- Manufacturer: STATUS
- Product type: Digital Panel Meters
- No. of Digits / Alpha:6; Meter Function:Temperature; Meter Range:-270°C to +2300°C; Digit Height:15.8mm; Panel Cutout Height:-; Panel Cutout Wid; Available until stocks are exhausted
- SVHC: No SVHC (04-Feb-2026)
- Meter Range: -270°C to +2300°C
- Digit Height: 15.8mm
- Product Range: DM670TM Series
- Meter Function: Temperature
- Panel Cutout Width: -
- Supply Voltage Max: 3.6V
- Supply Voltage Min: -
- Panel Cutout Height: -
- No. of Digits / Alpha: 6
- Operating Temperature Max: 70°C
- Operating Temperature Min: -30°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 105.19 € |
| Current stock | 10+ |
| Lead time | 30 days |
DM670TM FIELD/WALL MOUNTED TEMPERATURE DISPLAY - **UNIVERSAL RTD OR THERMOCOUPLE INPUT** **BATTERY POWERED, USB AND NFC INTERFACE** **DUAL RELAYS, MAX/MIN INFORMATION** **USER-SET DISPLAY MESSAGING** - **5000 POINT LOGGER* (USB or COMPATIBLE ANDROID DEVICE)** ## **INTRODUCTION** The DM670TM series of battery powered indicators accept RTD or Thermocouple temperature sensors and display the sensor temperature in °C or °F on a 6-digit LCD display. The instrument offers an advanced display mode allowing the user to also display one or two (1 to 32) character messages. Additional to the messages, the user may select an alert-event to occur when the temperature is within a band. The two changeover relays can be used together with the messaging and alert to provide switching at userset switch points. In addition to this, on-board datalogging is also available to record process details up to 5000 points. ## **FEATURE HIGHLIGHTS** ## **DUAL RELAYS** The instrument is equipped with 2 volt-free changeover-type relays, operating independently. The user may select one of seven actions, including deviation, latched or non-latched operation, with fully adjustable set-point and hysteresis. The Relays may be turned off if not required to extend battery life. An option is provided to trigger an alert-event when a relay contact is on. **DATA LOGGING FUNCTION** (See Logger* entries, check website for latest Android version compatibility) DM670TM also provides a powerful data logging function. The log points can be set up to 5000 points, each point is time and date-stamped together with temperature and relay state information. The log rate is selectable in steps. The start of log can be delayed if required. Either fixed or rolling logs may be performed. Two methods of reading the log are available. The USB configuration reads the log and allows the user to save to a text file for export to other programmes. While the NFC android interface allows data transfer to compatible android phones or tablets by using the downloadable App, the data can be graphed and forwarded by email, Bluetooth etc. The NFC interface is also capable of starting a new log with different log period and modes. ## **BATTERY POWERED** The instrument is powered by a single 3.6 V lithium battery. The battery life is dependent on the number of active features such as the relay contacts and alert LED. Battery life 1 year minimum (longer depending on options selected) ## **REAL-TIME CLOCK** Date and time-stamped maximum, minimum and average temperature values, as well as relay on and relay off data, is recorded and can be displayed along with the current time and date. The Real Time Clock is also used to record the data logged points. **==> picture [492 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> D2595-01-06, Page 1 of 5<br>STATUS<br>**----- End of picture text -----**<br> D2595-01-06, Page 1 of 5 DM670TM FIELD/WALL MOUNTED TEMPERATURE DISPLAY |**INPUT**|**INPUT**|**INPUT**|**INPUTSPECIFICATIONS @20°C**| |---|---|---|---| |**RTD (3 Wire)**|||| |**Type**|**Range**||**Accuracy/stability**| |Pt100 (IEC)|(-200 to 850)°C||| |Ni100|(-60 to180)°C||±0.2°C ±0.05% of reading| |Ni120|(-70 to180)°C||(plus, sensor error)| |Cu53|(-40 to180)°C||| |Cu100|(-80 to260)°C||| |Thermal drift|0°C at20°C||Typically, 0.01 Ω/°C| ||||Example Pt100 0.03°C/°C| ||||| |**INPUT**|**INPUT**|**INPUT**|**INPUTSPECIFICATIONS @20°C**| |**Thermocouple**|||| |**Type**|**Range**||**Accuracy/stability**| |K|(-150 to1370)°C||±0.1% of full scale ±0.5°C| |J|(-200 to1200)°C||± CJ error| |N|(-270 to1300)°C||(plus, sensor error)| |E|(-260 to1000)°C||| |T|(-270 to 400) °C||±0.2% of full scale ±0.5°C| ||||± CJ error| ||||(plus, sensorerror)| |R|(0 to1760)°C||±0.1% of full scale ±0.5°C| |S|(0 to 1760)°C||± CJ error| ||||(plus, sensor error) over range (800| ||||to1760)°C| |L|(-200 to 900)°C||| |U|(0 to 600)°C||±0.1% of full scale ±0.5°C| |B|(0 to1820)°C||± CJ error| |C|(0 to2300)°C||(plus, sensor error)| |D|(0 to2300)°C||| |G|(0 to2300)°C||| |Thermal drift|0°C at20°C||Typically, ±5 uV/°C| ||||| |**CASE SENSOR/COLD JUNCTION (CJ)**||**CASE SENSOR/COLD JUNCTION (CJ)**|**CASE SENSOR/COLD JUNCTION (CJ)SPECIFICATIONS @20°C**| |**Type**|**Range**||**Accuracy/stability**| |Thermistor 10K Beta 3380|(-30 to 70)°C||±0.2°C| |Thermal drift|0°C at 20°C||±0.05°C/°C| ||||| |**DISPLAY**|||| |**Type/options/function**|**Description**||| |Display height|15.8 mm non-backlit||| |Display information options|6 digits 14 segment input value plus “Warning”,” Transmit”, “NFC”,||| |Some information is displayed|“USB”, “Log”, “Battery” icons, 8 segment log volume indicators.||“USB”, “Log”, “Battery” icons, 8 segment log volume indicators.| |scrolling.|Maximum, minimum, average *1. Date and time,||Maximum, minimum, average *1. Date and time,| ||case temperature. Custom messages for visual alarms/information.||| ||Relay condition.||| |High intensity LED|Alarmand warning options||| |*1 Rolling average logisindependent ofdata logging|||| ||||| |**RELAYS**|||| |**Relay 1and Relay 2**|||| |**Type/options/function**|**Description**||| |2 x independentrelays|Single pole changeover(common, N/o, N/c)||| |Rating|48 VDC maximum @ 1 A (5 mA minimum)||| ||28 VACRMSmaximum@1 A||| D2595-01-06, Page 2 of 5 DM670TM FIELD/WALL MOUNTED TEMPERATURE DISPLAY |**USB CONFIGURATION USER INTERFACE (USB SpeedLink software)**<br>~~i~~|**USB CONFIGURATION USER INTERFACE (USB SpeedLink software)**<br>~~i~~|**USB CONFIGURATION USER INTERFACE (USB SpeedLink software)**<br>~~i~~| |---|---|---| |**Type/options/function**<br>~~CO~~|**Description**<br>~~CO~~|**Notes**<br>~~CO~~| |Configuration hardware<br>~~CO~~|USB Mini B port<br>~~CO~~|Cable not included<br>~~CO~~| |Configuration software<br>~~CO~~<br>~~CO~~|USBSpeedLink<br>~~CO~~<br>~~CO~~|Download www.status.co.uk<br>~~CO~~<br>~~CO~~| |Operating system<br>~~CO~~|Microsoft Windows<br>~~CO~~<br>~~ee~~|Win 7 or later<br>~~CO~~| |Sensor configuration<br>~~CO~~<br>~~ee~~|Select sensor type<br>Trimsensoroffset<br>~~CO~~<br>~~ee~~<br>~~ee~~|TC options/RTD options<br>±10°C, ±18°F<br>~~CO~~<br>~~ee~~| |Display configuration<br>~~ee~~|Display mode<br>Set display units<br>Display offset for zero (-270 to<br>5000)°C range<br>Rolling average<br>~~ee~~<br>~~ee~~|Basic or advanced<br>°C or °F<br>Differential from set-point is<br>displayed<br>Count/updaterate<br>~~ee~~| |Pre-set sensorto setpoint<br>~~a~~|Locks display value<br>~~C~~|Fordiagnostics<br>~~C~~| |Advanced display mode *1|Temperature and/or message A, B (32 character) and/or alert LED<br>flash.<br>Update every 5 seconds/alternates between messageAandB|| |Basic displaymode<br>~~a~~|Temperature|| |Display<br>Pre-set display messages<br>~~a~~|Seven custom messages<br>Eight user-adjustable<br>temperature bands|Message A and message B<br>options| |LED alert<br>~~a~~|Eight user-adjustable<br>temperature bands|Alert LED flash| |Warning symbol<br>~~a~~|Out of range<br>Open circuit<br>Low battery level|Warning symbol will flash on LCD<br>display| |Batterymonitor<br>~~CO~~|AlertLEDplusmessage<br>~~CO~~|Relay option<br>~~CO~~| |Logger*<br>~~CO~~|Set device passkey number<br>Clear/start new log<br>Android compatibility<br>~~CO~~|Device passkey is used to protect the<br>NFC interface.<br>V (5-11), V (5-latest, see website)<br>~~CO~~| |Other device options|Synchronise clock<br>Write tag/contact address<br>Read/reset maximum and<br>minimumvalues|| |Relay control|Name(s)<br>Action<br>Set-point<br>Dead band<br>Latch|10 character<br>High/low/band/low battery<br>°C °F<br>°C °F<br>On/Off| |Live data|Read sensor temperature<br>Read cold junction<br>Relay1state.Relay2state|°C °F<br>Internal case temperature| |*1 Advanced displayreverts to basic display below-5°C case temperature.<br>~~pC~~||| ~~pC~~ *1 Advanced display reverts to basic display below -5°C case temperature. ## **USB LOGGER USER INTERFACE (USB LogLink software)** |**USB LOGGER USER INTERFACE (USB LogLink software)**|**USB LOGGER USER INTERFACE (USB LogLink software)**|**USB LOGGER USER INTERFACE (USB LogLink software)**| |---|---|---| |**Type/options/function**|**Description**|**Notes**| |Logger hardware|USB Mini B|| |Logger software|USBLogLink|Download from www.status.co.uk| |Operating system|Microsoft Windows|Win 7 or later| |Logger*<br>For USB logging,<br>Up to 5000 log points|Start/set log parameters|Interval/rate/(delay) start<br>number ofpoints/rollingor fixed log| ||Read log parameters|| ||Stop/start new log<br>Synchronise device clock<br>Reset maximum and minimum<br>Synchronise/read clock<br>Android compatibility|V (5-11), V (5-latest see website)| ||View log data/graphlog data|Save data to CSVfile| D2595-01-06, Page 3 of 5 DM670TM FIELD/WALL MOUNTED TEMPERATURE DISPLAY ## **NFC ENABLED ANDROID DEVICE REQUIREMENTS** **==> picture [461 x 47] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||| |---|---|---|---|---|---|---|---|---| |Tag Type|NFC Forum Tag Type 4 (max capacity|65536 Bytes)| |RF Interface|ISO/IEC 14443 Type B Compliant|(13.56|MHz)| |Android|device|Compatibility|to read|NFC Tag|type 4 to full|capacity|65536|bytes| |Note: If the Android|device|cannot read full|bytes|the maximum number of log|points|will|be reduced.| **----- End of picture text -----**<br> **==> picture [466 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||||| |---|---|---|---|---|---|---|---|---| |NFC LOGGER USER INTERFACE (NFC LogLink software)| |ANDROID| |Type/options/function|Description|Notes| |Logger software|NFC LogLink|Download from www.status.co.uk| |Operating system|Android Kitkat or later|NFC enabled| |Logger*|Start/set|log|parameters|Interval/rate/(delay) start| |Android version 5 to 11,|Read|log|parameters|number of points/rolling or fixed log| |up to 5000 log points|Stop and start new log, Synchronise, read clock| |Android version 5 to latest-|Reset maximum and minimum| |see website,|View|log|data/graph log|data|Save|data|to|text file| |up to 2500 log|points|Transfer data|via|email|etc.|Standard Android functions| **----- End of picture text -----**<br> **PUSH BUTTON USER INTERFACE** **==> picture [416 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |Button|Description|Notes| |Maximum and minimum|Display/ display and reset|Time stamp option| |Rolling average option|Number and rate options| |Relay|Display relay configuration|Time stamp option| |Reset latched relay| |Set point adjustment is not possible using front panel buttons, USBSpeedLink required| |Buttons can be locked out in USBSpeedLink| **----- End of picture text -----**<br> **==> picture [405 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |GENERAL| |Function|Description| |Update rate|5|seconds| |Relay response time|< 10 seconds| |Battery|1 x (AA 3.6 V lithium)| |Battery life|1 year minimum (longer depending on options selected)| |Clock accuracy|±2 seconds|per month typically| **----- End of picture text -----**<br> ## **ENVIRONMENTAL** **==> picture [429 x 59] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||||| |---|---|---|---|---|---|---|---| |Function|Description| |Ambient|temperature|Operating/storage|(-30|to 70) °C| |Ambient humidity|Operating/storage|(10|to|90)|%RH non-condensing| |Protection|IP65,|cable/probe|entries must|be|sealed|to IP65|to maintain| |USB configuration ambient|(10|to|30) °C| **----- End of picture text -----**<br> ## **MECHANICAL** **==> picture [378 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||| |---|---|---|---|---|---|---| |Enclosure|Stainless steel, various mounting options| |Case entries|2 x M16 female|thread,|one|blanking|plug|supplied| |Front bezel diameter|113 mm| |Weight (approximate)|540 g| |Input sensor|Two-part screw connector| |Output relays|2 x Two-part screw connectors| |USB connection|USB Mini B socket| **----- End of picture text -----**<br> D2595-01-06, Page 4 of 5 DM670TM FIELD/WALL MOUNTED TEMPERATURE DISPLAY **APPROVALS** EMC BS EN 61326: Note - Sensor input wires to be less than 3 m to comply Ingress protection BS EN 60529 RoHS Directives 2 & 3 2011/65/EU & EU 2015/863, and the UK designated standards ## **ORDER CODE** **DM670TM /** Choose case type from below **Case option** Cable and probe entries: M16 Double side entry **I** Double rear entry **J** Panel mount **K** 100 mm diameter cut-out to panel Wall mount **L** Example: - for double side entry **DM670TM/I** **ACCESSORIES** Configuration software USBSpeedLink free of charge from www.status.co.uk USB logging software USBLogLink free of charge from www.status.co.uk NFC logging software NFCLogLink free of charge from www.status.co.uk USB programming lead USB programming lead, part number 42-200-0001-01 Battery 3.6 V lithium Part number 28-302-0036-00 Probe options Refer to www.status.co.uk To maintain full accuracy annual calibration is required contact support@status.co.uk for details. The data in this document is subject to change. Status Instruments assumes no responsibility for errors. Status Instruments Ltd Tel: +44 (0)1684 296818 Status Business Park Fax: +44 (0)1684 293746 Gannaway Lane, Tewkesbury Email: sales@status.co.uk Gloucestershire, UK Website: www.status.co.uk GL20 8FD D2595-01-06, Page 5 of 5
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →