Category II, UL508 Overvoltage Category III, ANSI/ISA 12.12.01. Class 1, Division 2 Groups A,B,C and D DNR30 & DNR60: SEMI F47 . ## ~~**Models and Ratings**~~ ## **DNR05-60** |Output<br>Voltage|Input Current(typ.)|Input Current(typ.)|Output<br>Voltage Trim|Output Current|Efficiency (typ.)|Model Number<br>~~XP |~~| |---|---|---|---|---|---|---| ||115 VAC|230 VAC||||| |5 V|0.12 A|0.08 A|4.50-5.75 V|1.000 A|69%|DNR05US05<br>~~XP |~~| |12 V|0.12 A|0.08 A|10.80-13.80 V|0.420 A|72%|DNR05US12<br>~~XP |~~| |15 V|0.12 A|0.08 A|13.50-17.25 V|0.340 A|72%|DNR05US15<br>~~XP |~~| |24 V|0.12 A|0.08 A|21.60-28.80 V|0.210 A|72%|DNR05US24<br>~~XP |~~| |5 V|0.20 A|0.13 A|4.50-5.75 V|2.000 A|73%|DNR10US05<br>~~XP |~~| |12 V|0.20 A|0.13 A|10.80-13.80 V|0.840 A|75%|DNR10US12<br>~~XP | ~~| |15 V|0.20 A|0.13 A|13.50-17.25 V|0.670 A|76%|DNR10US15| |24 V|0.20 A|0.13 A|21.60-28.80 V|0.420 A|76%|DNR10US24| |5 V|0.36 A|0.21 A|4.50-5.75 V|3.000 A|75%|DNR18US05| |12 V|0.36 A|0.21 A|10.80-13.80 V|1.500 A|77%|DNR18US12| |15 V|0.36 A|0.21 A|13.50-17.25 V|1.200 A|77%|DNR18US15| |24 V|0.36 A|0.21 A|21.60-28.80 V|0.750 A|77%|DNR18US24| |5 V|0.56 A|0.33 A|5.00-5.50 V|6.000 A|79%|DNR30US05(2,3)| |12 V|0.56 A|0.33 A|12.00-14.00 V|2.500 A|84%|DNR30US12(2,3)| |24 V|0.56 A|0.33 A|24.00-28.00 V|1.250 A|86%|DNR30US24(2,3)| |48 V|0.56 A|0.33 A|48.00-55.00 V|0.625 A|86%|DNR30US48(2,3)| |5 V|1.10 A|0.59 A|5.00-5.50 V|10.000 A|79%|DNR60US05(2,3)| |12 V|1.10 A|0.59 A|12.00-14.00 V|5.000 A|86%|DNR60US12(2,3)| |24 V|1.10 A|0.59 A|24.00-28.00 V|2.500 A|89%|DNR60US24(2,3)| |48 V|1.10 A|0.59 A|48.00-55.00 V|1.250 A|89 %|DNR60US48(2,3)| ## ~~**Notes**~~ _1. 30-60 W models are suitable for battery-charging applications. Available for OEM quantities, contact sales._ _2. Approved to UL1310, but 5 & 12 V not Class 2 Power recognised._ _3. SEMI F47 compliant._ ## ~~**Derating Curves**~~ **==> picture [350 x 288] intentionally omitted <==** **----- Start of picture text -----**<br> ,<br>DNR05-18 W Models 100 A<br>a<br>80 PoP NN<br>a Qe<br>60 aQe<br>a<br>40 QOa Qs ee<br>20 Poa Qe ss<br>0 po<br>-20 0 10 20 30 40 50 60 70<br>DNR30-60 W Models 100 PoPe<br>80 PoNN<br>Po<br>60 aa QQ<br>40 a GG<br>a<br>20 Po<br>Po<br>0 a Qs<br>-40 0 10 20 30 40 50 60 70<br>Ambient Temp (˚C)<br>Load (%)<br>Load (%)<br>**----- End of picture text -----**<br> **DNR05-60** ## ~~**Mechanical Details**~~ **DNR05/10/18 W Models** **==> picture [243 x 216] intentionally omitted <==** **----- Start of picture text -----**<br> 0.89<br>4.53 (115.0)<br>(22.5)<br>2 1<br>-V +V<br>DC<br>Sem Output NE<br>O DC LO<br>3.48 ON<br>(88.5) ( @<br>\<br>Voltage<br>Trim<br>N L<br>1 3<br>e—| | !<br>AC Input<br>**----- End of picture text -----**<br> ## ~~**Notes**~~ 1. All dimensions in inches (mm). 2. Weight 0.33 lb (150 g) approx. 3. Tolerance: ±0.02 (0.5) maximum. 4. Connection screw maximum torque: Input: 9 lbs-in (1.0 Nm), Output: 5.5 lbs-in (0.6 Nm) |DNR05, 10, 18 Connections|DNR05, 10, 18 Connections|DNR05, 10, 18 Connections| |---|---|---| |Conn|Pin|Designation| |AC<br>Input|1|Ground| ||2|Neutral| ||3|Line| |DC<br>Output|1|Positive| ||2|Negative| ## **30/60 W Models** **==> picture [525 x 301] intentionally omitted <==** **----- Start of picture text -----**<br> 1.59<br>4.53 (115.0)<br>(40.5)<br>5 1<br>-V -V +V +V DC<br>OK<br>DC Output<br>aii<br>Voltage<br>Trim<br>3.60 |<br>(90.0)<br>ON<br>N L<br>1 3<br>eee] | W llllanaeenegennagnnr DNR30/60 Connections<br>AC Input Conn Pin Designation<br>1 Ground<br>AC<br>2 Neutral<br>Input 3 Line<br>1 DC OK*<br>2 Positive<br>DC<br>3 Positive<br>Notes Output 4 Negative<br>1. All dimensions in inches (mm). 2. Weight 0.8 lb (350 g) approx. [|e ©@] | | PUB 4. Connection screw maximum torque: Input: 9 lbs-in (1.0 Nm), Output: 5.5 lbs-in (0.6 Nm) AAHAHAH | _ 5 Negative<br>3. Tolerance: ±0.02 (0.5) maximum. * 24 V and standby models only.<br>**----- End of picture text -----**<br> **DNR05-60** ~~**Standby Versions**~~ **==> picture [523 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> 5 [ eee@4]] 1 Maximum current drain from battery by PSU when inactive 22 mA<br>-V -V +V +V DC +V<br>OK DNR30/60 Connections<br>DC Output +V Conn Pin Designation<br>DC OK 1 Ground<br>Voltage AC Input 2 Neutral<br>Trim 3 Line<br>D1 Relay 1 DC OK<br>Control<br>e.g. IN4001 2 Positive<br>C e LOAD DC Output 3 Positive<br>ON 4 Negative<br>5 Negative<br>Fuse<br>Notes<br>1. With AC in, unit provides power to the load and to charge the<br>-V Lead battery. The DC OK signal acts by sensing a voltage on +V and<br>Acid holds the relay closed.<br>Battery<br>2. With loss of AC in, battery voltage is present on +V. DC OK<br>© N L<br>-V signal holds the relay closed. Battery supplies power to the load.<br>1 3 3. As the battery discharges, its voltage falls. When this falls below<br>[ |e ee] J<br>DNR30/60 connection for DC the level shown in the table below the DC OK signal switches off<br>AC Input standby system applications to allow the relay to open to disconnect and protect the battery.<br>Coil<br>**----- End of picture text -----**<br> |Output Set Voltages For StandbyVersions|Output Set Voltages For StandbyVersions|Output Set Voltages For StandbyVersions|Output Set Voltages For StandbyVersions|Output Set Voltages For StandbyVersions| |---|---|---|---|---| |Model(1,3)|Voltage|Current|DC OK Signal Off|Efficiency| |DNR30US12_#_|13.6 V|2.20 A|10.30-11.30 V|84%| |DNR30US24_#_|27.2 V|1.10 A|21.10-22.10 V|86%| |DNR30US48_#_|54.5 V|0.55 A|42.70-43.70 V|86%| |DNR60US12_#_(2)|13.6 V|4.40 A|10.30-11.30 V|86%| |DNR60US24_#_|27.2 V|2.20 A|21.10-22.10 V|89%| |DNR60US48_#_|54.5 V|1.10 A|42.70-43.70 V|89%| ## ~~**Notes**~~ 1. Suffix # indicates standby version. 3. _Available for OEM quantities, contact sales._ 2. Not UL1310 approved. ## ~~**DC OK**~~ ## **30/60 W Models** Output good = 24 V Output not good = 0 V **==> picture [314 x 149] intentionally omitted <==** **----- Start of picture text -----**<br> RL > 700Ω<br>©) N/O DCOK<br>DCOK N/C<br>22 K<br>0.5 W<br>5.1 V<br>-Vout E |©) Common -Vout 0.3 W<br>Example using external relay Example using external components<br>to create volt-free contact to create TTL signal<br>oil<br>CC<br>**----- End of picture text -----**<br> Standard on 24 V models, 30-60 W only. 17 Aug 2022
Updated at June 4, 2026
XP Power is a globally recognized leader in the design and manufacture of critical power solutions for the electronics industry. With a steadfast commitment to total quality and in-house engineering expertise, the company delivers highly reliable components that support complex applications across the industrial, healthcare, and technology sectors. Their extensive manufacturing capabilities provide engineers with a broad and dependable source for innovative power products. Our extensive portfolio of XP Power components is heavily focused on robust power and line protection. The core of this offering features a vast selection of high-performance AC/DC converters, designed to meet the rigorous efficiency and footprint demands of modern electronic systems. Complementing these are numerous reliable DC/DC converters, providing versatile options for precise voltage regulation and seamless system integration. Beyond their primary power conversion ranges, XP Power manufactures specialized components to address specific design challenges. Our selection includes essential passive components, such as power line filters for effective EMC and RFI suppression, ensuring signal integrity and strict regulatory compliance. Additionally, we provide dedicated AC/DC LED power supplies tailored for reliable, long-lasting performance in advanced commercial and industrial lighting applications.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →